PowerView Error Messages

Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09

0710170 02-13-07 Section 78

SPN
28 28 29 29 84 91 91 91 91 91 91 94 94 94 94 94 94 94 94 97 97 97 97 97 98 100 100 100 100 100 100 102 105 105 105 105 105 107 107 108 110 110 110 110 110

FMI
3 4 3 4 8 2 3 4 9 11 14 1 3 4 10 13 16 17 18 0 3 4 16 31 1 1 2 3 4 16 18 2 0 2 3 4 16 0 31 12 0 2 3 4 15

Description
% ACCEL POS3 VOLT ABOVE NORM OR SHORT HIGH % ACCEL POS3 VOLT BELOW NORM OR SHORT LOW % ACCEL POS2 VOLT ABOVE NORM OR SHORT HIGH % ACCEL POS2 VOLT BELOW NORM OR SHORT LOW TACHOMETER SIGNAL FAILED, VELOCITY SIGNAL DEFECTIVE SPEED SET POINT1 (ACCELERATOR PEDAL DEFECTIVE) ACCEL PEDAL POS VOLT ABOVE NORM OR SHORT HIGH ACCEL PEDAL POS VOLT BELOW NORMAL OR SHORT LOW ACCEL PEDAL POS A VALID THROTTLE MSG NOT RCVD ERROR HARD SET POINT 1 ACCEL PEDAL POS THROTTLE SIG VOLT OUT OF RANGE FUEL DELIVERY PRESSURE VERY LOW FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE HIGH FUEL RAIL PRESSURE VOLTAGE OUT OF RANGE LOW FUEL DELIVERY PRESSURE DROPPING TOO FAST FUEL DELIVERY PRESSURE OUT OF CALIBRATION FUEL DELIVERY PRESSURE HIGH NO RAIL FUEL PRESSURE FUEL DELIVERY PRESSURE LOW WATER IN FUEL DETECTED WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE HIGH WATER IN FUEL INDICATOR VOLTAGE OUT OF RANGE LOW WATER IN FUEL DETECTED WATER IN FUEL DETECTED OIL LEVEL SWITCH OFF ENGINE OIL PRESSURE LOW OIL PRESSURE SENSOR DEFECTIVE ENGINE OIL PRESS VOLT ABOVE NORM OR SHORT HIGH SOURCE ENGINE OIL PRESS VOLT BELOW NORM OR SHORT LOW SOURCE ENGINE OIL PRESSURE READING INCORRECT ENGINE OIL PRESS LOW CHARGE AIR PRESSURE SENSOR DEFECTIVE INTAKE MAN1 AIR TEMP HIGH CHARGE AIR TEMPERATURE SENSOR DEFECTIVE INTAKE MAN1 TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE INTAKE MAN1 TEMP VOLT BELOW NORM OR SHORT LOW SOURCE INTAKE MAN1 AIR TEMP HIGH AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED AIR FILT DIFF PRESS PLUGGED AIR FILTER DETECTED ATMOSPHERIC PRESSURE ENG COOL TEMP HIGH COOLANT TEMPERATURE SENSOR DEFECTIVE ENG COOL TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE ENG COOL TEMP VOLT BELOW NORM OR SHORT LOW SOURCE ENG COOL TEMP HIGH

Page 1 of 4.

PowerView Error Messages


Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09

SPN
110 111 120 158 158 171 174 174 174 174 174 174 174 177 189 190 190 190 190 190 190 190 201 441 535 535 536 536 563 563 572 611 611 620 620 627 627 629 629 632 632 632 636 636 636 637

FMI
16 1 15 2 17 12 0 2 3 4 15 16 31 15 31 0 2 3 4 5 8 16 2 0 7 13 12 13 2 6 2 3 4 3 4 1 4 13 19 2 5 11 2 8 10 2

Description
ENG COOL TEMP HIGH LOW COOLANT LEVEL RETARDER OIL TEMPERATURE ABOVE NORMAL KEYSWITCH INTERMITTENT KEYSWITCH CIRCUIT PROBLEM INTERNAL TEMPERATURE FUEL TEMP HIGH FUEL TEMPERATURE SENSOR DEFECTIVE FUEL TEMP VOLT ABOVE NORM OR SHORT HIGH SOURCE FUEL TEMP VOLT BELOW NORM OR SHORT LOW SOURCE FUEL TEMP HIGH FUEL TEMP HIGH FUEL TEMP VOLT OUT OF RANGE TRANSMISSION OIL TEMPERATURE ABOVE NORMAL ENG SPEED DERATE CONDITION EXISTS DUE TO FAULT ENGINE OVERSPEED ENG SPD DATA ERRATIC, INTERMITTENT OR INCORRECT ENG SPD VOLT ABOVE NORMAL OR SHORT HIGH ENG SPD VOLT BELOW NORMAL OR SHORT LOW ENG SPD CIRCUIT IS OPEN ENGINE SPEED SENSOR DEFECTIVE ENGINE OVERSPEED SPEED SET POINT 2 (HAND THROTTLE DEFECTIVE) AUXILIARY TEMPERATURE #1 HIGH (MOST SEVERE) CONTROL TRAVEL DIFFERENCE AUTO CALIBRATION BOSCH-EDC-PUMP UNSUCCESSFUL FEEDBACK RACK POSITION REFERENCE FEEDBACK RACK POSITION DIGITAL OUTPUT 3 SUPERVISION (STOP SOLENOID) EXCESS CURRENT DIGITAL OUTPUT 3 (STOP SOLENOID) DIGITAL OUTPUT 6 SUPERVISION INJ WIRING SHORTED TO BATTERY INJ WIRING SHORTED TO GROUND SENSOR VOLT1 (+5VDC)ABOVE NORMAL OR SHORT HIGH SENSOR VOLT1 (+5VDC)BELOW NORMAL OR SHORT LOW POWER SUPPLY LOW VOLT TO INJECTORS POWER SUPPLY INTERRUPTION REPROGRAM CONTROLLER ECU PROBLEM ECU NOT RECEIVING MSG FROM PUMP FUEL SHUTOFF VALVE ERR DETECTED FUEL SHUTOFF VALVE NON-FUNCTIONAL FUEL SHUTOFF VALVE SOLENOID CKT OPEN OR SHORTED ENG POS SENSOR TIMING SIGNAL ERROR ENG POS SENSOR TIMING SIGNAL ERROR ENG POS SENSOR TIMING SIGNAL ERROR TIMING (CRANK) SENSOR TIMING SIGNAL ERROR Page 2 of 4.

PowerView Error Messages


Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09

SPN
637 637 637 639 651 651 651 652 652 652 653 653 653 654 654 654 655 655 655 656 656 656 676 676 702 729 729 743 743 743 752 752 765 765 766 833 833 833 834 834 834 834 834 898 970 970

FMI
7 8 10 13 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7 5 6 7 3 5 14 3 5 9 12 14 2 12 2 12 2 2 3 4 2 3 5 6 7 2 2 11

Description
TIMING (CRANK) SENSOR TIMING SIGNAL ERROR TIMING (CRANK) SENSOR TIMING SIGNAL ERROR TIMING (CRANK) SENSOR TIMING SIGNAL ERROR CAN BUS FAILURE INJ CYLINDER1 CURRENT LESS THAN EXPECTED INJ CYLINDER1 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER1 FUEL FLOW LOWER THAN EXPECTED INJ CYLINDER2 CURRENT LESS THAN EXPECTED INJ CYLINDER2 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER2 FUEL FLOW LOWER THAN EXPECTED INJ CYLINDER3 CURRENT LESS THAN EXPECTED INJ CYLINDER3 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER3 FUEL FLOW LOWER THAN EXPECTED INJ CYLINDER4 CURRENT LESS THAN EXPECTED INJ CYLINDER4 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER4 FUEL FLOW LOWER THAN EXPECTED INJ CYLINDER5 CURRENT LESS THAN EXPECTED INJ CYLINDER5 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER5 FUEL FLOW LOWER THAN EXPECTED INJ CYLINDER6 CURRENT LESS THAN EXPECTED INJ CYLINDER6 CURRENT INCREASES TOO RAPIDLY INJ CYLINDER6 FUEL FLOW LOWER THAN EXPECTED GLOW PLUG RELAY STUCK ON GLOW PLUG RELAY WILL NOT TURN ON SPEED (THRUST MODE) WARNING INLET AIR HEATER DRIVER1 STUCK ON INLET AIR HEATER DRIVER1 WILL NOT TURN ON CAN COMMUNICATION SAE J1939, RECEIVE MESSAGES MISSING CAN CONTROLLER, BUS OFF LINE BREAK, SHORT OR HEAVY BUS LOAD (CAN BUS PASSIVE) STACK-OVERFLOW CYCLIC FLASH TEST PARAMETER ERROR (EEPROM CHECKSUM INCORRECT) PARAMETER PROGRAMMING (EEPROM WRITING ERROR) INTERNAL ERROR RACK POSITION SENSOR ERROR RACK POSITION SENSOR VOLT ABOVE NORMAL RACK POSITION SENSOR VOLT BELOW NORMAL RACK ACTUATOR ERROR BLEED AIR IN FUEL SYSTEM RACK ACTUATOR CKT VOLT ABOVE NORMAL RACK ACTUATOR CKT OPEN RACK ACTUATOR CKT GROUNDED RACK ACTUATOR POSITION ERROR ERROR CAN SET POINT 1 EXT AUX ENG SHUTDOWN SWITCH INTERMITTENT EXT ENG PROTECTION SHUTDOWN ACTIVE Page 3 of 4.

PowerView Error Messages


Diagnostic Trouble Codes Text Translations provided by: PowerView Model PV101 software version Murphy 1.00.06 PowerView Model PV100 software version Murphy 2.09

SPN
970 971 1041 1041 1076 1076 1076 1076 1076 1076 1076 1076 1076 1077 1077 1077 1077 1077 1078 1078 1078 1079 1079 1080 1080 1109 1110 1347 1347 1347 1348 1348 1387 1485 1569 2000 2000 2003

FMI
31 31 2 3 0 1 2 3 5 6 7 10 13 7 11 12 19 31 7 11 31 3 4 3 4 31 31 5 7 10 5 10 1 2 31 6 13 31

Description
EXT AUX ENG SHUTDOWN SWITCH ACTIVE ENG DERATE SWITCH ACTIVATED START SIGNAL MISSING START SIGNAL ALWAYS ACTIVE FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP CONT VALVE ERROR FUEL INJ PUMP ERROR FUEL INJ PUMP CONT VP44 INPUT VOLT OUT OF RANGE FUEL INJ PUMP CONT VP44 SELF TEST ERROR FUEL INJ PUMP CONT VP44 DETECTED CAN BUS FAILURE FUEL INJ PUMP CONT POWER DERATED FUEL INJ PUMP SPD/POS SENSOR ERROR FUEL INJ PUMP SPD/POS SENSOR ERROR FUEL INJ PUMP SPD/POS VP44 UNABLE TO ACHIEVE TIMING SENSOR VOLT1 (+5VDC)ABOVE NORM OR SHORT HIGH SENSOR VOLT1 (+5VDC)BELOW NORM OR SHORT LOW SENSOR VOLT2 (+5VDC)ABOVE NORM OR SHORT HIGH SENSOR VOLT2 (+5VDC)BELOW NORM OR SHORT LOW ENG PROT SYSTEM APPROACHING SHUTDOWN ENG PROT SYSTEM SHUT ENG DOWN FUEL PUMP ASSY 1 CKT OPEN, SHORTED GROUND OR OVLOAD FUEL PUMP ASSY 1 RAIL PRESSURE CONT MISMATCH FUEL PUMP ASSY 1 LOW FUEL FLOW FUEL PUMP ASSY 2 CKT OPEN, SHORTED GROUND OR OVLOAD FUEL PUMP ASSY 2 LOW FUEL FLOW AUXILIARY PRESSURE #1 LOW (MOST SEVERE) ECU MAIN RELAY PUMP POWER RELAY FAULT ENG PROT TORQ FUEL DERATE LIMIT CONDITION EXIST FUEL INJECTION PUMP CONT VALVE ERROR SECURITY VIOLATION PROPER CONT NOT INSTALLED GENERAL TRANSMISSION FAULT UNKNOWN Page 4 of 4.

You might also like