nonVSD Elektronikon
From following serial numbers onwards: GA90-110-132-160 (W): GA200-250-315 (W): GR110-132-160-200 (W): ZA3-4-5-6: ZE3-4: ZT15-18-22-30-37-45: ZR30-37-45: ZT55-75-90: ZR55-75-90: ZT110-132-145-160-200-250-275: ZR110-132-145-160-200-250-275-300-315-355400-425-450-500-630-750: AIF-078 300 AIF-078 302 AIF-078 406 AIF-078 954 AIF-078 954 AII-702 000 AII-702 000 AIF-077 519 AIF-077 519 AIF-079 599 AIF-079 599
This manual must be used together with the relevant instruction books of the compressors.
Copyright 2003, Atlas Copco Airpower n.v., Antwerp, Belgium. Any unauthorized use or copying of the contents or any part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings. This instruction book meets the requirements for instructions specified by the machinery directive 98/37/EC and is valid for CE as well as non-CE labelled machines
No. 2920 1478 01 Replaces 2920 1478 00 Registration code: APC G > 90/'99 / 38 / 958 APC Z55-90 / 38 / 995 APC Z<55 + VSD / 38 / 394 APC ZE/ZA 3-6 / 38 / 993 APC ZR/ZT110-275 / 38 / 972 APC ZR300-750 / 38 / 983 www.atlascopco.com
2003-04
2920 1478 01
Instruction book
1 General description............................................................................................................................ 4 1.1 Controlling the compressor............................................................................................................ 4 1.2 Protecting the compressor............................................................................................................. 4 1.2.1 Shut-down and fan motor overload ......................................................................................... 4 1.2.2 Shut-down warning.................................................................................................................. 5 1.2.3 Warning ................................................................................................................................... 5 1.3 Service warning ............................................................................................................................. 5 1.4 Automatic restart after voltage failure ............................................................................................ 5 1.5 Permissive start ............................................................................................................................. 5 1.6 Start commands during programmed stop time and minimum stop time ...................................... 5 2 Control panel (Fig. 2.1)....................................................................................................................... 6 3 Display - keys...................................................................................................................................... 7 3.1 Display (3-Fig. 2.1)......................................................................................................................... 7 3.2 Scroll keys (4-Fig. 2.1) ................................................................................................................... 7 3.3 Tabulator key (5-Fig. 2.1) .............................................................................................................. 7 3.4 Function keys (9-Fig. 2.1) .............................................................................................................. 7 4 Menu-driven control programs ......................................................................................................... 9 4.1 Function of control programs ......................................................................................................... 9 4.2 Main screen ................................................................................................................................... 9 4.3 Calling up other menus ................................................................................................................ 10 5 Quick look at actual compressor status ........................................................................................ 19 6 Status data menu.............................................................................................................................. 20 6.1 No message exists....................................................................................................................... 20 6.2 A shut-down message exists ....................................................................................................... 20 6.3 A shut-down warning message exists ......................................................................................... 21 6.4 A service warning message exists............................................................................................... 22 6.5 A warning message exists ........................................................................................................... 22 7 Measured data menu........................................................................................................................ 23 8 Counters menu ................................................................................................................................. 23 9 Test menu.......................................................................................................................................... 24 10 Modify parameters.......................................................................................................................... 24 10.1 Modifying parameters ................................................................................................................ 24 11 Modifying protection settings ....................................................................................................... 26 11.1 Modifying settings for compressor element temperature........................................................... 26 12 Modifying service plans................................................................................................................. 27 13 Programming Clock function ........................................................................................................ 28 13.1 Programming start/stop/pressure band commands................................................................... 28 13.2 To activate/deactivate the timer................................................................................................. 29 13.3 To modify a command ............................................................................................................... 29 13.4 To add a command .................................................................................................................... 30 13.5 To delete a command ................................................................................................................ 31 14 Configuration menu ....................................................................................................................... 33 14.1 Programming compressor control modes.................................................................................. 33 15 Service menu .................................................................................................................................. 34 16 Saved data menu ............................................................................................................................ 35 17 Programmable settings.................................................................................................................. 36 17.1 GA90 (W) up to GA315 (W)....................................................................................................... 36 17.1.1 Parameters.......................................................................................................................... 36 17.1.2 Protections .......................................................................................................................... 38 17.1.3 Service settings ................................................................................................................... 39 17.2 GR110 (W) up to GR200 (W) .................................................................................................... 40 17.2.1 Parameters.......................................................................................................................... 40 17.2.2 Protections .......................................................................................................................... 41 17.2.3 Service settings ................................................................................................................... 42 17.3 ZE/ZA 3-4................................................................................................................................... 43 17.3.1 Parameters.......................................................................................................................... 43 17.3.2 Protections .......................................................................................................................... 45 17.3.3 Service settings ................................................................................................................... 46 17.4 ZA 5-6 ........................................................................................................................................ 47
2920 1478 01
Instruction book
17.4.1 Parameters.......................................................................................................................... 47 17.4.2 Protections .......................................................................................................................... 50 17.4.3 Service settings ................................................................................................................... 51 17.5 ZT15 up to ZT45 / ZR30 up to ZR45 ......................................................................................... 52 17.5.1 Parameters.......................................................................................................................... 52 17.5.2 Protections .......................................................................................................................... 52 17.5.3 Service settings ................................................................................................................... 53 17.6 ZT55 up to ZT90 / ZR55 up to ZR90 ......................................................................................... 54 17.6.1 Parameters.......................................................................................................................... 54 17.6.2 Protections .......................................................................................................................... 55 17.6.3 Service settings ................................................................................................................... 56 17.7 ZT110 up to ZT275 / ZR110 up to ZR750 ................................................................................. 57 17.7.1 Parameters.......................................................................................................................... 57 17.7.2 Protections .......................................................................................................................... 58 17.7.3 Service settings ................................................................................................................... 59 17.8 Notes chapter 17........................................................................................................................ 60
2920 1478 01
Instruction book
1 General description
In general, the regulator has following functions: controlling the compressor protecting the compressor monitoring components subject to service automatic restart after voltage failure (made inactive) permissive start (GA/GR compressors)
1) 2)
For ZE and ZA without full-load/no-load regulator, the settings for unloading and loading the compressor are not programmable; consequently, these parameters are not taken into account. GA90/315 and GR110/200 have an unloading time of 30 seconds, for Z compressors this period is 3 seconds. If a compressor with 30 seconds unloading time was running at the moment of manually stopping in automatic unloading condition for 10 seconds, it will remain running unloaded for 30 - 10 = 20 seconds before stopping.
2920 1478 01
Instruction book
1.2.2 Shut-down warning If the regulator detects a temperature or pressure just below the programmed shut-down level, this will be indicated on the control panel to warn the operator before the shut-down level is reached. The message disappears as soon as the warning condition disappears. 1.2.3 Warning Depending on the compressor type, a warning message appears in case the dewpoint temperature exceeds the warning level (Full-Feature compressors).
1.6 Start commands during programmed stop time and minimum stop time
Pogrammed stop time After pressing stop button (1-Fig. 2.1), the compressor will run unloaded for a programmed time period. The compressor then stops. A start command during this period is ignored. Minimum stop time After stopping, the module prevents the motor from restarting within a programmed time period. A start command during this time will be memorized and executed after running out of this period.
2920 1478 01
Instruction book
Ref. 1 2 3 4 5 6 7 8 9 10 11 12 S2
Designation Stop button Start button Display Scroll keys Tabulator key Voltage on LED General alarm LED Automatic operation LED Function keys Pictograph Pictograph Pictograph Emergency stop button
Function Push button to stop the compressor. LED (8) goes out. Push button to start the compressor. LED (8) lights up indicating that the regulator is operative (in automatic operation). Indicates messages concerning the compressor operating condition, a service need or a fault. Keys to scroll through the display. Key to select the parameter indicated by a horizontal arrow. Indicates that the voltage is switched on. Is normally out. Is alight or blinks in case of an abnormal condition. See below. Indicates that the regulator is automatically controlling the compressor. Keys to control and program the compressor. See below. Alarm. Automatic operation. Voltage on. Push button to stop the compressor immediately in case of emergency. After remedying the trouble, unlock the button by pulling it out and press reset key 9.
2920 1478 01
Instruction book
3 Display - keys
3.1 Display (3-Fig. 2.1)
The display has four lines of 40 characters. A typical display is shown in Fig. 4.1. It indicates: 1. On the first three lines: the name of the sensor of which the actual reading is displayed the unit of measurement and actual reading of the sensor messages regarding the compressor operating condition (compressor off, etc.), a service need (e.g. for the oil filter and air filter) or a fault (e.g. shut-down) On the fourth line, just above the three function keys (F1/F2/F3), the actual functions of these keys.
2.
2920 1478 01
Instruction book
Function To modify programmable settings To program modified settings To reset a timer or message To return to a previously shown menu To unload the compressor manually
2920 1478 01
Instruction book
F2
Unload F3
Fig. 4.1 Main screen, typical example If the function keys or arrow keys are not used for some minutes, the display will automatically return to the Main screen. Whenever displayed on a submenu screen, press the key Mainscreen to return to the Main screen.
2920 1478 01
Instruction book
2920 1478 01
10
Instruction book
6.4 bar
Maximum Pressure 8.3 bar Running Hours Extra Loaded Hours Mainscreen Help 1016 hrs 980 hrs Extra
Unload
-Motor Starts -Module Hours -Load Relay -Compressor Outlet -Dp Oil Sseparator -Dp Air Filter -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium
-Oil Separator -Dryer LAT -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB 1 open/ PB2 closed -Overload Dryer/Dryer Fan
All Conditions Are OK -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Emergency Stop -Module Hours -Load Relay 1016 hrs 980 hrs 945 number Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Permisive Start Time -Communication Time-out Compressor Outlet 6.4 bar Dp Oil Separator Dp Air Filter Menu 0.4 bar - 0.02 bar -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB1 open/ PB2 closed -Overload Dryer/Dryer Fan -Remote Start/Stop -Remote LoadUnload -Remote Pressure Sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB1 open/ PB2 closed -Overload Dryer/Dryer Fan
Menu
Help
Compressor Outlet 6.4 bar -I Dp Oil Separator Dp Air Filter Menu 0.4 bar 0.02 bar
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 130 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Password -Node ID -Digital Presband Selec.
2920 1478 01
11
Instruction book
6.4 bar
Maximum Pressure 8.3 bar Running Hours Extra Loaded Hours Mainscreen Help 1016 hrs 980 hrs Extra
Unload
-Motor Starts -Module Hours -Load Relay -Compressor Outlet -Dp oilseparator -Dp Air Filter -Oil injection element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling medium -Oil separator -Dryer LAT
-Condensing Temperature -Dryer Ambient -Cool Water In -Cool Water Out -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote pressure sensing -Overload Motor -Starter Feedback Contact -PB 1 open/ PB2 closed -High Pressure Dryer -Overload Dryer
All Conditions Are OK -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Condensing Temperature -Dryer Ambient -Cool Water In -Cool Water Out -Emergency Stop -Remote Start/Stop -Remote LoadUnload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 open/ PB2 closed -High Pressure Dryer -Overload Dryer
Menu
Help
Compressor Outlet 6.4 bar -I Dp Oil Separator Dp Air Filter Menu 0.4 bar 0.02 bar
-Module Hours -Load Relay 1016 hrs 980 hrs 945 number Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Permisive Start Time -Communication Time-out Compressor Outlet 6.4 bar Dp Oil Separator Dp Air Filter Menu 0.4 bar - 0.02bar -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Condensing Temperature -Cool Water In -Cool Water Out -Dryer Ambient -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 open/ PB2 closed -High Pressure Dryer -Overload Dryer
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 130 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -Setpoint selection -CCM (control mode) -Automatic Restart -Password -Node ID -Digital Presband Selec.
2920 1478 01
12
Instruction book
Automatic Operation Local Control Week Timer Active Mainscreen Help Extra
Maximum Pressure bar Running Hours Loaded Hours Mainscreen Help 1016 hrs 980 hrs Extra
Unload
-Motor Starts -Module Hours -Load Relay -Compressor Outlet -Dp oilseparator -Dp Air Filter -Oil injection element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling medium
-Oil separator -Dryer LAT -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote pressure sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB 1 open/ PB2 closed -Overload dryerdryer fan
All Conditions Are OK -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Emergency Stop -Module Hours -Load Relay 1016 hrs 980 hrs 945 number Loading Pressure 18.0 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Permisive Start Time -Communication Time-out Compressor Outlet 19 bar Dp Oil Separator Dp Air Filter Menu 0.4 bar - 0.02 bar -Oil Injection Element -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Cooling Medium -Oil Separator -Dryer LAT -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB1 open/ PB2 closed -Overload Dryer/Dryer Fan -Remote Start/Stop -Remote LoadUnload -Remote Pressure Sensing -Overload Motor -Overload Fanmotor -Starter Feedback Contact -PB1 open/ PB2 closed -Overload Dryer/Dryer Fan
Menu
Help
Compressor Outlet 19 bar -I Dp Oil Separator Dp Air Filter Menu 0.4 bar 0.02 bar
Unloading Pressure 19.0 bar Loading Pressure 2 17.0 bar Menu Modify
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 130 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Password -Node ID -Digital Presband Selec.
2920 1478 01
13
Instruction book
2.5 bar
Maximum Pressure 3 bar Running Hours Extra Loaded Hours Mainscreen Help 1075 hrs
Unload
-Motor Starts -Module Hours -Load relay -Compressor Outlet -Dp Air Filter -Oil Pressure -Compressor Outlet -Element 1 Outlet -Cooling Water In -Cooling Water Out
-Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
All Conditions Are OK -Compressor Outlet -Element 1 Outlet -Cooling Water In -Cooling Water Out -Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
Menu
Help
Compressor Outlet 2.5 bar -I Dp Air Filter Oil Pressure Menu -0.026 bar 2.2 bar
-Module Hours -Load Relay 1075 hrs 980 hrs 945 number Loading Pressure 2.0 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Communication Time-out Compressor Outlet 2.5 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.2 bar -Compressor Outlet -Element 1 Outlet -Cooling Water In -Cooling Water Out -Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
Unloading Pressure 2.5 bar Loading Pressure 2 Menu Modify 1.8 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 175 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Node ID -MCC -Digital Presband Selection
2920 1478 01
14
Instruction book
6.4 bar
Maximum Pressure bar Running Hours Extra Loaded Hours Mainscreen Help 1075 hrs
Unload
-Motor Starts -Module Hours -Load Relay -Compressor Outlet -Dp Air Filter -Oil Pressure -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet
-Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
All Conditions Are OK -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
Menu
Help
Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.4 bar
-I
-Module Hours -Load Relay 1075 hrs 980 hrs 945 number Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Communication Time-out Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.4 bar -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 175 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Node ID -MCC -Digital Presband Selection
2920 1478 01
15
Instruction book
6.4 bar
bar
Unload
-Motor Starts -Module Hours -Load Relay -Compressor Outlet -Dp Air Filter -Oil Pressure -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet
-Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
All Conditions Are OK -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
Menu
Help
Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar bar
-I
-Module Hours -Load Relay 1075 hrs 980 hrs 945 number Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Communication Time-out Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar bar -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Overload Fan Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 175 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Node ID -MCC -Digital Presband Selection
2920 1478 01
16
Instruction book
6.4 bar
bar
Unload
-Motor Starts -Module Hours -Load relay -Compressor Outlet -Dp Air Filter -Oil Pressure -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet
-Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
All Conditions Are OK -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
Menu
Help
Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.5 bar
-I
1075 hrs 980 hrs Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Communication Time-out Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.5 bar -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Inlet -Element 2 Outlet -Oil Temperature -Emergency Stop -Remote Start/Stop -Remote Load/Unload -Remote Pressure Sensing -Overload Motor -Starter Feedback Contact -PB1 Open/PB2 Closed -Electr. Condensate Drain -Overload Dryer
945 number
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 175 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Pressure Band Used -Start Mode -CCM (control mode) -Automatic Restart -Node ID -MCC -Digital Presband Selection
2920 1478 01
17
Instruction book
6.4 bar
Maximum Pressure 7 bar Running Hours Extra Loaded Hours Mainscreen Help 1075 hrs
Unload
-Motor Starts -Module Hours -Compressor Outlet -Dp Air Filter -Oil Pressure -Intercooler -Compressor Outlet -Element 1 Outlet
-Element 2 Outlet -Element 2 Inlet -Cooling Water In -LP Cooling Water Out -Cooling Water Out -Oil Temperature -Emergency Stop -Remote Start/Stop
All Conditions Are OK -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Element 2 Inlet -Cooling Water In -LP Cooling Water Out -Cooling Water Out -Oil Temperature -Emergency Stop -Remote Start/Stop
Menu
Help
Compressor Outlet 6.4 bar -I Dp Air Filter Oil Pressure Menu -0.026 bar 2.5 bar -Module Hours -Load Relay 1075 hrs 980 hrs 945 number Loading Pressure 6.4 bar -I -Unloading Pressure 2 -Y-Time -Load Delay -Nr Of Starts/ Day -Minimum Stop Time -Programmed Stop Time -Communication Time-out Compressor Outlet 6.4 bar Dp Air Filter Oil Pressure Menu -0.026 bar 2.5 bar -Intercooler -Compressor Outlet -Element 1 Outlet -Element 2 Outlet -Element 2 Inlet -Cooling Water In -LP Cooling Water Out -Cooling Water Out -Oil Temperature -Emergency Stop -Remote StartStop
Unloading Pressure 7.0 bar Loading Pressure 2 Menu Modify 6.0 bar
Menu
Service Plan Clock Function Configuration Menu Modify Parameters Service Saved Data Mainscreen Menu Service Timer Running Hours 175 hrs Service Plan Clock Function Configuration Menu
Time Date
10:54 03/05/01
-Language In Use -Pressure Unit -Temperature Unit -Vibration Unit -Level Unit -Setpoint Selection -CCM (control mode) -Node ID
2920 1478 01
18
Instruction book
Help F2
Extra F3
Fig. 5.1 Example of an actual compressor status display Line 1 indicates the automatic or manual operation status of the regulator: <<Automatic operation>> means that the regulator automatically adapts the operation of the compressor, i.e. matching the compressor output to the air consumption. Line 2 indicates whether the regulator operates in local control or remote control mode: <<Local control>> means that the start/stop buttons on the keyboard are activated. <<Remote control>> means that these functions are controlled remotely. Consult Atlas Copco. Line 3 indicates whether the timer, which generates time-based start and stop commands, is activated or not. See section 13. See section 3.4 for the functions of keys Mainscreen, Help and Extra. 2. Press the key to get other data (actual compressor conditions of the compressor) as shown in Figs. 4.2 up to 4.9.
2920 1478 01
19
Instruction book
F3
Fig. 6.2 Example of a status data screen 1. 2. The indicators (***) are blinking. The screen shows the sensor (Element outlet), the actual reading (123 C), that the compressor is shut down (Shutdown), and the shutdown setting (110 C). It remains possible to scroll through other menus, e.g. to check the values of other parameters. When returning to the Status data menu, the option Shutdowns will blink. This option can be selected by pressing the tabulator key (5-Fig. 2.1) to return to the shutdown screen (Fig. 6.2).
2920 1478 01
20
Instruction book
Shut-down reset 1. 2. Switch off the voltage and remedy the trouble. After remedying and when the shut-down condition has disappeared, switch on the voltage and press the key Reset. Press the keys Menu and Mainscreen to return to the Main screen and restart the compressor by means of button I.
Reset of fan motor overload 1. 2. Switch off the voltage and remedy the trouble. Reset the overload relay after cooling off. When the shut-down condition has disappeared, switch on the voltage and press the key Reset. Press the keys Menu and Mainscreen to return to the Main screen and restart the compressor by means of button I.
Fig. 6.3 Example of a shut-down warning screen 2. 3. 4. The message *Shutdown Warning* appears. Press the key Menu (F1) and the tabulator key (5-Fig. 2.1) to select the Status data menu, the option Protection is blinking. Scroll to this option and select it by pressing the tabulator key (5-Fig. 2.1): option Warnings blinks, scroll to this option and select it by pressing the tabulator key. A screen similar to the one in Fig. 6.4 appears: 67 C 65 C *** F3
*** F2
Fig. 6.4 Example of a shut-down warning screen The screen shows that the temperature at the inlet of the HP compressor element (67 C) is too high. 5. If necessary, stop the compressor by means of button O and wait until the compressor has stopped. 6. Switch off the voltage, inspect the compressor and remedy. 7. The warning message will disappear automatically as soon as the warning condition disappears.
2920 1478 01
21
Instruction book
Fig. 6.5 Example of a warning screen 2. 3. 4. The indicators (***) are blinking and the service warning message appears. Press the key Menu (F1) and the tabulator key (5-Fig. 2.1) to select the Status data menu: the option Service is blinking. Scroll to this option and select it by pressing the tabulator key (5-Fig. 2.1), two options may blink: <<Inputs>>: if the programmed service level of a component is exceeded (e.g. the maximum pressure drop of the air filter). <<Plans>>: if a service plan interval is exceeded. Stop the compressor and switch off the voltage. In case the service message was referring to <<Inputs>> (air filter): replace the filter, switch on the voltage, scroll in the Status data menu to <<Inputs>> and press the Reset key to reset the service message. In case the service message was referring to <<Plans>>: carry out the service actions related to the indicated plans. Reset the timers of the related plans as described in section 15.
5. 6. 7.
2920 1478 01
22
Instruction book
8 Counters menu
Function To allow the operator to call up the: - running hours - loaded hours - number of motor starts - regulator (module) hours (the hours the module has been under tension) - load relay Procedure 1. Starting from the Main screen (see section 4.2): press the key Menu (F1) press the key until the option Counters is followed by a horizontal arrow press the tabulator key (5-Fig. 2.1) to activate the menu 2. By pressing the key, the above-mentioned items can be found (see also Figs. 4.2 up to 4.9). Loaded Hours Motor Starts Module hours Menu F1 98 hours 57 number 123 hours F2 F3
Fig. 8.1 Example of a counter screen The display indicates that: - the compressor has been in loaded condition for 98 hours - there have been 57 motor starts - the Elektronikon module has been under tension for 123 hours
2920 1478 01
23
Instruction book
9 Test menu
Function To carry out a display test, i.e. to check whether the display and LEDs are still intact. Procedure 1. Starting from the Main screen (see section 4.2): press the key Menu (F1) press the key until the option Test is followed by a horizontal arrow press the tabulator key (5-Fig. 2.1) to activate the menu 2. The option Display test will be followed by a horizontal arrow. 3. After pressing the tabulator key (5-Fig. 2.1), the regulator will generate a series of patterns on the display, which enable the operator to check, that each pixel still functions normally; at the same time the LEDs are lit.
10 Modify parameters
Function The menu allows the operator to program: Parameters Protections Service Plan Clock Function Configuration
2920 1478 01
24
Instruction book
Modifying the loading pressure setpoint If desired, the operator can program two pressure bands (Loading pressure/Unloading pressure and Loading pressure 2/Unloading pressure 2). 1. 2. 3. 4. 5. Consult the steps above to select <<Loading pressure>>. The screen shows that the current setting is 6.4 bar(e). To modify this setting, press the key Modify (F2); the setting will blink. The key Limits (F2) can be used to find out the limitations for the parameter. Use the or arrow key to change the value. Press the key Program (F1) to program the new setting or the key Cancel (F3) to cancel the modification operation. If required, the procedure to modify <<Unloading pressure>> is similar to the description above. 6.4 bar 7.0 bar 6.0 bar Modify F2 F3
2920 1478 01
25
Instruction book
Note Some parameters are not modifiable. Procedure 1. Starting from the Main screen (see section 4.2): press the key Menu (F1) press the key until the option Modify parameters is followed by a horizontal arrow press the tabulator key (5-Fig. 2.1) to activate the menu 2. Use the key to scroll until the option Protections is followed by a horizontal arrow. 3. Press the tabulator key (5-Fig. 2.1): the first item (e.g. Compressor outlet) and its value will appear. 4. Use the key to scroll until the parameter to be modified is followed by a horizontal arrow and press tabulator key (5-Fig. 2.1).
The screen shows that the current temperature is 94 C and that the shut-down setting is 110 C. To modify this setting, press the key Modify (F2): 94 C Maximum Limits F2 Modify parameters menu 110C (blinks) Cancel F3
2920 1478 01
26
Instruction book
3. 4. 5.
The key Limits (F2) can be used to find out the limitations for the parameter. Use the or arrow key to change the value. Press the key Program (F1) to program the new setting or the key Cancel (F3) to cancel the modification operation. The screen shown in Fig. 11.1 shows an arrow pointing to the right to call up the screen to modify the shut-down warning value: 94 C 100 C Modify F2 F3
The screen shows that the current temperature is 94 C and that the shut-down warning setting is 100 C. The modifying procedure is similar to the description above.
Note: The modifying procedure for other settings is similar. For some settings, a delay can be programmed. See section 17.
2920 1478 01
27
Instruction book
2.
Press the tabulator key (5-Fig. 2.1); following screen appears: Delete F3
F2
Use the or keys until the day on which a command must be programmed is followed by a right pointing arrow. Press the tabulator key (5-Fig. 2.1); following screen appears: ------------------------------------------------------------------------------------------Modify F2 -|
Delete F3
6. 7.
Press the key Modify (F2). The first two dashes will flash. Use the or key to enter <<06>>. Press the tabulator key to jump to the following two dashes. Use the or key to enter <<15>>. Press the tabulator key to jump to the row of dashes. Use the or key to enter the command Start Compressor. Press the key Program to program the command: 06:15 Start Compressor. Press the key: the symbol -| indicates that the second line is accessible. Press the key Modify and modify this line in a similar way to the following command line: 06:15 Pressure Band 1. Press the key Menu (F1) and scroll to <<Friday>>:
2920 1478 01
28
Instruction book
F2
Delete F3
Programming the command to change over to Pressure Band 2 at 18 oclock is carried out in a similar way as described above. Press the key Menu (F1) and scroll to <<Saturday>>. Programming the command to Compressor Stop at 18 oclock is carried out in a similar way as described above.
2.
Press the key Modify, <<Not activated>> starts blinking. Press the key, <<Not activated>> changes into <<Activated>>. Press the key Program.
Important: 1. It is necessary to program the start/stop/pressure band commands in successive order time wise, e.g.: 07.30 start 07.30 band 1 08.30 band 2 17.00 stop etc. 2. Make sure that the clock function is activated (indicated as <<Activated>>). If not, the programmed start/stop commands will not be executed.
2920 1478 01
29
Instruction book
2.
Use the key to scroll until the option Clock function is followed by a horizontal arrow. Press the tabulator key (5-Fig. 2.1); following screen appears: Modify F2 Delete F3
Press the tabulator key (5-Fig. 2.1); following screen appears: Modify F2 Delete F3
5. 6.
Scroll through the display until <<Saturday>> is followed by a horizontal arrow. Press the tabulator key (5-Fig. 2.1). If necessary, scroll through the compressor start/stop/pressure band commands until the command to be modified is followed by the horizontal arrow on the screen. Press the key Modify, the first two digits of the command start blinking. Modify as required using the scroll keys, i.e. in the example above change <<18>> into <<17>> using the key. If necessary, press the tabulator key (5-Fig. 2.1) to go to the next field to be modified, the minutes indication and the start/stop/pressure band indication. Press the key Program to program the new command or the key Cancel to quit without reprogramming.
Suppose the command to stop the compressor at 18:00 must be added to the list of Monday: - 06:15 start - 06:15 band 1
2920 1478 01
30
Instruction book
3.
Press the tabulator key (5-Fig. 2.1); following screen appears: Modify F2 Delete F3
4. 5. 6.
Scroll through the display until <<Monday>> is followed by a horizontal arrow. Press the tabulator key (5-Fig. 2.1). Scroll through the compressor start/stop/pressure band commands until the first empty command line is indicated by the horizontal arrow on the screen. Press the key Modify; the first two digits of the command start blinking. Enter <<18:00 stop>> using the scroll keys or to modify a field and the tabulator key (5-Fig. 2.1) to jump from one field to another. Press the key Program to program the new command or the key Cancel to quit without reprogramming.
Adding a command between two existing commands 1. Suppose the command 17:00 band 2 must be added to following list: - 06:00 start - 06:00 band 1 - 18:00 stop 2. The regulator does not allow to enter a new command which is situated before the last command in the list time wise. 3. Scroll through the display until the command before which the new command must be entered is followed by the horizontal arrow (in the example above: 18:00 stop) and press the key Modify. Change this command to the new command (in the example above: 17:00 band 2) and press the key Program. Press the key, add the last command of the list (in the example above: 18:00 stop) and press the key Program.
2.
Deleting all commands Press the key Delete (F3) in the screen above. A question to confirm the deleting operation will appear. Deleting all commands related to a specific day Scroll through the display until the desired day is followed by a horizontal arrow. Press the key Delete (F3). A question to confirm the deleting operation will appear.
2920 1478 01
31
Instruction book
Deleting a specific start/stop/pressure band command Scroll through the display until the command line to be deleted is followed by a horizontal arrow. Press the key Delete (F3). A question to confirm the deleting operation will appear.
2920 1478 01
32
Instruction book
14 Configuration menu
Function To reprogram a number of parameters. See Figs. 4.2 up to 4.9. Procedure 1. Starting from the Main screen (see section 4.2): press the key Menu (F1) press the key until the option Modify parameters is followed by a horizontal arrow press the tabulator key (5-Fig. 2.1) to activate the menu 2. Use the key to scroll until the option Configuration is followed by a horizontal arrow. 3. Press the tabulator key (5-Fig. 2.1): The first option shown is Time. If another option is desired, scroll through the display (using or keys) and select it using the tabulator key (5Fig. 2.1). 4. In case of option Time, the second line on the screen indicates the actual setting, e.g. 14:30. 5. If it is desired to modify the time, press key Modify. If not, press key Menu to return to the submenu. 6. After pressing the key Modify, the first field (14) will blink. Modify the hours using the or keys. Then press the tabulator key (5-Fig. 2.1) to go to the next field (i.e. 30). The setting of this field can now be modified with the or keys. 7. The bottom line of the display will show two options: Program to program the new setting Cancel to cancel the new setting 8. Proceed in a similar way for the other parameters to be modified.
<<Local control>> is blinking, use the or keys to select the desired control mode. Press the Program key to program or the Cancel key to cancel the modification.
2920 1478 01
33
Instruction book
15 Service menu
Function To reset the service plans which are carried out. To check for the next service plans to be carried out. To find out which service plans were carried out previously. Service plans Contact your Atlas Copco customer centre for the service actions related to these plans. Consult section 12 if any modification to the intervals should be required. When the service plan interval is reached, a message will appear on the screen. See section 6. Example Programmed service plan intervals ex-factory Service plans Service plan A Service plan B Service plan C Service plan D Resulting service actions to be carried out Service actions according to Service plan A Service plan A and B Service plan A Service plan A, B and C At 4000 running hours 8000 running hours 12000 running hours 16000 running hours . Intervals Every 4000 running hours Every 8000 running hours Every 16000 running hours Every 40000 running hours
Procedure 1. Starting from the Main screen (see section 4.2): press the key Menu (F1) press the key until the option Service is followed by a horizontal arrow press the tabulator key (5-Fig. 2.1) to activate the menu 2. A screen similar to the one below appears: Service Timer Running Hours 7971 hrs Menu F1 Fig. 15.1 F2 Service menu F3
The screen shows that the total compressor running time is 7971 hrs.
2920 1478 01
34
Instruction book
3.
F2 Service menu
The screen shows that the next service plans to be carried out are plans A and B and that these plans are to be carried out every 8000 running hours. 4. Press the key to find out which service plans were carried out previously:
A 4008 hrs F3
The screen shows that service plan A was carried out at 4008 running hours. 5. 6. Stop the compressor, switch off the voltage and carry out the service operations related to plans A and B. Switch on the voltage and scroll to the service screen shown in Fig. 15.2. Press the Reset button (F3) to reset the timer. Confirm the question for resetting.
Notes The Reset button only appears when the Next Timer level is almost reached before elapsing of the service plan interval. After pressing the key in Fig. 15.1, the Life time hours are shown (i.e. the number of hours elapsed since initial programming ex-factory). This counter is not taken into account.
2920 1478 01
35
Instruction book
17 Programmable settings
17.1 GA90 (W) up to GA315 (W)
Remark: Consult the notes at the end of this chapter. 17.1.1 Parameters Minimum 10 0 10 0 0 20 30 0 15 0 10 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 Nominal 10 0 10 72 3 20 30 30 15 3 20 7.0 8.0 9.5 12.5 6.9 8.6 10.3 13.3 6.75 7.75 9.25 12.25 6.65 8.35 10.05 13.05 6.4 7.4 8.9 11.9 6.3 8.0 9.7 12.7 Maximum 20 20 20 72 3 99 30 255 3600 255 60 7.505 8.505 10.005 13.005 7.405 9.105 10.805 13.805 7.255 8.255 9.755 12.755 7.155 8.855 10.555 13.650 6.905 7.905 9.405 12.405 6.805 8.505 10.205 13.305
Motor running time in star Load delay time (star-delta) Load delay time (no star-delta) Number of motor starts (star-delta) Number of motor starts (no star-delta) Minimum stop time Programmed stop time Permissive start time Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 7.5 bar Pack compressors - 8.5 bar Pack compressors - 10 bar Pack compressors - 13 bar Pack compressors - 100 psi Pack compressors - 125 psi Pack compressors - 150 psi Pack compressors - 200 psi Pack compressors - 7.5 bar Full-Feature compressors - 8.5 bar Full-Feature compressors - 10 bar Full-Feature compressors - 13 bar Full-Feature compressors - 100 psi Full-Feature compressors - 125 psi Full-Feature compressors - 150 psi Full-Feature compressors - 200 psi Full-Feature compressors - 7.5 bar Full-Feature compressors with DD filter - 8.5 bar Full-Feature compressors with DD filter - 10 bar Full-Feature compressors with DD filter - 13 bar Full-Feature compressors with DD filter - 100 psi Full-Feature compressors with DD filter - 125 psi Full-Feature compressors with DD filter - 150 psi Full-Feature compressors with DD filter - 200 psi Full-Feature compressors with DD filter
sec sec sec starts/day starts/day sec sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
36
Instruction book
Minimum Loading pressure - 7.5 bar Pack compressors - 8.5 bar Pack compressors - 10 bar Pack compressors - 13 bar Pack compressors - 100 psi Pack compressors - 125 psi Pack compressors - 150 psi Pack compressors - 200 psi Pack compressors - 7.5 bar Full-Feature compressors - 8.5 bar Full-Feature compressors - 10 bar Full-Feature compressors - 13 bar Full-Feature compressors - 100 psi Full-Feature compressors - 125 psi Full-Feature compressors - 150 psi Full-Feature compressors - 200 psi Full-Feature compressors - 7.5 bar Full-Feature compressors with DD filter - 8.5 bar Full-Feature compressors with DD filter - 10 bar Full-Feature compressors with DD filter - 13 bar Full-Feature compressors with DD filter - 100 psi Full-Feature compressors with DD filter - 125 psi Full-Feature compressors with DD filter - 150 psi Full-Feature compressors with DD filter - 200 psi Full-Feature compressors with DD filter bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5
Nominal 6.4 7.4 8.9 11.9 6.3 8.0 9.7 12.7 6.15 7.15 8.65 11.65 6.05 7.75 9.45 12.45 5.8 6.8 8.3 11.3 5.7 7.4 9.1 12.1
Maximum 7.505 8.505 10.005 13.005 7.405 9.105 10.805 13.805 7.255 8.255 9.755 12.755 7.155 8.855 10.555 13.650 6.905 7.905 9.405 12.405 6.805 8.505 10.205 13.305
2920 1478 01
37
Instruction book
17.1.2 Protections Minimum 0 0 2.0 0 0 0 0 5 80 80 80 80 5 0 0 0 0 0 0 0 0 5 0 3 3 0 0 Nominal 16.5 17.0 2.5 66 80 66 80 5 100 110 114 120 5 120 1 1 1 1 13 2 15 5 1 15 16 3 255 Maximum 17.0 17.0 13.2 120 120 100 100 5 110 110 120 120 5 120 3 3 3 3 60 3 60 5 3 50 50 10 255
Compressor outlet pressure (shut-down warning level) Compressor outlet pressure (shut-down level) Oil injection pressure, element (start protection) Compressor outlet temperature (without DD filter) (shut-down warning level) Compressor outlet temperature (without DD filter) (shut-down level) Compressor outlet temperature (with DD filter) (shut-down warning level) Compressor outlet temperature (with DD filter) (shut-down level) Compressor outlet temperature (delay at signal) Compressor element outlet temperature (no energy recovery) (shut-down warning level) Compressor element outlet temperature (no energy recovery) (shut-down level) Compressor element outlet temperature (energy recovery) (shut-down warning level) Compressor element outlet temperature (energy recovery) (shut-down level) Compressor element outlet temperature (delay at signal) Oil separator temperature Delay at start, overload motor Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, starter feedback contact = open Delay at signal, starter feedback contact = closed Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, overload dryer/dryer fan For Full-Feature also: Dryer LAT temperature (warning) Dryer LAT temperature (shut-down) Delay at signal Delay at starting
bar(e) bar(e) bar(e) C C C C sec C C C C sec C sec sec sec sec sec sec sec sec sec C C sec sec
2920 1478 01
38
Instruction book
17.1.3 Service settings Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp oil separator Delay at signal, Dp oil separator Dp air filter Delay at signal, Dp air filter Dp DD filter Delay at signal, Dp DD filter hr hr hr hr hr mbar sec mbar sec mbar sec 0 0 -100 0 100 0 Nominal 4000 8000 16000 24000 2000 800 60 -50 60 350 60 800 255 -50 255 350 255 Maximum
2920 1478 01
39
Instruction book
Motor running time in star Load delay time (star-delta) Load delay time (no star-delta) Number of motor starts (star-delta) Number of motor starts (no star-delta) Minimum stop time Programmed stop time Permissive start time Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 13 bar Pack compressors - 20 bar Pack compressors - 200 psi Pack compressors - 13 bar Full-Feature compressors - 20 bar Full-Feature compressors - 200 psi Full-Feature compressors - 13 bar Full-Feature compressors with DD filter - 200 psi Full-Feature compressors with DD filter Loading pressure - 13 bar Pack compressors - 20 bar Pack compressors - 200 psi Pack compressors - 13 bar Full-Feature compressors - 20 bar Full-Feature compressors - 200 psi Full-Feature compressors - 13 bar Full-Feature compressors with DD filter - 200 psi Full-Feature compressors with DD filter
sec sec sec starts/day starts/day sec sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
40
Instruction book
17.2.2 Protections Minimum 0 0 0 0 2.0 0 0 0 0 5 80 80 80 80 5 0 0 0 0 0 0 0 0 5 0 3 3 0 0 Nominal 16.5 17.0 24.5 25.0 2.5 66 80 66 80 5 114 120 114 120 5 120 1 1 1 1 13 2 15 5 1 15 16 3 255 Maximum 17.0 17.0 25.0 25.0 13.2 120 120 100 100 5 120 120 120 120 5 120 3 3 3 3 60 3 60 5 3 50 50 10 255
Compressor outlet pressure 13 bar or 200 psi compressors (shut-down warning level) Compressor outlet pressure 13 bar or 200 psi compressors (shut-down level) Compressor outlet pressure 20 bar compressors (shut-down warning level) Compressor outlet pressure 20 bar compressors (shut-down level) Oil injection pressure, element (start protection) Compressor outlet temperature (without DD filter) (shut-down warning level) Compressor outlet temperature (without DD filter) (shut-down level) Compressor outlet temperature (with DD filter) (shut-down warning level) Compressor outlet temperature (with DD filter) (shut-down level) Compressor outlet temperature (delay at signal) Compressor element 1 outlet temperature (shut-down warning level) Compressor element 1 outlet temperature (shut-down level) Compressor element 2 outlet temperature (shut-down warning level) Compressor element 2 outlet temperature (shut-down level) Compressor element outlet temperature (delay at signal) Oil separator temperature Delay at start, overload motor Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, starter feedback contact = open Delay at signal, starter feedback contact = closed Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, overload dryer/dryer fan For Full-Feature also: Dryer LAT temperature (warning) Dryer LAT temperature (shut-down) Delay at signal Delay at starting
bar(e) bar(e) bar(e) bar(e) bar(e) C C C C sec C C C C sec C sec sec sec sec sec sec sec sec sec C C sec sec
2920 1478 01
41
Instruction book
17.2.3 Service settings Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp oil separator Delay at signal, Dp oil separator Dp air filter Delay at signal, Dp air filter Dp DD filter Delay at signal, Dp DD filter hr hr hr hr hr mbar sec mbar sec mbar sec 0 0 -100 0 100 0 Nominal 4000 8000 16000 24000 2000 800 60 -50 60 350 60 800 255 -50 255 350 255 Maximum
2920 1478 01
42
Instruction book
Motor running time in star Load delay time (star-delta) Load delay time (no star-delta) Number of motor starts (star-delta) Number of motor starts (no star-delta) Minimum stop time Programmed stop time (without full-load/no-load valve) Programmed stop time (with full-load/no-load valve) Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 1 bar ZE/ZA compressors without aftercooler - 1.25 bar ZE/ZA compressors without aftercooler - 1.5 bar ZE/ZA compressors without aftercooler - 1.75 bar ZE/ZA compressors without aftercooler - 2 bar ZE/ZA compressors without aftercooler - 2.25 bar ZE/ZA compressors without aftercooler - 2.5 bar ZE/ZA compressors without aftercooler - 2.75 bar ZE/ZA compressors without aftercooler - 3 bar ZE/ZA compressors without aftercooler - 3.25 bar ZE/ZA compressors without aftercooler - 3.5 bar ZE/ZA compressors without aftercooler - 1 bar ZE compressors with aftercooler - 1.25 bar ZE compressors with aftercooler - 1.5 bar ZE compressors with aftercooler - 1.75 bar ZE compressors with aftercooler - 2 bar ZE compressors with aftercooler - 2.25 bar ZE compressors with aftercooler - 2.5 bar ZE compressors with aftercooler - 2.75 bar ZE compressors with aftercooler - 3 bar ZE compressors with aftercooler - 3.25 bar ZE compressors with aftercooler - 3.5 bar ZE compressors with aftercooler
sec sec sec starts/day starts/day sec sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
43
Instruction book
Unloading pressure - 1 bar ZE4 high speed compressors with aftercooler - 1.25 bar ZE4 high speed compressors with aftercooler - 1.5 bar ZE4 high speed compressors with aftercooler - 1.75 bar ZE4 high speed compressors with aftercooler - 2 bar ZE4 high speed compressors with aftercooler - 2.25 bar ZE4 high speed compressors with aftercooler - 2.5 bar ZE4 high speed compressors with aftercooler - 2.75 bar ZE4 high speed compressors with aftercooler - 3 bar ZE4 high speed compressors with aftercooler - 3.25 bar ZE4 high speed compressors with aftercooler - 3.5 bar ZE4 high speed compressors with aftercooler
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
0.45 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Minimum
0.75 1.00 1.25 1.5 1.8 2.1 2.35 2.6 2.85 3.15 3.3 Nominal 0.7 0.95 1.2 1.45 1.7 1.95 2.2 2.45 2.7 2.95 3.2 0.6 0.85 1.13 1.38 1.7 1.9 2.15 2.4 2.65 2.9 3.05 0.45 0.7 0.95 1.2 1.5 1.8 2.05 2.3 2.55 2.85 3.0
1.0 1.25 1.5 1.75 2.05 2.35 2.6 2.85 3.1 3.4 3.55 Maximum 1.25 1.5 1.75 2.0 2.25 2.5 2.75 3.0 3.25 3.5 3.6 1.15 1.4 1.68 1.93 2.18 2.45 2.7 2.95 3.2 3.45 3.6 1.0 1.25 1.5 1.75 2.05 2.35 2.6 2.85 3.1 3.4 3.55
Loading pressure - 1 bar ZE/ZA compressors without aftercooler - 1.25 bar ZE/ZA compressors without aftercooler - 1.5 bar ZE/ZA compressors without aftercooler - 1.75 bar ZE/ZA compressors without aftercooler - 2 bar ZE/ZA compressors without aftercooler - 2.25 bar ZE/ZA compressors without aftercooler - 2.5 bar ZE/ZA compressors without aftercooler - 2.75 bar ZE/ZA compressors without aftercooler - 3 bar ZE/ZA compressors without aftercooler - 3.25 bar ZE/ZA compressors without aftercooler - 3.5 bar ZE/ZA compressors without aftercooler - 1 bar ZE compressors with aftercooler - 1.25 bar ZE compressors with aftercooler - 1.5 bar ZE compressors with aftercooler - 1.75 bar ZE compressors with aftercooler - 2 bar ZE compressors with aftercooler - 2.25 bar ZE compressors with aftercooler - 2.5 bar ZE compressors with aftercooler - 2.75 bar ZE compressors with aftercooler - 3 bar ZE compressors with aftercooler - 3.25 bar ZE compressors with aftercooler - 3.5 bar ZE compressors with aftercooler - 1 bar ZE4 high speed compressors with aftercooler - 1.25 bar ZE4 high speed compressors with aftercooler - 1.5 bar ZE4 high speed compressors with aftercooler - 1.75 bar ZE4 high speed compressors with aftercooler - 2 bar ZE4 high speed compressors with aftercooler - 2.25 bar ZE4 high speed compressors with aftercooler - 2.5 bar ZE4 high speed compressors with aftercooler - 2.75 bar ZE4 high speed compressors with aftercooler - 3 bar ZE4 high speed compressors with aftercooler - 3.25 bar ZE4 high speed compressors with aftercooler - 3.5 bar ZE4 high speed compressors with aftercooler
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.45 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
2920 1478 01
44
Instruction book
17.3.2 Protections
Compressor outlet pressure (compressors without load/no-load valve) (shut-down warning level) Compressor outlet pressure (compressors without load/no-load valve) (shut-down level) Compressor outlet pressure (compressors with load/no-load valve) (shut-down warning level) Compressor outlet pressure (compressors with load/no-load valve (shut-down level) Oil pressure (shut-down warning level) Oil pressure (shut-down level) Delay at start, oil pressure Delay at signal, oil pressure Element 1 outlet temperature, ZE 1 up to 2.75 bar (shut-down warning level) Element 1 outlet temperature, ZE 1 up to 2.75 bar (shut-down level) Element 1 outlet temperature, ZE 3 up to 3.5 bar (shut-down warning level) Element 1 outlet temperature, ZE 3 up to 3.5 bar (shut-down level) Element 1 outlet temperature, ZA 1 up to 2.75 bar (shut-down warning level) Element 1 outlet temperature, ZA 1 up to 2.75 bar (shut-down level) Element 1 outlet temperature, ZA 3 up to 3.5 bar (shut-down warning level) Element 1 outlet temperature, ZA 3 up to 3.5 bar (shut-down level) Delay at signal, element 1 outlet temperature Oil temperature (shut-down warning level) Oil temperature (shut-down level) Delay at start, oil temperature Delay at signal, oil temperature Delay at start, overload motor Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, starter feedback contact = open Delay at signal, starter feedback contact = closed Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, overload dryer/dryer fan Delay at signal, phase sequence
fullfullfullfull-
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) sec sec C C C C C C C C sec C C sec sec sec sec sec sec sec sec sec sec sec sec
Minimum 0 0 0 0 1.0 1.0 15 0 100 100 100 100 100 100 100 100 0 40 40 50 0 0 0 0 0 0 0 0 5 0 0
Nominal Consult Atlas Copco Consult Atlas Copco 4.5 5.0 1.5 1.4 20 1 230 240 255 265 225 235 250 260 1 66 70 70 1 1 1 1 1 23 2 15 5 1 1
Maximum Consult Atlas Copco Consult Atlas Copco 5.0 5.0 2.0 2.0 30 3 240 240 265 265 235 235 260 260 3 80 80 100 3 3 3 3 3 40 3 60 5 3 2
2920 1478 01
45
Instruction book
17.3.3 Service settings Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp air filter Delay at signal, Dp air filter hr hr hr hr hr mbar sec -55 0 Nominal 4000 8000 16000 40000 2000 -44 60 -44 255 Maximum
2920 1478 01
46
Instruction book
17.4 ZA 5-6
Remark: Consult the notes at the end of this chapter. 17.4.1 Parameters Minimum 10 5 20 0 0 20 0 0 15 0 10 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Nominal 10 5 20 72 3 20 0 3 15 3 20 1.0 1.25 1.5 1.75 2.0 2.25 2.5 2.75 3.0 3.25 3.5 0.94 1.19 1.49 1.69 1.94 0.99 1.24 1.49 1.74 1.99 2.19 2.44 2.69 2.94 3.19 3.44 Maximum 20 30 30 120 5 99 20 20 3600 255 60 1.25 1.5 1.75 2.0 2.25 2.5 2.75 3.0 3.25 3.5 3.6 1.19 1.44 1.69 1.94 2.19 1.24 1.49 1.74 1.99 2.24 2.44 2.69 2.94 3.19 3.44 3.59
Motor running time in star Load delay time (star-delta) Load delay time (no star-delta) Number of motor starts (star-delta) Number of motor starts (no star-delta) Minimum stop time Programmed stop time (without full-load/no-load valve) Programmed stop time (with full-load/no-load valve) Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 1 bar ZA compressors without aftercooler - 1.25 bar ZA compressors without aftercooler - 1.5 bar ZA compressors without aftercooler - 1.75 bar ZA compressors without aftercooler - 2 bar ZA compressors without aftercooler - 2.25 bar ZA compressors without aftercooler - 2.5 bar ZA compressors without aftercooler - 2.75 bar ZA compressors without aftercooler - 3 bar ZA compressors without aftercooler - 3.25 bar ZA compressors without aftercooler - 3.5 bar ZA compressors without aftercooler - 1 bar ZA5 compressors with aftercooler - 1.25 bar ZA5 compressors with aftercooler - 1.5 bar ZA5 compressors with aftercooler - 1.75 bar ZA5 compressors with aftercooler - 2 bar ZA5 compressors with aftercooler - 1 bar ZA6 compressors with aftercooler - 1.25 bar ZA6 compressors with aftercooler - 1.5 bar ZA6 compressors with aftercooler - 1.75 bar ZA6 compressors with aftercooler - 2 bar ZA6 compressors with aftercooler - 2.25 bar ZA5-6 compressors with aftercooler - 2.5 bar ZA5-6 compressors with aftercooler - 2.75 bar ZA5-6 compressors with aftercooler - 3 bar ZA5-6 compressors with aftercooler - 3.25 bar ZA5-6 compressors with aftercooler - 3.5 bar ZA5-6 compressors with aftercooler
sec sec sec starts/day starts/day sec sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
47
Instruction book
Unloading pressure - 1 bar ZA5 high speed compressors with aftercooler - 1.25 bar ZA5 high speed compressors with aftercooler - 1.5 bar ZA5 high speed compressors with aftercooler - 1.75 bar ZA5 high speed compressors with aftercooler - 2 bar ZA5 high speed compressors with aftercooler - 1 bar ZA6 high speed compressors with aftercooler - 1.25 bar ZA6 high speed compressors with aftercooler - 1.5 bar ZA6 high speed compressors with aftercooler - 1.75 bar ZA6 high speed compressors with aftercooler - 2 bar ZA6 high speed compressors with aftercooler - 2.25 bar ZA6 high speed compressors with aftercooler - 2.5 bar ZA6 high speed compressors with aftercooler - 2.75 bar ZA6 high speed compressors with aftercooler - 3 bar ZA6 high speed compressors with aftercooler - 3.25 bar ZA6 high speed compressors with aftercooler - 3.5 bar ZA6 high speed compressors with aftercooler Loading pressure - 1 bar ZA compressors without aftercooler - 1.25 bar ZA compressors without aftercooler - 1.5 bar ZA compressors without aftercooler - 1.75 bar ZA compressors without aftercooler - 2 bar ZA compressors without aftercooler - 2.25 bar ZA compressors without aftercooler - 2.5 bar ZA compressors without aftercooler - 2.75 bar ZA compressors without aftercooler - 3 bar ZA compressors without aftercooler - 3.25 bar ZA compressors without aftercooler - 3.5 bar ZA compressors without aftercooler - 1 bar ZA5 compressors with aftercooler - 1.25 bar ZA5 compressors with aftercooler - 1.5 bar ZA5 compressors with aftercooler - 1.75 bar ZA5 compressors with aftercooler - 2 bar ZA5 compressors with aftercooler - 1 bar ZA6 compressors with aftercooler - 1.25 bar ZA6 compressors with aftercooler - 1.5 bar ZA6 compressors with aftercooler - 1.75 bar ZA6 compressors with aftercooler - 2 bar ZA6 compressors with aftercooler - 2.25 bar ZA5-6 compressors with aftercooler - 2.5 bar ZA5-6 compressors with aftercooler - 2.75 bar ZA5-6 compressors with aftercooler - 3 bar ZA5-6 compressors with aftercooler - 3.25 bar ZA5-6 compressors with aftercooler - 3.5 bar ZA5-6 compressors with aftercooler - 1 bar ZA5 high speed compressors with aftercooler - 1.25 bar ZA5 high speed compressors with aftercooler - 1.5 bar ZA5 high speed compressors with aftercooler - 1.75 bar ZA5 high speed compressors with aftercooler - 2 bar ZA5 high speed compressors with aftercooler
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nominal 0.9 1.15 1.4 1.65 1.9 0.98 1.23 1.48 1.73 1.98 2.15 2.4 2.65 2.9 3.15 3.4 Nominal 0.7 0.95 1.2 1.45 1.7 1.95 2.2 2.45 2.7 2.95 3.2 0.64 0.89 1.14 1.39 1.64 0.69 0.94 1.19 1.44 1.69 1.89 2.14 2.39 2.64 2.89 3.14 0.6 0.85 1.1 1.35 1.6
Maximum 1.15 1.4 1.65 1.9 2.15 1.23 1.48 1.73 1.98 2.23 2.4 2.65 2.9 3.15 3.4 3.5 Maximum 1.25 1.5 1.75 2.0 2.25 2.5 2.75 3.0 3.25 3.5 3.6 1.19 1.44 1.69 1.94 2.19 1.24 1.49 1.74 1.99 2.24 2.44 2.69 2.94 3.19 3.44 3.59 1.15 1.4 1.65 1.9 2.15
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
48
Instruction book
Loading pressure - 1 bar ZA6 high speed compressors with aftercooler - 1.25 bar ZA6 high speed compressors with aftercooler - 1.5 bar ZA6 high speed compressors with aftercooler - 1.75 bar ZA6 high speed compressors with aftercooler - 2 bar ZA6 high speed compressors with aftercooler - 2.25 bar ZA6 high speed compressors with aftercooler - 2.5 bar ZA6 high speed compressors with aftercooler - 2.75 bar ZA6 high speed compressors with aftercooler - 3 bar ZA6 high speed compressors with aftercooler - 3.25 bar ZA6 high speed compressors with aftercooler - 3.5 bar ZA6 high speed compressors with aftercooler bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
Minimum 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Nominal 0.68 0.93 1.18 1.43 1.68 1.85 2.1 2.35 2.6 2.85 3.1
Maximum 1.23 1.48 1.73 1.98 2.23 2.4 2.65 2.9 3.15 3.4 3.5
2920 1478 01
49
Instruction book
17.4.2 Protections Minimum 0 0 0 0 1.0 1.0 15 0 100 100 100 100 0 40 40 50 0 0 0 0 0 0 0 0 5 0 0 Nominal Consult Atlas Copco Consult Atlas Copco 4.5 5.0 1.5 1.4 20 1 225 235 250 260 1 66 70 70 1 1 1 1 1 23 2 15 5 1 1 Maximum Consult Atlas Copco Consult Atlas Copco 5.0 5.0 2.0 2.0 30 3 235 235 260 260 3 80 80 100 3 3 3 3 3 40 3 60 5 3 2
Compressor outlet pressure (compressors without load/no-load valve) (shut-down warning level) Compressor outlet pressure (compressors without load/no-load valve) (shut-down level) Compressor outlet pressure (compressors with load/no-load valve) (shut-down warning level) Compressor outlet pressure (compressors with load/no-load valve (shut-down level) Oil pressure (shut-down warning level) Oil pressure (shut-down level) Delay at start, oil pressure Delay at signal, oil pressure Element 1 outlet temperature 1 up to 2.75 bar (shut-down warning level) Element 1 outlet temperature 1 up to 2.75 bar (shut-down level) Element 1 outlet temperature 3 up to 3.5 bar (shut-down warning level) Element 1 outlet temperature 3 up to 3.5 bar (shut-down level) Delay at signal, element 1 outlet temperature Oil temperature (shut-down warning level) Oil temperature (shut-down level) Delay at start, oil temperature Delay at signal, oil temperature Delay at start, overload motor Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, starter feedback contact = open Delay at signal, starter feedback contact = closed Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, overload dryer/dryer fan Delay at signal, phase sequence
fullfullfullfull-
bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) sec sec C C C C sec C C sec sec sec sec sec sec sec sec sec sec sec sec
2920 1478 01
50
Instruction book
17.4.3 Service settings Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp air filter Delay at signal, Dp air filter hr hr hr hr hr mbar sec -55 0 Nominal 4000 8000 16000 40000 2000 -44 60 -44 255 Maximum
2920 1478 01
51
Instruction book
Motor running time in star Load delay time Number of motor starts Minimum stop time Programmed stop time Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 7.5 bar compressors Pack - 8.6 bar compressors Pack - 7.5 bar compressors Full-Feature - 8.6 bar compressors Full-Feature Loading pressure - 7.5 bar compressors Pack - 8.6 bar compressors Pack - 7.5 bar compressors Full-Feature - 8.6 bar compressors Full-Feature
sec sec starts/day sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
17.5.2 Protections Minimum 1.0 1.0 15 0 100 100 60 60 0 0 100 100 -0.68 0 Nominal 2.0 1.9 15 6 220 225 85 90 0 0 220 225 -0.68 0 Maximum 2.0 2.0 20 9 225 225 90 90 255 255 225 225 -0.68 0
Oil pressure (shut-down warning level) Oil pressure (shut-down level) Delay at start, oil pressure Delay at signal, oil pressure Element 1 outlet temperature (shut-down warning level) Element 1 outlet temperature (shut-down level) Element 2 inlet temperature (shut-down warning level) Element 2 inlet temperature (shut-down level) Delay at start, element 2 inlet temperature Delay at signal, element 2 inlet temperature Element 2 outlet temperature (shut-down warning level) Element 2 outlet temperature (shut-down level) Intercooler pressure (warning level) Delay at start, overload motor
2920 1478 01
52
Instruction book
Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, phase sequence
1 0 1 0 0 0
1 0 1 0 0 1
1 0 1 255 255 2
Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp air filter Delay at start, Dp air filter Delay at signal, Dp air filter hr hr hr hr hr mbar sec sec -100 0 0
Maximum
-44 0 255
2920 1478 01
53
Instruction book
Motor running time in star Load delay time (star-delta) Number of motor starts (star-delta) Minimum stop time Programmed stop time Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 7.25 bar compressors - 7.5 bar compressors - 8.6 bar compressors - 9 bar compressors - 10 bar compressors - 10.4 bar compressors Loading pressure - 7.25 bar compressors - 7.5 bar compressors - 8.6 bar compressors - 9 bar compressors - 10 bar compressors - 10.4 bar compressors
sec sec starts/day sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
54
Instruction book
17.6.2 Protections Minimum 1.0 1.0 15 0 100 100 100 100 40 40 100 100 100 100 40 40 53 100 90 Nominal 1.3 1.2 15 6 210 220 225 235 65 70 210 220 225 235 65 70 53 110 100 Maximum 1.9 1.9 20 9 220 220 235 235 80 80 220 220 235 235 80 80 58 110 100
Oil pressure (shut-down warning level) Oil pressure (shut-down level) Delay at start, oil pressure Delay at signal, oil pressure Element 1 outlet temperature 7.25 and 7.5 bar (shut-down warning level) Element 1 outlet temperature 7.25 and 7.5 bar (shut-down level) Element 1 outlet temperature 8.6, 9, 10 and 10.4 bar (shut-down warning level) Element 1 outlet temperature 8.6, 9, 10 and 10.4 bar (shut-down level) Element 2 inlet temperature (shut-down warning level) Element 2 inlet temperature (shut-down level) Element 2 outlet temperature 7.25 and 7.5 bar (shut-down warning level) Element 2 outlet temperature 7.25 and 7.5 bar (shut-down level) Element 2 outlet temperature 8.6, 9, 10 and 10.4 bar (shut-down warning level) Element 2 outlet temperature 8.6, 9, 10 and 10.4 bar (shut-down level) Oil temperature (ZR) (shut-down warning level) Oil temperature (ZR) (shut-down level) Temperature inlet dryer (for Full-Feature) (warning level) Temperature, regeneration air inlet dryer (for FullFeature) (warning level) Calculated temperature, Delta T element (for FullFeature) (warning level)
2920 1478 01
55
Instruction book
Minimum Service plans Service plan A (50 Hz) (running hours) Service plan A (60 Hz) (running hours) Service plan B (running hours) Service plan C (running hours) Service plan I (running hours) Analog signals Dp air filter Delay at signal, Dp air filter hr hr hr hr hr mbar sec -100 0
Maximum
-44 255
2920 1478 01
56
Instruction book
Motor running time in star Load delay time (star-delta) Load delay time (no star-delta) Number of motor starts (star-delta) Number of motor starts (no star-delta) Minimum stop time Programmed stop time Power recovery time (ARAVF) Restart delay (ARAVF) Communication time-out Unloading pressure - 7.5 bar compressors - 8.6 bar compressors - 10 bar compressors - 10.4 bar compressors Loading pressure - 7.5 bar compressors - 8.6 bar compressors - 10 bar compressors - 10.4 bar compressors
sec sec sec starts/day starts/day sec sec sec sec sec bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e) bar(e)
2920 1478 01
57
Instruction book
17.7.2 Protections
Compressor outlet pressure (shut-down warning level) Compressor outlet pressure (shut-down level) Compressor outlet pressure (delay at start) Compressor outlet pressure (delay at signal) Oil pressure ZT/ZR110-275 (shut-down warning level) Oil pressure ZT/ZR110-275 (shut-down level) Oil pressure ZR300-750 (shut-down warning level) Oil pressure ZR300-750 (shut-down level) Delay at start, oil pressure Delay at signal, oil pressure Element 1 outlet temperature 7.5 and 8.6 bar (shut-down warning level) Element 1 outlet temperature 7.5 and 8.6 bar (shut-down level) Element 1 outlet temperature 10 and 10.4 bar (shut-down warning level) Element 1 outlet temperature 10 and 10.4 bar (shut-down level) Element 2 inlet temperature (shut-down warning level) Element 2 inlet temperature (shut-down level) Element 2 outlet temperature 7.5 and 8.6 bar (shut-down warning level) Element 2 outlet temperature 7.5 and 8.6 bar (shut-down level) Element 2 outlet temperature 10 and 10.4 bar (shut-down warning level) Element 2 outlet temperature 10 and 10.4 bar (shut-down level) Delay at signal of all element temperatures Oil temperature (shut-down warning level) Oil temperature (shut-down level) Delay at signal, oil temperature Delay at start, overload motor Delay at signal, overload motor Delay at start, overload fan motor Delay at signal, overload fan motor Delay at start, starter feedback contact = open Delay at signal, starter feedback contact = closed Delay at start, electric condensate drain Delay at signal, electric condensate drain Delay at signal, phase sequence
bar(e) bar(e) sec sec bar(e) bar(e) bar(e) bar(e) sec sec C C C C C C C C C C sec C C sec sec sec sec sec sec sec sec sec sec
Minimum 0 0 0 0 1.0 1.0 1.0 1.0 15 0 100 100 100 100 40 40 100 100 100 100 0 40 40 50 0 0 0 0 0 0 0 5 0
Nominal 14.0 15.0 1 1 1.3 1.2 1.3 1.2 15 1 210 220 225 235 65 70 210 220 225 235 1 65 70 70 1 1 1 1 18 2 15 5 1
Maximum 17.0 17.0 3 3 2.0 2.0 1.9 1.9 20 3 220 220 235 235 80 80 220 220 235 235 3 80 80 100 3 3 3 3 33 3 60 5 2
2920 1478 01
58
Instruction book
17.7.3 Service settings Minimum Service plans Service plan A (running hours) Service plan B (running hours) Service plan C (running hours) Service plan D (running hours) Service plan I (running hours) Analog signals Dp air filter ZT/ZR110-275 Dp air filter ZR300-750 Delay at signal, Dp air filter hr hr hr hr hr mbar mbar sec -50 -58 0 Nominal 4000 8000 16000 40000 2000 -44 -52 60 -44 -52 255 Maximum
2920 1478 01
59
Instruction book
2920 1478 01
60