Yale Insulin Drip Protocol (Target 100 139) PDF
Yale Insulin Drip Protocol (Target 100 139) PDF
Yale Insulin Drip Protocol (Target 100 139) PDF
If BG 50-74 mg/dL:
D/C INSULIN DRIP
If symptomatic (or unable to assess), give 1 Amp (25 g) D50 IV; recheck BG q 15 minutes
If asymptomatic, give 1/2 Amp (12.5 g) D50 IV or 8 ounces Juice; recheck BG q 15-30 minutes
When BG 100 mg/dL, wait 1 hour , then restart drip at 75% of original rate
Changing the Insulin Drip Rate (contd.)
If BG 75 mg/dL:
STEP 1: Determine the CURRENT BG LEVEL - identifies a COLUMN in the table:
BG 75-99 mg/dL
BG 100-139 mg/dL
BG 140-199 mg/dL
BG 200 mg/dL
STEP 2: Determine the RATE OF CHANGE from the prior BG level - identifies a CELL in the table - Then move right for INSTRUCTIONS:
[Note: If the last BG was measured 2-4 hrs before the current BG, calculate the hourly rate of change. Example: If the BG at 2PM was 150 mg/dL and
the BG at 4PM is now 120 mg/dL, the total change over 2 hours is -30 mg/dL; however, the hourly change is 30 mg/dL 2 hours = -15 mg/dL/hr.]
BG 75-99 mg/dL
BG 100-139 mg/dL
BG by > 25 mg/dL/hr
BG
BG 140-199 mg/dL
BG 200 mg/dL
INSTRUCTIONS*
BG by > 50 mg/dL/hr
BG
DRIP by 2
BG by 1-50 mg/dL/hr
BG UNCHANGED
OR
OR
DRIP by
BG UNCHANGED
BG by 1-25 mg/dL/hr
BG by 1-25 mg/dL/hr,
BG UNCHANGED, OR
BG by 1-25 mg/dL/hr
BG by 1-50 mg/dL/hr
BG by 26-75 mg/dL/hr
NO DRIP CHANGE
BG by 26-50 mg/dL/hr
BG by 51-75 mg/dL/hr
BG by 76-100 mg/dL/hr
DRIP by
BG by > 50 mg/dL/hr
BG by > 75 mg/dL/hr
BG UNCHANGED
OR
BG by 1-25 mg/dL/hr
BG by > 25 mg/dL/hr
see below**
**D/C INSULIN DRIP; BG
= Rate Change
(U/hr)
0.5
1
1.5
2
3
4
5
2 = 2X Rate Change
(U/hr)
1
2
3
4
6
8
10 (Consult MD)