Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Fullcatalog

Download as pdf or txt
Download as pdf or txt
You are on page 1of 150

ENGINEERING CATALOG

June, 2010

POWER BLOCKS

Whats New:
Class J Enclosed Fuse Holders Motor Terminal Blocks

FUSE HOLDERS

Listed Power Dist Blocks (135) Listed Enclosed Power Dist Blocks Redesigned 1000V Studded Fuse Holder 7/16 Sectional Terminal Blocks

ENCLOSED POWER BLOCKS

CUSTOM PRODUCTS

TERMINAL BLOCKS

Marathon is...
Quality Shortest Delivery Times Customer Satisfaction

MADE IN USA

Table of Contents
1000 Volt CE Ratings General Information Flexible Stranded Wire Fuse Holders
2 3-4 5-6

Double Row Terminal Blocks (cont.)


603 GP Series 604 GP Series 605 GP Series 621 RZ Series 670A RZ Series 671 RZ Series 672 RZ Series

General Information 7-8 Class H & K Fuse Panels - 250 Volt 9 - 10 Class H & K Fuse Holders - 250/600 Volt 11 Class R Fuse Holders - 250/600 Volt 12 Class H, K & R Fuse Holder Dimensions 13 - 15 Class T Fuse Holders - 300/600 Volt 16 Class T Fuse Holder Dimensions 17 - 18 Class J Fuse Holders - 600 Volt 19 Class J Fuse Holder Dimensions 20 - 21 Class J Enclosed Fuse Holders - 600 Volt 22 M Fuse Holders - 600 Volt 23 Midget Enclosed Fuse Holders - 600/1000 Volt 24 Midget Fuse Holders (Sectional) - 600 Volt 25 CC Fuse Holders - 600 Volt 26 CC Enclosed Fuse Holders - 600 Volt 27 Class G Fuse Holders 28 Semi Conductor Fuse Holder (Box) - 600 Volt 29 Semi Conductor Fuse Holder (Stud) - 1,000 Volt 30 Fuse Holders with Box Distribution (BD) Connectors 31 STSF Forklift/Semi Conductor Fuse Holder 32 Fuse Holder Covers 33 - 34 DIN Rail Adapters 35 Short Circuit Current Ratings 36 Feeder Spacing/Adapter Plates 36 UL Listed Power Distribution Blocks 37 - 39 UL Listed Enclosed Power Dist Blocks 40 - 41 Enclosed Power Distribution Blocks 42

Single Row Terminal Blocks


General Information 411 Series 599 Series (799 Riveted) 699 Series (899 Riveted) 812 Series (912 Riveted) 1690 Series 2590 Series 2690 Series

87 88 89 90 91 92 93 94 95 96 97 98 99 - 100 101 102 - 103 104 105 106 107 108 109 110 111 112 113 114 115

Terminal Block Accessories

Power Terminal Blocks

Sectional Terminal Blocks


General Information 3/8 Sectional Blocks 7/16 Sectional Blocks 1/2 Sectional Blocks 11/16 Sectional Fuse Holder

Kliptite/Quick Connect (Single Row) Kliptite/Quick Connect (Double Row) Solder Terminal Lugs (ST, 3/4 ST, Y, YSY, Z) J/JS/RJ/RJS Jumpers, Wire Clamp, Straddle Plate Fanning Strips Stud & Turret Terminal Blocks Top Mounted Covers/Marking Strips (Double Row) Sub Mounted Marking Strips (Double Row) Marking and Insulator Strips Marking Strip Dimensions (Single Row) Marking Strip Dimensions (Double Row) Terminal Block Printing

Studded Power Feed Thru TBs

General Information Power Distribution Blocks Power Splicer Blocks Power Stud Blocks Miscellaneous Power Splicer Blocks Power Splicer/Stud Blocks Power Stud to Distribution Blocks Power Terminal Block Dimensions Power Block Covers Grounding Lugs - GL

44 48 50 -

55 -

43 47 49 51 52 53 54 57 58 59

DIN Rail Terminal Blocks


General Information MIK3 MIK5 MIK10 MIK16 MIK25 DIN Rail Disconnect - MIKTS4 Fuse Terminal Block - MIKSI5 MIKE4 MIKE10 MIKE16 DIN Accessories

116 117 - 118 119 120 121 122 123 124 125 126 127 128 129 129 129 129 130 131 132 133 134 135 136 137 138 139 140 141 142 - 143 144 - 145 146 148

Single Stud Connection Block Motor Terminal Blocks (IEC Style) Heavy Duty Terminal Blocks
General Information 1100 Series 1103P & 1200 Series 0987 RZ Series 985 GP Series 1500 Series 1600 Series 1700 Series

General Information - ST722 Series/Covers ST722B Series (back mount) ST722S Series (slide-in mount) ST722E Series (end mount) ST715S1902 and cover ST723B38 Series (back mount)

60 61 62 63 64 65 66 67 - 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86

Military and Navy Class TBs

Double Row Terminal Blocks


General Information 100/670A GP Series 200/671 GP Series 300/672 GP Series 400 Series 410 GP Series 600 GP Series 600A GP Series (800A Riveted) 601 GP Series (801 Riveted) 602 GP Series (802 Riveted)

General Information - Military Class 37TB-B & 40TB-B Series 37TB F & 38TB F Series 39TB F & 40 TB F Series 41TB F & 42TB F Series LD, LS Options Military Block Marking Styles General Information - Navy Class 3TB, 4TB, 5TB, 6TB Series 7TB, 8TB, 9TB, 10TB, 11TB Series 15TB, 16TB, 17TB, 25TB, 26TB Series

Index Terms and Conditions Warnings and Cautions Custom Products

Datasheets available at marathonsp.com

1,000 Volt CE Ratings


Voltage Ratings per IEC 60947-1 and IEC 60947-7-1
ENCLOSED POWER BLOCKS
Catalog Description EPBAD21 EPBAD24 EPBXD42 EPBXD45 Voltage Rating (Ui) - AC/DC 1,000 1,000 1,000 1,000 Current Range AMP up up up up to to to to 115 115 200 200 Special Features/Notes Din/Panel Din/Panel Din/Panel Din/Panel Mount Mount Mount Mount LISTED ENCLOSED POWER BLOCKS

RECOGNIZED ENCLOSED POWER BLOCKS EPBXD74 EPBXP74 EPBXD71 EPBXP71 800 1,000 800 1,000 up up up up to to to to 335 335 510 510 Din Rail Mount Panel Mount Din Rail Mount Panel Mount

NEMA POWER BLOCKS


Catalog Description 132XXXX 133XXXX 140XXXX 141XXXX 142XXXX 143XXXX 144XXXX 145XXXX Voltage Rating (Ui) - AC/DC 1,000 1,000 1,000 800 1,000 1,000 1,000 1,000 Current Range AMP up up up up up up up up to to to to to to to to 175 510 310 115 175 350 420 760 Special Features/Notes

HEAVY DUTY TERMINAL BLOCKS


Catalog Description 1100 Series 1200 Series 0987 Series 985 Series 1500 Series 1600 Series 1700 Series Voltage Rating (Ui) - AC/DC 630 800 1,000 630 1,000 1,000 1,000 Current Range AMP up to 65 up to 70 up to 50 up to 85 up to 75 up to 75 up to 75 Special Features/Notes

>30A ring lug >30A ring lug >30A ring lug

Voltage Ratings per IEC 60269


FUSE HOLDERS
Catalog Description Voltage Rating (Ui) - AC/DC Current Range AMP up to 30 up to 30 up to 30 up to 101 ~ 101 ~ 401 ~ 100 400 400 600 400 800 1,200 Special Features/Notes Marathon certifies 1000 Volt Rating (FSM Series is UL rated for UL 1000V AC/DC) CLASS M/ENCLOSED FUSE HOLDERS 6SM30AXB 1,000 6SM30AXIB 1,000 6M30AXX 800 SEMI-CONDUCTOR FUSE HOLDERS 1MS101 1MS102 1MS103 1MS104 FSM25E FSM37E FSM50E 1,000 1,000 1,000 1,000 1,000 1,000 1,000

Notes (applies to two groups) 1. Material Group - IIIa except 6M30AX series in Fuse Holders with material group - I 2. Pollution Group - 3

1,000 Volt

Datasheets available at marathonsp.com

General Information
Marathon Special Products, a Regal Beloit Company, has served the electrical/electronic component industry for over 70 years. Our facility in Bowling Green, Ohio contains all manufacturing and warehousing operations including an extensive electrical test lab. We offer a broad range of fuse holders and terminal blocks, including Kulka terminal blocks. In addition, we have the expertise to design and manufacture non-standard products for specific customer applications. On February 1, 1994, Marathon Special Products was registered to ISO standards. We are currently registered to ISO 9001:2000 quality standards. Marathon Special Products also offers a line of DIN sectional terminal blocks.

Agency Approvals:

The majority of products manufactured by Marathon Special Products are Underwriters Laboratories and Canadian Standards Association approved. The approval status of products can be found throughout the catalog. Below are the different approval forms and brief descriptions. Listed products by Underwriters Laboratories have been evaluated to U.S. safety requirements. These products are qualified for use in equipment without end-use agency approval when applied within the products rated performance. Listed products by Underwriters Laboratories have been evaluated to both U.S. and Canadian safety requirements. These products are qualified for use in equipment without end-use agency approval when applied within the products rated performance. Recognized products by Underwriters Laboratories have been evaluated to U.S. safety requirements. These products are components of a larger product or system and have guidelines addressing the suitability when used in an end product. Recognized products by Underwriters Laboratories have been evaluated to U.S. and Canadian safety requirements. These products are components of a larger product or system and have guidelines addressing the suitability when used in an end product. Certified by Canadian Standards Association, suitable for use in other equipment where Canadian Standards Association determines the suitability of the combination. Compliance with European Union Low Voltage Directive.

Environmental Compliance: Tightening Torque:

All products offered by Marathon Special Products are RoHS compliant and do not require REACH notification.

Recommended tightening torque is listed for all products, either on the carton label or the product label. All torque recommendations are based on UL 486. In some cases, because of various connector designs, our recommended torque is different from the torque tables shown in UL 486. However, these products passed the heating cycling and static heating tests as specified in UL 486.

Wire Ampacity:

The ampacity of a wire is its current carrying capacity with reference to the cross sectional area of the conductor(s), the temperature rating of the insulation and ambient temperature. Marathon specified wire ranges are based on UL approved tests using 75oC wire. Wires with temperature ratings other than 75oC are approved while observing NEC Article 310 wire tables for allowable ampacities of insulated conductors. Marathon voltage and amperage ratings remain constant and are independent of the temperature rating of the wire used in application. Wire gauges and type must remain within the Marathon specified ranges to be UL approved. However, UL approval for higher currents may be obtained in some end-use applications.

Datasheets available at marathonsp.com

General Information
Wire Chart:
Wire diameter is based on UL Class B and C stranded wire (also known as code wire, building wire, or rigid stranded wire).

SIZE DIAMETER AMPS

#14 .073 15

#12 .092 20

#10 .115 30

#8 .146 50

#6 .184 65

#4 .235 85

#3 .281 100

#2 .295 115

#1 .335 130

1/0 .380 150

2/0 .420 175

3/0 .475 200

4/0 .530 230

SIZE DIAMETER AMPS

250kcmil .580 255

300kcmil .635 285

350kcmil .690 310

400kcmil .730 335

500kcmil .820 380

600kcmil .893 420

750kcmil .998 475

Tolerances for Catalog Dimensions: Length Dimensions


1.0 - 5.0 5.1 - 10.0 10.1 - 15.0

Tolerance
.030 .050 .060

All Other Dimensions


X.X X.XX X.XXX

Tolerance
.030 .020 .010

Note: Catalog Dimensions are for guidance only and are not to be construed as inspection standards. This catalog is intended to present product data that will help the end user with design application. Since changes to products occur, it is recommended that the end user request samples for evaluation. Marathon Special Products reserves the right to change or update without notice. Please visit www.marathonsp.com for the most up-to-date product information.

Torque Conversions: Lb-in


2 5 6 8 10 15 18 20

N-m
0.2 0.6 0.7 0.9 1.1 1.7 2.0 2.3

Lb-in
25 30 35 40 45 50 61 80

N-m
2.8 3.4 4.0 4.5 5.1 5.6 6.9 9.0

Lb-in
100 120 150 192 275 375 422 500

N-m
11.3 13.6 16.9 21.7 31.1 42.4 47.7 56.5

Datasheets available at marathonsp.com

Wire Connectors Investigated for Flexible Stranded Wire


Flexible Stranded Wire

Specifications:
Screw-type mechanical pressure wire connectors investigated to UL 486A-B for flexible stranded wire UL 508A (Industrial Control Panels), Section 29.3.11

Affected Standards:
UL 486A-486B (Wire Connectors Standard) UL 508A (Industrial Control Panels Standard) UL 1059 (Terminal Block Standard) NEC (National Electric Code) 110.3 (A)7 and (B) NEC 690 (in 2008)

To be UL and NEC compliant while using flexible stranded wire, it was necessary to use crimp-type ring lugs investigated for flexible stranded wire. By using Marathons UL 486A-B investigated screw-type pressure connectors in place of crimp lugs, you can save up to 66% of termination costs in material and labor. Marathons wire approvals, in addition to Classes B and C, now include stranding Classes G, H, I and K. The photo shows two distinctly different stranding classes, both 250 kcmil. The wire on the left, Class B, has 37 strands. The wire on the right, Class K, has approximately 2499 strands. A table providing information on wire sizes, Classes and strand count can be found on the next page.

29.3.11 Flexible conductors, including welding cable and machine tool wire identified as Flexing or Class K, shall be retained by terminals that have been evaluated to the Standard for Wire Connectors, UL 486A-486B for the size and type of conductors involved. Added 29.3.11 effective March 1, 2007

For specific rating information view our online datasheets at www.marathonsp.com

Datasheets available at marathonsp.com

Copper Stranded Wire Classes


AWG/kcmil

Flexible Stranded Wire

Rigid Stranded CSA Compact Wire Gauge


#20 AWG #18 #16 #14 #12 #10 #8 #6 #4 #2 #1 1/0 2/0 3/0 4/0 250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 750 kcmil 1,000 kcmil

Flexible Stranded Class C Class G Class H Class I (DLO) Class K Wire Gauge
#20 AWG #18 #16 #14 #12 #10 #8 #6 #4 #2 #1 1/0 2/0 3/0 4/0 250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 750 kcmil 1,000 kcmil

Class B

Number of Number of Number of Number of Number of Number of Number of Strands Strands Strands Strands* Strands* Strands* Strands*
7 7 7 7 7 7 7 7 7 7 19 19 19 19 19 37 37 37 37 37 37 61 61 19 19 19 19 19 19 19 19 19 19 37 37 37 37 37 61 61 61 61 61 61 61 61 10 16 26 41 65 104 168 266 420 665 836 1064 1323 1666 2107 2499 2989 3458 3990 5054 6065 7581 10101

7 7 7 7 19 19 19 19 19 37 37 37 37 37 37 37 37

49 49 49 49 133 133 133 133 133 259 259 259 259 259 427 427 427

133 133 133 133 259 259 259 259 259 427 427 427 427 427 427 427 427

19 19 27 41 63 105 161 210 266 342 418 532 637 735 882 980 1225 1470 1850 2527

mm2
Rigid Class 2 Flexible Class 5 Wire Gauge
.50 mm2 0.75 1.50 2.50 4 6 10 16 25 35 50 70 95 120 150 185 240 300

*Specific quantity of strands for Classes G, H, I (DLO), K and 5 vary by manufacturer.

Wire Number Number of Gauge of Strands Strands*


.50 mm2 0.75 1.50 2.50 4 6 10 16 25 35 50 70 95 120 150 185 240 300 7 7 7 7 7 7 7 7 7 7 19 19 19 37 37 37 61 61 16 24 30 50 56 84 80 128 200 280 400 356 485 614 765 765 1225 1530

For additional information on copper stranded wire classes and approvals on Marathon products go to www.marathonsp.com

Datasheets available at marathonsp.com

Fuse Holders

General Information:
Marathon has been manufacturing quality fuse holders incorporated in the design of every Marathon fuse holder. for over 40 years. Quality is

Fuse Holders

The product line includes a broad range of holders to accommodate the following fuses: Class H, K, R, T, J, CC, G, CD, M (Miscellaneous/10x38) and Semi-Conductor holders. The majority of these fuse holders are available from 250 to 1000 volts at current ratings from 30 through 600 Amperes. The Class R, T, J, CD, CC and Semi-Conductor fuse holders have passed 200,000 ampere short circuit withstand testing in accordance with the fuse holder standard UL 512 and complies to new harmonized standard UL 4248. Class R and CC fuse holders have a rejection feature, which prevents the insertion of a fuse with lower interrupting rating. Class T and J fuse holders prevent the use of fuses with lower interrupting rating because of their unique size.

Fuse Clips:
Marathons 30 and 60 Amp fuse holders are equipped with the patented Cool-Clip design. The heat generated in a fuse clip can actually reduce the life of the fuse, the clip and the conductor, as well as the protection power of the fusing device. Reinforcing members are available for most Marathon fuse holders and are recommended for use where an improved performance is desired or more severe conditions exist. They are recommended for electric heat or where high ambient temperatures are present. To comply with Automotive Industry Standard ET-2 use the following options: Class H Fuse Holder with Reinforcing Member 30 Amp use SP Connectors or Copper Box Connectors 60 Amp use Copper Box Connectors

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

Fuse Holders
Wire Connectors:
Marathon fuse holders are available with five types of wire connectors.

Fuse Holders

S SQ SP

An economical connector for use with a wire, or either a ring or spade type terminal. Screw is #10-32 steel. Same as screw connector with additional quick connect options. A positive pressure connector eliminating the need for a wire terminal. Ideal for use where there is a vibration problem. Sems pressure screw is #10-32 steel. Same as Sems connector with additional quick connect options. Suitable for use with stranded or solid wire. Connector is aluminum tin plated. Copper Box Connectors are available on 30 and 60 amp fuse holders. Add CU after the catalog number.

Screw Connector

Screw Connector w/Quick Connects Sems Pressure Connector

SPQ B

Sems Pressure Connector w/Quick Connects Box Connector

Wire Ranges:
All wire ranges shown in the fuse holder section are the ranges of the wire that the connector will accept or that is recommended for the fuse holder assembly.

Ordering Code:
Reinforcing Member Amp Rating Connector Style

30A

CU

Designates Class H Fuse Holder F = 250 Volt Rating 6F = 600 Volt Rating

# of Poles

Copper Box Connector (Optional)

Applications:
Marathon fuse holders can be used in various applications, including control panels, lighting and heating circuits, motor circuits, circuit breaker protection, switchgear equipment, appliances, electric heat, air conditioning and refrigeration equipment, elevator systems, transformer protection, and solar applications.
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Class H & K Fuse Panels


30 and 60 Amp - 250 Volt
Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Patented Cool-Clip Design Clip, Copper Alloy, Tin Plated Reinforcing Member Available Bus Bars are Available with 2/0 - #14 AWG or 250 kcmil - #6 Wire Ranges Consult Customer Service for Special Requirements UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455 RoHS Compliant

Fuse Holders

RH40Q2L

Ordering Code:
Reinforcing Member
RH42C2F

Class H Fuse Distribution Panels Number of Poles 2, 3, 4, 5 or 6

H
Amp Rating of Poles
0 1 2 3 = = = =

60 Amps All Poles 30 Amps All Poles 30,60 Any Combination 30, 60, 60 Any Combination

Entry of Bus Bar (Only if Bussed) F=Front L=Lateral

Load Termination
S = Wire Binding Screw B = Box Connector #2 - 14 CU #6 - 14 CU P = SEMS Pressure Screw Q = .250 Male Quick Connect C = Combination of the Above (consult Customer Service)
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Line Terminations
Code Same As Load Termination. Omit if line Termination is Same as Load (S, B, P, Q or C). OR

Bussing Arrangements
1 2 3 4 = = = = Special Bussing (consult Cust. Service) Poles Bussed by Pairs Poles Bussed by Threes Poles Bussed by Fours

Datasheets available at marathonsp.com

Class H & K Fuse Panels


30 and 60 Amp - 250 Volt
7.50 [190.5] 6.25 [158.8]

(cont.)

Fuse Holders

5.00 [127.0] 3.75 [95.3] 2.50 [63.5] 1.75 [44.5] 0.68 [17.3]

2.13 [54.0]

0.13 [3.2]

4.80 [121.9]

0.63 [15.9]

1.25 [31.8] .22[5.6] X .41[10.4] HOLE.50 .50[12.7] X .68[17.3] C'BORE X .55[14.0] DEEP

1.34 [34.0]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Poles No. 2 3 4

Dimensions (in) L 2.50 3.75 5.00

(mm) 63.5 95.25 127.0

Poles No. 5 6

Dimensions (in) L 6.25 7.50

(mm) 158.8 190.5

Dimensions (in) (mm)

Fuse Distribution Panel Options


Circle/indicate one item per pole and number of poles. The items to be indicated are within the rectangles. Bussing is only available on line side. If bussing, indicate lug size 2/0 or 250 kcmil (F = Front entry, L = Lateral entry) Consult Customer Service for other modifications.
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.
F/L BUSSING F/L 2/0 OR 250 MCM F/L

F/L SCREW/QC SP/QC BOX 2 QC 4 QC SCREW/QC SP/QC BOX 2 QC 4 QC

F/L SCREW/QC SP/QC BOX 2 QC 4 QC SCREW/QC SP/QC BOX 2 QC 4 QC

F/L SCREW/QC SP/QC BOX 2 QC 4 QC SCREW/QC SP/QC BOX 2 QC 4 QC

LINE SIDE

POLE AMPS

30A 60A

30A 60A

30A 60A

30A 60A

30A 60A

30A 60A

LOAD SIDE

SCREW/QC SP/QC BOX 2 QC 4 QC

SCREW/QC SP/QC BOX 2 QC 4 QC

SCREW/QC SP/QC BOX 2 QC 4 QC

SCREW/QC SP/QC BOX 2 QC 4 QC

SCREW/QC SP/QC BOX 2 QC 4 QC

SCREW/QC SP/QC BOX 2 QC 4 QC

REINFORCED/UNREINFORCED

10

Datasheets available at marathonsp.com

Class H & K Fuse Holders - 250/600 Volt


Specifications:
RoHS Compliant 30 & 60 Amp
Clip, Copper Alloy, Tin Plated Patented Cool-Clip Design For box connectors, internal hex screw option available

Approved for 10,000 Amp Withstand Rating and Short Circuit Withstand Rating UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455

Fuse Holders

200 Amp
Clip, One Piece Aluminum, Tin Plated

100 Amp
Clip, Copper Alloy, Tin Plated

400 & 600 Amp


Clip, Copper Alloy, Tin Plated

250 Volts - Catalog#:


Standard F30AXS F30AXSP F30AXB F60AXSQ* F60AXB RF100AXB F200AXBE RF400AXB F600AXB N/A SAME 1/3 Reinforced Poles (X) Amps Base Materials RF30AXS RF30AXSP RF30AXB RF60AXSQ* RF60AXB 1/2/3 60 30 Thermoplastic Wire Range

Replace X with # of poles


Fuse Size 9/16 DIA BY 2 Fuses A2Y CRN 13/16 DIA BY 3 NLN NON NRN OT OTN RLN RF
F30A3SP

#10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #10-#22 AWG CU #2-#14 AWG CU #2-#12 AWG AL Phenolic Polyester 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 350 kcmil 1/0 AWG CU AL (2) 500 kcmil 1/0 AWG CU AL

100 200 400 600

1 DIA BY 5 7/8 1 1/2 DIA BY 7 1/8 2 13/32 DIA BY 8 5/8 2 29/32 DIA BY 10 3/8

Phenolic

*UL Recognized File No. IZLT2.E35113

F200A3BE

600 Volts - Catalog#:


Standard 6F30AXS 6F30AXSP 6F30AXB 6F60AXB R6F100AXB 6F200AXBE R6F400AXB 6F600AXB N/A SAME 1/3 Reinforced Poles (X) Amps Base Materials R6F30AXS R6F30AXSP R6F30AXB R6F60AXB 1/2/3 60 100 200 400 Phenolic 600 Polyester 30 Phenolic Wire Range

Replace X with # of poles


Fuse Size 13/16 DIA BY 5 1 1/16 DIA BY 5 1/2 1 11/32 DIA BY 7 7/8 1 3/4 DIA BY 9 5/8 2 29/32 DIA BY 11 5/8 3 7/16 DIA BY 13 3/8 Fuses A6Y CRS NLS NOS NRS OTS RES RFS RLS
R6F100A3B 6F30A3B

#10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #2-#14 AWG CU #2-#12 AWG AL 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 350 kcmil 1/0 AWG CU AL (2) 500 kcmil 1/0 AWG CU AL

Contact Customer Service for Stud Options See pages 13-15 for dimensional information
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

See pages 33-34 for available covers See page 35 for DIN Rail Adapter

Datasheets available at marathonsp.com

11

Class R Fuse Holders - 250/600 Volt


Specifications:
RoHS Compliant 30 & 60 Amp
Clip, Copper Alloy, Tin Plated, with Patented Reject Member Patented Cool-Clip Design For box connectors, internal hex screw option available

Fuse Holders

Tested and Approved for 200,000 Amp Withstand Rating and Short Circuit Withstand Rating UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455

200 Amp
Clip, One Piece Aluminum, Tin Plated, with Reject Pin

100 Amp
Clip, Copper Alloy, Tin Plated with Reject Pin

400 & 600 Amp


Clip, Copper Alloy, Tin Plated, with Reject Pin

250 Volts - Catalog #:


Standard R30AXS R30AXSP R30AXB R60AXSQ* R60AXB R100AXB R200AXBE R400AXB R600AXB N/A 1/3 SAME 1/2/3 60 30 Thermoplastic Reinforced Poles (X) Amps Base Materials Wire Range #10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #10-#22 AWG CU #2-#14 AWG CU #2-#12 AWG AL Phenolic Polyester 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 350 kcmil 1/0 AWG CU AL (2) 500 kcmil 1/0 AWG CU AL

Replace X with # of poles


Fuse Size 9/16 DIA BY 2 Fuses A2D-R A2K-R DLN-R 13/16 DIA BY 3 FLNR FRN-R 1 DIA BY 5 7/8 1 1/2 DIA BY 7 1/8 2 13/32 DIA BY 8 5/8 2 29/32 DIA BY 10 3/8 KLNR KTS-R LLNRK LPN-RK TLN TR-R
R200A3BE R30A3S

100 200 400 600

Phenolic

*CSA Certified Only

600 Volts - Catalog #:


Standard 6R30AXS 6R30AXSP 6R30AXB 6R60AXB 6R100AXB 6R200AXBE 6R400AXB 6R600AXB N/A 1/3 SAME 1/2/3 60 100 200 400 Phenolic 600 Polyester 30 Phenolic Reinforced Poles (X) Amps Base Materials Wire Range #10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #2-#14 AWG CU #2-#12 AWG AL 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 350 kcmil 1/0 AWG CU AL (2) 500 kcmil 1/0 AWG CU AL

Replace X with # of poles


Fuse Size 13/16 DIA BY 5 1 1/16 DIA BY 5 1/2 1 11/32 DIA BY 7 7/8 1 3/4 DIA BY 9 5/8 2 29/32 DIA BY 11 5/8 3 7/16 DIA BY 13 3/8 Fuses A6D-R A6K-R DLS-R FLSR FLSR_ID FRS-R IDSR KLSR KTS-R LLSRK LLSRK_ID LPS-RK TRS-R
6R200A3BE 6R30A3B

Contact Customer Service for Stud Options See pages 13-15 for dimensional information
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

See pages 33-34 for available covers See page 35 for DIN Rail Adapter

12

Datasheets available at marathonsp.com

Class H/K/R Fuse Holder Dimensions


Figure F30A RF30A R30A F60A RF60A R60A RF100A R100A 1 2 3 1 2 3 1 2 3 POLE POLE POLE POLE POLE POLE POLE POLE POLE A B C D E F G H I J K L SEE FIGURE #1 1.48 2.86 4.23 1.93 3.49 5.05

FIG 2

4.83

2.01

1.24

1.8

.50

.49

1.33

N/A

N/A

.218 DIA THRU .40 DIA X .63 CBORE .28 DIA THRU .53 DIA X .59 CBORE

Fuse Holders

.11

FIG 2

6.12

2.44

2.37

1.87

.62

.61

1.56

N/A

N/A

.36

mm = dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

FIGURE 1:
.22[5.6] THRU HOLE 4 PLACES .22[5.6] THRU HOLE 2 PLACES

1.25 [31.51]
250 V 250 V 30 A 30 A 250 V 30 A

1.50 [38.1] 3.00 [76.2] 3.00 [76.2]

.50 [13.17] .75 [19.76] 1.12 [26.95] .19 [4.94] .33 [8.4] 1.25 [31.75] 1.91 [48.51] .22 [5.71] 2.50 [63.5] 2.95 [74.93] 1.38 [34.9] .13 [3.2]

1 Pole

2 Pole

3 Pole

FIGURE 2:
K

F G H B B B C L

1 Pole

2 Pole

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

13

Class H/K/R Fuse Holder Dimensions


Figure 6F30A R6F30A 6R30A 1 POLE 2 POLE 3 POLE 1 POLE 2 POLE 3 POLE 1 POLE 2 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE FIG 3 A 6.25 B 1.63 2.94 4.25 1.95 3.51 5.08 2.10 3.91 5.73 3.00 9.00 3.00 9.00 C 1.69 D 3.13 E 1.56 F .31 N/A N/A N/A G .62 H .51 .38 .25 .66 I N/A 1.56 3.13 N/A 1.56 3.12 N/A 1.81 3.62 N/A N/A J .34 N/A N/A N/A K .28 DIA THRU .50 DIA X .44 CBORE .28 DIA THRU .50 DIA X .50 CBORE .28 DIA THRU .59 DIA X .64 CBORE .28 DIA THRU .63 DIA X .38 CBORE .33 DIA THRU .73 DIA X .44 CBORE L .25

Fuse Holders

6F60A R6F60A 6R60A R6F100A 6R100A F200A R200A 6F200A 6R200A

FIG 3

6.75

2.12

3.12

1.81

.62

.33

FIG 3 FIG 4 FIG 4

8.12 7.13 9.63

2.60 3.01 3.01

4.26 3.00 3.00

1.94 2.06 3.31

N/A 2.00 2.00

.87 .50 .5

.61 8.00 8.00

N/A N/A N/A

.23 .26 .26

mm = dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


.20[5.1] THRU (600V 30A ONLY)

FIGURE 3:

D F

H I

G I L B C

1 Pole
FIGURE 4:

2 Pole

3 Pole

5/16 HEX
M
PAT. NO. 4500162 98168

K
M
PAT. NO. 4500162 98168

M
PAT. NO. 4500162

98168

M
PAT. NO. 4500162

98168

250MCM-6 CU7AL

250MCM-6 CU7AL

250MCM-6 CU7AL

250MCM-6 CU7AL

A D

M
PAT. NO. 4500162

98168

M
PAT. NO. 4500162

98168

M
PAT. NO. 4500162

98168

M
PAT. NO. 4500162

98168

250MCM-6 CU7AL

250MCM-6 CU7AL

250MCM-6 CU7AL

250MCM-6 CU7AL

H L

1 Pole

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

14

Datasheets available at marathonsp.com

Class H/K/R Fuse Holder Dimensions


Figure RF400A R400A F600A R600A R6F400A 6R400A 6F600A 6R600A 1 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE FIG 5 A 11.5 B 3.5 10.5 4.5 12.5 C 3.31 D 4.00 E 3.75 F 2.25 9.25 3.00 11.00 2.25 9.25 3.00 11.00 G .62 H N/A I N/A J 5/16 HEX 3/8 HEX 5/16 HEX 3/8 HEX K .28 DIA THRU .56 DIA X .44 CBORE .28 DIA THRU .56 DIA X .44 CBORE .28 DIA THRU .56 DIA X .44 CBORE .28 DIA THRU .56 DIA X .44 CBORE L .19

FIG 5 14.00

4.31

5.00

4.50

.75

N/A

N/A

.19

Fuse Holders

FIG 5 14.50 FIG 5 17.0

3.50 3.31 10.50 4.50 4.31 12.50

7.00 8.00

3.75 4.50

.62 .75

N/A N/A

N/A N/A

.19 .19

mm = dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

FIGURE 5:
J K

D +

1 Pole

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

15

Class T Fuse Holders - 300/600 Volt+


Specifications:
RoHS Compliant
+

Fuse Holders

Tested and Approved for 200,000 Amp Withstand Rating and Short Circuit Withstand Rating UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455

Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

30 & 60 Amp
Clip, Copper Alloy, Tin Plated Patented Cool-Clip Design For box connectors, internal hex screw option available

200 Amp
Connector, One Piece Aluminum with Integral Heat Sink, Tin Plated Bolt 5/16-18 X 3/4 Hex Head, 5/16 Belleville Washer

100 Amp
Connector, One Piece Aluminum with Integral Heat Sink, Tin Plated Bolt 1/4-20 X 1/2 Bolt, 1/4 Belleville Washer

400 & 600 Amp


Connector, One Piece Aluminum with Integral Heat Sink, Tin Plated Bolt 3/8-16 X 3/4 Hex Head, 3/8 Belleville Washer

300 Volts - Catalog#:


Standard T30AXB T60AXB T100AXB T200AXB N/A T400AXB T600AXB 1 600 Reinforced Poles (X) Amps Base Materials RT30AXB RT60AXB 2/3 30 60 100 200 400 Phenolic Wire Range #2-#14 AWG CU #2-#12 AWG AL 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 250 kcmil #6 AWG CU AL (2) 500 kcmil #6 AWG CU AL

Replace X with # of poles


Fuse Size 13/32 DIA BY 7/8 9/16 DIA BY 7/8 13/16 DIA BY 2 5/32 1 1/16 DIA BY 2 7/16 1 11/32 DIA BY 2 3/4
RT60A3B

Fuses

T30A3B

A3T JJN JLLN

1/3

1 39/64 DIA BY 3 1/16

600 Volts - Catalog#:


Standard 6T30AXS 6T30AXSP 6T30AXB R6T60AXB 6T100AXB 6T200AXB N/A 6T400AXB 1 6T600AXB 600 400 Reinforced Poles (X) Amps Base Materials R6T30AXS R6T30AXSP R6T30AXB SAME 2/3 60 Phenolic 100 1/3 200 2/0-#14 AWG CU 2/0-#12 AWG AL 250 kcmil #6 AWG CU AL (2) 250 kcmil #6 AWG CU AL (2) 500 kcmil #6 AWG CU AL #2-#14 AWG CU #2-#12 AWG AL 30 Wire Range #10-#22 AWG CU #10-#14 AWG CU

Replace X with # of poles


Fuse Size 9/16 DIA BY 1 1/2 13/16 DIA BY 1 9/16 13/16 DIA BY 2 61/64 1 1/16 DIA BY 3 1/4 1 39/64 DIA BY 3 5/8 2 5/64 DIA BY 3 63/64 A6T JJS JLLS
6T30A3SP

Fuses

6T100A3B

See pages 17-18 for dimensional information


Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

R6T60A3B

16

Datasheets available at marathonsp.com

Class T Fuse Holder Dimensions


Figure T30A RT30A T60A RT60A T100A T200A 6T100A 6T200A 2 POLE 3 POLE 2 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE FIG 1 A 1.12 B C D E F G H I J SEE FIGURE #1

FIG 1

1.28 1.37 4.12 1.50 4.50 1.37 4.12 1.50 4.50

SEE FIGURE #1 N/A 2.75 N/A 3.00 N/A 2.75 N/A 3.00 0.20 THRU 0.37 DIA X .44 CBORE 0.28 THRU 0.50 DIA X .44 CBORE 0.20 THRU 0.37 DIA X .44 CBORE 0.28 THRU 0.50 DIA X .44 CBORE

Fuse Holders

FIG 2 FIG 2 FIG 2 FIG 2

5.25 7.00 6.06 7.75

1.87 2.25 1.87 2.25

4.50 6.25 5.31 7.00

0.38 0.38 0.38 0.38

0.69 0.75 0.69 0.75

3/16 HEX 5/16 HEX 3/16 HEX 5/16 HEX

.19 .19 .19 .19

mm = dim X 25.4
1.19 [30.2]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


1.19 [30.2] 1.13 [28.6] .218 THRU .39 C'BORE x .44 DP.

FIGURE 1:

2.88 [73.0]

2.25 [57.2]

1.13 [28.6] 2.38 [60.3]

.31 [7.9]

1.13 [28.6] 3.50 [88.9]

2 Pole
A

3 Pole

FIGURE 2:

.63 [15.9]
I

.50 [12.7]

.19 [4.8]

F B

G B

J C

1 Pole
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

3 Pole 17

Datasheets available at marathonsp.com

Class T Fuse Holder Dimensions


Figure T400A 6T400A 1 POLE 1 POLE 1 POLE 1 POLE 2 POLE 3 POLE 2 POLE 3 POLE FIG 3 FIG 3 A 8.12 9.00 B 2.25 2.25 C 2.37 2.37 D 7.37 8.25 E 0.38 0.38 F 1.12 1.12 G N/A N/A H 0.28 THRU 0.50 DIA X .44 CBORE 0.28 THRU 0.50 DIA X .44 CBORE 0.28 THRU 0.50 DIA X .44 CBORE 0.28 THRU 0.50 DIA X .44 CBORE I N/A N/A J .19 .19

Fuse Holders

T600A 6T600A 6T30A R6T30A R6T60A

FIG 4 FIG 4

8.75 9.75

2.75 2.75

2.62 2.62

8.06 9.00

0.34 0.38

0.38 0.38

2.00 2.00

N/A N/A

.19 .19

FIG 5 FIG 5

1.28 1.74

SEE FIGURE #5 SEE FIGURE #5


For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

mm = dim X 25.4

FIGURE 3:
H 5/16 HEX

FIGURE 4:
H 3/8 HEX

B F

D A

D A

FIGURE 5:
.78 [19.8]

3.13 [79.4] 1.56 [39.7] .78 [19.8] 1.56 [39.7]

4.69 [119.1]

.218 x .655 SLOT 3 PLS.

3.38 [85.7] 1.69 [42.9]

2 Pole

.63 [15.9]

.50 [12.7]

.19 [4.8]

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

18

Datasheets available at marathonsp.com

Class J Fuse Holders - 600 Volt+


Specifications:

+

Tested and Approved for 200,000 Amp Withstand Rating and Short Circuit Withstand Rating UL Listed File No. IZLT.E35113 (6J200, 6J400 and 6J600 fuse holders, cUL File No. 1ZLT8.E35113)

CSA Certified File No. LR21455 RoHS Compliant

Fuse Holders

Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

30 & 60 Amp
Clip, Copper Alloy, Tin Plated Patented Cool-Clip Design Integral DIN Rail Mount and Expander Block (Available only on 30 Amp) For box connectors, internal hex screw option available

200 Amp
Connector, One Piece Aluminum, Tin Plated (Optional One Piece Copper, Nickel Plated Add CU) - Consult Customer Service FBD, Fuse Bolt-Down Construction

100 Amp
Clip, Copper Alloy, Tin Plated 1-Pole Molding Incorporates a Dovetail Feature for Ganging Multiple Poles

400 & 600 Amp


Connector, One Piece Aluminum, Tin Plated (Optional One Piece Copper, Nickel Plated Add CU) - Consult Customer Service FBD, Fuse Bolt-Down Construction

Catalog#:
Standard 6J30AXS 6J30AXSP 6J30AXB 6J60AXB R6J100AXB 6J200AXBFBD SAME 6J400AXBFBD 1/3 400 Reinforced Poles (X) Amps Base Materials R6J30AXS R6J30AXSP R6J30AXB R6J60AXB 1/2/3 1 3 60 100 200 Phenolic 1/2/3/E 30 Thermoplastic

Replace X with # of poles (E = Expander)


Wire Range #10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #2-#14 AWG AL 2/0-#14 AWG CU 2/0-#12 AWG AL 350 kcmil #6 AWG CU AL (1) 350 kcmil #6 AWG CU AL (1) 600 kcmil #2 AWG CU AL (2) 500 kcmil #4 AWG CU AL Fuse Size 13/16 DIA BY 2 1/4 1 1/16 DIA BY 2 3/8 1 1/8 DIA BY 4 5/8 1 5/8 DIA BY 5 3/4 2 1/8 DIA BY 7 1/8 2 5/8 DIA BY 8
See pages 33-34 for available covers

Fuses

A4J AJT JKS JLS JTD JTD_ID LPJ

R6J30A3S

6J60A3B

6J600AXBFBD

600

Contact Customer Service for Stud Options - see pages 20-21 for dimensional information Fuse mounting hardware supplied with fuse holder

DIMENSIONS 6J30A R6J30A 6J200A 6J60A R6J60A 6J400A 6J600A R6J100A 1 POLE 2 POLE 3 POLE 1 POLE 3 POLE 1 POLE 2 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE 1 POLE 3 POLE

Figure

B 1.16 2.20 3.25

C 1.95

D 1.69

E 1.04

H .22 X .79 SLOT

M 0.24

EXPANDER YES

6J600A3BFBD

FIG 1 3.38 (p. 20)

0.30 0.57

SEE FIGURE #2 (page 20)

SEE FIGURE #3 (page 20) SEE FIGURE #4 (page 21) SEE FIGURE #5 (page 21) SEE FIGURE #6 (page 21)
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

mm = dim X 25.4
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

19

Class J Fuse Holder Dimensions


FIGURE 1:
.22 x .79 SLOT

M 0.24
1.04 0.30 0.57

DEPTH OF MOUNTING SLOT

Fuse Holders

D
1.69

A 3.38

Expander

1.16

2.20

3.25

1.95

1 Pole

2 Pole

3 Pole

FIGURE 2:

5/16 HEX DRIVE

.34 THRU [ 8.6] CB .75 X .40 DP [ 19.1 X 10.2] 4X

5/16 HEX DRIVE

3.25 [82.6]

1.69 [42.9] .69 [17.5] 2.00 [50.8] 2.41 [61.1]

1/4-20 STUD TYP.

6.50 [165.1]

3.38 [85.7]

1.00 [25.4]

7.00 [177.8] 9.00 [228.6] 2.83 [71.8]

.63 [15.9]

1 Pole
FIGURE 3:
1.67 [42.4] 3.20 [81.2]

3 Pole
.265 X.327 SLOT [6.7 X 8.3] TYP.

4.72 [119.9]

4.07 [103] 2.03 [51.7]

.45 [11.5] .76 [19.4]

1.53 [38.8]

.13 [3.2] 2.09 [53.0]

1 Pole

2 Pole

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

20

Datasheets available at marathonsp.com

Class J Fuse Holder Dimensions


FIGURE 4:
.34 THRU [8.6] CB .75 X .44 DP [19.1 X 11.2] 4X 1.69 [42.9] 2.81 [71.4] TYP. 5/16 HEX DRIVE 1/2 HEX DRIVE 3.13 [79.4]

2.00 [50.8] TYP. .75 [19.1] 2.00 [50.8] 4.50 [114.3] TYP. 3/8-16 STUD TYP. 1.75 [44.5] 3.50 [88.9] 1.50 [38.1] 6.00 [152.4] 9.00 [228.6] .63 [15.9] 5.25 [133.4] 11.00 [279.4]

Fuse Holders

1 Pole
FIGURE 5:
2.00 [50.8] 4.00 [101.6]

3 Pole
3/8 HEX DRIVE TYP. 2.00 [50.8] 4.00 [101.6] TYP. .34 THRU [8.6] CB .75 X .44 DP [19.1 X 11.2] 4X

2.88 [73] TYP.

6.00 [152.4]

11.75 [298.5]

4.44 [112.7] TYP.

1.13 [28.6] 1.75 [44.5]

.50 [12.7]

11.00 [279.4] 12.00 [304.8]

1/2-13 STUDS TYP. .63 [15.9] 3.63 [92.1]

1 Pole
FIGURE 6:
.27 [6.7] 2.14 [54.3]

3 Pole
5.36 [136.2] 1.50 [38.1] .28 [7.1] THRU CB .53 [13.5] SLOT .53 X .28 [13.5 X 7.1] CB 1.06 X .53 [26.9 X 13.5] 1.93 [49.1] 1.50 [38.1]

5.13 [130.2] TYP. 2.56 [65.1]

2.56 [65.1]

2.63 [66.7]

1.00 [25.4] REF.

Integral dovetail features for multi-line stackup. (For 1-Pole thermoplastic block only.)

1 Pole
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

3 Pole
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

21

Class J Enclosed Fuse Holders 600 Volt


Specifications:
Tested and Approved for 200,000 Amp Short Circuit Withstand Rating
Touchsafe IEC Type Design (IP20)

Fuse Holders

RoHS Compliant

Blown fuse indicating type available (6SJ30AXI and 6SJ60AXI) Red dual LED indicator - range of operating voltage 110-600V AC/DC, use either polarity for DC application UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455
Shown left to right: 6SJ30A3I, 6SJ60A

Catalog#:
Standard 6SJ30AX 6SJ30AXI 6SJ60AX 6SJ60AXI Poles (X) 1/2/3 Amps 30 Thermoplastic 1/2/3 60 Base Materials Wire Range #1 - #18 AWG or (2) #10-18 AWG

Replace X with # of poles


Fuse Size 13/16 DIA BY 2 1/4 1 1/16 DIA BY 2 3/8 Fuses A4J, AJT JKS, JLS, JTD, JTD_ID, LPJ

same size & construction

same size & construction

#1 - #10 AWG or (2) #6-10 AWG

30 AMPS:

2.84 72.1

4.61 117

2.56 65.1

1.42 36

2.83 72

4.25 108

1 Pole
60 AMPS:
3.11 79

2 Pole

3 Pole

4.57 116

3.39 86

1.57 40

3.15 80

4.72 120

1 Pole
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

2 Pole

3 Pole
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

22

Datasheets available at marathonsp.com

M Fuse Holders - 600 Volt+


Specifications:
Tested and Approved for 100,000 Amp Withstand Rating and Short Circuit Withstand Rating Clip, Copper Alloy, Tin Plated Quick Connect Standard with Screw (S) or Sems Pressure (SP) UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455 - Rated for 1000 Volts RoHS Compliant
+ Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Fuse Holders

6M30A3SPQ

6M30A3B

Catalog#:
Standard 6M30AXSQ 6M30AXSPQ N/A 6M30AXB #6-#14 AWG CU 6M30AXBCU
See pages 33-34 for available covers See page 35 for DIN Rail Adapter

Replace X with # of poles


Wire Range #10-#22 AWG CU #10-#14 AWG CU 1/2/3 30 Thermoplastic Fuse Size Fuses A13X-2, A25Z-2, A60Q-2, A6Y-2B, AGU, 13/32 DIA BY 1 1/2 ATM, ATQ, BAF, BAN, BLF, BLN, BLS, FLA, FLM, FLQ, FNM, FNQ, GFN, GGO, KLK, KLKD, KLQ, KTK, OTM, TRM
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Reinforced Poles (X) Amps Base Materials

.18 x .59 SLOT

M
0.75

0.09

0.24

0.38

DEPTH OF MOUNTING SLOT

D 1.56 A
3.13

0.85

1.60

2.35

1.29

1 Pole

2 Pole

3 Pole

mm = dim X 25.4
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

23

Midget Enclosed Fuse Holders 600/1000 Volt


Specifications:
Touchsafe IEC Type Design (IP20) DIN Rail Mount (35mm - symmetrical) Blown Fuse Indication Available Handle Allows Quick Easy Fuse Change UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455

Fuse Holders

RoHS Compliant

Shown left to right: 6SM30A3-D, 10SM30A1I-D, 6SM30A1I-D

600 Volts:
Tested and Approved for 50,000 RMS Amps Short Circuit Withstand Rating Base Materials, Thermoplastic AC & DC Rated 30 Amps, 600 V Red dual LED indicator range of operating voltage 110-690V AC/DC, use any polarity for DC application
Catalog # 6SM30AX-D 6SM30AXI-D Indicating Poles No Yes 1 2 3 4 Wire Range #4-#18 AWG CU or
same size & construction

(2) #6-#18 AWG

Replace X with # of poles

1000 Volts:
Red LED indicator range of operating voltage 400-1000V DC Base Materials, Thermoplastic 30A, 600 V DC, UL/CSA 32A, 1000V DC, IEC (for Photovoltaic applications)
Fuse Size 13/32 DIA BY 1 1/2 (10x38) Fuses A13X-2, A25Z-2, A60Q-2, A6Y-2B, AGU, ATM, ATQ, BAF, BAN, BLF, BLN, BLS, FLA, FLM, FLQ, FNM, FNQ, GFN, GGO, KLK, KLKD, KLQ, KTK, OTM, TRM Catalog # 10SM30AX-D 10SM30AXI-D Indicating Poles No Yes 1 2 3 4 Wire Range #4-#18 AWG CU or
same size & construction

(2) #6-#18 AWG

Fuses for PV Systems (1000V) PV-A10F SPF DCT

2.23 56.6

3.29 83.5

2.47 62.6

.71 18

1.42 36

2.13 54

2.83 72

1 Pole

2 Pole

3 Pole

4 Pole
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

24

Datasheets available at marathonsp.com

Midget Fuse Holders - 600 Volt


30 Amp Sectional Version
Specifications:
Tested and Approved for 10,000 Amp Withstand Rating and Short Circuit Withstand Rating Base, White Nylon - Type 6/6, 105oC Connector Box Type Accepts up to #10 AWG Wire, either Terminated or Non-Terminated Clip, Copper Alloy, Tin Plated UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455

Fuse Holders

RoHS Compliant

6W30A1F with end piece (fuse not included)

Standard 6W30A1F 6W30A1C 6WEF 6WEC MC MPC-6 MPC-3 GR-2

Description Flat Mount Channel Mount End Piece (flat) End Piece (channel) Mounting Clamp 6 Foot Channel 3 Foot Channel 1/8 Diameter X 2 Long Nylon Rod

Std Pack

Wire Range

Fuse Size

Fuses A13X-2, A25Z-2,

10 #10-#14 AWG CU 25 STRANDED 13/32 DIA BY 1 1/2 (10x38)

A60Q-2, A6Y-2B, AGU, ATM, ATQ, BAF, BAN, BLF, BLN, BLS, FLA, FLM, FLQ, FNM, FNQ, GFN, GGO, KLK, KLKD, KLQ, KTK, OTM, TRM

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


"L"

Flat Mount: L = 0.88 + (0.68 X N) C = 0.48 + (0.68 X N) N = No. of Poles Channel Dimensions: LCH = L + 2.25

.34 [8.6]

"C"

.21 [5.3]

1.00 [25.4]

2.00 [50.8]

.68 [17.4]

.17 [4.3]

2.80 [71.1]

1.95 [49.5]

SPECIAL PRODUCTS

1.70 [43.2]

2.03 [51.6]

.40 [10.2]

.08 [2.0]

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

.88 [22.4]

Datasheets available at marathonsp.com

25

97949

2.00 [50.8]

13/32 x 1-1/2 FUSE

CC Fuse Holders - 600 Volt


Specifications:
30 Amp
Tested and Approved for 200,000 Amp Withstand Rating and Short Circuit Withstand Rating Clip, Copper Alloy, Tin Plated with Patented Reject Member Quick Connect Standard with Screw (S) or Sems Pressure (SP) For box connectors, internal hex screw option is available UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant

60 Amp
Tested and Approved for 200,000 Amp Withstand Rating and Short Circuit Withstand Rating Patented Cool-Clip Design Clip, Copper Alloy, Tin Plated Integral DIN Rail Mount Expander Block Available For box connectors, internal hex screw option is available UL Listed File No. IZLT2.E35113, Class CD CSA Certified File No. LR21455-91 RoHS Compliant

Fuse Holders

6CC30A3SQ

Catalog#:
Standard 6CC30AXSQ 6CC30AXSPQ N/A 6CC30AXB 6CC30AXBCU R6CC60AXB SAME 1/2/3/E 60 1/2/3 30 Thermoplastic Reinforced Poles (X) Amps Base Materials

Replace X with # of poles (E = Expander)


Wire Range #10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU #2-#14 AWG CU #2-#12 AWG AL 0.70 DIA BY 1.85 CLASS CC ONLY Fuse Size Fuses ATDR, ATMR ATQR, CCMR FNQ-R KLDR, KLKR, KTK-R, LP-CC CCMR
R6CC60A3B 6CC30A3B

See pages 33-34 for available covers See page 35 for DIN Rail Adapter

M E F G DEPTH OF MOUNTING SLOT

D A

1 Pole
DIMENSIONS

2 Pole
A 3.13 B 0.85 1.60 2.35 1.11 2.12 3.12 C 1.29 D 1.56 1 POLE 2 POLE 3 POLE 1 POLE 2 POLE 3 POLE

3 Pole
E 0.75 F G H .18 X .59 SLOT .18 X .74 SLOT M 0.09 EXPANDER NO

Expander

6CC30A

0.24 0.38

R6CC60A

3.35

1.89

1.68

1.01

0.27 0.57

0.09

YES

mm = dim X 25.4
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

26

Datasheets available at marathonsp.com

Class CC Enclosed Fuse Holders - 600 Volt


Specifications:
Tested and Approved for 200,000 Amps Short Circuit Withstand Rating Touchsafe IEC Type Design (IP20) DIN Rail Mount (35mm - symmetrical) Blown Fuse Indication Available Red dual LED indicator - range of operating voltage 110-600V AC/DC, use either polarity for DC application Handle Allows Quick Easy Fuse Change UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455
6SC30A3I-D 6SC30A1I-D shown with fuse (fuse not included) 6SC30A1I-D

Fuse Holders

RoHS Compliant

Catalog # 6SC30A1-D 6SC30A2-D 6SC30A3-D 6SC30A4-D 6SC30A1I-D 6SC30A2I-D 6SC30A3I-D 6SC30A4I-D

Indicating Poles (X) Amps Base Materials 1 No 2 3 4 1 Yes 2 3 4 30 Thermoplastic

Wire Range

Fuse Size

Fuses ATDR ATMR

#4-#18 AWG CU or
same size & construction

ATQR CLASS CC ONLY CCMR FNQ-R KLDR KLKR KTK-R, LP-CC

(2) #6-18 AWG

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

2.23 56.6

3.29 83.5

2.47 62.6

.71 18

1.42 36

2.13 54

2.83 72

1 Pole

2 Pole

3 Pole

4 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

27

Class G Fuse Holders


Specifications: Tested and Approved for 100,000 Amp Withstand Rating and Short Circuit Withstand Rating Clip, Copper Alloy, Tin Plated Quick Connect Standard with Screw (S) or Sems Pressure (SP) For box connectors, internal hex screw option available UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455

Fuse Holders

RoHS Compliant

1/2 - 15 Amps (600 Volt)


Catalog # Standard Reinforced Poles (X) Amps Base Materials

Replace X with # of poles


Wire Range Fuse Size Fuses

G15AXSQ G15AXB

RG15AXSQ RG15AXB 1/2/3 15 Thermoplastic

#10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU 13/32 DIA BY 1 5/16

G15AXSPQ RG15AXSPQ G15AXBCU RG15AXBCU

AG SC SLC
G15A3SPQ

20 Amps (600 Volt)


Catalog # Standard Reinforced Poles (X) Amps Base Materials Wire Range Fuse Size Fuses

G20AXSQ G20AXB

RG20AXSQ RG20AXB 1/2/3 20 Thermoplastic

#10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU

G20AXSPQ RG20AXSPQ G20AXBCU RG20AXBCU

13/32 DIA BY 1 13/32

AG SC SLC
G20A3SQ

25-30 Amps (480 Volt)


Catalog # Standard Reinforced Poles (X) Amps Base Materials Wire Range Fuse Size Fuses

G30AXSQ G30AXB

RG30AXSQ RG30AXB 1/2/3 30 Thermoplastic

#10-#22 AWG CU #10-#14 AWG CU #6-#14 AWG CU

G30AXSPQ RG30AXSPQ G30AXBCU RG30AXBCU

13/32 DIA BY 1 5/8

AG SC SLC
G30AXB

See pages 33-34 for available covers See page 35 for DIN Rail Adapter

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

M H
.18 x .59 SLOT

0.09

E
0.75

F
0.24 0.38

DEPTH OF MOUNTING SLOT

D 1.56 A
3.13

0.85

1.60

2.35

1.29

C
mm = dim X 25.4

1 Pole

2 Pole 28

3 Pole

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

Semi Conductor Fuse Holders 600 Volt


Box Version - Specifications:
200,000 Amp Withstand Rating Insulator Base, General Purpose Phenolic, 150oC (UL RTI) Hex-Head Bolts and Belleville Washers Provided Unassembled Connector - Aluminum, Tin Plated Dove-tail Interlocking Feature on 1MS101 Two-piece Modular Design UL Recognized File No. IZLT2.E35113 RoHS Compliant

Fuse Holders

1MS101

1MS104

Catalog # 1MS101 1MS102 1MS103 1MS104

Maximum Amperage 100 400 400 600

Wire Range 2/0 - #14 (2) 250 kcmil - #6 (2) 250 kcmil - #6 (2) 500 kcmil - #6

Tested At: Ip I2t 193 kA 3480 kA 3480 kA 2840 kA 27.4 kA 69.5 kA 69.5 kA 50.8 kA

NOTE: Order two blocks per fuse


2.13 [54.1] SLOT .20 X .30 .47 [12.0] .27 [6.9] 3/16 HEX 1/4-20 .88 [22.2] 1.75 [44.5]
3.12 [79.2]

.56 [14.3]

2.25 [57.2]

.75 [19.1]

SLOT .29 X .39 1/4-20

5/16 HEX

2.40 [61.0]

1MS101
3.12 [79.2] .56 [14.3]
2.85 [72.4]

1MS102
4.00 [101.6]

2.25 [57.2]

.75 [19.1]

SLOT .29 X .39 3/8-16

1.06 [27.0]

SLOT .29 X .39

3/8-16

5/16 HEX

2.40 [61.0]

3/8 HEX

3.28 [83.2]

1MS103
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

1MS104
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

29

Semi Conductor Fuse Holders 1000 Volt


Stud Version - Specifications:
Fuse Holders
Insulator Base, High Strength Thermoplastic Stud, Nuts and Belleville Washers: Plated Steel Maximum Insulator Base Temperature Rating 125oC (257oF) UL RTI (impact) Hardware Provided Unassembled Flammability Rating of Insulator UL 94 V-0 Ideal for applications such as lithium-ion battery packs, inverters, industrial panels and other energy storage devices UL Recognized File No. IZLT2.E35113 RoHS Compliant
Shown left to right: FSM50E, FSM37E, FSM25E

FSM25E Stud Sizes Electrical Ratings Application Torque Withstand Rating Mounting 1/4-20 Stud

FSM37E 3/8-16 Stud

FSM50E 1/2-13 Stud

Metric sizes (M6, M10, M12) available upon request - contact Customer Service for more information 400A, Up to 1000V AC/DC 75 in-lbs Approved for 200,000A, Tested at 111 kA2s (I2t) and 20.0 kA (Ip) Mount with #10 fastener, torque to 25-30 in. lbs. 800A, Up to 1000V AC/DC 230 in-lbs Approved for 200,000A, Tested at 274 kA2s (I2t) and 26.2 kA (Ip) Mount with #10 fastener, torque to 25-30 in. lbs. 1200A, Up to 1000V AC/DC 300 in-lbs Approved for 200,000A, Tested at 465 kA2s (I2t) and 30.8 kA (Ip) Mount with 1/4 fastener, torque to 25-30 in. lbs.
2.13 54
2.13 54
.21 5.4 1.00 25.4 1.28 32.5

NOTE: Order two blocks per fuse


1.28 32.5
1.59 40.5

.20 5.2

.70 17.8

1.49 37.7

.29 7.4

.29 7.4

1.49 37.7

.30 7.7

.20 5.2

.31 7.8

10.5

.42 10.5 .42

.70 17.8

1/4-20 UNC 2A 1.09 27.7 REF.


.30 7.7

3/8-16 UNC 2A 1.16.03 29.30.8 REF.

1/2-13 UNC 2A
1/2-13 UNC 2A

2.47 62.7

.70 17.8 2X

1/4-20 UNC 2A 1.09 27.7 REF. 1.38 34.9 3.60 91.3 .70 17.8 2X

1.00 25.4

2.00 2.00 50.8 50.8 REF. 5.27 5.27 133.7 133.7

REF.

1.39 35.2 35.2

1.39

2.47 62.7

.26 6.6

2.44 62

3.27 3.27 82.9 82.9

.01 0.3 REF.

1.38 34.9

1.89 48

.26 6.6

.26 6.6

.39 .39 9.8

9.8

.01 0.3 REF.

1.89 48

.01 0.3

2.13 54

.010.3 0.3

.01

2.83 71.9 71.9

2.83

FSM25E
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

FSM37E

FSM50E
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

30

Datasheets available at marathonsp.com

Fuse Holders with BD (Box Distribution) Connectors


30 and 60 Amp 250 and 600 Volt
Specifications:
Available on Class H, R and J Fuse Holders Connectors, High Conductive Aluminum, Tin Plated Reinforcing Member Available, Standard on Class R UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455 RoHS Compliant

Fuse Holders

Class H and R Fuse Holders


Catalog # F60AXBD R60AXBD F60AXBD-D R60AXBD-D 6F30AXBD-D 6R30AXBD-D 6F60AXBD 6R60AXBD 6F60AXBD-D 6R60AXBD-D
Class R - No Agency Approval

Replace X with # of poles


Load Wire Range (1) #2 - #10 AWG (1) #6 - #14 AWG
F60A3BD

Volts

Amps

Line Wire Range

250

60

(1) #2 - #10 AWG

30 600 60

(1) #6 - #14 AWG

(1) #6 - #14 AWG (2) #10 - #18 AWG (1) #2 - #10 AWG (1) #6 - #14 AWG (1) #2 - #10 AWG (2) #6 - #14 AWG

(1) #2 - #10 AWG

6F30A3BDD

Class J Fuse Holders


Catalog # 6J60AXBD 600 6J60AXBD-D
Class J - No Agency Approval

Replace X with # of poles


Line Wire Range Load Wire Range (1) #2 - #10 AWG (1) #6 - #14 AWG (1) #2 - #10 AWG (2) #6 - #14 AWG
6J60A3BDD

Volts

Amps

60

(1) #2 - #10 AWG

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

31

STSF Forklift/Semi Conductor Fuse Holder


Stud Version - Specifications:
Fuse Holders
Base, High Strength Thermoplastic Temperature Rating of 170oC Studs, Stainless Steel (Nuts and Washers Provided) 130 Volt AC/DC, 1 to 400 Amps UL Recognized File No. IZLT2.E35113 RoHS Compliant

Applications:
This holder is used in direct current (DC) applications: forklifts, golf carts, electric vehicles, custom high-end car stereo systems, heavy equipment, marine aircraft, and similar applications.
ST SF

3.41 [86.5] .48 [12.3] 1.20 [30.6] .50 [12.7] 2.44 [61.9] 1.00 [25.4] .47 [11.9] .94 [23.8]

.235/.225 .50 C'BORE X 82 (2)HOLES

5/16-18 STUD

1.64 [41.6] .48 [12.3]

.30 [7.5]
A #10 flat or conventional pan head screw head is acceptable. For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

32

Datasheets available at marathonsp.com

Fuse Holder Covers


Specifications:
Material, Thermoplastic Thermal Rating, 125oC (RTI, per UL 746) Flammability, VO (per UL 94) UL Listed Accessories under File No. JDVS2.E181825 In Application, Protection is Consistent with IEC Standard 529, Designation IP20 (Finger Safe)* - except CJ6100-1, CJ6100-2, and CJ6100-3 Opening Allows View of Self-Indicating Fuses Holes for Test Probes and Re-tightening of Wire Terminations Covers fit most Fuse Holder Brands RoHS Compliant

Fuse Holders

Catalog # CHR230 CHR260 CHR2100 CHR630 CHR660 CHR6100 CJ630 CJ660 CC630 CC660 CCM630** CJ6100-1C CJ6100-2C CJ6100-3C

For use w/Fuse Holder # Fuse Type Voltage F30A/R30A F60A/R60A RF100A/R100A 6F30A/6R30A 6F60A/6R60A R6F100A/6R100A 6J30A 6J60A 6CC30A, Class G R6CC60A 6M30A/6CCM30A R6J100A R6J100A R6J100A H/R H/R H/R H/R H/R H/R J J CC, G CD MISC J J J 250 250 250 600 600 600 600 600 600 600 600 600 600 600

Amp 30 60 100 30 60 100 30 60 30 60 30 100 100 100


*Applications involving fuse holders other than Marathon may not provide IP20 finger protection **Covers are recognized if used with recognized fuses Fuse Holder shown with Covers Attached

See page 34 for dimensional information

Cover/Puller (Catalog # CVR-MCC)


Marathons Cover/Puller was designed for use with the Class CC (30 Amp), Midget and Class G (15 & 20 Amp only) Fuse Holders. Once installed, the Cover/Puller provides an easy and safe way to remove fuses. In application, protection is consistent with IEC Standard 529, designation IP20 (finger safe).

3.50 1.05 .62

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

Datasheets available at marathonsp.com

33

Fuse Holder Covers


Catalog # CHR230 CHR260 CHR2100 CHR630 CHR660 CHR6100 CJ630 CJ660 CC630 CC660 CCM630 CJ6100-1C CJ6100-2C CJ6100-3C Figure FIG 1 FIG 1 FIG 2 FIG 1 FIG 1 FIG 2 FIG 1 FIG 1 FIG 3 FIG 1 FIG 3 FIG 4 FIG 4 FIG 4 A 3.76 5.80 7.38 7.56 8.30 9.34 4.30 5.04 3.83 4.58 3.83 1.94 3.94 5.22 B 1.67 2.16 2.41 1.71 2.37 2.45 1.95 2.07 1.69 1.95 1.69 1.38 3.38 4.66 C 0.86 1.07 1.49 1.10 1.35 1.49 0.90 1.35 0.74 0.90 0.74 D 2.54 3.66 4.90 5.58 6.32 6.90 2.66 3.10 2.34 2.66 2.34 E 0.40 0.47 0.38 0.47 0.35 0.38 0.35 0.35 0.34 0.35 0.34 F 0.30 0.42 0.46 0.42 0.42 0.46 0.30 0.42 0.30 0.42 0.30 (2 mounting screws supplied) (2 mounting screws supplied) (4 mounting screws supplied)

Fuse Holders

mm = dim X 25.4
E

C
C

FIGURE 1:
E

FIGURE 2:

A
C

.28 REF. [7.1] .13 TYP. [3.2]

2.00 [50.8]
B

3.13 [79.4]

4.75 [120.7]

1.38 [34.9]
F A

.81 [20.6]

FIGURE 3:
Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

FIGURE 4:

34

Datasheets available at marathonsp.com

DIN Rail Adapters


DIN R 1:
Accessory to Secure Surface Mount Devices on DIN Rail Made of Acetal Resin Material High Mechanical Strength and Rigidty Good Resilience and Resistance to Creep Excellent Dimensionial Stability Excellent Low Temperature Toughness Wide End-Use Temperature Range Will Work with 2 and 3 pole Class H (250 Volt, 30 Amp) and Class R Fuse Holders (250 Volt, 30 Amp), and 985, 1100, 1200, 1500, 1600 and 1700 Series Heavy Duty Terminal Blocks RoHS Compliant

Fuse Holders

USE A #8 SELF TAPPING SCREW FOR MOUNTING COMPONENT

Assembly Method:
Press Adapter onto Rail, Fasten Component with #8 Self Tapping Screw (Screw not Supplied) Assembly Locks Firmly unto DIN Rail

Catalog # DIN R 1

Std Pack Qty 10

DIN R 2:
For use with Class CC (30 Amp), Midget, and Class G Fuse Holders. RoHS Compliant
[37.85] 1.490

[19.05] 0.750

[14.63] 0.576

[19.56] 0.770

Assembly Method:
DIN R 2 snaps securely to the Marathon Fuse Holders and to DIN Rails without Tools, which Permits the Fuse Holders to be Mounted Directly to Standard and Low Profile 35mm Symmetrical and 32mm Asymmetrical DIN Rails. May be Removed by Lifting the Disconnect Tab

[12.29] 0.484 [17.02] 0.670 [34.54] 1.360

Catalog # DIN R 2

Std Pack Qty 10

Marathon Special Products fuse holders comply to new harmonized fuse holder standard 4248. Please refer to www.marathonsp.com for the latest updates.

35

Power Distribution Blocks with SCCR and Feeder Spacing


SCCR Information:
Short-Circuit Current Ratings and Feeder Spacing
The requirements of the National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short Circuit Current Rating (SCCR). Analyzing the SCCR of individual components and overcurrent protection devices is a method of determining the SCCR of an electrical assembly. Marathons Recognized and Listed Power Blocks been used in electrical control panels for over 35 years. These blocks have now been tested and approved for higher SCCR. The higher ratings are based on proper wire sizes and the appropriate circuit protection device (fuses or circuit breakers). UL508A does allow default SCCR for Power Distribution Blocks of 10,000A with no additional testing. For detailed SCCR product information, please visit www.marathonsp.com/PDFs/SCCR.pdf

Feeder Spacing/Adapter Plates for Feeder Spacing:


Recently, the National Electric Code (NEC) and UL508A began requiring that Power Blocks used in Feeder Circuits must carry voltage spacing greater than the traditional Industrial Control requirements. Marathon offers Power Blocks solutions that meet feeder spacing requirements. Marathons Listed Power Distribution Blocks cover a range of small to large wire termination capabilities and meet the requirements for use in feeder circuits per UL508A up to 600V. We also offer a line of adapter plates for Marathons Recognized Power Blocks that allow the customer to mount three single-line Power Blocks on a base which assures the requirements of feeder spacing are met.
POWER BLOCKS

Adapter Kit Catalog # FBA 132 FBA 133 FBA 138 FBA 141 FBA 142 FBA 143 FBA 145

Power Block Series 132 Series 133 Series EPB Series 141 Series 142 Series 143 Series 145 Series

ADAPTER PLATE

ASSEMBLE WITH SCREW AS SHOWN

36

UL Listed Power Distribution Blocks


The requirements of the National Electric Code (NEC) and UL508A now require many electrical panels to carry a

UL Listed Power Distribution Blocks

Short Circuit Current Rating (SCCR). These new Power Distribution Blocks are listed to UL1953. The feeder spacing requirements of UL508A are achieved with these blocks.
Shown left to right: FPB23570 and FPB33588

Specifications:
Connector Housings, Thermoplastic, UL 94 V-0, RTI 125oC Insulator Base Plate, Phenolic Laminate, UL 94 V-0, RTI 130oC Wire Connectors - Tin Plated Aluminum, Rated for Copper or Aluminum Wire (CU & AL) Short Circuit Current Rating up to 100kA (100kA SCCR Rating with copper conductors only. Requires specific over-current protection device.) Flexible Stranded Wire Compliant Safety hinged cover available as accessory, 1 cover per pole (CH1321 and CH1331) - see page 58 UL 508A Feeder Circuit Terminal Spacing for up to 600 Volts Rated up to 335 Amp, 600 Volts Line side conductor up to 600 kcmil Distribution, up to twelve conductors per pole Investigated to UL 1953 UL Category and File: QPQS.E309401 RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

To order blocks with cover installed, add CH to end of part number - if ordered with cover installed, blocks are UL Recognized LINE SIDE Catalog # FPB23570 Current Amps (CU) 175 Connector Material Aluminum Wire Range AWG/kcmil 2/0 - #14 Openings Per Pole 1 Connector Wire Range Config. AWG/kcmil #4 - #14 LOAD SIDE Openings Per Pole 4 SCCR RMS Connector Sym Amps Config. 600 volt Max 100,000

FPB23572

175

Aluminum

2/0 - #14

2/0 - #14

100,000

FPB23574

175

Aluminum

2/0 - #14

1/4 - 20 stud

100,000

FPB23580

175

Aluminum

2/0 - #14

#4 - #14

100,000

FPB33553

335

Aluminum

400 kcmil - #6

#2 - #14

100,000

FPB33588

335

Aluminum

600 kcmil - #2

1/0 - #14 #2 - #14

3 6

100,000

FPB33595

335

Aluminum

600 kcmil - #2

#4 - #14

12

100,000

See page 38 for dimensional information.

37

UL Listed Power Distribution Blocks


FPB23XXX
4.25 108 3.05 77.3 .38 9.5 1.31 33.3 1.63 41.3

UL Listed Power Distribution Blocks

3.00 76.2

2.25 57.2

PRODUCT & SCCR INFORMATION PROVIDED ON SIDES OF BLOCK

.22 [5.6] THRU CB .50 X .38 DP 4X [12.7 X 9.7 DP]

FPB33XXX
.38 9.5 1.38 34.9

6.00 152.4 3.96 100.5 3.25 82.5

5.50 139.7

4.75 120.6

PRODUCT & SCCR INFORMATION PROVIDED ON SIDES OF BLOCK

.22 [5.6] THRU CB .50 X .38 DP 4X [12.7 X 9.7 DP]

38

Datasheets available at marathonsp.com

UL Listed Power Distribution Blocks


Specifications:
Provides feeder circuit terminal spacing up to 1 through air and 2 over surface Rated for 600 Volts (AC/DC) per UL508A, Section 10 Amperage Ratings up to 950A for copper wire and 770A for aluminum wire Line side accepts up to (2) 750 kcmil wires, per phase Load side accepts up to (2) 750 kcmil, (6) 250 kcmil, (8) 3/0 or (10) 2/0 wires, per phase Rated for flexible stranded copper wire (UL Class G/H/I/DLO) as well as copper and aluminum code wire (UL Class B/C) High-impact resistant thermoplastic insulator base, flame retardant and heat resistant Rated UL 94-V-0 UL Temperature Rating 125oC Mounting: panel mount

UL Listed Power Distribution Blocks

Shown: 1351708 (UL Listed) and 1353702 with accessory cover (UL Recognized)

Safety hinged cover available (CH 1351), 1 cover per pole - p. 58 UL Listed, Investigated to UL 1953, File QPQS.E309401 Short Circuit Current Ratings (SCCR) up to 100,000 SYM Amps CSA Certified (pending), CSA 22.2 No. 158, File 019766_0_000 RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

To order blocks with cover installed, add CH to end of part number - if ordered with cover installed, blocks are UL Recognized
CATALOG # Without Cover 1351701 1352701 1353701 1351702 1352702 1353702 1351703 1352703 1353703 1351704 1352704 1353704 1351705 1352705 1353705 1351706 1352706 1353706 1351707 1352707 1353707 1351708 1352708 1353708 MATERIAL Wire Range Poles Amps Insulator Connector AWG/kcmil 1 2 Aluminum 750 kcmil Plastic 475 1/0 AWG 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 950 Plastic Aluminum 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG LINE SIDE Openings Connector per Pole Config. 1 Wire Range AWG/kcmil 750 kcmil 1/0 AWG 750 kcmil 1/0 AWG 250 kcmil 6 AWG 2/0 - 14 AWG 2-14 AWG 250 kcmil 6 AWG 2-14 AWG 250 kcmil 6 AWG 2-14 AWG 3/0 - 6 AWG 3/0 - 6 AWG LOAD SIDE SCCR, RMS Openings Connector SYM Amps per Pole Config. 600 Volt Max 1 100,000

100,000

950

Plastic

Aluminum

6 10 12 3 4 5 12 4 8

100,000

950

Plastic

Aluminum

100,000

950

Plastic

Aluminum

100,000

950

Plastic

Aluminum

100,000

950

Plastic

Aluminum

100,000

950

Plastic

Aluminum

100,000

3 POLE
10.10 256.6

2 POLE
6.79 172.5

1 POLE
3.48 88.3

SIDE VIEW WITHOUT COVER


1.52 38.5 4.53 114.9

4.75 120.7

5.75 146.1

on . .28 [7.1] THRU CB .63 [15.9] X .37 [9.4] DP

2.69 68.2 3.94 100 7.87 200 3.31 84.1 .63 15.9

2.06 52.4 3.31 84.1 4.56 115.9

1.25 31.8 .63 15.9

Product & SCCR information provided on sides of block.

.28 [7.1 CB .63

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

39

UL Listed Enclosed Power Distribution Blocks


Specifications:
UL Listed Enclosed Power Distribution Blocks
Electrical 600 Volts AC/DC+ 1000 Volts (IEC) Up to 115 Amps Wire Range #2 to #14 Flexible Stranded Wire Compliant Mechanical Base, Gray Thermoplastic, 125oC (257oF) (UL RTI) Flammability, UL 94 V-0 Mounting: DIN or panel mount
+ Refer to www.marathonsp.com/ PDFs/ 1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Standards UL Listed File No. QPQS.E309401 (UL 1953) CSA Certified File No. LR19766 (CSA C22-2 No. 158) (Component IEC 60947-7-1) IEC 60529, IP-20 RoHS Compliant Accessories (consult Cust. Service) White Markers to Identify Circuits DIN Rail for Mounting Option End Piece for DIN Rail (MSK35)
Shown left to right: EPBAD24, EPBAD21

LINE SIDE Catalog # EPBAD21 Amps 115 Wire Range AWG/kcmil #2 - #14 AWG 35 - 2.5 mm2 Openings Per Pole Connector Configuration Wire Range AWG/kcmil #2 - #14 AWG 35 - 2.5 mm2

LOAD SIDE Openings Per Pole Connector Configuration

SCCR, RMS SYM Amps 600 Volt Max

100,000

EPBAD24

115

#2 - #14 AWG 35 - 2.5 mm2

#10 - #14 AWG 6 - 2.5 mm2

65,000

Ordering Code:

EPB

A
Connector Material: A - Aluminum rated copper or aluminum wire

21
STACK-UP DIMENSIONS (If Dovetail is used for Multi-Line) SLOT .31 X .21, [7.9 X 5.3] FOR USE WITH #10 MTG SCREW 5/32 [4mm] HEX DRIVE DOVETAIL FEATURES ON SIDES OF BLOCK FOR MULTI-LINE STACK-UP (SEE NOTE-6) 5/64 [2mm] HEX DRIVE TYP. FOR SNAP-IN MARKER CARDS SCCR RATINGS & ENGLISH & METRIC WIRE RANGES W/TORQUE PRINTED ON OPPOSITE SIDE OF BLOCK. .10 2.6 .75 19 .75 18.9 TYP. 1.49 37.8 2.24 56.8 .37 9.5 1.49 37.9

21 - (1) #2 to (1) #2 D - Mount on 24 - (1) #2 to (4) #10 35 mm DIN rail or flat panel
1.71 43.5

Note: 1) 2) 3) The ampacities are based on Table 310-16 of the NEC. The connectors were tested and approved per UL 486 A/B. For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

4.14 105.2

3.75 95.3

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

40

Datasheets available at marathonsp.com

UL Listed Enclosed Power Distribution Blocks


Specifications:
Electrical 600 Volts AC/DC (UL 1953)+ 1000 Volts (IEC) Up to 200 Amps Wire Range 3/0 to #14 Flexible Stranded Wire Compliant Mechanical Base, Gray Thermoplastic, 125oC (257oF) (UL RTI) Flammability, UL 94 V-0 Mounting: DIN or panel mount, clip must be inserted for DIN rail mount
+ Refer to www.marathonsp.com/ PDFs/ 1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

UL Listed Enclosed Power Distribution Blocks

Standards UL Listed File No. QPQS.E309401 (UL 1953) CSA Certified File No. LR19766 (CSA C22-2 No. 158) (Component IEC 60947-7-1) IEC 60529, IP-20 RoHS Compliant Accessories (consult Cust. Service) White Markers to Identify Circuits DIN Rail (MN35-2) End Bracket for DIN Rail (MSK35)

Shown left to right: EPBAD42, EPBCD45

LINE SIDE Catalog # EPBAD42 EPBAP42 EPBCD42 EPBCP42 EPBAD45 EPBAP45 EPBCD45 EPBCP45 200 200 200 200 Amps Wire Range AWG/kcmil 3/0 - #14 AWG 70 - 2.5 mm2 Openings Per Pole Connector Configuration Wire Range AWG/kcmil 3/0 - #14 AWG 70 - 2.5 mm2

LOAD SIDE Openings Per Pole Connector Configuration

SCCR, RMS SYM Amps 600 Volt Max

100,000

3/0 - #14 AWG 70 - 2.5 mm2 3/0 - #14 AWG 70 - 2.5 mm2

3/0 - #14 AWG 70 - 2.5 mm2 #2 - #14 AWG 35 - 2.5 mm2

100,000

65,000 / 100,000

3/0 - #14 AWG 70 - 2.5 mm2

#2 - #14 AWG 35 - 2.5 mm2

65,000 / 100,000
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Ordering Code:

EPB

42
42 - (1) 3/0 to (1) 3/0 45 - (1) 3/0 to (4) #2
2.71 68.9

D - Mount on Connector Material: A - Aluminum rated copper 35 mm DIN rail P - Flat panel or aluminum wire C - Copper CU wire only

SLOT .50 X .25, [12.7 X 6.4] FOR USE WITH 1/4" (6mm) MTG SCREW 6mm HEX DRIVE

STACK-UP DIMENSIONS (If Dovetail is used for Mulit-Line)


3.33 84.5 2.22 56.4

Note: 1) 2) 3) The ampacities are based on Table 310-16 of the NEC. The connectors were tested and approved per UL 486 A/B. For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

DOVETAIL FEATURES ON SIDES OF BLOCK FOR MULTI-LINE STACK-UP


3.61 91.7 3.00 76.2

TYP. FOR SNAP-IN MARKER CARDS 4mm HEX DRIVE

SCCR RATINGS & ENGLISH & METRIC WIRE RANGES W/TORQUE PRINTED ON SIDES OF BLOCK.

.09 2.3

1.11 28.2

1.11 28.2 2.22 56.4

Datasheets available at marathonsp.com

41

Enclosed Power Distribution Blocks


Specifications:
Multiple Wire Ratings Electrical Copper Stranded Wire Only 600 Volts AC/DC+ Load Side Taps Only (IEC - 690 Volts AC/DC) #2 opening: 2/0 opening: Up to 510 Amps (2) #6 AWG (2) #4 AWG Wire Range 2/0 to 400 kcmil (2) #8 AWG (2) #6 AWG Flexible Stranded Wire Compliant (2 to 4) #10 AWG (2) #8 AWG Mechanical (2 to 4) #12 AWG (2) #10 AWG Base, Gray Thermoplastic, (2 to 4) #14 AWG (2) #12 AWG 125oC (UL RTI) (2) #14 AWG Flammability, UL 94 V-0 Connector Wire Hole Size Mounting: DIN or panel mount Conductor Diameter of Standards opening: opening: UL Recognized File No. #2 - #14 AWG .38 XCFR2.E62806 (UL 1059) 2/0 - #14 AWG .50 CSA Certified File No. LR19766 250 kcmil - #6 AWG .72 (CSA C22.2 No. 158) 400 kcmil - #6 AWG .94 (IEC 60947-7-1) IEC 60529, IP-20 RoHS Compliant
LINE SIDE Catalog # EPBXD71 510 EPBXP71 EPBXD74 EPBXP74 Ordering Code: Amps Wire Range AWG/kcmil 250 kcmil - #6 AWG 120 - 16 mm
2

Enclosed Power Distribution Blocks

Shown left to right: EPBAD74, EPBAD71

Accessories (consult Cust. Service) White Markers to Identify Circuits Black Thermoplastic Safety Plugs Feeder Spacing Adapter Plate (see p 36)
+ Refer to www.marathonsp.com/ PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

LOAD SIDE Connector Config. Wire Range AWG/kcmil 250 kcmil - #6 AWG 120 - 16 mm2 Openings Per Pole

Openings Per Pole

SCCR, RMS Connector SYM Amps Config. 600 Volt Max 10,000

50,000 100,000

400 kcmil - #6 AWG 335 185 - 16 mm2 2/0 - #14 AWG 70 -2.5 mm2

1 1

#2 - #14 35 - 2.5mm2

10,000 100,000

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

EPB

D
D - Mount on 35 mm DIN rail or flat panel P - Flat panel

71
71 - (2) 250 kcmil to (2) 250 kcmil 74 - (1) 400 kcmil to (1) 2/0 to (8) #2

Connector Material: A - Aluminum rated copper or aluminum wire C - Copper rated copper wire only

STACK UP DIMENSIONS (IF DOVETAIL IS USED FOR MULTI-LINE PB) SLOT .52 X .27 [13.21 X 6.86] 6.66 169.10 4.44 112.73

Note: 1) 2) The ampacities are based on Table 310-16 of the NEC. For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

3.29 83.47 3.14 79.79

4.73 [114.54] 3.75 [95.25] 4.39 [111.44]

TYP. FOR SNAP-IN MARKER CARDS

1.11 [28.18] 2.27 57.58

2.22 56.36 4.44 112.73

42

Datasheets available at marathonsp.com

Power Terminal Blocks


General Information:
Barrier Style Power Terminal Blocks are available in eight sizes. They are identified by the first three digits of the catalog number. The 140, 142, 143, 144 and 145 series are manufactured with general purpose phenolic rated at 150oC. The 141, 132 and 133 series are manufactured with high impact thermoplastic rated at 125oC.

Power Blocks

Connector Wire Hole Size:


Conductor Opening Diameter of Opening English Inch Metric Metric #10 AWG .158 4.0 6 #4 AWG .250 6.4 25 #2 AWG .312* 7.9 35 1/0 .406 10.3 50 2/0 .438* 11.1 70 3/0 .532 13.5 95 250 kcmil .630* 16.0 120 350 kcmil .718 18.2 185 400 kcmil .769* 500 kcmil .875 22.2 240 600 kcmil .938 23.8 300 750 kcmil 1.125 1000 kcmil 1.250 * Enclosed blocks have larger openings (see page 42)

Ratings and Standards:


The voltage ratings of terminal blocks are based upon the minimum spacing between electrically conductive parts line to line through air and over surface and line to ground through air and over surface. Class A Service equipment including deadfront switchboards, panel boards, service entrance devices. Class B Commercial appliances including business equipment, electronic data processing equipment and the like. Class C General industrial and machine tool controls which can be further defined as equipment falling under UL 508. Ratings based on UL 1059 may be higher in some cases depending on application.

Spacing Requirements (in inches):


Voltage Class A 51-150 151-300 301-600 51-150 151-300 301-600 51-150 151-300 301-600 Thru Air .500 .750 1.000 .063 .094 .375 .125 .250 .375 Over Surface .750 1.250 2.000 .063 .094 .500 .250 .375 .500

Class B

Class C

Applications:
Designed for use with solar, wind, alternate energy, transportation, heating, air conditioning and refrigeration, elevator systems, material handling equipment, control panels, motor control, switchgear and any area where power needs to be distributed to more than one load.

43

Power Distribution Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Power Blocks

1423570

1414400

Replace X with # of poles (0 = Adder)


LINE SIDE LOAD SIDE Wire Range AWG/kcmil #10 - #16 AWG Openings Connector Per Pole Configuration 2 Openings Connector Per Pole Configuration 1

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 141X403 1/2/3/4 60 Plastic AL Wire Range AWG/kcmil #2 - #14 AWG

141X400

1/2/3/4

115

Plastic

AL

#2 - #14 AWG

#10 - #18 AWG

132X570

CH

0/1/2/3

175

Plastic

AL

2/0 - #14 AWG

#4 - #14 AWG

142X570

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

#4 - #14 AWG

132X580

CH

0/1/2/3

175

Plastic

AL

2/0 - #14 AWG

#4 - #14 AWG

140X402

2/3

175

Phenolic

AL

2/0 - #14 AWG

#4 - #14 AWG

140X401

2/3

175

Phenolic

AL

2/0 - #14 AWG

#4 - #14 AWG

132X970

CH

0/1/2/3

175

Plastic

CU

2/0 - #14 AWG

#4 - #14 AWG

142X970

1/2/3

175

Phenolic

CU

2/0 - #14 AWG

#4 - #14 AWG

140X404

2/3

310

Phenolic

AL

350 kcmil - #6 AWG

#4 - #14 AWG

133X554

CH

1/2/3

310

Plastic

AL

350 kcmil - #6 AWG

2/0 - #14 AWG

140X410

2/3

310

Phenolic

AL

350 kcmil - #6 AWG

2/0 - #14 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers

See pages 55-57 for dimensional information

44

Datasheets available at marathonsp.com

Power Distribution Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Power Blocks

1443560

1433553

Replace X with # of poles


LINE SIDE LOAD SIDE Wire Range AWG/kcmil 2/0 - #14 AWG Openings Connector Per Pole Configuration 2 Openings Connector Per Pole Configuration 1

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 143X554 1/2/3 310 Phenolic AL Wire Range AWG/kcmil

350 kcmil - #6 AWG

144X401

1/2/3

335

Phenolic

AL

400 kcmil - #6 AWG

#2 - #14 AWG

143X552

1/2/3

335

Phenolic

AL

400 kcmil - #6 AWG

#2 - #14 AWG

143X553

1/2/3

335

Phenolic

AL

400 kcmil - #6 AWG

#2 - #14 AWG

144X560

1/2/3

335

Phenolic

AL

400 kcmil - #6 AWG

#2 - #14 AWG

133X552

CH

1/2/3

335

Plastic

AL

400 kcmil - #6 AWG

#2 - #14 AWG

133X553

CH

1/2/3

335

Plastic

AL

400 kcmil - #4 AWG

#2 - #14 AWG

143X555

1/2/3

350

Phenolic

AL

2/0 - #14 AWG

#4 - #14 AWG

133X555

CH

1/2/3

350

Plastic

AL

2/0 - #14 AWG

#4 - #14 AWG

143X955

1/2/3

350

Phenolic

CU

2/0 - #14 AWG

#4 - #14 AWG

133X955

CH

1/2/3

350

Plastic

CU

2/0 - #14 AWG

#4 - #14 AWG

143X953

1/2/3

380

Phenolic

CU

500 kcmil - #4 AWG

#2 - #14 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers

See pages 55-57 for dimensional information

Datasheets available at marathonsp.com

45

Power Distribution Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts
1333588 CH

(cont.)

Power Blocks

1333595 CH

Replace X with # of poles


LINE SIDE LOAD SIDE Wire Range AWG/kcmil #2 - #14 AWG Openings Connector Per Pole Configuration 6 Openings Connector Per Pole Configuration 1

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 133X953 CH 1/2/3 380 Plastic CU Wire Range AWG/kcmil

500 kcmil - #4 AWG

144X551

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

#2 - #14 AWG

145X579

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

2/0 - #14 AWG


#2 - #14 AWG 350 kcmil - #6 AWG #2 - #14 AWG 350 kcmil - #6 AWG

6 3 1 3 1 8

133X587

CH

1/2/3

380

Plastic

AL

500 kcmil - #4 AWG

143X587

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

145X594

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

#2 - #14 AWG

145X552

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

#2 - #14 AWG #2 - #14 AWG 1/0 - #14 AWG 4 - #14 AWG

12 6 3 12

133X588

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

133X595

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

133X585

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

2 - #14 AWG

133X575

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

2/0 - #14 AWG

133X565

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

250 kcmil - #6 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering - See page 58 for available covers

See pages 55-57 for dimensional information

46

Datasheets available at marathonsp.com

Power Distribution Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766

(cont.)

Power Blocks

1333596 CH

1333598 CH

Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Replace X with # of poles


LINE SIDE LOAD SIDE Wire Range AWG/kcmil #4 - #14 AWG Openings Connector Per Pole Configuration 12 Connector Openings Per Pole Configuration 2

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 133X596 CH 1/2/3 510 Plastic AL Wire Range AWG/kcmil

250 kcmil - 1/0 AWG

133X597

CH

1/2/3

510

Plastic

AL

250 kcmil - 1/0 AWG

#2 - #14 AWG

133X598

CH

1/2/3

510

Plastic

AL

250 kcmil - 1/0 AWG 500 kcmil - #4 AWG 350 kcmil - #4 AWG 500 kcmil - #4 AWG

2 1 1 2

2/0 - #14 AWG

145X587

1/2/3

690

Phenolic

AL

2/0 - #14 AWG

145X592

1/2/3

760

Phenolic

AL

#4 - #14 AWG

12

145X586

1/2/3

760

Phenolic

AL

500 kcmil - #6 AWG

2/0 - #14 AWG

145X992

1/2/3

760

Phenolic

CU

500 kcmil - #4 AWG

#2 - #14 AWG

12

145X986

1/2/3

760

Phenolic

CU

500 kcmil - #4 AWG

2/0 - #14 AWG

145X408

1/2/3

760

Phenolic

AL

500 kcmil - #6 AWG

#2 - #14 AWG 3/0 - #6 AWG #4 - #14 AWG 2/0 - #14 AWG

12 4 4 18

145X411

1/2/3

840

Phenolic

AL

600 kcmil - #2 AWG

1453401*

2280 Phenolic

AL

500 kcmil - #4 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering - See page 58 for available covers *Special one-pole block. Apply Power Block Dimensions for 145 Series block on page 57 (3 pole).

See pages 55-57 for dimensional information

Datasheets available at marathonsp.com

47

Power Splicer Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Power Blocks

1323972 CH

1323572 CH

Replace X with # of poles (0 = Adder)


MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 141X300 1/2/3/4 115 Plastic AL Wire Range AWG/kcmil #2 - #14 AWG LINE SIDE Openings Connector Per Pole Configuration 1 Wire Range AWG/kcmil #2 - #14 AWG LOAD SIDE Openings Connector Per Pole Configuration 1

142X552

1/2/3

115

Phenolic

AL

#2 - #14 AWG

#2 - #14 AWG

132X572

CH

0/1/2/3

175

Plastic

AL

2/0 - #14 AWG

2/0 - #14 AWG

142X572

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

2/0 - #14 AWG

132X972

CH

0/1/2/3

175

Plastic

CU

2/0 - #14 AWG

2/0 - #14 AWG

142X121

1/2/3

175

Phenolic

CU

1/0 - #14 AWG

1/0 - #14 AWG

143X124

1/2/3

255

Phenolic

CU

250 kcmil - #6 AWG

250 kcmil - #6 AWG

140X801

2/3

255

Phenolic

CU

250 kcmil - #6 AWG

250 kcmil - #6 AWG

143X123

1/2/3

255

Phenolic

AL

250 kcmil - #6 AWG

250 kcmil - #6 AWG

140X303

2/3

310

Phenolic

AL

350 kcmil - #6 AWG

350 kcmil - #6 AWG

143X126

1/2/3

310

Phenolic

AL

350 kcmil - #6 AWG

350 kcmil - #6 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers

See pages 55-57 for dimensional information

48

Datasheets available at marathonsp.com

Power Splicer Blocks (cont.)


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire CU Connector, High Conductive Copper, Tin Plated, Rated for Copper Wire Only Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Power Blocks

1333305

1453129

Replace X with # of poles


MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 133X126 CH 1/2/3 310 Plastic AL Wire Range AWG/kcmil 350 kcmil - #6 AWG LINE SIDE Openings Connector Per Pole Configuration 1 Wire Range AWG/kcmil 350 kcmil - #6 AWG LOAD SIDE Openings Connector Per Pole Configuration 1

133X305

CH

1/2/3

350

Plastic

AL

2/0 - #14 AWG

2/0 - #14 AWG

143X306

1/2/3

350

Phenolic

AL

2/0 - #14 AWG

2/0 - #14 AWG

144X557

1/2/3

420

Phenolic

AL

600 kcmil - #4 AWG

600 kcmil - #4 AWG

133X360

CH

1/2/3

420

Plastic

AL

600 kcmil - #2 AWG

600 kcmil - #2 AWG

133X320

CH

1/2/3

510

Plastic

AL

250 kcmil - 1/0 AWG

250 kcmil - 1/0 AWG

145X129

1/2/3

620

Phenolic

AL

350 kcmil - #4 AWG

350 kcmil - #4 AWG

145X301

1/2/3

760

Phenolic

AL

500 kcmil - #4 AWG

500 kcmil - #4 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering - See page 58 for available covers

See pages 55-57 for dimensional information

Datasheets available at marathonsp.com

49

Power Stud Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:

+

Power Blocks

Connector, High Conductive Copper, Tin Plated Stud, Brass, Tin Plated, Metric (M) Studs, Steel Rated for multiple wire lugs, where applicable Suitable for Compression Wire Lugs Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com

1423122

1423123

Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Replace X with # of poles (0 = Adder)


LINE SIDE LOAD SIDE Wire Range AWG/kcmil 1/4-20 x 9/16 Openings Per Pole 1 Connector Configuration Openings Connector Per Pole Configuration 1

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 132X122 CH 0/1/2/3 200 Plastic CU Wire Range AWG/kcmil 1/4-20 x 9/16

132X422

CH

0/1/2/3

200

Plastic

CU

M6 x 15

M6 x 15

142X123

1/2/3

200

Phenolic

CU

1/4-20 Screw

1/4-20 Screw

142X122

1/2/3

200

Phenolic

CU

1/4-20 x 9/16

1/4-20 x 9/16

143X563

1/2/3

230

Phenolic

CU

3/8-16 x 1 3/16

3/8-16 x 1 3/16

143X561

1/2/3

230

Phenolic

CU

3/8-16 x 1 3/16

1/4-20 x 1 3/16

144X553

1/2/3

230

Phenolic

CU

3/8-16 x 1 7/16

3/8-16 x 1 7/16

144X122

1/2/3

260

Phenolic

CU

3/8-16 x 1 7/16

1/4-20 x 1 9/16

2
0.75

133X564

CH

1/2/3

310

Plastic

CU

M10 X 30

M10 X 30

133X563

CH

1/2/3

310

Plastic

CU

3/8-16 x 1 3/16

3/8-16 x 1 3/16

145X573

1/2/3

360

Phenolic

CU

3/8-16 x 1 7/16

3/8-16 x 1 7/16

2
1.122

145X583

1/2/3

360

Phenolic

CU

3/8-16 x 1 7/16

1/4-20 X 1 7/16

2
1.125

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers

See pages 55-57 for dimensional information

50

Datasheets available at marathonsp.com

Power Stud Blocks (cont.)


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Copper, Tin Plated Stud, Brass, Tin Plated, Metric (M) Studs, Steel Rated for multiple wire lugs, where applicable Suitable for Compression Wire Lugs Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Power Blocks

1453606

1443614

Replace X with # of poles (0 = Adder)


LINE SIDE LOAD SIDE Wire Range AWG/kcmil 1/2-13 x 1 7/16 Openings Per Pole 1 Connector Configuration Openings Connector Per Pole Configuration 1

MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 145X606 1/2/3 410 Phenolic CU Wire Range AWG/kcmil 1/2-13 x 1 7/16

133X611

CH

1/2/3

410

Plastic

CU

1/2-13 x 1.38

1
1.375

1/2-13 x 1.38

145X613

1/2/3

475

Phenolic

CU

3/8-10 x 1 7/16

3/8-10 x 1 7/16

144X614

1/2/3

840

Phenolic

CU

3/8-16 x 1

3/8-16 x 1

See pages 55-57 for dimensional information See page 58 for available covers

Datasheets available at marathonsp.com

51

Miscellaneous Power Splicer Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Power Blocks
Connector, High Conductive Aluminum, Tin Plated Rated for Copper and Aluminum Wire Stud, Brass, Tin Plated Quick Connect, Brass, Tin Plated 10-32 Screw, Brass, Nickel Plated Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on www.marathonsp.com
Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts
1413202 1413205

Replace X with # of poles


LOAD SIDE Load Connection 10-32 Screw 10-32 Tapped Hole .25 x .032 QC #10-32 Hole & (2) QC #2 - #14 AWG & (1) QC M6 Hole Openings Connector Per Pole Configuration 1 Openings Connector Per Pole Configuration 1

MATERIAL Catalog # 141X200 Poles (X) 1/2/3/4 Amps 115 Insulator Conn. Plastic AL Wire Range AWG/kcmil #2 - #14 AWG

LINE SIDE

141X201

1/2/3/4

115

Plastic

AL

#2 - #14 AWG

141X202

1/2/3/4

115

Plastic

AL

#2 - #14 AWG

141X205

1/2/3/4

115

Plastic

AL

#2 - #14 AWG

141X301

1/2/3/4

115

Plastic

AL

#2 - #14 AWG

142X411

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

142X553

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

1/4-20 Tapped Hole

See page 58 for available covers See pages 55-57 for dimensional information

52

Datasheets available at marathonsp.com

Power Splicer/Stud Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire Stud, Brass, Tin Plated, Metric (M) Studs, Steel intended for wires terminated with crimp lugs Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire

Power Blocks

Multiple wire rating - refer to datasheets for details


1433559 1453599 UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 (does not apply to 133X559, 133X558, and 143X559) Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, + Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts please refer to datasheets on www.marathonsp.com

Replace X with # of poles (0 = Adder)


MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 141X203 1/2/3/4 115 Plastic AL Wire Range AWG/kcmil #2 - #14 AWG LINE SIDE Openings Connector Per Pole Configuration 1 Wire Range AWG/kcmil 10-32 X .60 Stud LOAD SIDE Openings Per Pole 1 Connector Configuration

132X574

CH

0/1/2/3

175

Plastic

AL

2/0 - #14 AWG

1/4-20 x 1/2

132X474

CH

0/1/2/3

175

Plastic

AL

2/0 - #14 AWG

M6 x 13

142X574

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

1/4-20 x 1/2

143X590

1/2/3

175

Phenolic

AL

2/0 - #14 AWG

1/4-20 x 1 3/8

143X559

1/2/3

310

Phenolic

AL

350 kcmil - #6 AWG

3/8-16 x 11/8 Stud

133X559

CH

1/2/3

310

Plastic

AL

350 kcmil - #6 AWG

3/8-16 x 1 1/4

133X558

CH

1/2/3

310

Plastic

AL

350 kcmil - #6 AWG

M10 x 30

144X569

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

1/4-20 x 1 1/16

2
0.75

144X575

1/2/3

380

Phenolic

AL

500 kcmil - #4 AWG

3/8 - 16 x 1 5/16

145X599

1/2/3

760

Phenolic

AL

500 kcmil - #4 AWG

3/8 - 16 x 1 5/16

2
1.16

145X610

1/2/3

760

Phenolic

AL

500 kcmil - #4 AWG

1/2-13 x 1 5/16

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering (not available on Adder blocks) - See page 58 for available covers

See pages 55-57 for dimensional information

Datasheets available at marathonsp.com

53

Power Stud to Distribution Blocks


600 Volts AC/DC Up to 1000 Volts AC/DC ( )+
Specifications:
Connector, High Conductive Aluminum, Tin Plated, Rated for Copper and Aluminum Wire Stud, Brass, Tin Plated, Metric (M) Studs, Steel intended for wires terminated with crimp lugs Amp Rating Based on NEC Table 310-16 Using 75oC Copper Wire Rated for multiple wire lugs, where applicable Multiple wire rating - refer to datasheets for details UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 Flexible Stranded Wire Compliant RoHS Compliant For detailed SCCR information with fuses and circuit breakers, please refer to datasheets on

Power Blocks

1333270

1333273 CH

Refer to www.marathonsp.com/PDFs/1000VCERating.pdf for details on availability of CE voltage ratings greater than 600 Volts

Replace X with # of poles


MATERIAL Hinge Poles Catalog # Cover (X) Amps Insulator Conn. 133X272 CH 1/2/3 510 Plastic AL Threaded Stud Size 3/8-16 x 1 3/16 LINE SIDE Openings Connector Per Pole Configuration 1 Wire Range AWG/kcmil #4 - #14 AWG LOAD SIDE Openings Connector Per Pole Configuration 12

133X273

CH

1/2/3

510

Plastic

AL

M10 x 30

#4 - #14 AWG

12

133X280

CH

1/2/3

510

Plastic

AL

3/8-16 x 1 3/16

#2 - #14 AWG

133X281

CH

1/2/3

510

Plastic

AL

M10 x 30

#2 - #14 AWG

133X270

CH

1/2/3

510

Plastic

AL

3/8-16 x 1 3/16

2/0 - #14 AWG

133X271

CH

1/2/3

510

Plastic

AL

M10 x 30

2/0 - #14 AWG

145X282*

1/2/3

760

Phenolic

AL

3/8-16 x 1.00

2
1.16

2/0 - #14 AWG

CH = Block is also available with hinge cover attached - include CH at end of part number when ordering - See page 58 for available covers *cURus only

See pages 55-57 for dimensional information

54

Datasheets available at marathonsp.com

Power Terminal Block Dimensions


132 SERIES
.89 22.5 1.00 25.5 1.82 46.3 2.55 64.8 2.42 61.5 .20 5

Power Blocks

2.25 57.2

3.00 76.2

SLOT .49 X .22 THRU [12.3 X 5.5] TYP.

Adder
132 CH SERIES
1.00 25.5

1 Pole

.81 20.7 TYP.

1.63 41.3

.85 21.6

2 Pole

3 Pole
2.55 64.8 2.57 65.2

1.82 46.3

2.25 57.2 (MTG. SLOTS)

3.00 76.2

.81 20.7 (MTG SLOTS) TYP.

1.63 41.3 (MTG SLOTS)

SLOT .49 X .22 THRU [12.3 X 5.5] TYP.

1 Pole
133 SERIES
1.96 49.7 .31 7.9

2 Pole
3.66 92.9

3 Pole
5.36 136.1

SLOT .21 X .71 THRU CB .44 X .94 X .29 DP TYP.

4.00 101.6

3.38 85.7

.97 24.6 TYP.

1.70 43.2 TYP.

3.40 86.4

3.33 84.6

1 Pole
133 CH SERIES
1.96 49.7 .31 7.9

2 Pole

3 Pole
SLOT .21 X .71 THRU CB .44 X .94 X .29 DP TYP.

3.66 92.9

5.36 136.1

4.00 101.6

3.38 85.7 (MTG. SLOTS)

.97 24.6 TYP.

1.70 43.2 (MTG SLOTS) TYP.

3.40 86.4 (MTG SLOTS)

3.49 88.6

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

1 Pole

2 Pole 55

3 Pole

Datasheets available at marathonsp.com

Power Terminal Block Dimensions


140 SERIES
4.13 104.8 5.38 136.5 2.06 52.3

Power Blocks

1.00 25.4

2.90 73.7

3.38 85.7 3.52 89.3

4.63 117.5 4.77 121

(2)SLOTS .27 X .38 [6.7 X 9.5] (4)SLOTS .22 X .38 [5.5 X 9.5]

2 Pole

3 Pole

141 SERIES

.20 THRU TYP. 5.1

1.27 32.2

1.91 48.5

.38 9.7 TYP.

.18 4.6

1.93 49.1

2.29 58.1

.84 21.2

1.46 37

2.10 53.2

2.74 69.5

1.53 38.7

1 Pole

2 Pole

3 Pole

4 Pole

142 SERIES
1.13 28.6 1.94 49.2 2.75 69.9 1.78 45.2

2.25 57.2

2.88 73

.81 20.6

.56 14.3

1.62 41.2

.23 5.7

1 Pole

2 Pole

3 Pole

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

56

Datasheets available at marathonsp.com

Power Terminal Block Dimensions


143 SERIES
1.94 49.2 3.47 88.1 5.00 127 2.61 66.2

3.38 85.9

Power Blocks

4.00 101.7

.97 24.6 TYP.

1.53 38.9 TYP.

3.06 77.8

.203 [5.2] THRU CB .406 [10.3] TYP.

.23 5.8

1 Pole

2 Pole

3 Pole

144 SERIES
2.28 57.9 4.16 105.7 6.03 153.2 2.91 73.9

4.13 104.8 TYP.

4.75 120.6

1.14 29 TYP.

1.88 47.6 TYP.

3.75 95.3

.203 [5.2] THRU CB .406 [10.3] TYP.

.33 8.4

1 Pole

2 Pole

3 Pole

145 SERIES

3.17 80.5

5.88 149.2

8.54 216.9

3.13 79.4

4.75 120.7 TYP.

5.50 139.7

1.59 40.3 TYP.

2.69 68.3 TYP.

5.38 136.5

.265 [6.7] THRU CB .50 [10.3] TYP.

.31 7.7

1 Pole

2 Pole

3 Pole

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

57

Power Block Covers


Specifications:
140/141/142/143/144/145 Series (Figures 1 & 2) Power Blocks

B A

Material UL Recognized, QMFZ2, 125oC, .06 Clear Protective Plastic Thread Cutting Screws Furnished Per Cover RoHS Compliant

132/133 Series (Figure 3)


Snap on, Hinged Cover, Black Thermoplastic UL Recognized, QMFZ2, 125oC RoHS Compliant

FIGURE 1

135 Series (Figure 4)


Snap on, Hinged Cover, Black Thermoplastic UL Recognized, QMFZ2, 125oC RoHS Compliant

A B

Dimensions (inches):
Catalog # CC1402 CC1403 CC1411 CC1412 CC1413 CC1414 CC1421 CC1422 CC1423 CC1431 CC1432 CC1433 CC1441 CC1442 CC1443 CC1451 CC1452 CC1453 CH1321 CH1322 CH1323 CH1331 CH1332 CH1333 CH1351 (one pole only) A 2.75 4.00 0.77 1.42 2.05 2.68 1.06 1.87 2.68 1.78 3.31 4.84 2.12 4.00 5.87 2.87 5.56 8.28 0.88 1.69 2.50 1.93 3.61 5.30 3.35 B 2.25 Figure # 1

FIGURE 2
A

2.40

2.75

3.38

4.00

4.50

FIGURE 3 (Hinged Cover)

2.87

3
B

3.89

5.65

FIGURE 4 (Hinged Cover)

58

Datasheets available at marathonsp.com

Grounding Lugs
Specifications:
Connector, High Conductive Aluminum, Tin Plated Screw head is green ink Flexible Stranded Wire Compliant UL Recognized File No. ZMVV2.E43665 CSA Certified File No. 63510-25 RoHS Compliant
Catalog # (Part #) GL02 (9807052) Wire Range AWG/kcmil #2 - #3 #4 - #6 #8 #10 - #14 Torque lb in 50 45 40 35

GL02:
5/16-24 SET SCREW

.266 [6.75]

Power Blocks

.25 [6.4] 1.15 [29.2] .90 [22.9]


C
SA

.31 [7.9] .23 [5.9]


2-14 9807052 CUAL

.16 [4.0]

.59 [15.1] 1.40 [35.6]

Slotted or hex head screw available


.25 [6.3] .50 [12.7]

GL20:

3/16 HEX SOCKET .406 [10.32]

Catalog # (Part #) GL20 (9718102)

Wire Range AWG/kcmil 2/0 - #6 #8 #10 - #14

Torque lb in 120 40 35

.44 [11.1] .44 [11.1] 1.31 [33.3]

.32 [8.2]
9718102

1.00 [25.4]
M

C
SA

.75 [19.1]

.25 [6.4]

2/0-14 CUAL

.31 [7.7] .61 [15.5]

1.63 [41.3]

GL35:

5/16 HEX SOCKET

.531 [13.49]

Catalog # (Part #) GL35 (9819830)

Wire Range AWG/kcmil 350 kcmil - #6

Torque lb in 375

.56 [14.3] .50 [12.7] .72 [18.3] 1.69 [42.9] 1.13 [28.6]

SA C 9819830

.54 [13.7]

1.25 [31.8]
CUAL 350MCM-6

.25 [6.4]

.56 [14.3] 1.13 [28.6]

2.25 [57.2]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

59

Studded Power Feed Thru Terminal Blocks


ST722 Series
The Studded Power Feed Thru Terminal Blocks were designed for applications where power feed thru is necessary using standard double hole lugs with .625 spacing.

Studded Power Feed Thru Terminal Blocks

These terminal blocks are available in three mounting options (end mount, back mount, and slide-in mount). They are also offered in various line lengths and with various hardware options (See Hardware Descriptions Below). These terminal blocks lower cost by eliminating multiple components and assembly time. The terminal blocks are manufactured from top quality insulator and conductor materials. They are designed with a robust one-piece insulator base using a one-piece conductor permanently assembled together. Covers are molded using a one-piece design and are available as an option for all three series of these blocks.

Series ST722

Mounting B

Stud (Thread Size) 2 5 0

Poles 2

Hardware

B Back Mount S Slide Mount E End Mount

19 - #10-32 Stud 25 - 1/4 - 20 Stud M5 - M5 Stud M6 - M6 Stud

(Back Mount) 02 06 (Slide Mount) 01 04 (End Mount) 01 06

(blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk

Optional Cover Available:


Cover is offered in 1 6 poles One cover accommodates all series Base, Thermoplastic Flammability UL 94 V-0
"A"

Catalog Number C72201 C72202 C72203 C72204 C72205 C72206

Number of Poles 1 2 3 4 5 6

Dimensions A Inches 0.91 1.64 2.37 3.10 3.83 4.56 Metric (23.11) (41.66) (60.20) (78.74) (97.28) (115.82)

38.74 1.53

19.76 0.78

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

60

Studded Power Feed Thru Terminal Blocks


ST722B Series (back mount)
Specifications: Electrical:
300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625 Centers wires #2 and larger may require narrow lugs

Studded Power Feed Thru Terminal Blocks

General/Mechanical:

Base, Thermoplastic, 125oC (UL RTI) Studs, Brass, Nickel Plated 2 6 Poles .73 Centers Application Torque: 35 lbf-in for #10 - 32 and M5, 50 lbf-in for 1/4 - 20 and M6 UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

ST722B2502

LENGTH 2-LINE 3-LINE 4-LINE 5-LINE 6-LINE

Catalog Number ST722BXX02 ST722BXX03 ST722BXX04 ST722BXX05 ST722BXX06


Replace XX with thread size: 19 - #10-32 Stud 25 - 1/4 - 20 Stud M5 - M5 Stud M6 - M6 Stud

Number of Poles 2 3 4 5 6

Dimensions A Inches 1.55 2.28 3.01 3.74 4.47 Metric (39.37) (57.91) (75.45) (95.00) (113.54)
See page 60 for available covers

"P" ENG. MET. 1.35 34.3 2.08 52.8 2.81 71.4 3.54 89.9 4.27 108.5

"P"

1.20 (31)

ST722 PANEL CUT-OUT

Hardware Options: (blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk

"A" .64 16.3 .73 18.5


BLIND HOLE FOR #6 THREAD CUTTING SCREW, 1.00 (4) SCREWS PROVIDED 25.4 PER ASSEMBLY FOR MULTI-POLE BLOCKS (>2), TWO ADDITIONAL MTG HOLES BETWEEN EACH ADDTIONAL POLE.

THD. X .43 TYP. BOTH ENDS

.63 15.9

1.50 38.1

1.05 26.8

1.90 48.3

.73 18.5

.60 15.3

.60 15.3

((4) #6 THREAD CUTTING SCREWS PROVIDED)

.54 13.7

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

61

Studded Power Feed Thru Terminal Blocks


ST722S Series (slide-in mount)
Specifications:
Studded Power Feed Thru Terminal Blocks

Electrical:

300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625 Centers wires #2 and larger may require narrow lugs

General/Mechanical:

Base, Thermoplastic, 125oC (UL RTI) Studs, Brass, Nickel Plated 1 - 4 Poles .73 Centers Application Torque: 35 lbf-in for #10 - 32 and M5, 50 lbf-in for 1/4 - 20 and M6 UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

ST722S2502

Catalog Number ST722SXX01 ST722SXX02 ST722SXX03 ST722SXX04


Replace XX with thread size: 19 - #10-32 Stud 25 - 1/4 - 20 Stud M5 - M5 Stud M6 - M6 Stud

Number of Poles 1 2 3 4
Hardware Options:

Dimensions A Inches 0.82 1.55 2.28 3.01 Metric (20.83) (39.37) (57.91) (76.45)
See page 60 for available covers

(blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk

"A" .64 16.2 THD. X .43 TYP. BOTH ENDS

.63 15.9

1.50 38.1

1.25 31.8

1.00 25.4

1.90 48.3

.73 18.5
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.062 1.57 .54 13.7

62

Datasheets available at marathonsp.com

Studded Power Feed Thru Terminal Blocks


ST722E Series (end mount)
Specifications:
Studded Power Feed Thru Terminal Blocks

Electrical:

300 Volts AC/DC (UL 1059 Class B and C) 175 Amps Wire Range 2/0 - #8 Accommodates Two Hole Compression Lugs on .625 Centers wires #2 and larger may require narrow lugs

General/Mechanical:

Base, Thermoplastic, 125oC (UL RTI) Studs, Brass, Nickel Plated 1 - 6 Poles .73 Centers Application Torque: 35 lbf-in for #10 - 32 and M5, 50 lbf-in for 1/4 - 20 and M6 UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

ST722E2503

Catalog Number ST722EXX01 ST722EXX02 ST722EXX03 ST722EXX04 ST722EXX05 ST722EXX06

Number of Poles 1 2 3 4 5 6

Dimensions A Inches 1.32 2.05 2.78 3.51 4.24 4.97 Metric (33.53) (52.07) (70.61) (89.15) (107.70) (126.24)

Dimensions B Inches 1.77 2.50 3.23 3.96 4.69 5.42 Metric (44.96) (63.50) (82.40) (100.58) (119.13) (137.67)
See page 60 for available covers
1.29 .63 .33

LENGTH 1-LINE 2-LINE 3-LINE 4-LINE 5-LINE 6-LINE

"P1" 1.32 2.05 2.78 3.51 4.24 4.97


"P1" "P2"

"P2" .66 1.39 2.12 2.85 3.58 4.31

.33 TYP.

ST722 PANEL CUT-OUT

.23 TYP.

Replace XX with thread size: 19 - #10-32 Stud 25 - 1/4 - 20 Stud M5 - M5 Stud M6 - M6 Stud

Hardware Options: (blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk

"B" "A" .64 16.3

THD. X .43 TYP. BOTH ENDS

1.00 25.4 .63 15.9 1.50 38.1

1.90 48.3

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.23 5.8

.73 18.5

.54 13.7

Datasheets available at marathonsp.com

63

Studded Power Feed Thru Terminal Blocks


ST715S1902
Specifications:
Studded Power Feed Thru Terminal Blocks

Electrical:

300 Volts AC/DC (UL 1059 Class B and C) 80 Amps Wire Range #6 - #14 Accommodates Two Hole Compression Lugs on .625 Centers

General/Mechanical:

Base, Thermoplastic, 125oC (UL RTI) Studs, Brass, Nickel Plated 2 Poles .56 Centers Application Torque: 35 lbf-in UL Recognized File No. XCFR2.E62806 cURus Certified File No. XCFR8.E62806 RoHS Compliant

ST715S902

Hardware Options: (blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk
.12 2.9 .096 X .19 DP [2.4 X 4.8] FOR #4 SCREW 1.25 31.8 .79 20.1 .95 24.3

.50 12.7

.44 11.1 .03 0.8 .38 9.5 #10-32 THD 8X .06 1.5

.75 19.1

.63 15.9

1.48 37.6

.56 14.3 1.14 28.9 1.185 30.1 MAX

Optional Cover: C71502


2.13 54
SPECIAL PRODUCTS

((1) #4 THREAD CUTTING SCREW PROVIDED)

.04 1

1.19 30.2

MARATHON

.63 16 .79 19.9

.75 18.9

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

64

Datasheets available at marathonsp.com

Studded Power Feed Thru Terminal Blocks


ST723B38 Series (back mount)
Specifications:
Studded Power Feed Thru Terminal Blocks

Electrical:

600 Volts AC/DC (UL 1059 Class B and C) 380 Amps Wire Range 500 kcmil - 2/0 AWG Accommodates Two Hole Compression Lugs on 1 Centers - wires larger than 250 kcmil require narrow lug

Mechanical:

Base, Thermoplastic, 125oC (UL RTI) Flammability, UL 94 V-O Studs, 3/8 - 16, Brass, Nickel Plated Mounting hardware included (4) #10-32 Screws Application Torque: 192 lbf-in UL Recognized File No. XCFR2.E62806 cURus Certified File No. XCFR8.E62806 RoHS Compliant

ST723B3802

Hardware Options: (blank) No hardware UH All nuts shipped bulk AH All nuts assembled DL Assembled barrier side, remainder shipped bulk

ST723B3801 - One Pole


2.25 57.1 1.00 25.4 1.40 35.6 1.50 38.1 .81 TYP. 20.6 3/8-16 X .86" LG. TH'D BOTH ENDS 1.19 30.2 1.80 45.8 .155 TYP. 3.9 X .43 [10.9] DP. FOR #10 SCREW

1.60 40.7

.10 X .45 DP. 2.6

.56 14.2

.71 17.9

.27 6.8

1.75 44.5

.25 6.4

ST723B3802 - Two Poles


2.25 57.15 1.00 25.40 .50 12.7 .16 4 3.37 85.5 .37 9.4 3/8-16 X .86 LG. TH'D BOTH ENDS .81 20.6 TYP. .155 3.9 X .43 DP.

3.17 80.4

1.56 39.7

2.75 69.9 1.38 34.9

1.40 35.4

1.68 42.7

.104 X .45 DP 2.6 C'BORE .115 X .09 DP

.56 14.2

.69 17.6

.88 22.23 1.75 44.45 1.13 28.58

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

65

Single Stud Connection Block

Specifications:
Single Stud Connection Block
Base, Thermoplastic Temperature Rating of 125oC (UL RTI) Hardware, Stainless Steel 300 Volt AC/DC Recommended Mounting Screw 1/4 Available with two stud sizes: 5/16 or 3/8 Designed for two or more wire lugs RoHS Compliant

ST 710 38

Catalog # ST 710 31 5/16 Stud


.31 [ 8] .75 [19] .31 [ 8] 1.50 [38]

Catalog # ST 710 38 3/8 Stud


.75 [19]

1.50 [38]

2.00 [51] 3.00 [76]

.50 [13]

2.00 [51] 3.00 [76]

.50 [13]

3/8-16 UNC 5/16-18 UNC 2.29 [58] 2.54 [64] .43 [11] .43 [11]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

66

Datasheets available at marathonsp.com

Motor Terminal Blocks (IEC Style)


ST750 and ST755 Series
Specifications: Electrical:

Motor Terminal Blocks

Designed for delta and wye wiring configurations 35 to 706 Amps 300 to 1000 Volts For use with Listed crimp lugs

Mechanical:

Base, Thermoset Polyester, 130oC (UL RTI) Studs and hardware, steel, plated Link, copper, nickel plated UL Recognized File No. XCFR2.E62806 UL investigated to CSA 22.2 No. 158, File No. XCFR8.E62806 UL investigated to IEC 60947-7-1, File No. XCHG2.E243117 UL investigated to IEC 60079-15, File No. XCHG2.E243117 (pending) RoHS Compliant

Shown left to right: ST750M8 and ST750M12

Catalog Number ST755M4 ST750M4 ST755M5 ST750M6 ST750M8 ST755M10 ST755M12 ST750M12 ST750M16 ST755M16

Stud Size M4 M4 M5 M6 M8 M10 M12 M12 M16 M16 Style One piece One piece One piece One piece One piece One piece One piece Two piece Two piece One piece

Amperage UL/CSA 38A 35A 50A 100A 160A 185A 242A 315A 560A 353A IEC 50A 50A 67A UL/CSA
+

Voltage IEC 630V 800V Sans 1804 250V 1100V 660V 1100V 1100V 1100V 1100V 1100V 1100V 1100V 300V (C) 600V (C)

Wire Range (mm) Max. #8 AWG (10) #8 AWG (10) #8 AWG (10) #2 AWG (35) 2/0 AWG (120) 3/0 AWG (95) 250 kcmil (120) 400 kcmil (185) (2) 350 kcmil [(2) 185] 500 kcmil (240) Min. #18 AWG (.75) #18 AWG (.75) #16 AWG (1.5) #14 AWG (2.5) #12 AWG (4) #8 AWG (10) #8 AWG (10) #8 AWG (10) #2 AWG (35) #2 AWG (35)

1000V (E) 1000V

121A 1000V (E) 1000V 185A 1000V (E) 1000V 217A 1000V (E) 1000V 271A 1000V (E) 1000V 374A 1000V (E) 1000V 706A 1000V (E) 1000V 415A 1000V (E) 1000V

+UL/CSA Voltage Classes - C = General Industrial; E = Terminal Blocks rated 601-1500V All blocks include hardware assembled; for other hardware options, consult Customer Service See page 68 for dimensional information

Datasheets available at marathonsp.com

67

Motor Terminal Blocks (IEC Style)


Catalog Number ST755M4 ST750M4 ST755M5 Thread Size M4 x 0.7 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.5 M12 x 1.75 Two piece base M16 x 2.0 One piece base 2 3 One piece base with risers 1 Description FIG A 55.0 63.0 68.0 85.0 B 33.0 36.5 40.0 50.0 C D E F G 6.0 5.8 6.0 7.0 9.0 9.0 H 10.0 I J K N/A N/A N/A N/A N/A N/A N/A 27.0 33.0 L 16.5 18.3 21.5 27.5 36.0 45.0 55.0 27.0 33.0 M N/A N/A N/A N/A N/A N/A N/A 85.3 85.3 42.0 16.0 20.0 20.0 42.0 16.5 26.5 26.5 44.0 20.0 25.0 25.0 62.0 27.5 30.0 30.0 76.0 32.5 40.0 40.0 91.0 45.0 50.0 50.0 10.0 20.0 16.5 9.0 26.5 10.0 15.0 20.0 12.0 23.5 25.0 15.0 29.5 34.0 15.0 25.0 50.0

Motor Terminal Blocks

ST750M6 ST750M8 ST755M10 ST755M12 ST750M12 ST750M16 ST755M16

112.0 68.0 140.0 86.0

170.0 110.0 97.0 45.0 60.0 60.0 11.0 18.0 28.0 60.0 167.0 179.3 107.0 52.0 69.7 139.3 11.0 N/A 12.0 85.3 191.0 201.3 133.0 68.0 75.7 151.3 11.0 N/A 12.0 85.3 See Figure 3 for dimensions

FIGURE 1:
E

A E D

C Ref.

F B L K J

Thread

FIGURE 2:
E

A E G B F M D

C Ref.

L K J Thread

FIGURE 3:
22 75

260 216 75

110 Ref. 70

75 145 35
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

75

14 THRU

M16-2.0 6H

68

Heavy Duty Terminal Blocks


General Information:
Heavy Duty Terminal Blocks are available in two styles Deadfront Type (1100, 1200, 985 and 0987 series) and Barrier Type (1500, 1600 and 1700 series).

Ratings and Standards:


The voltage ratings of terminal blocks are based upon the minimum spacing between electrically conductive parts line to line through air and over surface, and line to ground through air and over surface. Class A Service equipment including deadfront switchboards, panel boards, service entrance devices. Class B Commercial appliances including business equipment, electronic data processing equipment and the like. Class C General industrial and machine tool controls which can be further defined as equipment falling under UL 508. Ratings based on UL 1059 may be higher in some cases depending on application.

Heavy Duty Terminal Blocks

Spacing Requirements (in inches):


Voltage Class A 51-150 151-300 301-600 51-150 151-300 301-600 51-150 151-300 301-600 Thru Air .500 .750 1.000 .063 .094 .375 .125 .250 .375 Over Surface .750 1.250 2.000 .063 .094 .500 .250 .375 .500

Class B

Class C

Applications:
These rugged terminal blocks are widely used in such industries as traffic control, utilities, switchgear and other utility related applications, such as windpower.

Datasheets available at marathonsp.com

69

Heavy Duty Terminal Blocks


1100 Series - Deadfront Type 600 Volts AC/DC (UL/CSA) 630 Volts ( )
Heavy Duty Terminal Blocks

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Connector, Aluminum Tin Plated Spring, Copper, Use 11XXS Screws, Brass, Tin Plated Current Rating up to 65 Amps Wire Range #6 - #18 AWG CU Wire Range With Spring #6 - #14 AWG CU UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
Dimensions A B 1.69 1.31 2.50 2.12 3.38 3.00 3.88 3.50 4.25 3.88 6.00 5.62
mm = dim X 25.4

1106

Catalog Number 1102 1102S 1104 1104S 1106 1106S 1107 1107S 1108 1108S 1112 1112S
S=Copper Pressure Spring See page 35 for DIN Rail Adapter

# of Poles 2 4 6 7 8 12

A B .69 [17.5]

1.38 [35.2]

.44 [11.1] .44 [11.1]

MARKER STRIP WHITE VINYL .59 [15.1]

.218 [5.5]

1.03 [26.2]

.84 [21.4]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

70

Datasheets available at marathonsp.com

Heavy Duty Terminal Blocks


1103P and 1200 Series - Deadfront Type 600 Volts AC/DC (UL/CSA) 630 Volts ( ) - 1103P 800 Volts ( ) - 1200 Series
Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Connector, Aluminum, Tin Plated Screws, Steel, Nickel (Ni) Plated Current Rating up to 70 Amps 1103P Wire Range (1) #4 - #14 AWG CU (1-2) #10 - #14 AWG CU 1200 Series Wire Range #4 - #18 AWG CU UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
Dimensions Catalog # 1202 1204 1206 # of Poles 2 4 6 A 1.81 2.81 3.81 B 1.44 2.44 3.44
mm = dim X 25.4 1206 1103P

Heavy Duty Terminal Blocks

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

"A" .19 [4.8] "B"

.19 [4.8]

2.50 [63.5] 2.13 [54.0] .22 THRU

.218 THRU 1.50 [38.1] .50 [12.7]


1.38 [34.9] .44 [11.1]

.75 [19.1]

.69 [17.5]

.50 [12.7]

.66 [16.7]

.61 [15.5]

.64 [16.3]

.81 [20.7]

1.13 [28.6]

1.13 [28.6]

.94 [23.8]

1200 Series
Datasheets available at marathonsp.com

1103P Series
71

Heavy Duty Terminal Blocks


0987 RZ Series - Deadfront Type 600 Volts AC/DC (UL/CSA) 1000 Volts ( )
Heavy Duty Terminal Blocks

Specifications:
Base, Thermoplastic, 125oC, Flammability UL 94 V-O Connector, Copper Alloy, Nickel Plated (TC Tubular Clamp) Current Rating up to 50 Amps Wire Range (1) #8 - #24 sol/str (2) 12 str (2) 14 str (1) 12 str and (1) 14 str .475 Centerline Spacing IP20 Touchproof Protection UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

0987 RZ TC 07

Dimensions Catalog # 0987 0987 0987 0987 0987 0987 0987 0987 0987 0987 0987 RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ TC TC TC TC TC TC TC TC TC TC TC 02 03 04 05 06 07 08 09 10 11 12 # of poles 2 3 4 5 6 7 8 9 10 11 12 A 0.95 1.43 1.90 2.38 2.85 3.33 3.80 4.28 4.75 5.23 5.70 B N/A 0.48 0.95 1.43 1.90 2.38 2.85 3.33 3.80 4.28 4.75

mm = dim X 25.4

"A" .48 12.1 "B"

1.26 32

.60 15.2

.72 18.2 CB DEPTH

.24 6 SECTION A-A

.475 12.1 TYP. A

.15 THRU CB .27 [ 3.8 THRU CB 6.9]

.84 21.3

.35 8.8 .12 3.1

1.26 32

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

72

Datasheets available at marathonsp.com

Heavy Duty Terminal Blocks


985 GP Series - Deadfront Type 600 Volts AC/DC (UL/CSA) 630 Volts ( )
Heavy Duty Terminal Blocks

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Connector, Aluminum, Tin (Sn) Plated Screws, Steel, Tin (Sn) Plated Current Rating up to 85 Amps Wire Range #4-#18 AWG Copper Wire Multiple Wire Combinations For Solid or Stranded Copper Wire Are: (1) #4 AWG (1) #6 AWG (1 - 2) #8 AWG (1 - 4) #10 AWG (1 - 4) #12 AWG (1 - 6) #14 AWG (1 - 6) #16 AWG (1 - 8) #18 AWG 5/8 (.625) Center-Line Spacing UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

985 GP 06

Dimensions Catalog # 985 985 985 985 985 985 985 985 985 985 985 GP GP GP GP GP GP GP GP GP GP GP 02 03 04 05 06 07 08 09 10 11 12 # of poles 2 3 4 5 6 7 8 9 10 11 12 A 1.16 1.78 2.41 3.03 3.66 4.28 4.91 5.53 6.16 6.78 7.41 B N/A 0.63 1.25 1.88 2.50 3.13 3.75 4.38 5.00 5.63 6.25

See page 35 for DIN Rail Adapter

mm = dim X 25.4

"A" "B" .27 [6.8] A


9-85 9-85 9-85 9-85

.281 TYP.

KULKA

KULKA

KULKA

A .44 [11.1] .625 [15.88]

KULKA

1.25 [31.8]

.88 [22.2]

SECTION A-A

.180 HOLE .312 C'BORE x .18 DEEP .22 [5.5]

1.13 [28.6]

TUBULAR TERMINAL

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

73

Heavy Duty Terminal Blocks


1500 Series 600 Volts AC/DC (UL/CSA) 1000 Volts ( )
Heavy Duty Terminal Blocks
1508 STD

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Connector, Brass, Nickel Plated Phil-Slot Screws standard (slotted screws also available), Brass, Nickel Plated, 10-32 Current rated up to 30 Amps with unprepared wire, #10-22 AWG Copper Current rated up to 75 Amps when wired with crimp type ring, spade or fork terminal 5/8 (.625) Line To Line Spacing UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
Dimensions # of Poles 2 4 6 8 12 1502 MCJ 1504 MCJ 1506 MCJ 1508 MCJ 1512 MCJ 1502 STD 1504 STD 1506 STD 1508 STD 1512 STD 1502 DJ 1504 DJ 1506 DJ 1508 DJ 1512 DJ Catalog # 1502 DJSV 1504 DJSV 1506 DJSV 1508 DJSV 1512 DJSV 1502 ST 1504 ST 1506 ST 1508 ST 1512 ST 1502 SC 1504 SC 1506 SC 1508 SC 1512 SC 1502 H 1504 H 1506 H 1508 H 1512 H A 2.00 3.25 4.50 5.75 8.25 B 1.62 2.88 4.12 5.38 7.88
mm = dim X 25.4

1508 SC

See page 35 for DIN Rail Adapter

15XX MCJ

15XX STD

15XX DJ

15XX DJSV

15XX ST*

15XX SC

15XX H

Multiple Circuit Jumper

Standard Connector with Serrations for Anti-Rotation

Removable Connector with Brass Insert

Removable Connector with Brass Insert, Removable Cover

10-32 Stud, Removable Connector

Short Circuiting Bar with Brass Insert, 4 Shorting Pins per Block

Standard Connector with Hinge Cover

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


"A" .19 [4.8]

* STRC: 10-32 Stud with Riveted Connector


1.19 [30.2] .38 [9.5]

"B"

.375 [9.53] 1.00 [25.4] 2.00 [50.8] .22 [5.6] .50 [12.7] .625 [15.88] .50 [12.7]

74

Datasheets available at marathonsp.com

Heavy Duty Terminal Blocks


1600 Series 600 Volts AC/DC (UL/CSA) 1000 Volts ( )
Heavy Duty Terminal Blocks

Specifications:
Base, General Purpose Phenolic, 150 C (UL RTI) Connector, Brass, Nickel Plated Phil-Slot Screws standard (slotted screws also available), Brass, Nickel Plated, 10-32 Current rated up to 30 Amps with unprepared wire, #10-22 AWG Copper Current rated up to 75 Amps when wired with crimp type ring, spade or fork terminal 21/32 (.65625) Line To Line Spacing UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
o

1604 H

1606 STD

Dimensions # of Poles 2 4 6 8 12 1602 MCJ 1604 MCJ 1606 MCJ 1608 MCJ 1612 MCJ 1602 STD 1604 STD 1606 STD 1608 STD 1612 STD 1602 DJ 1604 DJ 1606 DJ 1608 DJ 1612 DJ Catalog # 1602 DJSV 1604 DJSV 1606 DJSV 1608 DJSV 1612 DJSV 1602 ST 1604 ST 1606 ST 1608 ST 1612 ST 1602 SC 1604 SC 1606 SC 1608 SC 1612 SC 1602 H 1604 H 1606 H 1608 H 1612 H A 2.44 3.75 5.06 6.38 9.00 B 1.78 3.09 4.41 5.72 8.34
mm = dim X 25.4

See page 35 for DIN Rail Adapter

16XX MCJ

16XX STD

16XX DJ

16XX DJSV

16XX ST*

16XX SC

16XX H

Multiple Circuit Jumper

Standard Connector with Serrations for Anti-Rotation

Removable Connector with Brass Insert

Removable Connector with Brass Insert, Removable Cover

10-32 Stud, Removable Connector

Short Circuiting Bar with Brass Insert, 4 Shorting Pins per Block

Standard Connector with Hinge Cover

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


"A"

* STRC: 10-32 Stud with Riveted Connector


1.19 [30.2] .63 [15.9]

"B"

.33 [8.4]

1.00 [25.4]

2.00 [50.8]

.66 [16.7] .56 [14.3] .50 [12.7] .250 X .375 [6.3] [9.5] SLOT

.50 [12.7]

Datasheets available at marathonsp.com

75

Heavy Duty Terminal Blocks


1700 Series 600 Volts AC/DC (UL/CSA) 1000 Volts ( )
Heavy Duty Terminal Blocks

1708 SC

Specifications:
Base, Thermoplastic, 125oC (UL RTI) Serrated Connectors, Brass, Nickel Plated Screws, Brass, Nickel Plated, 10-32 Current rated up to 30 Amps with unprepared wire, #10-22 AWG Copper Current rated up to 75 Amps when wired with crimp type ring, spade or fork lugs 5/8 (.625) Line To Line Spacing UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
Standard Terminal 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 STD STD STD STD STD STD STD STD STD STD STD Short Circuit Terminal 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 SC SC SC SC SC SC SC SC SC SC SC Dimensions A B 2.00 2.63 3.25 3.88 4.50 5.13 5.75 6.38 7.00 7.63 8.25 1.64 2.26 2.89 3.51 4.14 4.76 5.39 6.01 6.64 7.26 7.89 Clear Cover CC CC CC CC CC CC CC CC CC CC CC 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712

1708 STD

# of Poles 2 3 4 5 6 7 8 9 10 11 12

1700 series optional clear cover

STD = Standard Terminal - Connector Plate, 2 Phil-Slot Screws, Center M/S SC = Short Circuit Terminal (Pin to be torqued to 5 in-lbs) CC = Clear PVC snap on cover, sized to fit and protect See page 35 for DIN Rail Adapter
"A" "B"

mm = dim X 25.4

.18 4.64

1.41 35.69 .26 6.60

.75 19.07 2.00 50.80 1.50 38.15 .21 5.33

.50 12.80

.63 15.88

.54 13.59

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

76

Double Row Terminal Blocks


General Information:
Double Row Terminal Blocks are available in many line to line spacings. Open and closed back designs are available as shown in table below. Insulator bases are available in both phenolic and thermoplastic material. Modifications are also provided on most terminal blocks, including marking strips.

Ratings and Standards:


The voltage ratings of terminal blocks are based upon the minimum spacing between electrically conductive parts line to line through air and over surface and line to ground through air and over surface. Class A: Service, including deadfront switchboards, panel boards, service equipment and the like. Class B: Commercial appliances including business equipment, electronic data processing equipment and the like. Class C: Industrial, general

Double Row Terminal Blocks

Spacing Requirements (in inches):


Voltage Thru Air Over Surface

Class A Class B Class C

51-150 151-300 301-600 51-150 151-300 301-600 51-150 151-300 301-600

0.500 0.750 1.000 0.063 0.094 0.375 0.125 0.250 0.375

0.750 1.250 2.000 0.063 0.094 0.500 0.250 0.375 0.500

Reference Chart:
Series 100/670A GP 200/671 GP 300/672 GP 400 410* 600* 600A* 800A* 601* 801* 602* 802* 603* 604* 605* 621 RZ 670A RZ 671 RZ 672 RZ Voltage Rating* Catalog Page Amps Class B Class C N/A 20 78 300+ 79 80 81 82 83 84 84 85 85 86 86 87 88 89 90 91 92 93 20 30 30 5 15 15 15 20 20 30 30 50 70 90 20 20 20 30 300+ N/A N/A 300
+

Base Material Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Thermoplastic Thermoplastic Thermoplastic Thermoplastic

Max Screw Inches Number Features Wire Size Size L to L of Lines #12 Closed Back .375 6-32 1-36 #12 #10 #10 #18 #12 #12 #12 #12 #12 #12 #12 #10 #4 #2 #12 #12 #12 #10 6-32 8-32 10-32 2-56 5-40 6-32 6-32 6-32 6-32 8-32 8-32 10-32 12-32 1/4-28 6-32 6-32 6-32 8-32 .437 .562 .687 .250 .375 .375 .375 .437 .437 .562 .562 .687 .875 1.125 .437 .375 .437 .562 1-30 1-24 1-12 1-23 1-22 1-22 1-22 1-23 1-23 1-26 1-26 1-12 1-8 1-6 1-30 1-30 1-30 1-24 Closed Back Closed Back Closed Back Open Back Open Back Open Back Open Back Open Back Open Back Open Back Open Back Open Back Open Back Open Back Closed Back/High Barrier Closed Back Closed Back Closed Back

N/A 600 600 N/A 150 150 150 300 150 300 150 600 600 600 600 150 N/A 600

300 300 N/A 300 N/A 300 N/A 600 600 600 600 300
+

300+ 600

*Open back terminal blocks require an insulator strip to achieve voltage rating.
+

Ratings pending UL investigation.

Datasheets available at marathonsp.com

77

Double Row Terminal Blocks


100 Series Kulka 670A GP Series 300 Volts AC/DC (Class B)
Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Closed Back Design Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-36 Poles 3/8 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps
Kulka Catalog # 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 A 1.03 1.41 1.78 2.16 2.53 2.91 3.28 3.66 4.03 4.41 4.78 5.16 5.53 5.91 6.28 6.66 7.03 7.41 7.78 8.16 8.53 8.91 9.28 9.66 10.03 10.41 10.78 11.16 11.53 11.91 12.28 12.66 13.03 13.41 13.78 14.16 B 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63 9.00 9.38 9.75 10.13 10.50 10.88 11.25 11.63 12.00 12.38 12.75 13.13 13.50 13.88
106 / 670A GP 06

Double Row Terminal Blocks

Wire Range With Sems Pressure Screw #18 - #22 AWG Stranded Copper Wire Only, 150 Volts 15 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

MSP Catalog # 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA F1 KT19 F2 KT20 F3 KT21 HF1 KT25 HF2 KT26 HF3 KT27 S ST HS 3/4 ST L Y LSL YSY LL 100 J 600 600RJ(S) LWW 3000 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.312) Feed Thru Solder (.500) Line to Line Jumper Multiple Position Jumper Feed Thru Wire Wrap (.593) Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 106 See page 106 See page 107 See page 107 Consult C/S Consult C/S

Quick Connects: .020 x .187


See pages 104-115 for terminal block accessories

"A"

.44 [11.1] .14 [3.6] .30 [7.6]

"B"

.28 [7.1]

.56 [14.3]

.88 [22.2]

.38 [9.5] #6-32 X .25 [6.4] BD HD SCREW

.31 [7.9]

.16 [4.1]

mm=dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

78

Datasheets available at marathonsp.com

Double Row Terminal Blocks


200 Series Kulka 671 GP Series 300 Volts AC/DC (Class B)
206 / 671 GP 06

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Closed Back Design Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-30 Poles 7/16 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps
Kulka Catalog # 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A 1.19 1.62 2.06 2.50 2.94 3.37 3.81 4.25 4.69 5.12 5.56 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 10.37 10.81 11.25 11.69 12.12 12.56 13.00 13.44 13.87 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50 10.94 11.38 11.81 12.25 12.69 13.13 13.56

Wire Range With Sems Pressure Screw #12 - #22 AWG Stranded Copper Wire Only, 20 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

MSP Catalog # 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA F1 KT37 F2 KT38 F3 KT39 HF1 KT43 HF2 KT44 HF3 KT45 S ST HS 3/4 ST L Y LSL YSY LL 200 J 601 601RJ(S) SP 3765 SPSE 3767 LWW PSB 4000

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.437) Feed Thru Solder (.625) Line to Line Jumper Multiple Position Jumper SEMS Pressure Saddle Screw SEMS Pressure Saddle Screw with External Tooth Lock Washer Feed Thru Wire Wrap (.640) Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 106 See page 106 See page 107 See page 107 See page 107 Consult C/S Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .16 [4.1] .175 [4.4] B .34 [8.6] .53 [13.5] .34 [8.7]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.44 [11.1] #6-32 X .25[6.4] BD HD SCREW .42 [10.7]

.75 [19.1]

1.12 [28.5]

Datasheets available at marathonsp.com

79

Double Row Terminal Blocks


300 Series Kulka 672 GP Series 600 Volts AC/DC (Class C)
306 / 672 GP 06

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Closed Back Design Screws, #8-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-24 Poles 9/16 Centers Wire Range With Wire Binding Screw #10 - #14 AWG 30 Amps
Kulka Catalog # 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A 1.54 2.10 2.66 3.22 3.79 4.35 4.91 5.47 6.04 6.60 7.16 7.72 8.29 8.85 9.41 9.97 10.54 11.10 11.66 12.22 12.79 13.35 13.91 14.47 B 1.13 1.69 2.25 2.81 3.38 3.94 4.50 5.06 5.63 6.19 6.75 7.31 7.88 8.44 9.00 9.56 10.13 10.69 11.25 11.81 12.38 12.94 13.50 14.06

Double Row Terminal Blocks

Wire Range With Sems Pressure Screw #10 - #22 AWG Stranded Copper Wire Only, 30 Amps Will Accommodate Lugs for Wire Sizes #10 - #16 AWG, 30 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

MSP Catalog # 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA F1 KT55 F2 KT56 F3 KT57 HF1 KT61 HF2 KT62 HF3 KT63 S ST HS 3/4 ST L Y LSL YSY LL 300 J 602 SP 3786 SPSE LWW PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.437) Feed Thru Solder (.625) Line to Line Jumper SEMS Pressure Saddle Screw SEMS Pressure Saddle Screw with External Tooth Lock Washer Feed Thru Wire Wrap (1.00) Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 106 See page 106 See page 107 See page 107 Consult C/S Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories

A .21 [5.3] .56 B .203 [5.2]

.71 [18.0] .45 [11.4]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

[14.3]

.94 [24.0]

1.31 [33.3]

.42 [10.7] #8-32 X 0.31[7.9] BD HD SCREW

.50 [12.7]

80

Datasheets available at marathonsp.com

Double Row Terminal Blocks


400 Series 600 Volts AC/DC (Class C)
406

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Closed Back Design Screws, #10-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-12 Poles 11/16 Centers Wire Range With Wire Binding Screw #10 - #22 AWG 30 Amps Wire Range With Sems Pressure Screw #10 - #22 AWG Stranded Copper Wire Only, 30 Amps Will Accommodate Lugs for Wire Sizes #6 - #16 AWG, 65 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

MSP Catalog # 401 402 403 404 405 406 407 408 409 410 411 412

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 A 1.81 2.50 3.19 3.88 4.56 5.25 5.94 6.62 7.31 8.00 8.68 9.37 B 1.38 2.06 2.75 3.44 4.12 4.81 5.50 6.19 6.88 7.56 8.25 8.94

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA F1 KT64 F2 KT65 F3 KT66 HF1 KT67 HF2 KT68 HF3 KT69 LL 400 J 603 SPSE PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Line to Line Jumper SEMS Pressure Saddle Screw Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 107 Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

A .22 [5.6] .69 [17.5] B .21 [5.3]

.75 [19.1]

.44 [11.1]

1.06 [27.0]

1.81 [46.0]

.47 [12.0]

#10-32 X .38[9.5] BD HD SCREW

.63 [15.9]

Datasheets available at marathonsp.com

81

Double Row Terminal Blocks


Kulka 410 GP Series 300 Volts AC/DC (Class B)
410 GP 06 PSB

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #2-56 x 7/32 Binder Head, Phil-Slot, Brass Terminals, Plated Brass 1-23 Poles 1/4 Centers Wire Range With Wire Binding Screw #18 - #20 AWG 5 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Kulka Catalog # 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 410 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00 6.25 B 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA ST 3/4 ST Y J 410 1921

PRODUCT DESCRIPTION Full Solder Half Solder Feed Thru Solder (.437) Line to Line Jumper Printed Circuit Pin (.109)

PAGE REFERENCE See page 106 See page 106 See page 106 See page 107 Consult C/S

Quick Connects: .020 x .110


See pages 104-115 for terminal block accessories
.32 A .13 [3.2] [8.2]

B .22 [5.7] .25 [6.4]

.13 [3.2]

.63 [15.9]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.19 [4.8] #2-56 X .22[5.6] BD HD SCREW .25 [6.4]

82

Datasheets available at marathonsp.com

Double Row Terminal Blocks


Kulka 600 GP Series 300 Volts AC/DC (Class B) 150 Volts AC/DC (Class C)
600 GP 07 PSB

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #5-40 Binder Head, Phil-Slot, Brass Terminals, Plated Brass 1-22 Poles 3/8 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 15 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Kulka Catalog # 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB PSB

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 A 1.03 1.41 1.78 2.16 2.53 2.91 3.28 3.66 4.03 4.41 4.78 5.16 5.53 5.91 6.28 6.66 7.03 7.41 7.78 8.16 8.53 8.91 B 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63
.14 [3.6]

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT19 KT20 KT21 KT25 KT26 KT27 ST 3/4 ST Y YSY Z J 600 600 RJ(S) 2004

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.312) Feed Thru Solder (.500) Lug Over the Side (.625) Line to Line Jumper Multiple Position Jumper Feed Thru Solder

PAGE REFERENCE See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 106 See Page 106 See Page 106 See Page 106 See Page 106 See Page 107 See Page 107 See Page 109

Quick Connects: .020 x .187


See pages 104-115 for terminal block accessories
A B .38 .18 [4.4] .41 [10.3] .25 [6.4]

mm=dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

[9.5]

.56 [14.3]

.87 [22.1]

.30 [7.6] #5-40 X .25[6.4] BH HD SCREW

.31 [7.9]

Datasheets available at marathonsp.com

83

Double Row Terminal Blocks


Kulka 600A/800A GP Series 300 Volts AC/DC (Class B)
600A Series only

150 Volts AC/DC (Class C)


600A and 800A Series

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-22 Poles 3/8 Centers

600A GP 06

Double Row Terminal Blocks

Wire Range With Wire Binding Screw #12 - #22 AWG 15 Amps 800A Series (Riveted KTs) - see page 105 UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Kulka Catalog # 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A 600A GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 A 1.03 1.41 1.78 2.16 2.53 2.91 3.28 3.66 4.03 4.41 4.78 5.16 5.53 5.91 6.28 6.66 7.03 7.41 7.78 8.16 8.53 8.91 B 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT19 KT20 KT21 KT25 KT26 KT27 ST 3/4 ST Y YSY Z J 600 600 RJ(S) 3860 3865 2002 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.312) Feed Thru Solder (.500) Lug Over the Side (.625) Line to Line Jumper Multiple Position Jumper Wire Clamp Screw, Brass Wire Clamp Screw Stud Phil-Slot Brass Screw

PAGE REFERENCE See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 106 See Page 106 See Page 106 See Page 106 See Page 106 See Page 107 See Page 107 See Page 107 See Page 107 See Page 109 Consult C/S

Quick Connects: .020 x .187


See pages 104-115 for terminal block accessories
A .14 .18 B .38 [9.5] [4.4] .41 [10.3] .25 [6.4]

mm=dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

[3.6]

.56 [14.2] .30 [7.6] #6-32 X .25[6.4] BD HD SCREW .31 [7.9]

.87 [22.1]

84

Datasheets available at marathonsp.com

Double Row Terminal Blocks


Kulka 601/801 GP Series 300 Volts AC/DC (Classes B/C)
601 Series only 801 Series only

150 Volts AC/DC (Class C)


Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-23 Poles 7/16 Centers
601 GP 06

Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps 801 Series (Riveted KTs) - see page 105 UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Kulka Catalog # 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 601 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1.19 1.62 2.06 2.50 2.94 3.37 3.81 4.25 4.69 5.12 5.56 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 10.37 10.81 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT37 KT38 KT39 KT43 KT44 KT45 ST 3/4 ST Y YSY J 601 601 RJ(S) 3765 3760 2102 2104 2108 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.422) Feed Thru Solder (.687) Line to Line Jumper Multiple Position Jumper Wire Clamp Screw Wire Clamp Screw Stud Feed Thru Solder Individual Screw Terminals Phil-Slot Brass Screw

PAGE REFERENCE See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 106 See Page 106 See Page 106 See Page 106 See Page 107 See Page 107 See Page 107 See Page 107 See Page 109 See Page 109 See Page 109 Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .16 B .44 [11.1] .50 [12.7] .18 [4.5] .31 [7.9]

mm=dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

[4.0]

.75 [19.1] .42 .34 [8.6] #6-32 X .25[6.4] BD. HD. SCREW [10.7]

1.13 [28.7]

Datasheets available at marathonsp.com

85

Double Row Terminal Blocks


Kulka 602/802 GP Series 300 Volts AC/DC (Classes B/C)
602 Series only 802 Series only

150 Volts AC/DC (Class C)


Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #8-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-26 Poles

602 GP 06

Double Row Terminal Blocks

9/16 Centers Wire Range With Wire Binding Screw #10 - #18 AWG 30 Amps 802 Series (Riveted KTs) - see page 105 UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Kulka Catalog # 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 602 GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 A 1.54 2.10 2.66 3.22 3.79 4.35 4.91 5.47 6.04 6.60 7.16 7.72 8.29 8.85 9.41 9.97 10.54 11.10 11.66 12.22 12.79 13.35 13.91 14.47 15.04 15.60 B 1.13 1.69 2.25 2.81 3.38 3.94 4.50 5.06 5.63 6.19 6.75 7.31 7.88 8.44 9.00 9.56 10.13 10.69 11.25 11.81 12.38 12.94 13.50 14.06 14.63 15.19

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT55 KT56 KT57 KT61 KT62 KT63 ST 3/4 ST Y YSY Z J 602 3786 2202 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.500) Feed Thru Solder (.672) Lug over the Side (.609) Line to Line Jumper Wire Clamp Screw Stud Phil-Slot Brass Screw

PAGE REFERENCE See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 106 See Page 106 See Page 106 See Page 106 See Page 106 See Page 107 See Page 107 See Page 109 Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .20 [5.2] B .56 [14.3] .21 [5.4] .38 [9.7] .64 [16.1]

mm=dim X 25.4

.88

1.32 [33.4]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


.44 [11.1] #8-32 X .31[7.9] BD HD SCREW .50 [12.7]

[22.4]

86

Datasheets available at marathonsp.com

Double Row Terminal Blocks


Kulka 603 GP Series 600 Volts AC/DC (Classes B/C)
603 GP 06

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #10-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-12 Poles 11/16 Centers Wire Range With Wire Binding Screw #10 - #16 AWG 30 Amps 50 Amps with Listed Wire Lugs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Kulka Catalog # 603 603 603 603 603 603 603 603 603 603 603 603 GP GP GP GP GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 09 10 11 12

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 A 1.81 2.50 3.19 3.88 4.56 5.25 5.94 6.62 7.31 8.00 8.68 9.37 B 1.38 2.06 2.75 3.44 4.12 4.81 5.50 6.19 6.88 7.56 8.25 8.94

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT67 KT68 KT69 KT64 KT65 KT66 Y J 603 2302 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Feed Thru Solder (.60) Line to Line Jumper Stud Phil-Slot Brass Screw

PAGE REFERENCE See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 105 See Page 106 See Page 107 See Page 109 Consult C/S

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories

.75 [19.1]

B .20 [5.2] THRU C'BORE .25 [6.4] X .09 [2.3] DP. .44 [11.1]

.22 [5.5]

.69 [17.4]

1.06 [27.0] .63 .48 [12.1] #10-32 X .38 [9.5] BD HD SCREW [15.9]

1.31 [33.3]

1.81 [46.0]

Datasheets available at marathonsp.com

87

Double Row Terminal Blocks


Kulka 604 GP Series 600 Volts AC/DC (Classes B/C)
604 GP 04

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #12-32 Binder Head, Phil-Slot, Brass Terminals, Plated Brass 1-8 Poles

Double Row Terminal Blocks

7/8 Centers Wire Range With Wire Binding Screw #10 - #12 AWG 30 Amps 70 Amps with Listed Wire Lugs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Kulka Catalog # 604 604 604 604 604 604 604 604 GP GP GP GP GP GP GP GP 01 02 03 04 05 06 07 08 PSB PSB PSB PSB PSB PSB PSB PSB

Dimensions # of poles 1 2 3 4 5 6 7 8 A 2.28 3.16 4.03 4.91 5.78 6.66 7.53 8.41 B 1.75 2.63 3.50 4.38 5.25 6.13 7.00 7.88

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA J 604 2402

PRODUCT DESCRIPTION Line to Line Jumper Stud 10-32 Brass (.43 H) Nuts included

PAGE REFERENCE See Page 107 See Page 109

See pages 104-115 for terminal block accessories

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.94 A .27 [6.8] .88 [22.2] B [23.8] .23 [5.9] .50 [12.7]

1.25 [31.8]

2.00 [50.8]

.58 [14.6] .75 #12-32 X .38[9.5] BD HD SCREW [19.1]

88

Datasheets available at marathonsp.com

Double Row Terminal Blocks


Kulka 605 GP Series 600 Volts AC/DC (Classes B/C)

Specifications:
Base, General Purpose Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #1/4-28 Binder Head, Slotted, Brass Terminals, Plated Brass 1-6 Poles

605 GP 03

1 1/8 Centers Wire Range With Wire Binding Screw #10 - #12 AWG 30 Amps 90 Amps with Listed Wire Lugs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Kulka Catalog # 605 605 605 605 605 605 GP GP GP GP GP GP 01 02 03 04 05 06 SLB SLB SLB SLB SLB SLB

Dimensions # of poles 1 2 3 4 5 6 A 2.88 4.00 5.13 6.25 7.38 8.50 B 2.25 3.38 4.50 5.63 6.75 7.88

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA J 605 2502 PSB

PRODUCT DESCRIPTION Line to Line Jumper Stud 1/4-28 Brass (.750 H) Nuts included Phil-Slot Brass Screw

PAGE REFERENCE See Page 107 See Page 109 Consult C/S

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

See pages 104-115 for terminal block accessories

A .34 [8.5] 1.13 [28.6] B

1.13 [28.6] .27 [6.7] .63 [15.9]

1.48 [37.6]

2.48 [63.1]

#1/4-28 X .50[12.7] .67 [17.0] BD HD SCREW

.88 [22.2]

Datasheets available at marathonsp.com

89

Double Row Terminal Blocks


621 RZ Series 600 Volts AC/DC (Classes B/C)
621 RZ 06

Specifications:
Base, Thermoplastic, 125oC (UL RTI) Closed Back Design Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-30 Poles 7/16 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps
Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A 1.19 1.62 2.06 2.50 2.94 3.37 3.81 4.25 4.69 5.12 5.56 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 10.37 10.81 11.25 11.69 12.12 12.56 13.00 13.44 13.87 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50 10.94 11.38 11.81 12.25 12.69 13.13 13.56

Double Row Terminal Blocks

Wire Range With Sems Pressure Screw #12 - #22 AWG Stranded Copper Wire Only, 20 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

MSP Catalog # 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 621 RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT37 KT38 KT39 KT43 KT44 KT45 ST 3/4 ST J 621 601RJ(S) 3765 3767 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Line to Line Jumper Multiple Position Jumper SEMS Pressure Saddle Screw SEMS Pressure Saddle Screw with External Tooth Lock Washer Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 107 See page 107 See page 107 Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .16 [4.1] .75 [19.1] B .44 [11.1] .18 [4.6] .38 [9.5]

.72 [18.4]

1.38 [34.9]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.33 [8.3] #6-32 X .25[6.4] BD HD SCREW .42 [10.7]

90

Datasheets available at marathonsp.com

Double Row Terminal Blocks


670A RZ Series 300 Volts AC/DC (Class B) 150 Volts AC/DC (Class C)
Specifications:
Base, Thermoplastic, 130oC (UL RTI) Closed Back Design Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-30 Poles 3/8 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps
MSP Catalog # 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A 670A RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A 1.03 1.41 1.78 2.16 2.53 2.91 3.28 3.66 4.03 4.41 4.78 5.16 5.53 5.91 6.28 6.66 7.03 7.41 7.78 8.16 8.53 8.91 9.28 9.66 10.03 10.41 10.78 11.16 11.53 11.91 B 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63 9.00 9.38 9.75 10.13 10.50 10.88 11.25 11.63
670A RZ 06

Wire Range With Sems Pressure Screw #14 - #22 AWG Stranded or Solid Wire - 15 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT19 KT20 KT21 KT25 KT26 KT27 ST 3/4 ST L Y J 600 600RJ(S) 3865 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Feed Thru Solder (.312) Line to Line Jumper Multiple Position Jumper Sems Pressure Saddle Screw Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 106 See page 107 See page 107 See page 107 Consult C/S

Quick Connects: .020 x .187


See pages 104-115 for terminal block accessories
.48 [12.1] .17 .38 [9.5] A .70 [17.8] A .31 #6-32 X .25[6.4] BD HD SCREW [7.9] .87 [22.2] SECTION A-A [4.3]

A .14 [3.6] B

.26 [6.6] .28 [7.1]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.31 [7.9]

Datasheets available at marathonsp.com

91

Double Row Terminal Blocks


671 RZ Series 300 Volts AC/DC (Class B)
671 RZ 06

Specifications:
Base, Thermoplastic, 125oC (UL RTI) Closed Back Design Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-30 Poles 7/16 Centers Wire Range With Wire Binding Screw #12 - #22 AWG 20 Amps
Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A 1.19 1.62 2.06 2.50 2.94 3.37 3.81 4.25 4.69 5.12 5.56 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 10.37 10.81 11.25 11.69 12.12 12.56 13.00 13.44 13.87 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50 10.94 11.38 11.81 12.25 12.69 13.13 13.56

Double Row Terminal Blocks

Wire Range With Sems Pressure Screw #12 - #22 AWG Stranded Copper Wire Only, 20 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant

MSP Catalog # 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 671 RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT37 KT38 KT39 KT43 KT44 KT45 ST 3/4 ST J 601 601RJ(S) 3765 3767 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Line to Line Jumper Multiple Position Jumper SEMS Pressure Saddle Screw SEMS Pressure Saddle Screw with External Tooth Lock Washer Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 107 See page 107 See page 107 Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .16 [4.1] B .18 .44 [11.1] [4.6] .35 [8.8] .53 [13.5]

.72 [18.4]

1.13 [28.6]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.33 [8.3] #6-32 X .25[6.4] BD HD SCREW .42 [10.7]

92

Datasheets available at marathonsp.com

Double Row Terminal Blocks


672 RZ Series 600 Volts AC/DC (Classes B/C)
672 RZ 06

Specifications:
Base, Thermoplastic, 125oC (UL RTI) Closed Back Design Screws, #8-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-24 Poles 9/16 Centers Wire Range With Wire Binding Screw #10 - #14 AWG 30 Amps
Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 A 1.54 2.10 2.66 3.22 3.79 4.35 4.91 5.47 6.04 6.60 7.16 7.72 8.29 8.85 9.41 9.97 10.54 11.10 11.66 12.22 12.79 13.35 13.91 14.47 B 1.13 1.69 2.25 2.81 3.38 3.94 4.50 5.06 5.63 6.19 6.75 7.31 7.88 8.44 9.00 9.56 10.13 10.69 11.25 11.81 12.38 12.94 13.50 14.06

Wire Range With Sems Pressure Screw #10 - #22 AWG Stranded Copper Wire Only, 30 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Double Row Terminal Blocks

MSP Catalog # 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 672 RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ RZ 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT55 KT56 KT57 KT61 KT62 KT63 ST 3/4 ST J 602 3786 3787 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Line to Line Jumper SEMS Pressure Saddle Screw Sems Pressure Saddle Screw with External Tooth Lock Washer Phil-Slot Brass Screw

PAGE REFERENCE See page 105 See page 105 See page 105 See page 105 See page 105 See page 105 See page 106 See page 106 See page 107 See page 107 Consult C/S Consult C/S

Quick Connects: .032 x .250


See pages 104-115 for terminal block accessories
A .71 .21 [5.2] B .22 [5.6] .45 .56 [14.3] [11.5] [18.0]

mm=dim X 25.4
For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.41 [10.4] #8-32 X .38[9.5] BD HD SCREW .84 [21.4] 1.31 [33.3]

.50 [12.7]

Datasheets available at marathonsp.com

93

Single Row Terminal Blocks


General Information:
Single Row Terminal Blocks are available in four basic line to line molding sizes. Some are available in either open or feed thru/printed circuit designs. The basic material is phenolic. Modifications are also provided on most terminal blocks, including marking strips.

Ratings and Standards:


The voltage ratings of terminal blocks are based upon the minimum spacing between electrically conductive parts line to line through air and over surface and line to ground through air and over surface. Class A Service equipment including deadfront switchboards, panel boards, service entrance devices. Class B Commercial appliances including business equipment, electronic data processing equipment and the like.

Single Row Terminal Blocks

Class C Industrial, general Ratings based on UL 1059 may be higher in some cases depending on application.

Spacing Requirements (in inches):


Voltage Thru Air Over Surface

Class A Class B Class C

51-150 151-300 301-600 51-150 151-300 301-600 51-150 151-300 301-600

0.500 0.750 1.000 0.063 0.094 0.375 0.125 0.250 0.375

0.750 1.250 2.000 0.063 0.094 0.500 0.250 0.375 0.500

Reference Chart:
Series 411 599* 799* 699* 899* 812* 912* 1690 2590 2690 Catalog Page 95 96 96 97 97 98 98 99-100 101 102-103 Voltage Rating Amps Class B Class C 5 15 15 20 20 30 30 20 15 20 300+ 300+ 300+ N/A 600 N/A N/A 300+ 300+ 300+ N/A 150 150 150 600 150 300 150 150 150 Base Material Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Phenolic Max Wire Size #18 #16 #16 #14 #14 #12 #12 #14 #16 #14 Screw Size 2-56 5-40 5-40 6-32 6-32 8-32 8-32 6-32 6-32 6-32/8-32 Inches L to L .250 .375 .375 .437 .437 .562 .562 .437 .375 .437 # of Lines 1-23 1-30 1-30 1-23 1-23 1-18 1-18 1-25 1-25 1-25 Features Open Back Open Back Open Back Open Back Open Back Open Back Open Back Feed Thru Printed Circuit Printed Circuit

+Ratings pending UL investigation *Open back terminal blocks require an insulator strip to achieve voltage rating.

94

Single Row Terminal Blocks


Kulka 411 GP Series 300 Volts AC/DC (Class B)
411 GP 06 PSB

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip Required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #2-56 Binder Head, Phil-Slot, Brass Terminals, Plated Brass 1-23 Poles 1/4 Centers Wire Range With Wire Binding Screw #18 - #20 AWG 5 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

Single Row Terminal Blocks

Kulka Catalog # 411 GP 01 PSB 411 GP 02 PSB 411 GP 03 PSB 411 GP 04 PSB 411 GP 05 PSB 411 GP 06 PSB 411 GP 07 PSB 411 GP 08 PSB 411 GP 09 PSB 411 GP 10 PSB 411 GP 11 PSB 411 GP 12 PSB 411 GP 13 PSB 411 GP 14 PSB 411 GP 15 PSB 411 GP 16 PSB 411 GP 17 PSB 411 GP 18 PSB 411 GP 19 PSB 411 GP 20 PSB 411 GP 21 PSB 411 GP 22 PSB 411 GP 23 PSB
mm = dim X 25.4

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00 6.25 B 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT10 KT11 KT12 KT16 KT17 KT18 ST 3/4 ST Z J 410 1921 1904

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Solder Half Solder Lug over the Side (.312) Line to Line Jumper Printed Circuit Pin (.125) (Over the Side) Feed Thru Solder

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 See page 106 Consult C/S See page 107 Consult C/S Consult C/S

Quick Connects: .020 x .110 See pages 104-115 for terminal block accessories

"A" .31 [7.9] "B" .13 [3.2] .25 .19 [6.4] .22 [5.5] .09 [2.4]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

[4.8]

#2-56 X .22 [5.5] BD HD SCREW .13 [3.2] .17 [4.3]

.41 [10.3]

Datasheets available at marathonsp.com

95

Single Row Terminal Blocks


Kulka 599/799 GP Series 300 Volts AC/DC (Class B)
599 Series only

150 Volts AC/DC (Class C)


599 and 799 Series

599 GP 06 PSB

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip Required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #5-40 Binder Head, Phil-Slot, Brass Terminals, Plated Brass 1-30 Poles 3/8 Centers
Kulka Catalog # 599 GP 01 PSB 599 GP 02 PSB 599 GP 03 PSB 599 GP 04 PSB 599 GP 05 PSB 599 GP 06 PSB 599 GP 07 PSB 599 GP 08 PSB 599 GP 09 PSB 599 GP 10 PSB 599 GP 11 PSB 599 GP 12 PSB 599 GP 13 PSB 599 GP 14 PSB 599 GP 15 PSB 599 GP 16 PSB 599 GP 17 PSB 599 GP 18 PSB 599 GP 19 PSB 599 GP 20 PSB 599 GP 21 PSB 599 GP 22 PSB 599 GP 23 PSB 599 GP 24 PSB 599 GP 25 PSB 599 GP 26 PSB 599 GP 27 PSB 599 GP 28 PSB 599 GP 29 PSB 599 GP 30 PSB
mm = dim X 25.4 For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com
.17 [4.2]

Single Row Terminal Blocks

Wire Range With Wire Binding Screw #16 - #22 AWG 15 Amps 799 Series (Riveted KTs) - shown at right, see page 104 for KTs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

799 Series

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 A 1.03 1.41 1.78 2.16 2.53 2.91 3.28 3.66 4.03 4.41 4.78 5.16 5.53 5.91 6.28 6.66 7.03 7.41 7.78 8.16 8.53 8.91 9.28 9.66 10.03 10.41 10.78 11.16 11.53 11.91 B 0.75 1.12 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63 9.00 9.38 9.75 10.13 10.50 10.88 11.25 11.63

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT28 KT29 KT30 KT34 KT35 KT36 3/4 ST Z J 600 600 RJ(S) 2002 2004 2020 2021

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Lug over the Side (.312) Line to Line Jumper Multiple Position Jumper Stud Feed Thru Solder Solder Pin Solder Pin (Slotted Screw)

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 Consult C/S See page 107 See page 107 See page 109 See page 109 See page 109 See page 109

Quick Connects: .020 x .187 See pages 104-115 for terminal block accessories
.41 [10.4] "A" "B" .30 [7.6] .14 [3.6] .56 [14.3] .38 [9.5] .31 [7.9] .25 [6.3] .16 [4.0]

#5-40 x .25 [6.3] BD HD SCREW

.22 [5.5]

96

Datasheets available at marathonsp.com

Single Row Terminal Blocks


Kulka 699/899 GP Series 300 Volts AC/DC (Class B)
699 Series only

150 Volts AC/DC (Class C)


699 and 899 Series

699 GP 06

Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip Required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #6-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-23 Poles 7/16 Centers
Kulka Catalog # 699 GP 01 699 GP 02 699 GP 03 699 GP 04 699 GP 05 699 GP 06 699 GP 07 699 GP 08 699 GP 09 699 GP 10 699 GP 11 699 GP 12 699 GP 13 699 GP 14 699 GP 15 699 GP 16 699 GP 17 699 GP 18 699 GP 19 699 GP 20 699 GP 21 699 GP 22 699 GP 23
mm = dim X 25.4 For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Wire Range With Wire Binding Screw #14 - #16 AWG 20 Amps 899 Series (Riveted KTs) - shown at right, see page 104 for KTs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

899 Series

Single Row Terminal Blocks

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 A 1.19 1.63 2.06 2.50 2.94 3.38 3.81 4.25 4.69 5.12 5.56 6.00 6.44 6.87 7.31 7.75 8.19 8.62 9.06 9.50 9.94 10.37 10.81 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT46 KT47 KT48 KT52 KT53 KT54 3/4 ST Z J 601 601 RJ(S) 2102 2104 2120 2121 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Lug over the Side (.437) Line to Line Jumper Multiple Position Jumper Stud Feed Thru Solder Solder Pin Solder Pin Phil-Slot Brass Screw

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 Consult C/S See page 107 See page 107 See page 109 See page 109 See page 109 See page 109 Consult C/S

Quick Connects: .032 x .250 See pages 104-115 for terminal block accessories
.50 "A" "B" [12.7] .31 [7.9] .22 [5.5]

.33 [8.4]

.16 [4.0]

.69 [17.4] .50 [12.7] #6-32 X .25 [6.4] BD HD SCREW

.44 [11.1] .18 [4.4]

.38 [9.5]

.25 [6.4]

Datasheets available at marathonsp.com

97

Single Row Terminal Blocks


Kulka 812/912 GP Series
812 Series only 912 Series only

600 Volts AC/DC (Classes B/C)


812 GP 06

300 Volts AC/DC (Class C)


Specifications:
Base, Phenolic, 150oC (UL RTI) Open Back Design (Insulator Strip Required for Voltage Rating - see page 112) JJ (GDI-30F) Material Available Screws, #8-32 Binder Head, Phil-Slot, Steel Terminals, Plated Brass 1-18 Poles 9/16 Centers

Single Row Terminal Blocks

Wire Range With Wire Binding Screw #12 - #14 AWG 30 Amps 912 Series (Riveted KTs) - shown at right, see page 104 for KTs UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant

912 Series

Kulka Catalog # 812 GP 01 812 GP 02 812 GP 03 812 GP 04 812 GP 05 812 GP 06 812 GP 07 812 GP 08 812 GP 09 812 GP 10 812 GP 11 812 GP 12 812 GP 13 812 GP 14 812 GP 15 812 GP 16 812 GP 17 812 GP 18
mm = dim X 25.4

Dimensions # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A 1.53 2.09 2.66 3.22 3.78 4.34 4.91 5.47 6.03 6.59 7.16 7.72 8.28 8.84 9.41 9.97 10.53 11.09 B 1.13 1.69 2.25 2.81 3.38 3.94 4.50 5.06 5.63 6.19 6.75 7.31 7.88 8.44 9.00 9.56 10.13 10.69

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT73 KT74 KT75 KT79 KT80 KT81 3/4 ST Z J 602 2202 2204 PSB

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Lug over the Side (.641) Line to Line Jumper Stud Feed Thru Solder Phil-Slot Brass Screw

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 Consult C/S See page 107 See page 109 See page 109 Consult C/S

Quick Connects: .032 x .250 See pages 104-115 for terminal block accessories
.72 [18.2] "A" "B" .41 [10.5] .47 [11.9] .56 [14.3] .30 [7.6] .21 [5.2] .41 [10.3] .28 [7.1]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.75 [19.1]

#8-32 X .31 [7.9] BD HD SCREW

.21 [5.4]

98

Datasheets available at marathonsp.com

Single Row Terminal Blocks


Kulka 1690 GP Series 300 Volts AC/DC (Class B) 150 Volts AC/DC (Class C)
Specifications:
Base, Phenolic, 150oC (UL RTI) Screws, #6-32 Binder Head, Phil-Slot, Brass Terminals, Plated Brass Two speed-nuts supplied per part 7/16 Centers Wire Range #14 Max. - 20 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant
TERMINAL BLOCK SERIES 1694 GP 1697 GP 1695 GP 1698 GP 1696 GP 1699 GP Dimensions A 1.22 1.66 2.09 2.53 2.97 3.41 3.84 4.28 4.72 5.16 5.59 6.03 6.47 6.91 7.34 7.78 8.22 8.66 9.09 9.53 9.97 10.41 10.84 --B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50 --Dimensions A 0.53 0.97 1.41 1.84 2.28 2.72 3.16 3.59 4.03 4.47 4.91 5.34 5.78 6.22 6.66 7.09 7.53 7.97 8.41 8.84 9.28 9.72 10.16 --B -0.44 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 ---

Top to bottom: 1694 GP 04 PSB, 1691 GP 06 PSB

Single Row Terminal Blocks

1691 GP 1692 GP 1693 GP # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Dimensions A 0.34 0.78 1.22 1.66 2.09 2.53 2.97 3.41 3.84 4.28 4.72 5.16 5.59 6.03 6.47 6.91 7.34 7.78 8.22 8.66 9.09 9.53 9.97 10.41 10.84 B

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

-0.44 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50

CATALOG # MSP KULKA KT46 KT47 KT48 KT52 KT53 KT54 3/4 ST J 601 601 RJ(S)

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Line to Line Jumper Multiple Position Jumper

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 See page 107 See page 107

Quick Connects: .032 x .250 See pages 104-115 for terminal block accessories

mm = dim X 25.4

Include PSB after part # when ordering (169X GP XX PSB)


See page 100 for 1690 Series Terminal block dimensions.

Datasheets available at marathonsp.com

99

Single Row Terminal Blocks


Kulka 1690 GP Series
(cont.)
A B .44 [11.1] .34 [8.6] .50 [12.7] PARTIAL .63 [15.9] .34 [8.7] .03 [.8] END VIEW SPEED NUT .17 [4.3] PANEL

TERMINAL BLOCK SERIES 1691 GP / 1692 GP / 1693 GP


1691 GP Series Solder terminal K = .52 [13.10]; W = .06 [1.59] Kliptite terminal Solder terminal K = .58 [14.68]; W = .13 [3.18]
"K" "W"

NO. 6-32 x 3/16 LG.BIND.HD.SCR. .28 [7.1] .66 [16.8] .11 [2.9] .05 [1.3] "KLIPTITE" TERMINAL .03 [.8] .31 [7.8] .30 [7.5] .54 [13.6]

1692 GP Series 1693 GP Series

Single Row Terminal Blocks

SOLDER TERMINAL

A B .44 [11.1] .17 [4.3]

PANEL

TERMINAL BLOCK SERIES 1694 GP / 1695 GP / 1696 GP


1694 GP Series Solder terminal K = .52 [13.10]; W = .06 [1.59] Kliptite terminal Solder terminal K = .58 [14.68]; W = .13 [3.18]
.34 [8.7]

.18 [4.4]

.34 [8.6]

.50 [12.7] .63 [15.9] NO. 6-32 x 3/16 LG.BIND.HD.SCR.

PARTIAL END VIEW SPEED NUT .54 [13.6]

1695 GP Series 1696 GP Series

.03 [.8]

.28 [7.1] .66 [16.8]

.30 [7.5]

"K" "W" SOLDER TERMINAL "KLIPTITE" TERMINAL .11 [2.9] .05 [1.3]

.03 [.8] .31 [7.8]

A B .27 [6.8]

PANEL

TERMINAL BLOCK SERIES 1697 GP / 1698 GP / 1699 GP


1697 GP Series Solder terminal K = .52 [13.10]; W = .06 [1.59] Kliptite terminal Solder terminal K = .58 [14.68]; W = .13 [3.18]

.44 [11.1] .34 [8.6] .50 [12.7] .63 [15.9] .34 [8.7] .03 [.8] NO. 6-32 x 3/16 LG.BIND.HD.SCR. .28 [7.1] .66 [16.8] "W" .05 [1.3] "KLIPTITE" TERMINAL .11 [2.9] .03 [.8] .31 [7.8] .30 [7.5]

PARTIAL END VIEW SPEED NUT .54 [13.6]

1698 GP Series 1699 GP Series

"K"

SOLDER TERMINAL

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

100

Datasheets available at marathonsp.com

Single Row Terminal Blocks


Kulka 2590 GP Series 300 Volts AC/DC (Class B) 150 Volts AC/DC (Class C)
Specifications:
Base, Phenolic, 150oC (UL RTI) Screws, #6-32 Binder Head, Slotted, Brass Terminals, Plated Brass 3/8 Centers Wire Range #16 Max. - 15 Amps The Suitability Of These Devices For Greater Currents Shall Be Determined In the End-Use Application UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant
TERMINAL BLOCK SERIES 2591A GP 2597A GP 2593A GP 2599A GP # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Dimensions A 1.19 1.56 1.94 2.31 2.69 3.06 3.44 3.81 4.19 4.56 4.94 5.31 5.69 6.06 6.44 6.81 7.19 7.56 7.94 8.31 8.69 9.06 9.44 --B 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63 9.00 --Dimensions A 0.44 0.81 1.19 1.56 1.94 2.31 2.69 3.06 3.44 3.81 4.19 4.56 4.94 5.31 5.69 6.06 6.44 6.81 7.19 7.56 7.94 8.31 8.69 9.06 9.44 B -0.38 0.75 1.13 1.50 1.88 2.25 2.63 3.00 3.38 3.75 4.13 4.50 4.88 5.25 5.63 6.00 6.38 6.75 7.13 7.50 7.88 8.25 8.63 9.00
.23 [5.7] A B .38 [9.5] .56 [14.2] .20 [5.2] .39 [9.9] .03 [.8] 2597A "W"= .062 W 2599A "W"= .093 .30 [7.6] NO.6-32 x 3/16 LG.BIND.HD.SCR.

2591A GP 04 PSB

2599A GP 04 PSB

Series 2591A GP / 2593A GP


A .23 [5.7] B .38 [9.5] .20 [5.2] .39 [9.9] .56 [14.2] .15 [3.7] .03 [.8] 2591A "W"= .062 2593A "W"= .093 W .56 [14.2] .30 [7.6] NO.6-32 x 3/16 LG.BIND.HD.SCR.

Single Row Terminal Blocks

Series 2597A GP / 2599A GP

.56 [14.2]

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

mm = dim X 25.4

CATALOG # MSP KULKA KT28 KT29 KT30 KT34 KT35 KT36 3/4 ST Y Z J 600 600 RJ(S) 3000 2591A PC 2593A PC 2597A PC 2599A PC

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Lug Over the Side (.359) Lug Over the Side (.172) Line to Line Jumper Multiple Position Jumper Wire Wrap Lug (.641) Printed Circuit (.20 x .062) Printed Circuit (.20 x .093) Printed Circuit (.20 x .062) Printed Circuit (.20 x .093)

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 See page 106 See page 106 See page 107 See page 107 Consult C/S Consult C/S Consult C/S Consult C/S Consult C/S

Quick Connects: .032 x .250 For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com See pages 104-115 for terminal block accessories

Datasheets available at marathonsp.com

101

Single Row Terminal Blocks


Kulka 2690 GP Series 300 Volts AC/DC (Class B) 150 Volts AC/DC (Class C)
Specifications:
Base, Phenolic, 150oC (UL RTI) Screws, #6-32 Binder Head, Slotted or #8-32 Binder Head, Slotted,Brass Terminals, Plated Brass 7/16 Centers Wire Range #14-16 AWG - 20 Amps UL Recognized File No. XCFR2.E47811 CSA Certified File No. LR19766 RoHS Compliant
TERMINAL BLOCK SERIES 2694 GP / 2694A GP 2695 GP / 2695A GP 2696 GP / 2696A GP # of poles 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Dimensions A 1.41 1.84 2.28 2.72 3.16 3.59 4.03 4.47 4.91 5.34 5.78 6.22 6.66 7.09 7.53 7.97 8.41 8.84 9.28 9.72 10.16 10.59 11.03 B 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50 2697 GP / 2697A GP 2698 GP / 2698A GP 2699 GP / 2699A GP Dimensions A 0.53 0.97 1.41 1.84 2.28 2.72 3.16 3.59 4.03 4.47 4.91 5.34 5.78 6.22 6.66 7.09 7.53 7.97 8.41 8.84 9.28 9.72 10.16 10.59 11.03 B -0.44 0.88 1.31 1.75 2.19 2.63 3.06 3.50 3.94 4.38 4.81 5.25 5.69 6.13 6.56 7.00 7.44 7.88 8.31 8.75 9.19 9.63 10.06 10.50

Top to bottom: 2695A GP 04, 2699A GP 04

Single Row Terminal Blocks

Hardware Options:
(Hardware options may affect ratings - consult Customer Service)

CATALOG # MSP KULKA KT28 KT29 KT30 KT34 KT35 KT36 KT46 KT47 KT48 KT52 KT53 KT54 3/4 ST Y Z J 601 601 RJ(S)

PRODUCT DESCRIPTION Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Full Quick Connect (0o Flat) Full Quick Connect (45o Bend) Full Quick Connect (90o Bend) Half Quick Connect (0o Flat) Half Quick Connect (45o Bend) Half Quick Connect (90o Bend) Half Solder Lug Over the Side (.609) Lug Over the Side (.344) Line to Line Jumper Multiple Position Jumper

PAGE REFERENCE See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 104 See page 106 See page 106 See page 106 See page 107 See page 107

Quick Connects (KT28-36): .020 x .187 - Quick Connects (KT46-54): .032 x .250 See pages 104-115 for terminal block accessories

mm = dim X 25.4

See page 103 for 2690 Series Terminal block dimensions.

102

Datasheets available at marathonsp.com

Single Row Terminal Blocks


Kulka 2690 GP Series
(cont.)

TERMINAL BLOCK SERIES: 2694 GP / 2694A GP / 2695 GP 2695A GP / 2696 GP / 2696A GP


DEFINITION 2694 GP 2695 GP 2696 GP BARRIER ENDS: #6-32 Brass Screw, Printed Circuit Width = .062 #6-32 Brass Screw, Solder Turret (not shown) #6-32 Brass Screw, Printed Circuit Width = .093 2694A GP #8-32 Brass Screw, Printed Circuit Width = .062 2695A GP #8-32 Brass Screw, Solder Turret (not shown) 2696A GP #8-32 Brass Screw, Printed Circuit Width = .093
A B .44 [11.1] .56 [14.2] .20 [5.2]

.27 [6.8] "W" WIDTH OF TERMINAL .17 [4.3]

Single Row Terminal Blocks

2695 GP 04
.031 TERMINAL THICKNESS PARTIAL BOTTOM VIEW

.64 [16.3]

.34 [8.6]

3/16 LG.BIND.HD.SCR.

2695A GP 04

.38 [9.7]

2694 & 2694A "W"=.062 2696 & 2696A "W"=.093

TERMINAL BLOCK SERIES: 2697 GP / 2698 GP / 2699 GP 2697A GP / 2698A GP / 2699A GP


DEFINITION 2697 GP 2698 GP 2699 GP BARRIER ENDS: #6-32 Brass Screw, Printed Circuit Width = .062 #6-32 Brass Screw, Solder Turret (not shown) #6-32 Brass Screw, Printed Circuit Width = .093 2697A GP #8-32 Brass Screw, Printed Circuit Width = .062 2698A GP #8-32 Brass Screw, Solder Turret (not shown) 2699A GP #8-32 Brass Screw, Printed Circuit Width = .093

.27 [6.8]

B .56 [14.2] .44 [11.1] .20 [5.2]

2699 GP 04

"W" WIDTH OF TERMINAL

.64 [16.3]

.031 TERMINAL THICKNESS

.34 [8.6]

3/16 LG.BIND.HD.SCR.

2699A GP 04

PARTIAL BOTTOM VIEW

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.38 [9.7]

2697 & 2697A "W"=.062 2699 & 2699A "W"=.093

Datasheets available at marathonsp.com

103

Terminal Block Accessories


Kliptite (Quick Connect) - Single Row
Specifications:
Kliptite (Quick Connect) accept standard female wire terminals. These Klipties are ideal for applications that require a positive, yet quick disconnect termination. Kliptites are assembled to the block with screws or, in some applications, riveted to the block. Kliptites are available in 0o, 45o or 90o bends; one side or two side. Material: Brass; Finish: Tin

(2) 0o tabs

(2) 45o tabs

(2) 90o tabs

(1) 0o tab

(1) 45o tab

(1) 90o tab

Screw Construction 411 Series 599 Series 699 Series 812 Series 1690 Series1 2590 Series2 2690 Series3

Rivet Construction 799 Series 899 Series 912 Series

Tab Width 0.110 0.187 0.250 0.250 0.250 0.187 0.250

Tab Thickness 0.020 0.020 0.032 0.032 0.032 0.020 0.032 KT10 KT28 KT46 KT73 KT46 KT28 KT46 KT11 KT29 KT47 KT74 KT47 KT29 KT47 KT12 KT30 KT48 KT75 KT48 KT30 KT48 KT16 KT34 KT52 KT79 KT52 KT34 KT52 KT17 KT35 KT53 KT80 KT53 KT35 KT53 KT18 KT36 KT54 KT81 KT54 KT36 KT54

Terminal Block Accessories

1) 1690 Series insulated feed-thru blocks use the 699 Series Kliptites 2) 2590 Series use the 599 Series Kliptites 3) 2690 Series PC block use the 699 Kliptites

TWO SIDE TABS KT10


.10 [2.5] 1.03 [26.2] .02 [.5]

ONE SIDE TABS KT12


.34 [8.7]

KT11

.84 [21.4] .34 [8.6]


90

KT16
.59 [15.1]
.25 [6.4]

KT17
.25 [6.4]

KT18

.26 [6.6]

45

90

.18 [4.6]

.11 [2.8]

45

.35 [8.9]

KT28
1.09 [27.8] .19 [4.8] .28 [7.1]

KT29
.94 [23.9] .38 [9.5] 45
.38 [9.5]

KT30

KT34
.75 [19.1]
.38 [9.6]

KT35
.38 [9.6]

KT36

45

90

.145 [3.67]

.02 [.5]

.26 [6.7]

.38 [9.6]

KT46
.25 [6.4] 1.48 [37.6] .31 [7.9]
.39 [10.0] 45

KT47
1.22 [31.0]

KT48
.35 [8.9] .56 [14.2]
.41 [10.4]

KT52
.90 [22.9]

KT53

KT54

.153 [3.88]

.031 [.79]

90

.34 [8.7]

45

.34 [8.6]

90

KT73
1.22 [30.9] .171 [4.34] .030 [.76] .41 .23 [10.3] [5.9]

KT74
1.00 [25.4] .38 [9.7] 45

KT75
.38 [9.7] 90
.32 [8.1]

KT79
.82 [20.8]
.41 [10.3]

KT80
.41 [10.3]
45

KT81

.44 [11.3]

90

104

Datasheets available at marathonsp.com

Terminal Block Accessories


Kliptite (Quick Connect) - Double Row
(2) 0o tabs (2) 45o tabs (2) 90o tabs (1) 0o tab (1) 45o tab (1) 90o tab

Screw Construction 100 Series4 200 Series5 300 Series6 400 Series 600 Series 600A Series 601 Series 602 Series 603 Series 621 RZ Series5 670A GP Series4 670A RZ Series4 671 GP Series5 671 RZ Series5 672 GP Series6 672 RZ Series6

Rivet Construction

Tab Width 0.187 0.250 0.250 0.250 0.187 0.187 0.250 0.250 0.250 0.250 0.187 0.187 0.250 0.250 0.250 0.250

Tab Thickness 0.020 0.032 0.032 0.032 0.020 0.020 0.032 0.032 0.032 0.032 0.020 0.020 0.032 0.032 0.032 0.032 KT19 KT37 KT55 KT67 KT19 KT19 KT37 KT55 KT67 KT37 KT19 KT19 KT37 KT37 KT55 KT55 KT20 KT38 KT56 KT68 KT20 KT20 KT38 KT56 KT68 KT38 KT20 KT20 KT38 KT38 KT56 KT56 KT21 KT39 KT57 KT69 KT21 KT21 KT39 KT57 KT69 KT39 KT21 KT21 KT39 KT39 KT57 KT57 KT25 KT43 KT61 KT64 KT25 KT25 KT43 KT61 KT64 KT43 KT25 KT25 KT43 KT43 KT61 KT61 KT26 KT44 KT62 KT65 KT26 KT26 KT44 KT62 KT65 KT44 KT26 KT26 KT44 KT44 KT62 KT62 KT27 KT45 KT63 KT66 KT27 KT27 KT45 KT63 KT66 KT45 KT27 KT27 KT45 KT45 KT63 KT63

800A Series 801 Series 802 Series

Terminal Block Accessories

4) 100, 670A GP, 670A RZ Series use the 600, 600A Series Kliptites 5) 200, 671 GP, 671 RZ, 621 RZ Series use the 601 Series Kliptites 6) 300, 672 GP, 672 RZ Series use the 602 Series Kliptites

MSP Catalog Designations: 2-SIDE TABS: F1 (0o), F2 (45o), F3 (90o) 1-SIDE TABS: HF1 (0o), HF2 (45o), HF3 (90o)

TWO SIDE TABS KT19 (F1)


1.38 [34.9] .31 [7.9]
.02

ONE SIDE TABS KT21 (F3)


.69 [17.5] 90
45

KT20 (F2)
.69 [17.5] 1.33 [33.7]

KT25 (HF1)
.94 [23.8]
.59

KT26 (HF2)

KT27 (HF3)
.59 [15.0]

[15.1]

45

[.5]

90

.19 [4.8]

.14 [3.6]

.28 [7.2]

.25 [6.4]

.36 [9.1]

KT37 (F1)
1.84 [46.8] .42 [10.7] .18 [4.6] .33 [8.4]

KT38 (F2)
1.57 [39.9] .83 [21.0]

KT39 (F3)
.84 [21.4]

KT43 (HF1)
1.30 [32.9]

KT44 (HF2)

KT45 (HF3)
.79 [20.1]

.79 [20.1]

90
45

45

90

.25 [6.4]

.032 [.81]

.52 [13.1]

.37 [9.5]

KT55 (F1)
1.99 [50.5] .50 [12.7] .188 [4.8] .39 [10.0]
.41 [10.4]

KT56 (F2)
1.68 [42.7] .97 [24.7]

KT57 (F3)
.91 [23.1] 90
45

KT61 (HF1)
1.42 [36.0]

KT62 (HF2)
.92 [23.4] 45

KT63 (HF3)
.88 [22.4] 90

.56 [14.1]

.25 [6.4]

.032 [.81]

KT67 (F1)
1.89 [48.0] .63 [15.9] .203 THRU HOLES TYP. 3 PLCS.

KT68 (F2)
1.69 [43.0] 1.08 [27.4]

KT69 (F3)
1.08 [27.4]

KT64 (HF1)
1.44 [36.5]

KT65 (HF2)

KT66 (HF3)
1.02 [26.0]

90
.032 [.81] .41 [10.3] .25 [6.4]

1.03 [26.2]

45

90

45 .31 [7.9]

.43 [10.9]

Datasheets available at marathonsp.com

105

Terminal Block Accessories


Solder Terminal Lugs ST and 3/4 ST Types
FIGURE 411 ST 411 3/4ST 599 3/4ST 600 ST 600 3/4ST 601 ST 601 3/4ST 602 ST 602 3/4ST 699 3/4ST 812 3/4ST
mm = dim x 25.4

ALSO USED ON

SEE FIGURE #1 SEE FIGURE #1A FIG 2 FIG 3 FIG 3A FIG 3 FIG 3A FIG 3 FIG 3A FIG 2 FIG 2 0.56 1.22 0.92 1.58 1.17 1.85 1.37 0.70 0.88 -0.75 -0.94 -1.06 ----0.69 -0.84 -0.94 ----0.31 0.31 0.42 0.42 0.50 0.50 --0.28 0.28 0.28 0.31 0.31 0.41 0.41 0.31 0.41 0.16 0.16 0.16 0.21 0.21 0.28 0.28 0.21 0.28 0.06 0.06 0.06 0.06 0.06 0.09 0.09 0.06 0.09 0.16 0.16 0.16 0.21 0.21 0.28 0.28 0.21 0.28 0.032 0.032 0.032 0.036 0.036 0.036 0.036 0.032 0.037 0.144 0.144 0.144 0.148 0.148 0.177 0.177 0.146 0.177 0.093 0.093 0.093 0.125 0.125 0.125 0.125 0.125 0.125 0.11 -0.15 -0.17 -0.20 0.13 0.19 ---------2590, 2590A 600A, 670A GP 200HB, 621 RZ 672 GP 1690, 2690

MSP Catalog Designations: ST = S

3/4ST = HS

To ensure solderability, use within six (6) months.

Terminal Block Accessories

FIGURE 1
1.03 [26.2] .66 [16.7] .12 [3.2] .18 [4.7]

FIGURE 1A
.66 [16.8] .14 REF. [3.7]

FIGURE 2
H M-DIA. A E G F J
N-DIA. 2-HOLES T-DIA. HOLE

FIGURE 3
A B C J E D G F H M-DIA. 2-HOLES

FIGURE 3A

A R REF.

HOLE

.10 [2.4] .06 [1.6] 2 HOLES

.02

N-DIA. 2-HOLES R REF.

.06 [1.6] .02 [.5]

[.5]

Y, YSY and Z Types


FIGURE 599Z, 600Y 600YSY 600Z 699Z, 601Y 601YSY 602Y 812Z, 602YSY 602Z 603Y 672 YSY
mm = dim x 25.4

(Material: Brass Finish Electro-Tin Plated)


D E F H NA NA NA NA NA NA J 0.144 0.144 0.160 0.148 0.148 0.177 0.177 0.177 NA M NA NA 0.143 NA NA NA NA NA 0.14 L (see detail R) 599Z=0.31, 600Y=0.31 0.50 0.62 699Z=0.42, 601Y=0.42 0.69 0.49 812Z=0.64, 602YSY=0.67 0.60 0.60 0.56 300 series
To ensure solderability, use within six (6) months.

A 0.28 0.28 0.28 0.31 0.31 0.43 0.40 0.40 0.42

B 0.48 0.48 0.73 0.63 0.63 0.75 0.70 1.09 0.70

ALSO USED ON 670A RZ 670A RZ 670A RZ

FIG 6 FIG 6 FIG 7 FIG 4 FIG 5 FIG 4 FIG 5 FIG 8 FIG 9 FIG 7

0.33 0.085 0.63 0.036 0.33 0.085 0.82 0.036 0.44 0.099 0.80 0.036 0.44 0.099 1.07 0.040 0.52 0.125 0.95 0.040 0.52 0.125 1.13 0.040

0.25 0.140 0.94 0.036 0.31

0.38 0.203 1.06 0.040 0.50 0.27 0.08 1.02 0.040 0.25

NOTE: For factory assembly only onto 603 Terminal Boards


MSP Catalog Designations: Y = L YSY = LSL

FIGURE 4
B C A F
A

FIGURE 7
E
B H C E F
.91 [23.0] .66 [16.7]

FIGURE 9
1.11 [28.2] .15 [3.7] .062 [1.57]

DETAIL (R)

"L".03 LENGTH UNDER TERM BLOCK.

D J HOLE

D J HOLE M HOLE
.45 [11.4] .16 [4.1] .31 [7.9] .14 [3.5]

FIGURE 5

FIGURE 6

FIGURE 8
J DIA. HOLES

"L".03

Figures 5 & 6 same as Figure 4 except as shown

Same as Figure 7 except as shown

106

Datasheets available at marathonsp.com

Terminal Block Accessories


J & JS Jumpers
Catalog # J 410/J 411 J 600 J 601 J 602 J 603 J 604 J 605 J 621 JS 600 JS 601 JS 602 A 0.41 0.62 0.71 0.91 1.13 1.38 1.75 0.69 0.62 0.71 0.91 B 0.25 0.38 0.45 0.56 0.69 0.88 1.13 0.44 0.38 0.45 0.56 C 0.19 0.25 0.31 0.37 0.43 0.50 0.62 0.30 0.25 0.31 0.37 D 0.09 0.12 0.15 0.18 0.21 0.25 0.31 0.17 0.12 0.15 0.18 E 0.10 0.16 0.19 0.27 0.25 0.35 0.39 0.38 0.16 0.19 0.27 F 0.04 0.04 0.06 0.08 0.12 0.15 0.24 0.07 0.04 0.06 0.08 G 0.010 0.015 0.015 0.015 0.031 0.035 0.035 0.015 0.015 0.015 0.015 H 0.094 0.156 0.166 0.190 0.201 0.234 0.266 0.141 0.156 0.166 0.190 J 0.08 0.08 0.11 0.16 0.24 0.32 0.54 0.11 0.08 0.11 0.16 K NA NA NA NA NA NA NA 0.14 0.16 0.17 0.14
MSP Catalog Designations: J 600 = LL 100 J 601 = LL 200 J 602 = LL 300 J 603 = LL 400 Material: Brass Finish: Nickel Plate
A B

J Type Jumper

D H

E J G

JS Type Jumper
mm = dim X 25.4
(per 55164/28B)
K

NOTE 1: These parts are not necessarilty supplied flat. The functioning of the part, however, will not be interferred.

NOTE 2: All dimensions are applicable after the bus (jumper) is torqued down into the associate terminal board.
.23 [5.9] .17 [4.3] .72 [18.3] .12 [3.0] .14 [3.6] .52 [13.2] .14 [3.6] .032 [.81] .15 [3.8] .28 [7.1] .16 [4.0] .031 [.79]

RJ Type Jumpers

Terminal Block Accessories

.65 [16.5]

Material: Brass Finish: Nickel Plate

.38 [9.5]

.15 [3.8]

.44 [11.1]

.16 [4.0]

600 RJ Max # of sections = 24


Note: 670A RZ, 599 Series, use 600 RJ

601 RJ Max # of sections = 24


.28 [7.1] .031 [.79] .16 [4.0]

RJS Type Jumpers

.28 [7.1] .25 [6.4] .14 [3.6] .45 [11.4] .14 [3.6] .374 [9.50]

.08 [2.0] .031 [.79] .71 [18.1]

.26 [6.6]

.56 [14.2] .14 [3.6] .437 [11.10] R .078 [1.98]

R .07 [1.8]

.18 [4.6]

.19 [4.9]

Material: Brass Finish: Nickel Plate

600 RJS Max # of sections = 24


Note: 670A RZ, 599 Series, use 600 RJ

601 RJS Max # of sections = 24

Wire Clamp

PHIL-SLOT L

A A

SCREW THREAD
NOTE: Termi-lox washer or equal

Catalog # Material Finish Screw Thread 3786 8-32 UNC Steel Nickel 3765 6-32 UNC 3780 8-32 UNC Brass Nickel 3760 6-32 UNC 3860 Brass Nickel 6-32 UNC 3865 Steel Nickel 6-32 UNC

L 0.38 0.31 0.38 0.31 0.30 0.30

A 0.41 0.33 0.41 0.33 0.29 0.29

mm = dim X 25.4

Straddle Plate
A B D C F E

Catalog # SPB 600 SPB 601 SPB 602 SPB 603 SPB 604 SPB 605

A 0.56 0.71 0.87 1.03 1.21 1.46

B 0.31 0.42 0.50 0.62 0.75 0.87

C 0.30 0.30 0.40 0.45 0.54 0.63

D 0.032 0.031 0.032 0.063 0.087 0.116

E F Material Finish 0.144 N/A Brass Tin 0.148 N/A Brass Nickel 0.189 N/A Brass Nickel 0.190 0.143 Brass Tin 0.187 0.138 Brass Tin 0.220 0.138 Brass Nickel
mm = dim X 25.4

Datasheets available at marathonsp.com

107

Terminal Block Accessories


Kulka Fanning Strips
Terminals, Brass, Tin Plated Material: XP = Phenolic, Black GME = Glass Cloth Melamine Per MIL-M-14 Light Brown Term

649 Series
For 410 and 411 Series Terminal Blocks Available in XP Phenolic Only
# of Term. 2 3 4 5 6 7 8
649A Series 649 Series

A 0.250 0.500 0.750 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750

B 0.562 0.812 1.062 1.312 1.562 1.812 2.062 2.312 2.562 2.812 3.062

# of Term. 13 14 15 16 17 18 19 20 21 22

A 3.000 3.250 3.500 3.750 4.000 4.250 4.500 4.750 5.000 5.250

B 3.312 3.562 3.812 4.062 4.312 4.562 4.812 5.062 5.312 5.562

Terminal Block Accessories

9 10 11 12

650/651/652 Series
650 Series for 599, 600, and 670A RZ Series Terminal Blocks 651 Series for 601 and 699 Series Terminal Blocks 652 Series for 602 and 812 Series Terminal Blocks
SERIES W 650/650A .50 651/651A .63 652/652A .63

SERIES C # of Term. 2 3 4 5 6 7 8 9 10 11 12 13

650 / 650A 3/8 (.375) A .375 .750 1.125 1.500 1.875 2.250 2.265 3.000 3.375 3.750 4.125 4.500 4.875 5.250 5.625 6.000 6.375 6.750 7.125 7.500 7.875 ----B 1.435 1.810 2.185 2.560 2.935 3.310 3.685 4.060 4.435 4.810 5.165 5.560 5.935 6.310 6.685 7.060 7.435 7.810 8.186 8.560 8.935 -----

651 / 651A 7/16 (.4375) A .437 .875 1.312 1.750 2.187 2.625 3.062 3.500 3.937 4.375 4.812 5.250 5.687 6.125 6.562 7.000 7.437 7.875 8.312 8.750 9.187 9.625 ---B 1.497 1.935 2.372 2.610 3.247 3.685 4.122 4.560 4.997 5.435 5.872 6.310 6.747 7.185 7.622 8.060 8.497 8.935 9.372 9.810

652 / 652A 9/16 (.5625) A .562 1.125 1.687 2.250 2.812 3.375 3.937 4.500 5.062 5.625 6.187 6.750 7.312 7.875 8.437 9.000 9.562 B 1.622 2.185 2.747 3.310 3.872 4.435 4.997 5.560 6.122 6.685 7.247 7.810 8.372 8.935 9.497 10.060 10.622

(L) LEFT

(R) RIGHT

Ordering Code
For convenience and accuracy in ordering, please specify catalog numbers as shown: For Marking Strips, use an MS prefix on the series For Insulator Strips, use an IS prefix on the series
Series 649 Mat. Code XP Angle A L # of Term 5

14 15 16 17 18 19 20 21 22 23 24 25 26

10.125 11.185 10.687 11.747 11.250 12.310

10.247 11.812 12.672 10.685 12.375 13.435 ---12.937 13.997 13.500 14.560 14.062 15.122

108

Datasheets available at marathonsp.com

Terminal Block Accessories


Kulka Stud and Turret Terminal Blocks
Threaded Stud
CONNECTOR NUT STRADDLE PLATE (SEE NOTE #1) B

Catalog #

Figure

FIG.1
6-32NC-2

FIG.2

FIG.3
8-32NC-2

C (THREAD)

.38 [9.5] .25 [6.4]

.53 [13.5]

599 GP 2002 XX 600A GP 2002 XX 601 GP 2102 XX 602 GP 2202 XX 603 GP 2302 XX 604 GP 2402 XX 605 GP 2502 XX 699 GP 2102 XX 812 GP 2202 XX
NOTE 1: NOTE 2:

FIG FIG FIG FIG FIG FIG FIG FIG FIG

3 2 2 2 1 1 1 3 3

0.38 0.38 0.44 0.56 0.69 0.88 1.13 0.44 0.56

0.34 0.38 0.44 0.50 0.50 0.44 0.75 0.44 0.50

6-32 NC 6-32 NC 6-32 NC 8-32 NC 10-32 NF 10-32 NF 1/4-28 NF 6-32 NC 8-32 NC

.23 [5.9]

Standard with block, but packed separately 604 and 605 nuts are part of the assembly. Additional nuts (one per stud) are supplied in bulk.

XX = # of terminals

Screw Terminal with Feed-Thru Solder Terminal


CONNECTORS ASSEMBLED ON 600-2004 AND 410-1904 ONLY C (SCREW) B

Terminal Block Accessories

Catalog #

Figure

FIG.1

FIG.2

411 599 600 601 699 812

GP GP GP GP GP GP

1904 2004 2004 2104 2104 2204

XX XX XX XX XX XX

FIG FIG FIG FIG FIG FIG

2 2 1 1 2 2

0.25 0.38 0.38 0.44 0.44 0.56

0.28 0.31 0.31 0.38 0.38 0.44

2-56 5-40 5-40 6-32 6-32 8-32

NC NC NC NC NC NC

X X X X X X

.19 .25 .25 .25 .25 .25

0.11 0.14 0.14 0.13 0.13 0.14

To ensure solderability, use within six (6) months.

XX = # of terminals

Screw Terminal with Solder Pin for Printed Circuit Board Connection
B
Catalog # A B C D E

599 599 699 699

GP GP GP GP

2020 2021 2120 2121

XX XX XX XX

0.38 0.38 0.44 0.44

0.13 0.13 0.19 0.20

0.09 0.09 0.09 0.06

0.09 0.03 0.04 0.04

5-40 5-40 6-32 6-32

NC NC NC NC

X X X X

.19 .19 .25 .25

To ensure solderability, use within six (6) months.

XX = # of terminals

E (SCREW)

Individual Screw Terminals


A

Catalog #

601 GP 2108 XX
C (SCREW)

0.44

0.09

6-32 NC X .25
XX = # of terminals

Datasheets available at marathonsp.com

109

Terminal Block Accessories


Double Row - Top Mounted Covers/Marking Strips
Specifications:
White Vinyl Material, 0.03 thick Two Nylon Spring Clips for Mounting Provided Marking Strips: Printed on Center Line with Letters or Numbers for Circuit Identification Covers: Printed on Top, Bottom or Center Line with Letters or Numbers for Circuit Identification
Series 1 Series 2 Series 3 Printing Character Size is 1/8 Inch Unless Otherwise Specified, the Marking goes down the Center of the Cover for Print Styles 01A, 01B, 01C, 01D Marking goes down the 2 Sides of the Cover for Print Styles 07A, 07B, 07C, 07D

COVER
.31 (7.9) .31 (7.9) .14 (3.6) 1.31 (33.3)

100/670A GP, 200/671 GP, 601 GP, 300/672 GP 600 GP, 600A GP, 670A RZ 621 RZ, 671 RZ 602 GP, 672 RZ Number of Terminals 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 A 0.91 1.29 1.66 2.04 2.41 2.79 3.16 3.56 3.91 4.29 4.66 5.04 5.41 5.79 6.16 6.54 6.91 7.29 7.66 8.04 8.41 8.79 9.16 9.54 9.91 10.29 10.66 11.04 11.41 11.79 12.16 12.54 12.91 13.29 13.66 14.04 B 0.55 0.93 1.30 1.68 2.05 2.43 2.80 3.20 3.55 3.93 4.30 4.68 5.05 5.43 5.80 6.18 6.55 6.93 7.30 7.68 8.05 8.43 8.80 9.18 9.55 9.93 10.30 10.68 11.05 11.43 11.80 12.18 12.55 12.93 13.30 13.68 A 1.01 1.44 1.88 2.32 2.76 3.19 3.63 4.07 4.50 4.94 5.38 5.81 6.25 6.69 7.13 7.56 8.00 8.44 8.87 9.31 9.75 10.18 10.62 11.06 11.50 11.93 12.37 12.81 13.24 13.68 ------B 0.65 1.08 1.52 1.96 2.40 2.83 3.27 3.71 4.14 4.58 5.02 5.45 5.89 6.33 6.77 7.20 7.64 8.08 8.51 8.95 9.39 9.82 10.26 10.70 11.14 11.57 12.01 12.45 12.88 13.32 ------A 1.16 1.73 2.29 2.85 3.42 3.98 4.54 5.10 5.67 6.23 6.79 7.36 7.92 8.48 9.05 9.61 10.17 10.73 11.30 11.86 12.42 12.99 13.55 14.11 ------------B 0.80 1.37 1.93 2.49 3.06 3.62 4.18 4.74 5.31 5.87 6.43 7.00 7.56 8.12 8.69 9.25 9.81 10.37 10.94 11.50 12.06 12.63 13.19 13.75 -------------

.12 (3.0) .18 (4.6) B A

Terminal Block Accessories

MARKING STRIP
.49 (12.4) .12 (3.0) .18 (4.6) B A

.14 (3.6)

Print Styles
01A 01B 1234567 7654321 7654321 01C 01D 1 2 3 4 5 6 7 7 6 5 4 3 2 1
PRINT STYLE

07B

7654321

07D

Ordering Codes
COVER SERIES NO. OF TERMINALS

CW
CB (Black) CW (White) MARKING STRIP

05*

SERIES

NO. OF TERMINALS

SW
NYLON SPRING CLIP SW (White)

05*

110

Datasheets available at marathonsp.com

7 6 5 4 3 2 1

1 2 3 4 5 6 7

07A

1234567

07C

1 2 3 4 5 6 7

7 6 5 4 3 2 1

1234567

01A

PRINT STYLE

01A

Terminal Block Accessories


Double Row - Sub Mounted Marking Strips
Specifications:
Black XP Phenolic Material, 0.03 thick Printed on Top or Bottom Position with Letters or Numbers for Circuit Identification
Printing Character Size is 1/8 Inch

Series 1 # of

Series 2

Series 3
C E

A E F

100/670A GP, 200/671 GP, 300/672 GP 601 GP, 600 GP, 600A Terminals GP, 670A RZ 621 RZ, 671 RZ 602 GP, 672 RZ

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

1.031 1.406 1.781 2.156 2.531 2.906 3.281 3.656 4.031 4.406 4.781 5.156 5.531 5.906 6.281 6.656 7.031 7.406 7.781 8.156 8.531 8.906 9.281 9.656 10.031 10.406 10.781 11.156 11.531 11.906 12.281 12.656 13.031 13.406 13.781 14.156

1.188 1.625 2.063 2.500 2.938 3.375 3.813 4.250 4.688 5.125 5.563 6.000 6.438 6.875 7.313 7.750 8.188 8.625 9.063 9.500 9.938 10.375 10.813 11.250 11.688 12.125 12.563 13.000 13.438 13.875 -------

1.531 2.094 2.656 3.219 3.781 4.344 4.906 5.469 6.031 6.594 7.156 7.719 8.281 8.844 9.406 9.969 10.531 11.094 11.656 12.219 12.781 13.344 13.906 14.469 -------------

B D .06 (1.5)

.12 (3.0)

Terminal Block Accessories

SERIES

100 200 300

1.12 1.37 1.56

.28 .34 .40

.31 .42 .50

.14 .16 .20

.16 .18 .20

Print Styles
1 2 3 4 5 6 7 01A 01B 1234567 01C 01D 7 6 5 4 3 2 1 04C 04D
NO. OF TERMINALS

7654321

04A

1234567

04B

7654321

Ordering Code
SUB MOUNTED (BLACK) SERIES PRINT STYLE

FB

12

Datasheets available at marathonsp.com

111

7 6 5 4 3 2 1

1 2 3 4 5 6 7

01A

Terminal Block Accessories


Marking and Insulator Strips
Kulka marking strips serve as insulation between terminal blocks and chassis, as well as providing a marking surface for terminal identification. When specified, they can be printed to show terminal designations by numbers, letters, symbols or any combination thereof. Insulator strips offer the same properties, but do not provide space for terminal identification. Both marking and insulator strips can be supplied pre-mounted on the back of each block thereby simplifying assembly and inventory control.
DOUBLE ROW MARKING STRIP EXAMPLE SINGLE ROW MARKING STRIP EXAMPLE

DOUBLE ROW MARKING STRIP EXAMPLE

SINGLE ROW MARKING STRIP EXAMPLE

Terminal Block Accessories

Drawing and Dimensions:


Marking and insulator strips are available for Kulka Terminal Blocks. These include double and single row/single row insulated turret. Dimensions for insulator strips do not allow a marking surface.

Order Information:

FEED-THRU STYLE: For feed-thru terminal blocks, see styles 2, 3, 5, 6, 8, & 9 on page 114. Insert applicable feed-thru style designation in ordering code, i.e. Y, YSY, XY, 1904, 1921, 2000, 2004, 2020, 2021, 2104, 2120, 3000. AVAILABILITY: Marking and insulator strips are available to fit most Kulka Terminal Blocks. See SERIES reference numbers on pages 113 and 114 for a complete listing. If not listed, consult Customer Service for availability. Designate appropriate prefix (MS for marking strips or IS for insulator strip) in front of the SERIES number when ordering. Available materials: XP (general purpose laminate), XXXPFR (flame retardant), GME (glass cloth melamine), GEE (glass cloth epoxy).

Printing:
a. b. c. d. e. Marking strips are available in many printing styles. The maximum number of characters per station is two (2). Please specify printing style. If unprinted marking strips are desired, insert the letter X in the printing style space of the ordering code. Printing is the standard method of marking. Printing color is silver (white) on dark surfaces and black on light surfaces. PROTECTIVE COATING: Marking and insulator strips can be supplied with a fungus proof varnish (MIL-V-173A) cover coating. State on order: coat after printing with MIL-V-173A varnish.

*See block dimension for overall length and mounting

Ordering Code:
MS/IS SERIES MAT. CODE

Contact Customer Service for Availability of Materials FEED THRU (IF APPLICABLE) NO. OF TERM PRINT STYLE

MS

601

XP

16

06A

112

Datasheets available at marathonsp.com

Terminal Block Accessories


Marking Strip Dimensions - Single Row
Dimensions K W 0.13 0.14 0.16 0.20 0.06 0.13 0.13 0.06 0.13

Series 411 599 (799) 699 (899) 812 (912)

Style 1, 5, 1, 5, 1, 5, 1, 5, 2, 7, 2, 7, 2, 7, 2, 7, 4 8 4 8 4 8 4 8

D 0.56 0.88 0.81 1.13 0.88 1.13 0.94 1.31

F 0.19 0.44 0.28 0.56 0.34 0.56 0.38 0.66

G 0.37 -0.53 -0.54 -0.56 --

X 0.13 0.16 0.18 0.21

N* 0.41 0.56 0.50 0.75

*N dimension to replace D dimension for insulator strips **Consult Customer Service on marking strips that are for terminal blocks with Z lugs. For overall lengths, reference appropriate terminal block series A & B dimensions

mm = dim X 25.4

Terminal Block Accessories

STYLES 1 & 2
A REF. K TYP B STYLE 1 1 2 3 3 2 1 1 2 3 3 2 1 W STYLE 2 1 2 3 W A 3 2 1 B 1 2 3 3 2 1 D D 3 2 1 3 2 1 3 2 1 3 2 1 D 3 2 1 3 2 1 D D A B C D

F D G REF.

.031 X TYP.

STYLES 4 & 5
A 1 2 3 D G REF. F 1 2 3 STYLE 5 .031 A B C 3 2 1 1 2 3 C 1 2 3 1 2 3 1 2 3 1 2 3 C STYLE 4 B 3 2 1 C 1 2 3

1 2 3 STYLE 7 1 2 3

3 2 1 3 2 1

F D F REF.

1 2 3 E

3 2 1 F

A 3 3 2 1 .031

B 1 2

STYLE 8

1 2 3 1 2 3

3 2 1 3 2 1

1 2 3 E

3 2 1 F

Datasheets available at marathonsp.com

113

1 2

3 2 1

STYLES 7 & 8

Terminal Block Accessories


Marking Strip Dimensions - Double Row
Series 410 600 (800) 601 (801) 602 (802) 603 604 605 Style 1-6 7, 8, 9 1-6 7, 8, 9 1-6 7, 8, 9 1-6 7, 8, 9 1-6 7, 8, 9 1, 4 7 1, 4 7 1-6 7, 8, 9 1-6 7, 8, 9 1-6 7, 8, 9 C 0.25 0.31 0.42 0.50 0.63 0.75 0.88 0.31 0.42 0.50 D 0.75 1.13 1.13 1.38 1.31 1.50 1.50 1.75 1.88 2.13 2.13 2.50 2.69 2.81 1.19 1.50 1.50 1.75 1.63 1.94 F 0.19 0.44 0.28 0.53 0.34 0.55 0.41 0.63 0.59 0.75 0.63 0.88 0.81 0.97 0.28 0.59 0.34 0.67 0.41 0.72 Dimensions G 0.31 -0.53 -0.55 -0.59 -0.66 -0.75 -1.00 -0.60 -0.73 -0.72 -K 0.12 0.14 0.16 0.20 0.22 0.27 0.31 0.14 0.16 0.20 W 0.06 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13
A

X 0.13 0.16 1.75 0.21 0.23 0.23 0.27 0.16 0.18 0.21
B

N* 0.41 0.69 0.88 1.06 1.31 1.50 1.81 0.88 1.13 1.31
C

*N dimension to replace D dimension for insulator strips **Consult Customer Service on marking strips that are for terminal blocks with Z lugs. For overall lengths, reference appropriate terminal block series A & B dimensions

Terminal Block Accessories

670 671 672

mm = dim X 25.4
D

1 2 3

A REF. K TYP F B

3 2 1 W 3 2 1 3 2 1 3 2 1 D 3 2 1 3 2 1 D 3 2 1 3 2 1 D D 3 2 1 3 2 1 3 2 1 D D 3 2 1

STYLES 1, 2 AND 3

STYLE 1

1 2 3

3 2 1

STYLE 2 1 2 3 .031 W 3 2 1 1 2 3 1 2 3 1 2 3 1 2 3 C 1 2 3 1 2 3 C 1 2 3 1 2 3 C C 1 2 3 1 2 3 1 2 3 C C

C G REF.

X TYP.

STYLE 3

1 2 3 A

3 2 1 B

STYLES 4, 5 AND 6
G REF. STYLE 4

A 1 2 3

B 3 2 1

D F

C STYLE 5 .031

1 2 3

3 2 1

1 2 3 STYLE 6

3 2 1

STYLE 7
F D F REF. .031 C STYLE 7

A A 3 2 1

B B 1 2 3 3 2 1 3 2 1 3 2 1 F B 12 3 3 2 1 3 2 1 3 2 1 F B 1 2 3 3 2 1 3 2 1 3 2 1 F

1 2 3 1 2 3 1 2 3 E A

STYLE 8

C D F REF.

.031

STYLE 9

114

3 2 1

3 2 1 1 2 3 1 2 3 1 2 3 E A 1 2 3 1 2 3 1 2 3 E

STYLES 8 AND 9

Datasheets available at marathonsp.com

Terminal Block Accessories


Terminal Block Printing
Numeric Print Styles
STYLE 10A STYLE 10B STYLE 10C STYLE 10D

STYLE 11A

STYLE 11B

STYLE 12A

STYLE 12B

STYLE 12C

STYLE 13A

STYLE 13B

STYLE 13C

STYLE 13D

Alpha Print Styles


STYLE 50A STYLE 50B STYLE 50C STYLE 50D

STYLE 51A

STYLE 51B

STYLE 52A

STYLE 52B

STYLE 52C

STYLE 53A

STYLE 53B

STYLE 53C

STYLE 53D

Datasheets available at marathonsp.com

115

C A

B B

A C

STYLE 51C

STYLE 51D

STYLE 52D

3 1

2 2

1 3

3 3

STYLE 11C

STYLE 11D

3 3

STYLE 12D

2 2

Terminal Block Accessories

3 3 C C

2 2 B B

1 1 A A

1 1 A C A A

2 2 B B B B

3 3 C A A C C

Sectional Terminal Blocks


General Information:
Sectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the block producing the required number of circuits. Marathons DIN Sectional Blocks will fit on a standard 35mm DIN rail. Marathon offers three sizes of sectional terminal blocks: 3/8 centers, 7/16 centers, 1/2 centers and 11/16 sectional fuse holders. All blocks can be ordered with a channel mount base, or a flat mount base for direct mounting to the panel. The 3/8 is also available with a DIN foot; alternatively, the 7/16 is only available with a DIN foot.

Ratings and Standards:


The voltage ratings of terminal blocks are based upon the minimum spacing between electrically conductive parts line to line through air and over surface and line to ground through air and over surface. Class A Service equipment including deadfront switchboards, panel boards, service entrance devices. Class B

Sectional Terminal Blocks

Commercial appliances including business equipment, electronic data processing equipment and the like. Class C General industrial and machine tool controls which can be further defined as equipment falling under UL 508.

Spacing Requirements (in inches):


Voltage Thru Air Over Surface

Class A Class B Class C

51-150 151-300 301-600 51-150 151-300 301-600 51-150 151-300 301-600

.500 .750 1.000 .063 .094 .375 .125 .250 .375

.750 1.250 2.000 .063 .094 .500 .250 .375 .500

Applications:
Designed for electrical termination of wire where flexibility of circuit design is necessary. Accepts single or multiple wire sizes for tubular screw and tubular clamp styles.

116

Datasheets available at marathonsp.com

Sectional Terminal Blocks


3/8 Sectional Channel (C), Flat (F), & DIN Mount 600 Volts AC/DC 32 Circuits per Foot
Specifications:
Meets IP20 Touchproof Requirement UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant
6G38 TS F

Tubular Screw Connector (6G38 TS)


Sectional Terminal Blocks

Materials:
Base - Gray Thermoplastic, 125C (UL RTI) Tubular Screw Connector- Copper, Tin Plated Screw - #10-32 Steel, Nickel Plated Wire Termination Torque 16 in-lb

Wire Ranges:
50 Amps (40 Amps CSA) Single and Multiple Stranded CU (1) #8 - #18 AWG (1-3) #12 AWG (1-4) #14 AWG Wire Combinations: Solid CU (1) #10 - #16 AWG (1-3) #12 AWG (1-4) #14 or #16 AWG

Ordering Code:
6G38 TS F 6G38 TS C 6G38 TS DIN Flat mount block Channel mount block DIN mount block Std pk 100 Std pk 100 Std pk 25 See Figure 2 On Page 118 See Figure 1 On Page 118 See Figure 3 On Page 118

Kant Kut Connector (6G38 TSKK)


Materials:
Base - Gray Thermoplastic, 125C (UL RTI) Kant Kut Connector- Copper, Tin Plated Screw - #10-32, Nickel Plated, Pad - Steel Wire Termination Torque 16 in-lb

Wire Ranges:
40 Amps Single and Multiple Wire Combinations: Stranded CU Solid CU (1) #10-#22 AWG (1) #10 - #14 AWG (1-2) #12 AWG (1-2) #12 or #14 AWG (1-3) #14 AWG (1-4) #16 AWG (1-5) #18 or #22 AWG
WIRE PROTECTOR

Ordering Code:
6G38 TSKK F 6G38 TSKK C 6G38 TSKK DIN Flat mount block Channel mount block DIN mount block

Std pk 100 Std pk 100 Std pk 25

See Figure 2 On Page 118 See Figure 1 On Page 118 See Figure 3 On Page 118

Datasheets available at marathonsp.com

117

Sectional Terminal Blocks


Sectional Terminal Block Accessories
Catalog # Description
Jumper for TS and TSKK Mounting Clamp (For channel style only) Vinyl Marking Strip (1/2 x 2 white) DIN Rail, 35 x 7.5 mm 2 m long, slotted

Std Pk

Catalog #

Description
End bracket for DIN mount base

Std Pk

J 38

50

MSK35

25

MC

25

6G38 E C 6G38 E F 6G38 E DIN MPC-3 (3 ft channel) MPC-6 (6 ft channel)

End bracket for 6G38 versions

SPECIAL PRODUCTS CAT#

25

MS 2

25

Channel

MN35-2

25

Sectional Terminal Block Dimensions - 6G38 TS & TSKK

Sectional Terminal Blocks

FIGURE 1: Channel Mount

A = .78 + (.375 X No. of Lines) [19.8] + [9.5 X No. of Lines) .19 4.8

1.25 31.7 B = .36 + (.375 x No. of Lines) [9.1] + [9.5 X No. of Lines) 1.50 38.1 .22 5.6 .37 9.5 TYP. 1.54 39.2

FIGURE 2: Flat Mount

A = .78 + (.375 X No. of Lines) [19.8] + [9.5 X No. of Lines)

.19 4.8 B = .36 + (.375 x No. of Lines) [9.1] + [9.5 X No. of Lines)

1.25 31.7

.18 4.6

1.26 31.9

.375 9.5 TYP.

FIGURE 3: DIN Mount

B = .22 + (.375 X No. of Lines) [5.6] + [9.5 X No. of Lines)

1.25 31.7

.375 9.5 TYP.

1.54 39.1

1.26 31.9

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

A = .62 [15.7] + B

1.78 45.1

118

Datasheets available at marathonsp.com

Sectional Terminal Blocks


7/16 Sectional Terminal Block 600 Volts AC/DC, 40 Amp 27 Circuits per Foot
Specifications:
UL Recognized File No. XCFR2.E62806, XCFR8.E62806 CSA Certified File No. LR19766 RoHS Compliant

6G44 SP DIN

6G44 SP DIN - Sems Pressure Connector, DIN Mounted


Materials:
Base - Gray Thermoplastic, 125C (UL RTI) Connector - Brass, Tin Plated Screw - #6 with pad, Steel, Nickel Plated

Wire Ranges:
CU Only, Str/Sol Base Wire: Prepared Wire (Lug or Spade): (1) #12-#22 AWG (1) #10-#16 AWG (1-2) #22-12 AWG (1-2) #10-16 AWG Classes B, C, G, H, I, K Wire Termination Torque 10 lb-in

Sectional Terminal Blocks

Sectional Terminal Block Accessories


Catalog #
6G44 E DIN

Description
End Sections

Std Pk
25

LENGTH .10 + (.44 X # of Lines) [2.5 + (11.2 X # of Lines)

MS 44

7/16 marker strip (4 long, white) Jumper (various lengths) End Bracket for DIN Rail DIN Rail 35 x 7.5 mm 2m long, slotted

#6 SCREW W/SADDLE PLATE

601 RJS XX

N/A

END PIECE

MSK35

25
1.31 33.2 1.16 29.5

MN35-2

N/A

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.10 2.5

.44 11.1 TYP.

1.78 45.3

Datasheets available at marathonsp.com

119

Sectional Terminal Blocks


1/2 Sectional 600 Volts AC/DC 24 Circuits per Foot
Specifications:
Base, White Nylon - Type 6/6 105oC Tubular Screw (TSCU) Copper, Tin Plated; Screw #1/4-28 Steel, Nickel Plated Wire Range #4-#16 AWG Copper, 70 Amps Torque 20 lb-in UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR19766 RoHS Compliant Catalog # Description
Tubular Screw

6H12 TSCU C

Std Pk

Catalog #

Description

Std Pk

Sectional Terminal Blocks

For flat mount block

6H12 TSCU F

50

J 12

Jumper

50

For channel mount block

6H12 TSCU C

Tubular Screw

50

MC MPC-3 (3 ft channel) MPC-6 (6 ft channel)

Mounting Clamp

25

For flat mount block

6H12 E F

End Section

SPECIAL PRODUCTS

25

Channel

--

For channel mount block

6H12 E C

SPECIAL PRODUCTS

End Section

25

MS 2

Vinyl Marking Strip - 1/2 x 2

25

Flat Mount:
A B

Channel Mount:
A B

.18 [4.6] .50 [12.7] A = .91 + (.500 x E) B = .37 + (.500 x E) E = No. of Poles .21 X .34 (5.3 X 8.6) .50 [12.7]

SPECIAL PRODUCTS

1.25 [31.8]

1.50 [38.1]

A = .91 + (.500 x E) B = .37 + (.500 x E) E = No. of Poles

1.50 [38.1]

.50 [12.7]

.91 [23.1]

SPECIAL PRODUCTS

1.56 [39.7]

1.50 [38.1]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

1.21 [30.7]

.50 [12.7]

120

Datasheets available at marathonsp.com

Sectional Terminal Blocks


11/16 Sectional Fuse Holder 600 Volt, 30 Amp
(Midget Fuse Holder) Specifications:
Tested and Approved for 10,000 Amp Withstand Rating Base, White Nylon - Type 6/6 105oC Connector Box Type Accepts up to #10 AWG Wire, either Terminated or Non-Terminated Clip, Copper Alloy, Tin Plated UL Recognized File No. IZLT2.E35113 CSA Certified File No. LR21455 RoHS Compliant

6W30A1F with end piece (fuse not included)

Standard 6W30A1F 6W30A1C 6WEF 6WEC MC MPC-6 MPC-3 GR-2

Description Flat Mount Channel Mount End Piece (flat) End Piece (channel) Mounting Clamp 6 Foot Channel 3 Foot Channel 1/8 Diameter X 2 Long Nylon Rod

Std Pack

Wire Range

Fuse Size

Fuses

Sectional Terminal Blocks

A13X-2, A25Z-2, 10 #10-#14 AWG CU 25 STRANDED 13/32 DIA BY 1 1/2 LONG A60Q-2, A6Y-2B, AGU, ATM, ATQ, BAF, BAN, BLF, BLN, BLS, FLA, FLM, FLQ, FNM, FNQ, GFN, GGO, KLK, KLKD, KLQ, KTK, OTM, TRM

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com


"L"
.34 [8.6]

"C"

Flat Mount: L = 0.88 + (0.68 X N) C = 0.48 + (0.68 X N)


1.00 [25.4] 2.00 [50.8]

N = No. of Poles Channel Dimensions: LCH = L + 2.25

.21 [5.3]

.68 [17.4]

.17 [4.3]

2.80 [71.1]

1.95 [49.5]

SPECIAL PRODUCTS

1.70 [43.2]

2.03 [51.6]

.40 [10.2]

.08 [2.0]

.88 [22.4]

Datasheets available at marathonsp.com

121

97949

2.00 [50.8]

13/32 x 1-1/2 FUSE

DIN Rail Terminal Blocks


General Information:
Marathon DIN Rail Terminal Blocks are ideal for various applications such as machine tool controls, distribution and instrumentation installations, switchgear, elevator and panelboard construction.

Insulating Materials:
The moldings are made of Nylon 6/6, Gray. This material has high creepage resistance and high impact strength. It also has a UL 94V-2 flammability rating and is resistant to gasoline, oil, alcohol and many other chemicals.

Temperature Rating:

100C / 212F Continuous 170C / 338F Intermittent & Short Exposure

Connector System:
The connectors are made of copper alloy and are nickel-plated for corrosion resistance. The screws are rolled steel, zinc plated. The total connector system provides the following benefits: 1. The system ensures that no matter how small the cross section of the wire it can only be inserted into the connection hole. 2. A serrated pressure plate eliminates any wire damage from the torquing of the screw. 3. The upward pressure on the screw from the pressure plate reduces the risk of a screw loosening due to vibration. 4. The pressure plate also compensates for some reduction in contact pressure caused by cold flow in the wire. 5. The design of the pressure plate and its heavy construction eliminates tilting, even with solid wires. 6. The use of rolled rather than turned screw threads provide for the application of higher torque without thread damage.

DIN Rail Terminal Blocks

Reference Chart:
Catalog Number MIK3 MIK5 MIK10 MIK16 MIK25 MIKTS4 MIKSI5 MIKE4 MIKE10 MIKE16 Page 123 124 125 126 127 128 129 129 129 129 Amps 20 30 50 65 85 20 10 Volts 600 600 600 600 600 300 300 Wire Range #12-#22 AWG #10-#22 AWG #8-#22 AWG #6-#22 AWG #4-#8 AWG #12-#22 AWG #10-#20 AWG #10-#22 AWG #8 AWG #6 AWG Thickness 5 mm 6 mm 8 mm 10 mm 12 mm 6 mm 8 mm 7 mm 8 mm 10 mm Terminals per Foot 60 50 38 30 25 Wire Termination Torque 5 13.3 13.3 18 53 8.0 13.3 18

See Page 130 for Identification Labels MSK35 - End Bracket Securing Torque 7-9 lb-in (.8-1 N-m)

122

Datasheets available at marathonsp.com

DIN Rail Terminal Blocks


MIK3 5 mm - 600 Volts AC/DC
Specifications:
Insulating Material, Nylon- 6/6, Gray Wire Range #12-#22 AWG 20 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 - 25 Amps VDE 26 Amps RoHS Compliant

MIK3

Catalog #
MIK3 MN35-2 MVB2-2 MVB2-12 MVL2-2 MIW2 MIW4 MKAW2 MSK35

Description
Center Section DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long, steel zinc-plated Jumper 2-position Jumper 12-position Connecting straps for linking together two adjacent 12-pole jumpers Insulating end sections for covering and insulating the last terminal in an assembly Insulating partition walls for visual/electrical separation of terminal groups Safety cover with warning label for line terminals which cannot be disconnected End bracket used on both ends of the assembly to hold blocks in place

DIN Rail Terminal Blocks

Wire strip length 1/4

Dimensions: H = 36 mm (1.417) W = 42 mm (1.653) T = 5 mm (.197)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

123

DIN Rail Terminal Blocks


MIK5 6 mm - 600 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #10-#22 AWG 30 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 - 25 Amps VDE 24 Amps RoHS Compliant

MIK5

Catalog #
MIK5 MN35-2 MVB4-2 MVB4-12 MVL4-2 MSTB2

Description
Center Section DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long, steel zinc-plated Jumper 2-position Jumper 12-position Connecting straps for linking together two adjacent 12-pole jumpers Plug Sockets - test plugs of 2.3 mm Test Plugs - 2.3 mm Insulating end sections for covering and insulating the last terminal Insulating partition walls for visual/electrical separation of terminal groups Safety cover with warning label for line terminals which cannot be disconnected End bracket used on both ends of the assembly to hold blocks in place

DIN Rail Terminal Blocks

MPST2 MIW4 MIW16 MKAW2 MSK35

Wire strip length .30

Dimensions: H = 38 mm (1.496) W = 42 mm (1.653) T = 6 mm (.236)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

124

Datasheets available at marathonsp.com

DIN Rail Terminal Blocks


MIK10 8 mm - 600 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #8-#22 AWG 50 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 - 50 Amps VDE 61 Amps RoHS Compliant

MIK10

Catalog #
MIK10 MN35-2 MVB6-2 MVB6-12 MVL6-2 MSTB2 MPST2 MIW16 MIW50 MKAW10 MSK35 Center Section

Description
DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long / steel zinc-plated Jumper 2-position Jumper 12-position

DIN Rail Terminal Blocks

Connecting straps for linking together two adjacent 12 pole jumpers Plug Sockets- test plugs of 2.3 mm Test Plugs- 2.3 mm Insulating end sections for covering and insulating the last terminal in an assembly Insulating partition walls for visual and electrical separation of terminal groups Safety cover with warning label for line terminals which cannot be disconnected End bracket used on both ends of the assembly to hold blocks in place

Dimensions: H = 44 mm (1.732) W = 42 mm (1.653) T = 8 mm (.315)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

125

DIN Rail Terminal Blocks


MIK16 10 mm - 600 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #6-#22 AWG 65 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 - 68 Amps VDE 82 Amps RoHS Compliant
MIK16

Catalog #
MIK16 MN35-2 MVB16-2 MVB16-12 Center Section

Description
DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long / steel zinc-plated Jumper 2-position Jumper 12-position Removable connecting jumpers for the connection of adjacent lines Connecting straps for linking together two adjacent 12 pole jumpers Insulating end sections for covering and insulating the last terminal in an assembly Insulating partition walls for visual and electrical separation of terminal groups Safety covers with warning label for line terminals which cannot be disconnected End bracket used on both ends of the assembly to hold blocks in place

DIN Rail Terminal Blocks

MVBL16 MVL16-2 MIW16 MIW50 MKAW16 MSK35

Dimensions: H = 44 mm (1.732) W = 42 mm (1.653) T = 10 mm (.394)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

126

Datasheets available at marathonsp.com

DIN Rail Terminal Blocks


MIK25 12 mm - 600 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #4-#8 AWG 85 Amps UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 - 70 Amps VDE 108 Amps RoHS Compliant

MIK25

Catalog #
MIK25 MN35-2 MVB25 MVL25 MVL25-3 MVBU35 MSTB35 MPST4 MIW50 MIW70 MKAW25 MSK35 Center Section

Description
DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long, steel zinc-plated Jumpers 2-position Connecting straps- 2 position

DIN Rail Terminal Blocks

Connecting straps- 3 position Supports for use under the MVL straps using M 6 X 15 screws Plug sockets for test plugs of 4 mm Test plugs- 4 mm Insulating end sections for covering and insulating the last terminal in an assembly Insulating partition walls for visual and electrical separation of terminal groups Safety covers with warning label for supply line terminals which cannot be disconnected End bracket used on both ends of the assembly to hold blocks in place

Dimensions: H = 48 mm (1.89) W = 50 mm (1.97) T = 12 mm (.47)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

127

DIN Rail Terminal Blocks


MIKTS4 (Disconnect) 6 mm - 300 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #12-#22 AWG 20 Amps CSA Certified File No. LR700930 VDE 16 Amps RoHS Compliant
MIKTS4

Catalog #
MIKTS4 MN35-2 MDSBL (Plug only) MDSRT (Plug only) Center Section

Description
DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long / steel zinc-plated Diode plug - blue with diode 400 Volt, 1 Amp cathode on high voltage side Diode plug - red with diode 400 Volt, 1 Amp cathode on low voltage side Test Plug- 2.3 mm Insulating end sections for covering and insulating the last terminal in an assembly End bracket used on both ends of the assembly to hold blocks in place

DIN Rail Terminal Blocks

MPST2 MIW4 MSK35

H1

H2 H3

Dimensions: H1 = 39 mm H2 = 46 mm H3 = 53 mm W = 42 mm T = 6 mm

(1.535) (1.800) (2.100) (1.653) (.236)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

128

Datasheets available at marathonsp.com

DIN Rail Terminal Blocks


MIKSI5 8 mm - 300 Volts AC/DC
Specifications:
Insulating Material, Nylon 6/6, Gray Wire Range #10-#20 AWG 10 Amps VDE - 4 mm2 IEC - 6.3 Amps UL Recognized File No. IZLT2.E35113 10 Amps Fuse Type - 5 x 20 mm, 5 x 25 mm RoHS Compliant Description
Center Section DIN Rail symmetrical 35 X 7.5 mm slotted 2 m long, steel zinc-plated Insulating partition walls for visual and electrical separation of terminal groups End bracket used on both ends of the assembly to hold blocks in place

MIKSI5

Catalog #
MIKSI5 MN35-2 MIW50 MSK35

T
Dimensions: H = 47 mm (1.850) W = 60 mm (2.362) T = 8 mm (.315)

DIN Rail Terminal Blocks

MIKE4, MIKE10, MIKE16 7 mm, 8 mm, 10 mm


Specifications:
Insulating Material, Nylon 6/6, Green/Yellow Wire Range: MIKE4 - #10-#22 AWG MIKE10 - #8 AWG MIKE16 - #6 AWG UL Recognized File No. XCFR2.E62806 CSA Certified File No. LR700930 VDE RoHS Compliant

MIKE10

Dimensions:

H = MIKE4 MIKE10 MIKE16

38 mm (1.496) 44 mm (1.771) 44 mm (1.732)

W = 56 mm (2.204) T = MIKE4 MIKE10 MIKE16 7 mm (.275) 8 mm (.315) 10 mm (.394)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

129

DIN Rail Terminal Blocks


Universal Identification Labels Type MSH
Specifications:
Strips of Ten Large Surface Area Available Plain, with Numbers, Letters or Symbols Can be Labeled Vertically or Horizontally Single Label MSH 5 can be Used for all Sizes RoHS Compliant

Ordering Code:

MSH
LABELS

1-10
SPECIFY PRINTING ORIENTATION H = Horizontal 1 2 V = Vertical

DIN Rail Terminal Blocks

BLOCK SIZE 5 = 5 mm (Fits all sizes) 6 = 6 mm (Fits 6 mm & Larger) 8 = 8 mm (Fits 8-10 mm) 10 = 10 mm PRINTED/UNPRINTED P = Printed U = Unprinted

TYPE OF PRINTING A = Each Strip Printed Identical (Example: All T) B = Each Strip Printed in Sequence (Example: 1-10) C = Custom

130

Datasheets available at marathonsp.com

1 2

Kulka Military Class (A-A-59125) / (MIL-T-55164)


Military Class: Closed Back
Supercedes MIL-T-59125
These military blocks feature molded-in terminals in an improved Kulka design for greater strength and flexibility. The mounting holes are covered with molded-in reinforcement straddle plates.

37TB04B

A-A-59125/ MIL-T-55164 Information Class 37 TB 38 TB 39 TB 40 TB 41 TB 42 TB Spec # /1 /2 /3 /4 /5 /6

Terminal Type Description Double Screw Double Screw Double Screw Single Screw Feed Thru Single Screw Feed Thru Single Screw Feed Thru

Voltage Max Rated 300 V RMS 600 V RMS 600 V RMS 300 V RMS 600 V RMS 600 V RMS Dielectric with Test 3000 V RMS 3400 V RMS 4000 V RMS 3000 V RMS 3400 V RMS 4000 V RMS

Current Max Rated 15 Amp 60 Hz 20 Amp 60 Hz 30 Amp 60 Hz 7.5 Amp 60 Hz 10 Amp 60 Hz 15 Amp 60 Hz Screw Size #6 #6 #8 #6 #6 #8

Wire & Lug Information RECMD Max Wire Size #16 AWG #14 AWG #10 AWG #18 AWG #16 AWG #14 AWG MS17143 Lug # -11 -14 -9 -10 -14 -8 Max Lug Width 0.282 [7.2] 0.31 [7.9] 0.41 [10.4] 0.282 [7.2] 0.31 [7.9] 0.41 [10.4] RECMD Torque Lb-In (N-M) 8-10 [0.9-1.1] 8-10 [0.9-1.1] 10-12 [1.1-1.4] 8-10 [0.9-1.1] 8-10 [0.9-1.1] 10-12 [1.1-1.4]

Military/Navy Terminal Blocks

*Marathon Special Products manufactures terminal blocks that are constructed to meet MIL-T-55164C and A-A-59125. Mil standard A-A-59125, dated September 16, 1997, superceeds MIL-T-55164C. We will continue to supply the same parts for this spec. The CID identifier will be the same class number as for MIL-T-55164C. The old MIL-T-55164C standard required Group A and Group B testing. The Group B testing was required every three years. Since the new A-A-59125 standard does not require Group B testing, we have elected to discontinue this test. We will continue to do Group A testing. The following blocks are effected by this change: Class/Spec # 37TB / 1 38TB / 2 39TB / 3 40TB / 4 41TB / 5 42TB / 6

Datasheets available at marathonsp.com

131

Kulka Military Class (A-A-59125) / (MIL-T-55164)


37TB-B/40TB-B Series

300 Volts AC/DC


Specifications:
Base, Valox 420-SEO, Grey Color, 130C Closed Back Design Screws, Brass Nickel Plate, 6-32 Binder Head, Slotted Terminals, Brass Nickel Plate, Ultrasonically Inserted 2-20 Poles, Consult Customer Service for Longer Lengths 3/8 Centers Flammability Rating 94 V-O Wire Size #16 15 Amps Parts are supplied with end plates RoHS Compliant
Catalog Number 37TB02B 37TB03B 37TB04B 37TB05B 37TB06B 37TB07B 37TB08B 37TB09B 37TB10B 37TB11B 37TB12B 37TB13B 37TB14B 37TB15B 37TB16B 37TB17B 37TB18B 37TB19B 37TB20B Number of Poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Dimensions A B 1.41 1.12 1.78 1.50 2.16 1.88 2.53 2.25 2.91 2.62 3.28 3.00 3.66 3.38 4.03 3.75 4.41 4.12 4.78 4.50 5.16 4.88 5.53 5.25 5.91 5.62 6.28 6.00 6.66 6.38 7.03 6.75 7.41 7.12 7.78 7.50 8.16 7.88
37TB04B

40TB04B

Hardware Options:
Lug Types (Commercial): 3/4 ST 600 = Half Solder ST600 = Full Solder See Page 106 See Page 106

Feed-Thru Hardware Options:


Long Feed-Thru Solder 40TB B Only

Military/Navy Terminal Blocks

Accessories: (Jumper Commercial Grade)


Marking Strips = MSA, MSB, MSC Jumper = J600, 600RJ, 600RJ(S) See Page 137 See Page 107

Service Options:
Consult Customer Service
.48 .17 [4.3] [12.1] .33 [8.3]

A .14 [3.6] .38 [9.5] .63 [15.9] .31 .31 [7.9] #6-32 X .23[5.7] BD HD SCREW [7.9] B

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

.87 [22.1]

132

Datasheets available at marathonsp.com

Kulka Military Class (A-A-59125) / (MIL-T-55164)


37TB-Military Class (A-A-59125/1)/(MIL-T-55164/1)
Molded Material:
Plastic: Grade F temperature rating 155C per MIL-M-14 Screws: Brass per QQ-W-321, nickel plated per QQ-N-290 Terminal Plates: Brass per QQ-B-613, nickel plated per QQ-N-290
Military Type Designation 37TB 02 F 37TB 03 F 37TB 04 F 37TB 05 F 37TB 06 F 37TB 07 F 37TB 08 F 37TB 09 F 37TB 10 F 37TB 11 F 37TB 12 F 37TB 13 F 37TB 14 F 37TB 15 F 37TB 16 F 37TB 17 F 37TB 18 F 37TB 19 F 37TB 20 F 37TB 21 F 37TB 22 F 37TB 23 F 37TB 24 F 37TB 25 F 37TB 26 F 37TB 27 F 37TB 28 F 37TB 29 F 37TB 30 F 37TB 31 F mm=dim X 25.4 Number of poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Dimensions A B 1.360-1.453 1.109-1.156 1.735-1.828 1.484-1.531 2.110-2.203 1.859-1.906 2.500-2.593 2.234-2.281 2.876-2.969 2.609-2.656 3.250-3.343 2.984-3.031 3.626-3.719 3.359-3.406 4.000-4.093 3.734-3.781 4.376-4.469 4.109-4.156 4.750-4.843 4.484-4.531 5.126-5.219 4.859-4.906 5.500-5.593 5.234-5.281 5.876-5.969 5.609-5.656 6.250-6.365 5.969-6.047 6.626-6.735 6.344-6.422 7.000-7.109 6.719-6.797 7.376-7.485 7.094-7.172 7.752-7.812 7.469-7.547 8.127-8.187 7.844-7.922 8.502-8.562 8.219-8.297 8.877-8.937 8.594-8.672 9.252-9.312 8.969-9.047 9.627-9.687 9.344-9.422 10.002-10.062 9.719-9.797 10.377-10.437 10.094-10.172 10.752-10.812 10.469-10.547 11.127-11.187 10.844-10.922 11.502-11.562 11.219-11.297 11.877-11.937 11.594-11.672 12.252-12.312 11.969-12.047

Electrical Rating:
Rated voltage (maximum): 300 volts Current rating: 15 Amps D.W.V.: 3000 volts RMS

A .14 [3.6] B .38 [9.5] .16 [4.2]

.46 [11.6] .33 [8.3]

.63 [15.9] .30 [7.6] #6-32 X .23[5.7] BD HD SCREW .31 [7.9]

.88 [22.2]

Military/Navy Terminal Blocks

38TB-Military Class (A-A-59125/2)/(MIL-T-55164/2)


Molded Material:
Plastic: Grade F temperature rating 155C per MIL-M-14 Screws: Brass per QQ-W-321, nickel plated per QQ-N-290 Terminal Plates: Brass per QQ-B-613, nickel plated per QQ-N-290

Electrical Rating:
Rated voltage (maximum): 600 volts Current rating: 20 Amps D.W.V.: 3400 volts RMS
A .16 [4.0] B .44 [11.1] .20 [5.0] .56 [14.2] .39 [9.9] .82 [20.8]

.33 [8.4] #6-32 UNC-2A x .25[6.3] BD HD SCREW

.42 [10.7]

1.13 [28.6]

Military Type Number Designation of poles 38TB 02 F 2 38TB 03 F 3 38TB 04 F 4 38TB 05 F 5 38TB 06 F 6 38TB 07 F 7 38TB 08 F 8 38TB 09 F 9 38TB 10 F 10 38TB 11 F 11 38TB 12 F 12 38TB 13 F 13 38TB 14 F 14 38TB 15 F 15 38TB 16 F 16 38TB 17 F 17 38TB 18 F 18 38TB 19 F 19 38TB 20 F 20 38TB 21 F 21 38TB 22 F 22 38TB 23 F 23 mm=dim X 25.4

Dimensions A B 1.579-1.672 1.296-1.343 2.016-2.109 1.734-1.781 2.454-2.547 2.172-2.219 2.891-2.984 2.609-2.656 3.329-3.422 3.046-3.093 3.766-3.859 3.484-3.531 4.204-4.297 3.937-3.984 4.641-4.734 4.375-4.422 5.079-5.172 4.812-4.859 5.532-5.625 5.250-5.297 5.969-6.078 5.687-5.734 6.407-6.516 6.110-6.188 6.844-6.953 6.547-6.625 7.282-7.391 6.985-7.063 7.719-7.828 7.422-7.500 8.157-8.266 7.860-7.938 8.594-8.703 8.297-8.375 9.079-9.156 8.750-8.828 9.517-9.594 9.188-9.266 9.954-10.031 9.625-9.703 10.392-10.469 10.063-10.141 10.829-10.906 10.500-10.578

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

133

Kulka Military Class (A-A-59125) / (MIL-T-55164)


39TB-Military Class (A-A-59125/3)/(MIL-T-55164/3)
Molded Material:
Plastic: Grade F temperature rating 155C per MIL-M-14 Screws: Brass per QQ-W-321, nickel plated per QQ-N-290 Terminal Plates: Brass per QQ-B-613, nickel plated per QQ-N-290
Military Type Designation 39TB 02 F 39TB 03 F 39TB 04 F 39TB 05 F 39TB 06 F 39TB 07 F 39TB 08 F 39TB 09 F 39TB 10 F 39TB 11 F 39TB 12 F 39TB 13 F 39TB 14 F 39TB 15 F 39TB 16 F 39TB 17 F 39TB 18 F
mm=dim X 25.4

Electrical Rating:
Rated voltage (maximum): 600 volts Current rating: 30 Amps D.W.V.: 4000 volts RMS
A .20 [5.2] .56 [14.3] B .22 [5.7] .69 [17.4] .45 [11.4]

.94 [23.8] .43 [10.8] #8-32 UNC-2A x .281[7.1] BD HD SCREW .50 [12.7]

1.31 [33.3]

Number of poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Dimensions A B 2.047-2.140 1.672-1.719 2.626-2.719 2.234-2.281 3.188-3.281 2.796-2.843 3.750-3.843 3.359-3.406 4.313-4.406 3.922-3.969 4.876-4.969 4.484-4.531 5.438-5.531 5.046-5.093 6.000-6.109 5.625-5.672 6.563-6.672 6.172-6.250 7.126-7.235 6.719-6.797 7.688-7.797 7.297-7.375 8.250-8.359 7.860-7.938 8.813-8.922 8.422-8.500 9.376-9.485 8.985-9.063 9.938-10.047 9.547-9.625 10.500-10.609 10.110-10.188 11.079-11.188 10.672-10.750

Military/Navy Terminal Blocks

40TB-Military Class (A-A-59125/4)/(MIL-T-55164/4)


Molded Material:
Same as 37 TB Class Hardware: Lug, Brass per QQ-B-613, tin plated

Electrical Rating:
Rated voltage (maximum): 300 volts Current rating: 7.5 Amps D.W.V.: 3000 volts RMS

A .14 [3.6] B .38 [9.5] .16 [4.2]

.46 [11.6] .33 [8.3]

.63 [15.9] .30 [7.6] #6-32 UNC-2A x .22[5.6] BD HD SCREW .31 [7.9] FEED THRU SOLDER LUG .44 [11.3]

.88 [22.2]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Military Type Designation 40TB 02 F 40TB 03 F 40TB 04 F 40TB 05 F 40TB 06 F 40TB 07 F 40TB 08 F 40TB 09 F 40TB 10 F 40TB 11 F 40TB 12 F 40TB 13 F 40TB 14 F 40TB 15 F 40TB 16 F 40TB 17 F 40TB 18 F 40TB 19 F 40TB 20 F 40TB 21 F 40TB 22 F 40TB 23 F 40TB 24 F 40TB 25 F 40TB 26 F 40TB 27 F 40TB 28 F 40TB 29 F 40TB 30 F 40TB 31 F
mm=dim X 25.4

Number of poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

Dimensions A B 1.360-1.453 1.109-1.156 1.735-1.828 1.484-1.531 2.110-2.203 1.859-1.906 2.500-2.593 2.234-2.281 2.876-2.969 2.609-2.656 3.250-3.343 2.984-3.031 3.626-3.719 3.359-3.406 4.000-4.093 3.734-3.781 4.376-4.469 4.109-4.156 4.750-4.843 4.484-4.531 5.126-5.219 4.859-4.906 5.500-5.593 5.234-5.281 5.876-5.969 5.609-5.656 6.250-6.365 5.969-6.047 6.626-6.735 6.344-6.422 7.000-7.109 6.719-6.797 7.376-7.485 7.094-7.172 7.752-7.812 7.469-7.547 8.127-8.187 7.844-7.922 8.502-8.562 8.219-8.297 8.877-8.937 8.594-8.672 9.252-9.312 8.969-9.047 9.627-9.687 9.344-9.422 10.002-10.062 9.719-9.797 10.377-10.437 10.094-10.172 10.752-10.812 10.469-10.547 11.127-11.187 10.844-10.922 11.502-11.562 11.219-11.297 11.877-11.937 11.594-11.672 12.252-12.312 11.969-12.047

134

Datasheets available at marathonsp.com

Kulka Military Class (A-A-59125) / (MIL-T-55164)


41TB-Military Class (A-A-59125/5)/(MIL-T-55164/5)
Molded Material:
Same as 38 TB Class Hardware: Lug, Brass per QQ-B-613, tin plated
Military Type Designation 41TB 02 F 41TB 03 F 41TB 04 F 41TB 05 F 41TB 06 F 41TB 07 F 41TB 08 F 41TB 09 F 41TB 10 F 41TB 11 F 41TB 12 F 41TB 13 F 41TB 14 F 41TB 15 F 41TB 16 F 41TB 17 F 41TB 18 F 41TB 19 F 41TB 20 F 41TB 21 F 41TB 22 F 41TB 23 F
mm=dim X 25.4

Electrical Rating:
Rated voltage (maximum): 600 volts Current rating: 10 Amps D.W.V.: 3400 volts RMS
A .16 [4.0] B .44 [11.1] .20 [5.0] .56 [14.2] .39 [9.9] 1.13 [28.6]

.33 [8.4] FEED THRU SOLDER LUG

.42 [10.7]

.82 [20.8]

#6-32 UNC-2A x .25[6.3] BD HD SCREW

.63 [15.9]

Number of poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Dimensions A B 1.579-1.672 1.296-1.343 2.016-2.109 1.734-1.781 2.454-2.547 2.172-2.219 2.891-2.984 2.609-2.656 3.329-3.422 3.046-3.093 3.766-3.859 3.484-3.531 4.204-4.297 3.937-3.984 4.641-4.734 4.375-4.422 5.079-5.172 4.812-4.859 5.532-5.625 5.250-5.297 5.969-6.078 5.687-5.734 6.407-6.516 6.110-6.188 6.844-6.953 6.547-6.625 7.282-7.391 6.985-7.063 7.719-7.828 7.422-7.500 8.157-8.266 7.860-7.938 8.594-8.703 8.297-8.375 9.079-9.156 8.750-8.828 9.517-9.594 9.188-9.266 9.954-10.031 9.625-9.703 10.392-10.469 10.063-10.141 10.829-10.906 10.500-10.578

Military/Navy Terminal Blocks

42TB-Military Class (A-A-59125/6)/(MIL-T-55164/6)


Molded Material:
Same as 39 TB Class Hardware: Lug, Brass per QQ-B-613, tin plated

Electrical Rating:
Rated voltage (maximum): 600 volts Current rating: 15 Amps D.W.V.: 3400 volts RMS

A .20 [5.2] .56 [14.3] B .22 [5.7]

.69 [17.4] .45 [11.4]

Military Type Designation 42TB 02 F 42TB 03 F 42TB 04 F 42TB 05 F 42TB 06 F 42TB 07 F 42TB 08 F 42TB 09 F 42TB 10 F 42TB 11 F 42TB 12 F 42TB 13 F 42TB 14 F 42TB 15 F 42TB 16 F 42TB 17 F 42TB 18 F
mm=dim X 25.4

Number of poles 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Dimensions A B 2.047-2.140 1.672-1.719 2.626-2.719 2.234-2.281 3.188-3.281 2.796-2.843 3.750-3.843 3.359-3.406 4.313-4.406 3.922-3.969 4.876-4.969 4.484-4.531 5.438-5.531 5.046-5.093 6.000-6.109 5.625-5.672 6.563-6.672 6.172-6.250 7.126-7.235 6.719-6.797 7.688-7.797 7.297-7.375 8.250-8.359 7.860-7.938 8.813-8.922 8.422-8.500 9.376-9.485 8.985-9.063 9.938-10.047 9.547-9.625 10.500-10.609 10.110-10.188 10.079-11.188 10.672-10.750

.94 [23.8] .50 [12.7] #8-32 UNC-2A x .281[7.1] BD HD SCREW

1.31 [33.3]

.43 [10.8] FEED THRU SOLDER LUG

.63 [15.9]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

135

*Solder Hardware Dimensions are not to Mil Spec

Kulka Military Class (A-A-59125) / (MIL-T-55164)


37TBLS (Commercial Equivalent)
.45 [11] .23 [5.9] .16 [4.0] .922 [23] .31 [7.9] .03 [0.8]

37TBLD (Commercial Equivalent)


1.22 [31.0] 1.22 [31.0] .75 [19.1] .69 [17.5] .16 [4.0]

.03 [.76]

.28 [7.1]

.16 [4.1]

.06 [1.6] .31 [7.9]

.09 [2.3]

(2 HOLES)

.144 (2 HOLES) [3.6]

.28 [7.1]

.16 [4.1]

.06 [1.6]

.144 2-HOLES [3.6] .09 HOLE [2.3]

This is an assembly of the 37TB Class Terminal Board and a two-sided terminal lug (ST600). Available in lengths from 2 terminals through 31 terminals. Lugs are brass, tin plated.

This is an assembly of the 37TB Class Terminal Board and a one-sided terminal lug (3/4 ST600). Available in lengths from 2 terminals through 31 terminals. Lugs are brass, tin plated.

38TBLD (Commercial Equivalent)


1.58 [40.1] 1.58 [40.1] .94 [23.8] .84 [21.4] .036 [.91] .22 [5.6]

38TBLS (Commercial Equivalent)


.58 [15] .32 [8.1] .22 [5.6] 1.17 [29.7] .42 [11]

.036 [.91]

Military/Navy Terminal Blocks

.31 [7.9]

.22 [5.6]

.06 [1.6]

.13 2-HOLES .42 [11] [3.3] .15 2-HOLES [3.8]

.31 [7.9]

.22 [5.6]

.06 [1.6]

.15 2-HOLES [3.8] .13 2-HOLES [3.3]

This is an assembly of the 38TB Class Terminal Board and a two-sided terminal lug (ST601). Available in lengths from 2 terminals through 23 terminals. Lugs are brass, tin plated.

This is an assembly of the 38TB Class Terminal Board and a one-sided terminal lug (3/4 ST601). Available in lengths from 2 terminals through 23 terminals. Lugs are brass, tin plated.

39TBLD (Commercial Equivalent)


1.85 [47.0] 1.85 [47.0] 1.06 [26.9] .94 [23.9] .037 [0.9] .28 [7.1]

39TBLS (Commercial Equivalent)


.69 [18] .39 [9.9] .28 [7.1] 1.37 [34.8] .50 [13] .037 [0.9]

.41 [10]

.28 [7.1]

.09 [2.4]

.50 [13]

.13 2-HOLES [3.3] .177 2-HOLES [4.5]

.41 [10]

.28 [7.1]

.09 [2.4]

.177 2-HOLES [4.5] .13 HOLE [3.3]

This is an assembly of the 39TB Class Terminal Board and a two-sided terminal lug (ST602). Available in lengths from 2 terminals through 18 terminals. Lugs are brass, tin plated.

This is an assembly of the 39TB Class Terminal Board and a one-sided terminal lug (3/4 ST602). Available in lengths from 2 terminals through 18 terminals. Lugs are brass, tin plated.

To ensure solderability, use within six (6) months. For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

136

Datasheets available at marathonsp.com

Kulka Military Class Marking Strips


Marking Styles MSA, MSB, MSC
MSA MSB MSC (blank)

2
MSA

MSB (blank)

Bottom Surface of Marking Strip


Requirements:
Type Mount: Dimensions: Material: Marking:

Bottom Only See Below Type GME Marking Strips shall be Marked in Accordance with CID A-A-59125 (can be provided to MIL T55164)

A single letter shall be inserted in the above type designation to specify the marking style (A, B or C).
STYLE 1 REF. Both the front and the back of the marking strips shall be marked as indicated. The numbersA shall be K B marked at a 45 2 angle with reference to the side of the marking strip, as indicated. TYP

Type MSC37TB (blank single sided marking strip) shall have the same dimensions as type MSA. C D
G REF. X TYP. .031

Series 37TB 38TB 39TB

Style MSA, MSC MSB MSA, MSC MSB MSA, MSC MSB

C 0.31 0.42 0.50

D 1.19 1.50 1.50 1.75 1.63 2.00

F 0.28 0.59 0.34 0.67 0.41 0.69

Dimensions G 0.60 -0.69 -0.75 --

K 0.14 0.16 0.20 D


F

W 0.13 0.13 0.13

X 0.16 0.18 0.21

G REF.

Styles MSA & MSC:


A REF. K TYP F B

Style MSB: A
STYLE 1 1 2 3

1 2 3

3 2 1

F STYLE 2 F REF. X TYP. .031 W .031 STYLE 3 1 2 3 3 2 1 D C 1 2 3 3 2 1 D C G REF.

1 2 3 A

3 2 1

1 2 3

Datasheets available at marathonsp.com


G REF.

137
C STYLE 4

A F1 2 3

1 2 3

3 2 1

4 4
MSC (blank)
STYLE 2 W

Top Surface of Marking Strip

N* 0.88 1.13 1.31


*N dimension to replace D dimension for insulator strips **Consult Customer Service on marking strips that are for terminal blocks with Z lugs. For overall lengths, reference appropriate terminal block series A & B dimensions
.031

STYLE 3

STYLE 4

STYLE 5

STYLE 6

Military/Navy Terminal Blocks

3 2 1

W STYLE 7

3 2 1

D STYLE 8

B 3 2 1

Kulka Navy Class (A-A-59125) / (MIL-T-55164)


Notes:
Molded material is MAI-60 in accordance with MIL-M-14 (+Molded material is GDI30F). The stud connector for these terminal boards is considered part of the stud and is required, unless otherwise specified. With the stud connector removed, the terminal board will provide twice the number of connection points and allow for an additional wire per terminal.

Nuts and connectors are provided when appropriate. They are unplated brass and shipped unassembled.
A-A-59125/ MIL-T-55164 Information Class Spec # Terminal Type Description Voltage Max Rated Dielectric with Test Current Max Rated Screw Size RECMD Max Wire Size

4TB08F

Wire & Lug Information MS17143 Lug # Max Lug Width RECMD Torque Lb-In (N-M)

3 TB 4 TB 5 TB 6 TB 7 TB 8 TB 8 TBHT+ 9 TB 10 TB 11 TB 15 TB 16 TB 17 TB 18 TB 25 TB 25 TBHT+ 26 TB 26 TBHT+

/9 / 10 / 11 / 12 / 13 / 14 / 15 / 16 / 17 / 19 / 20 / 21 / 22 / 23 / 24

Single Stud Single Row Single Stud Double Row Feed Thru Stud Single Row Single Stud Double Row Feed Thru Stud Single Row Double Stud Double Row Single Stud Single Row Single Stud Double Row Feed Thru Stud Single Row Single Stud Double Row Single Stud Double Row Double Stud Double Row Single Stud Single Row Single Stud Single Row Double Stud Double Row

600 V RMS 600 V RMS 600 V RMS 600 V RMS 600 V RMS 300 V RMS 300 V RMS 600 V RMS 600 V RMS 600 V RMS 1000 V RMS 600 V RMS 600 V RMS 300 V RMS 300 V RMS

2000 V RMS 2200 V RMS 2200 V RMS 2200 V RMS 2200 V RMS 1500 V RMS 1500 V RMS 2200 V RMS 2200 V RMS 2200 V RMS 3000 V RMS 2200 V RMS 2200 V RMS 1500 V RMS 1500 V RMS

45 Amp 60 Hz 40 Amp 60 Hz 50 Amp 60 Hz 30 Amp 60 Hz 40 Amp 60 Hz 30 Amp 60 Hz 35 Amp 60 Hz 30 Amp 60 Hz 40 Amp 60 Hz 30 Amp 60 Hz 40 Amp 60 Hz 40 Amp 60 Hz 45 Amp 60 Hz 25 Amp 60 Hz 20 Amp 60 Hz

#8 #8 #8 #6 #6 #5 #6 #6 #6 #8 #8 #6 #8 #4 #4

#10 AWG #12 AWG #10 AWG #14 AWG #12 AWG #14 AWG #12 AWG #14 AWG #12 AWG #14 AWG #12 AWG #12 AWG #10 AWG #14 AWG #16 AWG

-3 -3 -3 -5 -6 -11 -15 -8 -3 -3 -3 -17 -20

0.395 [10.0] 0.395 [10.0] 0.395 [10.0] 0.307 [7.8] 0.307 [7.8] 0.282 [7.2] 0.307 [7.8] 0.242 [6.11] 0.242 [6.1] 0.307 [7.8] 0.395 [10.0] 0.395 [10.0] 0.395 [10.0] 0.242 [6.1] 0.242 [6.1]

16-18 [1.8-2.0] 16-18 [1.8-2.0] 16-18 [1.8-2.0] 10-12 [1.1-1.4] 10-12 [1.1-1.4] 8-10 [0.9-1.1] 10-12 [1.1-1.4] 10-12 [1.1-1.4] 10-12 [1.1-1.4] 16-18 [1.8-2.0] 16-18 [1.8-2.0] 10-12 [1.1-1.4] 16-18 [1.8-2.0] 6-8 [0.7-0.9] 6-8 [0.7-0.9]

Military/Navy Terminal Blocks

*Marathon Special Products manufactures terminal blocks that are constructed to meet MIL-T-55164C and A-A-59125. Mil standard A-A-59125, dated September 16, 1997, superceeds MIL-T-55164C. We will continue to supply the same parts for this spec. The CID identifier will be the same class number as for MIL-T-55164C. The old MIL-T-55164C standard required Group A and Group B testing. The Group B testing was required every three years. Since the new A-A-59125 standard does not require Group B testing, we have elected to discontinue this test. We will continue to do Group A testing. The following blocks are effected by this change: Class/Spec # 3TB / 9 4TB / 10 5TB / 11 6TB / 12 7TB / 13 8TB / 14 9TB / 15 10TB / 16 11TB / 17 15TB / 19 16TB / 20 17TB / 21 18TB / 22 25TB / 23 26TB / 24

138

Datasheets available at marathonsp.com

Kulka Navy Class (A-A-59125) / (MIL-T-55164)


3TB SERIES
7.38 [187.5] .25 [6.4] .59 [15] .11R [2.8]
10 1 2 3 4 5 6 7 8 9

(A-A-59125/9) / MIL-T-55164/9)
Catalog number: 3TB10F

6.88 [174.8] .41 [10] .010 NO. 8-32 NC-2 STUD .44 [11] 1.06 [26.9] .50 [13] .63 [16] .88 [22]

NOTE: 10 TERMINALS 10 NUTS

.28 [7.1]

MOUNT WITH NO. 10 SCREW (2-REQ'D)

4TB SERIES

A .25 [6.4] .41 [10.4] .010 B

(A-A-59125/10) / (MIL-T-55164/10)
Double Row, Front Connection # of Dim. Dim. Type Term A B Nuts 4 TB 08F 4 TB 20F 8 20 3.38 6.50 2.88 6.00 8 20

.53 [13.5] .44 [11.1]

.11R [2.8]

.81 [20.6] MOUNT WITH NO.10 SCREW (2 REQ'D) .28 [7.1] .59 [14.9] REF.

1.81 [46.0]

mm = dim X 25.4

.38 [9.5] NO.8-32 NC-2 STUD .78 [19.8]

5TB SERIES

A .25 [6.4] B .41 [10.4] .59 [15] .11 R [2.79]


10 1 2 3 4 5 6 7 8 9

Military/Navy Terminal Blocks

(A-A-59125/11) / (MIL-T-55164/11)

.010

.31 [7.9] .31 [7.9]

Single Row, Through Connection Type 5 TB 08F 5 TB 10F # of Term 8 10 Dim. A 6.13 7.38 Dim. B 5.63 6.88 Nuts 16 20

1.06 [26.9] NO.8-32 NC-2 STUD

MOUNT WITH NO. 10 SCREW (2-REQ'D) .28 [7.1] .63 [16]

.63 [16] 1.38 [34.9]

.38 [9.5]

mm = dim X 25.4

6TB SERIES

A .25 [6.4] .44 [11.1] B .32 [8.13] .31 [7.9]

(A-A-59125/12) / (MIL-T-55164/12)

Double Row, Front Connection Type 6 TB 06F 6 TB 10F 6 TB 24F # of Term 6 10 24 Dim. A 2.50 3.38 6.50 Dim. B 2.00 2.88 6.00 Nuts 6 10 24
10 2 4 6 8

.11R [2.79]

.69 [17.5]

1.44 [36.5] .38

mm = dim X 25.4

.28 [7.1] MOUNT WITH NO. 10 SCREW (2 REQ'D)

.53 [14]

NO.6-32 NC-2 STUD

[9.5] .63 [19]

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

139

Kulka Navy Class (A-A-59125) / (MIL-T-55164)


6.50

7TB SERIES

[165.1] .25 [6.4] .44 [11] .75 [19.1] .50 [12.7] 1.00 NOTE: 12 TERMINALS 24 NUTS 6-32 UNC-2A STUD [25.4] 6.00 [152.4] .50 [12.7] .31 [7.9]
10 12 11

(A-A-59125/13) / (MIL-T-55164/13)
Catalog number: 7TB12F

.31 [7.9]

R .09 [2.4]
2 1 3

.22 [5.5] MOUNT WITH NO.8 SCREW (2 REQ'D) .32 [8.1] .010

.48 [12]

8TB SERIES

A .19 [4.7] .30 R .09 [2.3] [7.49] B

(A-A-59125/14) / (MIL-T-55164/14)
Double Row, Linked Front Connection # of Term. Type 8 TB 02F 8 TB 06F 8 TB 08F 8 TB 10F
w/stud w/o stud connectors connectors

MOUNT WITH NO. 8 SCREW (2-REQ'D) .50 [12.7] .88 .28 [7.1] [22.2]

2 6 8 10

4 12 16 20

Dim. A 1.63 3.13 3.88 4.63

Dim. B 1.25 2.75 3.50 4.25

Nuts 4 12 16 20

.21 [5.3]

.38 [9.5]

.40 [10.2] NO. 5-40N C -2 STUD

.31 [7.9] .50 [12.7]

8TBHT also available

mm = dim X 25.4

9TB SERIES

.60 .35 [8.9] .32 [8.1] [15.2] .38 [9.5] A 1 .20 [5.0]

(A-A-59125/15) / (MIL-T-55164/15) Military/Navy Terminal Blocks

A .91 [23.0] 2

Single Row, Front Connection Type 9 TB 02F 9 TB 04F # of Term. 2 4 Dim. A 1.48 2.37 Nuts 2 4
.44 [11.1] .31 [7.9] SECTION A-A

A .50 NO. 6-32 NC-2 STUD [12.7] .63 [15.9]

mm = dim X 25.4

10TB SERIES

A .25 [6.4] B .38 [9.7] R .11 [2.8]


10 12 2 4 6 8

(A-A-59125/16) / (MIL-T-55164/16)
Double Row, Front Connection Type 10 TB 18F 10 TB 28F # of Term. 18 28 Dim. A Dim. B 4.63 6.50 4.13 6.00 Dim. C 0.56 0.56 Nuts 18 28

.31 .70 [17.7] [8.0]

1.31 [33.3] .38 [9.5] .69 [17.5]

11

MOUNTS WITH NO. 10 SCREW C (2 REQ'D)

.28 [7.1] .25 [6.4]

mm = dim X 25.4

11TB SERIES

A .25 [6.4] B .38 [9.5] .63 [15.9] .31 [7.9] .31 [7.9]

(A-A-59125/17) / (MIL-T-55164/17)
Single Row, Through Connection Type 11 TB 04F 11 TB 06F 11 TB 14F # of Term. Dim. A 4 6 14 2.50 3.38 6.50 Dim. B Dim. C 2.00 2.88 6.00 0.44 0.44 0.56 Nuts 8 12 28

R .09 [2.4] .25 MOUNTS WITH NO. 8 SCREW .22 [5.5] [6.4]

C .50 [12.7] NO. 6-32 NC-2 STUD

.50 [12.7] 1.00 [25.4]

mm = dim X 25.4 (2 REQ'D)

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

140

Datasheets available at marathonsp.com

Kulka Navy Class (A-A59125) / (MIL-T-55164)


15TB SERIES
A .25 [6.4] B .44 [11.3] .69 [17.5] .44 [11.1]

(A-A-59125/19) / (MIL-T-55164/19)
Double Row, Front Connection Type 15 TB 10F 15 TB 24F Number of Terminals 10 24

10

1.44 [36.5]

Dim. A 3.38 6.50

Dim. B 2.88 6.00

Nuts 10 24

[2.8]

.28 [7.1] MOUNTS WITH NO. 10 SCREW (2-REQ'D) .32 [8.1]


A .25 [6.3] B .53 [13.5] A R.11
6 2

R .11

.53 [13.5]

.38 [9.5] .63 NO. 8-32 NC-2 STUD [15.9]

mm = dim X 25.4

(A-A-59125/20) / (MIL-T-55164/20)
Double Row, Front Connection Type 16 TB 04F 16 TB 10F Number of Terminals 4 10 Dim. A 3.38 6.50 Dim. B 2.88 6.00 Nuts

16TB SERIES

.44 [11.1]

[2.8]

.81 [20.6]
1 3 5 7

1.81 [46.0]

4 10
.28 [7.1] MOUNTS WITH NO. 10 SCREW (2 REQ'D) .41 [10.4] A .38 .56 [14.1] NO.8-32 N C-2 STUD SECTION A-A [9.5] .78 [19.8]

mm = dim X 25.4

17TB SERIES

6.50 [165.1] .25 [6.4] 6.00 [152.4] .53 #6-32 NC-2 INSERT A #8-32 NC-2 MOUNTS WITH #10 SCREW (2 REQ'D) .81 [20.6] STUD 1.81 [46.0] .44 [11.1] [13.5] #6-32 x 3/16 BD HD SCREW

(A-A-59125/21) / (MIL-T-55164/21)
Double Row, Front Connection Number of Terminals Type Dim. A Dim. B
w/stud w/o stud connectors connectors

Nuts 10

Military/Navy Terminal Blocks

17 TB 10F

10

20

6.50

6.00

R .11 [2.8] .28 [7.1]

A .41 [10.4]

6.00 .56 [14.3] .44 [11.1] .38 [9.5] .78 [19.8] [152.4] DESIGNATION PLATE FOR 17TB BOARD. (MAT'L TYPE GME)

.06 [1.6]

mm = dim X 25.4

25TB SERIES
Type 25 TB 02F 25 TB 05F 25 TB 06F 25 TB 07F 25 TB 09F 25 TB 10F 25 TB 12F

(A-A-59125/23) / (MIL-T-55164/23)
Single Row, Front Connection # of Term. Dim. A Dim. B 2 1.38 1.06 5 2.31 2.00 6 2.63 2.31 7 2.94 2.63 9 3.56 3.25 10 3.88 3.56 12 4.50 4.19 Nuts 2 5 6 7 9 10 12

.16 [4.0]

A B .31 [7.9]
1 2 3 4 5

MOUNTS WITH #6 SCREW (2 REQ'D) .22 [5.6]

.19 [4.8] .25 [6.3] .35 [8.8]

.15 [3.8]

.44 [11.1] #4-40 NC-2 STUD

.25 [6.4] .38 [9.5]

25TBHT also available

mm = dim X 25.4

26TB SERIES

A .16 [4.0] .25 [6.4]


2 3 4 5 6 7 8 1 9

MOUNTS WITH #6 SCREW (2 REQ'D) .31 [7.9]


10 11 12

(A-A-59125/24) / (MIL-T-55164/24)
Double Row, Linked Front Connection # of Term. Type 26 26 26 26 TB TB TB TB 06F 08F 10F 12F
w/stud w/o stud connectors connectors

.22 [5.6] .67 [17.0] .38 [9.6] #4-40 NC-2 STUD .25 [6.4] .38 [9.5]

Dim. A 2.63 3.25 3.88 4.50

Dim. B 2.31 2.94 3.56 4.19

Nuts 12 16 20 24

6 8 10 12

12 16 20 24

.15 [3.8]

.19 [4.8]

.35 [8.9]

26TBHT also available

mm = dim X 25.4

For electronic drawings or 2D/3D CAD data, send request to drawings@marathonsp.com

Datasheets available at marathonsp.com

141

Index
Catalog #
0987 RZ Series 100 Series 10SM Series 10TB-F Series 1100 Series 1103P 11TB-F Series 1200 Series 132X122 (CH) 132X422 (CH) 132X474 (CH) 132X570 (CH) 132X572 (CH) 132X574 (CH) 132X580 (CH) 132X970 (CH) 132X972 (CH) 133X126 (CH) 133X270 (CH) 133X271 (CH) 133X272 (CH) 133X273 (CH) 133X280 (CH) 133X281 (CH) 133X305 (CH) 133X320 (CH) 133X360 (CH) 133X552 (CH) 133X553 (CH) 133X554 (CH) 133X555 (CH) 133X558 (CH) 133X559 (CH) 133X563 (CH) 133X564 (CH) 133X565 (CH) 133X575 (CH) 133X585 (CH) 133X587 (CH) 133X588 (CH) 133X595 (CH) 133X596 (CH) 133X597 (CH) 133X598 (CH) 133X611 (CH) 133X953 (CH) 133X955 (CH) 135 Series 140X303 140X401 140X402 140X404 140X410

Page #
72 78 24 140 70 71 140 71 50 50 53 44 48 53 44 44 48 49 54 54 54 54 54 54 49 49 49 45 45 44 45 53 53 50 50 46 46 46 46 46 46 47 47 47 51 46 45 39 48 44 44 44 44

Catalog #
140X801 141X200 141X201 141X202 141X203 141X205 141X300 141X301 141X400 141X403 142X121 142X122 142X123 142X411 142X552 142X553 142X570 142X572 142X574 142X970 143X123 143X124 143X126 143X306 143X552 143X553 143X554 143X555 143X559 143X561 143X563 143X587 143X590 143X953 143X955 144X122 144X401 144X551 144X553 144X557 144X560 144X569 144X575 144X614 1453401 145X129 145X282 145X301 145X408 145X411 145X552 145X573 145X579

Page #
48 52 52 52 53 52 48 52 44 44 48 50 50 52 48 52 44 48 53 44 48 48 48 49 45 45 45 45 53 50 50 46 53 45 45 50 45 46 50 49 45 53 53 51 47 49 54 49 47 47 46 50 46

Catalog #

Page #

145X583 50 145X586 47 145X587 47 145X592 47 145X594 46 145X599 53 145X606 51 145X610 53 145X613 51 145X986 47 145X992 47 1500 Series 74 15TB-F Series 141 1600 Series 75 1690 GP Series 99 - 100 16TB-F Series 141 1700 Series 76 17TB-F Series 141 1MS Series 29 200 Series 79 2590 GP Series 101 25TB-F Series 141 2690 GP Series 102 - 103 26TB-F Series 141 300 Series 80 3TB-F Series 139 3/4 ST (Solder Term. Lugs) 106 37TB-B Series 132 37TB-F Series 133 37TBLD 136 37TBLS 136 38TB-F Series 133 38TBLD 136 38TBLS 136 39TB-F Series 134 39TBLD 39TBLS 400 Series 40TB-B Series 40TB-F Series 410 GP Series 411 GP Series 411-1904 41TB-F Series 42TB-F Series 4TB-F Series 599 GP Series 599-2002 599-2004 599-2020 599-2021 5TB-F Series 600-2004 136 136 81 132 134 82 95 109 135 135 139 96 109 109 109 109 139 109

142

Datasheets available at marathonsp.com

Index
Catalog #
600A-2002 600A GP Series 600 GP Series 601-2102 601-2104 601-2108 601 GP Series 602-2202 602 GP Series 603-2302 603 GP Series 604-2402 604 GP Series 605-2502 605 GP Series 621 RZ Series 649 Series (Fanning 650 Series (Fanning 651 Series (Fanning 652 Series (Fanning 699-2102 699-2104 699-2120 699-2121 699 GP Series 670A GP Series 670A RZ Series 671 GP Series 671 RZ Series 672 GP Series 672 RZ Series 6CC30A Series 6F30A Series 6F200A Series 6F600A Series 6F60A Series 6G38 Series 6G44 Series 6H12 Series 6J200A Series 6J30A Series 6J400A Series 6J600A Series 6J60A Series 6M30A Series 6R100A Series 6R200A Series 6R30A Series 6R400A Series 6R600A Series 6R60A Series 6SC30A Series 6SJ Series

Page #
109 84 83 109 109 109 85 109 86 109 87 109 88 109 89 90 Strips) 108 Strips) 108 Strips) 108 Strips) 108 109 109 109 109 97 78 91 79 92 80 93 26 11 11 11 11 117 - 118 119 120 19 19 19 19 19 23 12 12 12 12 12 12 27 22

Catalog #

Page #

Catalog #
MIKSI5 MIKTS4 Military Marking Strips Power Block Covers R100A Series R200A Series R30A Series R400A Series R600A Series R60A Series R6CC60 Series R6F100A Series R6F30A Series R6F400A Series R6F60A Series R6J100A Series R6J30A Series R6J60A Series R6T30A Series R6T60A Series RF100A Series RF30A Series RF400A Series RF60A Series RG15A Series RG20A Series RG30A Series RH Series (Fuse Panels) RJ, RJS Jumpers RT30A Series RT60A Series SCCR SPB (Straddle Plate) ST (Solder Terminal Lugs) ST710 Series ST715S1902/Cover ST722B Series ST722E Series ST722S Series ST723B38 Series ST750 Series (Motor blks) ST755 Series (Motor blks) STSF T100A Series T200A Series T30A Series T400A Series T600A Series T60A Series Wire Clamp Y, YSY, Z

Page #
129 128 137 58 12 12 12 12 12 12 26 11 11 11 11 19 19 19 16 16 11 11 11 11 28 28 28 9 - 10 107 16 16 36 107 106 66 64 61 63 62 65 67 - 68 67 - 68 32 16 16 16 16 16 16 107 106

6SM30A Series 24 6T100A 16 6T200A 16 6T30A 16 6T400A 16 6T600A 16 6TB-F Series 139 6W30A Series 25, 121 799 GP Series 96 7TB-F Series 140 800A GP Series 84 801 GP Series 85 802 GP Series 86 812 GP Series 98 812-2202 109 812-2204 109 899 GP Series 97 8TB-F Series 140 912 GP Series 98 985 Series 73 9TB-F Series 140 C7220X (Feed Thru covers) 60 Custom Products 148 DIN Rail Adapters 35 DIN Rail Labels (MSH) 130 EPB Series (Listed) 40 - 41 EPB Series (Recognized) 42 F200A Series 11 F30A Series 11 F600A Series 11 F60A Series 11 Feeder Spacing Adapter Kits 36 Flex Wire 5-6 FPB23 Series 37 - 38 FPB33 Series 37 - 38 FSM Series 30 Fuse Holder Covers/Puller 33 - 34 Fuse Holder with BD 31 G15A Series 28 G20A Series 28 G30A Series 28 Grounding Lugs 59 J-JS Jumpers (LL) 107 Kliptite (KT)/Quick Connect 104 - 105 Marking Strips & Covers 110 - 115 MIK10 125 MIK16 126 MIK25 127 MIK3 123 MIK5 124 MIKE10 129 MIKE16 129 MIKE4 129

Datasheets available at marathonsp.com

143

Terms and Conditions


ALL QUOTATIONS ARE MADE AND ALL ORDERS ARE ACCEPTED BY MARATHON SPECIAL PRODUCTS CORPORATION SUBJECT ONLY TO THESE TERMS AND CONDITIONS. 5. TAXES In addition to any prices, Buyer shall pay the amount of any present or future manufacturers tax, retailers occupation tax, use tax, sales tax, excise tax, duty, custom, inspections or testing fee, or any other tax, fee or charge of any nature whatsoever imposed by any government authority, on or measured by the transaction between Marathon and Buyer. In the event Marathon is required to pay any such tax, fee or charge, Buyer shall reimburse Marathon therefor, or, in lieu of such payment, Buyer shall provide Marathon at the time the order is submitted with an exemption certificate or other document acceptable to the authority imposing such tax, fee or charge. 6. TERMS OF PAYMENT All orders are subject to the approval of Marathon at its home office. Terms of payment are cash in full no later than thirty (30) days from date of shipment, without discount. If, during the period of performance of an order, the financial condition of Buyer is determined by Marathon not to justify the terms of payment specified, Marathon may demand full or partial payment in advance before proceeding with the work, or satisfactory security or guarantees that invoices will be promptly paid when due, or, at its option without prejudice to other lawful remedies, may defer delivery or cancel this contract If delivery is deferred, the equipment may be stored as provided in Section 9 hereof and Marathon may submit a new estimate of cost for completion based upon prevailing conditions. If Buyer defaults in any payment when due, or in the event any voluntary or involuntary bankruptcy or insolvency proceedings involving Buyer are initiated by or against Buyer, then the whole contract price shall immediately become due and payable upon demand, or Marathon, at its option without prejudice to its other lawful remedies, may defer delivery or cancel this contract Prorata payments shall become due as shipments are made. If shipments are delayed by the Buyer for any cause, payments shall become due from the date on which Marathon is prepared to make shipment and storage shall be at the Buyers risk and expense as provided in Section 9 hereof. If manufacture is delayed by the Buyer for any cause, a Partial payment based upon the proportion of the order completed shall become due from the date on which Marathon is notified of the delay. 7. DELIVERY; RISK OF LOSS All sales are F 0.B. Marathons plant or other point of shipment designated by Marathon. Shipping dates are estimates only which are not guaranteed and are based upon prompt receipt from Buyer of all necessary shipping and other information, Marathon reserves the right to make delivery in installments. All installments to be separately invoiced and paid for by Buyer when due per invoice, without regard to subsequent deliveries. Delivery of equipment to a commercial carrier at Marathons plant or other loading point shall constitute delivery to Buyer, and any risk of loss and further cost and responsibility thereafter for claims, delivery, loss or damage, including if applicable, placement and storage shall be borne by Buyer. When equipment is delivered by Marathons truck, unloading at Buyers dock shall constitute delivery to Buyer. Claims for shortages or other errors in delivery must be made in writing to Marathon within ten (10) days after receipt of shipment and failure to give such notice shall constitute unqualified acceptance and a waiver of all such claims by Buyer. Claims for loss or damage to equipment in transit by common carrier must be made to the carrier and not to Marathon. Freight and handling charges by Marathon may not reflect actual freight charges prepaid to the carrier by Marathon due to incentive discounts earned by Marathon based upon Marathons aggregate volume of freight tendered to a carrier or when a carrier must be used which charges a rate which is different than the rate upon which Marathons freight and handling charges were based. When shipments are delivered in Marathons private trucks, Buyer will be charged an amount approximating the prevailing common carrier rate. 8. EXCUSABLE DELAYS FORCE MAJEURE Marathon shall not be liable for any loss or damage as a result of Marathons delay in or failure of delivery or installation due to (i) any cause beyond Marathons reasonable control, (ii) an act of God, act of the Buyer, embargo or other governmental act, authority regulation or request, fire, theft, accident, strike, slow-down or other labor disturbance, war, riot, delay in transportation, or (iii) inability to obtain necessary labor, materials, components or facilities. Should any of the aforementioned events of force majeure occur, Marathon at its option, may cancel Buyers order with respect to any undelivered equipment or extend the delivery date for a period equal to the time lost because of delay. Notice of such election shall be given promptly to Buyer. In the event Marathon elects to so cancel the order Marathon shall be released of and from all liability for failure to deliver the equipment including, but not limited to any and all claims on behalf of Buyer for lost profits or any other claim of any nature which Buyer might have. If shipping or progress of the work is delayed or interrupted by Buyer, directly or indirectly, Buyer shall pay Marathon for all additional charges resulting therefrom. 9. STORAGE If the equipment is not shipped within thirty (30) days after notification has been made to Buyer that it is ready for shipping, for any reason beyond Marathons control, including Buyers failure to give shipping instructions, Marathon may store the equipment at Buyers risk and expense in a warehouse or upon Marathons premises, and Buyer shall pay all handling, transportation and storage costs at the prevailing commercial rates promptly following Marathons submission of invoices for such costs. 1O. WARRANTIES TO DISTRIBUTORS AND INDUSTRIAL OR COMMERCIAL CUSTOMERS This warranty is extended only to Marathons distributors and industrial or commercial customers and does not apply to consumer purchasers. Warranty Period - Marathon warrants products manufactured by it to be free from defects in materials and workmanship and to conform to Marathons written specifications for a period of twelve (12) months from date of first use or eighteen (18) months from date of manufacture whichever period shall expire first. Warranty Remedies - If prior to expiration of the foregoing warranty period, any product shall be proved to Marathons satisfaction to be defective or nonconforming, Marathon will repair or replace such defective equipment or components thereof. F.O.B. Marathons plant or other destination designated by Marathon or will refund or credit by Marathon, the purchase price paid therefor by Buyer, at Marathons sole option. Buyers exclusive remedy and Marathons sole obligation under this warranty shall be limited to such repair or replacement, F.O.B. Marathons plant or other destination designated by Marathon or refund or credit by Marathon, and shall be conditioned upon Marathons receiving written notice of any defect within sixty (60) days after it was discovered or by reasonable care should have been discovered. In no event shall Marathons liability for such defective or nonconforming products exceed the purchase price paid by Buyer therefore. Exclusions - This warranty does not (i) cover shipping expenses to and from Marathons factory or other destination designated by Marathon for repair or replacement of defective equipment or any tax, duty, custom, inspection or testing fee, or any other charge of any nature related thereto, nor does it cover the costs of removing defective equipment or reinstalling repaired or replaced equipment, (ii) apply and shall be void with respect to equipment operated in excess of rated capacity or otherwise not in accordance with installation, maintenance or operating instructions or requirements, to equipment repaired or altered by

MODIFICATIONS OF SALES TERMS Any Terms and Conditions contained in any purchase order or other form of communication from Marathons customers which are additional or different from these Terms and Conditions shall be deemed rejected by Marathon unless expressly accepted in writing by Marathon. In general, no modification, amendment, waiver or other change of any of these Terms and Conditions and those contained on the reverse side hereof and/or in attachments hereto (Terms and Conditions), or of any of Marathons rights or remedies thereunder, shall be binding on Marathon unless expressly accepted in writing by Marathons authorized officers at Marathons home office. No course of dealing, usage of trade or course of performance shall be relevant to explain or supplement any of these Terms and Conditions. In cases of conflict between the Terms and Conditions printed on this page and those contained on the face side or in attachment hereto, the latter shall control. If any document issued by any party hereto is sent by facsimile or another form of electronic document transmission, the parties hereto agree that (a) the copy of any such document printed on the facsimile machine or printer of the recipient thereof is a counterpart original copy thereof and is a writing, (b) delivery of any such other form of electronic document to the recipient thereof by facsimile or such other form of electronic document transmission is authorized by the recipient thereof and is legally sufficient for all purposes as if delivered by United States mail, (c) the typewritten name of an authorized agent of the party sending such document on any such document is sufficient as a signature thereon and behalf of such party and the intent of such signature is to authenticate the writing, and (d) an electronically stored and reproduced copy of any such document shall be deemed to be legally sufficient evidence of the terms of such document for all purposes. 2. ACCEPTANCE OF ORDERS Acceptance by Marathon of Buyers purchase order(s) is expressly conditioned upon Buyers assent to these Terms and Conditions. Buyer will be deemed to have assented to such Terms and Conditions unless Marathon receives written notice of any objection within fifteen (15) days after Buyers receipt of this form and in all events prior to any delivery or other performance by Marathon of Buyers order. 3. QUOTATIONS Quotations by Marathon shall be deemed to be offers by Marathon to sell the equipment described therein subject to these Terms and Conditions, and acceptance of such offers is expressly limited to acceptance by Buyer of all of these Terms and Conditions within thirty (30) days from the date of the quotation. Purchase orders submitted by Buyer for the equipment quoted by Marathon shall be subject to and will be deemed to constitute acceptance of these Terms and Conditions. All purchase orders will be subject to approval by Marathon at Marathons home office. 4. PRICES: PRICE CHANGES All prices are net F.O.B. shipping point and are subject to change without notice. In the event of a change in Marathons prices, the price for equipment unshipped will be the price in effect on the date of shipment. If Marathons quoted price was based on delivery to and acceptance by Buyer of a specified quantity of equipment, such price shall be subject to adjustment if Buyer does not accept the quantity at the times specified in Marathons quotation, and Buyer will be invoiced at Marathons standard price without quantity discounts, if any, for the quantity of equipment actually accepted by Buyer.

1.

144

Datasheets available at marathonsp.com

Terms and Conditions


others than Marathon or Marathons authorized service agencies, or to equipment which was subjected to abuse, negligence, misuse, misapplication, accident, damages by circumstances beyond Marathons control, to improper installation (if by others than Marathon), operation, maintenance or storage, or to other than normal use or service, and (iii) apply to equipment or components not manufactured by Marathon. With respect to equipment or components not manufactured by Marathon, Marathons warranty obligations shall in all respects conform and be limited to the warranty actually extended to Marathon by its suppliers but in no event shall Marathons obligations be greater than those provided under Marathons warranty set forth in this Section 10. THE FOREGOING WARRANTIES ARE IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES (EXCEPT TITLE), INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. NO EMPLOYEE, REPRESENTATIVE, OR AGENT OF MARATHON OTHER THAN AN OFFICER OF MARATHON IS AUTHORIZED TO ALTER OR MODIFY ANY PROVISION OF THIS SECTION 10 OR TO MAKE ANY GUARANTEE, WARRANTY, OR REPRESENTATION, EXPRESS OR IMPLIED, ORALLY OR IN WRITING, WHICH IS CONTRARY TO THE FOREGOING. Any description of the equipment, whether in writing or made orally by Marathon or Marathons agent, specifications, samples, models, bulletins, drawings, diagrams, engineering sheets or similar materials used in connection with Buyers order are for the sole purpose of identifying the equipment and shall not be construed as an express warranty. Any suggestions by Marathon or Marathons agents regarding use, application or suitability of the equipment shall not be construed as an express warranty unless confirmed to be such in writing by Marathons authorized officer at Marathons home office. 11. LIMITATIONS OF LIABILITY; CONSEQUENTIAL DAMAGES Nuclear Use Disclaimer - Equipment sold by Marathon is not intended for use in connection with any nuclear facility or activity. If so used Marathon disclaims all liability for any nuclear damage, injury or contamination, and Buyer shall indemnify and hold Marathon, its officers, agents, employees, successors, assigns, and customers harmless from and against any and all losses, damages or expenses of whatever form or nature (including attorneys fees and other costs of defending any action) which they or any of them may sustain or incur whether as a result of breach of contract, warranty, tort (including negligence) or otherwise, by reason of such use. Consequential Damage Disclaimer - Marathons liability with respect to equipment proved to its satisfaction to be detective within the warranty period shall be limited to repair, replacement or refund as provided in Section 10 hereof and in no event shall Marathons liability exceed the purchase price of the equipment involved. Marathon shall not be subject to any other obligations or liabilities, whether arising out of breach of contract, warranty, tort (including negligence) or other theories of law, with respect to equipment sold or services rendered by Marathon, or any undertakings, acts or omissions relating thereto. Without limiting the generality of the foregoing, Marathon specifically disclaims any liability for property or personal injury damages, penalties, special or punitive damages, damages for lost profits or revenues, loss of use of equipment or any associated equipment, cost of capital, cost of substitute products, facilities or services, down-time, shut-down, or slow-down costs, or for any other types of economic loss, and for claims of Buyers customers for any such damages. MARATHON SHALL NOT BE LIABLE FOR AND DISCLAIMS ALL CONSEQUENTIAL, INCIDENTAL AND CONTINGENT DAMAGES WHATSOEVER. EVEN IF THE REPAIR OR REPLACEMENT REMEDY SHALL BE DEEMED TO HAVE FAILED OF ITS ESSENTIAL PURPOSE UNDER SECTION 2-719 OF THE UNIFORM COMMERCIAL CODE, MARATHON SHALL HAVE NO LIABILITY TO BUYER FOR CONSEQUENTIAL DAMAGES, SUCH AS LOST PROFITS, LOST REVENUE, DAMAGE TO OTHER EQUIPMENT OR LIABILITY OR INJURY TO A THIRD PARTY. 12. INDEMNIFICATION BY BUYER Buyer shall indemnify, hold harmless, and defend Marathon and Marathons employees and agents from and against any and all damages, liability, claims, losses, and expenses (including reasonable attorneys fees, court costs, and out-of-pocket expenses) arising out of or resulting in any way from claims by customers of Buyer or third parties against Marathon alleging a breach of contract or warranty by Marathon to the extent that such damages, liability, claims, losses, and expenses which may be payable by Marathon to Buyer pursuant to and as limited by Marathons warranty and damage obligations as contained in Sections 10 and 11 hereof so as to effectively limit Marathons obligations to customers of Buyer or third parties to those set forth in Sections 10 and 11 hereof. 13. PATENT INDEMNIFICATION Marathon will at its own expense, defend or settle any suits that may be instituted against Buyer for alleged infringement by the equipment of any United States patent, provided that (a) such alleged infringements consists of the use of the equipment for any of the purposes for which such equipment was sold, (b) Buyer shall have made all payments for such equipment then due hereunder, (c) Buyer shall give Marathon immediate notice in writing of any such suit and transmit to Marathon immediately upon receipt all processes and papers served upon Buyer, and (d) Buyer shall permit Marathon through its counsel, either in the name of Buyer or in the name of Marathon, to defend such suit(s) and give all needed information, assistance and authority to enable Marathon to do so. In case of a final award of damages in any such suit, Marathon will pay such award but will not be responsible for any compromise or settlement made without its written consent. In case the equipment itself is in such suit held to infringe any valid patent issued in the United States and its use enjoined, or in the event of a settlement or compromise approved by Marathon which shall preclude future use of the equipment sold to Buyer hereunder, Marathon shall, at its own expense and, at its sole option, either (a) procure rights to continue using such equipment, (b) modify the equipment to render it noninfringing, (c) replace the equipment with noninfringing equipment, or (d) refund the purchase price paid by Buyer for the equipment after return of the equipment to Marathon. Notwithstanding the foregoing, Marathon shall not be held responsible for infringements of combination or process patents covering the use of equipment in combination with other goods or materials not furnished by Marathon. The foregoing states the entire liability of Marathon for patent infringement and IN NO EVENT SHALL MARATHON BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES ATTRIBUTABLE TO AN INFRINGEMENT nor for infringement based on the use of the equipment for a purpose other than that for which sold by Marathon. As to any equipment furnished by Marathon to Buyer manufactured in accordance with designs proposed or furnished by Buyer or any claim of contributory infringement resulting from the use or resale by Buyer of equipment sold hereunder, Buyer shall indemnify Marathon against any award made against Marathon for any patent, trademark or copyright infringements, including attorneys fees and defense costs. 14. SECURITY AGREEMENT AND FINANCING STATEMENTS To secure payment of the purchase price and of all monies which may be due hereunder, and performance of all of Buyers obligations hereunder, Buyer hereby grants to Marathon a security interest in all equipment sold by Marathon, and agrees to execute such other Security Agreements and Financing Statements as Marathon may reasonably request. 15. INSURANCE Until payment in full of the purchase price, Buyer shall maintain insurance covering all equipment sold by Marathon to Buyer in such amounts and against such risks as is customary by companies engaged in the same or similar business and similarly located, and shall, upon Marathons request, furnish evidence of such insurance satisfactory to Marathon. 16. DRAWINGS: OTHER DESIGN DATA All specifications, drawings, design, data, information, ideas, methods, patterns and/or inventions made, conceived, developed or acquired by Marathon in connection with procuring and/or executing Buyers order will vest in and inure to Marathons sole benefit notwithstanding any changes therefor which may have been or may be imposed by Marathon. Buyer shall not give, loan, exhibit, sell or transfer to any person not then employed by Buyer and authorized to receive such information, or to any organization or entity, any drawing, photograph, or specification furnished by Marathon or reproduction thereof which may enable such person, organization or entity to furnish similar goods or parts therefor. 17. RETURN OF EQUIPMENT No equipment or part shall be returned to Marathon without written authorization and shipping instructions first having been obtained from Marathon. 18. ASSIGNMENT None of the Buyers rights under any order shall be assigned by the Buyer to any other person, whether by operation of law or otherwise, without Marathons prior written approval. Marathon may, without the necessity of obtaining Buyers prior written consent, subcontract the production of all or any portion of the equipment. 19. CANCELLATION No order submitted to Marathon may be cancelled by Buyer without the prior written consent of Marathon, which consent will at all times be conditioned on Buyers agreement to pay Marathons cancellation charge. For finished equipment which in Marathons judgment is readily resalable to others, the cancellation charge shall be 15% of the invoice price of the equipment. For all other cancellations the cancellation charge shall amount to all costs and expenses incurred by Marathon and arising out of or in connection with the Buyers order, net of recoverability, but in no event less than 10% of the invoice price of the equipment or more than the invoice price. 20. GENERAL Governing Law - These Terms and Conditions, and the contract of sale between Marathon and Buyer, shall be governed by and construed in accordance with the internal laws of the State of Ohio. Marathon and Buyer hereby agree that any legal action deemed necessary by either party hereto shall be brought in the Circuit Court in and for Wood County, Ohio and hereby consent to the personal jurisdiction of such court in any such action over the parties hereto. The rights and obligations of Marathon and Buyer shall not be governed by the provisions of the United Nations Convention on Contracts for the International Sales of Goods. Attorneys Fees - Buyer agrees to pay all of Sellers costs and expenses of collection and related litigation, including but not limited to attorneys fees and costs. Salvatory Clause - The invalidity, in whole or in part, of any of the provisions of these Terms and Conditions, shall not affect the enforceability of any of the other provisions thereof. Applicability - The Terms and Conditions as stated herein are applicable as of the date of this printing and until such time as changed by Marathon. Revised, January 2003

Datasheets available at marathonsp.com

145

IMPORTANT INFORMATION PLEASE READ CAREFULLY


The following DANGER, WARNING and CAUTION information is supplied to you for your protection and to provide you with many years of trouble free and safe operation of your Marathon Special Products components.

! DANGER

Devices sold by Marathon Special Products provide for interconnection of electrical circuits and as such are, or can be, points of live electrical contact. It is the responsibility of the Buyer or user to ensure through the use of enclosures, insulation, engineering controls, or other means in the application, that the wiring device is protected from intentional or accidental contact in an energized condition. Failure to do so can create the potential for electrical shock and associated serious injury. Only qualified personnel should install and troubleshoot electrical products due to the potential for serious injury related to electrical shock. Make certain that the power supply is disconnected and/or locked out before attempting to install, remove or service components.

! WARNING

Connection tightness is critical to electrical performance. Buyer, user, or installer must always ensure that the proper screw torque is applied and maintained. Buyer or user must ensure that proper clearances are maintained between energized electrical components and all other devices including but not limited to the enclosure and mounting mechanism.

! CAUTION

Install and ground per local and national code. Buyer shall be solely responsible for determining the adequacy of the product for any and all uses to which Buyer shall apply the product. Buyer must ensure that the application of the device conforms to all standards, codes, policies or practices that govern or apply to their equipment or application. Marathon Special Products uses design parameters, materials, and construction methods intended to meet the standards noted in the engineering catalog, with specific suitability of use and restrictions as noted in the appropriate agency files. The application by Buyer shall not be subject to any implied warranty of fitness for a particular purpose. Products in this catalog are tested and listed with various standards agencies. They will meet or exceed all performance guidelines as tested and qualified. Buyer or user must check that applications do not exceed rated capacities of voltage and amperage and that appropriate wiring practices are followed. Products are intended for use in an as sold condition. Modification of components can affect performance and ratings and subsequently the safety of the component system. Buyer or user assumes liability for component modification. Electrical products in this catalog are designed for use in appropriate enclosures. Buyer or user is responsible to ensure that appropriate environmental control is designed into the application.

In the event of the resale of any goods, in whatever form, Resellers/Buyers will include the following language in a conspicuous place and in a conspicuous manner in a written agreement covering such sale: The manufacturer makes no warranties or representations, express or implied, by operation of law or otherwise, as to the merchantability or fitness for a particular purpose of the goods sold hereunder. Buyer acknowledges that it alone has determined the goods purchased hereunder will suitably meet the requirements of their intended use. In no event will the manufacturer be liable for consequential, incidental or other damages. Even if the repair or replacement remedy shall be deemed to have failed of its essential purpose under section 2-719 of the Uniform Commercial Code, the manufacturer shall have no liability to Buyer for consequential damages. Resellers/Buyers agree to also include this entire document including the dangers,warnings and cautions listed above in a conspicuous place and in a conspicuous manner in writing to instruct users on the safe usage of the product. This information should be read together with all other printed information supplied by Marathon Special Products. For more information contact: Marathon Special Products, Subsidiary of Regal-Beloit Corporation, 13300 Van Camp Road, Bowling Green, OH. 43402, Phone: 419-352-8441, Fax: 419-352-0875, Website: www.marathonsp.com

146

Datasheets available at marathonsp.com

Notes

Datasheets available at marathonsp.com

147

Custom Products

If it involves wire connections, we can engineer the solution and manufacture it for you. Whether its a modification to a current product or a custom design, let Marathon Special Products provide the solution to your application needs. Our 75+ years of experience in designing, engineering and manufacturing electrical wire connection devices gives us the design expertise and manufacturing capabilities involving metal stampings, fabrication, thermoplastic and thermoset injection molding and components assembly. Through the use of the latest 3D solid modeling and finite element analysis, we will convert concepts into design for production; thus, providing a cost competitive solution to meet your requirements in a timely manner. In our UL approved test lab, products are evaluated to ensure compliance with safety agency standards including UL, CSA and CE. In addition, Marathons products are RoHS compliant. ISO 9001 certificated processes and controls assure delivery of quality products with continuous improvements. Marathon Special Products will be pleased to propose a solution to meet your engineering, Agency, manufacturing and assembly requirements. Give us a call today at (419) 352-8441, send an email to marketing@marathonsp.com, or visit www.marathonsp.com to learn more about how Marathon Special Products can provide that special application solution for your company.

148

Datasheets available at marathonsp.com

The Right Product For Your Needs


Power Blocks Fuse Holders

MARATHON SPECIAL PRODUCTS ENGINEERING CATALOG

Terminal Blocks

13300 Van Camp Road P.O. Box 468 Bowling Green, OH 43402 Phone: (419) 352-8441 Fax: (800) 515-7151 or (419) 352-0875

www.marathonsp.com
6380K-NP/5K/07-09/DBH

You might also like