Dilution Rate
1 Liter Envacol into 40 Liter water, applied for approx. 10 MT coal.
Required Equipment
- Mixing Tank, capacity of 5,000 – 10,000 Liter.
- Pumping Unit, any acceptable brand with output 3-6 Bar.
- Piping, diameter 1 in, various pipe material can be used depend on client approval.
- Nozzle, depends on desired flow rate output.
Example :
• Treatment location : conveyor with loading rate 500 MT/hour.
• Envacol standard dosage : 1 Liter Envacol for 10 MT coal on dilution rate of 1:40.
• Required pumping unit flow rate : 600 x 40/10 = 2,000 liter/hour.
• With maintaining pump pressure on 3 Bar, the nozzle type can be specifically defined
depends on how many nozzles can be installed suitably. 3 nozzles with 800 liter/hour
flow rate or 4 nozzles with 600 liter/hour flow rate can be used on this case.
• Daily usage base with assumption on 24 hours non stop loading operation, approx.
1,170 liter of Envacol diluted into 46,830 liter of water will be required for this
treatment or approx. 50 liter of Envacol and 1,950 liter of water will be required on 1
hour operation.
circulation process
CHEMICAL
DRUM
PUMPING UNIT
Dilution Procedure
- Use clean water (normal PH), avoid using sea water.
- Fill the mixing tank with Envacol first following with water.
- Start circulating procedure approx 5 minute.
- Stop circulation process and prepare for spraying operation.