Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
100% found this document useful (2 votes)
2K views

CAN Mode 6

It talks about communication system between controllers in the vehicles . CAN is new communication way in the modern vehicles , this manual is importent for technicians , they need it to repair cars problems .

Uploaded by

Abdulbaset Selwy
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
2K views

CAN Mode 6

It talks about communication system between controllers in the vehicles . CAN is new communication way in the modern vehicles , this manual is importent for technicians , they need it to repair cars problems .

Uploaded by

Abdulbaset Selwy
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link

Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Oxygen Sensor Monitor


Bank 1 Sensor 1
01 01 0A Rich to Lean Sensor Threshold Voltage 0.0000 to 7.9900 V 0.122 mv / bit
01 02 0A Lean to Rich Sensor Threshold Voltage 0.0000 to 7.9900 V 0.122 mv / bit
01 03 0A Low Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 04 0A High Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 05 10 Rich to Lean Sensor Switch Time 0.0000 to 65.535 ms 1 ms / bit
01 06 10 Lean to Rich Sensor Switch Time 0.0000 to 65.535 ms 1 ms / bit
01 10 see footnote 1
01 80 2B Rich to Lean Switches Test Results 0 to 65535 switches 1 switch / bit
01 81 2B Lean to Rich Switches Test Results 0 to 65535 switches 1 switch / bit
01 82 20 Rich-Lean Response to Lean-Rich Response Ratio 0.000:1 to 255.996:1 ratio 0.0039 / bit
01 83 0A Low Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 84 0A High Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 85 10 O2 Sensor Rich to Lean Half Period Time 0.0000 to 65535 ms 1 ms / bit
01 86 10 O2 Sensor Lean to Rich Half Period Time 0.0000 to 65535 ms 1 ms / bit
01 87 10 Sum of O2 Sensor L/R and R/L Half Period Times 0.0000 to 65535 ms 1 ms / bit

(3) Difference Between –32768 to +32767


01 88 90 1 ms / bit
Rich-Lean Response and Lean-Rich Response milliseconds
01 89 06 B1S1 WRAF Slow Response 0 to 19.99 raw value 0.000305 / bit
01 8E B1 Absolute Average Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit
01 8F B1 Instantaneous Positive Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit
01 90 B1 Instantaneous Negative Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit

Oxygen Sensor Monitor


Bank 1 Sensor 2
02 05 20 B1S2 rich-lean switch time in fuel cut-off 0.000:1 to 255.99:1 ratio 0.0039 / bit
02 8A 24 Post Catalyst Sensor Open Test 0 to 65535 counts 1 count / bit
02 8B 0A Post Catalyst Sensor Rich Test 0.0000 to 7.9900 V 0.122 mv / bit
02 8C 0A Post Catalyst Sensor Lean Test 0.0000 to 7.9900 V 0.122 mv / bit

Footnotes are explained on the last pages of this document. page 1 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Oxygen Sensor Monitor


Bank 1 Sensor 3
03 8A 24 Post Catalyst Sensor Open Test 0 to 65535 counts 1 count / bit
03 8B 0A Post Catalyst Sensor Rich Test 0.0000 to 7.9900 V 0.122 mv / bit
03 8C 0A Post Catalyst Sensor Lean Test 0.0000 to 7.9900 V 0.122 mv / bit

Oxygen Sensor Monitor


Bank 2 Sensor 1
05 01 0A Rich to Lean Sensor Threshold Voltage 0.0000 to 7.9900 V 0.122 mv / bit
05 02 0A Lean to Rich Sensor Threshold Voltage 0.0000 to 7.9900 V 0.122 mv / bit
05 03 0A Low Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 04 0A High Sensor Voltage For Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 05 10 Rich to Lean Sensor Switch Time 0.0000 to 65535 ms 1 ms / bit
05 06 10 Lean to Rich Sensor Switch Time 0.0000 to 65535 ms 1 ms / bit
05 10 see footnote 1
05 80 2B Rich to Lean Switches Test Results 0 to 65535 switches 1 switch / bit
05 81 2B Lean to Rich Switches Test Results 0 to 65535 switches 1 switch / bit
05 82 20 Rich-Lean Response to Lean-Rich Response Ratio 0:1 to 255.996:1 ratio 0.0039 / bit
05 83 0A Low Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 84 0A High Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 85 10 O2 Sensor Rich to Lean Half Period Time 0.0000 to 65535 ms 1 ms / bit
05 86 10 O2 Sensor Lean to Rich Half Period Time 0.0000 to 65535 ms 1 ms / bit
05 87 10 Sum of O2 Sensor L/R and R/L Half Period Times 0.0000 to 65535 ms 1 ms / bit
Difference Between –32768 to +32767
05 88 90 1 ms / bit
Rich-Lean Response and Lean-Rich Response milliseconds
05 89 06 B2S1 WRAF Slow Response 0 to 19.99 raw value 0.000305 / bit
05 8E B1 Absolute Average Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit
05 8F B1 Instantaneous Positive Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit
05 90 B1 Instantaneous Negative Slope of the O2 Sensor Signal –65536 to +65534 mV/s 2 mV/s per bit

Footnotes are explained on the last pages of this document. page 2 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Oxygen Sensor Monitor


Bank 2 Sensor 2
06 05 20 B2S2 rich-lean switch time in fuel cut-off 0.000:1 to 255.99:1 ratio 0.0039 / bit
06 8A 24 Post Catalyst Sensor Open Test 0 to 65535 counts 1 count / bit
06 8B 0A Post Catalyst Sensor Rich Tests 0.0000 to 7.9900 V 0.122 mv / bit
06 8C 0A Post Catalyst Sensor Lean Tests 0.0000 to 7.9900 V 0.122 mv / bit

Oxygen Sensor Monitor


Bank 2 Sensor 3
07 8A 24 Post Catalyst Sensor Open Tests 0 to 65535 counts 1 count / bit
07 8B 0A Post Catalyst Sensor Rich Tests 0.0000 to 7.9900 V 0.122 mv / bit
07 8C 0A Post Catalyst Sensor Lean Tests 0.0000 to 7.9900 V 0.122 mv / bit

Catalyst Monitor
21 A0 01 Catalyst Test Bank 1 (using OSC normalized ratio units) 0 to +65535 unitless 1 per bit
21 A0 05 Catalyst Test Bank 1 (using OSC normalized ratio units) 0 to 1.999 unitless 0.0000305 / bit
–32768 to +32767
21 A0 90 Catalyst Test Bank 1 (using OSC compensation units) 1 ms / bit
milliseconds
21 A1 01 Catalyst Test Bank 1 (using Catalyst DFCO Exit Test) 0 to +65535 unitless 1 per bit
22 A0 01 Catalyst Test Bank 2 (using OSC compensation units) 0 to +65535 unitless 1 per bit
22 A0 05 Catalyst Test Bank 2 (using OSC normalized ratio units) 0 to 1.999 raw value 0.0000305 / bit
–32768 to +32767
22 A0 90 Catalyst Test Bank 2 (using OSC compensation units) 1 ms / bit
milliseconds
22 A1 01 Catalyst Test Bank 2 (using Catalyst DFCO Exit Test) 0 to +65535 unitless 1 per bit

EGR Bank 1
31 A8 FD EGR Flow Decel Service Test –32.768 to +32.767 kPa 0.001 kPa / bit
31 A9 (6) EGR Flow Quick Test –32.768 to +32.767 kPa 0.001 kPa / bit
FD

Footnotes are explained on the last pages of this document. page 3 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

EVAP Monitor
EVPD = Evap Pressure / Vacuum Decay
(Cap off/gross Leak, large leak)
39 39 see footnote 1
39 3A see footnote 1
39 3B see footnote 2
39 B0 FE Cap Off/gross Leak -8192 to +8191.75 Pa 0.25 Pa / bit
39 B1 32 Large leak 0 to 1.999 inch 0.0000305 / bit

EVAP Monitor (Large) EVPD = Evap Pressure / Vacuum Decay


3A C0 31 EVPD Weak Vacuum Test scaled in liters 0.0 to 65.535 liters 0.001 liters / bit
3A C0 FD EVPD Weak Vacuum Test scaled in kPa –32.768 to +32.767 kPa 0.001 kPa / bit
3A C1 11 EVPD Weak Vacuum Follow-up Test 0.0 to 6553.5 sec 100 milliseconds / bit

EVAP Monitor 0.040" EVPD = Evap Pressure / Vacuum Decay


3B C2 32 EVPD NV 0.040 Test - scaled in inches 0.000 to 1.999 inches 0.0000305 inches / bit
3B C2 B0 EVPD NV 0.040 Test - scaled in percentage slope –100.01 to +100.00% +0.003052 percent / bit

EVPD = Evap Pressure / Vacuum Decay


EVAP Monitor 0.020"
EONV = Engine Off Natural Vacuum
3C C2 B0 EVPD NV 0.020 Test - scaled in percentage slope –100.01 to +100.00% +0.003052 percent / bit
3C C3 B0 EVPD NV 0.020 Test - scaled in percentage slope –100.01 to +100.00% +0.003052 percent / bit
3C C3 32 EVPD NV 0.020 Test - scaled in inches 0.000 to 1.999 inches 0.0000305 inches / bit
3C C8 20 EONV NV 0.020 Test 0.000:1 to 255.996:1 ratio 0.0039 / bit
EONV NV 0.020 Test
3C C8 FD –32.768 to +32.767 kPa 0.001 kPa / bit
(Note: 1 kPa = 4.0146309 inches H2O )
3C C9 20 EONV Vacuum Rezero Test 0.000:1 to 255.996:1 ratio 0.0039 / bit
3C C9 FE Canister Vent Valve 'stuck closed' -8192 to +8191.75 Pa 0.25 Pa / bit
3C CA 24 EONV Fuel Level Rationality Test 0 to 65535 counts 1 count / bit
3C CB 24 EONV Vacuum Rationality Test 0 to 65535 counts 1 count / bit
3C CB FE Canister Purge Valve 'stuck open' -8192 to +8191.75 Pa 0.25 Pa / bit

Footnotes are explained on the last pages of this document. page 4 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Purge Flow Monitor EVPD = Evap Pressure / Vacuum Decay


3D C4 11 EVPD NV Purge Pass Test 0.0 to 6553.5 sec 100 milliseconds / bit
EVPD Purge Vacuum Fail Test
3D C5 FE Note: 1kPa = 0.0040146309 inches H2O vacuum –32.768 to +32.767 inches H2O 0.001 inches H2O / bit
Note: Min Test Limit is set to $8000 if test complete.

3D C6 (5) EVPD Vent Restriction Test 1 0.0 to 6553.5 sec 100 milliseconds / bit
11
EVPD Vent Restriction Test 2 - scaled in kPa.
3D C7 FD 32.768 to +32.767 kPa 0.001 kPa / bit
Note: 1 kPa = 4.0146309 in H2O
3D C7 31 EVPD Vent Restriction Test 2 - scaled in liters 0.0 to 65.535 liters 0.001 liters / bit
3D C8 31 EVPD Vent Restriction Test2 - scaled in liters 0.0 to 65.535 liters 0.001 liters / bit

Oxygen Sensor Heater Monitor


Bank 1 Sensor 1
41 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
41 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
41 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
41 D3 11 Sensor Heater Monitor B1S1 'operative readiness time' 0 to 6553.5 seconds 100ms / bit
41 D4 96 Sensor Heater Monitor B1S1 'tip temperature out of range' -3276.8 to + 3276.7 degC 0.1 degC / bit
–32.768 to +32.767
41 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms

Oxygen Sensor Heater Monitor


Bank 1 Sensor 2
42 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
42 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
42 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
42 D5 14 Sensor Heater Monitor B1S2 ' resistance out of range' 0 to 65535 ohms 1 ohm / bit
–32.768 to +32.767
42 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms

Footnotes are explained on the last pages of this document. page 5 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Oxygen Sensor Heater Monitor


Bank 1 Sensor 3
43 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
43 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
43 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
–32.768 to +32.767
43 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms

Oxygen Sensor Heater Monitor


Bank 2 Sensor 1
45 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
45 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
45 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
45 D3 11 Sensor Heater Monitor B2S1 'operative readiness time' 0 to 6553.5 seconds 100ms / bit
–32.768 to +32.767
45 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms
45 D4 96 Sensor Heater Monitor B2S1 'tip temperature out of range' -3276.8 to + 3276.7 degC 0.1 degC / bit

Oxygen Sensor Heater Monitor


Bank 2 Sensor 2
46 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
46 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
46 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
–32.768 to +32.767
46 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms
46 D5 14 Sensor Heater Monitor B2S2 ' resistance out of range' 0 to 65535 ohms 1 ohm / bit

Footnotes are explained on the last pages of this document. page 6 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Oxygen Sensor Heater Monitor


Bank 2 Sensor 3
47 D0 11 Time to Activity Monitor 0.0 to 6553.5 sec 100 milliseconds / bit
47 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Amperes / bit
47 D2 24 Current Feedback X out of Y Samples Test 0 to 65535 counts 1 count / bit
–32.768 to +32.767
47 D3 84 Heater Resistance Error Test 0.001 Ohm/bit
differential ohms

Secondary AIR monitor


bank 1
71 E0 24 AIR - Bank 1 Test 0 to 65535 counts 1 count / bit
71 E1 FD AIR on - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
71 E2 FD AIR Valve shut - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
71 E3 FD AIR Pump off - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit

Secondary AIR monitor


bank 2
72 E0 24 AIR - Bank 2 Test 0 to 65535 counts 1 count / bit
72 E1 FD AIR on - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E2 FD AIR Valve shut - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E3 FD AIR Pump off - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E4 FD AIR on - pressure differential, between bank 1 and bank 2 –32.768 to +32.767 kPa 0.001 kPa / bit

Misfire Cylinder 1 data

(4) EWMA (Exponentially Weighted Moving Average)


A2 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles

A2 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Footnotes are explained on the last pages of this document. page 7 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Misfire Cylinder 2 data

(4) (7) EWMA (Exponentially Weighted Moving Average)


A3 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles

A3 0C (7) Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
24

Misfire Cylinder 3 data

(4) (7) EWMA (Exponentially Weighted Moving Average)


A4 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles

A4 0C (7) Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
24

Misfire Cylinder 4 data

(4) (7) EWMA (Exponentially Weighted Moving Average)


A5 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
A5 0C (7) Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
24

Misfire Cylinder 5 data

(4) EWMA (Exponentially Weighted Moving Average)


A6 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
A6 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 6 data

(4) EWMA (Exponentially Weighted Moving Average)


A7 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
A7 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 7 data


EWMA (Exponentially Weighted Moving Average)
A8 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
A8 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Footnotes are explained on the last pages of this document. page 8 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

Misfire Cylinder 8 data


EWMA (Exponentially Weighted Moving Average)
A9 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
A9 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 9 data


EWMA (Exponentially Weighted Moving Average)
AA 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
AA 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 10 data


EWMA (Exponentially Weighted Moving Average)
AB 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
AB 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 11 data


EWMA (Exponentially Weighted Moving Average)
AC A5 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
AC 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Misfire Cylinder 12 data


EWMA (Exponentially Weighted Moving Average)
AD 0B 24 0 to 65535 counts 1 count / bit
misfire counts for the last 10 driving cycles
AD 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit

Footnotes are explained on the last pages of this document. page 9 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

FOOTNOTES

1 For the following 2004 model year vehicles:

Cadillac XLR, SRX with 4.6 liter (VIN A) engine

The following OBDMIDs and TIDs may be defined as shown:

OBDMID $01
TID $10 may be replaced with TID $89

OBDMID $05
TID $10 may be replaced with TID $89

OBDMID $39
TID $39 may be replaced with TID $B0
TID $3A may be replaced with TID $B1

2 For the following 2004 model year vehicles:

Cadillac XLR, SRX with 4.6 liter (VIN A) engine

OBDMID $39 TID $3B test limits and value are invalid.

Footnotes are explained on the last pages of this document. page 10 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

FOOTNOTES

3 For the following 2005 model year vehicles:

Chevrolet Equinox with 3.4 liter (VIN F)


Chevrolet Malibu with 3.5 liter (VIN 8)
Pontiac Grand Am with 3.5 liter (VIN 8)

OBDMID $01 TID $88 test limits and value should be divided by 1000.

4 For the following 2005 model year vehicles:

Chevrolet Equinox with 3.4 liter (VIN F)


Chevrolet Malibu with 3.5 liter (VIN 8)
Pontiac Grand Am with 3.5 liter (VIN 8)

OBDMID $A2 through $A7 TID $0B test value should be multiplied by 10.

5 For the following 2007 model year vehicle:

Buick Lucerne with 3.8L (VIN 2) engine

If the test limit for OBDMID $3D TID $6C reads 8.8 seconds (raw Hex value 58), the test value may be invalid.
If the test value is more than the test limit -and- P0446 is not set, the data is invalid.
If the test value is less than the test limit -and- P0446 is set, the data may be invalid.

Footnotes are explained on the last pages of this document. page 11 of 12 GMLAN rev3
GM mode $06 data definitions for GM vehicles using GMLAN diagnostic data link
Some items have footnotes, defined on the last pages.

OBD Monitor Test Units and Scaling Range Resolution


For Information ONLY. For Information ONLY.
ID ID ID Description
Source information is Source information is
(OBDMID) (TID) (UASID) ISO-15031-5 document ISO-15031-5 document

FOOTNOTES

6 For the following 2006 model year vehicles:

Buick Lucerne with 4.6L (VIN Y) engine


Cadillac DTS with 4.6L (VIN Y -or- 9) engine

OBDMID $31 TID $A9 test limits and test value should be multiplied by 4 (limit result to –32.768 -to- +32.767 kPa).

7 For the following 2007 model year vehicle:

Pontiac Solstice, Saturn Sky, with 2.0L (VIN X) engine.

The OBDMID $A3, $A4, and $A5 are misaligned with the cylinders.
OBDMID $A3 Test IDs contain misfire data for cylinder #3, (not #2).
OBDMID $A4 Test IDs contain misfire data for cylinder #4, (not #3).
OBDMID $A5 Test IDs contain misfire data for cylinder #2, (not #4).

Footnotes are explained on the last pages of this document. page 12 of 12 GMLAN rev3