Cascade 5700 5.7" Panel Mount HMI Specification: Model: FBDA9031-50
Cascade 5700 5.7" Panel Mount HMI Specification: Model: FBDA9031-50
Cascade 5700 5.7" Panel Mount HMI Specification: Model: FBDA9031-50
1. General Specifications
Table 1
Parameter Specification Unit
Screen Size 5.7 (Diagonal) inch
Display Format 640 RGB x 480 pixels
Active Area 115.2 (W) x 86.4 (H) mm
Pixel Size 120 (W) x 120 (H) μm
Colors 262,144 (18-bit) colors
Brightness 350 (Maximum) cd/m2
Touch Screen 4-Wire Resistive ─
Outline Dimensions 168 (W) x 134 (H) x 32 (D) mm
Weight TBD g
Viewing Angle 6 o’clock ─
Speaker 2 watts
Processor ARM920T ─
Speed 533 MHz
Flash Memory 64 MB
Operating System Win CE 5.0 ─
Operating Temperature 0 to 50 °C
Storage Temperature -40 to 85 °C
3. External Connectors
3.1. RS-485
Tied to UART2 on the processor.
Port is half-duplex.
Connector is standard RJ-11 (phone jack).
Table 3
Pin No. Symbol Description Remarks
1 Shield Cable shield Optional
2 A RS-485 A Signal Note 1
3 GND
4 GND
5 B RS-485 B Signal Note 1
6 GND
Note 1: The Request To Send (RTS) line is used for flow control. When RTS is
high the unit is transmitting; when RTS is low the unit is receiving.
3.2. Ethernet
Connector is standard RJ-45.
Pinout follows standard Ethernet pinout.
Ethernet port is 10/100.
Power over Ethernet (POE) is not supported.
4. Internal Connectors
4.1. Connector Layout
Table 4
Connector
Designation Description
J13 Microphone
J12 Speaker
CON1 JTAG
J15
Table 5
Pin No. Symbol Description Remarks
1 3.3V Power
2 3.3V Power
3 nTRST TAP Reset Connected to nTRST on processor
4 GND Ground
5 TDI TAP Data Input Connected to TDI on processor
6 GND Ground
7 TMS TAP Mode Select Connected to TMS on processor
8 GND Ground
9 TCK TAP Clock Connected to TCK on processor
10 GND Ground
11 N/C No connect
12 GND Ground
13 TDO TAP Data Output Connected to TDO on processor
14 GND Ground
15 RESET Reset Drive low to reset entire system
16 GND Ground
17 N/C No connect
18 GND Ground
19 N/C No connect
20 GND Ground
You will need to an RS-232 serial cable between your PC and the Cascade
4300. The RS-232 port is available on an internal connector on the Cascade
4300 PCB. You will also need a USB cable, but it should not be attached at
the beginning of the procedure. The USB device port is located just below
the SD card slot. The connector type is mini-USB Type B.
Once the RS-232 cable is in place, insert the Cascade 4300 CD in your PC
and follow these steps:
3) Go to the Configuration->Options menu. Set the COM port. Set the baud
rate to 115200.
12700 Park Central, Suite 750, Dallas, TX 75251 contact@OcularLcd.com
Tel: 972-437-3888 Fax: 972-437- 2562 www.OcularLcd.com Page 7 of 12
FBDA9031-50
Cascade 5700 HMI Specification
Note: DNW only supports COM1 through COM4. If you are using a higher COM port,
you can use any terminal program for the serial communications part of this
procedure.
Note: If you want DNW to save your options as the default settings, copy the entire
Image Downloader folder to your hard drive and run DNW from there.
4) Set the USB Port Download Address to 0x30200000 (this should be the
default) and select OK.
8) Connect the USB cable. The title bar of DNW should show [USB:OK].
Note: The first time you attach the USB cable you will be prompted to install the USB
driver. Navigate to the Cascade 4300 CD and select the Image Downloader folder.
When prompted, choose the first entry in the list. When prompted for a CD, navigate
again to the Image Downloader folder.
10) Press 6 to set the Program disk image into SmartMedia card to Enabled.
Note: The NK.bin file that shipped with your unit is located on the Cascade 4300 CD
at \OS Image\Default NK.bin.
15) During the download you may see messages stating that some sectors
are not writeable. This is normal.
17) Cycle power to the Cascade 4300 to begin running with the new OS
image.
6. Quality Assurance
Table 14
No. Test items Test condition
1 High Temperature Operation Test Ta=60°C Dry 24h
2 Low Temperature Operation Test Cold start @ -20°C
Operational @ 0°C for 24h
3 High Temperature and High Operational @ 60°C 90%RH for
Humidity Operation Test 240h
±8KV (Contact)
4 Electro Static Discharge Test
±15KV (Air)
Sine wave, 10Hz to 50Hz
5 Vibration Test (non-operating) 1.5mm amplitude
3 axis, 2 hours/axis
7. Mechanical Drawing
7.1. Enclosure