Codigos Error AIX - Sa76-0089
Codigos Error AIX - Sa76-0089
Codigos Error AIX - Sa76-0089
Power Systems
Note Before using this information and the product it supports, read the information in Notices on page 567 and the IBM Systems Safety Information manual, G229-9054.
Fifth Edition (April 2008) This edition applies to IBM PowerTM Systems servers that contain the POWER6TM processor and to all associated models. This edition replaces SA76-0089-03. Copyright International Business Machines Corporation 2007, 2008. All rights reserved. US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
Contents
Safety and environmental notices . . . . . . . . . . . . . . . . . . . . . . . . v About this publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
How to send your comments . . . . . . . Reference codes that begin with a number sign (#) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix . ix
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. 291 . 292
iii
(433x) Disk drive reference codes . . . . (4758) Reference codes . . . . . . . (4685) Tape unit reference codes . . . . (4764) Reference codes . . . . . . . (4812) Reference codes . . . . . . . (4B20) Model 185 and A50 reference (error)
. . . . . . . . . . codes
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
iv
CAUTION: Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the following information: laser radiation when open. Do not stare into the beam, do not view directly with optical instruments, and avoid direct exposure to the beam. (C030)
Power and cabling information for NEBS (Network Equipment-Building System) GR-1089-CORE
The following comments apply to the IBM servers that have been designated as conforming to NEBS (Network Equipment-Building System) GR-1089-CORE: The equipment is suitable for installation in the following: v Network telecommunications facilities v Locations where the NEC (National Electrical Code) applies The intrabuilding ports of this equipment are suitable for connection to intrabuilding or unexposed wiring or cabling only. The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP (outside plant) or its wiring. These interfaces are designed for use as intrabuilding interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require isolation from the exposed OSP cabling. The addition of primary protectors is not sufficient protection to connect these interfaces metallically to OSP wiring. Note: All Ethernet cables must be shielded and grounded at both ends. The ac-powered system does not require the use of an external surge protection device (SPD). The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground.
Note: This mark applies only to countries within the European Union (EU) and Norway. Appliances are labeled in accordance with European Directive 2002/96/EC concerning waste electrical and electronic equipment (WEEE). The Directive determines the framework for the return and recycling
vi
of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive.
In accordance with the European WEEE Directive, electrical and electronic equipment (EEE) is to be collected separately and to be reused, recycled, or recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and recovery of WEEE. Customer participation is important to minimize any potential effects of EEE on the environment and human health due to the potential presence of hazardous substances in EEE. For proper collection and treatment, contact your local IBM representative.
vii
Note: This mark applies only to countries within the European Union (EU). Batteries or packaging for batteries are labeled in accordance with European Directive 2006/66/EC concerning batteries and accumulators and waste batteries and accumulators. The Directive determines the framework for the return and recycling of used batteries and accumulators as applicable throughout the European Union. This label is applied to various batteries to indicate that the battery is not to be thrown away, but rather reclaimed upon end of life per this Directive.
In accordance with the European Directive 2006/66/EC, batteries and accumulators are labeled to indicate that they are to be collected separately and recycled at end of life. The label on the battery may also include a chemical symbol for the metal concerned in the battery (Pb for lead, Hg for mercury and Cd for cadmium). Users of batteries and accumulators must not dispose of batteries and accumulators as unsorted municipal waste, but use the collection framework available to customers for the return, recycling, and treatment of batteries and accumulators. Customer participation is important to minimize any potential effects of batteries and accumulators on the environment and human health due to the potential presence of hazardous substances. For proper collection and treatment, contact your local IBM representative. For California: Perchlorate Material - special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate. The foregoing notice is provided in accordance with California Code of Regulations Title 22, Division 4.5 Chapter 33. Best Management Practices for Perchlorate Materials. This product, part, or both may include a lithium manganese dioxide battery which contains a perchlorate substance.
viii
ix
Servicer Response: No action required. This reference code is logged for information only. If this reference code is present for more than 1 minute, follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 100000AA Download in process
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD CBLALL 10001503 Power supply failure
Servicer Response: No action required. This reference code is logged for information only. 100000AC Detected AC loss
Servicer Response: If system powers on normally or stays powered on after AC power failure, no replacement of parts may be needed. If parts are replaced, follow the instructions for the items listed in the FRU List. FRU List: ACMODUL 100000AD A reset of the service processor caused the system to power off. Detected AC loss
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001510 Detected AC loss
10001500
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct, follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001501 Power supply failure
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct, follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001511 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List:
Copyright IBM Corp. 2007, 2008
10001512 10001524
10001512 Power supply failure 10001520 Detected AC loss
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct, follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
CBLALL 10001521 10001513 Power supply failure Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001522 10001514 Power supply failure Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD CBLALL 10001516 No Power Supplies Present 10001523 Power supply failure Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001517 Power supply failure 10001524 Power supply failure Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD Power supply failure Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: The required power supplies are not installed. Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
10001526 10001F02
10001526 No Power Supplies Present 10001533 Power supply failure
Servicer Response: The required power supplies are not installed. Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001527 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001B01 Load fault on the +12V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 10001530 Detected AC loss
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10001B02 Load fault on the +5V bus
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct. Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10001B03 Load fault on the +3.3V bus
10001531
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10001B04 Load fault on the -12V bus
10001532
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD CBLALL
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10001F02 SPCN trace information saved
Servicer Response: No action required. This reference code is logged for information only.
10002600 10003102
10002600 Power Good Fault 10002608 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PGDPART 10002601 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10002609 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PGDPART 10002603 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10002612 Optical Converter 5V Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PGDPART 10002605 Power Good Fault
Servicer Response: The SPCN detected a fault on the SPCN card optical converter 5V. Follow the instructions for the items listed in the FRU List. FRU List: CBLALL TWRCARD 10003100 I2C Bus Controller Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10002606 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003101 I2C Bus 1 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 10002607 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003102 I2C Bus 2 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List:
10003103 10003113
I2CBUS TWRCARD 10003103 I2C Bus 3 Communication fault 1000310B I2C Bus SPCN VPD Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003110 I2C Bus DASD Backplane 1 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003104 I2C Bus 4 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003105 I2C Bus 5 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003111 I2C Bus DASD Backplane 2 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003112 I2C Bus DASD Backplane 3 Communication fault
10003106
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 1000310A I2C Bus SPCN VPD Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003113 I2C Bus Adapter Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
10003114 10004600
10003114 I2C Bus PCI Backplane Communication fault 10003122 I2C Bus SPCN VPD Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003115 I2C Bus Panel Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD 10003123 I2C Bus SPCN VPD Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
10003116
10003124
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
10003118
10003125
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
10003121
I2C Bus 2 Communication fault 10004600 UPS Interface Failure Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: UPSUNIT TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
10004601 10007650
10004601 UPS Interface Failure 10007630 Fan Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: UPSUNIT TWRCARD 10007610 Fan Fault
Servicer Response: The Fan is operating at the wrong speed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007631 Fan missing error
Servicer Response: The Fan is operating at the wrong speed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007611 Fan missing error
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007640 Fan Fault
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007620 Fan Fault
Servicer Response: The Fan is operating at the wrong speed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007641 Fan missing error
Servicer Response: The Fan is operating at the wrong speed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007621 Fan missing error
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 10007650 Fan Fault
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD
10007651 10008943
10007651 Fan missing error 10008920 External Netfinity Server Power Good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD ALTMANL
10008400
No VPD Found due to Invalid Bypass 10008930 Integrated Netfinity Adapter fault Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD Unable to Collect VPD 10008940 External Netfinity Server R485 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1917 10008402
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 1000840D SPCN Configuration mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL 10008941 External Netfinity Server R485 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: IDPART TWRCARD 1000840E SPCN Default Configuration loaded
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL 10008942 External Netfinity Server R485 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: IDPART TWRCARD 10008910 External Netfinity Server 3.3V fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL 10008943 External Netfinity Server R485 Communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: ALTMANL TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List.
10
10008A00 10009019
FRU List: TWRCARD CBLALL 10008A00 IO Power control changed to another system unit 10009015 An invalid rack command was encountered.
Servicer Response: No action required. This reference code is logged for information only. 10009002 Received a bad return code
Servicer Response: Informational message: The command is invalid for the addressed rack and has not been executed. This status is also returned if the address mode is not valid for the command. The information found in this error log entry may be used by product engineering to debug system power control network (SPCN) failures. 10009016 A command to an SPCN node was rejected.
Servicer Response: Partition Firmware has detected a condition that may require attention. Check error log for other errors that may have been reported at the same time as this condition was reported. If this SRC persists contact next level of support. 10009012 Address not valid.
Servicer Response: No action required. This reference code is logged for information only. 10009018 An invalid modifier was found in a command.
Servicer Response: LIC command had a frame address that was not valid. Exchange the SPCN frame-to-frame cables to the failing frame. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL 10009013 Invalid Node Address.
Servicer Response: Informational message: This status is used by the slave, rack and CEC to identify invalid command modifier values in commands directed to the node. An APX command will be rejected by the CEC without transmission on the network if the modifier field contains an invalid address. The information found in this error log entry may be used by product engineering to debug system power control network (SPCN) failures. 10009019 An invalid command was encountered.
Servicer Response: The address in the SPCN command does not match the secondary nodes assigned address. Exchange the failing items for the SPCN node reporting the error. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL 10009014 A command has an invalid address mode.
Servicer Response: Informational message: The command is not valid for transmission on the network. The following conditions are detected by the CEC node during hypervisor command processing. The command is rejected directly by the CEC node for the following reasons: v The command from the hypervisor was not defined. v The RPF or RPN command from the hypervisor specified R = 0. (Programming cannot power the system off via this mechanism). v The LSP subset command (0x1X) was not addressed to a specific node. v The APX command was not addressed to RRRR=01-3FFF, UU=0. v A QSX command was not addressed to RRRR=0 , UU=D. The information found in this error log entry may be used by product engineering to debug system power control network (SPCN) failures.
Servicer Response: A command from the system unit specified a unit address of D or E or had a frame address of 00. Exchange the failing items in the system unit. Follow the instructions for the items listed in the FRU List. FRU List: AJDG301 TWRCARD
11
1000901B 10009035
1000901B A CEC port addressing problem was found. 10009029 SPCN VPD Damaged
Servicer Response: Informational message: This status is inserted by the primary rack on broadcast commands to identify the location of the CEC node. This response is returned to node specific commands addressed to the CEC node using the CEC physical RRRRUU value. The CEC cannot be addressed with this address. The information found in this error log entry may be used by product engineering to debug system power control network (SPCN) failures. 10009021 A command to an SPCN node was rejected.
Servicer Response: The VPD record in the EEPROM has bad data. Exchange the failing items for the node reporting the failure. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 1000902D Addressed frame is not in SPCN configuration table.
Servicer Response: No action required. This reference code is logged for information only. 10009022 Addressed Unit not in frame.
Servicer Response: The addressed frame is not in the SPCN configuration table. No action required. This reference code is logged for information only. 10009031 Frame-to-Frame Communications Failure
Servicer Response: The addressed unit does not exist in the addressed frame. No action required. This reference code is logged for information only. 10009023 Addressed Unit exists, but the frame is powered off.
Servicer Response: The SPCN detected a BCC error on a transmission from another frame. The transmission is attempted again. No action required. This reference code is logged for error analysis only. 10009032 SPCN Communications Failure, unit to rack.
Servicer Response: The addressed unit is in a frame that is powered off. No action required. This reference code is logged for information only. 10009024 SPCN Licensed Internal Code not valid.
Servicer Response: The frame detected a BCC error on a transmission from a secondary node to the frame. The transmission is attempted again. No action required. This reference code is logged for error analysis only. 10009033 SPCN Communications Failure, rack to unit.
Servicer Response: The Licensed Internal Code in one of the secondary nodes is not valid. The code will be reloaded. No action required. This reference code is logged for error analysis only. 10009025 SPCN Licensed Internal Code is not valid.
Servicer Response: A secondary node detected a BCC error on a transmission from the frame. The transmission is attempted again. No action required. This reference code is logged for error analysis only. 10009034 Unsupported Packet Size
Servicer Response: The Licensed Internal Code in one of the frames is not valid. The code will be reloaded. No action required. This reference code is logged for error analysis only. 10009028 SPCN Licensed Internal Code is not valid.
Servicer Response: The receiving node detected a packet exceeding 70 bytes. The frame can also return this code if a secondary node returns more than 10 bytes to a PAS command. No action required. This reference code is logged for error analysis only. 10009035 Secondary SPCN node timeout.
Servicer Response: The Licensed Internal Code in the primary node is not valid. The code will be reloaded. No action required. This reference code is logged for error analysis only.
Servicer Response: A secondary SPCN node did not respond to a command. The command was attempted again and failed. No action required. This reference code is logged for error analysis only.
12
10009036 100090F0
10009036 Frame Timeout 10009047 QDS Block Sequence Error
Servicer Response: One or more frames did not respond to a command. The command is attempted again. No action required. This reference code is logged for error analysis only. 1000903B Invalid Packet Length for data sent.
Servicer Response: The Block Sequence number is wrong. The download was stopped. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009048 The SPCN ROS and EEPROM LIC is not compatible.
Servicer Response: The number of bytes sent or received does not match the number of bytes specified in the command. No action required. This reference code is logged for error analysis only. 10009041 Invalid Load Type
Servicer Response: The down load was successful, but the wrong type of Licensed Internal Code was loaded. The operation was attempted again but was not successful. Exchange the failing items for the node reporting the fault. Follow the instructions for the items listed in the FRU List. FRU List: AJDG301 TWRCARD 10009042 EEPROM Failure
Servicer Response: The LIC levels in the nodes ROS and EEPROM are not compatible. Exchange the failing items for the failing node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD AJDG301 10009080 Undefined Status Code
Servicer Response: An SPCN node returned an unknown status code. Exchange the failing SPCN node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD SYSBKPL 10009088 A problem was found in the SPCN firmware.
Servicer Response: The EEPROM in an SPCN node cannot be written successfully. Exchange the SPCN node reported in the failure. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009043 Download Failure
Servicer Response: The Licensed Internal Code download to an SPCN node was completed but was not successful. Exchange the failing SPCN node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009046 QDS Packet Sequence Error
Servicer Response: Informational message: A problem was found in the SPCN firmware. The information found in this error log entry may be used by product engineering to debug system power control network (SPCN) failures. 100090F0 A frame was dropped from the SPCN configuration.
Servicer Response: A frame was dropped from the SPCN configuration. This is usually caused by a loss of ac power or a problem with the frame-to-frame cable. Follow the instructions for the items listed in the FRU List. FRU List: PWR1907 TWRCARD CBLALL
Servicer Response: The Packet Sequence number is wrong. The download was stopped. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD
13
100090F1 10009111
100090F1 A frame was added to the SPCN configuration. 10009105 Load Damaged Timeout
Servicer Response: No action required. This reference code is logged for information only. 100090F2 Slave disappeared
Servicer Response: An SPCN node failed to enter the operational state. Exchange the failing SPCN node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009106 An SPCN LID was not found.
Servicer Response: A slave was dropped from the SPCN configuration. This is usually caused by a loss of ac power. 100090F3 Slave reappeared
Servicer Response: No action required. This reference code is logged for information only. 10009107 An SPCN microcode download is required.
Servicer Response: No action required. This reference code is logged for information only. 10009101 VLIC-SPCN Timeout
Servicer Response: A Licensed Internal Code timeout occurred. The SPCN failed to respond to a Licensed Internal Code command. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009102 Assign Permanent Address command failure
Servicer Response: No action required. This reference code is logged for error analysis only. 10009108 A status change occurred in one of the SPCN nodes.
Servicer Response: No action required. This reference code is logged for information only. 10009109 Licensed Internal Code part number is not correct.
Servicer Response: A node failed to perform an Assign Permanent Address command. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009103 Download Initialize Timeout
Servicer Response: The AROS part number field was not updated to the correct level after the system attempted to load new Licensed Internal Code. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 1000910A RIO Download Required
Servicer Response: An SPCN node failed to enter the download state after an Initialize for Download command. Exchange the failing SPCN node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009104 Download Completion Timeout
Servicer Response: No action required. This reference code is logged for information only. 1000910B Maximum number of retries exceeded
Servicer Response: No action required. This reference code is logged for information only. 10009111 SPCN is too large for hypervisor.
Servicer Response: An SPCN node failed to leave the download state. Exchange the failing SPCN node. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD
Servicer Response: There are more nodes in the network than the hypervisor can service. Go to System Configuration in ASMI. Under Configure I/O Enclosures select Clear
14
10009112 1000911E
Inactive Enclosures. If the error persists follow the instructions for the items listed in the FRU List. FRU List: AJDG301 10009112 Primary SPCN node is reporting load damaged. 10009118 Hypervisor out of memory
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: AJDG301 10009119 NVRAM Write Failed
Servicer Response: The Licensed Internal Code for the primary SPCN node is damaged. The reload failed because the code could not be found. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009113 Secondary SPCN node is reporting load damaged.
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 1000911A Too many racks attached
Servicer Response: The Licensed Internal Code for the secondary SPCN node is damaged. The reload failed because the code could not be found. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009114 Frame SPCN node is reporting load damaged.
Servicer Response: Reduce the number of racks to maximum configuration on the system. 1000911B SPCN CEC node code failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: AJDG301 1000911C Two nodes have same VPD
Servicer Response: The Licensed Internal Code for a SPCN node is damaged. The reload failed because the code could not be found. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD 10009115 SPCN Command rejected by the Firmware.
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART 1000911D RIO Download Failure
Servicer Response: The service processor rejected an SPCN command from the Licensed Internal Code. No action required. This reference code is logged for information only. 10009116 SPCN - Control Panel interface failure.
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD SI_CARD 1000911E Temporary VPD written
Servicer Response: The SPCN to control panel interface is not working. 10009117 SPCN - Control Panel interface is now working.
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRVPD
Servicer Response: The SPCN to control panel interface is now working. No action required. This reference code is logged for information only.
15
1000911F 100091FB
1000911F CEC not found 10009137 Bad PCI Correlation Problem
Servicer Response: Call your next level of support. 10009120 Duplicate backplane VPD
Servicer Response: SPCN node not matched Follow the instructions for the items listed in the FRU List. FRU List: CBLALL 10009138 Bad Location Code
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SYSBKPL 10009131 Invalid XM Return Code
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: CBLALL 10009139 Open SPCN loop resolved
Servicer Response: No action required. Logged for error analysis only. 10009132 Node contains temporary VPD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRVPD 10009133 Bad PCI Correlation Problem
Servicer Response: No action required. This reference code is logged for information only. 1000913A RIO download sent retry
Servicer Response: No action required. This reference code is logged for information only. 1000913B Go to ASMi to start a download manually
Servicer Response: PCI bus not matched Follow the instructions for the items listed in the FRU List. FRU List: CBLALL 10009134 PCI bus VPD error
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1907 100091DD All SPCN Downloads Complete
Servicer Response: Check Error Log for B700 xxxx Reference Codes. 10009135 Open SPCN Loop
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: CBLALL TWRCARD 10009136 The manually started download was interrupted
Servicer Response: No action required. This reference code is logged for information only. 100091DE RIO Download Complete
Servicer Response: No action required. This reference code is logged for information only. 100091FB Write VPD on next IPL
Servicer Response: No action required. This reference code is logged for information only.
16
1000C62E 11001521
1000C62E SPCN Network Fault 1000CB15 EEPROM Failure.
Servicer Response: An SPCN frame-to-frame communication failure was detected. Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD CBLALL
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD
Servicer Response: If system powers on normally or stays powered on after AC power failure, no replacement of parts may be needed. FRU List: PWR1912 110000AD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Perform action found in FRU list. FRU List: TWRCARD 11001510 Detected AC loss
11001514
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct. Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11001520 Detected AC loss
11001511
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11001512 Power supply failure
Servicer Response: Before replacing any parts, verify that the AC input voltage is correct. Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11001521 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List.
Servicer Response: Follow the instructions for the items listed in the FRU List.
Chapter 2. 1xxx Reference Codes
17
11001522 11001632
FRU List: PWRSPLY TWRCARD 11001522 Power supply failure 11001613 Regulator 1 Domain Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001621 Regulator 2 Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD CBLALL 11001523 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001622 Regulator 2 Communication Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11001524 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001623 Regulator 2 Domain Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11001611 Regulator 1 Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001631 Regulator 3 Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001612 Regulator 1 Communication Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001632 Regulator 3 Communication Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918
18
11001633 11001C12
TWRCARD 11001633 Regulator 3 Domain Fault TWRCARD 11001B0A Load Fault on the +12V/-12v bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11001B01 Level 1 load fault (+12V)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001B0F Load Fault on the +1.2V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 11001B02 Load fault on the +5V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001C10 Regulator Level 1 Load Fault (1.1A)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 11001B03 Load fault on the +3.3V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001C11 Regulator Level 2 Load Fault (1.1B)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1900 TWRCARD 11001B05 Load fault on the +1.8V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001C12 Regulator Level 2 Load Fault (1.8)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001B06 Load fault on the +2.5V bus
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904
Chapter 2. 1xxx Reference Codes
19
11001C13 11001D14
11001C13 Regulator Level 2 Load Fault (1.2A) CARDFLT 11001D04 Lightstrip (front) fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD
Servicer Response: Perform action found in the FRU list. FRU List: LITSTRP CABLEH
11001C14
Regulator Level 2 Load Fault (1.25) 11001D05 Lightstrip (rear) fault Servicer Response: Perform action found in the FRU list. FRU List: LITSTRP CABLEH Regulator Level 2 Load Fault (1.2B) 11001D10 Node controller card fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001C15
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1904 TWRCARD 11001D00 Primary system controller card fault
Servicer Response: Perform action found in the FRU list. FRU List: NODECR 11001D11 Node controller card fault
Servicer Response: Perform action found in the FRU list. FRU List: NODECR 11001D12 I/O hub card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D01 Secondary system controller card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D13 I/O hub card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D02 Clock card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D14 I/O hub card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D03 Clock card fault
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT
Servicer Response: Perform action found in the FRU list. FRU List:
20
11001D15 11002613
11001D15 I/O hub card fault 11001F02 SPCN trace information saved
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11001D60 RIO Adapter Card 1 Softswitch fault
Servicer Response: No action required. This reference code is logged for information only. 11002600 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SI_CARD TWRCARD 11001D63 RIO Adapter Card 2 Softswitch fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PGDPART 11002602 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11002603 Power Good Fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SI_CARD TWRCARD 11001E00 Informational message: open failure log only
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PGDPART 11002610 A power signal failure has been detected
Servicer Response: No action required 11001E01 Informational message: pin failure log only
Servicer Response: No action required 11001E02 Informational message: close failure log only
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SYSBKPL 11002611 A power signal failure has been detected
Servicer Response: No action required 11001E03 Informational message: pin failure log only
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SYSBKPL 11002613 100V check fault
Servicer Response: No action required 11001F01 TMS limit reached - log only
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: CBLALL
Chapter 2. 1xxx Reference Codes
21
11002620 11002640
SYSBKPL 11002620 12V power-good input fault PWR1918 ANYPROC SYSBKPL 11002632 Processor 1 VRM2 array power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SYSBKPL 11002622 1.52V power-good input fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 11002623 1.8V power-good input fault
11002633
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 11002624 5.0V power-good input fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 SYSBKPL 11002634 Processor 1 1.8V VRM or processor 1 power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 11002625 3.3V power-good input fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: ANYPROC SYSBKPL 11002640 2.5V power-good input fault Processor 2 VRM 1A or 1B power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 11002626
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 11002630 Processor 1 VRM 1A or 1B power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List:
22
11002641 11002660
11002641 Processor 2 VRM 1A or 1B power-good fault 11002650 Processor 3 VRM 1A or 1B power-good fault
Servicer response: Follow the instructions for the items listed in the FRU list. FRU List: PWR1918
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC
ANYPROC
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL 11002653 Processor 3 1.2V VRM power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL 11002643 Processor 2 1.8V VRM or processor 2 power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 SYSBKPL 11002654 Processor 3 1.8V VRM or processor 3 power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: ANYPROC SYSBKPL 11002644 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: ANYPROC SYSBKPL 11002660 Processor 4 VRM 1A or 1B power-good fault
Servicer response: Perform action found in the FRU list. FRU List: DCA
ANYPROC
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC
Chapter 2. 1xxx Reference Codes
SYSBKPL
23
11002662 11004600
SYSBKPL 11002662 Processor 4 VRM2 array power-good fault 11003114 Service processor I2C failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS SYSBKPL TWRCARD
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL 11002663 Processor 4 1.2V VRM power-good fault
11003116
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: SYSBKPL 11003120 VRM failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 SYSBKPL 11002664 Processor 4 1.8V VRM or processor 4 power-good fault
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 ANYPROC SYSBKPL 11004201 UPS Reported, Utility Failure On
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: ANYPROC SYSBKPL 11003100 Service processor I2C failure
Servicer Response: No action required. This reference code is logged for information only. 11004202 Informational message: uninterruptible power supply (UPS) battery low (not EPOW4)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: I2CBUS TWRCARD
11003105
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: TWRCARD
Servicer Response: No action required. This reference code is logged for information only. 11004600 UPS Interface Failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: UPSUNIT
24
11004601 11007211
TWRCARD 11004601 UPS Interface Failure 11007120 Power supply failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: UPSUNIT TWRCARD 11005000 Primary system controller configuration check failure
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11007201 Ambient temperature is out of range
Servicer Response: Follow the procedure for the items listed in the FRU List. FRU List: AMBTEMP 11007202 Ambient temperature is back in range
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11005000 Primary system controller configuration check failure
Servicer Response: No action required. This reference code is logged for information only. 11007203 Ambient temperature exceeded limit
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11005001 Invalid processor vital product data (VPD)
Servicer Response: The system will shut down in 15 minutes. Follow the instructions for the items listed in the FRU List. FRU List: AMBTEMP 11007204 The ambient temperature is back in range.
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT CARDFLT CARDFLT CARDFLT 11005001 Invalid processor vital product data (VPD)
Servicer Response: No action required. This reference code is logged for information only. 11007205 Ambient temperature exceeded limit
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT CARDFLT CARDFLT CARDFLT 11007110 Power supply failure
Servicer Response: The system will shut down in 20 seconds. Follow the instructions for the items listed in the FRU List. FRU List: AMBTEMP 11007211 Ambient temperature is out of range
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
Servicer Response: Ambient Temperature is above nominal for CPU performance. Follow the instructions for the items listed in the FRU List. FRU List: AMBTMP1
25
11007212 11007641
11007212 Ambient temperature is back in range AIRMOVR TWRCARD 11007630 A fan is operating at the wrong speed.
Servicer Response: Ambient Temperature has returned to nominal. Follow the instructions for the items listed in the FRU List. FRU List: AMBTMP2 11007610 Fan Fault
Servicer Response: Ensure the fans, and fan tray are fully seated into the fan connectors. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007631 A problem was detected with a fan which can be caused by a fan not being installed.
Servicer Response: The Fan is operating at the wrong speed. Ensure the fans, and fan tray, are fully seated into the fan connectors. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007611 Fan missing error
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Ensure the fans, and fan tray are fully seated into the fan connectors. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007620 Fan Fault
Servicer Response: Ensure the fans, and fan tray are fully seated into the fan connectors. Install the fan if it is missing; replace it if already installed. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007640 A fan is operating at the wrong speed.
Servicer Response: Ensure the fans, and fan tray are fully seated into the fan connectors. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007641 A problem was detected with a fan which can be caused by a fan not being installed.
Servicer Response: The Fan is operating at the wrong speed. Ensure the fans, and fan tray are fully seated into the fan connectors. Follow the instructions for the items listed in the FRU List. FRU List: AIRMOVR TWRCARD 11007621 Fan missing error
Servicer Response: Ensure the fans, and fan tray are fully seated into the fan connectors. Install the fan if it is missing; replace it if already installed. Follow the instructions for the items listed in the FRU list. FRU List: AIRMOVR TWRCARD
Servicer Response: A problem was detected with a Fan which can be caused by a Fan not being installed. Ensure the fans, and fan tray are fully seated into the fan connectors. Install Fan if missing, replace if already installed. Follow the instructions for the items listed in the FRU List. FRU List:
26
11008400 11008414
11008400 No VPD Found due to Invalid Bypass 11008410 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: AJDG301 11008402 Unable to Collect VPD
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART 11008411 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 11008404 Processor Unit VPD Mismatch
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008412 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 11008405 Processor Unit VPD Mismatch
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008413 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 11008406 Processor Unit VPD Mismatch
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008413 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 11008409 No Processor Installed
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008414 Invalid processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT
Chapter 2. 1xxx Reference Codes
27
11008414 11008424
11008414 Invalid processor vital product data (VPD) CARDFLT 11008420 No processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART 11008421 No processor vital product data (VPD)
11008415
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008422 No processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008415 Invalid processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008423 No processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008416 Invalid processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008423 No processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008416 Invalid processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008424 No processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008417 Invalid processor vital product data (VPD)
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART
28
11008424 11008471
11008424 No processor vital product data (VPD) 11008452 Wrong power supply installed.
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD
11008425
No processor vital product data (VPD) 11008455 Power Supply Missing Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY No processor vital product data (VPD) TWRCARD 11008456 Power Supply Missing
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008426
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008427 No processor vital product data (VPD)
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWRSPLY TWRCARD 11008460 All PWR nodes guarded
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008450 SPCN Configuration mismatch
Servicer Response: No action required. This reference code is logged for information only. 11008470 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD 11008451 SPCN Configuration mismatch
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART 11008471 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: PWR1918 TWRCARD
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT
29
11008472 11008701
11008472 Processor vital product data (VPD) mismatch CARDFLT 110084A1 Invalid Power Distribution Backplane VPD
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008473 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 110084A2 Power Distribution Backplane Mismatch
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008474 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 110084A3 Invalid service processor card VPD
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008475 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 110084A4 Service processor card mismatch.
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008476 Processor vital product data (VPD) mismatch
Servicer Response: Follow the instructions for the items listed in the FRU List. FRU List: VPDPART TWRCARD 11008700 Bulk power controller (BPC) A AC loss
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART CARDFLT 11008477 Processor vital product data (VPD) mismatch
Servicer Response: Perform action found in the FRU list. FRU List: PWR2402 11008701 Bulk power controller (BPC) B AC loss
Servicer Response: Perform action found in the FRU list. FRU List: VPDPART
Servicer Response: Perform action found in the FRU list. FRU List: PWR2402
30
11008710
11008710 Distributed converter assembly (DCA) 1 universal asynchronous receive/transmitter (UART) communication fault CARDFLT SYSBP 11008714
11008717
Servicer Response: Perform action found in the FRU list. FRU List: DCA CARDFLT SYSBP 11008711 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008715 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008712 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008716 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008713 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008717 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR
Servicer Response:
Chapter 2. 1xxx Reference Codes
31
11008718 1100871E
Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008718 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault 1100871B Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 1100871C Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008719 Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 1100871D Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 1100871A Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 1100871E Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR
32
1100871F 11008734
CARDFLT SYSBP 1100871F Distributed converter assembly (DCA) universal asynchronous receive/transmitter (UART) communication fault 11008725 Bulk power controller (BPC) B MTMS (machine type/model, serial number) mismatch
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH BPC CARDFLT 11008731 Bulk power controller (BPC) critical fault: none of the processor nodes are powered on.
Servicer Response: Perform action found in the FRU list. FRU List: DCA NODECR CARDFLT SYSBP 11008720 Bulk power controller (BPC) A Ethernet communication fault
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH NEXTLVL 11008732 Bulk power controller (BPC) critical fault: there is a CEC cage ID mismatch due to a cabling error.
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH BPC CARDFLT 11008721 Bulk power controller (BPC) B Ethernet communication fault
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH NEXTLVL 11008733 Bulk power controller (BPC) critical fault: no node books are present in the system to be powered on.
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH BPC CARDFLT 11008724 Bulk power controller (BPC) A MTMS (machine type/model, serial number) mismatch
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH NEXTLVL 11008734 Bulk power controller (BPC) critical fault: service processor error log collection failed.
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH BPC CARDFLT
Servicer Response: Perform action found in the FRU list. FRU List: CABLEH NEXTLVL
33
11008735 14010079
11008735 Service processor fault; no bulk power controller (BPC) IP addresses Perform action found in the FRU list. FRU List: BPC 11008741 Bulk power controller (BPC) B fault; failed to reach standby
Servicer Response: Perform action found in the FRU list. FRU List: CARDFLT 11008740 Bulk power controller (BPC) A fault; failed to reach standby
Servicer Response: Perform action found in the FRU list. FRU List: BPC
Servicer Response:
34
1401007A 14010084
1401007A A fault has been detected on MCM1 in the processor node indicated in failure information. BPR-2A BPR-3A CBL-PWRC-BPE-A1-PWR BPC-A BPE-BOARD-A A fault has been detected on MCM2 in the processor node indicated in failure information. 14010082 FRU List: BPR-1B BPR-2B BPR-3B CBL-PWRC-BPE-B1-PWR 1401007C A fault has been detected on MCM3 in the processor node indicated in failure information. BPC-B BPE-BOARD-B 14010083 FRU List: BPR-4A LGA shorts test has failed. BPR-5A BPR-6A CBL-PWRC-BPE-A2-PWR BPC-A The LGA shorts test has failed. BPE-BOARD-A 14010084 FRU List: BPR-4B BPR-5B 1401007E There is a problem with sensed and passed configuration of the MCMs that are installed in the system. Input power to BPA A has been lost or partially lost. BPR-6B CBL-PWRC-BPE-B2-PWR 14010081 FRU List: BPR-1A BPC-B BPE-BOARD-B Input power to BPA A has been lost or partially lost. Input power to BPA A has been lost or partially lost. The input power to BPA B has been lost or partially lost.
Servicer Response: See the power fault reason code for additional information and contact your next level of support. FRU List: MCM1 1401007B
Servicer Response: See the power fault reason code for additional information and contact your next level of support. FRU List: MCM2
Servicer Response: See the power fault reason code for additional information and contact your next level of support. FRU List: MCM3 1401007D FRU List: MCM1 MCM2 ANY-NODE 1401007F FRU List: MCM1 MCM2 ANY-NODE
35
14010085 14010210
14010085 The thermal sensor(s) on a processor node has indicated a thermal problem, and one or more DCAs has shut down. 14010112 The voltage on the voltage level 11 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on the voltage level 13 has reached the warning undervoltage limit for the specified cage or drawer. There has been an internal bulk power software error. The voltage on voltage level 1 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 2 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 3 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 4 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 5 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 6 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 7 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 8 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 9 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 10 has reached the warning over voltage limit for the specified cage or drawer.
FRU List: NEXTLVL 14010101 The voltage on voltage level 1 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 2 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 3 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 4 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 5 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 6 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 7 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 8 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on voltage level 9 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on the voltage level 10 has reached the warning undervoltage limit for the specified cage or drawer. The voltage on the voltage level 11 has reached the warning undervoltage limit for the specified cage or drawer.
14010113
14010135
14010102
14010201
14010103
14010202
14010104
14010203
14010105
14010204
14010106
14010205
14010107
14010206
14010108
14010207
14010109
14010208
14010110
14010209
14010111
14010210
36
14010211 14010401
14010211 The voltage on voltage level 11 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 12 has reached the warning over voltage limit for the specified cage or drawer. The voltage on voltage level 13 has reached the warning over voltage limit for the specified cage or drawer. An over current condition has been detected on voltage level 1 for the specified cage or drawer. 14010307 An over current condition has been detected for voltage level 7 for the specified cage or drawer.
14010212
FRU List: FRULEVEL7 14010308 An over current condition has been detected for voltage level 8 for the specified cage or drawer.
14010213
FRU List: FRULEVEL8 14010309 An over current condition has been detected for voltage level 9 for the specified cage or drawer.
14010301
FRU List: FRULEVEL1 14010302 An over current condition has been detected for voltage level 2 for the specified cage or drawer.
FRU List: FRULEVEL9 14010310 An over current condition has been detected for voltage level 10 for the specified cage or drawer.
FRU List: FRULEVEL2 14010303 An over current condition has been detected for voltage level 3 for the specified cage or drawer.
FRU List: FRULEVEL10 14010311 An over current condition has been detected for voltage level 11 for the specified cage or drawer.
FRU List: FRULEVEL3 14010304 An over current condition has been detected for voltage level 4 for the specified cage or drawer.
FRU List: FRULEVEL11 14010312 An over current condition has been detected for voltage level 12 for the specified cage or drawer.
FRU List: FRULEVEL4 14010305 An over current condition has been detected for voltage level 5 for the specified cage or drawer.
FRU List: FRULEVEL12 14010313 An over current condition has been detected for voltage level 13 for the specified cage or drawer.
FRU List: FRULEVEL5 14010306 An over current condition has been detected for voltage level 6 for the specified cage or drawer.
FRU List: FRULEVEL13 14010401 An over voltage condition has been detected for voltage level 1 for the specified cage or drawer.
37
14010402 14011307
14010402 An over voltage condition has been detected for voltage level 2 for the specified cage or drawer. 14010410 An over voltage condition has been detected for voltage level 10 for the specified cage or drawer.
FRU List: FRULEVEL2 14010403 An over voltage condition has been detected for voltage level 3 for the specified cage or drawer.
FRU List: FRULEVEL10 14010411 An over voltage condition has been detected for voltage level 11 for the specified cage or drawer.
FRU List: FRULEVEL3 14010404 An over voltage condition has been detected for voltage level 4 for the specified cage or drawer.
FRU List: FRULEVEL12 14010412 An over voltage condition has been detected for voltage level 12 for the specified cage or drawer. An over voltage condition has been detected for voltage level 13 for the specified cage or drawer.
FRU List: FRULEVEL4 14010405 An over voltage condition has been detected for voltage level 5 for the specified cage or drawer.
14010413
FRU List: FRULEVEL13 14011081 The VPD in CEC main storage can not be accessed or has a problem that is preventing the CEC from powering on.
FRU List: FRULEVEL5 14010406 An over voltage condition has been detected for voltage level 6 for the specified cage or drawer.
FRU List: FRUVPDMEMORY 14011082 VPD resolution failure in the cage or drawer.
FRU List: FRULEVEL6 14010407 An over voltage condition has been detected for voltage level 7 for the specified cage or drawer.
FRU List: FRUVPDBUS 14011301 14011302 The DASD backplane is defective. The IO planar is defective. This is a defective DASD on Backplane one. This is a defective DASD on Backplane two. This is a defective DASD on Backplane three. This is a defective DASD on Backplane four.
FRU List: FRULEVEL7 14010408 An over voltage condition has been detected for voltage level 8 for the specified cage or drawer.
14011304
FRU List: FRULEVEL8 14010409 An over voltage condition has been detected for voltage level 9 for the specified cage or drawer.
14011305
14011306
14011307
38
14011308 140121AC
14011308 14011309 14012051 FRU List: IO_DCA-01 14012052 DCA #2 is defective. This is a switch riser card. This is a switch PLANAR card. DCA number one is defective. FRU List: BPC-A 140120C2 The BPC on the A-side has detected an open UEPO loop. 140120C1 The UEPO switch on the BPC A-side is defective or in the BYPASS position. Switch to the NORMAL position.
Servicer Response: Informational only; no action is required. FRU list: IO_DCA-02 14012054 FRU List: BPF-A BPC-A 14012055 FRU List: BPF-B BPC-B 14012069 All DCAs reported No airflow in cage. Make sure that there are no blocked or dirty air inlet or filters. Verify that all unused logic positions are filled with filler books and that all circulation flaps inside affected Air Moving Enclosure are not blocked. The EPO panel or the cable between both BPCs and EPO panel is defective. The bulk power fan is defective in BPA-B. The bulk power fan is defective in BPA-A.
BPR-3A CBL-BPCA-EPO BPE-BOARD-A 14012152 FRU List: IO_DCA-02 1401218A A communication fault between BPC A and the load on port J08 (A) has been detected. DCA number two is defective.
FRU List: BPCA-PORT-08-A 1401219A A communication fault between BPC A and the load on port J09 (A) has been detected.
140120B9
FRU List: BPCA-PORT-09-A 140121AB A communication fault between BPC A and the load on port J10 (B) has been detected.
FRU List: BPCA-PORT-10-B 140121AC A communication fault between BPC A and the load on port J10 (C) has been detected.
39
140121BB 1401228A
140121BB A communication fault between BPC A and the load on port J11 (B) has been detected. 1401224A A communication fault between the BPD 1A and the load on port J04 (A) has been detected.
FRU List: BPCA-PORT-11-B 140121BC A communication fault between BPC A and the load on port J11 (C) has been detected.
FRU List: BPCA-PORT-11-C 140121C1 The UEPO switch on the BPC B-side is defective or in the BYPASS posistion. Switch to the NORMAL posistion.
FRU List: P2_CEC_DCA-02 1401225A A communication fault between the BPD 1A and the load on port J05 (A) has been detected.
FRU List: BPC-B 140121C2 The BPC on the B-side has detected an open UEPO loop.
FRU List: BPD1A-PORT-05-A 1401226A A communication fault between the BPD 1A and the load on port J06 (A) has been detected.
FRU List: BPD1A-PORT-06-A 1401227A A communication fault between the BPD 1A and the load on port J07 (A) has been detected.
FRU List: BPD1A-PORT-07-A 1401227B A communication fault between the BPD 1A and the load on port J07 (B) has been detected.
1401221A
A communication fault between the BPD 1A and the load on port J01 (A) has been detected.
FRU List: BPD1A-PORT-01-A 1401222A A communication fault between the BPD 1A and the load on port J02 (A) has been detected.
FRU List: BPD1A-PORT-07-B 1401227C A communication fault between the BPD 1A and the load on port J07 (C) has been detected.
FRU List: BPD1A-PORT-02-A 1401223A A communication fault between the BPD 1A and the load on port J03 (A) has been detected.
FRU List: BPD1A-PORT-07-C 1401228A A communication fault between the BPD 1A and the load on port J08 (A) has been detected.
40
1401228B 1401231A
1401228B A communication fault between the BPD 1A and the load on port J08 (B) has been detected. 14012301 Water cooling system number 1 has failed to cool adequately.
FRU List: BPD1A-PORT-08-B 1401228C A communication fault between the BPD 1A and the load on port J08 (C) has been detected.
Servicer Response: Informational only; no action is required. 14012302 Water cooling system number 2 has failed to cool adequately.
Servicer Response: Informational only; no action is required. 14012303 A problem with the water supply has been detected on water cooling system number 1.
FRU List: BPD1A-PORT-08-C 1401229A A communication fault between the BPD 1A and the load on port J09 (A) has been detected.
Servicer Response: Informational only; no action is required. 14012304 A problem with the water supply has been detected on water cooling system number 1.
FRU List: BPD1A-PORT-09-A 1401229B A communication fault between the BPD 1A and the load on port J09 (B) has been detected.
Servicer Response: Informational only; no action is required. 14012305 A leak has been detected on water cooling system number 1.
FRU List: BPD1A-PORT-09-B 1401229C A communication fault between the BPD 1A and the load on port J09 (C) has been detected.
Servicer Response: Informational only; no action is required. 14012306 A leak has been detected on water cooling system number 2.
FRU List: BPD1A-PORT-09-C 140122AA A communication fault between the BPD 1A and the load on port J10 (A) has been detected.
Servicer Response: Informational only; no action is required. 14012307 A valve problem has been detected on water cooling system number 1.
FRU List: BPD1A-PORT-10-A 140122AB A communication fault between the BPD 1A and the load on port J10 (B) has been detected.
Servicer Response: Informational only; no action is required. 14012308 A valve problem has been detected on water cooling system number 2.
FRU List: BPD1A-PORT-10-B 140122AC A communication fault between the BPD 1A and the load on port J10 (C) has been detected.
Servicer Response: Informational only; no action is required. 1401231A A communication fault between the BPD 2A and the load on port J01 (A) has been detected.
41
1401232A 140123AA
1401232A A communication fault between the BPD 2A and the load on port J02 (A) has been detected. 1401237C A communication fault between the BPD 2A and the load on port J07 (C) has been detected.
FRU List: BPD2A-PORT-02-A 1401233A A communication fault between the BPD 2A and the load on port J03 (A) has been detected.
FRU List: BPD2A-PORT-07-C 1401238A A communication fault between the BPD 2A and the load on port J08 (A) has been detected.
FRU List: BPD2A-PORT-03-A 1401234A A communication fault between the BPD 2A and the load on port J04 (A) has been detected.
FRU List: BPD2A-PORT-08-A 1401238B A communication fault between the BPD 2A and the load on port J08 (B) has been detected.
FRU List: BPD2A-PORT-08-B 1401238C A communication fault between the BPD 2A and the load on port J08 (C) has been detected.
FRU List: BPD2A-PORT-08-C 1401239A A communication fault between the BPD 2A and the load on port J09 (A) has been detected.
FRU List: P3_CEC_DCA-02 1401235A A communication fault between the BPD 2A and the load on port J05 (A) has been detected.
FRU List: BPD2A-PORT-09-A 1401239B A communication fault between the BPD 2A and the load on port J09 (B) has been detected.
FRU List: BPD2A-PORT-05-A 1401236A A communication fault between the BPD 2A and the load on port J06 (A) has been detected.
FRU List: BPD2A-PORT-09-B 1401239C A communication fault between the BPD 2A and the load on port J09 (C) has been detected.
FRU List: BPD2A-PORT-06-A 1401237A A communication fault between the BPD 2A and the load on port J07 (A) has been detected.
FRU List: BPD2A-PORT-09-C 140123AA A communication fault between the BPD 2A and the load on port J10 (A) has been detected.
FRU List: BPD2A-PORT-07-A 1401237B A communication fault between the BPD 2A and the load on port J07 (B) has been detected.
42
140123AB 14012A01
140123AB A communication fault between the BPD 2A and the load on port J10 (B) has been detected. 14012552 DCA number two is defective.
FRU List: BPD2A-PORT-10-B 140123AC A communication fault between the BPD 2A and the load on port J10 (C) has been detected.
FRU List: BPD2A-PORT-10-C 1401241A A communication fault between the BPD 3A and the load on port J01 (A) has been detected.
FRU List: BPD3A-PORT-01-A 1401242A A communication fault between the BPD 3A and the load on port J02 (A) has been detected.
FRU List: BPD3A-PORT-02-A 1401243A A communication fault between the BPD 3A and the load on port J03 (A) has been detected.
FRU List: BPD3A-PORT-03-A 1401244A A communication fault between the BPD 3A and the load on port J04 (A) has been detected.
FRU List: P9_CEC_DCA-02 14012A01 FRU List: BPC-B CBL-NET-BPCA-BPCB A communication fault between (BPA-A) BPC and (BPA-B) BPC.
BPC-A
43
14012A02 14012A10
14012A02 A communication fault between the BPC (BPA-A) and BPD 1A has been detected. BPE-BOARD-A 14012A08 FRU List: BPR-4A BPC-A BPE-BOARD-A BPE-BOARD-A 14012A03 A communication fault between the BPC (BPA-A) and BPD 2A has been detected. 14012A09 FRU List: BPR-5A BPC-A BPE-BOARD-A 14012A0A FRU List: BPR-6A BPC-A BPC-A BPE-BOARD-A BPE-BOARD-A 14012A0B 14012A05 FRU List: BPR-1A BPC-A BPE-BOARD-A BPE-BOARD-A 14012A10 14012A06 FRU List: BPR-2A BPC-A BPC-A BPE-BOARD-A BPD-2A 14012A07 FRU List: BPR-3A BPC-A Communication error btween BPC A and BPR 3A. BPR-2A BPR-3A BPE-BOARD-A Communication error btween BPC A and BPR 2A. FRU List: BPR-1A BPD-1A BPA-A has reported an over-current on the 350VDC bulk. Communication error btween BPC A and BPR 1A. FRU List: BPH-A BPC-A Communication error btween BPC A and BPH A. Communication error btween BPC A and BPR 6A. Communication error btween BPC A and BPR 5A. Communication error btween BPC A and BPR 4A.
FRU List: BPD-2A BPC-A BPE-BOARD-A 14012A04 A communication fault between the BPC (BPA-A) and BPD 3A has been detected.
44
14012A11 14012A16
14012A11 FRU List: BPR-1A BPD-1A BPC-A BPD-2A BPR-2A BPR-3A BPE-BOARD-A 14012A12 FRU List: BPR-2A BPD-1A BPC-A BPD-2A BPR-1A BPR-3A BPE-BOARD-A 14012A13 FRU List: BPR-3A BPD-1A BPC-A BPD-2A BPR-1A BPR-2A BPE-BOARD-A BPR-3A has reported an over-current on the 350VDC bulk. BPR-2A has reported an over-current on the 350VDC bulk. BPR-1A has reported an over-current on the 350VDC bulk. 14012A14 FRU List: BPR-4A BPD-1A BPC-A BPD-2A BPR-5A BPR-6A BPE-BOARD-A 14012A15 FRU List: BPR-5A BPD-1A BPC-A BPD-2A BPR-4A BPR-6A BPE-BOARD-A 14012A16 FRU List: BPR-6A BPD-1A BPC-A BPD-2A BPR-4A BPR-5A BPE-BOARD-A BPR-6A has reported an over-current on the 350VDC bulk. BPR-5A has reported an over-current on the 350VDC bulk. BPR-4A has reported an over-current on the 350VDC bulk.
45
14012A20 14012A33
14012A20 A BPA has reported No airflow in cage. Make sure that there are no blocked or dirty air inlet or filters. Verify that all unused logic positions are filled with filler books and that the BPF on the A-side has a cover over it / BPF on B-side does not. BPR-1A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM. 14012A26 BPR-6A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
FRU List: BPR-6A 14012A31 BPA-A side detects that IBF-1A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-1A)
14012A21
FRU List: BPR-1A 14012A22 BPR-2A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
FRU List: IBF-1A BPR-1A BPC-A BPE-BOARD-A 14012A32 BPA-A side detects that IBF-2A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-2A)
FRU List: BPR-2A 14012A23 BPR-3A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
FRU List: BPR-3A 14012A24 BPR-4A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
BPE-BOARD-A 14012A33 BPA-A side detects that IBF-3A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-3A)
FRU List: BPR-4A 14012A25 BPR-5A located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
46
14012A34 14012A52
14012A34 BPA-A side detects that IBF-4A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-4A)a 14012A43 BPA-A side detects that IBF-3A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-3A)
FRU List: IBF-4A BPR-4A BPC-A BPE-BOARD-A 14012A35 BPA-A side detects that IBF-5A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-5A)
FRU List: IBF-3A 14012A44 BPA-A side detects that IBF-4A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-4A)
FRU List: IBF-4A 14012A45 BPA-A side detects that IBF-5A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-5A)
FRU List: IBF-5A BPR-5A BPC-A BPE-BOARD-A 14012A36 BPA-A side detects that IBF-6A has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-6A)
FRU List: IBF-5A 14012A46 BPA-A side detects that IBF-6A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-6A)
FRU List: IBF-6A 14012A51 BPC-A side detects that IBF-1A is disconnected. (IBF is connected to BPA-A BPR-1A)
FRU List: IBF-6A BPR-6A BPC-A BPE-BOARD-A 14012A41 BPA-A side detects that IBF-1A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-1A)
FRU List: BPR-1A IBF-1A CBL-IBF1A BPC-A BPE-BOARD-A 14012A52 BPC-A side detects that IBF-2A is disconnected. (IBF is connected to BPA-A BPR-2A)
FRU List: IBF-1A 14012A42 BPA-A side detects that IBF-2A has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-A BPR-2A)
47
14012A53 14012B04
BPE-BOARD-A 14012A53 BPC-A side detects that IBF-2A is disconnected. (IBF is connected to BPA-A BPR-2A) BPE-BOARD-A 14012A85 The B-side BPC has detected that the cross feed from the A-side has failed.
CBL-IBF3A BPD-2A BPC-A BPR-1A BPE-BOARD-A BPR-2A 14012A54 BPC-A side detects that IBF-4A is disconnected. (IBF is connected to BPA-A BPR-4A) BPE-BOARD-A 14012B01 FRU List: BPC-A CBL-NET-BPCA-BPCB BPC-B 14012B02 A communication fault between the BPC (BPA-B) and BPD 1B has been detected. A communication fault between (BPA-B) BPC and (BPA-A) BPC.
FRU List: BPR-4A IBF-4A CBL-IBF4A BPC-A BPE-BOARD-A 14012A55 BPC-A side detects that IBF-5A is disconnected. (IBF is connected to BPA-A BPR-5A)
FRU List: BPD-1B BPC-B BPE-BOARD-B 14012B03 A communication fault between the BPC (BPA-B) and BPD 2B has been detected.
FRU List: BPR-5A IBF-5A CBL-IBF5A BPC-A BPE-BOARD-A 14012A56 BPC-A side detects that IBF-6A is disconnected. (IBF is connected to BPA-A BPR-6A)
FRU List: BPD-2B BPC-B BPE-BOARD-B 14012B04 A communication fault between the BPC (BPA-B) and BPD 3B has been detected.
48
14012B05 14012B12
BPC-B BPE-BOARD-B 14012B05 FRU List: BPR-1B BPC-B BPE-BOARD-B 14012B06 FRU List: BPR-2B BPC-B BPE-BOARD-B 14012B07 FRU List: BPR-3B BPC-B BPE-BOARD-B 14012B08 FRU List: BPR-4B BPC-B BPE-BOARD-B 14012B09 FRU List: BPR-5B BPC-B BPE-BOARD-B 14012B0A FRU List: BPR-6B Communication error btween BPC B and BPR 6B. FRU List: BPR-2B BPD-1B BPC-B
Chapter 2. 1xxx Reference Codes
BPC-B BPE-BOARD-B 14012B0B FRU List: BPH-B BPC-B BPE-BOARD-B 14012B10 FRU List: BPR-1A BPD-1A BPC-A BPD-2A BPR-2A BPR-3A BPE-BOARD-A 14012B11 FRU List: BPR-1B BPD-1B BPC-B BPD-2B BPR-2B BPR-3B BPE-BOARD-B 14012B12 BPR-2B has reported an over-current on the 350VDC bulk. BPR-1B has reported an over-current on the 350VDC bulk. BPA-A has reported an over-current on the 350VDC bulk. Communication error btween BPC B and BPH B.
49
14012B13 14012B23
BPD-2B BPR-1B BPR-3B BPE-BOARD-B 14012B13 FRU List: BPR-3B BPD-1B BPC-B BPD-2B BPR-1B BPR-2B BPE-BOARD-B 14012B14 FRU List: BPR-4B BPD-1B BPC-B BPD-2B BPR-5B BPR-6B BPE-BOARD-B 14012B15 FRU List: BPR-5B BPD-1B BPC-B BPD-2B BPR-4B BPR-6B FRU List: BPR-3B BPR-5B has reported an over-current on the 350VDC bulk. FRU List: BPR-2B 14012B23 BPR-3B located in BPA-B has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM. FRU List: BPR-1B 14012B22 BPR-2B located in BPA-B has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM. BPR-4A has reported an over-current on the 350VDC bulk. 14012B21 BPR-3B has reported an over-current on the 350VDC bulk. FRU List: BPR-6B BPD-1B BPC-B BPD-2B BPR-4B BPR-5B BPE-BOARD-B 14012B20 A BPA has reported No airflow in cage. Make sure that there are no blocked or dirty air inlet or filters. Verify that all unused logic positions are filled with filler books and that the BPF on the A-side has a cover over it / BPF on B-side does not. BPR-1B located in BPA-B has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM. BPE-BOARD-B 14012B16 BPR-6B has reported an over-current on the 350VDC bulk.
50
14012B24 14012B36
14012B24 BPR-4B located in BPA-B has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM. 14012B33 BPA-B side detects that IBF-3B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-B BPR-3B)
FRU List: BPR-4B 14012B25 BPR-5B located in BPA-B has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
FRU List: IBF-3B BPR-3B BPC-B BPE-BOARD-B 14012B34 BPA-A side detects that IBF-4B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-A BPR-4A)
FRU List: BPR-5B 14012B26 BPR-6B located in BPA-A has reported an Over Temperature. Make sure that the Air inlets are not blocked / filler books installed in empty locations and no heat source is located near the BPR ASM.
FRU List: BPR-6B 14012B31 BPA-B side detects that IBF-1B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-B BPR-1B)
14012B35
BPA-B side detects that IBF-5B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-B BPR-5B)
FRU List: IBF-1B BPR-1B BPC-B BPE-BOARD-B 14012B32 BPA-B side detects that IBF-2B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-B BPR-2B)
FRU List: IBF-5B BPR-5B BPC-B BPE-BOARD-B 14012B36 BPA-B side detects that IBF-6B has dropped below a usable level. The system may power off soon. The IBF will be charged after power is restored. (IBF is connected to BPA-B BPR-6B)
51
14012B41 14012B55
14012B41 BPA-B side detects that IBF-1B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-1B) BPE-BOARD-B 14012B52 BPC-B side detects that IBF-2B is disconnected. (IBF is connected to BPA-B BPR-2B)
FRU List: IBF-1B 14012B42 BPA-B side detects that IBF-2B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-2B)
FRU List: IBF-2B 14012B43 BPA-B side detects that IBF-3B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-3B)
14012B53
BPC-B side detects that IBF-3B is disconnected. (IBF is connected to BPA-B BPR-3B)
FRU List: IBF-3B 14012B44 BPA-B side detects that IBF-4B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-4B)
FRU List: BPR-3B IBF-3B CBL-IBF3B BPC-B BPE-BOARD-B BPA-B side detects that IBF-5B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-5B) 14012B54 BPC-B side detects that IBF-4B is disconnected. (IBF is connected to BPA-B BPR-4B)
FRU List: IBF-5B 14012B46 BPA-B side detects that IBF-5B has been charged to normal capcity. The IBF is available to again to provide power. (IBF is connected to BPA-B BPR-5B)
FRU List: BPR-4B IBF-4B CBL-IBF4B BPC-B BPE-BOARD-B BPC-B side detects that IBF-1B is disconnected. (IBF is connected to BPA-B BPR-1B) 14012B55 BPC-B side detects that IBF-5B is disconnected. (IBF is connected to BPA-B BPR-5B)
52
14012B56 1401322A
BPE-BOARD-B 14012B56 BPC-B side detects that IBF-6B is disconnected. (IBF is connected to BPA-B BPR-6B) 1401318A 14013097 BPC A side detects cabling order to a MDA different than to the other MDAs. (This BPA sides view). Check and correct cable plugging. A communication fault between BPC B and the load on port J08 (A) has been detected.
FRU List: BPR-6B IBF-6B CBL-IBF6B BPC-B BPE-BOARD-B 14012B85 The A-side BPC has detected that the cross feed from the B-side has failed. DCA number one is defective.
FRU List: BPCB-PORT-08-A 1401319A A communication fault between BPC B and the load on port J09 (A) has been detected.
FRU List: BPCB-PORT-09-A 140131AB A communication fault between BPC B and the load on port J10 (B) has been detected.
FRU List: BPCB-PORT-10-B BPC A side has detected unmatched FRUs in the same CageID. Check P/Ns and codelevel of the Power FRUs in the cage. BPC A side has detected miscabling to DCA port. Correct cabling error. BPC A side detects cabling order to a DCA different than to the other DCAs. (This BPA sides view). Check and correct cable plugging. BPC A side detects cabling order to a MDA different than to the other MDAs. (This BPA sides view). Check and correct cable plugging. BPC B side has detected unmatched FRUs in the same Cage ID. Check P/Ns and code level of the Power FRUs in the cage. BPC B side has detected miscabling to DCA port. Correct cabling error. BPC B side detects cabling order to a DCA different than to the other DCAs. (This BPA sides view). Check and correct cable plugging. 140131AC A communication fault between BPC B and the load on port J10 (C) has been detected.
14013005
FRU List: BPCB-PORT-10-C 140131BB A communication fault between BPC B and the load on port J11 (B) has been detected.
14013006
FRU List: BPCB-PORT-11-B 140131BC A communication fault between BPC B and the load on port J11 (C) has been detected.
14013007
14013090
FRU List: BPCB-PORT-11-C 1401321A A communication fault between the BPD 1B and the load on port J01 has been detected (A).
14013095
FRU List: BPD1B-PORT-01-A 1401322A A communication fault between the BPD 1B and the load on port J02 has been detected (A).
14013096
53
1401323A 140132AC
1401323A A communication fault between the BPD 1B and the load on port J03 has been detected (A). 1401328B A communication fault between the BPD 1B and the load on port J08 (B) has been detected.
FRU List: BPD1B-PORT-03-A 1401324A A communication fault between the BPD 1B and the load on port J04 has been detected (A).
FRU List: BPD1B-PORT-08-B 1401328C A communication fault between the BPD 1B and the load on port J08 (C) has been detected.
FRU List: BPD1B-PORT-04-A 1401325A A communication fault between the BPD 1B and the load on port J05 (A) has been detected.
FRU List: BPD1B-PORT-08-C 1401329A A communication fault between the BPD 1B and the load on port J09 (A) has been detected.
FRU List: BPD1B-PORT-05-A 1401326A A communication fault between the BPD 1B and the load on port J06 (A) has been detected.
FRU List: BPD1B-PORT-09-A 1401329B A communication fault between the BPD 1B and the load on port J09 (B) has been detected.
FRU List: BPD1B-PORT-06-A 1401327A A communication fault between the BPD 1B and the load on port J07 (A) has been detected.
FRU List: BPD1B-PORT-09-B 1401329C A communication fault between the BPD 1B and the load on port J09 (C) has been detected.
FRU List: BPD1B-PORT-07-A 1401327B A communication fault between the BPD 1B and the load on port J07 (B) has been detected.
FRU List: BPD1B-PORT-09-C 140132AA A communication fault between the BPD 1B and the load on port J10 (A) has been detected.
FRU List: BPD1B-PORT-07-B 1401327C A communication fault between the BPD 1B and the load on port J07 (C) has been detected.
FRU List: BPD1B-PORT-10-A 140132AB A communication fault between the BPD 1B and the load on port J10 (B) has been detected.
FRU List: BPD1B-PORT-07-C 1401328A A communication fault between the BPD 1B and the load on port J08 (A) has been detected.
FRU List: BPD1B-PORT-10-B 140132AC A communication fault between the BPD 1B and the load on port J10 (C) has been detected.
54
1401331A 140133AB
1401331A A communication fault between the BPD 2B and the load on port J01 (A) has been detected. 1401337C A communication fault between the BPD 2B and the load on port J07 (C) has been detected.
FRU List: BPD2B-PORT-01-A 1401332A A communication fault between the BPD 2B and the load on port J02 (A) has been detected.
FRU List: BPD2B-PORT-07-C 1401338A A communication fault between the BPD 2B and the load on port J08 (A) has been detected.
FRU List: BPD2B-PORT-02-A 1401333A A communication fault between the BPD 2B and the load on port J03 (A) has been detected.
FRU List: BPD2B-PORT-08-A 1401338B A communication fault between the BPD 2B and the load on port J08 (B) has been detected.
FRU List: BPD2B-PORT-03-A 1401334a A communication fault between the BPD 2B and the load on port J04 (A) has been detected.
FRU List: BPD2B-PORT-08-B 1401338C A communication fault between the BPD 2B and the load on port J08 (C) has been detected.
FRU List: BPD2B-PORT-04-A 1401335A A communication fault between the BPD 2B and the load on port J05 (A) has been detected.
FRU List: BPD2B-PORT-08-C 1401339B A communication fault between the BPD 2B and the load on port J09 (B) has been detected.
FRU List: BPD2B-PORT-05-A 1401336A A communication fault between the BPD 2B and the load on port J06 (A) has been detected.
FRU List: BPD2B-PORT-09-B 1401339C A communication fault between the BPD 2B and the load on port J09 (C) has been detected.
FRU List: BPD2B-PORT-06-A 1401337A A communication fault between the BPD 2B and the load on port J07 (A) has been detected.
FRU List: BPD2B-PORT-09-C 140133AA A communication fault between the BPD 2B and the load on port J10 (A) has been detected.
FRU List: BPD2B-PORT-07-A 1401337B A communication fault between the BPD 2B and the load on port J07 (B) has been detected.
FRU List: BPD2B-PORT-10-A 140133AB A communication fault between the BPD 2B and the load on port J10 (B) has been detected.
55
140133AC 140151BC
140133AC A communication fault between the BPD 2B and the load on port J10 (C) has been detected. 14014006 FRU List: NEXTLVL 14014007 1401341A A communication fault between the BPD 3B and the load on port J01 (A) has been detected. A power redundancy command was run, which produced this log entry. This does not indicate a failure. The error log entry contains information that product engineering will use to investigate FRU redundancy problems. The firmware level on BPC A does not match the firmware level on BPC B.
FRU List: BPD3B-PORT-01-A 1401342A A communication fault between the BPD 3B and the load on port J02 (A) has been detected.
Servicer Response: Informational only; no action is required. 1401518A An over current has been detected on 350V between BPC A and the load on its port J08 (A).
FRU List: BPD3B-PORT-02-A 1401343A A communication fault between the BPD 3B and the load on port J03 (A) has been detected.
FRU List: BPCA-PORT-08-A 1401519A An over current has been detected on 350V between BPC A and the load on its port J09 (A).
FRU List: BPD3B-PORT-03-A 1401344A A communication fault between the BPD 3B and the load on port J04 (A) has been detected.
FRU List: BPCA-PORT-09-A 140151AB An over current has been detected on 350V between BPC A and the load on its port J10 (B).
FRU List: BPD3B-PORT-04-A 14014001 The Auto-Code-Download (ACDL) of the power subsystem encountered an error. Contact next level of support for assistance. The frame MTMS was not resolved by HMC. Contact next level of support for assistance. The BPC has found duplicate Mailbox IP addresses on Network A. Contact next level of support for assistance. The BPC has found duplicate Mailbox IP addresses on Network B. Contact next level of support for assistance. A DHCP address was not assigned on Network A. Contact next level of support for assistance.
FRU List: BPCA-PORT-10-B 140151AC An over current has been detected on 350V between BPC A and the load on its port J10 C.
14014002
FRU List: BPCA-PORT-10-C 140151BB An over current has been detected on 350V between BPC A and the load on its port J11 (B).
14014003
FRU List: BPCA-PORT-11-B 140151BC An over current has been detected on 350V between BPC A and the load on its port J11 (C).
14014004
14014005
56
1401521A 140152AA
1401521A An over current has been detected on 350V between BPD 1A and the load on its port J01 (A). 1401527C An over current has been detected on 350V between BPD 1A and the load on its port J07 (C).
FRU List: BPD1A-PORT-01-A 1401522A An over current has been detected on 350V between BPD 1A and the load on its port J02 (A).
FRU List: BPD1A-PORT-07-C 1401528A An over current has been detected on 350V between BPD 1A and the load on its port J08 (A).
FRU List: BPD1A-PORT-02-A 1401523A An over current has been detected on 350V between BPD 1A and the load on its port J03 (A).
FRU List: BPD1A-PORT-08-A 1401528B An over current has been detected on 350V between BPD 1A and the load on its port J08 (B).
FRU List: BPD1A-PORT-03-A 1401524A An over current has been detected on 350V between BPD 1A and the load on its port J04 (A).
FRU List: BPD1A-PORT-08-B 1401528C An over current has been detected on 350V between BPD 1A and the load on its port J08 (C).
FRU List: BPD1A-PORT-04-A 1401525A An over current has been detected on 350V between BPD 1A and the load on its port J05 (A).
FRU List: BPD1A-PORT-08-C 1401529A An over current has been detected on 350V between BPD 1A and the load on its port J09 (A).
FRU List: BPD1A-PORT-05-A 1401526A An over current has been detected on 350V between BPD 1A and the load on its port J06 (A).
FRU List: BPD1A-PORT-09-A 1401529B An over current has been detected on 350V between BPD 1A and the load on its port J09 (B).
FRU List: BPD1A-PORT-06-A 1401527A An over current has been detected on 350V between BPD 1A and the load on its port J07 (A).
FRU List: BPD1A-PORT-09-B 1401529C An over current has been detected on 350V between BPD 1A and the load on its port J09 (C).
FRU List: BPD1A-PORT-07-A 1401527B An over current has been detected on 350V between BPD 1A and the load on its port J07 (B).
FRU List: BPD1A-PORT-09-C 140152AA An over current has been detected on 350V between BPD 1A and the load on its port J10 (A).
57
140152AB 1401539B
140152AB An over current has been detected on 350V between BPD 1A and the load on its port J10 (B). 1401537A An over current has been detected on 350V between BPD 2A and the load on its port J07 (A).
FRU List: BPD1A-PORT-10-B 140152AC An over current has been detected on 350V between BPD 1A and the load on its port J10 (C).
FRU List: BPD2A-PORT-07-A 1401537B An over current has been detected on 350V between BPD 2A and the load on its port J07 (B).
FRU List: BPD1A-PORT-10-C 1401531A An over current has been detected on 350V between BPD 2A and the load on its port J01 (A).
FRU List: BPD2A-PORT-07-B 1401537C An over current has been detected on 350V between BPD 2A and the load on its port J07 (C).
FRU List: BPD2A-PORT-01-A 1401532A An over current has been detected on 350V between BPD 2A and the load on its port J02 (A).
FRU List: BPD2A-PORT-07-C 1401538A An over current has been detected on 350V between BPD 2A and the load on its port J08 (A).
FRU List: BPD2A-PORT-02-A 1401533A An over current has been detected on 350V between BPD 2A and the load on its port J03 (A).
FRU List: BPD2A-PORT-08-A 1401538B An over current has been detected on 350V between BPD 2A and the load on its port J08 (B).
FRU List: BPD2A-PORT-03-A 1401534A An over current has been detected on 350V between BPD 2A and the load on its port J04 (A).
FRU List: BPD2A-PORT-08-B 1401538C An over current has been detected on 350V between BPD 2A and the load on its port J08 (C).
FRU List: BPD2A-PORT-04-A 1401535A An over current has been detected on 350V between BPD 2A and the load on its port J05 (A).
FRU List: BPD2A-PORT-08-C 1401539A An over current has been detected on 350V between BPD 2A and the load on its port J09 (A).
FRU List: BPD2A-PORT-05-A 1401536A An over current has been detected on 350V between BPD 2A and the load on its port J06 (A).
FRU List: BPD2A-PORT-09-A 1401539B An over current has been detected on 350V between BPD 2A and the load on its port J09 (B).
58
1401539C 1401622A
1401539C An over current has been detected on 350V between BPD 2A and the load on its port J09 (C). 1401618A An over current has been detected on 350V between BPC B and the load on its port J08 (A).
FRU List: BPD2A-PORT-09-C 140153AA An over current has been detected on 350V between BPD 2A and the load on its port J10 (A).
FRU List: BPCB-PORT-08-A 1401619A An over current has been detected on 350V between BPC B and the load on its port J09 (A).
FRU List: BPD2A-PORT-10-A 140153AB An over current has been detected on 350V between BPD 2A and the load on its port J10 (B).
FRU List: BPCB-PORT-09-A 140161AB An over current has been detected on 350V between BPC B and the load on its port J10 (B).
FRU List: BPD2A-PORT-10-B 140153AC An over current has been detected on 350V between BPD 2A and the load on its port J10 (C).
FRU List: BPCB-PORT-10-B 140161AC An over current has been detected on 350V between BPC B and the load on its port J10 (C).
FRU List: BPD2A-PORT-10-C 1401541A An over current has been detected on 350V between BPD 3A and the load on its port J01 (A).
FRU List: BPCB-PORT-10-B 140161BB An over current has been detected on 350V between BPC B and the load on its port J11 (B).
FRU List: BPD3A-PORT-01-A 1401542A An over current has been detected on 350V between BPD 3A and the load on its port J02 (A).
FRU List: BPCB-PORT-11-B 140161BC An over current has been detected on 350V between BPC B and the load on its port J11 (C).
FRU List: BPD3A-PORT-02-A 1401543A An over current has been detected on 350V between BPD 3A and the load on its port J03 (A).
FRU List: BPCB-PORT-11-C 1401621A An over current has been detected on 350V between BPD 1B and the load on its port J01 (A).
FRU List: BPD3A-PORT-03-A 1401544A An over current has been detected on 350V between BPD 2A and the load on its port J04 (A).
FRU List: BPD1B-PORT-01-A 1401622A An over current has been detected on 350V between BPD 1B and the load on its port J02 (A).
59
1401623A 140162AC
1401623A An over current has been detected on 350V between BPD 1B and the load on its port J03 (A). 1401628B An over current has been detected on 350V between BPD 1B and the load on its port J08 (B).
FRU List: BPD1B-PORT-03-A 1401624A An over current has been detected on 350V between BPD 1B and the load on its port J04 (A).
FRU List: BPD1B-PORT-08-B 1401628C An over current has been detected on 350V between BPD 1B and the load on its port J08 (C).
FRU List: BPD1B-PORT-04-A 1401625A An over current has been detected on 350V between BPD 1B and the load on its port J05 (A).
FRU List: BPD1B-PORT-08-C 1401629A An over current has been detected on 350V between BPD 1B and the load on its port J09 (A).
FRU List: BPD1B-PORT-05-A 1401626A An over current has been detected on 350V between BPD 1B and the load on its port J06 (A).
FRU List: BPD1B-PORT-09-A 1401629B An over current has been detected on 350V between BPD 1B and the load on its port J09 (B).
FRU List: BPD1B-PORT-06-A 1401627A An over current has been detected on 350V between BPD 1B and the load on its port J07 (A).
FRU List: BPD1B-PORT-09-B 1401629C An over current has been detected on 350V between BPD 1B and the load on its port J09 (C).
FRU List: BPD1B-PORT-07-A 1401627B An over current has been detected on 350V between BPD 1B and the load on its port J07 (B).
FRU List: BPD1B-PORT-09-C 140162AA An over current has been detected on 350V between BPD 1B and the load on its port J10 (A).
FRU List: BPD1B-PORT-07-B 1401627C An over current has been detected on 350V between BPD 1B and the load on its port J07 (C).
FRU List: BPD1B-PORT-10-A 140162AB An over current has been detected on 350V between BPD 1B and the load on its port J10 (B).
FRU List: BPD1B-PORT-07-C 1401628A An over current has been detected on 350V between BPD 1B and the load on its port J08 (A).
FRU List: BPD1B-PORT-10-B 140162AC An over current has been detected on 350V between BPD 1B and the load on its port J10 (C).
60
1401631A 140163AA
1401631A An over current has been detected on 350V between BPD 2B and the load on its port J01 (A). 1401637C An over current has been detected on 350V between BPD 2B and the load on its port J07 (C).
FRU List: BPD2B-PORT-01-A 1401632A An over current has been detected on 350V between BPD 2B and the load on its port J02 (A).
FRU List: BPD2B-PORT-07-C 1401638A An over current has been detected on 350V between BPD 2B and the load on its port J08 (A).
FRU List: BPD2B-PORT-02-A 1401633A An over current has been detected on 350V between BPD 2B and the load on its port J03 (A).
FRU List: BPD2B-PORT-08-A 1401638B An over current has been detected on 350V between BPD 2B and the load on its port J07 (B).
FRU List: BPD2B-PORT-03-A 1401634A An over current has been detected on 350V between BPD 2B and the load on its port J04 (A).
FRU List: BPD2B-PORT-08-B 1401638C An over current has been detected on 350V between BPD 2B and the load on its port J07 (C).
FRU List: BPD2B-PORT-04-A 1401635A An over current has been detected on 350V between BPD 2B and the load on its port J05 (A).
FRU List: BPD2B-PORT-08-C 1401639A An over current has been detected on 350V between BPD 2B and the load on its port J09 (A).
FRU List: BPD2B-PORT-05-A 1401636A An over current has been detected on 350V between BPD 2B and the load on its port J06 (A).
FRU List: BPD2B-PORT-09-A 1401639B An over current has been detected on 350V between BPD 2B and the load on its port J09 (B).
FRU List: BPD2B-PORT-06-A 1401637A An over current has been detected on 350V between BPD 2B and the load on its port J07 (A).
FRU List: BPD2B-PORT-09-B 1401639C An over current has been detected on 350V between BPD 2B and the load on its port J07 (C).
FRU List: BPD2B-PORT-07-A 1401637B An over current has been detected on 350V between BPD 2B and the load on its port J07 (B).
FRU List: BPD2B-PORT-09-C 140163AA An over current has been detected on 350V between BPD 2B and the load on its port J10 (A).
61
140163AB 14017098
140163AB An over current has been detected on 350V between BPD 2B and the load on its port J07 (B). 14017094 FRU List: BPD-3A BPC-A 14017095 FRU List: BPR-1A BPC-A BPD-1A BPD-2A IBF-1A BPE-BOARD-A 1401642A An over current has been detected on 350V between BPD 3B and the load on its port J02 (A). 14017096 FRU List: BPR-2A BPC-A 1401643A An over current has been detected on 350V between BPD 3B and the load on its port J03 (A). BPD-1A BPD-2A IBF-2A BPE-BOARD-A 14017097 FRU List: BPR-3A BPC-A BPD-1A BPD-1 is defective in BPA-A. BPD-2A IBF-3A BPE-BOARD-A BPC-A 14017098 14017093 FRU List: BPD-2A BPC-A BPD-2 is defective in BPA-A. FRU List: BPR-4A BPC-A BPA-A BPR-4 is defective. BPA-A BPR-3 is defective. BPA-A BPR-2 is defective. BPA-A BPR-1 is defective. BPD-3 is defective in BPA-A.
FRU List: BPD2B-PORT-10-B 140163AC An over current has been detected on 350V between BPD 2B and the load on its port J10 (C).
FRU List: BPD2B-PORT-10-C 1401641A An over current has been detected on 350V between BPD 3B and the load on its port J01 (A).
FRU List: BPD3B-PORT-03-A 1401644A An over current has been detected on 350V between BPD 3B and the load on its port J04 (A).
FRU List: BPD3B-PORT-04-A 14017091 FRU List: BPC-A 14017092 FRU List: BPD-1A The BPC in BPA-A is defective.
62
14017099 140170A5
BPD-1A BPD-2A IBF-3A BPE-BOARD-A 14017099 FRU List: BPR-5A BPC-A BPD-1A BPD-2A IBF-3A BPE-BOARD-A 1401709A FRU List: BPR-5A BPC-A BPD-1A BPD-2A IBF-3A BPE-BOARD-A 1401709B FRU List: BPH-A BPC-A 140170A1 BPC-A side detects that IBF-1A is defective. (IBF is connected to BPA-A BPR-1A) BPA-A BPH is defective. FRU List: IBF-4A BPR-4A CBL-IBF4A BPC-A BPE-BOARD-A 140170A5 BPC-A side detects that IBF-5A is defective. (IBF is connected to BPA-A BPR-5A) BPA-A BPR-6 is defective. FRU List: IBF-3A BPR-3A CBL-IBF3A BPC-A BPE-BOARD-A 140170A4 BPC-A side detects that IBF-4A is defective. (IBF is connected to BPA-A BPR-4A) BPA-A BPR-5 is defective. FRU List: IBF-2A BPR-2A CBL-IBF2A BPC-A BPE-BOARD-A 140170A3 BPC-A side detects that IBF-3A is defective. (IBF is connected to BPA-A BPR-3A) 140170A2 BPC-A side detects that IBF-2A is defective. (IBF is connected to BPA-A BPR-2A)
63
140170A6 14017199
140170A6 BPC-A side detects that IBF-6A is defective. (IBF is connected to BPA-A BPR-6A) 14017196 FRU List: BPR-2B BPC-B BPD-1B BPD-2B IBF-2B BPE-BOARD-B 14017197 FRU List: BPR-3B BPD-1 is defective in BPA-B. BPC-B BPD-1B BPD-2B IBF-3B 14017193 FRU List: BPD-2B BPC-B 14017194 FRU List: BPD-3B BPC-B 14017195 FRU List: BPR-1B BPC-B BPD-1B BPD-2B IBF-1B BPE-BOARD-B BPA-A BPR-1 is defective. BPD-3 is defective in BPA-B. BPD-2 is defective in BPA-B. BPE-BOARD-B 14017198 FRU List: BPR-4B BPC-B BPD-1B BPD-2B IBF-3B BPE-BOARD-B 14017199 FRU List: BPR-5B BPC-B BPD-1B BPD-2B IBF-3B BPE-BOARD-B BPA-B BPR-5 is defective. BPA-B BPR-4 is defective. BPA-B BPR-3 is defective. BPA-B BPR-2 is defective.
FRU List: IBF-6A BPR-6A CBL-IBF6A BPC-A BPE-BOARD-A 14017191 FRU List: BPC-B 14017192 FRU List: BPD-1B BPC-B The BPC in BPA-B is defective.
64
1401719A 140171A6
1401719A FRU List: BPR-5B BPC-B BPE-BOARD-B BPD-1B BPD-2B IBF-3B BPE-BOARD-B 1401719B FRU List: BPH-B BPC-B BPE-BOARD-B 140171A1 BPC-B side detects that IBF-1B is defective. (IBF is connected to BPA-B BPR-1B) 140171A5 BPC-B side detects that IBF-5B is defective. (IBF is connected to BPA-B BPR-5B) BPA-B BPH is defective. FRU List: IBF-4B BPR-4B CBL-IBF4B BPC-B 140171A4 BPC-B side detects that IBF-4B is defective. (IBF is connected to BPA-B BPR-4B) BPA-B BPR-6 is defective. BPR-3B CBL-IBF3B BPC-B
CBL-IBF1B CBL-IBF5B BPC-B BPC-B BPE-BOARD-B BPE-BOARD-B 140171A2 BPC-B side detects that IBF-2B is defective. (IBF is connected to BPA-B BPR-2B) 140171A6 BPC-B side detects that IBF-6B is defective. (IBF is connected to BPA-B BPR-6B)
CBL-IBF2B CBL-IBF6B BPC-B BPC-B BPE-BOARD-B BPE-BOARD-B 140171A3 BPC-B side detects that IBF-3B is defective. (IBF is connected to BPA-B BPR-3B)
65
14018072 17503020
14018072 BPA-A has reported a temperature warning in cage. Make sure that there are no blocked/dirty air inlet or filters. Verify that all unused logic positions are filled with filler books and that the BPF on the A-side has a cover over it / BPF on B-side does not. BPA-B has reported a temperature warning in cage. Make sure that there are no blocked/dirty air inlet or filters. Verify that all unused logic positions are filled with filler books and that the BPF on the A-side has a cover over it / BPF on B-side does not. A-side BPC detects that the room UEPO is in bypass. Verify the room UEPO loop is enabled. 14018133 FRU List: $NOBPAFRU 14018134 This contains an ACDL log Informational SRC. Informational message: An internal bulk power software error occurred. A TMS (60) was received Informational SRC.
14018073
14018135
Servicer Response: Informational only; no action is required. 14018136 A processor node has entered throttling mode.
140180C3
Servicer Response: Informational only; no action is required. 140181C3 B-side BPC detects that the room UEPO is in bypass. Verify the room UEPO loop is enabled.
FRU List: EPO-SWITCH BPC-A CBL-BPCA-EPO 14018130 CAGE P/T Fru recovery. Cage in power recovery mode for information only. The UEPO switch has been used. This is an informational SRC. A send secure vpd command was received. Informational SRC.
14018131
14018132
Servicer Response: If an MES is being installed, verify the configuration. FRU List: FCDEV FCIOA
66
17503029 1750FFFE
OPT_CLN 17503029 A device replacement has occurred 1750FFF3 FRU List: FCDEV 1750FFF4 FRU List: FCDEV 1750FFF5 FRU List: FCDEV 1750FFF6 Disk device detected recoverable error Disk sector read error Disk device problem Disk media format bad
Servicer Response: No action required. This reference code is logged for information only. 17503100 FRU List: FCINTF FCDEV FCIOA OPT_CLN 17503109 FRU List: FCDEV FCINTF FCIOA OPT_CLN 17503160 The volume in use is no longer accessible. IOP timed out a disk command Fibre Channel interface error occurred
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCDEV 1750FFFA Disk device wrong response was recovered by the IOP
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCDEV FCIOA OPT_CLN 1750FFFE Temporary Fibre Channel interface error
Servicer Response:: The storage subsystem configuration was changed, causing the volume in use to no longer be accessible. FRU List: FCDEV 17503161 The volume in use is no longer accessible.
Servicer Response:: The storage subsystem copy services functions have caused the volume in use to no longer be accessible. FRU List: FCDEV 175034FF Format in progress
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCINTF FCDEV
Servicer Response: The device indicated that a format is in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only.
FCIOA OPT_CLN
67
180A1511 180A7631
68
180A7634 180AFFF4
FRU List: DISKFAN 180A7634 FRU List: DISKFAN 180A8401 FRU List: DEVBPLN 180A8404 System log entry only, no service action required Device backplane problem Removable media power fault A fatal error occurred on fan 3
69
70
(20A8, 20Dx, 20EE, 20FF, 2102) Model 185 and A50 reference (error) codes
Model 185 and A50 reference (error) codes
20A80000 Insufficient information to boot. Servicer Response: Do thefollowing: 1. Verify that the bootp server is configured correctly for this client. 2. Check the network connections, then retry the operation. 20A80006 Boot image too large.
Servicer Response: Verifythat the network addresses on the server and gateway are correct. 20A80001 Client IP address is already in use by another networkdevice.
Servicer Response: Verify that the network addresses on the server andgateway are correct. 20A80002 Cannot get gateway IP address.
Servicer Response: Do the following: 1. Verify that the bootp server is configured correctly for this client. 2. Check the network connections, then retry the operation. 20D0000F Self-test failed on device. The error or location codeinformation may not be available.
Servicer Response: Verifythat the network addresses on the server and gateway are correct. 20A80003 Cannot get server hardware address.
Servicer Response: Verifythat the network addresses on the server and gateway are correct. 20A80004 Bootp failed.
Servicer Response: Do the following: 1. If a location code is specified, replace the device at that location. 2. Replace the system backplane. FRU List: SYSBKP2 20D00010 Selftest failed on device. Cannot locate package.
Servicer Response: Do the following: 1. Verify that the bootp server is configured correctly for this client. 2. Check the network connections, then retry the operation. 20A80005 File transmission (TFTP) failed.
71
20D00011 20D10005
1. If a location code is reported with the error, replace the device at that location code. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2 20D00011 RTAS attempt to allocate memory failed. 20D00902 The system is booting from the permanent (B) firmwareside.
Servicer Response: If the system was already booting from the permanent (B)side, this is an informational message. If it was not, it indicates that the system was unable to boot from the temporary (A) firmware side. Do the following: 1. Follow the operating system procedure to reject the firmware update. 2. Reinstall the latest system firmware. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D00903 The firmware was not able to find the /openprom package.
Servicer Response: Dothe following: 1. Check for system firmware updates, and apply if available. 2. Replace the system backplane. FRU List: SYSBKP2 20D008xx Failure to access VPD data.
Servicer Response:: Where xx is: xx Description ------------------0E, 0F Machine type or model 10, 11 System serial number 16, 17 Universal un FRU List: SYSBKP2 20D00900 Failed to generate universal unique ID (UUID) value.
Servicer Response: Dothe following: 1. Check for system firmware updates and apply if available. 2. Replace the system backplane. FRU List: SYSBKP2 20D10004 Failed to locate BMC device tree node.
Servicer Response: Dothe following: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D10005 Failed to reboot system.
Servicer Response: Dothe following: 1. Replace the memory DIMMs in the system. 2. Replace the system backplane. FRU List: SYSBKP2 20D00901 FRU List: SYSBKP2 Failed to communicate with the BMC. Replace the systembackplane.
Servicer Response: Do the following: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2
72
20D10006 20EE0011
20D10006 Failed to reboot system. 2. If the problem persists, contact your next level of support. FRU List: SYSBKP2 20EE000A Reserved
Servicer Response: Do the following: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D10007 Firmware error before stdout ready.
Servicer Response: Contact your next level of supportfor assistance. FRU List: NEXTLVL 20EE000B The system was not able to find an operating systemon the devices in the boot list.
Servicer Response: Do thefollowing: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D1000A Failed to send boot failed message to the BMC.
Servicer Response: Verify that the boot list containsat least one device with a valid operating system boot image. 20EE000F Unable to find the package node.
Servicer Response: Do thefollowing: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0010 Unable to run the root vpd method.
Servicer Response: Dothe following: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D10010 Stack underflow from fiber channel adapter.
Servicer Response: Do thefollowing: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0011 Unable to execute the vpd method.
Servicer Response: Dothe following: 1. Check for microcode updates for the fiber channel adapter, and apply if available. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20D10011 Failed to set the watchdog timer in the base motherboardcontroller.
Servicer Response: Do thefollowing: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2
Servicer Response: Do the following: 1. Check for system firmware updates, and apply if available.
73
20EE0012 20EE0101
20EE0012 Unable to execute the mem-dimm-vpd method. 20EE0021 The environment variable boot-device containedmore than seven entries.
Servicer Response: Dothe following: 1. Check for system firmware updates, and apply if available. 2. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0015 Failed to read VPD boot path field value.
Servicer Response: Do the following: 1. Verify that the boot list is correct. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0022 The environment variable boot-device containedan entry that exceeded 255 characters in length.
Servicer Response: Dothe following: 1. Verify that the boot list is correct. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0016 Failed to update VPD with the new boot pathfield value.
Servicer Response: Do the following: 1. Verify that the boot list is correct. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0100 Fcode resident on an I/O adapter is not supported onthis system. This error code only affects boot-time operation, not the functionality of the adapter under the operating system.
Servicer Response: Do the following: 1. Verify that the boot list is correct. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 20EE0020 The environment variable boot-device exceedsthe allowed character limit.
Servicer Response: Informational message.The Fcode driver of the adapter is not supported on this system. A compatible driver may be produced in the future, but does not guarantee one. Additional information may be available from your next level of support. 20EE0101 The baud rate specified for the com port is invalid.
Servicer Response: Do the following: 1. Verify that the boot list is correct. 2. Check for system firmware updates, and apply if available. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2
Servicer Response: Dothe following: 1. Use the System Management Services (SMS) menus to check the baud rate. Reset it to a valid value, if necessary. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2
74
20EE0102 21020010
20EE0102 An invalid number of data bits was specified for thecom port. 20EE0200 Installing an image to the permanent side is not allowed.
Servicer Response: Do the following: 1. Use the SMS menus to check the data bit setting. Reset it to a valid value, if necessary. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2 20EE0103 An invalid number of stop bits was specified for thecom port.
Servicer Response: Dothe following: 1. Boot from the temporary side. 2. Install the firmware. Note: If you are not able to boot from the temp side, perform the system firmware rejection function in the operating system, then attempt to install the latest firmware. 20EE0201 The format of the firmware installation image is notcorrect.
Servicer Response: do the following: 1. Use the SMS menus to check the stop bit setting. Reset it to a valid value, if necessary. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2 20EE0104 An invalid parity setting was specified for the comport.
Servicer Response: Install the firmware using a known good image. 20EE0210 Installing system firmware failed; the firmware may be corrupted.
Servicer Response:: Install the firmware using a known good image. Note: If the system firmware is corrupted, perform the system firmware rejection function, then attempt to install the firmware again. 20EE0220 Installing the system firmware failed; the firmware may be corrupted.
Servicer Response: Do the following: 1. Use the SMS menus to check the parity setting. Reset it to a valid value, if necessary. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2 20EE0105 An invalid handshake setting was specified for the comport.
Servicer Response:: Install the firmware using a known good image. Note: If the system firmware is corrupted, perform the system firmware rejection function, then attempt to install the firmware again. 20FF0001 Problem with VPD.
Servicer Response: Do the following: 1. Replace the part indicated by the location code. 2. If no location code is specified, replace the system backplane. FRU List: SYSBKP2 21020010 USB CD-ROM remained busy longer than the time allowed.
Servicer Response: Do the following: 1. Use the SMS menus to check the handshake setting. Reset it to a valid value, if necessary. 2. Check for system firmware updates, and apply if available. 3. Replace the system backplane. FRU List: SYSBKP2
Servicer Response: Dothe following: 1. Retry the operation. 2. Check for system firmware updates, and apply if available. 3. Replace the USB CD-ROM drive.
Chapter 3. 2xxx Reference Codes
75
21020011 21053020
4. Replace the system backplane. FRU List: SYSBKP2 21020011 USB CD-ROM: execution of ATA/ATAPI command was not completedwithin the time allowed. 21020013 USB CD-ROM: bootable CD is missing from the CD-ROM drive.
Servicer Response: Place a bootable CD-ROM in the USB CD-ROM drive. 21020014 USB CD-ROM: the CD in the drive has been changed.
Servicer Response: Do the following: 1. Retry the operation. 2. The CD in the USB CD-ROM drive may not be readable. Try another CD. 3. Replace the USB CD-ROM drive. 4. Replace the system backplane. FRU List: SYSBKP2 21020012 USB CD-ROM: execution of ATA/ATAPI command by the USBCD-ROM failed.
Servicer Response: Dothe following: 1. Retry the operation. 2. Check for system firmware updates, and apply if available. 3. Replace the USB CD-ROM drive. 4. Replace the system backplane. FRU List: SYSBKP2 21020015 USB CD-ROM: ATA/ATAPI packed command execution by USBCD-ROM failed.
Servicer Response: Do the following: 1. Check the power and signal connectors going to the USB CD-ROM drive, and correct any problems that you find. 2. Retry the operation. If the problem persists, continue with the next step. 3. The CD in the USB CD-ROM drive may not be readable. Try another CD. If the problem persists, continue with the next step. 4. Replace the USB CD-ROM drive. 5. Replace the system backplane. FRU List: SYSBKP2
Servicer Response: do the following: 1. The CD in the USB CD-ROM drive may not be readable. Try another CD. If the problem persists, continue with the next step. 2. Check for system firmware updates, and apply if available. 3. Replace the USB CD-ROM drive. 4. Replace the system backplane. FRU List: SYSBKP2
76
21053029 2105FFFE
FRU List: FCDEV FCIOA OPT_CLN 21053029 A device replacement has occurred The device indicated that a format is in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 2105FFF3 FRU List: FCDEV 2105FFF4 FRU List: FCDEV 2105FFF5 FRU List: FCDEV 2105FFF6 Disk device detected recoverable error Disk sector read error Disk device problem Disk media format bad
Servicer Response: No action required. This reference code is logged for information only. 21053100 FRU List: FCINTF FCDEV FCIOA OPT_CLN 21053109 FRU List: FCDEV FCINTF FCIOA OPT_CLN 21053160 The volume in use is no longer accessible. IOP timed out a disk command Fibre Channel interface error occurred
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCDEV 2105FFFA Disk device wrong response was recovered by the IOP
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCDEV FCIOA OPT_CLN 2105FFFE Temporary Fibre Channel interface error
Servicer Response:: The storage subsystem configuration was changed, causing the volume in use to no longer be accessible. FRU List: FCDEV 21053161 The volume in use is no longer accessible.
Servicer Response:: The storage subsystem copy services functions have caused the volume in use to no longer be accessible. FRU List: FCDEV 210534FF Format in progress
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCINTF FCDEV FCIOA OPT_CLN
Servicer Response:
77
21073002 2107FFFA
21073002 FRU List: FCPORT FCDEV FCIOA FCINTF OPT_CLN 21073010 FRU List: FCDEV FCIOA OPT_CLN 21073020 Storage subsystem configuration error Disk device returned wrong response to IOP Addressed device is not responding OPT_CLN 21073160 The volume in use is no longer accessible.
Servicer Response:: The storage subsystem configuration was changed, causing the volume in use to no longer be accessible. FRU List: FCDEV 21073161 The volume in use is no longer accessible.
Servicer Response:: The storage subsystem copy services functions have caused the volume in use to no longer be accessible. FRU List: FCDEV 210734FF Format in progress
Servicer Response: If an MES is being installed, verify the configuration. FRU List: FCDEV FCIOA OPT_CLN
Servicer Response: The device indicated that a format is in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 2107FFF3 FRU List: FCDEV 2107FFF4 Disk device problem Disk media format bad
21073029
Servicer Response: No action required. This reference code is logged for information only. 21073100 FRU List: FCINTF FCDEV FCIOA OPT_CLN 21073109 FRU List: FCDEV FCINTF FCIOA IOP timed out a disk command Fibre Channel interface error occurred
FRU List: FCDEV 2107FFF5 FRU List: FCDEV 2107FFF6 Disk device detected recoverable error Disk sector read error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: FCDEV 2107FFFA Disk device wrong response was recovered by the IOP
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code.
78
2107FFFE 25A80201
FRU List: FCDEV FCIOA OPT_CLN 2107FFFE Temporary Fibre Channel interface error FRU List: FCINTF FCDEV FCIOA OPT_CLN
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code.
(220x, 25Ax, 25Cx, 2602) Model 185 and A50 reference (error) codes
Model 185 and A50 reference (error) codes
22000001 PCI Ethernet adapter failure 22011001 PCI token ring adapter failure
Servicer Response: Replacethe adapter. 25A00001 L2 cache controller failure. Do the following:
Servicer Response: 1. Check for system firmware updates, and apply if available. 2. Replace the system backplane. FRU List: SYSBKP2 25A10001 Cache L2 SRAM failure
Servicer Response: v If the location code reported with the error specifies the adapter in the PCI slot, replace that adapter. v If the location code specifies the integrated Ethernet, replace the system backplane. FRU List: SYSBKP2 22003003 Gigabit Ethernet adapter failure
Servicer Response: 1. Check for system firmware updates, and apply if available. 2. Replace the system backplane. FRU List: SYSBKP2 25A80000 Initialization failed, device test failed
Servicer Response: If thereis an adapter plugged into the PCI slot in the system, remove it. Then power the system back up. v If this error code does not occur again, replace the PCI adapter card that you removed. v If this error code occurs again, replace the system backplane. FRU List: SYSBKP2 22010001 PCI token ring adapter failure
Servicer Response: Refer to the actions for error code 25A80xxx. 25A80100 NVRAM data validation check failed.
Servicer Response: Do thefollowing: 1. Before replacing any system component, turn off and then turn on the system unit. Then, retry the operation. 2. If the problem persists, refer to the actions for error code 25A80xxx. 25A80201 Unable to expand target partition:
Chapter 3. 2xxx Reference Codes
79
25A80202 25C0xxyy
saving configurationvariable Servicer Response: Refer to the actions for error code 25A80xxx. 25A80202 Unable to expand target partition: writing error logentry 25A80xxx NVRAM problems
Servicer Response: Refer to the actions for error code 25A80xxx. 25A80203 Unable to expand target partition: writing VPD data
Servicer Response: Errors reported against NVRAM can be caused by low battery voltage and (more rarely) power outages that occur during normal system usage. With the exception of the 25A80000 error, these errors are warnings that the NVRAM data had to be reestablished and do not require any FRU replacement unless the error is persistent. When one of these errors occurs, any system customization (for example, boot device list) information has been lost. If the error is persistent, replace the system backplane. FRU List: SYSBKP2 25C00000 No DIMMs detected.
Servicer Response: Refer to the actions for error code 25A80xxx. 25A80210 Setenv/$Setenv parameter error: name contains a nullcharacter
Servicer Response: Refer to the actions for error code 25A80xxx. 25A80211 Setenv/$Setenv parameter error: name contains a nullcharacter
Servicer Response: Do the following: 1. Ensure that all DIMMs are properly seated. Reseat them if necessary, and reboot the system. 2. Replace the DIMMs one at a time until the failing DIMM is isolated. 3. Replace the system backplane. FRU List: SYSBKP2 25C0xxyy DIMM failure.
Servicer Response: Refer to the actions for error code 25A80xxx. 25A80998 NVRAMRC script evaluation error: command line executionerror
Servicer Response: Running of a command line within the nvram configurationvariable nvramrc (script) resulted in a throw being run. This script can be modified by the firmware SMS utilities, the operating system, a PCI adapter ROM code or utility, or an operator (by using the open firmware script editing command nvedit). Resolving the problem may not be possible without a detailed analysis of the NVRAM script, the current system configuration, and device tree contents. Contact your next level of support for assistance. FRU List: NEXTLVL 25A80999 NVRAMRC script evaluation error: stack unbalanced oncompletion
Servicer Response: DIMM failure, where xx and yy indicate: xx Description------------------- 01 DIMM2 missing 10 DIMM1 missing 12 DIMM1 not supported 14 DIMM1 failed 21 DIMM2 not supported 22 DIMM1 and DIMM2 unsupported 41 DIMM2 failed 88 DIMM1 and DIMM2 mismatch yy Description ------------------- 01 DIMM4 missing 10 DIMM3 missing 12 DIMM3 not supported 14 DIMM3 failed 21 DIMM4 not supported 22 DIMM3 and DIMM4 unsupported 41 DIMM4 failed 88 DIMM3 and DIMM4 mismatch Do the following: 1. Verify that the DIMMs in the system are supported. Replace all unsupported DIMMs, then reboot the system. 2. Verify that the DIMMs are installed in pairs. If they are not, properly install the DIMMs. Reboot the system. 3. Ensure that the DIMMs are properly seated; reseat if necessary. Reboot the system. 4. If the problem persists, replace the system backplane. FRU List: SYSBKP2
Servicer Response: This is a firmware debug environment error. No useraction or FRU replacement exists for this error. If this error persists, call your next level of support. FRU List: NEXTLVL
80
25C10001 26891307
25C10001 Memory DIMM failure 3. Replace the companion of the DIMM specified by the location code. 4. Replace the DIMM specified by the location code. 5. If the problem persists, replace the system backplane. FRU List: SYSBKP2 26020008 PCI device fcode evaluation error.
Servicer Response: 1. Ensure that the DIMMs are properly seated; reseat if necessary. Reboot the system. 2. Replace the DIMM specified by the location code, then reboot the system. 3. Replace the companion DIMM in the pair, then reboot the system. 4. If the problem persists, replace the system backplane. FRU List: SYSBKP2 25C10002 Memory DIMM is not supported
Servicer Response: v If the location code identifies a slot, do the following: 1. Reseat the adapter and reboot the system. 2. Replace the adapter. 3. Check for system firmware updates, and apply if available. 4. If the problem persists, replace the system backplane. v If the location code identifies the system backplane, replace the system backplane. FRU List: SYSBKP2 26020009 The PCI adapter Fcode left a data stack imbalance.
Servicer Response: 1. Verify that the DIMMs in the system are supported. Replace all unsupported DIMMs, then reboot the system. 2. Verify that the DIMMs are installed in one or more pairs. If they are not, properly install the DIMMs, then reboot the system. 3. If the problem persists, replace the system backplane. FRU List: SYSBKP2 25C10003 The companion (in the pair) of the memory DIMM specifiedby the location code is failing, unsupported, missing, or unmatched.
Servicer Response: Dothe following: 1. Check for adapter microcode updates, and apply if available. Note: Using the adapter for booting is not recommended until after you install the new adapter microcode. 2. If no microcode updates are available, or if installing new microcode does not correct the problem, replace the PCI adapter.
Servicer Response: Dothe following: 1. Verify that the DIMMs in the system are supported. Replace all unsupported DIMMs, then reboot the system. 2. Verify that the DIMMs are installed in one or more pairs. If they are not, properly install the DIMMs, then reboot the system.
FRU List: AJDGP01 AJDG301 2689 I/O adapter resource not available.
81
26891310 26896202
AJDG301 26891310 I/O adapter resource not available. 26896070 FRU List: 2689 26896071 FRU List: AJDGP01 26896072 An I/O adapter failure occurred. FRU List: AJDGP01 2689 26896075 26893001 FRU List: 2689 AJDGP01 26893006 FRU List: 2689 ANYBUS 26893080 FRU List: AJDGP01 26893081 26893084 FRU List: AJDGP01 2689 26893087 FRU List: AJDGP01 AJDG301 NTUSER I/O adapter resource not available. I/O adapter error; logged only. An I/O adapter failure occurred. FRU List: 2689 AJDGP01 26896202 FRU List: AJDGP01 2689 I/O processor Licensed Internal Code error I/O adapter Licensed Internal Code failed. FRU List: AJDGP01 2689 26896201 A permanent I/O processor failure occurred An I/O adapter failure occurred. 2689 26896085 I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. FRU List: AJDGP01 26896083 FRU List: AJDGP01 I/O adapter Licensed Internal Code failed. I/O adapter resource not available. I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. An I/O adapter failure occurred.
Servicer Response: The INA processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. FRU List: 2689 AJDGP01 26893000 FRU List: 2689 AJDGP01
82
26896203 26896533
26896203 FRU List: NETSERV 2689 AJDGP01 26896210 FRU List: NETSERV AJDGP01 26896222 FRU List: AJDGP01 2689 26896223 FRU List: 2689 AJDGP01 26896225 FRU List: AJDGP01 AJDG301 2689 26896226 FRU List: AJDG301 AS4NTDD 26896227 FRU List: NTUSER AJDGP01 2689 A HostLAN error was detected I/O processor card detected device error A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error A permanent I/O processor failure occurred 26896228 FRU List: AJDGP01 2689 26896501 FRU List: 2689 AJDGP01 26896502 FRU List: AJDGP01 2689 26896530 FRU List: NTVSCSI NTOPSYS 26896531 FRU List: NTVSCSI AS4NTDD NTOPSYS AJDGP01 26896532 FRU List: NTOPSYS AJDGP01 AS4NTDD 26896533 FRU List: NTUSER NTOPSYS AS4NTDD A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Windows fatal error occurred A Windows fatal error occurred The Windows operating system initiated a warm boot
83
26896534 26896544
26896534 FRU List: AS4NTDD AJDGP01 NTOPSYS 26896535 FRU List: NTUSER NTDEVDR AJDGP01 26896538 FRU List: NTVSCSI NTOPSYS 26896539 FRU List: NTVSCSI AS4NTDD NTOPSYS AJDGP01 2689653A FRU List: NTOPSYS AJDGP01 AS4NTDD AJDGP01 2689653B FRU List: NTUSER NTOPSYS NTVSCSI AS4NTDD 26896544 2689653C FRU List: AS4NTDD A Virtual SCSI error was detected FRU List: NTVSCSI NTOPSYS A Virtual SCSI error was detected A Virtual SCSI error was detected 26896543 FRU List: NTOPSYS A Windows fatal error occurred A Virtual SCSI error was detected 26896541 FRU List: 2689 AJDGP01 26896542 FRU List: AJDG301 Licensed Internal Code error detected. A permanent I/O processor failure occurred A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected AJDGP01 NTOPSYS 2689653D FRU List: NTUSER NTDEVDR AJDGP01 2689653F FRU List: NTDEVDR NTOPSYS AJDG301 26896540 FRU List: NTVSCSI AJDGP01 AJDG301 A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected
84
26896580 2689B4B0
26896580 FRU List: DISKIMG 2689 AJDGP01 26896590 268965B0 FRU List: NTLANDD NTOPSYS 268965B1 FRU List: NTLANDD NTOPSYS AJDG301 268965B2 FRU List: NTDEVDR NTOPSYS AJDG301 26898301 FRU List: AJDGP01 2689 2689B3B1 FRU List: 2689 2689B3B2 FRU List: 2689 A permanent I/O processor failure occurred A permanent I/O processor failure occurred An I/O adapter failure occurred. A HostLAN error was detected FRU List: 2689 2689B3B8 FRU List: 2689 2689B3B9 FRU List: 2689 2689B3E0 FRU List: 2689 2689B3E1 FRU List: 2689 2689B4B0 FRU List: 2689 I/O adapter hardware error detected An I/O adapter failure occurred. I/O processor detected a fault condition A permanent I/O processor failure occurred An I/O adapter failure occurred. A HostLAN error was detected A Netfinity Server error was detected A HostLAN error was detected 2689B3B4 FRU List: 2689 2689B3B5 FRU List: 2689 2689B3B6 FRU List: 2689 2689B3B7 A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A Windows fatal error occurred 2689B3B3 FRU List: 2689 A permanent I/O processor failure occurred
85
2689B4B1 2744B920
2689B4B1 FRU List: NETSERV AJDGP01 2689B4B9 FRU List: 2689 2689B4BC FRU List: NETSERV 2689B4BF FRU List: NSCABLE 2689B904 FRU List: A permanent I/O processor failure occurred A Netfinity Server error was detected A Netfinity Server error was detected FRU List: AJDGP01 2689 2689BE00 FRU List: AJDGP01 2689 An I/O adapter failure occurred. An I/O adapter failure occurred. A Netfinity Server error was detected AJDGP01 2689 2689B935 FRU List: AJDGP01 2689 2689B960 I/O processor Licensed Internal Code error Incompatible hardware detected.
86
2744B921 2743B951
FI00718 FI00719 2744B921 FRU List: FI00719 FI00718 I/O adapter hardware error detected AJDGP01 MA_BRDG 2744B934 FRU List: FI00719 FI00718 Incompatible hardware detected.
87
2760B950 2746B904
2760B950 FRU List: AJDGP01 FI00718 FI00719 2760B951 I/O adapter hardware error detected Licensed Internal Code error FRU List: FI00719 FI00718 AJDGP01 MA_BRDG
88
2746B934 27483022
FI00719 2746B934 FRU List: FI00719 FI00718 2746B940 FRU List: FI00719 FI00718 AJDGP01 MA_BRDG I/O adapter hardware error detected Incompatible hardware detected. 2746B941 FRU List: FI00719 FI00718 AJDGP01 2746B942 FRU List: FI00719 FI00718 AJDGP01 One half of I/O adapter failed. One half of I/O adapter failed.
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27483006 FRU List: IOP ANYBUS STORIOA 27483020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27483022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
89
27483023 27483123
27483023 I/O processor detected a SCSI bus configuration error 27483103 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN
STORIOA 27483120 27483100 I/O processor card detected interface error I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 27483101 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27483121 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27483122 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 27483102 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27483123 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
90
27483140 27488012
27483140 I/O Processor detected that the bus is now operational FI01106 DEVTERM FI01140 27483401 FRU List: DEVBPLN 27483501 FRU List: AJDGP01 IOP 27483600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27483141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27483142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27483143 I/O Processor detected that the bus is now operational
27483601
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27483150 I/O processor detected a SCSI bus configuration error
27488008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27483151 I/O processor detected a SCSI bus configuration error
STORIOA 27488009 FRU List: CACHBAT 27488012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27483400 FRU List: FI02112 STORIOA I/O processor card detected device error
91
27488100 27488157
27488100 FRU List: AJDGP01 IOP 27488130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error 27488146 FRU List: FI01105 27488150 A permanent I/O processor failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27488131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27488132 IOA detected recoverable device bus error
27488151 FRU List: AJDGP01 STORIOA 27488155 FRU List: AJDGP01 STORIOA 27488156 FRU List: AJDGP01 STORIOA 27488157
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 27488133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27488140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27488141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27488145 FRU List: STORIOA A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the FRU List indicates I/O adapter, then replace the I/O adapter. If the FRU List indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to
92
27488200 27489022
re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27488200 FRU List: AJDGP01 IOP 27489000 FRU List: FI01105 STORIOA 27489001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error 27489009 FRU List: SVCDOCS 27489010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
FRU List: SVCDOCS 27489011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27489014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27489002 I/O processor card detected device error
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27489020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27489008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27489021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27489022 Array not functional due to present hardware configuration.
93
27489023 27489051
SVCDOCS 27489023 Array not functional due to present hardware configuration. 27489029 Incorrect hardware configuration change has been detected.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2748902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27489024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27489025 Disk unit is not supported at its physical location.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27489030 Array no longer protected due to missing or failed disk unit. Perform IOPIP21.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27489026 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 27489040 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27489027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 27489041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27489028 Incorrect hardware configuration change has been detected. FRU List: AJDGP01 27489050
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27489051 IOP cache data exists for a missing or failed device.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so,
94
27489052 27489092
perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27489052 Cache data exists for device that has been modified. 27489073 Incompatible or non-operational auxiliary cache IOA attached. Perform IOPIP40.
FRU List: SVCDOCS 27489081 FRU List: FI01105 STORIOA IOP resources not available due to previous problems. 27489082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27489053
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27489054 IOP resources not available due to previous problems.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27489090 Disk unit has been modified after the last known status.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27489071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27489091 Incorrect hardware configuration change has been detected.
Servicer Response: No service action required. 27489072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27489092 Disk unit requires initialization before use.
95
27489093 27573100
FRU List: SVCDOCS 27489093 Read cache device not in correct format STORIOA 27573021 Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2748B934 FRU List: STORIOA 2748FF3D FRU List: STORIOA ANYBRDG 2748FF6D FRU List: IOP ANYBUS 27571310 I/O processor resource not available I/O processor detected a recoverable system bus error I/O adapter detected a recoverable error Incompatible hardware detected. I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27573022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17>. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27573023 I/O processor detected a SCSI bus configuration error
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27573006 FRU List: IOP ANYBUS STORIOA 27573020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27573100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140
96
27573101 27573142
BACKPLN 27573101 I/O processor card detected interface error 27573121 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27573102 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27573122 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27573123 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27573103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27573140 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27573120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27573141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27573142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.
97
27573143 27578131
27573143 I/O Processor detected that the bus is now operational 27573600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27573150 I/O processor detected a SCSI bus configuration error
27573601
27578008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 27578009 FRU List: CACHBAT Impending cache battery pack failure
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27573151 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27573400 FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 27573401 FRU List: DEVBPLN 27573501 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error Device backplane problem I/O processor card detected device error
27578012
Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA.
FRU List: SVCDOCS 27578100 FRU List: AJDGP01 IOP 27578130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27578131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
98
27578132 27579000
27578132 IOA detected recoverable device bus error 27578151 FRU List: AJDGP01 STORIOA 27578133 IOA detected recoverable device bus error 27578155 FRU List: AJDGP01 STORIOA 27578156 FRU List: AJDGP01 STORIOA 27578157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only.
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27578140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27578141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27578145 FRU List: STORIOA 27578146 FRU List: FI01105 27578150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27578200 FRU List: AJDGP01 IOP 27579000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
99
27579001 27579025
27579001 I/O processor card detected device configuration error 27579015 Mode jumper missing
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27579002 I/O processor card detected device error
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27579020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27579008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27579021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27579022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27579009 FRU List: SVCDOCS 27579010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27579023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27579024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 27579011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27579025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27579014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
100
27579026 27579053
27579026 Array not functional due to present hardware configuration. 27579040 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27579027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 27579041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27579028 Incorrect hardware configuration change has been detected.
FRU List: AJDGP01 27579050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27579051 IOP cache data exists for a missing or failed device.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27579029 Incorrect hardware configuration change has been detected.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27579052 Cache data exists for device that has been modified.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2757902F Array addendum Product Activity Log entry
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27579030 Array no longer protected due to missing or failed disk unit. Perform IOPIP21.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27579053 IOP resources not available due to previous problems.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS
101
27579054 2757FF6D
27579054 IOP resources not available due to previous problems. 27579090 Disk unit has been modified after the last known status.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27579071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27579091 Incorrect hardware configuration change has been detected.
Servicer Response: No service action required. 27579072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27579092 Disk unit requires initialization before use.
Servicer Response: No service action required. 27579073 Incompatible or non-operational auxiliary cache IOA attached. Perform IOPIP40.
FRU List: SVCDOCS 27579081 FRU List: FI01105 STORIOA 27579082 I/O processor card detected device error I/O processor card detected device error
27579093
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2757B934 FRU List: STORIOA 2757FF3D FRU List: STORIOA ANYBRDG 2757FF6D FRU List: IOP ANYBUS I/O processor detected a recoverable system bus error I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
102
27631310 27633102
27631310 I/O processor resource not available STORIOA 27633023 I/O processor detected a SCSI bus configuration error
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27633006 FRU List: IOP ANYBUS STORIOA 27633020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27633100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27633021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27633101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27633022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27633102 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Chapter 3. 2xxx Reference Codes
103
27633103 27633400
27633103 I/O processor card detected interface error 27633140 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27633120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27633141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27633142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27633121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27633143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27633122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27633150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27633123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27633151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27633400 FRU List: FI02112 STORIOA I/O processor card detected device error
104
27633401 27638145
FI01106 DEVTERM FI01140 27633401 FRU List: DEVBPLN 27633501 FRU List: AJDGP01 IOP 27633600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error Device backplane problem FRU List: AJDGP01 IOP 27638130 IOA detected recoverable device bus error 27638100 I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27638131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27638132 IOA detected recoverable device bus error
27633601
27638008
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 27638133 IOA detected recoverable device bus error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 27638009 FRU List: CACHBAT 27638012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27638140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27638141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27638145 FRU List: STORIOA A recoverable I/O processor error occurred.
105
27638146 27639008
27638146 FRU List: FI01105 27638150 A permanent I/O processor failure occurred Disk device detected recoverable error re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27638200 FRU List: AJDGP01 IOP 27639000 FRU List: FI01105 STORIOA I/O processor Licensed Internal Code error 27639001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 27638151 FRU List: AJDGP01 STORIOA 27638155 FRU List: AJDGP01 STORIOA 27638156 FRU List: AJDGP01 STORIOA 27638157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27639002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27639008 I/O card does not support functions expected by devices
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to
106
27639009 27639028
27639009 FRU List: SVCDOCS 27639010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance SVCDOCS 27639023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27639024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 27639011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27639025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27639014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27639026 Array not functional due to present hardware configuration.
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27639020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27639027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27639021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27639028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27639022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS
107
27639029 27639072
27639029 Incorrect hardware configuration change has been detected. If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS Array addendum Product Activity Log entry 27639052 Cache data exists for device that has been modified.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2763902F
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27639030 Array no longer protected due to missing or failed disk unit. Perform IOPIP21.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27639053 IOP resources not available due to previous problems.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27639054 IOP resources not available due to previous problems.
Servicer Response: No action required. Protection will be automatically restarted. 27639040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 27639041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27639071 Link from IOA to auxiliary cache IOA went operational
FRU List: AJDGP01 27639050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27639051 IOP cache data exists for a missing or failed device.
Servicer Response: No service action required. 27639072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response:
108
27639073 27783020
27639073 Incompatible or non-operational auxiliary cache IOA attached. Perform IOPIP40. FRU List: SVCDOCS 27639093 Read cache device not in correct format
FRU List: SVCDOCS 27639081 FRU List: FI01105 STORIOA 27639082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2763B934 FRU List: STORIOA 2763FF3D FRU List: STORIOA ANYBRDG I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
27639090
Disk unit has been modified after the last known status.
27781310
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27639091 Incorrect hardware configuration change has been detected.
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27783006 FRU List: IOP ANYBUS STORIOA 27783020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27639092 Disk unit requires initialization before use.
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
109
27783021 27783120
STORIOA 27783021 I/O processor detected a SCSI bus configuration error BACKPLN 27783101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 27783102 27783022 I/O processor detected a SCSI bus configuration error I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27783023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27783103 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27783100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27783120 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
110
27783121 27783501
27783121 I/O Processor detected that the bus is not operational 27783143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27783122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27783150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27783123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27783151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27783140 I/O Processor detected that the bus is now operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27783400 FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 27783401 FRU List: DEVBPLN 27783501 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error. Device backplane problem I/O processor card detected device error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27783141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27783142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.
111
27783600 27788150
27783600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred 27788132 IOA detected recoverable device bus error
27783601
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 27788133 IOA detected recoverable device bus error
27788008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 27788009 FRU List: CACHBAT 27788012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27788140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27788141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27788145 FRU List: STORIOA 27788146 FRU List: FI01105 I/O processor Licensed Internal Code error 27788150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
FRU List: SVCDOCS 27788100 FRU List: AJDGP01 IOP 27788130 IOA detected recoverable device bus error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27788131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
112
27788151 27789014
27788151 FRU List: AJDGP01 STORIOA 27788155 FRU List: AJDGP01 STORIOA 27788156 FRU List: AJDGP01 STORIOA 27788157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error 27789001 I/O processor card detected device configuration error
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27789002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27789008 I/O card does not support functions expected by devices
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27788200 FRU List: AJDGP01 IOP 27789000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27789009 FRU List: SVCDOCS 27789010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
FRU List: SVCDOCS 27789011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27789014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
113
27789015 27789031
27789015 Mode jumper missing 27789026 Array not functional due to present hardware configuration.
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27789020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27789027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27789021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27789028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27789022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27789029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27789023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2778902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27789024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27789030 Array no longer protected due to missing or failed disk unit. Perform IOPIP21.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27789025 Disk unit is not supported at its physical location.
114
27789040 27789082
27789040 Array protection temporarily suspended 27789054 IOP resources not available due to previous problems.
Servicer Response: No action required. Protection will be automatically restarted. 27789041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS
FRU List: AJDGP01 27789050 Required cache data cannot be located for a disk unit.
27789071
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27789051 IOP cache data exists for a missing or failed device.
Servicer Response: No service action required. 27789072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27789052 Cache data exists for device that has been modified.
Servicer Response: No service action required. 27789073 Incompatible or non-operational auxiliary cache IOA attached. Perform IOPIP40.
FRU List: SVCDOCS 27789081 FRU List: FI01105 STORIOA 27789082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27789053 IOP resources not available due to previous problems.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS
115
27789090 27803022
27789090 Disk unit has been modified after the last known status. 27801310 I/O processor resource not available
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27789091 Incorrect hardware configuration change has been detected.
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27803006 FRU List: IOP ANYBUS STORIOA 27803020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27789092 Disk unit requires initialization before use.
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27803021 I/O processor detected a SCSI bus configuration error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 27789093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2778B934 FRU List: STORIOA 2778FF3D FRU List: STORIOA ANYBRDG 2778FF6D FRU List: IOP ANYBUS I/O processor detected a recoverable system bus error I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27803022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
116
27803023 27803123
STORIOA 27803023 I/O processor detected a SCSI bus configuration error 27803103 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27803100 I/O processor card detected interface error
27803120
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27803101 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27803121 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27803122 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27803123 I/O Processor detected that the bus is not operational
27803102
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
117
27803140 27808012
27803140 I/O Processor detected that the bus is now operational FI01106 DEVTERM FI01140 27803401 FRU List: DEVBPLN 27803501 FRU List: AJDGP01 IOP 27803600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27803141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27803142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27803143 I/O Processor detected that the bus is now operational
27803601
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27803150 I/O processor detected a SCSI bus configuration error
27808008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27803151 I/O processor detected a SCSI bus configuration error
STORIOA 27808009 FRU List: CACHBAT 27808012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27803400 FRU List: FI02112 STORIOA I/O processor card detected device error
118
27808100 27808157
27808100 FRU List: AJDGP01 IOP 27808130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error 27808146 FRU List: FI01105 27808150 A permanent I/O processor failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27808131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27808132 IOA detected recoverable device bus error
27808151 FRU List: AJDGP01 STORIOA 27808155 FRU List: AJDGP01 STORIOA 27808156 FRU List: AJDGP01 STORIOA 27808157
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 27808133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27808140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27808141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27808145 FRU List: STORIOA A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to
119
27808200 27809022
re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27808200 FRU List: AJDGP01 IOP 27809000 FRU List: FI01105 STORIOA 27809001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error 27809009 FRU List: SVCDOCS 27809010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
FRU List: SVCDOCS 27809011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27809014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27809002 I/O processor card detected device error
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27809020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27809008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27809021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27809022 Array not functional due to present hardware configuration.
120
27809023 27809050
SVCDOCS 27809023 Array not functional due to present hardware configuration. 27809029 Incorrect hardware configuration change has been detected.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2780902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27809024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27809025 Disk unit is not supported at its physical location.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27809030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27809026 Array not functional due to present hardware configuration.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 27809031 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27809027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 27809040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27809028 Incorrect hardware configuration change has been detected.
Servicer Response: No action required. Protection will be automatically restarted. 27809041 Background array parity check detected and corrected errors.
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 27809050 Required cache data cannot be located for a disk unit.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS
121
27809051 27809091
27809051 IOP cache data exists for a missing or failed device. 27809073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27809052 Cache data exists for device that has been modified.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 27809081 FRU List: FI01105 STORIOA 27809082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27809053 IOP resources not available due to previous problems.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 IOP resources not available due to previous problems. 27809090 Disk unit has been modified after the last known status.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27809054
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27809071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27809091 Incorrect hardware configuration change has been detected.
Servicer Response: No service action required. 27809072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
122
27809092 27823100
27809092 Disk unit requires initialization before use. FRU List: USER FI01107 STORIOA 27823021 27809093 Read cache device not in correct format I/O processor detected a SCSI bus configuration error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2780B934 FRU List: STORIOA 2780FF3D FRU List: STORIOA ANYBRDG 2780FF6D FRU List: IOP ANYBUS 27821310 I/O processor resource not available I/O processor detected a recoverable system bus error I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27823022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27823023 I/O processor detected a SCSI bus configuration error
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27823006 FRU List: IOP ANYBUS STORIOA 27823020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27823100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List:
Chapter 3. 2xxx Reference Codes
123
27823101 27823142
FI01107 STORIOA FI01140 BACKPLN 27823101 I/O processor card detected interface error 27823121 I/O Processor detected that the bus is not operational FRU List: SVCDOCS
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27823122 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27823102 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27823123 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27823103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27823140 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27823120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27823141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27823142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device.
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.
124
27823143 27828131
27823143 I/O Processor detected that the bus is now operational 27823600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27823150 I/O processor detected a SCSI bus configuration error
27823601
27828008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 27828009 FRU List: CACHBAT Impending cache battery pack failure
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27823151 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27823400 FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 27823401 FRU List: DEVBPLN 27823501 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error Device backplane problem I/O processor card detected device error
27828012
Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA.
FRU List: SVCDOCS 27828100 FRU List: AJDGP01 IOP 27828130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27828131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
125
27828132 27829000
27828132 IOA detected recoverable device bus error 27828151 FRU List: AJDGP01 STORIOA 27828133 IOA detected recoverable device bus error 27828155 FRU List: AJDGP01 STORIOA 27828156 FRU List: AJDGP01 STORIOA 27828157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only.
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27828140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 27828141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 27828145 FRU List: STORIOA 27828146 FRU List: FI01105 27828150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27828200 FRU List: AJDGP01 IOP 27829000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
126
27829001 27829025
27829001 I/O processor card detected device configuration error 27829015 Mode jumper missing
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27829002 I/O processor card detected device error
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 27829020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27829008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27829021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27829022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27829009 FRU List: SVCDOCS 27829010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27829023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27829024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 27829011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27829025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27829014 Mode jumper overridden due to cache data in conflicting mode. See JOVERRIDE.
127
27829026 27829053
27829026 Array not functional due to present hardware configuration. 27829031 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27829027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 27829040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 27829041 Background array parity check detected and corrected errors.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27829028 Incorrect hardware configuration change has been detected.
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 27829050 Required cache data cannot be located for a disk unit.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27829029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27829051 IOP cache data exists for a missing or failed device.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2782902F Array addendum Product Activity Log entry
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27829052 Cache data exists for device that has been modified.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27829030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 27829053 IOP resources not available due to previous problems.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them.
128
27829054 2782FF3D
FRU List: SVCDOCS 27829054 IOP resources not available due to previous problems. FI01106 27829090 Disk unit has been modified after the last known status.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27829071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27829091 Incorrect hardware configuration change has been detected.
Servicer Response: No service action required. 27829072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27829092 Disk unit requires initialization before use.
Servicer Response: No service action required. 27829073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 27829081 FRU List: FI01105 STORIOA 27829082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 27829093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2782B934 FRU List: STORIOA 2782FF3D FRU List: STORIOA ANYBRDG I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN
129
2782FF6D 57033101
2782FF6D FRU List: IOP ANYBUS 57031310 I/O processor resource not available I/O processor detected a recoverable system bus error 57033022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57033023 I/O processor detected a SCSI bus configuration error
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57033006 FRU List: IOP ANYBUS STORIOA 57033020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57033100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57033021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
130
57033102 57033151
57033102 I/O processor card detected interface error 57033123 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033140 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 57033141 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 57033142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 57033143 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 57033150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033122 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57033151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration.
Chapter 3. 2xxx Reference Codes
131
57033400 57038140
FRU List: SVCDOCS 57033400 FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 57033401 FRU List: DEVBPLN 57033501 FRU List: AJDGP01 IOP 57033600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error Device backplane problem FRU List: SVCDOCS 57038100 FRU List: AJDGP01 IOP 57038130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error I/O processor card detected device error 57038009 FRU List: CACHBAT 57038012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 57038131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57038132 IOA detected recoverable device bus error
57033601
57038008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57038133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 57038140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only.
132
57038141 57039002
57038141 IOA detected recoverable device error 57038157 I/O adapter card error
Servicer Response: No action is required. This reference code is logged for information only. 57038145 FRU List: STORIOA 57038146 FRU List: FI01105 57038150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57038200 FRU List: AJDGP01 IOP 57039000 FRU List: FI01105 STORIOA 57039001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 57038151 FRU List: AJDGP01 STORIOA 57038155 FRU List: AJDGP01 STORIOA 57038156 FRU List: AJDGP01 STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57039002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
133
57039008 57039028
57039008 I/O card does not support functions expected by devices SVCDOCS 57039022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 57039009 FRU List: SVCDOCS 57039010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 57039011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 57039014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 57039026 Array not functional due to present hardware configuration.
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 57039020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57039021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57039028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP.
134
57039029 57039072
FRU List: SVCDOCS 57039029 Incorrect hardware configuration change has been detected. SVCDOCS 57039051 IOP cache data exists for a missing or failed device.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5703902F Array addendum Product Activity Log entry
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 57039052 Cache data exists for device that has been modified.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57039030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57039053 IOP resources not available due to previous problems.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57039031 Array protection temporarily suspended
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57039054 IOP resources not available due to previous problems.
Servicer Response: No action required. Protection will be automatically restarted. 57039040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 57039041 Background array parity check detected and corrected errors.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57039071 Link from IOA to auxiliary cache IOA went operational
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 57039050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 57039072 Link from IOA to auxiliary cache IOA went non-operational
135
57039073 57093020
57039073 Incompatible or non-operational auxiliary cache IOA attached. 57039092 Disk unit requires initialization before use.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57039081 FRU List: FI01105 STORIOA 57039082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 57039093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5703B934 FRU List: STORIOA 5703FF3D FRU List: STORIOA ANYBRDG 5703FF6D FRU List: IOP I/O processor detected a recoverable system bus error I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57039090 Disk unit has been modified after the last known status.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57039091 Incorrect hardware configuration change has been detected.
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57093006 FRU List: IOP ANYBUS STORIOA 57093020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices.
136
57093021 57093120
FRU List: USER FI01107 FI01140 STORIOA BACKPLN 57093021 I/O processor detected a SCSI bus configuration error 57093101 I/O processor card detected interface error FI01107 STORIOA
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57093022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093102 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57093023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093103 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093120 I/O Processor detected that the bus is not operational
57093100
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List:
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device.
137
57093121 57093501
FRU List: SVCDOCS 57093121 I/O Processor detected that the bus is not operational 57093143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 57093150 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57093151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 57093400 FRU List: FI02112 STORIOA I/O processor card detected device error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093140 I/O Processor detected that the bus is now operational
FI01106 DEVTERM FI01140 57093401 FRU List: DEVBPLN 57093501 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 57093141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 57093142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational.
138
57093600 57098150
57093600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred 57098132 IOA detected recoverable device bus error
57093601
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57098133 IOA detected recoverable device bus error
57098008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 57098009 FRU List: CACHBAT 57098012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 57098140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 57098141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 57098145 FRU List: STORIOA 57098146 FRU List: FI01105 I/O processor Licensed Internal Code error 57098150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
FRU List: SVCDOCS 57098100 FRU List: AJDGP01 IOP 57098130 IOA detected recoverable device bus error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 57098131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
139
57098151 57099014
57098151 FRU List: AJDGP01 STORIOA 57098155 FRU List: AJDGP01 STORIOA 57098156 FRU List: AJDGP01 STORIOA 57098157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error 57099001 I/O processor card detected device configuration error
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57099002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57099008 I/O card does not support functions expected by devices
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57098200 FRU List: AJDGP01 IOP 57099000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 57099009 FRU List: SVCDOCS 57099010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
FRU List: SVCDOCS 57099011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 57099014 Mode jumper overridden due to cache data in conflicting mode. See JOVERRIDE.
140
57099015 57099030
57099015 Mode jumper missing 57099026 Array not functional due to present hardware configuration.
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 57099020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57099021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57099028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57099022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 57099029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5709902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57099030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099025 Disk unit is not supported at its physical location.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS
141
57099031 57099082
57099031 Array protection temporarily suspended SVCDOCS 57099054 IOP resources not available due to previous problems.
Servicer Response: No action required. Protection will be automatically restarted. 57099040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 57099041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57099071 Link from IOA to auxiliary cache IOA went operational
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 57099050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 57099072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 57099051 IOP cache data exists for a missing or failed device.
Servicer Response: No service action required. 57099073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57099081 I/O processor card detected device error
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 57099052 Cache data exists for device that has been modified.
FRU List: FI01105 STORIOA 57099082 I/O processor card detected device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57099053 IOP resources not available due to previous problems.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List:
142
57099090 5709FF6D
FI01106 57099090 Disk unit has been modified after the last known status. 5709FF6D FRU List: IOP ANYBUS I/O processor detected a recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57099091 Incorrect hardware configuration change has been detected.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57099092 Disk unit requires initialization before use.
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 57099093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5709B934 FRU List: STORIOA 5709FF3D FRU List: STORIOA ANYBRDG I/O adapter detected recoverable error Incompatible hardware detected.
143
27490A17 27493000
If the error is reported on the control panel, the reference code is characters 1 through 8 of the top 16 character line of function 11. If the error is reported on the console, the reference code is the 8 rightmost characters of word 1. Note: The 673x is a read cache. Perform all actions required for 673x as a disk drive and logic card except where separate 673x cache instructions are provided.
27490A17 FRU List: IOP MA_BRDG AJDGP01 AJDG301 27490A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 2749102E FRU List: FI01105 27491306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage 27492200 FRU List: AJDGP01 27492201 FRU List: USER FI01105 27492202 FRU List: FI00022 FI01105 I/O processor resource not available 27493000 FRU List: FI01101 IOP 27491310 I/O processor resource not available A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error I/O processor detected a storage transfer error A permanent I/O processor failure occurred Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27491317 I/O processor card error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 BACKPLN 27491307 FRU List: AJDGP01 AJDG301
144
27493001 27493081
MA_BRDG 27493001 Not valid condition in I/O Processor Licensed InternalCode 27493021 I/O processor detected a SCSI bus configuration error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 27493002 Addressed device failed to respond to selection
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27493022 I/O processor detected a SCSI bus configuration error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 FI01141 FI01106 27493006 FRU List: IOP ANYBUS FI01101 27493020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27493023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27493080 FRU List: AJDGP01 27493081 System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
145
27493084 27493110
27493084 I/O processor card or Licensed Internal Code error 27493102 I/O processor card detected interface error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140
FI01104 BACKPLN MA_BRDG 27493103 27493087 I/O processor resource not available Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 FI01140 IOACNFG BACKPLN FI01104 27493109 27493100 I/O processor card detected interface error I/O processor timed out a device command I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA
FI01140 BACKPLN BACKPLN FI01106 27493101 I/O processor card detected interface error 27493110 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA
146
27493120 27493200
FI01106 27493120 I/O Processor detected that the bus is not operational 27493141 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27493121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27493142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27493143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27493122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27493150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27493123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27493151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27493136 FRU List: USER FI01105 The removable media device is assigned elsewhere
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27493200 FRU List: FI01105 STORIOA A tape/CD or disk device reported a failure
27493140
IOP MEDIA
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.
147
27493203 27496076
27493203 FRU List: FI01105 27493205 Disk sector read error Disk media format bad 27493401 FRU List: DEVBPLN 27493501 FRU List: AJDGP01 IOP 27493600 System log entry only, no service action required. System log entry only, no service action required. A permanent I/O processor failure occurred I/O processor Licensed Internal Code error Device backplane problem
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 27493215 Disk sector read error
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 27493250 Disk unit requires initialization before use.
27493601
27496070 FRU List: IOP 27496071 FRU List: AJDGP01 Storage unit detected a media problem 27496072 FRU List: AJDGP01 IOP 27496073 I/O processor card detected device error FRU List: MEDIA FI01105
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 27493300
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 27493400
Servicer Response: Note: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 27496076 DEVTERM FI01140 FRU List: MEDIA AJDGP01 I/O processor card detected media error
USER 27496075 FRU List: AJDGP01 I/O processor resource not available
148
27496081 27498007
FI01105 27496081 FRU List: AJDGP01 IOP 27496082 FRU List: AJDGP01 IOP 27496083 FRU List: AJDGP01 IOP 27498004 27496085 FRU List: AJDGP01 IOP MA_BRDG 27496200 FRU List: FCIOA OPT_CLN 27496201 FRU List: AJDGP01 27496602 FRU List: AJDGP01 An I/O processor Licensed Internal Code error occurred. IOA LID is not valid 27498007 A recoverable cache adaptor card error occurred. A permanent IOA hardware error occurred 27498005 A recoverable IOP or cache adaptor card error occurred. I/O processor Licensed Internal Code error FRU List: FI01141 STORIOA Voltage drop detected on I/O processor 5 volt powersupply. I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error 27498000 A permanent IOP or cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 27498002 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
149
27498010 27498155
27498010 A permanent cache adaptor card failure occurred. 27498133 IOA detected recoverable device bus error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27498011 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27498140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 27498141 IOA detected recoverable device error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27498100 FRU List: AJDGP01 IOP 27498130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: No actionis required. This reference code is logged for information only. 27498145 FRU List: STORIOA 27498146 FRU List: FI01105 27498150 FRU List: STORIOA ANYBRDG 27498151 FRU List: AJDGP01 STORIOA 27498155 FRU List: AJDGP01 STORIOA A permanent I/O processor failure occurred I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27498131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27498132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only.
150
27498156 27499009
27498156 FRU List: AJDGP01 STORIOA 27498157 I/O adapter card error FRU List: AJDGP01 27499000 FRU List: FI01105 STORIOA 27499001 I/O processor card detected device configuration error I/O processor card detected device error A permanent I/O processor failure occurred AJDGP01 IOP 27498400 I/O processor Licensed Internal Code error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27498200 FRU List: AJDGP01 IOP 27498300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27499002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27499008 I/O card does not support functions expected by devices
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27499009 Call your next level of support for assistance
27498301
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101
151
27499010 27499029
27499010 Cache data associated with attached devices cannot befound. Perform IOPIP31. 27499023 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 27499011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27499024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27499012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27499025 Disk unit is not supported at its physical location.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 27499013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27499026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 27499020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27499027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27499021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27499028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27499022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27499029 Incorrect hardware configuration change has been detected.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS
152
2749902F 27499082
2749902F Array addendum Product Activity Log entry 27499052 Cache data exists for device that has been modified.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27499030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 27499053 IOP resources not available due to previous problems.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27499054 IOP resources not available due to previous problems.
Servicer Response: No actionrequired. Protection will be automatically restarted. 27499040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 27499041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27499081 I/O processor card detected device error
FRU List: AJDGP01 27499050 Required cache data cannot be located for a disk unit.
FRU List: FI01105 STORIOA 27499082 I/O processor card detected device error
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27499051 IOP cache data exists for a missing or failed device.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS
153
27499090 2749B411
27499090 Disk unit has been modified after the last known status. 2749B3B5 FRU List: IOP 2749B3B6 FRU List: IOP Incorrect hardware configuration change has been detected. 2749B3B7 FRU List: IOP 2749B3B8 FRU List: MA_BRDG Disk unit requires initialization before use. IOP 2749B3B9 FRU List: IOP 2749B3E0 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred 2749B3E1 FRU List: IOP A permanent I/O processor failure occurred MA_BRDG 2749B410 FRU List: STORIOA 2749B411 FRU List: STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27499091
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27499092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 2749B3B1 FRU List: IOP 2749B3B2 FRU List: IOP 2749B3B3 FRU List: IOP 2749B3B4 FRU List: IOP A permanent I/O processor failure occurred A permanent I/O processor failure occurred
154
2749B412 27671317
2749B412 Tape/CD or disk bus interface error occurred AJDGP01 AJDG301 27670A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 2749B935 FRU List: FI01101 AJDGP01 IOP MA_BRDG 2749BE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG 2749FF3D FRU List: STORIOA ANYBRDG 2749FF6D FRU List: IOP ANYBUS 27671317 27670A17 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred I/O processor card error I/O processor detected a recoverable system bus error. I/O adapter detected a recoverable error I/O processor detected a fault condition. Unknown hardware detected 2767102E FRU List: FI01105 27671306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage I/O processor detected a storage transfer error
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 BACKPLN 27671307 FRU List: AJDGP01 AJDG301 27671310 I/O processor resource not available I/O processor resource not available
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following:
155
27672200 27673022
1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27672200 FRU List: AJDGP01 27672201 FRU List: USER FI01105 27672202 FRU List: FI00022 FI01105 27673000 FRU List: FI01101 IOP MA_BRDG 27673001 Not valid condition in I/O Processor Licensed InternalCode A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error FI01105 STORIOA FI01140 FI01141 FI01106 27673006 FRU List: IOP ANYBUS FI01101 27673020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27673021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27673022 I/O processor detected a SCSI bus configuration error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 27673002 Addressed device failed to respond to selection
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List:
156
27673023 27673103
USER FI01107 STORIOA 27673023 I/O processor detected a SCSI bus configuration error 27673100 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27673101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27673080 FRU List: AJDGP01 27673081 System log entry only, no service action required. I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27673102 I/O processor card detected interface error
27673084
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27673103 I/O processor card detected interface error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 27673087 I/O processor resource not available
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104
157
27673109 27673143
27673109 I/O processor timed out a device command A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27673123 I/O Processor detected that the bus is not operational
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27673110 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27673136 FRU List: USER FI01105 27673140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27673120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 27673141 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27673121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27673142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27673122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27673143 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.
Servicer Response:
158
27673150 27673601
27673150 I/O processor detected a SCSI bus configuration error 27673250 Disk unit requires initialization before use.
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27673151 I/O processor detected a SCSI bus configuration error
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 27673300 Storage unit detected a media problem
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 27673400 I/O processor card detected device error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27673200 FRU List: FI01105 STORIOA IOP MEDIA 27673203 FRU List: FI01105 27673205 Disk sector read error Disk media format bad A tape/CD or disk device reported a failure
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 27673401 Device backplane problem
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 27673215 Disk sector read error
FRU List: DEVBPLN 27673501 FRU List: AJDGP01 IOP 27673600 System log entry only, no service action required. System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105
27673601
159
27676070 27678002
27676070 FRU List: IOP 27676071 FRU List: AJDGP01 27676072 FRU List: AJDGP01 IOP 27676073 FRU List: MEDIA FI01105 USER 27676075 FRU List: AJDGP01 27676076 FRU List: MEDIA AJDGP01 FI01105 27676081 FRU List: AJDGP01 IOP 27678002 27676082 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error A permanent cache adaptor card failure occurred. I/O processor Licensed Internal Code error Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE I/O processor card detected media error I/O processor resource not available 27676201 FRU List: AJDGP01 27676602 FRU List: AJDGP01 27678000 A permanent IOP or cache adaptor card failure occurred. An I/O processor Licensed Internal Code error occurred. IOA LID is not valid IPL device not ready I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error A permanent I/O processor failure occurred 27676083 FRU List: AJDGP01 IOP 27676085 FRU List: AJDGP01 IOP MA_BRDG 27676200 FRU List: FCIOA OPT_CLN A permanent IOA hardware error occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response:
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE
160
27678004 27678145
STORIOA 27678004 FRU List: FI01141 STORIOA 27678005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply. CACHE STORIOA 27678100 FRU List: AJDGP01 IOP 27678130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 27678007 A recoverable cache adaptor card error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27678131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27678132 IOA detected recoverable device bus error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27678010 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only. 27678133 IOA detected recoverable device bus error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27678011 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 27678140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 27678141 IOA detected recoverable device error
Servicer Response: No actionis required. This reference code is logged for information only. Perform IOPIP01. 27678145 FRU List: STORIOA A recoverable I/O processor error occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List:
161
27678146 27679001
27678146 FRU List: FI01105 27678150 FRU List: STORIOA ANYBRDG 27678151 FRU List: AJDGP01 STORIOA 27678155 FRU List: AJDGP01 STORIOA 27678156 FRU List: AJDGP01 STORIOA 27678157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error 27678200 FRU List: AJDGP01 IOP 27678300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01 27678301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101 AJDGP01 IOP 27678400 FRU List: AJDGP01 27679000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS
27679001
162
27679002 27679026
27679002 I/O processor card detected device error FRU List: SVCDOCS 27679020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27679008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27679021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27679022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27679009 FRU List: SVCDOCS 27679010 FRU List: SVCDOCS 27679011 Cache data belongs to devices other than those attached Cache data associated with attached devices cannot befound IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27679023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27679024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27679012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27679025 Disk unit is not supported at its physical location.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 27679013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27679026 Array not functional due to present hardware configuration.
163
27679027 27679054
SVCDOCS 27679027 Array not functional due to present hardware configuration. 27679041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27679028 Incorrect hardware configuration change has been detected.
FRU List: AJDGP01 27679050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27679051 IOP cache data exists for a missing or failed device.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27679029 Incorrect hardware configuration change has been detected.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 27679052 Cache data exists for device that has been modified.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2767902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 27679053 IOP resources not available due to previous problems.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27679030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27679054 IOP resources not available due to previous problems.
Servicer Response: No actionrequired. Protection will be automatically restarted. 27679040 Array protection temporarily suspended
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS
164
27679081 2767B3E0
27679081 FRU List: FI01105 STORIOA 2767B3B3 27679082 I/O processor card detected device error FRU List: IOP 2767B3B4 FRU List: IOP 2767B3B5 FRU List: IOP Disk unit has been modified after the last known status. 2767B3B6 FRU List: IOP 2767B3B7 FRU List: IOP 2767B3B8 FRU List: MA_BRDG IOP 2767B3B9 Disk unit requires initialization before use. FRU List: IOP 2767B3E0 FRU List: IOP A permanent I/O processor failure occurred MA_BRDG I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27679090 A permanent I/O processor failure occurred I/O processor card detected device error 2767B3B2 FRU List: IOP A permanent I/O processor failure occurred
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27679091 Incorrect hardware configuration change has been detected.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27679092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 2767B3B1 FRU List: IOP
165
2767B3E1 27681306
2767B3E1 FRU List: IOP MA_BRDG 2767B410 FRU List: STORIOA 2767B411 FRU List: STORIOA 2767B412 Tape/CD or disk bus interface error occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. 2767FF3D FRU List: STORIOA ANYBRDG 2767FF6D FRU List: IOP ANYBUS 27680A17 FRU List: IOP MA_BRDG AJDGP01 AJDG301 27680A22 FRU List: AJDGP01 AJDG301 2767B935 FRU List: FI01101 AJDGP01 2768102E IOP MA_BRDG 2767BE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG I/O processor detected a fault condition. FRU List: FI01105 27681306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage Unknown hardware detected IOP MA_BRDG I/O processor detected a storage transfer error A permanent I/O processor failure occurred I/O processor detected a recoverable system bus error. I/O adapter detected a recoverable error
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 BACKPLN
166
27681307 27683020
27681307 FRU List: AJDGP01 AJDG301 27681310 I/O processor resource not available I/O processor resource not available IOP MA_BRDG 27683001 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 27681317 I/O processor card error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27682200 FRU List: AJDGP01 27682201 FRU List: USER FI01105 27682202 FRU List: FI00022 FI01105 27683000 FRU List: FI01101 A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error
27683002
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 FI01141 FI01106 27683006 FRU List: IOP ANYBUS FI01101 27683020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
167
27683021 27683101
27683021 I/O processor detected a SCSI bus configuration error 27683084 I/O processor card or Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27683022 I/O processor detected a SCSI bus configuration error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 27683087 I/O processor resource not available
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27683023 I/O processor detected a SCSI bus configuration error
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104 27683100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 27683080 FRU List: AJDGP01 27683081 System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27683101 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
168
27683102 27683140
27683102 I/O processor card detected interface error FI01106 27683120 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27683103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27683121 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 27683109 I/O processor timed out a device command
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27683122 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27683123 I/O Processor detected that the bus is not operational
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27683110 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 27683136 FRU List: USER FI01105 27683140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.
169
27683141 27683400
27683141 I/O Processor detected that the bus is now operational 27683203 FRU List: FI01105 27683205 Disk sector read error Disk media format bad
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 27683142 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 27683215 Disk sector read error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 27683143 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 27683250 Disk unit requires initialization before use.
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 27683150 I/O processor detected a SCSI bus configuration error
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 27683300 Storage unit detected a media problem
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 27683151 I/O processor detected a SCSI bus configuration error
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 27683400 A tape/CD or disk device reported a failure I/O processor card detected device error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 27683200 FRU List: FI01105 STORIOA IOP MEDIA
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140
170
27683401 27686602
27683401 FRU List: DEVBPLN 27683501 FRU List: AJDGP01 IOP 27683600 System log entry only, no service action required. System log entry only, no service action required. A permanent I/O processor failure occurred I/O processor Licensed Internal Code error Device backplane problem FI01105 27686081 FRU List: AJDGP01 IOP 27686082 FRU List: AJDGP01 IOP 27683601 27686083 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error 27686085 FRU List: AJDGP01 I/O processor Licensed Internal Code error IOP MA_BRDG 27686200 FRU List: FCIOA OPT_CLN 27686201 FRU List: AJDGP01 I/O processor resource not available 27686602 FRU List: AJDGP01 I/O processor card detected media error An I/O processor Licensed Internal Code error occurred. IOA LID is not valid A permanent IOA hardware error occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error
27686070 FRU List: IOP 27686071 FRU List: AJDGP01 27686072 FRU List: AJDGP01 IOP 27686073 FRU List: MEDIA FI01105 USER 27686075 FRU List: AJDGP01 27686076 FRU List: MEDIA AJDGP01
171
27688000 27688132
27688000 A permanent IOP or cache adaptor card failure occurred. 27688010 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 27688002 A permanent cache adaptor card failure occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27688011 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27688004 FRU List: FI01141 STORIOA 27688005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 27688100 FRU List: AJDGP01 IOP 27688130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 27688007 A recoverable cache adaptor card error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 27688131 IOA detected recoverable device bus error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 27688132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only.
172
27688133 27688301
27688133 IOA detected recoverable device bus error 27688156 FRU List: AJDGP01 STORIOA 27688140 IOA detected recoverable device bus error 27688157 I/O adapter card error A permanent I/O processor failure occurred
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only.
Servicer Response: No actionis required. This reference code is logged for information only. 27688141 IOA detected recoverable device error
Servicer Response: No actionis required. This reference code is logged for information only. 27688145 FRU List: STORIOA 27688146 FRU List: FI01105 27688150 FRU List: STORIOA ANYBRDG A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 27688200 FRU List: AJDGP01 IOP 27688300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
27688151 FRU List: AJDGP01 STORIOA 27688155 FRU List: AJDGP01 STORIOA
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA
IOP AJDGP01 27688301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101
Chapter 3. 2xxx Reference Codes
173
27688400 27689022
AJDGP01 IOP 27688400 FRU List: AJDGP01 27689000 FRU List: FI01105 STORIOA 27689001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error FRU List: SVCDOCS 27689011 Cache data belongs to devices other than those attached 27689010 Cache data associated with attached devices cannot befound. Perform IOPIP31.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 27689012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 27689002 I/O processor card detected device error
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 27689013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 27689008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 27689020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27689021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 27689009 FRU List: SVCDOCS Call your next level of support for assistance
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 27689022 Array not functional due to present hardware configuration.
174
27689023 27689051
27689023 Array not functional due to present hardware configuration. 2768902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27689024 Array not functional due to present hardware configuration.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 27689030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27689025 Disk unit is not supported at its physical location. FRU List: SVCDOCS 27689031
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 27689026 Array not functional due to present hardware configuration.
Servicer Response: No actionrequired. Protection will be automatically restarted. 27689040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 27689041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 27689027 Array not functional due to present hardware configuration.
FRU List: AJDGP01 27689050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 27689028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 27689051 IOP cache data exists for a missing or failed device.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 27689029 Incorrect hardware configuration change has been detected.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS
Servicer Response: Contact your next level of support. FRU List: SVCDOCS
Chapter 3. 2xxx Reference Codes
175
27689052 2768B3B4
27689052 Cache data exists for device that has been modified. 27689090 Disk unit has been modified after the last known status.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 27689053 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem.If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27689091 Incorrect hardware configuration change has been detected.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27689054 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 27689092 Disk unit requires initialization before use.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 27689081 FRU List: FI01105 STORIOA 27689082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 2768B3B1 FRU List: IOP 2768B3B2 FRU List: IOP 2768B3B3 FRU List: IOP 2768B3B4 A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
176
2768B3B5 28420A17
2768B3B5 FRU List: IOP 2768B3B6 FRU List: IOP 2768B3B7 FRU List: IOP 2768B3B8 FRU List: MA_BRDG IOP 2768B3B9 FRU List: IOP 2768B3E0 FRU List: IOP MA_BRDG 2768FF3D 2768B3E1 FRU List: IOP MA_BRDG 2768FF6D 2768B410 FRU List: STORIOA 2768B411 FRU List: STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred FRU List: IOP ANYBUS 28420A17 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred I/O processor detected a recoverable system bus error. I/O processor detected a fault condition. FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 2768B412 Tape/CD or disk bus interface error occurred
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 2768B935 FRU List: FI01101 AJDGP01 IOP MA_BRDG 2768BE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG I/O processor detected a fault condition. Unknown hardware detected
177
28420A22 28423002
AJDGP01 AJDG301 28420A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 2842102E FRU List: FI01105 28421306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage 28422201 FRU List: USER FI01105 28422202 FRU List: FI00022 FI01105 IOP FI01104 BACKPLN 28421307 FRU List: AJDGP01 AJDG301 28421310 I/O processor resource not available I/O processor resource not available 28423000 FRU List: FI01101 IOP MA_BRDG 28423001 Not valid condition in I/O Processor Licensed InternalCode A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor detected a storage transfer error 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 28422200 FRU List: AJDGP01 I/O processor Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 28421317 I/O processor card error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 28423002 Addressed device failed to respond to selection
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following:
178
28423006 28423087
FI01105 STORIOA FI01140 FI01141 FI01106 28423006 FRU List: IOP ANYBUS FI01101 28423020 I/O processor detected a SCSI bus configuration error System bus error USER FI01107 STORIOA 28423023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28423080 FRU List: AJDGP01 28423081 System log entry only, no service action required. I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28423021 I/O processor detected a SCSI bus configuration error
28423084
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 28423087 I/O processor resource not available
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28423022 I/O processor detected a SCSI bus configuration error
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104
Chapter 3. 2xxx Reference Codes
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List:
179
28423100 28423122
28423100 I/O processor card detected interface error 28423109 I/O processor timed out a device command
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28423101 I/O processor card detected interface error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28423110 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28423102 I/O processor card detected interface error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28423120 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28423103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28423121 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28423122 I/O Processor detected that the bus is not operational
Servicer Response:
180
28423123 28423215
A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28423123 I/O Processor detected that the bus is not operational 28423150 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 28423151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28423136 FRU List: USER FI01105 28423140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 28423200 FRU List: FI01105 STORIOA IOP MEDIA 28423203 FRU List: FI01105 28423205 Disk sector read error Disk media format bad A tape/CD or disk device reported a failure
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 28423141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 28423142 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 28423215 Disk sector read error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 28423143 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.
181
28423250 28426082
28423250 Disk unit requires initialization before use. 28426070 FRU List: IOP 28426071 Storage unit detected a media problem FRU List: AJDGP01 28426072 FRU List: AJDGP01 IOP I/O processor card detected device error 28426073 FRU List: MEDIA FI01105 USER 28426075 FI01106 DEVTERM FI01140 28423401 FRU List: DEVBPLN 28423501 FRU List: AJDGP01 IOP 28423600 System log entry only, no service action required. System log entry only, no service action required. I/O processor Licensed Internal Code error Device backplane problem FRU List: AJDGP01 28426076 FRU List: MEDIA AJDGP01 FI01105 28426081 FRU List: AJDGP01 IOP 28426082 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor card detected media error I/O processor resource not available IPL device not ready I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error A permanent I/O processor failure occurred
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 28423300
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 28423400
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA
28423601
182
28426083 28428011
28426083 FRU List: AJDGP01 IOP 28426085 FRU List: AJDGP01 IOP MA_BRDG 28426200 FRU List: FCIOA OPT_CLN 28426201 FRU List: AJDGP01 28426602 FRU List: AJDGP01 28428000 A permanent IOP or cache adaptor card failure occurred. An I/O processor Licensed Internal Code error occurred. IOA LID is not valid Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28428010 A permanent cache adaptor card failure occurred. A permanent IOA hardware error occurred Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 28428007 A recoverable cache adaptor card error occurred. I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error STORIOA 28428004 FRU List: FI01141 STORIOA 28428005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply.
Servicer Response:
Servicer Response:
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 28428002 A permanent cache adaptor card failure occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28428011 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List:
Chapter 3. 2xxx Reference Codes
183
28428100 28428157
CACHE STORIOA 28428100 FRU List: AJDGP01 IOP ANYBRDG 28428130 IOA detected recoverable device bus error 28428151 FRU List: AJDGP01 STORIOA 28428155 FRU List: AJDGP01 STORIOA 28428156 FRU List: AJDGP01 STORIOA 28428157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error 28428146 FRU List: FI01105 28428150 FRU List: STORIOA A permanent I/O processor failure occurred Disk device detected recoverable error
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 28428131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 28428132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only. 28428133 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 28428140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 28428141 IOA detected recoverable device error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS
Servicer Response: No actionis required. This reference code is logged for information only. 28428145 FRU List: STORIOA A recoverable I/O processor error occurred.
184
28428200 28429012
28428200 FRU List: AJDGP01 IOP 28428300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error 28429002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28429008 I/O card does not support functions expected by devices
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01 28428301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 28429009 FRU List: SVCDOCS 28429010 Cache data associated with attached devices cannot befound. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101 AJDGP01 IOP 28428400 FRU List: AJDGP01 28429000 FRU List: FI01105 STORIOA 28429001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error
FRU List: SVCDOCS 28429011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 28429012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE
185
28429013 28429031
28429013 The IOP and attached cache adaptor card are not compatible. 28429026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 28429020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28429027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28429021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 28429028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28429022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 28429029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28429023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2842902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28429024 Array not functional due to present hardware configuration.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 28429030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28429025 Disk unit is not supported at its physical location.
186
28429040 28429092
28429040 Array protection temporarily suspended cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28429081 FRU List: FI01105 STORIOA 28429050 Required cache data cannot be located for a disk unit. 28429082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: No actionrequired. Protection will be automatically restarted. 28429041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 28429051 IOP cache data exists for a missing or failed device.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28429090 Disk unit has been modified after the last known status.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 28429052 Cache data exists for device that has been modified.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 28429053 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28429091 Incorrect hardware configuration change has been detected.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28429054 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28429092 Disk unit requires initialization before use.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you
187
2842B3B1 2842BE00
SVCDOCS 2842B3B1 FRU List: IOP 2842B3B2 FRU List: IOP 2842B3B3 FRU List: IOP 2842B3B4 FRU List: IOP 2842B3B5 FRU List: IOP 2842B3B6 FRU List: IOP 2842B3B7 FRU List: IOP 2842B3B8 FRU List: MA_BRDG IOP MA_BRDG 2842B3B9 FRU List: IOP A permanent I/O processor failure occurred 2842BE00 FRU List: AJDGP01 IOP FI01104 I/O processor detected a fault condition. Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 2842B3E0 FRU List: IOP MA_BRDG 2842B3E1 FRU List: IOP MA_BRDG 2842B410 FRU List: STORIOA 2842B411 FRU List: STORIOA 2842B412 Tape/CD or disk bus interface error occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. I/O processor detected a fault condition.
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 2842B935 FRU List: FI01101 AJDGP01 IOP Unknown hardware detected
188
2842FF3D 28432202
MA_BRDG 2842FF3D FRU List: STORIOA ANYBRDG 2842FF6D FRU List: IOP ANYBUS 28431317 28430A17 FRU List: IOP MA_BRDG AJDGP01 AJDG301 28430A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 2843102E FRU List: FI01105 28431306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage 28432201 FRU List: USER FI01105 28432202 FRU List: FI00022 FI01105 Removable media error during IPL Removable media error during IPL I/O processor detected a storage transfer error A permanent I/O processor failure occurred I/O processor card error I/O processor detected a recoverable system bus error. I/O adapter detected a recoverable error BACKPLN 28431307 FRU List: AJDGP01 AJDG301 28431310 I/O processor resource not available I/O processor resource not available
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 28432200 FRU List: AJDGP01 I/O processor Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104
189
28433000 28433081
28433000 FRU List: FI01101 IOP MA_BRDG 28433001 Not valid condition in I/O Processor Licensed InternalCode A permanent I/O processor failure occurred STORIOA 28433021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28433022 I/O processor detected a SCSI bus configuration error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 28433002 Addressed device failed to respond to selection
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA
FI01140 FI01141 FI01106 28433006 FRU List: IOP ANYBUS FI01101 28433020 I/O processor detected a SCSI bus configuration error System bus error 28433023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28433080 FRU List: AJDGP01 28433081 System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
190
28433084 28433110
28433084 I/O processor card or Licensed Internal Code error 28433102 I/O processor card detected interface error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140
FI01104 BACKPLN MA_BRDG 28433103 28433087 I/O processor resource not available Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 FI01140 IOACNFG BACKPLN FI01104 28433109 28433100 I/O processor card detected interface error I/O processor timed out a device command I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA
FI01140 BACKPLN BACKPLN FI01106 28433101 I/O processor card detected interface error 28433110 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA
191
28433120 28433200
FI01106 28433120 I/O Processor detected that the bus is not operational 28433141 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28433121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 28433142 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 28433143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28433122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 28433150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28433123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 28433151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28433136 FRU List: USER FI01105 The removable media device is assigned elsewhere
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 28433200 FRU List: FI01105 STORIOA A tape/CD or disk device reported a failure
28433140
IOP MEDIA
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.
192
28433203 28436076
28433203 FRU List: FI01105 28433205 Disk sector read error Disk media format bad 28433401 FRU List: DEVBPLN 28433501 FRU List: AJDGP01 IOP 28433600 System log entry only, no service action required. System log entry only, no service action required. A permanent I/O processor failure occurred I/O processor Licensed Internal Code error Device backplane problem
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 28433215 Disk sector read error
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 28433250 Disk unit requires initialization before use.
28433601
28436070 FRU List: IOP 28436071 FRU List: AJDGP01 Storage unit detected a media problem 28436072 FRU List: AJDGP01 IOP 28436073 I/O processor card detected device error FRU List: MEDIA FI01105 USER 28436075
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 28433300
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 28433400
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140
193
28436081 28438007
FI01105 28436081 FRU List: AJDGP01 IOP 28436082 FRU List: AJDGP01 IOP 28436083 FRU List: AJDGP01 IOP 28438004 28436085 FRU List: AJDGP01 IOP MA_BRDG 28436200 FRU List: FCIOA OPT_CLN 28436201 FRU List: AJDGP01 28436602 FRU List: AJDGP01 An I/O processor Licensed Internal Code error occurred. IOA LID is not valid 28438007 A recoverable cache adaptor card error occurred. A permanent IOA hardware error occurred 28438005 A recoverable IOP or cache adaptor card error occurred. I/O processor Licensed Internal Code error FRU List: FI01141 STORIOA Voltage drop detected on I/O processor 5 volt powersupply. I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error 28438000 A permanent IOP or cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 28438002 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
194
28438010 28438155
28438010 A permanent cache adaptor card failure occurred. 28438133 IOA detected recoverable device bus error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28438011 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 28438140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 28438141 IOA detected recoverable device error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28438100 FRU List: AJDGP01 IOP 28438130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: No actionis required. This reference code is logged for information only. 28438145 FRU List: STORIOA 28438146 FRU List: FI01105 28438150 FRU List: STORIOA ANYBRDG 28438151 FRU List: AJDGP01 STORIOA 28438155 FRU List: AJDGP01 STORIOA A permanent I/O processor failure occurred I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 28438131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 28438132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only.
195
28438156 28439009
28438156 FRU List: AJDGP01 STORIOA 28438157 I/O adapter card error FRU List: AJDGP01 28439000 FRU List: FI01105 STORIOA 28439001 I/O processor card detected device configuration error I/O processor card detected device error A permanent I/O processor failure occurred AJDGP01 IOP 28438400 I/O processor Licensed Internal Code error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 28438200 FRU List: AJDGP01 IOP 28438300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 28439002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28439008 I/O card does not support functions expected by devices
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 28439009 Call your next level of support for assistance
28438301
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101
196
28439010 28439029
28439010 Cache data associated with attached devices cannot befound. Perform IOPIP31. 28439023 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 28439011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28439024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 28439012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28439025 Disk unit is not supported at its physical location.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 28439013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 28439026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 28439020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28439027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28439021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 28439028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28439022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 28439029 Incorrect hardware configuration change has been detected.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS
Chapter 3. 2xxx Reference Codes
197
2843902F 28439082
2843902F Array addendum Product Activity Log entry 28439052 Cache data exists for device that has been modified.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 28439030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 28439053 IOP resources not available due to previous problems.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28439054 IOP resources not available due to previous problems.
Servicer Response: No actionrequired. Protection will be automatically restarted. 28439040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 28439041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28439081 I/O processor card detected device error
FRU List: AJDGP01 28439050 Required cache data cannot be located for a disk unit.
FRU List: FI01105 STORIOA 28439082 I/O processor card detected device error
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 28439051 IOP cache data exists for a missing or failed device.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS
198
28439090 2843B411
28439090 Disk unit has been modified after the last known status. 2843B3B5 FRU List: IOP 2843B3B6 FRU List: IOP Incorrect hardware configuration change has been detected. 2843B3B7 FRU List: IOP 2843B3B8 FRU List: MA_BRDG Disk unit requires initialization before use. IOP 2843B3B9 FRU List: IOP 2843B3E0 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred 2843B3E1 FRU List: IOP A permanent I/O processor failure occurred MA_BRDG 2843B410 FRU List: STORIOA 2843B411 FRU List: STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28439091
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28439092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 2843B3B1 FRU List: IOP 2843B3B2 FRU List: IOP 2843B3B3 FRU List: IOP 2843B3B4 FRU List: IOP A permanent I/O processor failure occurred A permanent I/O processor failure occurred
199
2843B412 28441317
2843B412 Tape/CD or disk bus interface error occurred AJDGP01 AJDG301 28440A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 2843B935 FRU List: FI01101 AJDGP01 IOP MA_BRDG 2843BE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG 2843FF3D FRU List: STORIOA ANYBRDG 2843FF6D FRU List: IOP ANYBUS 28441317 28440A17 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred I/O processor card error I/O processor detected a recoverable system bus error. I/O adapter detected a recoverable error I/O processor detected a fault condition. Unknown hardware detected 2844102E FRU List: FI01105 28441306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage I/O processor detected a storage transfer error
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 BACKPLN 28441307 FRU List: AJDGP01 AJDG301 28441310 I/O processor resource not available I/O processor resource not available
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following:
200
28442200 28443022
1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 28442200 FRU List: AJDGP01 28442201 FRU List: USER FI01105 28442202 FRU List: FI00022 FI01105 28443000 FRU List: FI01101 IOP MA_BRDG 28443001 Not valid condition in I/O Processor Licensed InternalCode A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error FI01105 STORIOA FI01140 FI01141 FI01106 28443006 FRU List: IOP ANYBUS FI01101 28443020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28443021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28443022 I/O processor detected a SCSI bus configuration error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 28443002 Addressed device failed to respond to selection
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List:
Chapter 3. 2xxx Reference Codes
201
28443023 28443103
USER FI01107 STORIOA 28443023 I/O processor detected a SCSI bus configuration error 28443100 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28443101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 28443080 FRU List: AJDGP01 28443081 System log entry only, no service action required. I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28443102 I/O processor card detected interface error
28443084
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 28443103 I/O processor card detected interface error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 28443087 I/O processor resource not available
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104
202
28443109 28443143
28443109 I/O processor timed out a device command A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28443123 I/O Processor detected that the bus is not operational
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28443110 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28443136 FRU List: USER FI01105 28443140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28443120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 28443141 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28443121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 28443142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 28443122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 28443143 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.
Servicer Response:
203
28443150 28443601
28443150 I/O processor detected a SCSI bus configuration error 28443250 Disk unit requires initialization before use.
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 28443151 I/O processor detected a SCSI bus configuration error
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 28443300 Storage unit detected a media problem
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 28443400 I/O processor card detected device error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 28443200 FRU List: FI01105 STORIOA IOP MEDIA 28443203 FRU List: FI01105 28443205 Disk sector read error Disk media format bad A tape/CD or disk device reported a failure
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 28443401 Device backplane problem
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 28443215 Disk sector read error
FRU List: DEVBPLN 28443501 FRU List: AJDGP01 IOP 28443600 System log entry only, no service action required. System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105
28443601
204
28446070 28448002
28446070 FRU List: IOP 28446071 FRU List: AJDGP01 28446072 FRU List: AJDGP01 IOP 28446073 FRU List: MEDIA FI01105 USER 28446075 FRU List: AJDGP01 28446076 FRU List: MEDIA AJDGP01 FI01105 28446081 FRU List: AJDGP01 IOP 28448002 28446082 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error A permanent cache adaptor card failure occurred. I/O processor Licensed Internal Code error Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE I/O processor card detected media error I/O processor resource not available 28446201 FRU List: AJDGP01 28446602 FRU List: AJDGP01 28448000 A permanent IOP or cache adaptor card failure occurred. An I/O processor Licensed Internal Code error occurred. IOA LID is not valid IPL device not ready I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error A permanent I/O processor failure occurred 28446083 FRU List: AJDGP01 IOP 28446085 FRU List: AJDGP01 IOP MA_BRDG 28446200 FRU List: FCIOA OPT_CLN A permanent IOA hardware error occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response:
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE
205
28448004 28448145
STORIOA 28448004 FRU List: FI01141 STORIOA 28448005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply. CACHE STORIOA 28448100 FRU List: AJDGP01 IOP 28448130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 28448007 A recoverable cache adaptor card error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 28448131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 28448132 IOA detected recoverable device bus error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28448010 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only. 28448133 IOA detected recoverable device bus error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 28448011 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 28448140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 28448141 IOA detected recoverable device error
Servicer Response: No actionis required. This reference code is logged for information only. 28448145 FRU List: STORIOA A recoverable I/O processor error occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List:
206
28448146 28449001
28448146 FRU List: FI01105 28448150 FRU List: STORIOA ANYBRDG 28448151 FRU List: AJDGP01 STORIOA 28448155 FRU List: AJDGP01 STORIOA 28448156 FRU List: AJDGP01 STORIOA 28448157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error 28448200 FRU List: AJDGP01 IOP 28448300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01 28448301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101 AJDGP01 IOP 28448400 FRU List: AJDGP01 28449000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS
28449001
207
28449002 28449025
28449002 I/O processor card detected device error 28449013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28449008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 28449020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28449021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 28449009 FRU List: SVCDOCS 28449010 Cache data associated with attached devices cannot befound. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 28449022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28449023 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 28449011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28449024 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 28449012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28449025 Disk unit is not supported at its physical location.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE
208
28449026 28449054
28449026 Array not functional due to present hardware configuration. 28449040 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 28449027 Array not functional due to present hardware configuration.
Servicer Response: No actionrequired. Protection will be automatically restarted. 28449041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 28449028 Incorrect hardware configuration change has been detected.
FRU List: AJDGP01 28449050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 28449051 IOP cache data exists for a missing or failed device.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 28449029 Incorrect hardware configuration change has been detected.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 28449052 Cache data exists for device that has been modified.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 2844902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 28449053 IOP resources not available due to previous problems.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 28449030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28449054 IOP resources not available due to previous problems.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you
Chapter 3. 2xxx Reference Codes
209
28449081 2844B3B9
cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 28449081 FRU List: FI01105 STORIOA 28449082 I/O processor card detected device error I/O processor card detected device error SVCDOCS 2844B3B1 FRU List: IOP 2844B3B2 FRU List: IOP 2844B3B3 FRU List: IOP 2844B3B4 FRU List: IOP 2844B3B5 FRU List: IOP 2844B3B6 FRU List: IOP 2844B3B7 FRU List: IOP 2844B3B8 FRU List: MA_BRDG IOP 2844B3B9 Disk unit requires initialization before use. FRU List: IOP A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 28449090 Disk unit has been modified after the last known status.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28449091 Incorrect hardware configuration change has been detected.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 28449092
210
2844B3E0 284B1306
2844B3E0 FRU List: IOP MA_BRDG 2844B3E1 FRU List: IOP MA_BRDG 2844B410 FRU List: STORIOA 2844B411 FRU List: STORIOA 2844B412 Tape/CD or disk bus interface error occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. I/O processor detected a fault condition. MA_BRDG 2844FF3D FRU List: STORIOA ANYBRDG 2844FF6D FRU List: IOP ANYBUS 284B0A17 FRU List: IOP MA_BRDG AJDGP01 AJDG301 284B0A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG Unknown hardware detected 284B102E FRU List: FI01105 284B1306 IOP MA_BRDG 2844BE00 FRU List: AJDGP01 IOP FI01104 FI01104
Chapter 3. 2xxx Reference Codes
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 2844B935 FRU List: FI01101 AJDGP01
Servicer Response: A microprocessor exception occurred on the I/O processor. I/O processor detected a fault condition. FRU List: AJDGP01 IOP
211
284B1307 284B3020
BACKPLN 284B1307 FRU List: AJDGP01 AJDG301 MA_BRDG 284B1310 I/O processor resource not available 284B3001 Not valid condition in I/O Processor Licensed InternalCode I/O processor resource not available 284B3000 FRU List: FI01101 IOP A permanent I/O processor failure occurred
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 284B1317 I/O processor card error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 284B3002 Addressed device failed to respond to selection
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 284B2200 FRU List: AJDGP01 284B2201 FRU List: USER FI01105 284B2202 FRU List: FI00022 FI01105 Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 FI01141 FI01106 284B3006 FRU List: IOP ANYBUS FI01101 284B3020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
212
284B3021 284B3101
STORIOA 284B3021 I/O processor detected a SCSI bus configuration error 284B3084 I/O processor card or Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 284B3022 I/O processor detected a SCSI bus configuration error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 284B3087 I/O processor resource not available
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104 284B3100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 284B3023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 284B3101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 284B3080 FRU List: AJDGP01 284B3081 System log entry only, no service action required. I/O processor Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN
213
284B3102 284B3140
284B3102 I/O processor card detected interface error FI01106 284B3120 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 284B3103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 284B3121 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 284B3109 I/O processor timed out a device command
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 284B3122 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 284B3123 I/O Processor detected that the bus is not operational
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 284B3110 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 284B3136 FRU List: USER FI01105 284B3140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational.
214
284B3141 284B3400
284B3141 I/O Processor detected that the bus is now operational 284B3203 FRU List: FI01105 284B3205 Disk sector read error Disk media format bad
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 284B3142 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 284B3215 Disk sector read error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 284B3143 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 284B3250 Disk unit requires initialization before use.
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 284B3150 I/O processor detected a SCSI bus configuration error
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 284B3300 Storage unit detected a media problem
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 284B3151 I/O processor detected a SCSI bus configuration error
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 284B3400 A tape/CD or disk device reported a failure I/O processor card detected device error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 284B3200 FRU List: FI01105 STORIOA IOP MEDIA
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140
215
284B3401 284B6602
284B3401 FRU List: DEVBPLN 284B3501 FRU List: AJDGP01 IOP 284B3600 System log entry only, no service action required. System log entry only, no service action required. A permanent I/O processor failure occurred I/O processor Licensed Internal Code error Device backplane problem FI01105 284B6081 FRU List: AJDGP01 IOP 284B6082 FRU List: AJDGP01 IOP 284B3601 284B6083 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error 284B6085 FRU List: AJDGP01 I/O processor Licensed Internal Code error IOP MA_BRDG 284B6200 FRU List: FCIOA OPT_CLN 284B6201 FRU List: AJDGP01 I/O processor resource not available 284B6602 FRU List: AJDGP01 I/O processor card detected media error An I/O processor Licensed Internal Code error occurred. IOA LID is not valid A permanent IOA hardware error occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error
284B6070 FRU List: IOP 284B6071 FRU List: AJDGP01 284B6072 FRU List: AJDGP01 IOP 284B6073 FRU List: MEDIA FI01105 USER 284B6075 FRU List: AJDGP01 284B6076 FRU List: MEDIA AJDGP01
216
284B8000 284B8132
284B8000 A permanent IOP or cache adaptor card failure occurred. 284B8010 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 284B8002 A permanent cache adaptor card failure occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 284B8011 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 284B8004 FRU List: FI01141 STORIOA 284B8005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 284B8100 FRU List: AJDGP01 IOP 284B8130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 284B8007 A recoverable cache adaptor card error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 284B8131 IOA detected recoverable device bus error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 284B8132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only.
217
284B8133 284B8301
284B8133 IOA detected recoverable device bus error 284B8156 FRU List: AJDGP01 STORIOA 284B8140 IOA detected recoverable device bus error 284B8157 I/O adapter card error A permanent I/O processor failure occurred
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only.
Servicer Response: No actionis required. This reference code is logged for information only. 284B8141 IOA detected recoverable device error
Servicer Response: No actionis required. This reference code is logged for information only. 284B8145 FRU List: STORIOA 284B8146 FRU List: FI01105 284B8150 FRU List: STORIOA ANYBRDG A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 284B8200 FRU List: AJDGP01 IOP 284B8300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
284B8151 FRU List: AJDGP01 STORIOA 284B8155 FRU List: AJDGP01 STORIOA
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA
IOP AJDGP01 284B8301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101
218
284B8400 284B9022
AJDGP01 IOP 284B8400 FRU List: AJDGP01 284B9000 FRU List: FI01105 STORIOA 284B9001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error FRU List: SVCDOCS 284B9011 Cache data belongs to devices other than those attached 284B9010 Cache data associated with attached devices cannot befound . Perform IOPIP31.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 284B9012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 284B9002 I/O processor card detected device error
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 284B9013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 284B9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 284B9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 284B9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 284B9009 FRU List: SVCDOCS Call your next level of support for assistance
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 284B9022 Array not functional due to present hardware configuration.
219
284B9023 284B9051
284B9023 Array not functional due to present hardware configuration. 284B902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 284B9024 Array not functional due to present hardware configuration.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 284B9030 Array no longer protected due to missing or failed diskunit. Perform IOPIP21.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 284B9025 Disk unit is not supported at its physical location. FRU List: SVCDOCS 284B9031
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 284B9026 Array not functional due to present hardware configuration.
Servicer Response: No actionrequired. Protection will be automatically restarted. 284B9040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 284B9041 Background array parity check detected and correctederrors. Call your next level of support to report the problem.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 284B9027 Array not functional due to present hardware configuration.
FRU List: AJDGP01 284B9050 Required cache data cannot be located for a disk unit.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 284B9028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 284B9051 IOP cache data exists for a missing or failed device.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 284B9029 Incorrect hardware configuration change has been detected.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS
Servicer Response: Contact your next level of support. FRU List: SVCDOCS
220
284B9052 284BB3B4
284B9052 Cache data exists for device that has been modified. 284B9090 Disk unit has been modified after the last known status.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 284B9053 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 284B9091 Incorrect hardware configuration change has been detected.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 284B9054 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 284B9092 Disk unit requires initialization before use.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 284B9081 FRU List: FI01105 STORIOA 284B9082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 284BB3B1 FRU List: IOP 284BB3B2 FRU List: IOP 284BB3B3 FRU List: IOP 284BB3B4 A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
221
284BB3B5 284BFF6D
284BB3B5 FRU List: IOP 284BB3B6 FRU List: IOP 284BB3B7 FRU List: IOP 284BB3B8 FRU List: MA_BRDG IOP 284BB3B9 FRU List: IOP 284BB3E0 FRU List: IOP MA_BRDG 284BFF3D 284BB3E1 FRU List: IOP MA_BRDG 284BFF6D 284BB410 FRU List: STORIOA 284BB411 FRU List: STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred FRU List: IOP ANYBUS I/O processor detected a recoverable system bus error. I/O processor detected a fault condition. FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 284BB412 Tape/CD or disk bus interface error occurred
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 284BB935 FRU List: FI01101 AJDGP01 IOP MA_BRDG 284BBE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG I/O processor detected a fault condition. Unknown hardware detected
222
2750B980 2761B982
223
2761B983 27658150
2761B983 FRU List: FI00719 I/O adapter hardware error detected FI00730
Servicer Response: Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 27653100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 27653120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 27653140 I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 27658130 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 27658140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 27658141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 27658145 FRU List: FCIOA OPT_CLN 27658146 Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 27653400 FRU List: FCDEV FCINTF I/O processor card detected device error
224
27658151 27663140
FRU List: FCIOA ANYBRDG OPT_CLN 2765FF3D 27658151 FRU List: AJDGP01 FCIOA IOP OPT_CLN 27658155 FRU List: AJDGP01 FCIOA OPT_CLN 27658156 FRU List: AJDGP01 FCIOA OPT_CLN 27659091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error FRU List: FCIOA ANYBRDG OPT_CLN 27663020 I/O processor detected a configuration error Recovered IOA error processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS
Servicer Response: Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 27663100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 27663120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 27663140 I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 27659092 Incorrect hardware configuration change has been detected.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational.
225
27663400 27669092
27663400 FRU List: FCDEV FCINTF ANYFC FCIOA FCIOA IOP OPT_CLN OPT_CLN 276634FF Format in progress 27668155 FRU List: AJDGP01 FCIOA 27668130 Recovered Fibre Channel interface error OPT_CLN 27668156 FRU List: AJDGP01 FCIOA OPT_CLN 27668141 IOA detected recoverable device error 27669091 Incorrect hardware configuration change has been detected. Servicer Response: No actionrequired. This reference code is logged for information only. 27668145 FRU List: FCIOA OPT_CLN 27668146 FRU List: FCDEV 27668150 FRU List: FCIOA ANYBRDG A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred. A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor card detected device error OPT_CLN 27668151 FRU List: AJDGP01 I/O processor Licensed Internal Code error
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only.
Servicer Response: No actionrequired. This reference code is logged for information only. 27668140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 27669092 Incorrect hardware configuration change has been detected.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS
226
2766FF3D 27878151
2766FF3D FRU List: FCIOA ANYBRDG OPT_CLN 27873020 I/O processor detected a configuration error Recovered IOA error FCIOA OPT_CLN 278734FF Format in progress
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 27878130 Recovered Fibre Channel interface error
Servicer Response: Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 27873100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 27873120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 27873140 I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 27878140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 27878141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 27878145 FRU List: FCIOA OPT_CLN 27878146 FRU List: FCDEV 27878150 FRU List: FCIOA ANYBRDG OPT_CLN 27878151 FRU List: AJDGP01 FCIOA
Chapter 3. 2xxx Reference Codes
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 27873400 FRU List: FCDEV FCINTF ANYFC I/O processor card detected device error
227
27878155 280D3400
IOP OPT_CLN 27878155 FRU List: AJDGP01 FCIOA OPT_CLN 27878156 FRU List: AJDGP01 FCIOA OPT_CLN 27879091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred FRU List: FCINTF ANYFC FCIOA OPT_CLN 280D3120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 280D3140 I/O Processor detected that a port is now operational I/O processor detected a port failure A permanent I/O processor failure occurred 280D3020 I/O processor detected a configuration error
Servicer Response: Either too many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 280D3100 I/O processor card detected interface error
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 27879092 Incorrect hardware configuration change has been detected.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 2787FF3D FRU List: FCIOA ANYBRDG OPT_CLN Recovered IOA error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 280D3400 FRU List: FCDEV FCINTF ANYFC FCIOA OPT_CLN I/O processor card detected device error
228
280D34FF 280E3020
280D34FF Format in progress 280D8155 FRU List: AJDGP01 FCIOA OPT_CLN 280D8156 FRU List: AJDGP01 FCIOA OPT_CLN 280D9091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 280D8130 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 280D8140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 280D8141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 280D8145 FRU List: FCIOA OPT_CLN A recoverable I/O processor error occurred.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 280D9092 Incorrect hardware configuration change has been detected.
280D8146 FRU List: FCDEV 280D8150 FRU List: FCIOA ANYBRDG OPT_CLN 280D8151 FRU List: AJDGP01 FCIOA IOP OPT_CLN
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 280DFF3D FRU List: FCIOA Recovered IOA error
Servicer Response:
229
280E3100 280E8155
Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 280E3100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 280E3120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 280E3140 I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error 280E8130 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 280E8140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 280E8141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 280E8145 FRU List: FCIOA OPT_CLN 280E8146 FRU List: FCDEV 280E8150 FRU List: FCIOA ANYBRDG A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 280E3400 FRU List: FCDEV FCINTF ANYFC FCIOA OPT_CLN 280E34FF Format in progress I/O processor card detected device error
OPT_CLN 280E8151 FRU List: AJDGP01 FCIOA IOP OPT_CLN 280E8155 FRU List: AJDGP01 FCIOA A permanent I/O processor failure occurred I/O processor Licensed Internal Code error
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only.
230
280E8156 57048130
OPT_CLN 280E8156 FRU List: AJDGP01 FCIOA OPT_CLN 280E9091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred 57043100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 57043120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 57043140 280E9092 Incorrect hardware configuration change has been detected. I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 280EFF3D FRU List: FCIOA ANYBRDG OPT_CLN Recovered IOA error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 57043400 FRU List: FCDEV FCINTF ANYFC FCIOA OPT_CLN 570434FF Format in progress I/O processor card detected device error
57043020
Servicer Response: Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 57048130 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only.
231
57048140 5704FF3D
57048140 Recovered Fibre Channel interface error 57048156 FRU List: AJDGP01 FCIOA OPT_CLN 57049091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred
Servicer Response: No actionrequired. This reference code is logged for information only. 57048141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 57048145 FRU List: FCIOA OPT_CLN 57048146 FRU List: FCDEV 57048150 FRU List: FCIOA ANYBRDG OPT_CLN 57048151 FRU List: AJDGP01 FCIOA I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 57049092 Incorrect hardware configuration change has been detected.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 5704FF3D FRU List: FCIOA ANYBRDG OPT_CLN Recovered IOA error
IOP OPT_CLN 57048155 FRU List: AJDGP01 FCIOA OPT_CLN A permanent I/O processor failure occurred
232
2771B904 28030001
233
28030002 281xB910
Servicer Response: Set the time and date. Note: This isnormally an informational message. If the problem persists, replace the system backplane. FRU List: SYSBKP2 28030002 Bad time/date values 2803000A The hypervisor function to get or set the time-of-day (TOD) reported an error. 2. Refer to the actions under 28030001. 28030005 Real-time-clock battery error
Servicer Response: Set the time anddate. Note: This is normally an informational message. If the problem persists, replace the system backplane. FRU List: SYSBKP2 28030003 Real-time-clock not updating: not correctable.
Servicer Response: Errors reported against the real timeclock might be caused by low battery voltage or (more rarely) power outages that occur during normal system usage. These errors are warnings that the real time clock data content needs to be reestablished. Unless the error is persistent, these errors do not require any FRU replacement. When one of these errors occurs, the system loses time and date information. Reset the server time and date through the installed operating system. If the error is persistent, do the following:
Servicer Response: Replace the system backplane. FRU List: SYSBKP2 28030004 Real-time-clock operating mode parameters (for example,data mode) changed.
1. Check for system firmware updates, and apply if available. 2. Replace the system battery. 3. Replace the system backplane. FRU List: SYSBKP2
234
2838B904 283C1511
2. Look at the last 8 characters of the top 16 character line of function 12 (word 3). These 8 characters are the direct select address of the card (BBBBCcbb). The unit address portion of the card address is characters 1 through 8 of the bottom 16 character line of function 11 (Word 4). Card locations can be found using the 16 character address.
2838B904 FRU List: AJDGP01 FI00719 2838B930 FRU List: AJDGP01 FI00718 FI00719 2838B931 FRU List: FI00719 FI00718 AJDGP01 MA_BRDG 2838B933 FRU List: FI00719 AJDGP01 Incompatible hardware detected. I/O adapter hardware error detected I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. 2849B904 FRU List: AJDGP01 FI00719 2849B930 FRU List: AJDGP01 FI00718 FI00719 2849B931 FRU List: FI00719 FI00718 AJDGP01 MA_BRDG 2849B933 FRU List: FI00719 AJDGP01 Incompatible hardware detected. I/O adapter hardware error detected I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed.
(283C, 283D, 283F, 28B9, 28CB, 28CC, 28D2, 28DB, 28DF) Device backplane reference codes
Device backplane reference codes If the error is reported on the control panel, the reference code is characters 1 through 8 of the top 16 character line of function 11. If the error is reported on the console, the reference code is the 8 rightmost characters of word 1. Note: The 673x is a read cache. Perform all actions required for 673x as a disk drive and logic card except where separate 673x cache instructions are provided.
283C1511 FRU List: DISKPWR A non-fatal error occurred on power supply 1 DISKFAN FI01106 DEVBPLN
235
283C1515 283D1511
283C1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283C7621 283C1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283C1525 FRU List: DISKPWR DISKFAN FI01106 283C8401 DEVBPLN 283C3002 FRU List: DEVBPLN STORIOA FI01140 FI01106 283C3109 FRU List: DEVBPLN STORIOA FI01140 FI01106 FRU List: DISKPWR DISKFAN I/O adapter timed out a device backplane command. 283CFFF4 FRU List: DEVBPLN STORIOA FI01140 FI01106 283D1511 A non-fatal error occurred on power supply 1 Addressed device backplane failed to respond to selection. FRU List: DEVBPLN 283C8404 System log entry only, no service action required Device backplane problem Removable media power fault A fatal error occurred on power supply 2 A non-fatal error occurred on power supply 2 FRU List: DISKFAN 283C7624 FRU List: DISKFAN 283C7631 FRU List: DISKFAN 283C7634 FRU List: DISKFAN A fatal error occurred on fan 3 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on power supply 1 283C7611 FRU List: DISKFAN 283C7614 FRU List: DISKFAN A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1
236
283D1515 283DFFF4
FI01106 DEVBPLN 283D1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283D7621 283D1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283D1525 FRU List: DISKPWR DISKFAN FI01106 283D8401 DEVBPLN 283D3002 FRU List: DEVBPLN STORIOA FI01140 FI01106 283D3109 FRU List: DEVBPLN STORIOA
Chapter 3. 2xxx Reference Codes
FI01140 FI01106 A fatal error occurred on power supply 1 283D7611 FRU List: DISKFAN 283D7614 FRU List: DISKFAN A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1
FRU List: DISKFAN 283D7624 FRU List: DISKFAN 283D7631 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2
FRU List: DISKFAN 283D7634 FRU List: DISKFAN Removable media power fault A fatal error occurred on fan 3
FRU List: DEVBPLN Addressed device backplane failed to respond to selection 283D8404 System log entry only, no service action required Device backplane problem
283DFFF4 FRU List: DEVBPLN STORIOA I/O adapter timed out a device backplane command FI01140 FI01106
237
283F1511 283FFFF4
283F1511 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283F1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283F7621 283F1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 283F1525 FRU List: DISKPWR DISKFAN FI01106 283F8401 DEVBPLN 283F3002 FRU List: DEVBPLN STORIOA FI01140 FI01106 283FFFF4 FRU List: DEVBPLN STORIOA Addressed device backplane failed to respond to selection FRU List: DEVBPLN 283F8404 System log entry only, no service action required Device backplane problem Removable media power fault A fatal error occurred on power supply 2 A non-fatal error occurred on power supply 2 FRU List: DISKFAN 283F7624 FRU List: DISKFAN 283F7631 FRU List: DISKFAN 283F7634 FRU List: DISKFAN A fatal error occurred on fan 3 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on power supply 1 A non-fatal error occurred on power supply 1 283F3109 FRU List: DEVBPLN STORIOA FI01140 FI01106 283F7611 FRU List: DISKFAN 283F7614 FRU List: DISKFAN A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1 I/O adapter timed out a device backplane command
238
28B91511 28B98404
FI01140 FI01106 28B91511 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28B91515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28B97621 28B91521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28B91525 FRU List: DISKPWR DISKFAN FI01106 28B98401 DEVBPLN 28B93002 FRU List: DEVBPLN STORIOA
Chapter 3. 2xxx Reference Codes
FI01140 FI01106 A non-fatal error occurred on power supply 1 28B93109 FRU List: DEVBPLN STORIOA FI01140 FI01106 A fatal error occurred on power supply 1 28B97611 FRU List: DISKFAN 28B97614 FRU List: DISKFAN A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1 I/O adapter timed out a device backplane command
FRU List: DISKFAN 28B97624 FRU List: DISKFAN 28B97631 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2
FRU List: DISKFAN 28B97634 FRU List: DISKFAN Removable media power fault A fatal error occurred on fan 3
FRU List: DEVBPLN Addressed device backplane failed to respond to selection 28B98404 System log entry only, no service action required
239
28B9FFF4 28CB7634
28B9FFF4 FRU List: DEVBPLN STORIOA STORIOA FI01140 FI01140 FI01106 FI01106 28CB1511 FRU List: DISKPWR DISKFAN STORIOA FI01106 FI01140 DEVBPLN FI01106 28CB1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28CB1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28CB7631 28CB1525 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN A fatal error occurred on power supply 2 FRU List: DISKFAN 28CB7634 FRU List: DISKFAN A fatal error occurred on fan 3 A fatal error occurred on redundant fan 3 A non-fatal error occurred on power supply 2 28CB7614 FRU List: DISKFAN 28CB7621 FRU List: DISKFAN 28CB7624 FRU List: DISKFAN A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 A fatal error occurred on power supply 1 28CB7611 FRU List: DISKFAN A fatal error occurred on redundant fan 1 A non-fatal error occurred on power supply 1 28CB3109 FRU List: DEVBPLN I/O adapter timed out a device backplane command Device backplane problem 28CB3002 FRU List: DEVBPLN Addressed device backplane failed to respond to selection
240
28CB8401 28CC7624
28CB8401 FRU List: DEVBPLN 28CB8404 System log entry only, no service action required Device backplane problem DEVBPLN 28CC3002 STORIOA FI01140 FI01106 28CC1511 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28CC1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28CC7614 28CC1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN A non-fatal error occurred on power supply 2 FRU List: DISKFAN 28CC7621 FRU List: DISKFAN 28CC7624 FRU List: DISKFAN A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 FRU List: DISKFAN A fatal error occurred on power supply 1 FRU List: DEVBPLN STORIOA FI01140 FI01106 28CC7611 A fatal error occurred on redundant fan 1 A non-fatal error occurred on power supply 1 FRU List: DEVBPLN STORIOA FI01140 FI01106 28CC3109 I/O adapter timed out a device backplane command Addressed device backplane failed to respond to selection Removable media power fault 28CC1525 FRU List: DISKPWR DISKFAN FI01106 28CBFFF4 FRU List: DEVBPLN A fatal error occurred on power supply 2
241
28CC7631 28D27614
28CC7631 FRU List: DISKFAN 28CC7634 FRU List: DISKFAN 28CC8401 FRU List: DEVBPLN 28CC8404 System log entry only, no service action required Device backplane problem Removable media power fault 28D21525 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28D23002 FRU List: DEVBPLN STORIOA FI01140 FI01106 28D23109 FRU List: DEVBPLN STORIOA FI01140 FI01106 28D27611 FRU List: DISKFAN 28D27614 FRU List: DISKFAN A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1 I/O adapter timed out a device backplane command Addressed device backplane failed to respond to selection A fatal error occurred on power supply 2 A fatal error occurred on fan 3 A fatal error occurred on redundant fan 3 28D21521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN A non-fatal error occurred on power supply 2
28CCFFF4 FRU List: DEVBPLN STORIOA FI01140 FI01106 28D21511 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28D21515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN
242
28D27621 28DB3109
28D27621 FRU List: DISKFAN 28D27624 FRU List: DISKFAN 28D27631 FRU List: DISKFAN 28D27634 FRU List: DISKFAN 28D28401 FRU List: DEVBPLN 28D28404 System log entry only, no service action required Device backplane problem Removable media power fault A fatal error occurred on fan 3 28DB1525 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28DB3002 FRU List: DEVBPLN STORIOA FI01140 FI01140 FI01106 FI01106 28DB1511 FRU List: DISKPWR DISKFAN STORIOA FI01106 FI01140 DEVBPLN FI01106 28DB1515 FRU List: DISKPWR A fatal error occurred on power supply 1 A non-fatal error occurred on power supply 1 28DB3109 FRU List: DEVBPLN I/O adapter timed out a device backplane command Addressed device backplane failed to respond to selection A fatal error occurred on power supply 2 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 DISKFAN FI01106 DEVBPLN 28DB1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN A non-fatal error occurred on power supply 2
243
28DB7611 28DF3109
28DB7611 FRU List: DISKFAN 28DB7614 FRU List: DISKFAN 28DB7621 FRU List: DISKFAN 28DB7624 FRU List: DISKFAN 28DB7631 FRU List: DISKFAN 28DB7634 FRU List: DISKFAN 28DB8401 FRU List: DEVBPLN 28DB8404 System log entry only, no service action required Device backplane problem FRU List: DEVBPLN STORIOA FI01140 FI01106 A non-fatal error occurred on power supply 1 28DF3109 FRU List: DEVBPLN STORIOA I/O adapter timed out a device backplane command Removable media power fault DISKFAN FI01106 DEVBPLN 28DF3002 28DBFFF4 FRU List: DEVBPLN STORIOA FI01140 FI01106 28DF1511 FRU List: DISKPWR DISKFAN Addressed device backplane failed to respond to selection A fatal error occurred on fan 3 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1 FI01106 DEVBPLN 28DF1515 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28DF1521 FRU List: DISKPWR DISKFAN FI01106 DEVBPLN 28DF1525 FRU List: DISKPWR A fatal error occurred on power supply 2 A non-fatal error occurred on power supply 2 A fatal error occurred on power supply 1
244
28DF7611 28473000
FI01140 FI01106 28DF7634 28DF7611 FRU List: DISKFAN 28DF7614 FRU List: DISKFAN 28DF7621 FRU List: DISKFAN 28DF7624 FRU List: DISKFAN 28DF7631 A fatal error occurred on redundant fan 3 A fatal error occurred on fan 2 A fatal error occurred on redundant fan 2 A fatal error occurred on fan 1 A fatal error occurred on redundant fan 1 FRU List: DISKFAN 28DF8401 FRU List: DEVBPLN 28DF8404 System log entry only, no service action required Device backplane problem Removable media power fault A fatal error occurred on fan 3 FRU List: DISKFAN
MA_BRDG 28471307 FRU List: AJDGP01 I/O processor resource not available
28471310
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 28473000 A permanent I/O processor failure occurred
245
28473001 28473120
MA_BRDG OPT_CLN 28473001 Not valid condition in I/O Processor Licensed Internal Code FCIOA MA_BRDG OPT_CLN 28473087 I/O processor resource not available
Servicer Response: The Licensed Internal Code found a condition that should not have occurred. FRU List: IOP AJDGP01
Servicer Response: The Licensed Internal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301
28473002 FRU List: FCPORT FCDEV FCIOA FCINTF OPT_CLN 28473006 FRU List: IOP ANYBUS FCIOA OPT_CLN
FCIOA OPT_CLN 28473100 FRU List: FCINTF ANYFC I/O processor card detected interface error
FCIOA OPT_CLN 28473109 FRU List: FCDEV FCINTF I/O processor timed out a device command
System log entry only, no service action required I/O processor card or Licensed Internal Code error
28473084
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP
246
28473200 28478150
28473200 FRU List: FCDEV FCIOA IOP IOP OPT_CLN 28473501 FRU List: AJDGP01 IOP 28476070 FRU List: IOP 28476071 FRU List: AJDGP01 28476072 FRU List: AJDGP01 IOP 28476075 FRU List: AJDGP01 28476076 FRU List: AJDG301 AJDGP01 FCDEV 28476081 FRU List: AJDGP01 IOP
Chapter 3. 2xxx Reference Codes
28476083 FRU List: AJDGP01 IOP 28476085 FRU List: AJDGP01 IOP MA_BRDG I/O processor Licensed Internal Code error 28476200 FRU List: FCIOA I/O processor Licensed Internal Code error OPT_CLN 28476201 FRU List: AJDGP01 I/O processor resource not available 28478100 FRU List: AJDGP01 I/O processor card detected media error IOP 28478150 FRU List: FCIOA I/O processor Licensed Internal Code error ANYBRDG OPT_CLN
247
28478155 2847B3E0
28478155 FRU List: AJDGP01 FCIOA OPT_CLN 28478156 FRU List: AJDGP01 FCIOA OPT_CLN 28478200 FRU List: AJDGP01 IOP 28478300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error A permanent I/O processor failure occurred FRU List: IOP 2847B3B3 FRU List: IOP 2847B3B4 FRU List: IOP 2847B3B5 FRU List: IOP 2847B3B6 FRU List: IOP 2847B3B7 FRU List: IOP 2847B3B8 Not valid condition in I/O Processor Licensed Internal Code FRU List: MA_BRDG IOP 2847B3E0 FRU List: IOP MA_BRDG I/O processor detected a fault condition. Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 2847B3B1 FRU List: IOP 2847B3B2 A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: FCIOA IOP AJDGP01 OPT_CLN 28478301
Servicer Response: The Licensed Internal Code found a condition that should not have occurred. FRU List: FCIOA AJDGP01 IOP OPT_CLN
248
2847B3E1 28753002
2847B3E1 FRU List: IOP MA_BRDG 2847B935 FRU List: FCIOA AJDGP01 OPT_CLN IOP MA_BRDG Unknown hardware detected I/O processor detected a fault condition. OPT_CLN 2847BE00 FRU List: AJDGP01 IOP FCIOA MA_BRDG I/O processor detected a fault condition.
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
DEVBPLN
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
DEVBPLN
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU.
Chapter 3. 2xxx Reference Codes
249
28753109 28761511
SASCABL 28757644 A fatal error occurred on fan 4
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
28758401
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DEVBPLN 28758404 System log entry only, no service action required Device backplane problem
SASCABL
STORIOA
2875FFF4
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
SASCABL
STORIOA 28757624 A fatal error occurred on fan 2 DEVBPLN 28761511 A non-fatal error occurred on power supply
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 28757634 A fatal error occurred on fan 3
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
DEVBPLN
SASEXP
250
28761515 28767634
28761515 A non-fatal error occurred on power supply 1
SASCABL
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
STORIOA
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
SASCABL
STORIOA
DEVBPLN DEVBPLN 28767614 SASEXP 28761525 A fatal error occurred on power supply 2 A fatal error occurred on fan 1 Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 28767624 A fatal error occurred on fan 2
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List:
DEVBPLN DISKFAN SASEXP 28763002 Addressed device backplane failed to respond to selection 28767634 A fatal error occurred on fan 3
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
251
28767644 293C3002
28767644 A fatal error occurred on fan 4 293C1515 A non-fatal error occurred on power supply 1
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
28768401
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DEVBPLN 28768404 System log entry only, no service action required Device backplane problem
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
2876FFF4
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
DEVBPLN
SASCABL
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: A non-fatal error occurred on power supply DISKPWR
DEVBPLN 293C1511
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
DEVBPLN
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
SASEXP
252
293C3109 293D1511
293C7644 A fatal error occurred on fan 4
SASCABL
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List:
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DEVBPLN 293C8404 System log entry only, no service action required Device backplane problem
SASCABL
STORIOA
293CFFF4
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 293C7624 A fatal error occurred on fan 2
SASCABL
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 293C7634 A fatal error occurred on fan 3
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
DEVBPLN
SASEXP
253
293D1515 293D7634
293D1515 A non-fatal error occurred on power supply 1
SASCABL
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
STORIOA
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
SASCABL
STORIOA
DEVBPLN DEVBPLN 293D7614 SASEXP 293D1525 A fatal error occurred on power supply 2 A fatal error occurred on fan 1 Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 293D7624 A fatal error occurred on fan 2
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List:
DEVBPLN DISKFAN SASEXP 293D3002 Addressed device backplane failed to respond to selection 293D7634 A fatal error occurred on fan 3
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
254
293D7644 28901310
293D7644 A fatal error occurred on fan 4 293DFFF4 Device backplane problem
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 293D8401 Removable media power fault
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
SASCABL
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DEVBPLN 293D8404 System log entry only, no service action required
STORIOA
DEVBPLN
Servicer Response: The INS processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. FRU List:
Chapter 3. 2xxx Reference Codes
255
28903000 28906202
IOP AJDGP01 28903000 FRU List: IOP AJDGP01 28903001 FRU List: IOP AJDGP01 28903006 FRU List: IOP ANYBUS 28903080 FRU List: AJDGP01 28903081 28903084 FRU List: AJDGP01 IOP IOA MA_BRDG 28903087 FRU List: AJDGP01 AJDG301 NTUSER IOA IOP I/O adapter resource not available. FRU List: IOP AJDGP01 28906202 FRU List: AJDGP01 I/O processor Licensed Internal Code error I/O adapter error; logged only. An I/O adapter failure occurred. I/O adapter Licensed Internal Code failed. An I/O adapter failure occurred. I/O adapter Licensed Internal Code failed. An I/O adapter failure occurred. 28906071 FRU List: AJDGP01 28906072 FRU List: AJDGP01 IOP 28906075 FRU List: AJDGP01 28906083 FRU List: AJDGP01 IOP 28906085 FRU List: AJDGP01 IOP MA_BRDG 28906201 A permanent I/O processor failure occurred I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. I/O adapter resource not available. I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. 28906070 FRU List: IOP An I/O adapter failure occurred.
256
28906210 28906532
28906210 FRU List: AJDGP01 28906221 FRU List: AJDG301 28906222 FRU List: AJDGP01 IOP 28906223 FRU List: IOP AJDGP01 28906224 FRU List: DISKIMG AJDGP01 IOP MEMORY 28906225 FRU List: AJDGP01 AJDG301 IOP 28906226 FRU List: AJDG301 AS4NTDD I/O processor card detected device error A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor resource not available I/O processor Licensed Internal Code error 28906227 FRU List: NTUSER AJDGP01 IOP 28906228 FRU List: AJDGP01 IOP 28906501 FRU List: IOP AJDGP01 28906502 FRU List: AJDGP01 IOP 28906530 FRU List: NTVSCSI NTOPSYS 28906531 FRU List: NTVSCSI AS4NTDD NTOPSYS AJDGP01 28906532 FRU List: NTOPSYS AJDGP01 AS4NTDD A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Windows fatal error occurred A Windows fatal error occurred Windows initiated a warm boot A HostLAN error was detected
257
28906533 28906542
28906533 FRU List: NTUSER NTOPSYS AS4NTDD 28906534 FRU List: AS4NTDD AJDGP01 NTOPSYS 28906535 FRU List: NTUSER NTDEVDR AJDGP01 28906538 FRU List: NTVSCSI NTOPSYS 28906539 FRU List: NTVSCSI AS4NTDD NTOPSYS AJDGP01 2890653A FRU List: NTOPSYS AJDGP01 AS4NTDD AJDGP01 2890653B FRU List: NTUSER A Virtual SCSI error was detected A Virtual SCSI error was detected 28906541 FRU List: IOP AJDGP01 28906542 FRU List: AJDG301 Licensed Internal Code error detected. A permanent I/O processor failure occurred A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected NTOPSYS AS4NTDD 2890653C FRU List: AS4NTDD AJDGP01 NTOPSYS 2890653D FRU List: NTUSER NTDEVDR AJDGP01 2890653F FRU List: NTDEVDR NTOPSYS AJDG301 28906540 FRU List: NTVSCSI AJDGP01 AJDG301 A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected
258
28906543 2890B3E1
28906543 FRU List: NTOPSYS NTVSCSI 2890B3B4 28906580 FRU List: DISKIMG IOP AJDGP01 289065B0 FRU List: NTLANDD NTOPSYS 289065B1 FRU List: NTLANDD NTOPSYS AJDG301 289065B2 FRU List: NTDEVDR NTOPSYS AJDG301 28908301 FRU List: AJDGP01 IOP 2890B3B1 FRU List: IOP 2890B3B2 FRU List: IOP A permanent I/O processor failure occurred A permanent I/O processor failure occurred An I/O adapter failure occurred. 2890B3E0 FRU List: IOP MA_BRDG 2890B3E1 FRU List: IOP MA_BRDG An I/O adapter failure occurred. I/O processor detected a fault condition A HostLAN error was detected A HostLAN error was detected A HostLAN error was detected A Windows fatal error occurred FRU List: IOP 2890B3B5 FRU List: IOP 2890B3B6 FRU List: IOP 2890B3B7 FRU List: IOP 2890B3B8 FRU List: MA_BRDG IOP 2890B3B9 FRU List: IOP A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A Windows fatal error occurred 2890B3B3 FRU List: IOP A permanent I/O processor failure occurred
259
2890B4B0 2890BE00
2890B4B0 FRU List: IOP 2890B4B1 FRU List: IOP MEMORY 2890B4B2 FRU List: IOP 2890B4B3 FRU List: IOA 2890B4B4 FRU List: IOP IOA MEMORY 2890B4B5 FRU List: AJDGP01 IOP 2890B4B8 FRU List: MEMORY IOP AJDGP01 2890B4B9 FRU List: IOP 2890B4BC FRU List: IOP IOA I/O adapter error; logged only. An I/O adapter failure occurred. 2890BE00 FRU List: AJDGP01 IOP IOA MA_BRDG An I/O adapter failure occurred. Adapter card storage error An I/O adapter failure occurred. I/O adapter hardware error detected Incompatible hardware detected. Incompatible hardware detected. I/O adapter hardware error detected I/O adapter hardware error detected 2890B4BE FRU List: MEMORY IOP 2890B904 FRU List: AJDGP01 IOP 2890B935 FRU List: IOA AJDGP01 IOP MA_BRDG 2890B960 FRU List: AJDGP01 IOP IOA 2890B961 FRU List: IOA IOP An error was detected on one of the attached adapter cards. I/O processor Licensed Internal Code error Incompatible hardware detected. A permanent I/O processor failure occurred Adapter card storage error
260
28920A17 28926070
Servicer Response: The INS processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. FRU List: IOP AJDGP01 28921317
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates to replace hardware, then replace hardware. If the Failing Item indicates SVCDOCS, then do NOT replace hardware. This is a recoverable error. If the resource is not operable, use Hardware Service Manager to re-IPL the resource. Perform the VRYCFG command to Vary On the NWSD. FRU List: SVCDOCS
261
28926071 28926225
IOP 28926071 FRU List: AJDGP01 28926072 FRU List: AJDGP01 IOP 28926075 FRU List: AJDGP01 28926083 FRU List: AJDGP01 IOP 28926085 FRU List: AJDGP01 IOP MA_BRDG 28926201 FRU List: IOP AJDGP01 28926202 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error A permanent I/O processor failure occurred FRU List: DISKIMG AJDGP01 IOP MEMORY 28926225 FRU List: AJDGP01 AJDG301 IOP A permanent I/O processor failure occurred I/O adapter Licensed Internal Code failed. FRU List: IOP AJDGP01 28926224 A permanent I/O processor failure occurred I/O adapter Licensed Internal Code failed. I/O adapter resource not available. 28926222 FRU List: AJDGP01 IOP 28926223 A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O adapter Licensed Internal Code failed. I/O adapter Licensed Internal Code failed. 28926204 FRU List: IOP 28926210 FRU List: AJDGP01 28926221 FRU List: AJDG301 I/O processor resource not available I/O processor Licensed Internal Code error I/O adapter failure due to a thermal condition
262
28926226 2892653A
28926226 FRU List: AJDG301 AS4NTDD 28926227 FRU List: NTUSER AJDGP01 IOP 28926228 FRU List: AJDGP01 IOP 28926501 FRU List: IOP AJDGP01 28926502 FRU List: AJDGP01 IOP 28926538 28926530 FRU List: NTVSCSI NTOPSYS 28926539 28926531 FRU List: NTVSCSI AS4NTDD NTOPSYS NTOPSYS AJDGP01 AJDGP01 2892653A FRU List: NTOPSYS A Virtual SCSI error was detected A Virtual SCSI error was detected FRU List: NTVSCSI AS4NTDD A Virtual SCSI error was detected A Virtual SCSI error was detected FRU List: NTVSCSI NTOPSYS A Virtual SCSI error was detected A Windows fatal error occurred A Windows fatal error occurred Windows initiated a warm boot A HostLAN error was detected I/O processor card detected device error 28926532 FRU List: NTOPSYS AJDGP01 AS4NTDD 28926533 FRU List: NTUSER NTOPSYS AS4NTDD 28926534 FRU List: AS4NTDD AJDGP01 NTOPSYS 28926535 FRU List: NTUSER NTDEVDR AJDGP01 A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected
263
2892653B 28928301
AJDGP01 AS4NTDD 2892653B FRU List: NTUSER NTOPSYS AS4NTDD NTVSCSI 2892653C FRU List: AS4NTDD AJDGP01 IOP NTOPSYS AJDGP01 2892653D FRU List: NTUSER NTDEVDR NTOPSYS AJDGP01 289265B1 2892653F FRU List: NTDEVDR NTOPSYS AJDG301 AJDG301 289265B2 28926540 FRU List: NTVSCSI AJDGP01 AJDG301 AJDG301 28928301 28926541 FRU List: IOP AJDGP01 A permanent I/O processor failure occurred FRU List: AJDGP01 IOP An I/O adapter failure occurred. A Virtual SCSI error was detected FRU List: NTDEVDR NTOPSYS A HostLAN error was detected A Virtual SCSI error was detected FRU List: NTLANDD NTOPSYS A HostLAN error was detected A Virtual SCSI error was detected 289265B0 FRU List: NTLANDD A HostLAN error was detected A Virtual SCSI error was detected 28926580 FRU List: DISKIMG A Windows fatal error occurred A Virtual SCSI error was detected 28926542 FRU List: AJDG301 AJDGP01 28926543 FRU List: NTOPSYS A Windows fatal error occurred Licensed Internal Code error detected.
264
2892B3B1 2892B4B8
2892B3B1 FRU List: IOP 2892B3B2 FRU List: IOP 2892B3B3 FRU List: IOP 2892B3B4 FRU List: IOP 2892B3B5 FRU List: IOP 2892B3B6 FRU List: IOP 2892B3B7 FRU List: IOP 2892B3B8 FRU List: MA_BRDG IOP 2892B3B9 FRU List: IOP A permanent I/O processor failure occurred Multi-adapter bridge error detected. MEMORY 2892B4B5 FRU List: AJDGP01 IOP 2892B4B8 FRU List: MEMORY IOP Adapter card storage error An I/O adapter failure occurred. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 2892B3E0 FRU List: IOP MA_BRDG 2892B3E1 FRU List: IOP MA_BRDG 2892B4B0 FRU List: IOP 2892B4B1 FRU List: IOP MEMORY 2892B4B2 FRU List: IOP 2892B4B3 FRU List: IOA 2892B4B4 FRU List: IOP IOA I/O adapter hardware error detected Incompatible hardware detected. Incompatible hardware detected. I/O adapter hardware error detected I/O adapter hardware error detected An I/O adapter failure occurred. I/O processor detected a fault condition
265
2892B4B9 2892BE00
2892B4B9 FRU List: IOP 2892B4BC FRU List: IOP IOA 2892B4BE FRU List: MEMORY IOP 2892B904 FRU List: AJDGP01 IOP 2892B935 FRU List: IOA AJDGP01 IOP MA_BRDG 2892B960 FRU List: AJDGP01 IOP IOA 2892B961 FRU List: IOA IOP AJDGP01 An error was detected on one of the attached adapter cards. I/O processor Licensed Internal Code error Incompatible hardware detected. A permanent I/O processor failure occurred Adapter card storage error I/O adapter error; logged only. An I/O adapter failure occurred. 2892BE00 FRU List: AJDGP01 IOP IOA MA_BRDG An I/O adapter failure occurred.
266
2B200x31 2B2x00EE
Servicer Response: Replace the systembackplane. FRU List: SYSBKP2 2B208888 Operating system termination request received
Servicer Response: Informational message. 2B2x00EE An exception error has been reported on a processor
Servicer Response: The type of interrupt that caused the exception is specified by the x as follows: x Description ------------------- 0 Unknown interrupt 1 System reset interrupt (SRI) 2 Machine check interrupt (MCI) 3 Data storage interrupt (DSI) 4 Instruction storage interrupt (ISI) 5 External interrupt (EXI) 6 Alignment interrupt (ALI) 7 Program interrupt (SRI) 8 Floating unavailable interrupt (FUI) Do the following: 1. Check for system firmware updates, and apply if available. 2. Replace the system backplane. FRU List: SYSBKP2
267
268
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to analyze the problem. 34901xxx Tape unit failure
Servicer Response: Clean the tape path using the cleaning procedures in the 3490 Magnetic Tape Subsystem Operators Guide, GA32-0124. Usethe 3490 Tape Unit service information to continue analyzing the problem. FRU List: MHK0001DHK0002 34902008 Tape path dirty or read data check error
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to analyze the problem. 34902000 Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to analyze the problem. 34902001 Tape path dirty or write data check error
Servicer Response: Clean thetape path using the cleaning procedures in the 3490 Magnetic Tape Subsystem Operators Guide, GA32-0124. Use the 3490 Tape Unit service information to continue analyzing the problem. FRU List: MHK0001DHK0002 34902009 Tape path dirty or read identification record error
Servicer Response: Clean thetape path using the cleaning procedures in the 3490 Magnetic Tape Subsystem Operators Guide, GA32-0124. Use the 3490Tape Unit service information to continue analyzing the problem. FRU List: MHK0001DHK0002
Servicer Response:
269
34902010 34909100
Clean the tape path using the cleaning procedures in the 3490 Magnetic Tape Subsystem Operators Guide, GA32-0124. Usethe 3490 Tape Unit service information to continue analyzing the problem. FRU List: MHK0001DHK0002 34902010 Tape unit failure 3490206x Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 349021xx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 349022xx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 34902014 Recoverable tape unit failure; logged only
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 349023xx Tape Library failure
Servicer Response: No actionrequired. This reference code is logged for information only. 34902015 Tape unit failure
Servicer Response: Use the 3494 Tape Library DataserverMaintenance Information to analyze the problem. 34909020 I/O processor detected a SCSI bus configuration error
Servicer Response: Clean the tape path using the cleaningprocedures in the 3490 Magnetic Tape Subsystem Operators Guide, GA32-0124. Use the 3490 Tape Unit service information to continue analyzing the problem. FRU List: DHK0002 FI00856 FI00845 34902017 Write Protect violation reported by tape unit; loggedonly
Servicer Response: Before exchanging any parts, verify that the following conditions are not present: v Tape and DASD devices attached to the same type 6501 I/O processor v A device type or model that is not given support FRU List: UHKCNFG FI00851 FI00130 34909100 Interface error detected by I/O processor or by tapeunit
Servicer Response: No action required. This reference code is logged for informationonly. 3490202x Tape unit failure
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00856 05H3834
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490205x Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem.
270
34909200 34909350
EXTSCSI 61G8324 34909200 I/O processor addressed the tape unit; no response FI00856 FI00130 34909300 FRU List: DHK0002 34909301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00856 05H3834 EXTSCSI 61G8324 34909201 Tape unit command timeout
Servicer Response: The tape unit detected a hardware failure that does not prevent the tape unit from completing the present operation. See the 3590 Tape Unit service information to determine the failing item. FRU List: DHK0002 34909302 I/O processor Licensed Internal Code error
Servicer Response: If the system is operational, take a dump of the I/O processor data. For more information, see the Service Functions located in your host systems service guide, or contact your next level of support for assistance. FRU List: FI00130 34909310 FRU List: FI00851 FI00130 34909320 Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: Before exchanging any parts,do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00856 05H3834 EXTSCSI 61G8324 34909210 FRU List: FI00851 Illegal or unsupported tape unit response
Servicer Response: Do thefollowing: 1. Take a dump of the tape device Licensed Internal Code (see the 3490 Tape Drive service information). 2. Power off the tape unit. Then power on the tape unit to resume operation. FRU List: FI00851 34909350 Tape unit detected a read or write error on tape medium
Servicer Response:
271
34909351 34909900
A permanent read or write error occurred, and the tape unit determined that the tape cartridge is defective. Exchange the tape cartridge. FRU List: MHKTMEDUHKCLN FI00851 34909802 34909351 I/O processor Licensed Internal Code error I/O processor successfully recovered from temporaryerror 34909801 I/O processor successfully recovered from temporaryerror
Servicer Response: No action required. This reference code is logged for informationonly.
Servicer Response: If the system is operational, take a dump of the I/O processor data. For more information, see Service Functions located in your host systems service guide, or contact your next level of support for assistance FRU List: FI00130 34909355 The data format is incorrect; the tape cannot be read
Servicer Response: No action required. This reference code is logged for informationonly. 34909803 I/O processor successfully recovered from temporaryerror
Servicer Response: No action required. This reference code is logged for informationonly. 34909810 Problem analysis has determined a part should be replaced.
Servicer Response: The tape device does not give support to the data format on the tape cartridge. Re-initialize the tape cartridge or use a different tape cartridge. FRU List: MHKTMEDUHKCLN FI00851 34909500 I/O processor Licensed Internal Code error.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 34909899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UHKFIXD 34909900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: If the system is operational, take a dump of the I/O processor data. For more information, see Service Functions located in your host systems service guide, or contact your next level of support for assistance FRU List: FI00130 349096xx Tape unit failure
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape unit again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC.
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 34909800 I/O processor successfully recovered from temporaryerror
Servicer Response: No action required. This reference code is logged for informationonly.
272
3490Axxx 34942301
3490Axxx Tape unit failure Verifythe following: 1. That power is switched on in the 3490 Tape Unit Rack: v Set the 3490 Rack Unit Emergency Power Off switch to the On position. v Ensure that the 3490 Rack Enable/Off switch is set to the Enable position. v Press the 3490 Rack Power On button. 2. Verify the following on 3490 Tape Unit: v The Channel Enable/Disable switches are set to the Enable position. v The Normal/Test switch is set to the Normal position. v The CU Online/Offline switch is set to the Online position. v The Drive Address Online/Offline switches are set to the Online position. v The Drive DC Power switches are set to the On position. If you are attempting to perform an IPL from the device that had the error, verify that the drive control unit address switch has an address of hexadecimal 7 and the drive unit address switch has an address of 0. Use the 3490 Tape Unit service information to continue analyzing the problem. FRU List: UHK0003DHK0002 3490FFF6 Volume statistics; logged only
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490Bxxx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490Cxxx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490Dxxx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490Exxx Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490F00x Tape unit failure
Servicer Response: Use online problem analysis andthe 3490 Tape Unit service information to continue analyzing the problem. 3490FFD5 Device error reported; tape I/O processor
Servicer Response: No action required.This reference code is logged for information only.
Servicer Response:
273
34942303 34942321
Library attachment facilityequipment check. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: 3494 34942303 Library device failure 34942309 Library device failure. Library equipment check.
Servicer Response: Library equipment check. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: 3494 34942310 Library device requires operator intervention.
Servicer Response: Device control unit and librarymanager Licensed Internal Code are incompatible. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: DHALIBC DHADEVC 34942306 Library device failure. Library vision failure.
Servicer Response: Putthe library into pause mode and perform the intervention indicated on the library manager console. 34942311 Library device requires operator intervention.
Servicer Response: Library vision failure. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: 3494 34942307 Library device failure. Library vision failure.
Servicer Response: Putthe library into pause mode and perform the intervention indicated on the library manager console. 34942319 Tape unit failure.
Servicer Response: Use the tape unit service informationto analyze the failure. FRU List: FI00851 34942321 Library enclosure environmental alert was detected.
Servicer Response: Library vision failure. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: 3494 34942308 Library device failure.
Servicer Response: Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY PROBLEM - NO ERROR MESSAGE. FRU List: 3494
Servicer Response: Library manager equipmentcheck. Use the 3494 Tape Library Dataserver Maintenance Information and follow the procedures for analyzing a LIBRARY MANAGER HARDWARE PROBLEM FRU List: 3494
274
35709020 35709102
Servicer Response: Before exchanging any parts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O processor that does not support tape and DASD devices at the same time. v A device type or model that is not given support. FRU List: UHZCNFGDHZDEV FI00130 35709100 Interface error detected by I/O processor or by tapeunit
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 35709102 Gateway device detected a SCSI interface error
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: DHZDEV FI00131
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: DHZDEV FCGATE
275
35709200 35709301
35709200 I/O processor addressed the tape unit; no response 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: DHZDEV FI00131 05H3834 EXTSCSI 61G8324 35709210 FRU List: DHZDEV FI00131 FI00130 35709201 Tape unit command timeout 35709211 Gateway device detected a bus protocol error Servicer Response: Before exchanging any parts,do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: DHZDEV FI00131 05H3834 EXTSCSI 61G8324 35709300 35709202 Tape unit failed after Licensed Internal Code was loaded FRU List: DHZDEV 35709301 Tape device failure, redundancy lost Tape unit failure Illegal or unsupported tape unit response
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: DHZDEV FI00131 05H3834 EXTSCSI 61G8324
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA DHZDEV ANYFC FCCABLE EXTSCSI 61G8324
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable.
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation.
276
35709302 35709801
Refer to the 3570 Tape Unit service information to determine the failing item. FRU List: DHZDEV 35709302 I/O processor Licensed Internal Code error. 35709350 Tape unit detected a read or write error on tape medium
Servicer Response: A permanent read or write error occurred, and the tape unit determined that the tape cartridge is defective. Exchange the tape cartridge. FRU List: MHZTMEDUHZCLN DHZDEV 35709351 Tape with excessive error rate was mounted in tape device.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: FI00130 35709303 Gateway device failure
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MHZTMEDUHZCLN DHZDEV 35709355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 35709310 FRU List: DHZDEV FI00130 35709320 Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct.
Servicer Response: The tape unit does not give support to the data format on the tape cartridge. Use a different tape cartridge. FRU List: UHZUSERMHZTMED UHZCLN DHZDEV 35709500 I/O processor Licensed Internal Code error.
Servicer Response: Performthe following: 1. Take a dump of the tape unit Licensed Internal Code (see the 3570 Tape Unit service information). 2. Power off the tape unit. Then power on the tape unit to resume operation. 3. Ask your next level of support for assistance. FRU List: FI00130 DHZDEV
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: FI00130 35709800 I/O processor successfully recovered from temporaryerror
Servicer Response: No action required. This reference code is logged for informationonly. 35709801 I/O processor successfully recovered from temporaryerror
35709321
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE
Servicer Response: No action required. This reference code is logged for informationonly.
277
35709802 358x9020
35709802 I/O processor successfully recovered from temporaryerror FRU List: UHZFIXD 35709900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for informationonly. 35709803 I/O processor successfully recovered from temporaryerror
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UHZUSER 3570FFF6 Tape volume statistics logged (no action required).
Servicer Response: No action required. This reference code is logged for informationonly. 35709810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 35709899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected.
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached.
278
358x9100 358x9201
FRU List: UH7CNFG FI00871 PTFSRCH 358x9100 Interface error detected by system or by tape unit 358x9102 Gateway device detected a SCSI interface error
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 358x9200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 358x9101 Fibre Channel interface error detected
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 358x9201 Tape unit command timeout
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
Chapter 4. 3xxx Reference Codes
279
358x9202 358x9320
FI00872 DEVTERM MH7TMED 358x9202 Tape unit failed after Licensed Internal Code was loaded DEVTERM 358x9300 FRU List: FI00871 358x9301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 358x9210 FRU List: FI00871 FI01112 PTFSRCH 358x9211 Gateway device detected a bus protocol error Illegal or unsupported tape unit response
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 358x9302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871 358x9303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 358x9310 FRU List: PTFSRCH FI00871 358x9320 FRU List: FI00130 FI00871 Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct.
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE FI00872
280
358x9321 358x9899
358x9321 Gateway device Licensed Internal Code error 358x9500 Licensed Internal Code error.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 358x9350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. FRU List: PTFSRCH 358x9800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN
Servicer Response: No action required. This reference code is logged for information only. 358x9801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 358x9802 System successfully recovered from temporary I/O error
FI00871 358x9351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 358x9803 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED UH7CLN FI00871 358x9355 The data format is incorrect; the tape cannot be read
Servicer Response: No action required. This reference code is logged for information only. 358x9804 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 358x9810 Problem analysis has determined a part should be replaced.
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 358x9899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD
Chapter 4. 3xxx Reference Codes
281
358x9900 35929102
358x9900 Licensed Internal Code for tape unit was not upgraded FI00871 PTFSRCH 35929100 Interface error detected by system or by tape unit
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 358x9901 Tape performance statistics logged.
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 35929101 Fibre Channel interface error detected
Servicer Response: No action required. This reference code is logged for information only. 358x9902 An IOP dump was initiated
Servicer Response: No action required. 358xFFF6 Tape volume statistics logged (no action required) Tape unit configuration error
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA
35923202
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 35929020 Tape unit configuration error
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List:
282
35929200 35929211
FI00871 FCGATE FI00872 DEVTERM 35929200 Tape unit is not responding 35929202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 35929210 FRU List: FI00871 FI01112 Tape unit command timeout PTFSRCH 35929211 Gateway device detected a bus protocol error Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 35929201
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE FI00872 DEVTERM
283
35929300 35929355
35929300 FRU List: FI00871 35929301 Tape device failure, redundancy lost Tape unit failure FRU List: FCCODE 35929350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 35929302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 35929351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871 35929303 Gateway device failure
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED UH7CLN FI00871 35929355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 35929310 FRU List: PTFSRCH FI00871 35929320 FRU List: FI00130 FI00871 35929321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871
Servicer Response: Use thegateway device service documenation to analyze the problem.
284
35929500 3592FFF6
35929500 Licensed Internal Code error. This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 35929899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 35929800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 35929900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 35929801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 35929802 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 35929901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 35929803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 35929804 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 35929902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only. 35929810 Problem analysis has determined a part should be replaced.
Servicer Response: No action required. 3592FFF6 Tape volume statistics logged (no action required)
Servicer Response:
285
35909020 35909200
2. Check the device for any error indications. Refer to the device service information to resolve any error indications. 3. Clean the recording head in the tape device. 4. Attempt the failing operation again. Does the operation complete successfully? v Yes: You have corrected the problem. This ends the procedure. v No: Look at the 4 rightmost characters of the Data display for Function 11, which represent the unit reference code. Find the unit reference code in the following table.
35909020 I/O processor detected a SCSI bus configuration error 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE FI00851 FI00130 35909100 Interface error detected by I/O processor or by tapeunit 35909102 Gateway device detected a SCSI interface error
Servicer Response: Before exchanging any parts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O processor that does not support tape and DASD devices at the same time. v A device type or model that is not given support FRU List: UHQCNFG
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00851 FCGATE EXTSCSI 61G8324 35909200 I/O processor addressed the tape unit; no response
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00131 05H3834 EXTSCSI 61G8324 35909101 Fibre Channel interface error detected
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00131 05H3834
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors.
286
35909201 35909303
EXTSCSI 61G8324 35909201 Tape unit command timeout FI00131 FI00130 35909211 Gateway device detected a bus protocol error
Servicer Response: Before exchanging any parts,do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00131 05H3834 EXTSCSI 61G8324 35909202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00851 ANYFC FCCABLE EXTSCSI 61G8324 35909300 FRU List: FI00851 35909301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that an interposer is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable between the interposer and the device is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00851 FI00131 05H3834 EXTSCSI 61G8324
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the present operation. See the 3590 Tape Unit service information to determine the failing item. FRU List: FI00851 35909302 I/O processor Licensed Internal Code error.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. FRU List: FI00130 35909303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Chapter 4. 3xxx Reference Codes
287
35909310 35909810
35909310 FRU List: FI00851 FI00130 35909320 Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct 35909355 The data format is incorrect; the tape cannot be read
Servicer Response: The tape device does not give support to the data format on the tape cartridge. Format the tape cartridge again or use a different tape cartridge. See the 3590 Tape Drive Operators Guide for instructions on formatting a tape cartridge. FRU List: MHQTMEDUHQCLN FI00851 35909500 I/O processor Licensed Internal Code error.
Servicer Response: Do thefollowing: 1. Take a dump of the tape device Licensed Internal Code (see the 3590 Tape Unit service information). 2. Power off the tape unit. Then power on the tape unit to resume operation. FRU List: FI00130 FI00851 35909321 Gateway device Licensed Internal Code error
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: FI00130 35909800 I/O processor successfully recovered from temporaryerror
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 35909350 Tape unit detected a read or write error on tape medium
Servicer Response: No action required. This reference code is logged for informationonly. 35909801 I/O processor successfully recovered from temporaryerror
Servicer Response: A permanent read or write error occurred, and the tape unit determined that the tape cartridge is defective. Exchange the tape cartridge. FRU List: MHQTMEDUHQCLN FI00851 35909351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for informationonly. 35909802 I/O processor successfully recovered from temporaryerror
Servicer Response: No action required. This reference code is logged for informationonly. 35909803 I/O processor successfully recovered from temporaryerror
Servicer Response: The tape unit detected that the installed tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MHQTMEDUHQCLN FI00851
Servicer Response: No action required. This reference code is logged for informationonly. 35909810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only)
288
35909899 3590FFF6
35909899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UHQFIXD 35909900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape unit again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. 3590FFF6 Tape volume statistics logged (no action required)
289
290
Servicer Response: Replace the power supply. 40100111 FRU List: VRMOD VRM 1 failure
Servicer Response: The system will power itself down to standby when a critical temperature is reached. If this occurs, do the following: 1. Check the connections on the fan, and correct any problems that you find. 2. Verify that the airflow to the fan is not blocked, and correct any problems that you find.
Servicer Response: Look at the rollup LED card to identify the fan that failed, then do the following: 1. Check the connections on the fan, and correct any problems that you find. 2. Verify that the airflow to the fan is not blocked, and correct any problems that you find. 3. If you find no obvious problems, replace the fan. 40500111 Loss of rollup LED card
Servicer Response: Reseat the rollup LED card. You can reseat the rollup LED card while the system is powered on, but the system might reset and reboot.
291
432x102E 432x3130
Servicer Response: Perform DSKIP03. FRU List: DISKDRV STORIOA FI01106 FI01140
Servicer Response: Perform DSKIP03. FRU List: STORIOA DISKDRV FI01106 FI01140 432x3130 Device Licensed Internal Code
Servicer Response: If an MES is being installed, verify the configuration. FRU List: DISKDRV FI01106 STORIOA FI01140 432x3029 A device replacement has occurred
292
432x3131 432xFFF8
The device is not supported with the level of code currently on the system. Contact your next level of support. FRU List: SVCDOCS 432x3131 Device or IOA Licensed Internal Code 432x7052 Data compression warning
Servicer Response: Perform the procedure specified in Recovering From 6xxx7052 SRC in the Backup and Recovery Guide. FRU List: SVCDOCS 432xFFF2 FRU List: DISKDRV 432xFFF3 Disk media format not valid Disk motor problem
Servicer Response: The device does not support a needed attribute and is running with degraded performance. Contact your next level of support. FRU List: SVCDOCS 432x7000 Disk sector read error
FRU List: DISKDRV 432xFFF4 FRU List: DISKDRV STORIOA Disk device problem
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 432x7001 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 432x7003 Device format error
432xFFF5
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 432xFFF6 Disk device detected recoverable error
Servicer Response: If the disk has not been formatted by the system, initialize and format the disk. 432x7004 System log entry only. No service action required. Data compression failure
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 432xFFF7 Temporary disk data error
432x7050
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 432x7051 Compressed device and compression IOA are not compatible
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 432xFFF8 Temporary disk data error
Servicer Response: The customer should perform the procedure specified in Recovering From 6xxx7051 SRC in the Backup and Recovery Guide . FRU List: CMPRES1
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List:
Chapter 5. 4xxx Reference Codes
293
432xFFF9 433x3029
DISKDRV 432xFFF9 Temporary disk data error BACKPLN 432xFFFB SCSI bus reset occurred
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 432xFFFA Temporary disk bus error
Servicer Response: No action required. This reference code is logged for information only. 432xFFFE Temporary disk bus error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01140 FI01141
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01106 FI01140
STORIOA SASCABL SASEXP 433x3020 FRU List: Replacement device is not supported
STORIOA DISKDRV DEVBPLN STORIOA SASCABL SASEXP 433x3010 Disk device returned wrong response to IOA SASCABL 433x3029 Servicer: A device replacement has occurred
294
433x3100 433x70DD
No action required. This reference code is logged for information only. 433x3100 FRU List: DISKDRV Device bus interface error occurred 433x4060 Multipath redundancy level reduced Servicer: A redundant disk unit connection has failed. FRU List: STORIOA SASCABL SASEXP 433x3109 FRU List: DISKDRV IOA timed out a disk command SIP3153 SASCABL SASEXP 433x4061 Multipath redundancy level increased FRU List: SIP3146
Servicer: A redundant disk unit connection has been restored. No service action is required. 433x4100 Device bus fabric error
STORIOA SASCABL SASEXP 433x3110 FRU List: DISKDRV Device bus interface error occurred
STORIOA
Servicer: The device is not supported with the level of code currently on the system. Contact your next level of support. FRU List: SVCDOCS 433x34FF Format in progress
Servicer: No action required. This reference code is logged for information only. 433x7001 Temporary disk data error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV 433x70DD System log entry only.
Servicer: No action required. This reference code is logged for information only. 433x4041 Incomplete multipath connection
295
433xFFF3 4758B990
433xFFF3 FRU List: DISKDRV 433xFFF4 FRU List: DISKDRV Disk device problem Disk device problem 433xFFF9 Temporary disk data error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV 433xFFFA Temporary disk data error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV 433xFFF6 Disk device detected recoverable error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV 433xFFF7 Temporary disk data error
Servicer: No action required. This reference code is logged for information only. 433xFFFE Temporary disk bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: DISKDRV
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: SIP3150
296
4758B991 46859101
4758B991 FRU List: IOA FI00130 IOP 4758B992 Operating voltage and/or temperature Tampering of cryptographic card suspected. range limits exceeded. Servicer Response: Correct any conditions in the physical environment which may have caused the voltage and/or temperature out-of-range error on the 4758 adapter card. After the conditions have been corrected, vary off and then vary back on the 4758 device description associated with the 4758 adapter card. FRU List: CARDTMP
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 46859020 Tape unit configuration error
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 46859101 Fibre Channel interface error detected
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871
297
46859102 46859210
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 46859102 Gateway device detected a SCSI interface error DEVTERM 46859201 Tape unit command timeout
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 46859202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 46859200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 46859210 Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
298
46859211 46859351
FI01112 PTFSRCH 46859211 Gateway device detected a bus protocol error 46859303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 46859310 FRU List: PTFSRCH FI00871 Licensed Internal Code for the tape unit is not correct
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE FI00872 DEVTERM
Servicer Response: Use thegateway device service documenation to analyze the problem. Tape device failure, redundancy lost FRU List: FCCODE 46859350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 46859302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 46859351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Chapter 5. 4xxx Reference Codes
299
46859355 46859901
UH7CLN FI00871 46859355 The data format is incorrect; the tape cannot be read 46859803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 46859804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 46859500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 46859810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 46859899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 46859800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 46859900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 46859801 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 46859901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 46859802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only.
300
46859902 48126225
46859902 An IOP dump was initiated 4685FFF6 Tape volume statistics logged (no action required)
Servicer Response: Correct any conditions in the physical environment which may have caused the voltage and/or temperature out-of-range error on the 4764 adapter card. After the conditions have been corrected, vary off and then vary back on the 4764 device description associated with the 4764 adapter card. FRU List: CARDTMP
LICCODE DISKIMG 48126222 FRU List: FI00730 IOA 48126223 FRU List: IOA FI00730 48126225 A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
IOA
301
48126226 4812653A
48126226 FRU List: LICCODE AS4NTDD FI00730 48126227 FRU List: NTUSER FI00730 IOA 48126228 FRU List: FI00730 IOA 48126501 FRU List: IOA FI00730 48126502 FRU List: FI00730 IOA 48126530 FRU List: NTVSCSI NTOPSYS 48126531 FRU List: NTVSCSI AS4NTDD FI00730 NTOPSYS FI00730 4812653A FRU List: NTOPSYS A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Windows fatal error occurred A Windows fatal error occurred Windows initiated a warm boot Windows initiated a warm boot A Virtual SCSI error was detected 48126532 FRU List: NTOPSYS FI00730 AS4NTDD 48126533 FRU List: NTUSER NTOPSYS AS4NTDD 48126534 FRU List: AS4NTDD FI00730 NTOPSYS 48126535 FRU List: NTUSER NTDEVDR FI00730 48126538 FRU List: NTVSCSI NTOPSYS 48126539 FRU List: NTVSCSI AS4NTDD NTOPSYS A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected A Virtual SCSI error was detected
302
4812653B 4812B4B8
FI00730 AS4NTDD 4812653B FRU List: NTUSER NTOPSYS AS4NTDD NTVSCSI 4812653C FRU List: AS4NTDD FI00730 NTVSCSI NTOPSYS DISKIMG 4812653D FRU List: NTUSER NTDEVDR FI00730 4812653F FRU List: NTDEVDR NTOPSYS MEMORY LICCODE 4812B4B4 48126540 FRU List: NTVSCSI FI00730 LICCODE 48126541 FRU List: IOA FI00730 A permanent I/O processor failure occurred 4812B4B5 FRU List: FI00730 IOA 4812B4B8 FRU List: MEMORY IOA
Chapter 5. 4xxx Reference Codes
48126542 FRU List: LICCODE A Virtual SCSI error was detected FI00730 48126543 FRU List: NTOPSYS
A Virtual SCSI error was detected 48126580 FRU List: NTOPSYS A Windows fatal error occurred
IOA FI00730 4812B4B0 FRU List: IOA I/O adapter hardware error detected
A Virtual SCSI error was detected 4812B4B1 FRU List: IOA I/O adapter hardware error detected
303
4812B4B9 4B200122
4812B4B9 FRU List: IOA 4812B4BC FRU List: IOA 4812B4BE FRU List: MEMORY IOA Adapter card storage error I/O adapter error; logged only. An I/O adapter failure occurred. 4812B904 FRU List: FI00730 IOA 4812B960 FRU List: FI00730 IOP I/O processor Licensed Internal Code error A permanent I/O processor failure occurred
Servicer Response: If this error code only occurs once, it is not a problem. If this error code persists, replace the system backplane. FRU List: SYSBKP2 4B200120 Processor 0 failed to initialize
Servicer Response: On a two-way system, this error implies that one processor is still functioning, and the system will continue to operate in a degraded mode. At some point, you should replace the system backplane. FRU List: SYSBKP2 4B200121 Processor 1 failed to initialize
Servicer Response: On a two-way system, this error implies that one processor is still functioning, and the system will continue to operate in a degraded mode. At some point, you should replace the system backplane. FRU List: SYSBKP2 4B200122 FRU List: SYSBKP2 No processors were detected
304
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
DEVBPLN
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
DEVBPLN
SASCABL
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List:
DEVBPLN
SASEXP
SASEXP
Copyright IBM Corp. 2007, 2008
SASCABL
305
509A7614 509AFFF4
509A8404 STORIOA 509AFFF4 DEVBPLN 509A7614 A fatal error occurred on fan 1 System log entry only, no service action required Device backplane problem
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 509A7624 A fatal error occurred on fan 2
SASCABL
STORIOA
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 509A7634 A fatal error occurred on fan 3
DEVBPLN
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 509A7644 A fatal error occurred on fan 4
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 509A8401 Removable media power fault
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DEVBPLN
306
509D1511 5700A001
509D1511 A non-fatal error occurred on power supply 1 backplane command. Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
SASCABL SASEXP STORIOA 509D1515 A fatal error occurred on power supply 1 509D7614 A fatal error occurred on fan 1.
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKPWR
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: DISKFAN 509D8404 System log entry only, no service action required. Device backplane problem
509DFFF4
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
Servicer Response: Refer to the FRU list below and perform all actions before exchanging the suspect FRU. FRU List: SASEXP
SASCABL
SASCABL
STORIOA
307
5700B9A0 57021307
5700B9A0 FRU List: FI00719 FI00718 AJDGP01 FI00718 MA_BRDG AJDGP01 5700B9B0 FRU List: FI00719 LICCODE MA_BRDG LICCODE 5701A001 I/O adapter Licensed Internal Code error detected MA_BRDG I/O adapter hardware error detected MA_BRDG 5701B9B0 FRU List: FI00719 I/O adapter hardware error detected I/O adapter hardware error detected FRU List: AJDGP01 5701B9A0 FRU List: FI00719 I/O adapter hardware error detected
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 BACKPLN
308
57021310 57023021
57021310 I/O processor resource not available 57023001 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57021317 I/O processor card error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 57023002 Addressed device failed to respond to selection
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57022200 FRU List: AJDGP01 57022201 FRU List: USER FI01105 57022202 FRU List: FI00022 FI01105 57023000 FRU List: FI01101 IOP MA_BRDG A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor Licensed Internal Code error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 FI01141 FI01106 57023006 FRU List: IOP ANYBUS FI01101 57023020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57023021 I/O processor detected a SCSI bus configuration error
Servicer Response:
309
57023022 57023102
Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 57023087 STORIOA 57023022 I/O processor detected a SCSI bus configuration error I/O processor resource not available Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104 57023100 I/O processor card detected interface error AJDGP01 IOP FI01104 MA_BRDG
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57023023 I/O processor detected a SCSI bus configuration error
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57023101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57023080 FRU List: AJDGP01 57023081 System log entry only, no service action required. I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57023102 I/O processor card detected interface error
57023084
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List:
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107
310
57023103 57023141
STORIOA FI01140 BACKPLN 57023103 I/O processor card detected interface error A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57023121 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57023109 I/O processor timed out a device command
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57023122 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57023123 I/O Processor detected that the bus is not operational
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57023110 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57023136 FRU List: USER FI01105 57023140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57023120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 57023141 I/O Processor detected that the bus is now operational
Servicer Response:
Servicer Response:
311
57023142 57023401
This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 57023142 I/O Processor detected that the bus is now operational 57023205 Disk sector read error
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 57023215 Disk sector read error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 57023143 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 57023250 Disk unit requires initialization before use.
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 57023150 I/O processor detected a SCSI bus configuration error
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 57023300 Storage unit detected a media problem
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57023151 I/O processor detected a SCSI bus configuration error
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 57023400 I/O processor card detected device error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 57023200 FRU List: FI01105 STORIOA IOP MEDIA 57023203 FRU List: FI01105 Disk media format bad A tape/CD or disk device reported a failure
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 57023401 FRU List: DEVBPLN Device backplane problem
312
57023501 57028000
57023501 FRU List: AJDGP01 IOP 57023600 System log entry only, no service action required. System log entry only, no service action required. A permanent I/O processor failure occurred I/O processor Licensed Internal Code error 57026081 FRU List: AJDGP01 IOP 57026082 FRU List: AJDGP01 IOP 57026070 FRU List: IOP 57026071 FRU List: AJDGP01 57026072 FRU List: AJDGP01 IOP 57026073 FRU List: MEDIA FI01105 USER 57026075 FRU List: AJDGP01 57026076 FRU List: MEDIA AJDGP01 FI01105 I/O processor card detected media error I/O processor resource not available IPL device not ready FRU List: FCIOA OPT_CLN 57026201 FRU List: AJDGP01 57026602 FRU List: AJDGP01 57028000 A permanent IOP or cache adaptor card failure occurred. An I/O processor Licensed Internal Code error occurred. IOA LID is not valid I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error 57026083 FRU List: AJDGP01 IOP 57026085 FRU List: AJDGP01 IOP MA_BRDG 57026200 A permanent IOA hardware error occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error
57023601
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
Chapter 6. 5xxx Reference Codes
313
57028002 57028133
FRU List: STORIOA CACHE 57028002 A permanent cache adaptor card failure occurred. FRU List: CACHE STORIOA 57028011 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 57028004 FRU List: FI01141 STORIOA 57028005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 57028100 FRU List: AJDGP01 IOP 57028130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 57028007 A recoverable cache adaptor card error occurred.
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 57028131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57028132 IOA detected recoverable device bus error
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 57028010 A permanent cache adaptor card failure occurred.
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57028133 IOA detected recoverable device bus error
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown.
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only.
314
57028140 57028301
57028140 IOA detected recoverable device bus error 57028157 I/O adapter card error
Servicer Response: No actionis required. This reference code is logged for information only. 57028141 IOA detected recoverable device error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57028200 I/O processor Licensed Internal Code error
Servicer Response: No actionis required. This reference code is logged for information only. 57028145 FRU List: STORIOA 57028146 FRU List: FI01105 57028150 FRU List: STORIOA ANYBRDG 57028151 FRU List: AJDGP01 STORIOA I/O processor Licensed Internal Code error A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
FRU List: AJDGP01 IOP 57028300 I/O processor card or Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP
57028155 FRU List: AJDGP01 STORIOA 57028156 FRU List: AJDGP01 STORIOA
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101 AJDGP01 IOP
315
57028400 57029023
57028400 FRU List: AJDGP01 57029000 FRU List: FI01105 STORIOA 57029001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error 57029011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 57029012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE 57029013 The IOP and attached cache adaptor card are not compatible.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57029002 I/O processor card detected device error
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 57029020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57029008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57029021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57029022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 57029009 FRU List: SVCDOCS 57029010 Cache data associated with attached devices cannot befound . Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57029023 Array not functional due to present hardware configuration.
316
57029024 57029051
57029024 Array not functional due to present hardware configuration. than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57029030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57029025 Disk unit is not supported at its physical location.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57029031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 57029026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57029027 Array not functional due to present hardware configuration.
Servicer Response: No actionrequired. Protection will be automatically restarted. 57029040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 57029041 Background array parity check detected and corrected errors.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57029028 Incorrect hardware configuration change has been detected.
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 57029050 Required cache data cannot be located for a disk unit.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 57029029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 57029051 IOP cache data exists for a missing or failed device.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5702902F Array addendum Product Activity Log entry
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more
317
57029052 5702B3B4
57029052 Cache data exists for device that has been modified. 57029090 Disk unit has been modified after the last known status.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 57029053 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57029091 Incorrect hardware configuration change has been detected.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57029054 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57029092 Disk unit requires initialization before use.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57029081 FRU List: FI01105 STORIOA 57029082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 5702B3B1 FRU List: IOP 5702B3B2 FRU List: IOP 5702B3B3 FRU List: IOP 5702B3B4 A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
318
5702B3B5 570B0A17
5702B3B5 FRU List: IOP 5702B3B6 FRU List: IOP 5702B3B7 FRU List: IOP 5702B3B8 FRU List: MA_BRDG IOP 5702B3B9 FRU List: IOP 5702B3E0 FRU List: IOP MA_BRDG 5702FF3D 5702B3E1 FRU List: IOP MA_BRDG 5702FF6D 5702B410 FRU List: STORIOA 5702B411 FRU List: STORIOA A permanent I/O processor failure occurred A permanent I/O processor failure occurred FRU List: IOP ANYBUS 570B0A17 FRU List: IOP MA_BRDG A permanent I/O processor failure occurred I/O processor detected a recoverable system bus error. I/O processor detected a fault condition. FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error I/O processor detected a fault condition. A permanent I/O processor failure occurred Multi-adapter bridge error detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred 5702B412 Tape/CD or disk bus interface error occurred
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 5702B935 FRU List: FI01101 AJDGP01 IOP MA_BRDG 5702BE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG I/O processor detected a fault condition. Unknown hardware detected
319
570B0A22 570B3002
AJDGP01 AJDG301 570B0A22 FRU List: AJDGP01 AJDG301 IOP MA_BRDG 570B102E FRU List: FI01105 570B1306 I/O processor card or Licensed Internal Code error Out of alternate sectors for disk storage 570B2201 FRU List: USER FI01105 570B2202 FRU List: FI00022 FI01105 IOP FI01104 BACKPLN 570B1307 FRU List: AJDGP01 AJDG301 570B1310 I/O processor resource not available I/O processor resource not available 570B3000 FRU List: FI01101 IOP MA_BRDG 570B3001 Not valid condition in I/O Processor Licensed InternalCode A permanent I/O processor failure occurred Removable media error during IPL Removable media error during IPL I/O processor detected a storage transfer error 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 570B2200 FRU List: AJDGP01 I/O processor Licensed Internal Code error
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01
Servicer Response: The I/O processorerror log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 570B1317 I/O processor card error
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: IOP AJDGP01 570B3002 Addressed device failed to respond to selection
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates IOP, then replace the IOP. If the Failing Item indicates SVCDOCS, then do NOT replace the IOP. This is a recoverable error. Perform the following:
320
570B3006 570B3087
FI01105 STORIOA FI01140 FI01141 FI01106 570B3006 FRU List: IOP ANYBUS FI01101 570B3020 I/O processor detected a SCSI bus configuration error System bus error USER FI01107 STORIOA 570B3023 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 570B3080 FRU List: AJDGP01 570B3081 System log entry only, no service action required. I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 570B3021 I/O processor detected a SCSI bus configuration error
570B3084
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: AJDGP01 IOP FI01104 MA_BRDG 570B3087 I/O processor resource not available
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 570B3022 I/O processor detected a SCSI bus configuration error
Servicer Response: The LicensedInternal Code could not allocate resources on the I/O processor card. FRU List: AJDGP01 AJDG301 IOACNFG FI01104
Chapter 6. 5xxx Reference Codes
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List:
321
570B3100 570B3122
570B3100 I/O processor card detected interface error 570B3109 I/O processor timed out a device command
Servicer Response: Erroroccurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 570B3101 I/O processor card detected interface error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 570B3110 I/O processor card detected interface error
Servicer Response: Erroroccurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 570B3102 I/O processor card detected interface error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 570B3120 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 570B3103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 570B3121 I/O Processor detected that the bus is not operational
Servicer Response: Erroroccurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 570B3122 I/O Processor detected that the bus is not operational
Servicer Response:
322
570B3123 570B3215
A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 570B3123 I/O Processor detected that the bus is not operational 570B3150 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 570B3151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 570B3136 FRU List: USER FI01105 570B3140 I/O Processor detected that the bus is now operational The removable media device is assigned elsewhere
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 570B3200 FRU List: FI01105 STORIOA IOP MEDIA 570B3203 FRU List: FI01105 570B3205 Disk sector read error Disk media format bad A tape/CD or disk device reported a failure
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 570B3141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 570B3142 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105 570B3215 Disk sector read error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 570B3143 I/O Processor detected that the bus is now operational
Servicer Response: Disk unit data may need tobe reloaded, but the disk unit does not need to be replaced. FRU List: FI01105
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational.
323
570B3250 570B6082
570B3250 Disk unit requires initialization before use. 570B6070 FRU List: IOP 570B6071 Storage unit detected a media problem FRU List: AJDGP01 570B6072 FRU List: AJDGP01 IOP I/O processor card detected device error 570B6073 FRU List: MEDIA FI01105 USER 570B6075 FI01106 DEVTERM FI01140 570B3401 FRU List: DEVBPLN 570B3501 FRU List: AJDGP01 IOP 570B3600 System log entry only, no service action required. System log entry only, no service action required. I/O processor Licensed Internal Code error Device backplane problem FRU List: AJDGP01 570B6076 FRU List: MEDIA AJDGP01 FI01105 570B6081 FRU List: AJDGP01 IOP 570B6082 FRU List: AJDGP01 IOP I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error I/O processor card detected media error I/O processor resource not available IPL device not ready I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error A permanent I/O processor failure occurred
Servicer Response: Performa D-IPL and work on errors found in the log. FRU List: USER 570B3300
Servicer Response: Perform IOPIP01. FRU List: MEDIA FI00121 FI01141 570B3400
Servicer Response: NOTE: Ifexternal devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA
570B3601
324
570B6083 570B8011
570B6083 FRU List: AJDGP01 IOP 570B6085 FRU List: AJDGP01 IOP MA_BRDG 570B6200 FRU List: FCIOA OPT_CLN 570B6201 FRU List: AJDGP01 570B6602 FRU List: AJDGP01 570B8000 A permanent IOP or cache adaptor card failure occurred. An I/O processor Licensed Internal Code error occurred. IOA LID is not valid Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 570B8010 A permanent cache adaptor card failure occurred. A permanent IOA hardware error occurred Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 570B8007 A recoverable cache adaptor card error occurred. I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error STORIOA 570B8004 FRU List: FI01141 STORIOA 570B8005 A recoverable IOP or cache adaptor card error occurred. Voltage drop detected on I/O processor 5 volt powersupply.
Servicer Response:
Servicer Response:
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: STORIOA CACHE 570B8002 A permanent cache adaptor card failure occurred.
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE STORIOA 570B8011 A permanent cache adaptor card failure occurred.
Servicer Response: Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List: CACHE
Servicer Response: The cache adaptor card may be missing, broken or incompatible. Note: DO NOT replace both FRUs at the same time. Exchange the FRUs one at a time in the order shown. FRU List:
Chapter 6. 5xxx Reference Codes
325
570B8100 570B8157
CACHE STORIOA 570B8100 FRU List: AJDGP01 IOP ANYBRDG 570B8130 IOA detected recoverable device bus error 570B8151 FRU List: AJDGP01 STORIOA 570B8155 FRU List: AJDGP01 STORIOA 570B8156 FRU List: AJDGP01 STORIOA 570B8157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error I/O processor Licensed Internal Code error 570B8146 FRU List: FI01105 570B8150 FRU List: STORIOA A permanent I/O processor failure occurred Disk device detected recoverable error
Servicer Response: An erroroccurred on SCSI bus 0. No action is required. This reference code is logged for information only. 570B8131 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 1. No action is required. This reference code is logged for information only. 570B8132 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 2. No action is required. This reference code is logged for information only. 570B8133 IOA detected recoverable device bus error
Servicer Response: An erroroccurred on SCSI bus 3. No action is required. This reference code is logged for information only. 570B8140 IOA detected recoverable device bus error
Servicer Response: No actionis required. This reference code is logged for information only. 570B8141 IOA detected recoverable device error
Servicer Response: Display the Service ActionLog entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS
Servicer Response: No actionis required. This reference code is logged for information only. 570B8145 FRU List: STORIOA A recoverable I/O processor error occurred.
326
570B8200 570B9012
570B8200 FRU List: AJDGP01 IOP 570B8300 I/O processor card or Licensed Internal Code error I/O processor Licensed Internal Code error 570B9002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 570B9008 I/O card does not support functions expected by devices
Servicer Response: A microprocessor exception occurred on the I/O processor. FRU List: STORIOA IOP AJDGP01 570B8301 Not valid condition in I/O Processor Licensed InternalCode
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 570B9009 FRU List: SVCDOCS 570B9010 Cache data associated with attached devices cannot befound . Perform IOPIP31. Call your next level of support for assistance
Servicer Response: The Licensed Internal Code found a condition that should not haveoccurred. FRU List: FI01101 AJDGP01 IOP 570B8400 FRU List: AJDGP01 570B9000 FRU List: FI01105 STORIOA 570B9001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error
FRU List: SVCDOCS 570B9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 570B9012 IOP requires a cache adaptor card but cannot find it.
Servicer Response: The cache adapter card is missing or broken. Perform IOPIP29. FRU List: CACHE
327
570B9013 570B9030
570B9013 The IOP and attached cache adaptor card are not compatible. 570B9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP19. FRU List: SVCDOCS 570B9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 570B9027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 570B9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 570B9028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 570B9022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 570B9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 570B9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 570B902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 570B9024 Array not functional due to present hardware configuration.
Servicer Response: This entrycontains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 570B9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 570B9025 Disk unit is not supported at its physical location.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS
328
570B9031 570B9091
570B9031 Array protection temporarily suspended SVCDOCS 570B9054 IOP resources not available due to previous problems.
Servicer Response: No actionrequired. Protection will be automatically restarted. 570B9040 Array protection temporarily suspended
Servicer Response: No actionrequired. Protection will be automatically restarted. 570B9041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 570B9081 FRU List: FI01105 STORIOA I/O processor card detected device error
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 570B9050 Required cache data cannot be located for a disk unit.
570B9082
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 570B9051 IOP cache data exists for a missing or failed device.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 570B9090 Disk unit has been modified after the last known status.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 570B9052 Cache data exists for device that has been modified.
Servicer Response: Perform IOPIP28. FRU List: SVCDOCS 570B9053 IOP resources not available due to previous problems.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 570B9091 Incorrect hardware configuration change has been detected.
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List:
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
Chapter 6. 5xxx Reference Codes
329
570B9092 570BB935
570B9092 Disk unit requires initialization before use. 570BB3B9 FRU List: IOP 570BB3E0 A permanent I/O processor failure occurred FRU List: IOP MA_BRDG 570BB3E1 570BB3B2 FRU List: IOP 570BB3B3 FRU List: IOP 570BB3B4 FRU List: IOP 570BB3B5 FRU List: IOP 570BB3B6 FRU List: IOP 570BB3B7 FRU List: IOP 570BB3B8 FRU List: MA_BRDG IOP Multi-adapter bridge error detected. AJDGP01 IOP MA_BRDG A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred FRU List: IOP MA_BRDG 570BB410 FRU List: STORIOA 570BB411 FRU List: STORIOA 570BB412 Tape/CD or disk bus interface error occurred A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor detected a fault condition. I/O processor detected a fault condition. A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 570BB3B1 FRU List: IOP
Servicer Response: Perform IOPIP16. FRU List: FI01107 FI01140 STORIOA DEVTERM 570BB935 FRU List: FI01101 Unknown hardware detected
330
570BBE00 57033023
570BBE00 FRU List: AJDGP01 IOP FI01104 MA_BRDG 570BFF3D I/O adapter detected a recoverable error FRU List: IOP ANYBUS I/O processor detected a fault condition. FRU List: STORIOA ANYBRDG 570BFF6D I/O processor detected a recoverable system bus error.
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57033006 FRU List: IOP ANYBUS STORIOA 57033020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57033021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57033023 I/O processor detected a SCSI bus configuration error
Servicer Response:
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER
331
57033100 57033141
FI01107 STORIOA 57033100 I/O processor card detected interface error BACKPLN 57033120 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033101 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033121 I/O Processor detected that the bus is not operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033122 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033102 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033123 I/O Processor detected that the bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57033103 I/O processor card detected interface error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57033140 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 57033141 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational.
332
57033142 57038130
57033142 I/O Processor detected that the bus is now operational 57033501 FRU List: AJDGP01 IOP 57033600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 57033143 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 57033150 I/O processor detected a SCSI bus configuration error
57033601
57038008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 57038009 FRU List: CACHBAT 57038012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57033151 I/O processor detected a SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 57033400 FRU List: FI02112 STORIOA FI01106 DEVTERM FI01140 57033401 FRU List: DEVBPLN Device backplane problem I/O processor card detected device error
FRU List: SVCDOCS 57038100 FRU List: AJDGP01 IOP 57038130 IOA detected recoverable device bus error I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.
333
57038131 57039000
57038131 IOA detected recoverable device bus error ANYBRDG 57038151 FRU List: AJDGP01 STORIOA 57038155 FRU List: AJDGP01 STORIOA 57038156 FRU List: AJDGP01 STORIOA 57038157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57038132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57038133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 57038140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 57038141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 57038145 FRU List: STORIOA 57038146 FRU List: FI01105 57038150 A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57038200 FRU List: AJDGP01 IOP 57039000 FRU List: FI01105 STORIOA I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA
334
57039001 57039025
57039001 I/O processor card detected device configuration error 57039015 Mode jumper missing
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57039002 I/O processor card detected device error
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 57039020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57039008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57039021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57039022 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 57039009 FRU List: SVCDOCS 57039010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 57039011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 57039014 Mode jumper overridden due to cache data in conflicting mode See JOVERRIDE.
335
57039026 57039053
57039026 Array not functional due to present hardware configuration. 57039031 Array protection temporarily suspended
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57039027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 57039040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 57039041 Background array parity check detected and corrected errors.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57039028 Incorrect hardware configuration change has been detected.
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 57039050 Required cache data cannot be located for a disk unit.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS 57039029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 57039051 IOP cache data exists for a missing or failed device.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5703902F Array addendum Product Activity Log entry
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 57039052 Cache data exists for device that has been modified.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57039030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57039053 IOP resources not available due to previous problems.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS
336
57039054 5703FF6D
57039054 IOP resources not available due to previous problems. 57039090 Disk unit has been modified after the last known status.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57039071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57039091 Incorrect hardware configuration change has been detected.
Servicer Response: No service action required. 57039072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57039092 Disk unit requires initialization before use.
Servicer Response: No service action required. 57039073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57039081 FRU List: FI01105 STORIOA 57039082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 57039093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5703B934 FRU List: STORIOA 5703FF3D FRU List: STORIOA ANYBRDG 5703FF6D FRU List: IOP ANYBUS
Chapter 6. 5xxx Reference Codes
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
337
57091310 57093102
57091310 I/O processor resource not available STORIOA 57093023 I/O processor detected a SCSI bus configuration error
Servicer Response: The I/O processor error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57093006 FRU List: IOP ANYBUS STORIOA 57093020 I/O processor detected a SCSI bus configuration error System bus error
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57093100 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57093021 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093101 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107 STORIOA 57093022 I/O processor detected a SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093102 I/O processor card detected interface error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. Use the failing item (FI) codes to find failing devices. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
338
57093103 57093400
57093103 I/O processor card detected interface error 57093140 I/O Processor detected that the bus is now operational
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 57093120 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since SCSI bus 0 is now operational. 57093141 I/O Processor detected that the bus is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since SCSI bus 1 is now operational. 57093142 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 0 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093121 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action, since SCSI bus 2 is now operational. 57093143 I/O Processor detected that the bus is now operational
Servicer Response: A device was added to SCSI bus 1 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093122 I/O Processor detected that the bus is not operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action, since SCSI bus 3 is now operational. 57093150 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 2 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57093123 I/O Processor detected that the bus is not operational
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57093151 I/O processor detected a SCSI bus configuration error
Servicer Response: A device was added to SCSI bus 3 of the I/O Adapter and caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 57093400 FRU List: FI02112 STORIOA I/O processor card detected device error
339
57093401 57098145
FI01106 DEVTERM FI01140 57093401 FRU List: DEVBPLN 57093501 FRU List: AJDGP01 IOP 57093600 System log entry only, no service action required System log entry only, no service action required A permanent cache battery pack failure occurred I/O processor Licensed Internal Code error Device backplane problem FRU List: AJDGP01 IOP 57098130 IOA detected recoverable device bus error 57098100 I/O processor Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 57098131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57098132 IOA detected recoverable device bus error
57093601
57098008
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57098133 IOA detected recoverable device bus error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 57098009 FRU List: CACHBAT 57098012 Attached read cache devices exceed capacity supported by IOA. Reduce the number of read caches on the IOA. Impending cache battery pack failure
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 57098140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 57098141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 57098145 FRU List: STORIOA A recoverable I/O processor error occurred.
340
57098146 57099008
57098146 FRU List: FI01105 57098150 A permanent I/O processor failure occurred Disk device detected recoverable error re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57098200 FRU List: AJDGP01 IOP 57099000 FRU List: FI01105 STORIOA I/O processor Licensed Internal Code error 57099001 I/O processor card detected device configuration error I/O processor card detected device error I/O processor Licensed Internal Code error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 57098151 FRU List: AJDGP01 STORIOA 57098155 FRU List: AJDGP01 STORIOA 57098156 FRU List: AJDGP01 STORIOA 57098157 I/O adapter card error A permanent I/O processor failure occurred A permanent I/O processor failure occurred
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57099002 I/O processor card detected device error
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57099008 I/O card does not support functions expected by devices
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to
341
57099009 57099028
57099009 FRU List: SVCDOCS 57099010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance SVCDOCS 57099023 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099024 Array not functional due to present hardware configuration.
FRU List: SVCDOCS 57099011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 57099014 Mode jumper overridden due to cache data in conflicting mode. See JOVERRIDE.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 57099026 Array not functional due to present hardware configuration.
Servicer Response: See Mode jumper is missing in Storage I/O card modes and jumpers. FRU List: SVCDOCS 57099020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57099027 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57099021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57099028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 57099022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on IOP. Either move all devices in an array to another IOP that supports arrays, or stop an array on this IOP. FRU List: SVCDOCS
342
57099029 57099072
57099029 Incorrect hardware configuration change has been detected. 57099051 IOP cache data exists for a missing or failed device.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5709902F Array addendum Product Activity Log entry
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code. Otherwise, perform IOPIP27. FRU List: SVCDOCS 57099052 Cache data exists for device that has been modified.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 array members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57099030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57099053 IOP resources not available due to previous problems.
Servicer Response:: Perform isolation procedure IOPIP21. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57099031 Array protection temporarily suspended
Servicer Response: Take action on other IOP reference codes which have surfaced. If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57099054 IOP resources not available due to previous problems.
Servicer Response: No action required. Protection will be automatically restarted. 57099040 Array protection temporarily suspended
Servicer Response: No action required. Protection will be automatically restarted. 57099041 Background array parity check detected and corrected errors. Call your next level of support to report the problem.
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other IOP reference codes and take action on them. FRU List: SVCDOCS 57099071 Link from IOA to auxiliary cache IOA went operational
Servicer Response:: Call your next level of support to report the problem. FRU List: AJDGP01 57099050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 57099072 Link from IOA to auxiliary cache IOA went non-operational
343
57099073 5709FF6D
57099073 Incompatible or non-operational auxiliary cache IOA attached. 57099092 Disk unit requires initialization before use.
Servicer Response:: Perform isolation procedure IOPIP40. Tip: All of the isolation procedures are located in your host servers service guide. FRU List: SVCDOCS 57099081 FRU List: FI01105 STORIOA 57099082 I/O processor card detected device error I/O processor card detected device error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 57099093 Read cache device not in correct format
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 5709B934 FRU List: STORIOA 5709FF3D FRU List: STORIOA ANYBRDG 5709FF6D FRU List: IOP I/O processor detected a recoverable system bus error I/O adapter detected recoverable error Incompatible hardware detected.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57099090 Disk unit has been modified after the last known status.
ANYBUS
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57099091 Incorrect hardware configuration change has been detected.
Servicer Response: Re-IPL the system. If any reference codes are surfaced, go to the list of system reference codes and use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
344
57043020 57048150
Servicer Response: Eithertoo many devices or the wrong kind of devices have been configured under the IOA. Change the configuration. FRU List: SVCDOCS 57043100 FRU List: FCINTF ANYFC FCIOA OPT_CLN 57043120 FRU List: FCPORT FCIOA FCDEV OPT_CLN 57043140 I/O Processor detected that a port is now operational I/O processor detected a port failure I/O processor card detected interface error
Servicer Response: The device indicated that a formatis in progress. When the format is complete, the device should be useable. No action is required. This reference code is logged for information only. 57048130 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 57048140 Recovered Fibre Channel interface error
Servicer Response: No actionrequired. This reference code is logged for information only. 57048141 IOA detected recoverable device error
Servicer Response: No actionrequired. This reference code is logged for information only. 57048145 FRU List: FCIOA OPT_CLN 57048146 FRU List: FCDEV 57048150 FRU List: FCIOA ANYBRDG OPT_CLN A permanent I/O processor failure occurred Disk device detected recoverable error A recoverable I/O processor error occurred.
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. 57043400 FRU List: FCDEV FCINTF ANYFC FCIOA I/O processor card detected device error
345
57048151 5704FF3D
57048151 FRU List: AJDGP01 FCIOA OPT_CLN IOP OPT_CLN 57048155 FRU List: AJDGP01 FCIOA OPT_CLN 57048156 FRU List: AJDGP01 FCIOA OPT_CLN 57049091 Incorrect hardware configuration change has been detected. A permanent I/O processor failure occurred A permanent I/O processor failure occurred I/O processor Licensed Internal Code error 5704FF3D FRU List: FCIOA ANYBRDG Recovered IOA error
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS 57049092 Incorrect hardware configuration change has been detected.
Servicer Response: Reset the I/O processor and then IPL the I/O processor. For information about how to reset and IPL the I/O processor, see Debug the resource. If an I/O processor reset and I/O processor IPL does not resolve the problem, contact your next level of support. FRU List: SVCDOCS
346
5706A001 57088008
Servicer Response: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.
Servicer Response: Error occurred on SCSI bus 0. FRU List: AUXCBL AUXIOA PRIMIOA 57083101 Interface error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT
Chapter 6. 5xxx Reference Codes
347
57088009 57088302
AUXIOA 57088009 FRU List: CACHBAT 57088130 IOA detected recoverable SCSI bus error Impending cache battery pack failure 57088155 FRU List: PTFSRCH AUXIOA 57088156 FRU List: PTFSRCH AUXIOA 57088131 IOA detected recoverable SCSI bus error 57088157 I/O adapter card error Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 57088300 FRU List: AUXIOA A permanent failure occurred. ANYBRDG PTFSRCH 57088301 FRU List: PTFSRCH AUXIOA 57088302 Missing Licensed Internal Code Not valid condition in Licensed Internal Code IOA hardware or PCI bus error A permanent failure occurred A permanent failure occurred
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57088140 IOA detected recoverable SCSI bus error
Servicer Response: No action is required. This reference code is logged for information only. 57088141 IOA detected recoverable SCSI resource error
Servicer Response: No action is required. This reference code is logged for information only. 57088145 FRU List: AUXIOA 57088150 A recoverable error occurred
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: AUXIOA ANYBRDG 57088151 FRU List: PTFSRCH AUXIOA Licensed Internal Code error
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS AUXIOA
348
57089055 574F8130
57089055 Write cache data is available for attached storage IOA PRIMIOA 574F3101 Interface error
Servicer Response: No service action required. 57089071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Error occurred on SCSI bus 1. FRU List: AUXCBL AUXIOA PRIMIOA 574F3400 FRU List: AUXCBL PRIMIOA 574F6075 FRU List: PTFSRCH 574F8008 A permanent cache battery pack failure occurred I/O processor resource not available SCSI resource error
Servicer Response: No service action required. 57089072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: No service action required. 57089073 Disconnected, incompatible, or non-operational storage IOA. Perform isolation procedure IOPIP41. To review isolation procedure IOPIP41, go to your host servers service guide.
FRU List: SVCDOCS 5708FF3D FRU List: AUXIOA ANYBRDG 574F1310 I/O adapter resource not available I/O adapter detected a recoverable error
Servicer Response:: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT AUXIOA 574F8009 FRU List: CACHBAT 574F8130 IOA detected recoverable SCSI bus error Impending cache battery pack failure
Servicer Response: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 574F3006 FRU List: AUXIOA ANYBRDG IOP 574F3100 Interface error System bus error
Servicer Response: Error occurred on SCSI bus 0. FRU List: AUXCBL AUXIOA
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only.
349
574F8131 574F9055
574F8131 IOA detected recoverable SCSI bus error 574F8156 FRU List: PTFSRCH AUXIOA 574F8140 IOA detected recoverable SCSI bus error 574F8157 I/O adapter card error Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS A permanent failure occurred 574F8300 FRU List: AUXIOA ANYBRDG PTFSRCH 574F8301 FRU List: PTFSRCH AUXIOA 574F8151 FRU List: PTFSRCH AUXIOA 574F8155 FRU List: PTFSRCH AUXIOA A permanent failure occurred Licensed Internal Code error 574F8302 Missing Licensed Internal Code Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS AUXIOA 574F9055 Write cache data is available for attached storage IOA Not valid condition in Licensed Internal Code IOA hardware or PCI bus error A permanent failure occurred
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
Servicer Response: No action is required. This reference code is logged for information only. 574F8141 IOA detected recoverable SCSI resource error
Servicer Response: No action is required. This reference code is logged for information only. 574F8145 FRU List: AUXIOA 574F8150 A recoverable error occurred
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: AUXIOA ANYBRDG
350
574F9071 575B8131
574F9071 Link from IOA to auxiliary cache IOA went operational 575B3101 Interface error
Servicer Response: No service action required. 574F9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Error occurred on SCSI bus 1. FRU List: AUXCBL AUXIOA PRIMIOA 575B3400 FRU List: AUXCBL PRIMIOA 575B6075 I/O processor resource not available SCSI resource error
Servicer Response: No service action required. 574F9073 Disconnected, incompatible, or non-operational storage IOA. Perform isolation procedure IOPIP41. To review isolation procedure IOPIP41, go to your host servers service guide.
FRU List: SVCDOCS 574FFF3D FRU List: AUXIOA ANYBRDG 575B1310 I/O adapter resource not available I/O adapter detected a recoverable error
FRU List: PTFSRCH 575B8008 A permanent cache battery pack failure occurred
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT AUXIOA 575B8009 Interface error FRU List: CACHBAT 575B8130 IOA detected recoverable SCSI bus error Impending cache battery pack failure
Servicer Response: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 575B3006 FRU List: AUXIOA ANYBRDG IOP 575B3100 System bus error
Servicer Response: Error occurred on SCSI bus 0. FRU List: AUXCBL AUXIOA PRIMIOA
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 575B8131 IOA detected recoverable SCSI bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only.
351
575B8140 575B9071
575B8140 IOA detected recoverable SCSI bus error 575B8157 I/O adapter card error
Servicer Response: No action is required. This reference code is logged for information only. 575B8141 IOA detected recoverable SCSI resource error
Servicer Response: No action is required. This reference code is logged for information only. 575B8145 FRU List: AUXIOA 575B8150 A permanent failure occurred A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to:1. If the I/O Processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On.2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 575B8300 FRU List: AUXIOA ANYBRDG PTFSRCH 575B8301 FRU List: PTFSRCH AUXIOA Not valid condition in Licensed Internal Code IOA hardware or PCI bus error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: AUXIOA ANYBRDG 575B8151 FRU List: PTFSRCH AUXIOA 575B8155 FRU List: PTFSRCH AUXIOA 575B8156 FRU List: PTFSRCH AUXIOA A permanent failure occurred A permanent failure occurred Licensed Internal Code error
575B8302
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS AUXIOA 575B9055 Write cache data is available for attached storage IOA
Servicer Response: No service action required. 575B9071 Link from IOA to auxiliary cache IOA went operational
352
575B9072 576B3140
575B9072 Link from IOA to auxiliary cache IOA went non-operational FRU List: SVCDOCS 575BFF3D FRU List: AUXIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: No service action required. 575B9073 Disconnected, incompatible, or non-operational storage IOA. Perform isolation procedure IOPIP41. To review isolation procedure IOPIP41, go to your host servers service guide.
Servicer Response: Too many devices have been configured on port 0. Change the configuration. FRU List: SVCDOCS 576B3021 Configuration error on port 1
Servicer Response: FRU List: FCPORT Servicer Response: Too many devices have been configured on port 1. Change the configuration. FRU List: SVCDOCS 576B3100 Interface error on port 0
FCIOA
FCDEV
Servicer Response: FRU List: FCINTF OPT_CLN 576B3121 A port failure was detected on port 1
FCIOA
FCIOA
FCDEV
Servicer Response: FRU List: FCINTF OPT_CLN 576B3140 Port 0 is now operational
353
576B3141 576B8302
This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. FRU List: 576B3141 Port 1 is now operational 576B8150 A permanent I/O adapter failure occurred
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since the port is now operational. FRU List: 576B3400 Device error
ANYBRDG
FCINTF
ANYBRDG
ANYFC
PTFSRCH
FCIOA
OPT_CLN 576B8301 Format in progress Not valid condition in Licensed Internal Code
OPT_CLN 576B34FF
Servicer Response: The device indicated that a format is in progress. When the format is complete, the device should be usable. No action is required. This reference code is logged for information only. FRU List: 576B8130 Recovered Fibre Channel interface error on port 0
FCIOA
Servicer Response: No action required. This reference code is logged for information only. FRU List: 576B8131 Recovered Fibre Channel interface error on port 1
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
Servicer Response: No action required. This reference code is logged for information only. FRU List:
FCIOA
OPT_CLN
354
57743020 57743400
57743020 Configuration error on port 0
FCDEV
Servicer Response: Too many devices have been configured on port 0. Change the configuration. FRU List: SVCDOCS 57743021 Configuration error on port 1
Servicer Response: FRU List: FCPORT Servicer Response: Too many devices have been configured on port 1. Change the configuration. FRU List: SVCDOCS 57743100 Interface error on port 0
FCIOA
FCDEV
Servicer Response: FRU List: FCINTF OPT_CLN 57743140 Port 0 is now operational
ANYFC
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational. FRU List: 57743141 Interface error on port 1 Port 1 is now operational
FCIOA
OPT_CLN 57743101
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since the port is now operational. FRU List: 57743400 Device error
ANYFC
FCIOA
FCDEV
FCINTF
ANYFC
355
577434FF 57FC3100
577434FF Format in progress 57748301 Not valid condition in Licensed Internal Code
Servicer Response: The device indicated that a format is in progress. When the format is complete, the device should be usable. No action is required. This reference code is logged for information only. FRU List: 57748130 Recovered Fibre Channel interface error on port 0
FCIOA
Servicer Response: No action required. This reference code is logged for information only. FRU List: 57748131 Recovered Fibre Channel interface error on port 1
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
Servicer Response: No action required. This reference code is logged for information only. FRU List: 57748150 A permanent I/O adapter failure occurred
FCIOA
Servicer Response: FRU List: FCIOA Servicer Response: Too many devices have been configured on port 0. Change the configuration. FRU List: SVCDOCS 57FC3021 IOA hardware error or PCI bus error Configuration error on port 1
ANYBRDG
OPT_CLN 57748300
Servicer Response: Too many devices have been configured on port 1. Change the configuration. FRU List: SVCDOCS 57FC3100 Interface error on port 0
ANYBRDG
PTFSRCH
FCINTF
OPT_CLN
ANYFC
FCIOA
356
57FC3101 57FC8131
FRU List: OPT_CLN 57FC3101 Interface error on port 1 57FC3141 Port 1 is now operational
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action, since the port is now operational. FRU List: 57FC3400 Device error
ANYFC
FCIOA
FCDEV
FCINTF
ANYFC
Servicer Response: The device indicated that a format is in progress. When the format is complete, the device should be usable. No action is required. This reference code is logged for information only. FRU List: 57FC8130 Recovered Fibre Channel interface error on port 0
Servicer Response: No action required. This reference code is logged for information only. FRU List: 57FC8131 Recovered Fibre Channel interface error on port 1
FCIOA
FCDEV
Servicer Response: No action required. This reference code is logged for information only. FRU List:
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action, since the port is now operational.
357
57FC8150 571A3021
57FC8150 A permanent I/O adapter failure occurred 57FC8301 Not valid condition in Licensed Internal Code
ANYBRDG
FCIOA
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response:
358
571A3022 571A3122
STORIOA 571A3022 SCSI bus configuration error 571A3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 571A3103 571A3023 SCSI bus configuration error Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571A3100 Interface error Error occurred on SCSI bus 0. Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571A3120 Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571A3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571A3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571A3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
359
571A3123 571A8008
571A3123 Bus is not operational 571A3200 FRU List: FI01105 STORIOA MEDIA Bus is operational 571A3202 Storage subsystem configuration error A tape/CD or disk device reported a failure
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571A3140
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 571A3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 571A3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 571A3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 571A3401 FRU List: DEVBPLN 571A3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 571A3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 571A3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 571A3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH 571A3601 System log entry only, no service action required A permanent cache battery pack failure occurred
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS
571A8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the
360
571A8009 571A8157
Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA 571A8009 FRU List: CACHBAT 571A8100 FRU List: PTFSRCH STORIOA 571A8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 571A8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 571A8145 FRU List: STORIOA 571A8146 FRU List: FI01105 571A8150 A permanent failure occurred Disk device detected recoverable error A recoverable error occurred
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 571A8151 FRU List: PTFSRCH STORIOA 571A8155 FRU List: PTFSRCH STORIOA 571A8156 FRU List: PTFSRCH STORIOA 571A8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 571A8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 571A8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 571A8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 571A8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only.
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace
Chapter 6. 5xxx Reference Codes
361
571A8300 571A9020
the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources. FRU List: SVCDOCS 571A8300 FRU List: STORIOA ANYBRDG PTFSRCH 571A8301 FRU List: PTFSRCH STORIOA 571A8302 Missing Licensed Internal Code Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error 571A9001 Device configuration error.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 571A9002 Device error.
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 571A9008 I/O card does not support functions expected by devices.
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 571A9009 FRU List: SVCDOCS 571A9010 Cache data associated with attached devices cannot be found. Perform IOPIP31. Call your next level of support for assistance.
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA 571A8400 FRU List: PTFSRCH 571A8404 System log entry only, no service action required. Device error. Licensed Internal Code error
FRU List: SVCDOCS 571A9011 Cache data belongs to devices other than those attached.
Servicer Response: Perform IOPIP32. FRU List: SVCDOCS 571A9020 Array not functional due to present hardware configuration.
362
571A9021 571A9032
SVCDOCS 571A9021 Array not functional due to present hardware configuration. 571A9028 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS 571A9022 Array not functional due to present hardware configuration.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List: SVCDOCS 571A9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571A9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571A902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571A9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 571A9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571A9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 571A9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 571A9026 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 571A9032 A disk unit in a RAID array is missing or failed
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571A9027 Array not functional due to present hardware configuration.
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS
363
571A9040 571A9082
571A9040 Array protection temporarily suspended FRU List: SVCDOCS 571A9054 IOA resources not available due to previous problems
Servicer Response: No action required. Protection will be automatically restarted. 571A9041 Background array parity check detected and corrected errors.
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 571A9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 571A9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 571A9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 571A9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 571A9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 571A9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 571A9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 571A9081 FRU List: FI01105 STORIOA 571A9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571A9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them.
364
571A9090 571B3022
FI01106 571A9090 Disk unit has been modified after the last known status. 571AFF6D FRU List: STORIOA ANYBRDG PTFSRCH 571B3000 FRU List: FI01101 Incorrect hardware configuration change has been detected. ANYBRDG 571B3006 FRU List: FI01101 ANYBRDG PTFSRCH Disk unit requires initialization before use. 571B3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced, use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571A9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571A9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 571A9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571B3021 SCSI bus configuration error
571AC000
Servicer Response: No action is required. This reference code is logged for information only. 571AC402 Licensed Internal Code error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 571AFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
571B3022
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
Chapter 6. 5xxx Reference Codes
365
571B3023 571B3123
USER FI01107 STORIOA 571B3023 SCSI bus configuration error FI01140 BACKPLN 571B3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 571B3120 571B3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571B3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571B3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571B3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571B3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571B3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
366
571B3140 571B8008
571B3140 Bus is operational 571B3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 571B3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 571B3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 571B3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 571B3401 FRU List: DEVBPLN 571B3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 571B3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 571B3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 571B3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 571B3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
571B3601
System log entry only, no service action required A permanent cache battery pack failure occurred
571B8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
Chapter 6. 5xxx Reference Codes
367
571B8009 571B8157
571B8009 FRU List: CACHBAT 571B8100 FRU List: PTFSRCH STORIOA 571B8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 571B8146 FRU List: FI01105 571B8150 A permanent failure occurred. Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 571B8151 FRU List: PTFSRCH STORIOA 571B8155 FRU List: PTFSRCH STORIOA 571B8156 FRU List: PTFSRCH STORIOA 571B8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 571B8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 571B8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 571B8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 571B8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 571B8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 571B8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
368
571B8300 571B9021
FRU List: SVCDOCS 571B8300 FRU List: STORIOA ANYBRDG PTFSRCH 571B8301 FRU List: PTFSRCH STORIOA 571B8302 Missing Licensed Internal Code FRU List: SVCDOCS 571B9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 571B9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 571B9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 571B9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 571B9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 571B9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 571B9002 Device error
369
571B9022 571B9040
571B9022 Array not functional due to present hardware configuration. SVCDOCS 571B9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571B9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571B902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571B9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 571B9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571B9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 571B9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 571B9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571B9027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 571B9032 A disk unit in a RAID array is missing or failed
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 571B9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 571B9028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
370
571B9041 571B9082
571B9041 Background array parity check detected and corrected errors. 571B9054 IOA resources not available due to previous problems
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 571B9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 571B9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 571B9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 571B9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 571B9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 571B9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 571B9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 571B9081 FRU List: FI01105 STORIOA 571B9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571B9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS
371
571B9090 571E3022
571B9090 Disk unit has been modified after the last known status. 571BFF6D FRU List: STORIOA ANYBRDG PTFSRCH 571E3000 Incorrect hardware configuration change has been detected. FRU List: FI01101 ANYBRDG 571E3006 FRU List: FI01101 ANYBRDG Disk unit requires initialization before use. PTFSRCH 571E3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571B9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571B9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 571B9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571E3021 SCSI bus configuration error
571BC000
Servicer Response: No action is required. This reference code is logged for information only. 571BC402 Licensed Internal Code error
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 571BFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571E3022 SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
372
571E3023 571E3123
USER FI01107 STORIOA 571E3023 SCSI bus configuration error FI01140 BACKPLN 571E3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 571E3120 571E3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571E3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571E3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571E3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571E3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571E3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
373
571E3140 571E8008
571E3140 Bus is operational 571E3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 571E3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 571E3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 571E3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 571E3401 FRU List: DEVBPLN 571E3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 571E3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 571E3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 571E3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 571E3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
571E3601
System log entry only, no service action required A permanent cache battery pack failure occurred
571E8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
374
571E8009 571E8157
571E8009 FRU List: CACHBAT 571E8100 FRU List: PTFSRCH STORIOA 571E8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 571E8146 FRU List: FI01105 571E8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 571E8151 FRU List: PTFSRCH STORIOA 571E8155 FRU List: PTFSRCH STORIOA 571E8156 FRU List: PTFSRCH STORIOA 571E8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 571E8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 571E8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 571E8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 571E8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 571E8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 571E8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
Chapter 6. 5xxx Reference Codes
375
571E8300 571E9021
FRU List: SVCDOCS 571E8300 FRU List: STORIOA ANYBRDG PTFSRCH 571E8301 FRU List: PTFSRCH STORIOA 571E8302 Missing Licensed Internal Code FRU List: SVCDOCS 571E9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 571E9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 571E9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 571E9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 571E9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 571E9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 571E9002 Device error
376
571E9022 571E9040
571E9022 Array not functional due to present hardware configuration. SVCDOCS 571E9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571E9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571E902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571E9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 571E9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571E9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 571E9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 571E9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571E9027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 571E9032 A disk unit in a RAID array is missing or failed
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 571E9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 571E9028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
377
571E9041 571E9082
571E9041 Background array parity check detected and corrected errors. 571E9054 IOA resources not available due to previous problems
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 571E9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 571E9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 571E9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 571E9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 571E9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 571E9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 571E9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 571E9081 FRU List: FI01105 STORIOA 571E9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571E9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS
378
571E9090 571F3022
571E9090 Disk unit has been modified after the last known status. 571EFF6D FRU List: STORIOA ANYBRDG PTFSRCH 571F3000 Incorrect hardware configuration change has been detected. FRU List: FI01101 ANYBRDG 571F3006 FRU List: FI01101 ANYBRDG Disk unit requires initialization before use. PTFSRCH 571F3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571E9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571E9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 571E9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571F3021 SCSI bus configuration error
571EC000
Servicer Response: No action is required. This reference code is logged for information only. 571EC402 Licensed Internal Code error
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 571EFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 571F3022 SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
Chapter 6. 5xxx Reference Codes
379
571F3023 571F3123
USER FI01107 STORIOA 571F3023 SCSI bus configuration error FI01140 BACKPLN 571F3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 571F3120 571F3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571F3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571F3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571F3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 571F3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 571F3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
380
571F3140 571F8008
571F3140 Bus is operational 571F3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 571F3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 571F3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 571F3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 571F3401 FRU List: DEVBPLN 571F3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 571F3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 571F3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 571F3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 571F3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
571F3601
System log entry only, no service action required A permanent cache battery pack failure occurred
571F8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
Chapter 6. 5xxx Reference Codes
381
571F8009 571F8157
571F8009 FRU List: CACHBAT 571F8100 FRU List: PTFSRCH STORIOA 571F8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 571F8146 FRU List: FI01105 571F8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 571F8151 FRU List: PTFSRCH STORIOA 571F8155 FRU List: PTFSRCH STORIOA 571F8156 FRU List: PTFSRCH STORIOA 571F8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 571F8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 571F8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 571F8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 571F8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 571F8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 571F8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
382
571F8300 571F9021
FRU List: SVCDOCS 571F8300 FRU List: STORIOA ANYBRDG PTFSRCH 571F8301 FRU List: PTFSRCH STORIOA 571F8302 Missing Licensed Internal Code FRU List: SVCDOCS 571F9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 571F9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 571F9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 571F9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 571F9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 571F9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 571F9002 Device error
383
571F9022 571F9040
571F9022 Array not functional due to present hardware configuration. SVCDOCS 571F9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571F9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571F902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571F9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 571F9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571F9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 571F9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 571F9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 571F9027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 571F9032 A disk unit in a RAID array is missing or failed
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 571F9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 571F9028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
384
571F9041 571F9082
571F9041 Background array parity check detected and corrected errors. 571F9054 IOA resources not available due to previous problems
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 571F9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 571F9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 571F9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 571F9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 571F9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 571F9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 571F9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 571F9081 FRU List: FI01105 STORIOA 571F9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 571F9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS
385
571F9090 573D3022
571F9090 Disk unit has been modified after the last known status. 571FFF6D FRU List: STORIOA ANYBRDG PTFSRCH 573D3000 Incorrect hardware configuration change has been detected. FRU List: FI01101 ANYBRDG 573D3006 FRU List: FI01101 ANYBRDG Disk unit requires initialization before use. PTFSRCH 573D3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571F9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 571F9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 571F9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 573D3021 SCSI bus configuration error
571FC000
Servicer Response: No action is required. This reference code is logged for information only. 571FC402 Licensed Internal Code error
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 571FFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 573D3022 SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
386
573D3023 573D3123
USER FI01107 STORIOA 573D3023 SCSI bus configuration error FI01140 BACKPLN 573D3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 573D3120 573D3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 573D3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573D3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573D3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 573D3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573D3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
387
573D3140 573D8008
573D3140 Bus is operational 573D3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 573D3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 573D3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 573D3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 573D3401 FRU List: DEVBPLN 573D3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 573D3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 573D3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 573D3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 573D3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
573D3601
System log entry only, no service action required A permanent cache battery pack failure occurred
573D8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
388
573D8009 573D8157
573D8009 FRU List: CACHBAT 573D8100 FRU List: PTFSRCH STORIOA 573D8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 573D8146 FRU List: FI01105 573D8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 573D8151 FRU List: PTFSRCH STORIOA 573D8155 FRU List: PTFSRCH STORIOA 573D8156 FRU List: PTFSRCH STORIOA 573D8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 573D8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 573D8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 573D8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 573D8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 573D8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 573D8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
Chapter 6. 5xxx Reference Codes
389
573D8300 573D9021
FRU List: SVCDOCS 573D8300 FRU List: STORIOA ANYBRDG PTFSRCH 573D8301 FRU List: PTFSRCH STORIOA 573D8302 Missing Licensed Internal Code FRU List: SVCDOCS 573D9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 573D9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 573D9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 573D9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 573D9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 573D9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 573D9002 Device error
390
573D9022 573D9040
573D9022 Array not functional due to present hardware configuration. SVCDOCS 573D9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573D9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 573D902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573D9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 573D9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573D9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 573D9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 573D9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573D9027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 573D9032 A disk unit in a RAID array is missing or failed
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 573D9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 573D9028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
391
573D9041 573D9082
573D9041 Background array parity check detected and corrected errors. 573D9054 IOA resources not available due to previous problems
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 573D9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 573D9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 573D9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 573D9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 573D9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 573D9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 573D9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 573D9081 FRU List: FI01105 STORIOA 573D9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 573D9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS
392
573D9090 573E3022
573D9090 Disk unit has been modified after the last known status. 573DFF6D FRU List: STORIOA ANYBRDG PTFSRCH 573E3000 Incorrect hardware configuration change has been detected. FRU List: FI01101 ANYBRDG 573E3006 FRU List: FI01101 ANYBRDG Disk unit requires initialization before use. PTFSRCH 573E3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 573D9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 573D9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 573D9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 573E3021 SCSI bus configuration error
573DC000
Servicer Response: No action is required. This reference code is logged for information only. 573DC402 Licensed Internal Code error
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 573DFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 573E3022 SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
Chapter 6. 5xxx Reference Codes
393
573E3023 573E3123
USER FI01107 STORIOA 573E3023 SCSI bus configuration error FI01140 BACKPLN 573E3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN
STORIOA 573E3120 573E3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 573E3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573E3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573E3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 BACKPLN 573E3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 573E3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
394
573E3140 573E8008
573E3140 Bus is operational 573E3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 573E3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 573E3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 573E3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 573E3401 FRU List: DEVBPLN 573E3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 573E3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 573E3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 573E3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 573E3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
573E3601
System log entry only, no service action required A permanent cache battery pack failure occurred
573E8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
Chapter 6. 5xxx Reference Codes
395
573E8009 573E8157
573E8009 FRU List: CACHBAT 573E8100 FRU List: PTFSRCH STORIOA 573E8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 573E8146 FRU List: FI01105 573E8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 573E8151 FRU List: PTFSRCH STORIOA 573E8155 FRU List: PTFSRCH STORIOA 573E8156 FRU List: PTFSRCH STORIOA 573E8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 573E8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 573E8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 573E8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 573E8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 573E8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 573E8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
396
573E8300 573E9021
FRU List: SVCDOCS 573E8300 FRU List: STORIOA ANYBRDG PTFSRCH 573E8301 FRU List: PTFSRCH STORIOA 573E8302 Missing Licensed Internal Code FRU List: SVCDOCS 573E9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 573E9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 573E9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 573E9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 573E9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 573E9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 573E9002 Device error
397
573E9022 573E9040
573E9022 Array not functional due to present hardware configuration. SVCDOCS 573E9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573E9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 573E902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573E9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 573E9030 Array no longer protected due to missing or failed disk unit.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573E9025 Disk unit is not supported at its physical location.
Servicer Response: Perform isolation procedure IOPIP21. To review isolation procedure IOPIP21, go to your host servers service guide. FRU List: FI02112 SVCDOCS 573E9031 Array protection temporarily suspended
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 573E9026 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 573E9027 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 573E9032 A disk unit in a RAID array is missing or failed
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 573E9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 573E9028 Incorrect hardware configuration change has been detected.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
398
573E9041 573E9082
573E9041 Background array parity check detected and corrected errors 573E9054 IOA resources not available due to previous problems
Servicer Response: Call your next level of support to report the problem. FRU List: PTFSRCH 573E9042 An array parity error has been detected and corrected
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 573E9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 573E9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 573E9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 573E9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 573E9073 Incompatible or non-operational auxiliary cache IOA attached.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 573E9052 Cache data exists for device that has been modified.
Servicer Response: Perform isolation procedure IOPIP40. To review isolation procedure IOPIP40, go to your host servers service guide. FRU List: SVCDOCS 573E9081 FRU List: FI01105 STORIOA 573E9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 573E9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS
399
573E9090 57FF3022
573E9090 Disk unit has been modified after the last known status. 573EFF6D FRU List: STORIOA ANYBRDG PTFSRCH 57FF3000 Incorrect hardware configuration change has been detected. FRU List: FI01101 ANYBRDG 57FF3006 FRU List: FI01101 ANYBRDG Disk unit requires initialization before use. PTFSRCH 57FF3020 SCSI bus configuration error System bus error A permanent failure occurred Recoverable system bus error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 573E9091
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 573E9092
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 573E9902 System log entry only, no service action required System log entry only, no service action required
Servicer Response: Error occurred on SCSI bus 0. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 57FF3021 SCSI bus configuration error
573EC000
Servicer Response: No action is required. This reference code is logged for information only. 573EC402 Licensed Internal Code error
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 573EFF3D FRU List: STORIOA ANYBRDG I/O adapter detected a recoverable error
Servicer Response: Error occurred on SCSI bus 1. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107 STORIOA 57FF3022 SCSI bus configuration error
Servicer Response: Error occurred on SCSI bus 2. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List:
400
57FF3023 57FF3123
USER FI01107 STORIOA 57FF3023 SCSI bus configuration error FI01140 DEVBPLN 57FF3103 Interface error Error occurred on SCSI bus 3.
Servicer Response: Error occurred on SCSI bus 3. To correct or isolate a possible user error or configuration error, perform IOPIP17. FRU List: USER FI01107
Servicer Response: Error occurred on SCSI bus 3. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN
STORIOA 57FF3120 57FF3100 Interface error Error occurred on SCSI bus 0. Bus is not operational
Servicer Response: Error occurred on SCSI bus 0. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 57FF3101 Interface error Error occurred on SCSI bus 1.
Servicer Response: Adding a device to SCSI bus 0 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57FF3121 Bus is not operational
Servicer Response: Adding a device to SCSI bus 1 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57FF3122 Bus is not operational
Servicer Response: Error occurred on SCSI bus 1. Perform IOPIP13. FRU List: FI01107 STORIOA FI01140 DEVBPLN 57FF3102 Interface error Error occurred on SCSI bus 2.
Servicer Response: Adding a device to SCSI bus 2 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS 57FF3123 Bus is not operational
Servicer Response: Error occurred on SCSI bus 2. Perform IOPIP13. FRU List: FI01107 STORIOA
Servicer Response: Adding a device to SCSI bus 3 of the I/O Adapter caused the bus to become not operational. Remove the device. FRU List: SVCDOCS
401
57FF3140 57FF8008
57FF3140 Bus is operational 57FF3202 Storage subsystem configuration error
Servicer Response: This reference code and the 3120 reference code that occurred before it require no service action because SCSI bus 0 is now operational. 57FF3141 Bus is operational
Servicer Response: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 57FF3400 Device error
Servicer Response: This reference code and the 3121 reference code that occurred before it require no service action because SCSI bus 1 is now operational. 57FF3142 Bus is operational
Servicer Response: NOTE: If external devices are attached check EXTSCSI and DEVTERM first. FRU List: FI02112 STORIOA FI01106 FI01140 57FF3401 FRU List: DEVBPLN 57FF3501 Licensed Internal Code error Device backplane problem
Servicer Response: This reference code and the 3122 reference code that occurred before it require no service action because SCSI bus 2 is now operational. 57FF3143 Bus is operational
Servicer Response: This reference code and the 3123 reference code that occurred before it require no service action because SCSI bus 3 is now operational. 57FF3150 SCSI bus configuration error
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 0 at the same time. Correct the SCSI bus 0 configuration. FRU List: SVCDOCS 57FF3151 SCSI bus configuration error
Servicer Response: The device type is either unsupported or the code has not been loaded to support it. FRU List: FI01105 PTFSRCH
Servicer Response: Internal and external SCSI cables are connected to SCSI bus 1 at the same time. Correct the SCSI bus 1 configuration. FRU List: SVCDOCS 57FF3200 FRU List: FI01105 STORIOA MEDIA A tape/CD or disk device reported a failure
57FF3601
System log entry only, no service action required A permanent cache battery pack failure occurred
57FF8008
Servicer Response:: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT STORIOA
402
57FF8009 57FF8157
57FF8009 FRU List: CACHBAT 57FF8100 FRU List: PTFSRCH STORIOA 57FF8130 IOA detected recoverable device bus error Licensed Internal Code error Impending cache battery pack failure 57FF8146 FRU List: FI01105 57FF8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response:: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA ANYBRDG 57FF8151 FRU List: PTFSRCH STORIOA 57FF8155 FRU List: PTFSRCH STORIOA 57FF8156 FRU List: PTFSRCH STORIOA 57FF8157 I/O adapter card error A permanent failure occurred A permanent failure occurred Licensed Internal Code error
Servicer Response: An error occurred on SCSI bus 0. No action is required. This reference code is logged for information only. 57FF8131 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 1. No action is required. This reference code is logged for information only. 57FF8132 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 2. No action is required. This reference code is logged for information only. 57FF8133 IOA detected recoverable device bus error
Servicer Response: An error occurred on SCSI bus 3. No action is required. This reference code is logged for information only. 57FF8140 IOA detected recoverable device bus error
Servicer Response: No action is required. This reference code is logged for information only. 57FF8141 IOA detected recoverable device error
Servicer Response: No action is required. This reference code is logged for information only. 57FF8145 FRU List: STORIOA A recoverable error occurred
Servicer Response: Display the Service Action Log entry for this SRC. If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Perform the following for the I/O processor that the I/O adapter is attached to: 1. If the I/O processor is not operable and disk units are attached, use Hardware Service Manager to re-IPL the IOP. Other resources attached to the IOP may then need to be Varied On. 2. If disk units are not attached, perform the VRYCFG RESET(*YES) command to reset the IOP and Vary On attached resources.
Chapter 6. 5xxx Reference Codes
403
57FF8300 57FF9021
FRU List: SVCDOCS 57FF8300 FRU List: STORIOA ANYBRDG PTFSRCH 57FF8301 FRU List: PTFSRCH STORIOA 57FF8302 Missing Licensed Internal Code FRU List: SVCDOCS 57FF9010 Cache data associated with attached devices cannot be found Perform IOPIP31. Not valid condition in Licensed Internal Code IOA hardware error or PCI bus error STORIOA FI01140 BACKPLN FI01106 57FF9008 I/O card does not support functions expected by devices
Servicer Response: Perform IOPIP25. FRU List: SVCDOCS 57FF9009 Call your next level of support for assistance
Servicer Response: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS STORIOA
FRU List: SVCDOCS 57FF9011 Cache data belongs to devices other than those attached
Servicer Response: Perform IOPIP32. System log entry only, no service action required Device error FRU List: SVCDOCS 57FF9020 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP20. FRU List: SVCDOCS Device configuration error 57FF9021 Array not functional due to present hardware configuration.
Servicer Response: Perform IOPIP33. FRU List: SVCDOCS 57FF9002 Device error
404
57FF9022 57FF9041
57FF9022 Array not functional due to present hardware configuration. SVCDOCS 57FF9029 Incorrect hardware configuration change has been detected.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57FF9023 Array not functional due to present hardware configuration.
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57FF902F Array addendum Product Activity Log entry
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57FF9024 Array not functional due to present hardware configuration.
Servicer Response: This entry contains additional array information for 90xx reference codes when the array contains more than 10 members. Use the 90xx entry that occurred at the same time as this reference code as the starting point for this problem. 57FF9030 Array no longer protected due to missing or failed disk unit. Perform IOPIP21.
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57FF9025 Disk unit is not supported at its physical location.
Servicer Response: Perform IOPIP21. FRU List: SVCDOCS 57FF9026 Array not functional due to present hardware configuration.
Servicer Response: No action required. Protection will be automatically restarted. 57FF9032 A disk unit in a RAID array is missing or failed
Servicer Response: Perform IOPIP22. FRU List: SVCDOCS 57FF9027 Array not functional due to present hardware configuration.
Servicer Response: The array is still protected, but the disk unit should be replaced. Perform IOPIP21. FRU List: FI02112 SVCDOCS 57FF9040 Array protection temporarily suspended
Servicer Response: Perform IOPIP34. FRU List: SVCDOCS 57FF9028 Incorrect hardware configuration change has been detected.
Servicer Response: No action required. Protection will be automatically restarted. 57FF9041 Background array parity check detected and corrected errors Call your next level of support to report the problem.
Servicer Response: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List:
405
57FF9042 57FF9090
57FF9042 An array parity error has been detected and corrected FRU List: SVCDOCS 57FF9071 Link from IOA to auxiliary cache IOA went operational
Servicer Response: Call your next level of support to report the problem. FRU List: NEXTLVL 57FF9050 Required cache data cannot be located for a disk unit.
Servicer Response: No service action required. 57FF9072 Link from IOA to auxiliary cache IOA went non-operational
Servicer Response: Perform IOPIP30. FRU List: SVCDOCS 57FF9051 Cache data exists for a missing or failed device
Servicer Response: No service action required. 57FF9073 Incompatible or non-operational auxiliary cache IOA attached. Perform IOPIP40.
Servicer Response: If all configured units are missing, a 9054 reference code may appear in the product activity log. If so, perform the action indicated for the 9054 reference code.Otherwise, perform IOPIP27. FRU List: SVCDOCS 57FF9052 Cache data exists for device that has been modified.
FRU List: SVCDOCS 57FF9081 FRU List: FI01105 STORIOA 57FF9082 Device error Device error
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 57FF9053 IOA resources not available due to previous problems
Servicer Response: Perform IOPIP16. FRU List: FI01105 STORIOA FI01140 BACKPLN FI01106 57FF9090 Disk unit has been modified after the last known status.
Servicer Response: Take action on other reference codes which have surfaced.If you cannot get to SST or DST, and cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them. FRU List: SVCDOCS 57FF9054 IOA resources not available due to previous problems
Servicer Response: Power off the system and remove all new or replacement disk units. IPL the system to DST. If you cannot perform a type A or B IPL, perform a type D IPL from removable media. Look for Product Activity Log entries for other reference codes and take action on them.
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
406
57FF9091 572A3400
57FF9091 Incorrect hardware configuration change has been detected. No action is required. This reference code is logged for information only. 57FFC402 Licensed Internal Code error
Servicer Response: Re-IPL the system. If any reference codes are surfaced use the new reference code as the entry point to the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 57FF9092 Disk unit requires initialization before use.
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 57FFFF3D FRU List: STORIOA ANYBRDG 57FFFF6D Recoverable system bus error I/O adapter detected a recoverable error
Servicer Response: Perform IOPIP26. FRU List: SVCDOCS 57FF9902 System log entry only, no service action required System log entry only, no service action required
57FFC000
PTFSRCH
Servicer Response:
Servicer: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 572A3000 FRU List: STORIOA A permanent failure occurred
Servicer: The device is not supported in the current configuration. An I/O processor might be required. FRU List:
ANYBRDG 572A3020 FRU List: SIP3150 572A3100 FRU List: Device bus interface error occurred Storage subsystem configuration error
407
572A3401 572A4101
STORIOA SASCABL 572A3401 FRU List: SASEXP 572A4050 DEVBPLN 572A34FF Format in progress FRU List: SIP3148 572A4060 Multipath redundancy level reduced Enclosure does not support required multipath function Device backplane problem 572A4041 Incomplete multipath connection
Servicer: Incomplete multipath connection between device backplane and device. FRU List: SIP3146
Servicer: No action required. This reference code is logged for information only. 572A3601 Format in progress
Servicer: A redundant disk unit connection has failed. FRU List: SIP3153 SASCABL SASEXP 572A4061 Multipath redundancy level increased
Servicer: System log entry only, no service action required 572A4010 Configuration error
Servicer: Incorrect connection between cascaded enclosures. FRU List: SIP3142 572A4020 Configuration error
Servicer: A redundant disk unit connection has been restored. No service action is required. 572A4070 System log entry only.
Servicer: Number of connections exceed I/O adapter design limits. FRU List: SIP3143 572A4030 Configuration error
Servicer: No service action required. 572A4100 FRU List: SIP3152 SASCABL SASEXP DEVBPLN Device bus fabric error
Servicer: Incorrect multipath connection. FRU List: SIP3144 572A4040 Configuration error
STORIOA
Servicer: Incomplete multipath connection between I/O adapter and enclosure. FRU List: SIP3144
FI01105 572A4101 FRU List: SIP3152 Temporary device bus fabric error
408
572A4110 572A8150
572A4110 FRU List: CACHBAT SIP3145 572A8100 572A4150 I/O adapter detected PCI bus error FRU List: PTFSRCH Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: 572A8130 BACKPLN IOA detected recoverable device bus error Licensed Internal Code error Unsupported enclosure function detected 572A8009 FRU List: Impending cache battery pack failure
STORIOA
STORIOA 572A4160 I/O adapter detected and recovered a PCI bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: SIP3150 572A8140 IOA detected recoverable device bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: BACKPLN
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: SIP3150 A permanent cache battery pack failure occurred 572A8141 IOA detected recoverable device error
STORIOA 572A8008
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT
Servicer: No action is required. This reference code is logged for information only. 572A8146 FRU List: FI01105 572A8150 A permanent failure occurred Disk device detected recoverable error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load
STORIOA
409
572A8151 572A9002
Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA PTFSRCH 572A8301 FRU List: PTFSRCH 572A8151 FRU List: PTFSRCH 572A8302 STORIOA 572A8155 FRU List: SVCDOCS PTFSRCH STORIOA STORIOA 572A8400 572A8156 FRU List: PTFSRCH PTFSRCH 572A8404 STORIOA 572A8157 I/O adapter card error 572A9000 FRU List: FI01105 Device error System log entry only. A permanent failure occurred FRU List: Licensed Internal Code error A permanent failure occurred Missing Licensed Internal Code Servicer: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: Licensed Internal Code error STORIOA Not valid condition in Licensed Internal Code
ANYBRDG
Servicer: Display the Service Action Log entry for this SRC.If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. FRU List: SVCDOCS 572A8300 FRU List: STORIOA IOA hardware error or PCI bus error
STORIOA 572A9001 FRU List: NEXTLVL 572A9002 FRU List: NEXTLVL Device error Device configuration error
ANYBRDG
410
572A9008 572A9029
572A9008 FRU List: SIP3130 572A9010 FRU List: SIP3120 572A9011 FRU List: NEXTLVL NEXTLVL 572A9020 FRU List: SIP3111 572A9021 FRU List: SIP3111 572A9022 FRU List: SIP3111 572A9023 FRU List: SIP3112 572A9024 FRU List: NEXTLVL Array member physical location conflicts with another array One or more array members not in required physical locations Two or more disk units missing from RAID-5 or RAID-6 array Two or more disk units missing from RAID-5 or RAID-6 array Two or more disk units missing from RAID-5 or RAID-6 array 572A9027 Array not functional due to parity out of synchronization Cache data belongs to devices other than those attached Cache data associated with attached devices cannot be found I/O card does not support functions expected by devices 572A9025 Incompatible device
Servicer: An incompatible device is at the physical location of the device which is causing the array to be exposed. FRU List: SIP3110 FI02112 572A9026 Disk unit not found at required physical location
Servicer: A previously exposed disk unit in an array was not found at the required physical location. FRU List:
Servicer: Array is or would become exposed and parity data is out of synchronization FRU List: SIP3113 572A9028 Maximum number of functional arrays has been exceeded
Servicer: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List: SVCDOCS SIP3113 572A9029 Maximum number of functional array members has been exceeded
Servicer: Contact your next level of support. FRU List: NEXTLVL SIP3113
411
572A9030 572A9074
572A9030 FRU List: SIP3110 FI02112 572A9031 Automatic rebuild initiated for array Array no longer protected due to missing or failed disk unit SIP3131 572A9051 FRU List: SIP3132 572A9052 Cache data exists for one or more modified devices Cache data exists for one or more missing or failed devices
Servicer: Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them. 572A9032 A disk unit in an array is missing or failed
Servicer: Contact your next level of support. FRU List: NEXTLVL 572A9054 FRU List: SIP3121 572A9070 System log entry only. IOA resources not available due to previous problems
Servicer: The array is still protected, but the disk unit should be replaced. FRU List: SIP3110 FI02112 572A9040 Resynchronization of array parity was initiated
Servicer: No service action required. 572A9071 Link from IOA to auxiliary or remote IOA is operational
Servicer: No action required. 572A9041 Background array parity check detected and corrected errors
Servicer: No service action required. 572A9072 Link from IOA to auxiliary or remote IOA is non-operational
Servicer: Call your next level of support to report the problem. FRU List: NEXTLVL 572A9042 Background parity check corrected errors on disk unit
Servicer: No service action required. 572A9073 FRU List: SIP3140 572A9074 Multiple I/O adapters connected in a not valid configuration Multiple I/O adapters connected in a not valid configuration
Servicer: Call your next level of support to report the problem. FRU List: NEXTLVL 572A9050 FRU List: Required cache data not found for one or more disk units
Servicer: Multiple I/O adapters not capable of similar functions or controlling the same set of devices. FRU List: SIP3141
412
572A9075 572C3020
572A9075 FRU List: SIP3149 572A9076 FRU List: SIP3147 572A9081 FRU List: FI01105 572AC402 STORIOA 572A9082 FRU List: FI01105 572AFF3D STORIOA 572A9090 Disk unit has been modified after the last known status. FRU List: STORIOA I/O adapter detected a recoverable error Device error Licensed Internal Code error Device error Missing auxiliary IOA or remote IOA Incomplete multipath connection between IOA and remote IOA SVCDOCS 572A9092 FRU List: SIP3134 572AC000 System log entry only, no service action required Disk unit requires initialization before use.
Servicer: No action is required. This reference code is logged for information only.
Servicer: Ask your next level of support for assistance.. FRU List: PTFSRCH
Servicer: Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. If any reference codes are surfaced, use the new reference code to resolve the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS
Servicer: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 572C3000 FRU List: STORIOA A permanent failure occurred
572A9091
Servicer: Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. If any reference codes are surfaced, use the new reference code to resolve the problem. If you cannot resolve the problem, contact your next level of support. FRU List:
413
572C3100 572C4061
572C3100 FRU List: SIP3150 572C3140 System log entry only. Device bus interface error occurred 572C4020 Configuration error
Servicer: Number of connections exceed I/O adapter design limits. FRU List: SIP3143 572C4030 Configuration error
Servicer: Incorrect multipath connection. FRU List: SIP3144 572C4040 Configuration error
Servicer: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 572C3400 FRU List: SIP3150 FI02112 Unknown resource error
Servicer: Incomplete multipath connection between I/O adapter and enclosure. FRU List: SIP3144 572C4041 Incomplete multipath connection
Servicer: Incomplete multipath connection between device backplane and device. FRU List: SIP3146 572C4050 FRU List: SIP3148 572C4060 Format in progress Multipath redundancy level reduced Enclosure does not support required multipath function
STORIOA SASCABL 572C3401 FRU List: SASEXP DEVBPLN 572C34FF Device backplane problem
Servicer: A redundant disk unit connection has failed. FRU List: SIP3153 SASCABL SASEXP 572C4061 Multipath redundancy level increased
Servicer: No action required. This reference code is logged for information only. 572C3601 Format in progress
Servicer: System log entry only, no service action required 572C4010 Configuration error
Servicer: A redundant disk unit connection has been restored. No service action is required.
414
572C4070 572C8140
572C4070 System log entry only. BACKPLN
Servicer: No service action required. 572C4100 FRU List: SIP3152 SASCABL SASEXP DEVBPLN Device bus fabric error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT 572C4101 FRU List: SIP3152 572C8009 572C4110 FRU List: SIP3145 572C4150 I/O adapter detected PCI bus error PTFSRCH Unsupported enclosure function detected FRU List: CACHBAT 572C8100 FRU List: Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: BACKPLN Licensed Internal Code error Impending cache battery pack failure Temporary device bus fabric error STORIOA
STORIOA
FI01105
STORIOA 572C4160 I/O adapter detected and recovered a PCI bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: SIP3150 572C8140 IOA detected recoverable device bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List:
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required.
Chapter 6. 5xxx Reference Codes
415
572C8141 572C8400
FRU List: SIP3150 572C8141 IOA detected recoverable device error 572C8157 I/O adapter card error
Servicer: No action is required. This reference code is logged for information only. 572C8146 FRU List: FI01105 572C8150 A permanent failure occurred Disk device detected recoverable error
Servicer: Display the Service Action Log entry for this SRC.If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. FRU List: SVCDOCS
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA
ANYBRDG
PTFSRCH 572C8301 FRU List: Not valid condition in Licensed Internal Code
ANYBRDG PTFSRCH 572C8151 FRU List: PTFSRCH Licensed Internal Code error STORIOA 572C8302 Missing Licensed Internal Code
Servicer: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
STORIOA STORIOA 572C8400 572C8156 FRU List: PTFSRCH A permanent failure occurred FRU List: PTFSRCH Licensed Internal Code error
STORIOA
416
572C8404 572C9028
572C8404 System log entry only. 572C9022 FRU List: SIP3111 572C9023 FRU List: STORIOA 572C9001 FRU List: FRU List: NEXTLVL NEXTLVL 572C9002 FRU List: NEXTLVL 572C9008 FRU List: SIP3130 572C9010 FRU List: SIP3120 572C9011 FRU List: NEXTLVL 572C9020 FRU List: SIP3111 572C9021 FRU List: SIP3111
Chapter 6. 5xxx Reference Codes
Servicer: No service action required. 572C9000 FRU List: FI01105 Device error
SIP3112 Device configuration error 572C9024 Array member physical location conflicts with another array
Device error 572C9025 Incompatible device Servicer: An incompatible device is at the physical location of the device which is causing the array to be exposed. I/O card does not support functions expected by devices FRU List: SIP3110 FI02112 572C9026 Disk unit not found at required physical location
Servicer: A previously exposed disk unit in an array was not found at the required physical location. FRU List: Cache data belongs to devices other than those attached NEXTLVL 572C9027 Array not functional due to parity out of synchronization
Servicer: Array is or would become exposed and parity data is out of synchronization FRU List: SIP3113 572C9028 Servicer: Maximum number of functional arrays has been exceeded
417
572C9029 572C9070
Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. FRU List: SVCDOCS NEXTLVL SIP3113 572C9042 572C9029 Maximum number of functional array members has been exceeded Background parity check corrected errors on disk unit 572C9041 Background array parity check detected and corrected errors
Servicer: Call your next level of support to report the problem. FRU List:
Servicer: Call your next level of support to report the problem. FRU List: NEXTLVL
NEXTLVL SIP3113 572C9030 FRU List: SIP3110 FI02112 572C9031 Automatic rebuild initiated for array 572C9051 FRU List: SIP3132 572C9052 Cache data exists for one or more modified devices Cache data exists for one or more missing or failed devices Array no longer protected due to missing or failed disk unit 572C9050 FRU List: SIP3131 Required cache data not found for one or more disk units
Servicer: Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them. 572C9032 A disk unit in an array is missing or failed
Servicer: Contact your next level of support. FRU List: NEXTLVL 572C9054 FRU List: SIP3121 572C9070 System log entry only. IOA resources not available due to previous problems
Servicer: The array is still protected, but the disk unit should be replaced. FRU List: SIP3110 FI02112 572C9040 Resynchronization of array parity was initiated
418
572C9071 572CC402
572C9071 Link from IOA to auxiliary or remote IOA is operational 572C9090 Disk unit has been modified after the last known status.
Servicer: No service action required. 572C9072 Link from IOA to auxiliary or remote IOA is non-operational
Servicer: Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. If any reference codes are surfaced, use the new reference code to resolve the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 572C9091 Incorrect hardware configuration change has been detected.
Servicer: No service action required. 572C9073 FRU List: SIP3140 572C9074 Multiple I/O adapters connected in a not valid configuration Multiple I/O adapters connected in a not valid configuration
Servicer: Multiple I/O adapters not capable of similar functions or controlling the same set of devices. FRU List: SIP3141 572C9075 FRU List: SIP3149 572C9076 FRU List: SIP3147 572C9081 FRU List: FI01105 Device error Missing auxiliary IOA or remote IOA Incomplete multipath connection between IOA and remote IOA
Servicer: Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. If any reference codes are surfaced, use the new reference code to resolve the problem. If you cannot resolve the problem, contact your next level of support. FRU List: SVCDOCS 572C9092 FRU List: SIP3134 572CC000 System log entry only, no service action required Disk unit requires initialization before use.
Servicer: No action is required. This reference code is logged for information only. 572CC402 Licensed Internal Code error
Servicer: Ask your next level of support for assistance.. FRU List: PTFSRCH
STORIOA
419
572CFF3D 573CA6D9
572CFF3D FRU List: STORIOA I/O adapter detected a recoverable error
ANYBRDG
420
573CA6E3 57B78008
573CA6E3 FRU List: FI00722 UJE40 IOA 573CB100 FRU List: IOA AJDG301 I/O adapter hardware error detected 573CB300 FRU List: IOA AJDG301 I/O adapter hardware error detected Ethernet adapter or network device cabling error. 573CB200 FRU List: AJDG301 IOA I/O adapter hardware error detected
Servicer: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them.
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: BACKPLN
PRIMIOA AUXIOA AUXIOA 57B78008 BACKPLN 57B74150 Servicer: I/O adapter detected PCI bus error A permanent cache battery pack failure occurred.
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow
Chapter 6. 5xxx Reference Codes
421
57B78009 57B78157
attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: 57B78150 CACHBAT A permanent failure occurred Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: AUXIOA
BACKPLN
AUXIOA 57B78009 FRU List: CACHBAT 57B78100 FRU List: PTFSRCH Licensed Internal Code error Impending cache battery pack failure
ANYBRDG 57B78151 IOA detected recoverable device bus error FRU List: PTFSRCH Licensed internal code error
AUXIOA 57B78130
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: PRIMIOA
AUXIOA
AUXIOA 57B78156 FRU List: IOA detected recoverable device bus error A permanent failure occurred
BACKPLN 57B78140
PTFSRCH
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: PRIMIOA
AUXIOA
Servicer: Display the Service Action Log entry for this SRC.If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with
422
57B78300 57B83020
this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. FRU List: SVCDOCS 57B78300 FRU List: AUXIOA IOA hardware error or PCI bus error 57B79073 Multiple I/O adapters connected in a not valid configuration.
Refer to isolation procedure SIP3140. Isolation procedure SIP3140 can be located in your host servers service guide. 57B79076 Missing auxiliary IOA or remote IOA.
Refer to isolation procedure SIP3147. Isolation procedure SIP3147 can be located in your host servers service guide. FRU List:
ANYBRDG PRIMIOA PTFSRCH AUXIOA 57B78301 FRU List: PTFSRCH 57B7FF3D I/O adapter detected a recoverable error. Not valid condition in Licensed Internal Code
BACKPLN
If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: AUXIOA
Servicer: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
AUXIOA 57B79055 Write cache data is available for attached storage IOA.
Servicer: The I/O adapter error log is being filled faster than the errors are being reported to the system. Check other errors reported to the system and correct them. 57B83000 FRU List: STORIOA A permanent failure occurred
Servicer: No service action required. 57B79071 Link from IOA to auxiliary or remote IOA is operational
Servicer: No service action required. 57B79072 Link from IOA to auxiliary or remote IOA is non-operational
423
57B83100 57B84061
57B83100 FRU List: SIP3150 57B83140 System log entry only. Device bus interface error occurred 57B84020 Configuration error
Servicer: Number of connections exceed I/O adapter design limits. FRU List: SIP3143 57B84030 Configuration error
Servicer: Incorrect multipath connection. FRU List: SIP3144 57B84040 Configuration error
Servicer: The device is not supported in the current configuration. An I/O processor might be required. FRU List: SVCDOCS 57B83400 FRU List: SIP3150 FI02112 Unknown resource error
Servicer: Incomplete multipath connection between I/O adapter and enclosure. FRU List: SIP3144 57B84041 Incomplete multipath connection
Servicer: Incomplete multipath connection between device backplane and device. FRU List: SIP3146 57B84050 FRU List: SIP3148 57B84060 Format in progress Multipath redundancy level reduced Enclosure does not support required multipath function
STORIOA SASCABL 57B83401 FRU List: SASEXP DEVBPLN 57B834FF Device backplane problem
Servicer: A redundant disk unit connection has failed. FRU List: SIP3153 SASCABL SASEXP 57B84061 Multipath redundancy level increased
Servicer: No action required. This reference code is logged for information only. 57B83601 Format in progress
Servicer: System log entry only, no service action required 57B84010 Configuration error
Servicer: A redundant disk unit connection has been restored. No service action is required.
424
57B84070 57B88140
57B84070 System log entry only. BACKPLN
Servicer: No service action required. 57B84100 FRU List: SIP3152 SASCABL SASEXP DEVBPLN Device bus fabric error
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: CACHBAT 57B84101 FRU List: SIP3152 57B88009 57B84110 FRU List: SIP3145 57B84150 I/O adapter detected PCI bus error PTFSRCH Unsupported enclosure function detected FRU List: CACHBAT 57B88100 FRU List: Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: BACKPLN Licensed Internal Code error Impending cache battery pack failure Temporary device bus fabric error STORIOA
STORIOA
FI01105
STORIOA 57B84160 I/O adapter detected and recovered a PCI bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List: SIP3150 57B88140 IOA detected recoverable device bus error
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required. FRU List:
Servicer: If this event appears in a serviceable event view, work with the failing item list found there. If this event does not appear in a serviceable event view, no service action is required.
Chapter 6. 5xxx Reference Codes
425
57B88141 57B89000
FRU List: SIP3150 57B88141 IOA detected recoverable device error 57B88157 I/O adapter card error
Servicer: No action is required. This reference code is logged for information only. 57B88146 FRU List: FI01105 57B88150 A permanent failure occurred Disk device detected recoverable error
Servicer: Display the Service Action Log entry for this SRC.If the Failing Item indicates an I/O adapter, then replace the I/O adapter. If the Failing Item indicates SVCDOCS, then do NOT replace the I/O adapter. This is a recoverable error. Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. FRU List: SVCDOCS
Servicer Response: Note: Under a certain configuration, this SRC may not represent an error that requires a service action. Depending on the configuration of the system, the Storage IOA may have been altered and/or the Storage IOA Cache may have been disabled to allow attachment of OEM Storage that emulates a Load Source drive. If this is the case, this error will be posted each time the IOA is IPLed and it can be ignored. FRU List: STORIOA
Servicer: Ensure that the code necessary to support this I/O adapter is loaded. FRU List: SVCDOCS
Servicer: No service action required. 57B89000 FRU List: A permanent failure occurred FI01105 Device error
STORIOA
STORIOA
426
57B89001 57B89029
57B89001 FRU List: NEXTLVL 57B89002 FRU List: NEXTLVL 57B89008 FRU List: SIP3130 57B89010 FRU List: SIP3120 57B89011 FRU List: NEXTLVL 57B89020 FRU List: SIP3111 57B89022 FRU List: SIP3111 57B89023 FRU List: SIP3112 57B89024 FRU List: NEXTLVL
Chapter 6. 5xxx Reference Codes
57B89025
Incompatible device
Servicer: An incompatible device is at the physical location of the device which is causing the array to be exposed. FRU List: Device error SIP3110 FI02112 57B89026 Disk unit not found at required physical location
Servicer: A previously exposed disk unit in an array was not found at the required physical location. FRU List: Cache data associated with attached devices cannot be found NEXTLVL 57B89027 Array not functional due to parity out of synchronization
Servicer: Array is or would become exposed and parity data is out of synchronization FRU List: SIP3113 57B89028 Maximum number of functional arrays has been exceeded
Servicer: Reduce the number of arrays on this I/O adapter. Either move all the devices in an array to another I/O adapter that supports arrays, or stop an array on this I/O adapter. Two or more disk units missing from RAID-5 or RAID-6 array FRU List: SVCDOCS SIP3113 57B89029 Maximum number of functional array members has been exceeded
Servicer: Contact your next level of support. FRU List: Array member physical location conflicts with another array NEXTLVL SIP3113
427
57B89030 57B89074
57B89030 FRU List: SIP3110 FI02112 57B89031 Automatic rebuild initiated for array Array no longer protected due to missing or failed disk unit SIP3131 57B89051 FRU List: SIP3132 57B89052 Cache data exists for one or more modified devices Cache data exists for one or more missing or failed devices
Servicer: Either a previous rebuild was interrupted and was automatically restarted, or a hot spare disk unit was used to automatically rebuild the array. Look for other reference codes and take action on them. 57B89032 A disk unit in an array is missing or failed
Servicer: Contact your next level of support. FRU List: NEXTLVL 57B89054 FRU List: SIP3121 57B89070 System log entry only. IOA resources not available due to previous problems
Servicer: The array is still protected, but the disk unit should be replaced. FRU List: SIP3110 FI02112 57B89040 Resynchronization of array parity was initiated
Servicer: No service action required. 57B89071 Link from IOA to auxiliary or remote IOA is operational
Servicer: No action required. 57B89041 Background array parity check detected and corrected errors
Servicer: No service action required. 57B89072 Link from IOA to auxiliary or remote IOA is non-operational
Servicer: Call your next level of support to report the problem. FRU List: NEXTLVL 57B89042 Background parity check corrected errors on disk unit
Servicer: No service action required. 57B89073 FRU List: SIP3140 57B89074 Multiple I/O adapters connected in a not valid configuration Multiple I/O adapters connected in a not valid configuration
Servicer: Call your next level of support to report the problem. FRU List: NEXTLVL 57B89050 FRU List: Required cache data not found for one or more disk units
Servicer: Multiple I/O adapters not capable of similar functions or controlling the same set of devices. FRU List: SIP3141
428
57B89075 57B8FF3D
57B89075 FRU List: SIP3149 57B89076 FRU List: SIP3147 57B89081 FRU List: FI01105 Device error Missing auxiliary IOA or remote IOA Incomplete multipath connection between IOA and remote IOA FRU List: SVCDOCS 57B89092 FRU List: SIP3134 57B8C000 System log entry only, no service action required Disk unit requires initialization before use.
Servicer: No action is required. This reference code is logged for information only. 57B8C402 Device error Licensed Internal Code error
Servicer: Ask your next level of support for assistance.. FRU List: PTFSRCH 57B8FF3D FRU List: I/O adapter detected a recoverable error
STORIOA
Servicer: Use Hardware Service Manager to re-IPL the virtual I/O processor that is associated with this I/O adapter. Other resources attached to the virtual I/O processor may then need to be Varied On. If any reference codes are surfaced, use the new reference code to resolve the problem. If you cannot resolve the problem, contact your next level of support.
ANYBRDG
429
57553202 57559200
57553202 Tape unit configuration error 57559101 Fibre Channel interface error detected
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 57559020 Tape unit configuration error
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 57559102 Gateway device detected a SCSI interface error
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 57559100 Interface error detected by system or by tape unit
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 57559200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
430
57559201 57559302
FI00872 DEVTERM 57559201 Tape unit command timeout FRU List: FI00871 FI01112 PTFSRCH 57559211 Gateway device detected a bus protocol error 57559210 Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC
FI00872 FCCABLE DEVTERM FI00872 MH7TMED DEVTERM 57559202 Tape unit failed after Licensed Internal Code was loaded 57559300 FRU List: FI00871 57559301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 57559302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Chapter 6. 5xxx Reference Codes
431
57559303 57559802
57559303 Gateway device failure UH7CLN FI00871 57559355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 57559310 FRU List: PTFSRCH FI00871 57559320 FRU List: FI00130 FI00871 57559321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 57559500 Licensed Internal Code error.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 57559350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 57559800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 57559351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 57559801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 57559802 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Servicer Response: No action required. This reference code is logged for information only.
432
57559803 5755FFF6
57559803 System successfully recovered from temporary I/O error 57559902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only. 57559804 System successfully recovered from temporary I/O error
Servicer Response: No action required. 5755FFF6 Tape volume statistics logged (no action required)
Servicer Response: No action required. This reference code is logged for information only. 57559810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 57559899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 57559900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 57559901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only.
433
434
(6279, 6381, 6382, 6383, 6384, 6386, 6387, 63A0) Tape unit reference codes
A tape or tape library device failure occurred. Note: Use this table to handle reference codes that might be displayed during a type D IPL to install the operating system. If you are not performing a type D IPL of the operating system, consult any error logs found in the Serviceable Event View. If you cannot locate an error log in the Serviceable Event View that corresponds with the failure, run a verification test for the tape unit. 1. Verify that the device has power. 2. Check the device for any error indications. Refer to the device service information to resolve any error indications. 3. Clean the recording head in the tape device. 4. Attempt the failing operation again. Does the operation complete successfully? v Yes: You have corrected the problem. This ends the procedure. v No: Look at the 8 rightmost characters of the Data display for Function 11, which represent the reference code. Find the reference code in the following list.
62793202 Tape unit configuration error Servicer Response:
435
62799020 62799200
Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 62799020 Tape unit configuration error FCDEV FCCABLE 62799102 Gateway device detected a SCSI interface error 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 62799100 Interface error detected by system or by tape unit
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 62799200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 62799101 Fibre Channel interface error detected
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports.
436
62799201 62799303
62799201 Tape unit command timeout PTFSRCH 62799211 Gateway device detected a bus protocol error
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 62799202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE FI00872 DEVTERM 62799300 FRU List: FI00871 62799301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 62799210 FRU List: FI00871 FI01112 Illegal or unsupported tape unit response
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 62799302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871 62799303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Chapter 7. 6xxx Reference Codes
437
62799310 62799803
62799310 FRU List: PTFSRCH FI00871 Clean the tape unit and retry the operation. 62799320 FRU List: FI00130 FI00871 62799321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 62799500 Licensed Internal Code error. Licensed Internal Code for the tape unit is not correct 62799355 The data format is incorrect; the tape cannot be read
Servicer Response: The tape unit has detected that the data format on the tape media is not supported.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 62799350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 62799800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 62799351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 62799801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 62799802 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED UH7CLN FI00871
Servicer Response: No action required. This reference code is logged for information only. 62799803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
438
62799804 63819100
62799804 System successfully recovered from temporary I/O error 6279FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
Servicer Response: No action required. This reference code is logged for information only. 62799810 Problem analysis has determined a part should be replaced.
63813202
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 63819020 Tape unit configuration error
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 62799899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 62799900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63819100 Interface error detected by system or by tape unit
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 62799901 Tape performance statistics logged.
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: No action required. This reference code is logged for information only. 62799902 An IOP dump was initiated
439
63819101 63819202
63819101 Fibre Channel interface error detected FI00872 DEVTERM 63819201 Tape unit command timeout
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 63819102 Gateway device detected a SCSI interface error
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 63819202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63819200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
440
63819210 63819351
63819210 FRU List: FI00871 FI01112 PTFSRCH 63819310 63819211 Gateway device detected a bus protocol error FRU List: PTFSRCH FI00871 63819320 FRU List: FI00130 FI00871 ANYFC FCCABLE FI00872 DEVTERM 63819300 FRU List: FI00871 63819301 Tape device failure, redundancy lost Tape unit failure 63819321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct Illegal or unsupported tape unit response 63819303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63819350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63819302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63819351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Chapter 7. 6xxx Reference Codes
441
63819355 63819901
UH7CLN FI00871 63819355 The data format is incorrect; the tape cannot be read 63819803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63819804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63819500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 63819810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63819899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63819800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63819900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 63819801 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63819901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 63819802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only.
442
63819902 63829200
63819902 An IOP dump was initiated DEVTERM 63829101 Fibre Channel interface error detected
Servicer Response: No action required. 6381FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV
63823202
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 63829020 Tape unit configuration error
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63829100 Interface error detected by system or by tape unit
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63829200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
443
63829201 63829302
FI01112 FI00872 DEVTERM 63829201 Tape unit command timeout FRU List: FI00871 FI01112 PTFSRCH 63829211 Gateway device detected a bus protocol error 63829210 Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE
FI00872 FI00872 DEVTERM DEVTERM MH7TMED 63829300 63829202 Tape unit failed after Licensed Internal Code was loaded FRU List: FI00871 63829301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63829302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
444
63829303 63829802
63829303 Gateway device failure UH7CLN FI00871 63829355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 63829310 FRU List: PTFSRCH FI00871 63829320 FRU List: FI00130 FI00871 63829321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63829500 Licensed Internal Code error.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63829350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63829800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63829351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 63829801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63829802 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Servicer Response: No action required. This reference code is logged for information only.
445
63829803 63839100
63829803 System successfully recovered from temporary I/O error 63829902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only. 63829804 System successfully recovered from temporary I/O error
Servicer Response: No action required. 6382FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
63833202
Servicer Response: No action required. This reference code is logged for information only. 63829810 Problem analysis has determined a part should be replaced.
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63829899 Problem analysis completed, the problem has been corrected.
63839020
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63829900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63839100 Interface error detected by system or by tape unit
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63829901 Tape performance statistics logged.
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: No action required. This reference code is logged for information only.
446
63839101 63839202
DEVTERM 63839101 Fibre Channel interface error detected FI01112 FI00872 DEVTERM 63839201 Tape unit command timeout
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 63839102 Gateway device detected a SCSI interface error
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 63839202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63839200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
447
63839210 63839351
63839210 FRU List: FI00871 FI01112 PTFSRCH 63839310 63839211 Gateway device detected a bus protocol error FRU List: PTFSRCH FI00871 63839320 FRU List: FI00130 FI00871 ANYFC FCCABLE FI00872 DEVTERM 63839300 FRU List: FI00871 63839301 Tape device failure, redundancy lost Tape unit failure 63839321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct Illegal or unsupported tape unit response 63839303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63839350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63839302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63839351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
448
63839355 63839901
UH7CLN FI00871 63839355 The data format is incorrect; the tape cannot be read 63839803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63839804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63839500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 63839810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63839899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63839800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63839900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 63839801 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63839901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 63839802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only.
449
63839902 63849200
63839902 An IOP dump was initiated DEVTERM 63849101 Fibre Channel interface error detected
Servicer Response: No action required. 6383FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV
63843202
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 63849020 Tape unit configuration error
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63849100 Interface error detected by system or by tape unit
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63849200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
450
63849201 63849302
FI01112 FI00872 DEVTERM 63849201 Tape unit command timeout FRU List: FI00871 FI01112 PTFSRCH 63849211 Gateway device detected a bus protocol error 63849210 Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE
FI00872 FI00872 DEVTERM DEVTERM MH7TMED 63849300 63849202 Tape unit failed after Licensed Internal Code was loaded FRU List: FI00871 63849301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63849302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Chapter 7. 6xxx Reference Codes
451
63849303 63849802
63849303 Gateway device failure UH7CLN FI00871 63849355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 63849310 FRU List: PTFSRCH FI00871 63849320 FRU List: FI00130 FI00871 63849321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63849500 Licensed Internal Code error.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63849350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63849800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63849351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 63849801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63849802 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Servicer Response: No action required. This reference code is logged for information only.
452
63849803 63869100
63849803 System successfully recovered from temporary I/O error 63849902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only. 63849804 System successfully recovered from temporary I/O error
Servicer Response: No action required. 6384FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
63863202
Servicer Response: No action required. This reference code is logged for information only. 63849810 Problem analysis has determined a part should be replaced.
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63849899 Problem analysis completed, the problem has been corrected.
63869020
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63849900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63869100 Interface error detected by system or by tape unit
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63849901 Tape performance statistics logged.
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Chapter 7. 6xxx Reference Codes
Servicer Response: No action required. This reference code is logged for information only.
453
63869101 63869202
DEVTERM 63869101 Fibre Channel interface error detected FI01112 FI00872 DEVTERM 63869201 Tape unit command timeout
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 63869102 Gateway device detected a SCSI interface error
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 63869202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63869200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
454
63869210 63869351
63869210 FRU List: FI00871 FI01112 PTFSRCH 63869310 63869211 Gateway device detected a bus protocol error FRU List: PTFSRCH FI00871 63869320 FRU List: FI00130 FI00871 ANYFC FCCABLE FI00872 DEVTERM 63869300 FRU List: FI00871 63869301 Tape device failure, redundancy lost Tape unit failure 63869321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct Illegal or unsupported tape unit response 63869303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63869350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63869302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63869351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Chapter 7. 6xxx Reference Codes
455
63869355 63869901
UH7CLN FI00871 63869355 The data format is incorrect; the tape cannot be read 63869803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63869804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63869500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 63869810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63869899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63869800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63869900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 63869801 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63869901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 63869802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only.
456
63869902 63879200
63869902 An IOP dump was initiated DEVTERM 63879101 Fibre Channel interface error detected
Servicer Response: No action required. 6386FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV
63873202
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 63879020 Tape unit configuration error
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63879100 Interface error detected by system or by tape unit
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63879200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
457
63879201 63879302
FI01112 FI00872 DEVTERM 63879201 Tape unit command timeout FRU List: FI00871 FI01112 PTFSRCH 63879211 Gateway device detected a bus protocol error 63879210 Illegal or unsupported tape unit response
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC FCCABLE
FI00872 FI00872 DEVTERM DEVTERM MH7TMED 63879300 63879202 Tape unit failed after Licensed Internal Code was loaded FRU List: FI00871 63879301 Tape device failure, redundancy lost Tape unit failure
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63879302 Tape device failure or media error
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
458
63879303 63879802
63879303 Gateway device failure UH7CLN FI00871 63879355 The data format is incorrect; the tape cannot be read
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE 63879310 FRU List: PTFSRCH FI00871 63879320 FRU List: FI00130 FI00871 63879321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63879500 Licensed Internal Code error.
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63879350 Tape unit detected a read or write error on tape medium
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63879800 System successfully recovered from temporary I/O error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63879351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 63879801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63879802 System successfully recovered from temporary I/O error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
Servicer Response: No action required. This reference code is logged for information only.
459
63879803 63A09100
63879803 System successfully recovered from temporary I/O error 63879902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only. 63879804 System successfully recovered from temporary I/O error
Servicer Response: No action required. 6387FFF6 Tape volume statistics logged (no action required) Tape unit configuration error
63A03202
Servicer Response: No action required. This reference code is logged for information only. 63879810 Problem analysis has determined a part should be replaced.
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63879899 Problem analysis completed, the problem has been corrected.
63A09020
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63879900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH 63A09100 Interface error detected by system or by tape unit
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63879901 Tape performance statistics logged.
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: No action required. This reference code is logged for information only.
460
63A09101 63A09202
DEVTERM 63A09101 Fibre Channel interface error detected FI01112 FI00872 DEVTERM 63A09201 Tape unit command timeout
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors. 3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 63A09102 Gateway device detected a SCSI interface error
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 63A09202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 63A09200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871
461
63A09210 63A09351
63A09210 FRU List: FI00871 FI01112 PTFSRCH 63A09310 63A09211 Gateway device detected a bus protocol error FRU List: PTFSRCH FI00871 63A09320 FRU List: FI00130 FI00871 ANYFC FCCABLE FI00872 DEVTERM 63A09300 FRU List: FI00871 63A09301 Tape device failure, redundancy lost Tape unit failure 63A09321 Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct Illegal or unsupported tape unit response 63A09303 Gateway device failure
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 63A09350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 63A09302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 63A09351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED
462
63A09355 63A09901
UH7CLN FI00871 63A09355 The data format is incorrect; the tape cannot be read 63A09803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 63A09804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 63A09500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 63A09810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 63A09899 Problem analysis completed, the problem has been corrected.
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 63A09800 System successfully recovered from temporary I/O error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 63A09900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only. 63A09801 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 63A09901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 63A09802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only.
463
63A09902 6320C110
63A09902 An IOP dump was initiated 63A0FFF6 Tape volume statistics logged (no action required)
(632x, 6330, 6331, 6333, 6336, 6337) Optical storage unit reference codes
An optical storage unit failure occurred. Note: 1. If the system is available, use online diagnostic tests when possible. 2. Use the Hardware Service Manager (HSM) verify function (via DST or SST) and verify that the unit is operating correctly. 3. Search the problem log (WRKPRB) for a recent optical storage entry that may assist in analyzing the problem. The WRKPRB entry will provide a unit reference code that can be found in the following table. Perform the following: 1. If the system is available, attempt the failing operation again with an optical media that is known to be good. Does the operation complete successfully? v Yes: The original optical media may be defective, or the problem may be intermittent. Attempt the failing operation again with the original optical media to verify. This ends the procedure. v No: Look at the 8 rightmost characters of the Data display for word 1. These 8 characters are the reference code. Find the reference code in the following table.
6320C000 System log entry only, no service action required FRU List: FI00870 6320C100 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA FI01141 FI01140 6320C110 FRU List: FI00870 Undefined sense key returned by device CNVTCRD FI01106 STORIOA 6320C020 Device internal configuration error SCSI command timeout occurred SCSI bus command error occurred
Servicer Response: No action is required. This reference code is logged for information only. 6320C002 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA FI01141 FI01140 6320C010 FRU List: FI00870 SCSI selection or reselection timeout occurred
464
6320C210 6320CFF7
MEDIA FI01141 FI01140 6320C210 Unexpected device condition recovered MEDIA FI00870 6320C400 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA FI01141 FI01140 6320C402 Licensed Internal Code error Interface error detected by device
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6320C300 Media or device error occurred
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870 6320C301 Media or device error occurred
Servicer Response: Ask your next level of support for assistance. FRU List: FI00130 6320CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6320C302 Media or device error occurred
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6320CFF4 FRU List: FI00870 MEDIA Internal device error occurred
Servicer Response: The device encountered an out of spare sectors condition when writing to the media. The media can no longer be written to but is still readable. Clean the optical drive and the media contained in the drive. 6320C303 Media had an unknown format
Servicer Response: No action required. This reference code is logged for information only. 6320C333 Incompatible media was detected
6320CFF6
Servicer Response: No action is required. This reference code is logged for information only. 6320CFF7 Recovered device error.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List:
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only.
465
6320CFFE 6321C300
6320CFFE Recovered SCSI bus error 6321C020 FRU List: FI00870 6321C100 FRU List: FI00870 CNVTCRD FI01106 6320FF3D Recovered IOA error. STORIOA MEDIA FI01141 FI01140 6321C110 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA FI01141 FI01140 6321C210 Unexpected device condition recovered SCSI command timeout occurred SCSI bus command error occurred Device internal configuration error
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6320FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6320FF6D Recovered System bus error
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321C000 System log entry only, no service action required
Servicer Response: No action is required. This reference code is logged for information only. 6321C002 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA SCSI selection or reselection timeout occurred
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321C300 Media or device error occurred
FI01141 FI01140 6321C010 FRU List: FI00870 Undefined sense key returned by device
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870
466
6321C301 6321FF6D
6321C301 Media or device error occurred FI00130 6321CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6321C302 Media or device error occurred
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321CFF4 FRU List: FI00870 MEDIA 6321CFF6 Device successfully recovered from a temporary error. Internal device error occurred
Servicer Response: The device encountered an out of spare sectors condition when writing to the media. The media can no longer be written to but is still readable. Clean the optical drive and the media contained in the drive. 6321C303 Media had an unknown format
Servicer Response: No action required. This reference code is logged for information only. 6321C333 Incompatible media was detected
Servicer Response: No action is required. This reference code is logged for information only. 6321CFF7 Recovered device error.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870 6321C400 FRU List: FI00870 CNVTCRD FI01106 STORIOA MEDIA FI01141 Interface error detected by device
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321CFFE Recovered SCSI bus error
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: This reference code is logged for information only. 6321FF3D Recovered IOA error.
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only. 6321FF6D Recovered System bus error
Servicer Response: Ask your next level of support for assistance. FRU List:
Servicer Response: The device successfully recovered from a temporary error. No action is required. This reference code is logged for information only.
467
632BCFC1 632CC020
632BCFC1 Virtual media list access problem. A virtual optical device cannot access the file containing the list of volumes. 632BCFC6 Virtual optical volume is not valid. The file specified does not contain data that can be processed as a virtual optical volume.
Servicer Response: On this partition and the Network File System server, ensure the proper file is specified and proper authority is granted. FRU List: SVCDOCS 632BCFC2 VError reading virtual volume list. A non-recoverable error was detected while reading the list of volumes.
Servicer Response: On the Network File System server, ensure all the files specified in the list of optical volumes are correct. FRU List: SVCDOCS 632BCFC7 Virtual optical device detected error. A virtual optical device detected an error reported by the Network File System server that cannot be recovered.
Servicer Response: Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. FRU List: SVCDOCS 632BCFC3 Virtual media volume list is not valid. The data in the list of volumes is not valid.
Servicer Response: Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. FRU List: SVCDOCS 632BCFC8 Virtual optical device error. A virtual optical device encountered a non-recoverable error.
Servicer Response: On the Network File System server, ensure that the proper file is specified, that all files are entered correctly, that there are no blank lines, and that the character set used is valid. FRU List: SVCDOCS 632BCFC4 Virtual optical volume access problem. A virtual optical device cannot access the file containing the specified optical volume.
Servicer Response: Contact your next level of support for assistance. FRU List: NEXTLVL 632CC000 System log entry only, no service action required
Servicer Response: No action is required. This reference code is logged for information only. 632CC002 SCSI selection or reselection timeout occurred
Servicer Response: On the Network File System server, ensure the proper file is specified in the list of volumes, and that the proper authority is granted. FRU List: SVCDOCS 632BCFC5 Error reading virtual optical volume. A non-recoverable error was detected while reading a virtual optical volume.
Servicer Response: Refer to the hosting partition for problem analysis. 632CC010 Undefined sense key returned by device
Servicer Response: Refer to the hosting partition for problem analysis. 632CC020 Device internal configuration error
Servicer Response: Check for errors on the Network File System server and resolve them. Then retry the operation. If the failure reoccurs, contact your hardware service provider. FRU List: SVCDOCS
468
632CC100 632CFF3D
632CC100 SCSI bus command error occurred 632CC400 Interface error detected by device
Servicer Response: Refer to the hosting partition for problem analysis. 632CC110 SCSI command timeout occurred
Servicer Response: Refer to the hosting partition for problem analysis. 632CC402 Licensed Internal Code program error occurred
Servicer Response: Refer to the hosting partition for problem analysis. 632CC210 Unexpected device condition recovered. The device successfully recovered from a temporary error.
Servicer Response: Ask your next level of support for assistance. FRU List: PTFSRCH 632CCFF2 Recovered from device not ready - Start Unit issued. The device successfully recovered from a temporary error.
Servicer Response: No action is required. This reference code is logged for information only. 632CC300 Media or device error occurred
Servicer Response: Refer to the hosting partition for problem analysis. 632CC301 Media or device error occurred
Servicer Response: No action is required. This reference code is logged for information only. 632CCFF4 Internal device error occurred
Servicer Response: Refer to the hosting partition for problem analysis. 632CC302 Incompatible media was detected
Servicer Response: Refer to the hosting partition for problem analysis. 632CCFF6 The device successfully recovered from a temporary error
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. 4. 632CC303 Media had an unknown format
Servicer Response: No action is required. This reference code is logged for information only. 632CCFF7 Recovered device error. The device successfully recovered from a temporary error.
Servicer Response: No action is required. This reference code is logged for information only. 632CCFFE Recovered SCSI bus error. The device successfully recovered from a temporary error.
Servicer Response: No action required. This reference code is logged for information only. 632CC333 Incompatible media was detected
Servicer Response: No action is required. This reference code is logged for information only. 632CFF3D Recovered IOA error. The device successfully recovered from a temporary error.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. 4.
Servicer Response: No action is required. This reference code is logged for information only.
469
632CFF6D 6330C302
632CFF6D Recovered System bus error. The device successfully recovered from a temporary error. DEVTERM CDTRAY 6330C110 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6330C210 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6330C010 FRU List: FI00870 6330C020 FRU List: FI00870 6330C100 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 SCSI bus command error occurred Device internal configuration error Undefined sense key returned by device Unexpected device condition recovered SCSI command timeout occurred
Servicer Response: No action is required. This reference code is logged for information only. 6330C000 System log entry only, no service action required
Servicer Response: No action is required. This reference code is logged for information only. 6330C002 FRU List: FI00870 FI01106 FI01112 SCSI selection or reselection timeout occurred
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6330C300 Media or device error occurred
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870 6330C301 Media or device error occurred
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6330C302 Media or device error occurred
Servicer Response: While writing to the media, an out of spare sectors condition was encountered. The media can no longer be written to but is still readable.Clean the optical drive and the media contained in the drive.
470
6330C303 6331C002
6330C303 Media had an unknown format 6330CFF4 FRU List: FI00870 6330CFF6 6330C333 Incompatible media was detected Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870 6330C400 FRU List: FI00870 FI01106 FI01112 FI01140 6330FF3D FI01141 DEVTERM CDTRAY 6330C402 I/O processor internal program error occurred Recovered I/O processor error Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6330FF6D Recovered System bus error Interface error detected by device Device recovered from error after retries Internal device error occurred
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6330CFF7 Recovered device error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6330CFFE Recovered SCSI bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6330FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: Ask your next level of support for assistance. FRU List: FI00130 6330CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6331C000 System log entry only, no service action required
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
Servicer Response: No action is required. This reference code is logged for information only. 6331C002 FRU List: FI00870 FI01106
Chapter 7. 6xxx Reference Codes
471
6331C010 6331C333
FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6331C010 FRU List: FI00870 6331C020 FRU List: FI00870 6331C100 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 6331C303 DEVTERM CDTRAY 6331C110 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY SCSI command timeout occurred Media had an unknown format Servicer Response: No action required. This reference code is logged for information only. 6331C333 Incompatible media was detected 6331C302 Media or device error occurred SCSI bus command error occurred Device internal configuration error Undefined sense key returned by device 6331C300 Media or device error occurred Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870 6331C301 Media or device error occurred 6331C210 Unexpected device condition recovered
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive.
Servicer Response: While writing to the media, an out of spare sectors condition was encountered. The media can no longer be written to but is still readable.Clean the optical drive and the media contained in the drive.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870
472
6331C400 6333C020
6331C400 FRU List: FI00870 FI01106 FI01112 FI01140 FI01141 DEVTERM CDTRAY 6331C402 I/O processor internal program error occurred 6331FF3D Recovered I/O processor error Interface error detected by device 6331FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6331FF6D Recovered System bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333C000 System log entry only, no service action required
Servicer Response: Ask your next level of support for assistance. FRU List: FI00130 6331CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: No action is required. This reference code is logged for information only. 6333C002 FRU List: FI00870 FI01106 SCSI selection or reselection timeout occurred
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6331CFF4 FRU List: FI00870 6331CFF6 Device recovered from error after retries Internal device error occurred
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6331CFF7 Recovered device error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6331CFFE Recovered SCSI bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
473
6333C100 6333C402
6333C100 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6333C110 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6333C400 6333C210 Unexpected device condition recovered FRU List: FI00870 FI01106 FI01112 FI01140 FI01141 DEVTERM CDTRAY 6333C402 I/O processor internal program error occurred Interface error detected by device SCSI command timeout occurred 6333C333 Incompatible media was detected SCSI bus command error occurred 6333C301 Media or device error occurred
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6333C302 Media or device error occurred
Servicer Response: While writing to the media, an out of spare sectors condition was encountered. The media can no longer be written to but is still readable.Clean the optical drive and the media contained in the drive. 6333C303 Media had an unknown format
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333C300 Media or device error occurred
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870
474
6333CFF2 6336C100
FRU List: FI00130 6333CFF2 Recovered from device not ready - Start Unit issued 6336C000 System log entry only, no service action required
Servicer Response: No action is required. This reference code is logged for information only. 6336C002 FRU List: FI00870 FI01106 FI01112 SCSI selection or reselection timeout occurred
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333CFF4 FRU List: FI00870 6333CFF6 Device recovered from error after retries Internal device error occurred
MEDIA FI01140 FI01141 DEVTERM CDTRAY 6336C010 FRU List: FI00870 6336C020 FRU List: FI00870 6336C100 FRU List: FI00870 FI01106 SCSI bus command error occurred Device internal configuration error Undefined sense key returned by device
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333CFF7 Recovered device error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333CFFE Recovered SCSI bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: This reference code is logged for information only. 6333FF3D Recovered I/O processor error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6333FF6D Recovered System bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
475
6336C110 6336CFF2
6336C110 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6336C210 Unexpected device condition recovered 6336C333 Incompatible media was detected SCSI command timeout occurred 6336C303 Media had an unknown format
Servicer Response: No action required. This reference code is logged for information only.
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870 6336C400 FRU List: FI00870 FI01106 FI01112 FI01140 FI01141 DEVTERM CDTRAY Interface error detected by device
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6336C300 Media or device error occurred
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870
6336C402 6336C301 Media or device error occurred Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6336C302 Media or device error occurred
Servicer Response: Ask your next level of support for assistance. FRU List: FI00130 6336CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: While writing to the media, an out of spare sectors condition was encountered. The media can no longer be written to but is still readable.Clean the optical drive and the media contained in the drive.
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
476
6336CFF4 6337C110
6336CFF4 FRU List: FI00870 6336CFF6 Device recovered from error after retries Internal device error occurred FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY 6337C010 FRU List: FI00870 6337C020 6336CFFE Recovered SCSI bus error FRU List: FI00870 6337C100 FRU List: FI00870 FI01106 FI01112 MEDIA 6336FF3D Recovered I/O processor error FI01140 FI01141 DEVTERM CDTRAY 6337C110 FRU List: FI00870 FI01106 FI01112 MEDIA FI01140 FI01141 DEVTERM CDTRAY
Chapter 7. 6xxx Reference Codes
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6336CFF7 Recovered device error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6336FF09 Licensed Internal Code for optical device was not upgraded
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6336FF6D Recovered System bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6337C000 System log entry only, no service action required
Servicer Response: No action is required. This reference code is logged for information only. 6337C002 FRU List: FI00870 FI01106 SCSI selection or reselection timeout occurred
477
6337C210 6337CFFE
6337C210 Unexpected device condition recovered 6337C400 FRU List: FI00870 FI01106 FI01112 FI01140 FI01141 DEVTERM CDTRAY 6337C402 I/O processor internal program error occurred Interface error detected by device
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6337C300 Media or device error occurred
Servicer Response: Perform the following: 1. Clean the disk. 2. Attempt the failing operation again. 3. If this does not correct the problem, exchange the failing items. FRU List: MEDIA FI00870 6337C301 Media or device error occurred
Servicer Response: Ask your next level of support for assistance. FRU List: FI00130 6337CFF2 Recovered from device not ready - Start Unit issued
Servicer Response: Dust check encountered. Optical media and/or drives optical lens is dirty.Clean the optical drive and the media contained in the drive. 6337C302 Media or device error occurred
Servicer Response: While writing to the media, an out of spare sectors condition was encountered. The media can no longer be written to but is still readable.Clean the optical drive and the media contained in the drive. 6337C303 Media had an unknown format
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6337CFF4 FRU List: FI00870 6337CFF6 Device recovered from error after retries Internal device error occurred
Servicer Response: No action required. This reference code is logged for information only. 6337C333 Incompatible media was detected
Servicer Response: Perform the following: 1. Verify that the disk has a format that is given support. 2. If the format is given support, clean the disk and attempt the failing operation again. 3. If the operation fails again with the same reference code, ask your media source for a replacement disk. FRU List: MEDIA FI00870
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6337CFF7 Recovered device error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only. 6337CFFE Recovered SCSI bus error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
478
6337FF09 660x3109
6337FF09 Licensed Internal Code for optical device was not upgraded 6337FF6D Recovered System bus error
Servicer Response: This reference code is logged for information only. 6337FF3D Recovered I/O processor error
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
Servicer Response: The device successfully recovered from a temporary error.No action is required. This reference code is logged for information only.
Servicer Response: No action required. This reference code is logged for information only. 660x3100 Tape/optical or disk bus interface error occurred
Servicer Response: Perform DSKIP03. FRU List: DISKDRV STORIOA FI01106 FI01140
479
660x3110 660xFFF5
STORIOA FI01106 FI01140 660x3110 Disk bus interface error occurred 660x7003 Device format error
Servicer Response: If the disk has not been formatted by the system, initialize and format the disk. 660x7004 System log entry only. No service action required. Data compression failure
Servicer Response: Perform DSKIP03. FRU List: STORIOA DISKDRV FI01106 FI01140 660x3130 Device Licensed Internal Code
660x7050
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 660x7051 Compressed device and compression IOA are not compatible
Servicer Response: The device is not supported with the level of code currently on the system. Contact your next level of support. FRU List: SVCDOCS 660x3131 Device or IOA Licensed Internal Code
Servicer Response: Perform the procedure specified in Recovering From 6xxx7051 SRC in the Backup and Recovery Guide. FRU List: CMPRES1 660x7052 Data compression warning
Servicer Response: Perform the procedure specified in Recovering From 6xxx7052 SRC in the Backup and Recovery Guide. FRU List: SVCDOCS 660xFFF2 FRU List: DISKDRV Disk motor problem
Servicer Response: The device does not support a needed attribute and is running with degraded performance. Contact your next level of support. FRU List: SVCDOCS 660x7000 Disk sector read error
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 660x7001 Temporary disk data error
660xFFF3 FRU List: DISKDRV 660xFFF4 FRU List: DISKDRV STORIOA 660xFFF5
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV
480
660xFFF6 671x3020
660xFFF6 Disk device detected recoverable error 660xFFFE Temporary disk bus error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 660xFFF7 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01106 FI01140 671x102E Out of alternate sectors for disk storage
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 660xFFF8 Temporary disk data error
FRU List: DISKDRV 671x3002 FRU List: DISKDRV STORIOA Addressed device failed to respond to selection
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 660xFFF9 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 660xFFFA Temporary disk bus error
BACKPLN FI01106 FI01140 671x3010 FRU List: DISKDRV STORIOA FI01140 FI01141 671x3020 Storage subsystem configuration error Disk device returned wrong response to IOA
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01140 FI01141 BACKPLN 660xFFFB SCSI bus reset occurred
Servicer Response: If an MES is being installed, verify the configuration. FRU List: DISKDRV FI01106 STORIOA FI01140
Chapter 7. 6xxx Reference Codes
Servicer Response: No action required. This reference code is logged for information only.
481
671x3029 671x7051
671x3029 A device replacement has occurred 671x3131 Device or IOA Licensed Internal Code
Servicer Response: No action required. This reference code is logged for information only. 671x3100 Tape/optical or disk bus interface error occurred
Servicer Response: The device does not support a needed attribute and is running with degraded performance. Contact your next level of support. FRU List: SVCDOCS 671x7000 Disk sector read error
Servicer Response: Perform DSKIP03. FRU List: DISKDRV STORIOA FI01106 FI01140 671x3109 FRU List: DISKDRV STORIOA FI01106 FI01140 671x3110 Disk bus interface error occurred IOA timed out a disk command
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 671x7001 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 671x7003 Device format error
Servicer Response: If the disk has not been formatted by the system, initialize and format the disk. 671x7004 System log entry only. No service action required. Data compression failure
Servicer Response: Perform DSKIP03. FRU List: STORIOA DISKDRV FI01106 FI01140
671x7050
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 671x7051 Compressed device and compression IOA are not compatible
671x3130
Servicer Response: The device is not supported with the level of code currently on the system. Contact your next level of support. FRU List: SVCDOCS
Servicer Response: The customer should perform the procedure specified in Recovering From 6xxx7051 SRC in the Backup and Recovery Guide . FRU List: CMPRES1
482
671x7052 673x102E
671x7052 Data compression warning FRU List: DISKDRV 671xFFF9 Temporary disk data error
Servicer Response: The customer should perform the procedure specified in Recovering From 6xxx7052 SRC in the Backup and Recovery Guide. FRU List: SVCDOCS 671xFFF2 FRU List: DISKDRV 671xFFF3 FRU List: DISKDRV 671xFFF4 FRU List: DISKDRV STORIOA 671xFFF5 Disk sector read error Disk device problem Disk media format not valid Disk motor problem
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 671xFFFA Temporary disk bus error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01140 FI01141
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 671xFFF6 Disk device detected recoverable error
Servicer Response: No action required. This reference code is logged for information only. 671xFFFE Temporary disk bus error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 671xFFF7 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01106 FI01140 673x102E Out of alternate sectors for disk storage
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 671xFFF8 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code.
Chapter 7. 6xxx Reference Codes
483
673x3002 673x7001
673x3002 FRU List: DISKDRV STORIOA FI01106 BACKPLN FI01140 FI01106 FI01140 673x3010 FRU List: DISKDRV STORIOA FI01140 FI01141 673x3130 673x3020 Storage subsystem configuration error Device Licensed Internal Code Servicer Response: The device is not supported with the level of code currently on the system. Contact your next level of support. FRU List: SVCDOCS 673x3131 STORIOA FI01140 673x3029 A device replacement has occurred Device or IOA Licensed Internal Code Disk device returned wrong response to IOA 673x3110 Disk bus interface error occurred Addressed device failed to respond to selection 673x3109 FRU List: DISKDRV STORIOA IOA timed out a disk command
Servicer Response: Perform DSKIP03. FRU List: STORIOA DISKDRV FI01106 FI01140
Servicer Response: If an MES is being installed, verify the configuration. FRU List: DISKDRV FI01106
Servicer Response: The device does not support a needed attribute and is running with degraded performance. Contact your next level of support. FRU List: SVCDOCS 673x7000 Disk sector read error
Servicer Response: No action required. This reference code is logged for information only. 673x3100 Tape/optical or disk bus interface error occurred
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 673x7001 Temporary disk data error
Servicer Response: Perform DSKIP03. FRU List: DISKDRV STORIOA FI01106 FI01140
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List:
484
673x7003 673xFFFA
DISKDRV 673x7003 Device format error 673xFFF5 Disk sector read error
Servicer Response: If the disk has not been formatted by the system, initialize and format the disk. See Work with disk unit recovery. 673x7004 System log entry only. No service action required. Data compression failure
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 673xFFF6 Disk device detected recoverable error
673x7050
Servicer Response: Contact your next level of support. FRU List: SVCDOCS 673x7051 Compressed device and compression IOA are not compatible
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 673xFFF7 Temporary disk data error
Servicer Response: The customer should perform the procedure specified in Recovering From 6xxx7051 SRC in the Backup and Recovery Guide . FRU List: CMPRES1 673x7052 Data compression warning
Servicer Response: No action required. This reference code is logged for information only. FRU List: DISKDRV 673xFFF8 Temporary disk data error
Servicer Response: The customer should perform the procedure specified in Recovering From 6xxx7052 SRC in the Backup and Recovery Guide FRU List: SVCDOCS 673xFFF2 FRU List: DISKDRV 673xFFF3 FRU List: DISKDRV 673xFFF4 FRU List: DISKDRV STORIOA Disk device problem Disk media format not valid Disk motor problem
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 673xFFF9 Temporary disk data error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV 673xFFFA Temporary disk bus error
Servicer Response: A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01140
485
673xFFFB 6A590C20
FI01141 BACKPLN 673xFFFB SCSI bus reset occurred A disk unit service action is recommended only if the Service Action Log contains an entry for this reference code. FRU List: DISKDRV STORIOA FI01106 FI01140
Servicer Response: No action required. This reference code is logged for information only. 673xFFFE Temporary disk bus error
Servicer Response:
486
6A590C30 6A59FFFF
6A590C30 FRU List: FI00719 FI00718 6A590C90 6A590C40 FRU List: FI00719 FI00718 6A590CA1 6A590C43 FRU List: FI00719 FI00718 6A590C50 FRU List: FI00719 FI00718 6A590C53 FRU List: FI00719 FI00718 6A590C60 FRU List: FI00719 FI00718 6A590C63 FRU List: FI00719 FI00718 6A590C70 FRU List: FI00719 FI00718
Chapter 7. 6xxx Reference Codes
FRU List: FI00719 FI00718 6A590CC0 Communications adapter card test failed
FRU List: FI00719 FI00718 6A595007 Diagnostic wrap test completed; no errors detected Diagnostic wrap test completed; error was detected
487
488
Servicer Response: Before exchanging anyparts, verify that the following condition is not present: v The attached device type or model is only supported on an I/O adapter that is attached to an I/O processor. FRU List: UH7CNFG FI00871 72079020 Tape unit configuration error
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 2. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM 72079101 Fibre Channel interface error detected
Servicer Response: Before exchanging anyparts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support Tape and Dasd devices at the same time. v An unsupported device type or model is attached. FRU List: UH7CNFG FI00871 PTFSRCH
Servicer Response: If the attacheddevice is an external device, do the following before exchanging any parts: 1. Ensure that the Fibre Channel cable is correctly connected to the ports. 2. Clean the Fibre Channel connectors.
489
72079102 72079210
3. If there is a hub attached, verify that the hub is operational. 4. If there is a gateway device attached, refer to the gateway device service documentation for additional problem analysis procedures. 5. refer to the tape device service documentation for additonal problem analysis procedures. FRU List: FCIOA FCDEV FCCABLE 72079102 Gateway device detected a SCSI interface error 72079201 Tape unit command timeout
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the signal cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872 DEVTERM MH7TMED 72079202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FI00871 FCGATE FI00872 DEVTERM 72079200 Tape unit is not responding
Servicer Response: If the attached device is an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112 FI00872
Servicer Response: If the attached deviceis an external device, do the following before exchanging any parts: 1. Ensure that the device is powered on. 2. If an interposer is required, make sure that it is connected between the I/O processor and the SCSI cable. 3. Ensure that the SCSI cable is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 4. Ensure that a terminating plug is attached to the device end of the SCSI cable. FRU List: FI00871 FI01112
DEVTERM FI00872 DEVTERM 72079210 FRU List: FI00871 FI01112 Illegal or unsupported tape unit response
490
72079211 72079351
PTFSRCH 72079211 Gateway device detected a bus protocol error 72079310 FRU List: PTFSRCH FI00871 72079320 FRU List: FI00130 FI00871 72079321 FCCABLE FI00872 DEVTERM 72079300 FRU List: FI00871 72079301 Tape device failure, redundancy lost Tape unit failure Gateway device Licensed Internal Code error Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: Usethe gateway device service documentation to analyze the problem. FRU List: FCGATE FCIOA FI00871 ANYFC
Servicer Response: Use thegateway device service documenation to analyze the problem. FRU List: FCCODE 72079350 Tape unit detected a read or write error on tape medium
Servicer Response: The tape unitdetected a hardware failure that does not prevent the tape unit from completing the current operation. FRU List: FI00871 72079302 Tape device failure or media error
Servicer Response: A permanent read or write error occurred. Clean the tape unit and retry the operation. If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MH7TMED UH7CLN FI00871 72079351 Tape with excessive error rate was mounted in tape device.
Servicer Response: The tape unitdetected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnositic tests that can be run to isolate between hardware and media failures. FRU List: MH7TMED FI00871 72079303 Gateway device failure
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MH7TMED UH7CLN FI00871
Servicer Response: Use the gateway device servicedocumenation to analyze the problem. FRU List: FCGATE
491
72079355 72079902
72079355 The data format is incorrect; the tape cannot be read 72079804 System successfully recovered from temporary I/O error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation. If the operation continues to fail, use a different tape cartridge. FRU List: UH7USER MH7TMED UH7CLN FI00871 72079500 Licensed Internal Code error.
Servicer Response: No action required. This reference code is logged for information only. 72079810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information Only) 72079899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UH7FIXD 72079900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: If the system is operational, perform a dump of the I/O processor data. For more information, see Performing an IOP dump using hardware service manager. FRU List: PTFSRCH 72079800 System successfully recovered from temporary I/O error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape unit was not completed. The tape unit will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape unit. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UH7USER 72079901 Tape performance statistics logged.
Servicer Response: No action required. This reference code is logged for information only. 72079801 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 72079802 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 72079803 System successfully recovered from temporary I/O error
Servicer Response: No action required. This reference code is logged for information only. 72079902 An IOP dump was initiated
Servicer Response: No action required. This reference code is logged for information only.
492
7207FFF6 72080311
7207FFF6 Tape volume statistics logged (no action required)
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 7208030B Tape unit detected a read error on the tape medium
Servicer Response: Read (or write) errors may be caused by: v Poor or damaged tape v Dirty read/write heads v Damaged data cartridges v Using a data cartridge previously recorded in a format or density that is not correct v Using the wrong data cartridge (for example, one in a different format or density from another set of data cartridges) If the data on the tape was not written by i5/OS the format or the density may not be correct. Get or make a new copy of the data cartridge. If you are performing a write or a save operation, initialize the tape. See the note below.If you are performing a read or a restore operation, the tape may be worn or the device that
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED
493
72080316 72080396
46G2227 46G3934 42F7300 72080316 Tape unit detected a read error on the tape medium 46G2227 46G3934 42F7300 72080338 Tape unit detected a read error on the tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 46G3934 42F7300 7208031C The data format is incorrect; the tape cannot be read
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 46G3934 42F7300 7208033D Tape unit detected a read error on the tape medium
Servicer Response: The tape format is not known or not compatible. The data cartridge may not have been recorded using i5/OS.Get another copy of the data cartridge recorded in a format and density given support by i5/OS. FRU List: ML2TMED 46G2227
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 46G3934 42F7300
72080336
72080395
Servicer Response: The tape format is not known or not compatible. The data cartridge may not have been recorded using i5/OS.Get another copy of the data cartridge recorded in a format and density given support by i5/OS. FRU List: ML2TMED 46G2227 46G3934 42F7300 72080337 Tape unit detected a read error on the tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 72080396 Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED
494
72080397 72080418
72080397 Tape unit detected a write error on tape medium 46G2227 720803B3 Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 7208039D Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 720803B4 Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 7208039E Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 720803B5 Tape unit detected a read error on the tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 7208039F Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 72080417 Tape unit failure
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 720803AE Tape unit detected a read or write error on tape medium
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72080418 Tape unit failure
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 720803B0 Tape unit detected a read or write error on tape medium
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED
Chapter 8. 7xxx Reference Codes
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED
495
72080419 72080499
46G3934 42F7300 72080419 Tape unit failure ML2TMED 46G3934 42F7300 72080468 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72080458 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 7208046D Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 7208045A Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72080498 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72080467 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72080499 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List:
496
7208049A 720804A5
46G2227 ML2TMED 46G3934 42F7300 7208049A Tape unit failure 720804A2 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A3 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 7208049C Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A4 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A1 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A5 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934
497
720804A6 720804FC
42F7300 720804A6 Tape unit failure 46G3934 42F7300 720804AC Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A7 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804AD Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804A8 Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804FA Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804AB Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 720804FC Tape unit failure
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227
498
720804FD 72083110
ML2TMED 46G3934 42F7300 720804FD Tape unit failure 72083005 Blank tape or BOT encountered
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72083002 I/O processor addressed the tape unit; no response
Servicer Response: The tape drive has found a blank tape or BOT.When using a new data cartridge, the tape must first be initialized.This error can also occur when reading a tape if that tape was removed from the tape drive before writing was complete. Also see the Action for reference code 030B. FRU List: ML2TMED 46G2227 AJEDA00 72083010 Illegal or unsupported tape unit response
Servicer Response: The tape drive returned a response to the IOP that is illegal or is not given support. Call your next level of support FRU List: 46G2227 AJEDA00 72083100 Interface error detected by I/O processor or by tape unit
Servicer Response: The tape drive did not respond to commands from the IOP. Perform the following: 1. Ensure that the system interface cable is connected. 2. Ensure that power is on. If the above items are correct, call your next level of support FRU List: 46G2227 46G3934 FI00830 FI00141 46G2599 17G1500 42F7300 72083004 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: The IOP or the device detected a permanent error on the interface to the system. Call your next level of support FRU List: 46G2227 FI00141 FI00830 46G2599 42F7300 17G1500 46G3934 AJEDA00 72083110 Tape unit command timeout
Servicer Response: The tape drive does not respond to IOP commands after new Licensed Internal Code was transferred to the tape drive. Perform TU-PIP4. FRU List: 46G2227
Servicer Response: The tape drive did not complete a command sent by the IOP in the time allowed. Call your next level of support
Chapter 8. 7xxx Reference Codes
499
72084016 72089201
FRU List: 46G2227 FI00141 FI00830 46G2599 42F7300 17G1500 46G3934 AJEDA00 72084016 FRU List: AJEDA00 72084017 FRU List: AJEDA00 72089020 I/O processor detected a SCSI bus configuration error Licensed Internal Code for the tape unit is not correct Licensed Internal Code for the tape unit is not correct FRU List: 46G2227 FI00131 46G3934 FI00830 46G2599 17G1500 72089200 I/O processor addressed the tape unit; no response
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 46G2227 46G3934 FI00830 FI00131 46G2599 17G1500 42F7300 72089201 Tape unit command timeout
Servicer Response: Before exchanging any parts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support attachment of both tape and DASD devices at the same time. v A device type or model that is not given support. FRU List: UL2CNFG 46G2227 FI00130 72089100 Interface error detected by I/O processor or by tape unit
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 46G2227 46G3934 FI00830
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device.
500
72089202 72089350
FI00131 46G2599 17G1500 42F7300 72089202 Tape unit failed after Licensed Internal Code was loaded 42F7300 72089301 Tape device failure, redundancy lost
Servicer Response: The tape device detected a hardware failure that does not prevent the tape unit from completed the current operation.Refer to the Tape unit service information to determine the failing item. FRU List: 46G2227 ML2TMED 46G3934 42F7300 72089302 Tape device failure or media error
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 46G2227 46G3934 FI00830 FI00131 46G2599 17G1500 42F7300 72089210 FRU List: 46G2227 FI00130 FI00131 72089300 Tape unit failure Illegal or unsupported tape unit response
Servicer Response: The tape unit detected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnostic tests that can be run to isolate between hardware and media failures. FRU List: ML2TMED 46G2227 46G3934 42F7300 72089310 FRU List: 46G2227 FI00130 72089320 FRU List: FI00130 46G2227 72089350 Tape unit detected a read or write error on tape medium Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 46G2227 ML2TMED 46G3934
Servicer Response: A permanent read or write error occured. Clean the tape unit and retry the operation.If cleaning the tape unit does not correct the problem, exchange the tape media.
Chapter 8. 7xxx Reference Codes
501
72089351 72089900
FRU List: ML2TMED 46G2227 46G3934 42F7300 72089351 Tape with excessive error rate was mounted in tape device. 72089801 I/O processor successfully recovered from temporary error
Servicer Response: No action required. This reference code is logged for information only. 72089802 I/O processor successfully recovered from temporary error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: ML2TMED UL2CLN 46G2227 72089355 The data format is incorrect; the tape cannot be read
Servicer Response: No action required. This reference code is logged for information only. 72089803 I/O processor successfully recovered from temporary error
Servicer Response: No action required. This reference code is logged for information only. 72089810 Problem analysis has determined a part should be replaced.
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information only) 72089899 Problem analysis completed, the problem has been corrected.
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation.If the operation continues to fail, use a different tape cartridge. FRU List: UL2USR1 ML2TMED UL2CLN 46G2227 72089500 I/O processor Licensed Internal Code error
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: UL2FIXD 72089900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: If the system is operational, take a dump of the I/O processor data. For more information, see Service Functions located in your host systems service guide, or contact your next level of support for assistance FRU List: FI00130 72089800 I/O processor successfully recovered from temporary error
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape drive was not completed.The tape drive will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape drive. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UL2WAIT
Servicer Response: No action required. This reference code is logged for information only.
502
7208FF09 7208FFFF
7208FF09 Licensed Internal Code for tape unit was not upgraded FI00141 46G2599 17G1500 42F7300 7208FFF6 Tape volume statistics logged (no action required)
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape drive was not completed.The tape drive will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape drive. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: UL2WAIT 7208FF4D I/O processor successfully recovered from temporary error
Servicer Response: No action required. This reference code is logged for information only. 7208FFF8 Asynchronous device attached; synchronous device expected
Servicer Response: No action required. This reference code is logged for information only.When the system is available, display the operator messages, find message CPI946B, and press F14 to run online problem analysis to see if the error threshhold has been exceeded. FRU List: 46G2227 FI00141 FI00830 46G2599 46G3934 17G1500 42F7300 AJEDA00 7208FF5D I/O processor successfully recovered from temporary error
Servicer Response: The attached device is operational and working in the asynchronous mode of data transfer.The IBM tape unit uses the synchronous mode of data transfer; if the attached device is an IBM tape unit, exchange the tape unit. FRU List: 46G2227 7208FFFE Tape unit detected a read error on the tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227 46G3934 42F7300 7208FFFF Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 030B. FRU List: ML2TMED 46G2227
Servicer Response: No action required. This reference code is logged for information only.When the system is available, display the operator messages, find message CPI946B, and press F14 to run online problem analysis to see if the error threshhold has been exceeded. FRU List: 46G2227 46G3934 FI00830
503
504
Servicer Response: Refer to the 9427 8mm Tape Cartridge Library Service Guide.
Servicer Response: Read (or write) errors may be caused by: v Poor or damaged tape v Dirty read/write heads v Damaged data cartridges v Using a data cartridge previously recorded in a format or density that is not correct v Using the wrong data cartridge (for example, one in a different format or density from another set of data cartridges) Do the following: 1. Clean the tape unit and retry the operation. 2. If cleaning the tape unit does not correct the problem, exchange the tape media. 942704xx Tape unit failure
Servicer Response: Refer to the 9427 8mm Tape Cartridge Library Service Guide. 94274016 FRU List: AJEDA00 94274017 FRU List: AJEDA00 94279020 I/O processor detected a SCSI bus configuration error Licensed Internal Code for the tape unit is not correct Licensed Internal Code for the tape unit is not correct
Servicer Response:
Servicer Response: Before exchanging any parts, verify that the following conditions are not present: v Tape and DASD devices attached to an I/O Processor that does not support attachment of both tape and DASD devices at the same time.
505
94279100 94279300
v A device type or model that is not given support. FRU List: ULYCNFG 86G9251 FI00130 86G9254 94279100 Interface error detected by I/O processor or by tape unit 94279201 Tape unit command timeout
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 86G9251 FI00131 86G9254 EXTSCSI 17G9134 86G9255 86G9274 FI00130 94279202 Tape unit failed after Licensed Internal Code was loaded
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are no bent or damaged pins on the SCSI cable. 3. Ensure that a terminating plug is attached to the device. FRU List: 86G9251 FI00131 86G9254 EXTSCSI 86G9255 86G9274 17G9134 FI00130 94279200 I/O processor addressed the tape unit; no response
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 86G9251 86G9274 86G9254 94279210 FRU List: 86G9251 FI00130 FI00131 94279300 Tape unit failure Illegal or unsupported tape unit response
Servicer Response: Before exchanging any parts, do the following: 1. Ensure that the device is powered on. 2. Ensure that the SCSI cable between the device and the I/O Processor or I/O Adaptor is seated correctly, and that there are not bent or damaged pins on the SCSI cable. 3. Ensure that the terminating plug is attached to the device. FRU List: 86G9251 86G9274 86G9254 FI00131 EXTSCSI 17G9134 87G1531 86G9255
Servicer Response: The tape drive reported a hardware error to the IOP; the amber light on the tape drive may be blinking. Perform TU-PIP2. FRU List: 86G9251 LIBDEV MLYTMED 86G9274 86G9255
506
94279301 94279803
94279301 Tape device failure, redundancy lost 94279355 The data format is incorrect; the tape cannot be read
Servicer Response: The tape device detected a hardware failure that does not prevent the tape unit from completed the current operation.Refer to the Tape unit service information to determine the failing item. FRU List: 86G9251 LIBDEV MLYTMED 86G9274 86G9255 94279302 Tape device failure or media error
Servicer Response: The tape unit has detected that the data format on the tape media is not supported. Clean the tape unit and retry the operation.If the operation continues to fail, use a different tape cartridge. FRU List: ULYUSR1 MLYTMED ULYCLN 86G9251 94279500 I/O processor Licensed Internal Code error
Servicer Response: The tape unit detected a failure that may be caused by a hardware failure or a media error. Refer to the tape unit service information for possible information on diagnostic tests that can be run to isolate between hardware and media failures. FRU List: MLYTMED 86G9251 94279310 FRU List: 86G9251 FI00130 94279320 FRU List: FI00130 86G9251 94279350 Tape unit detected a read or write error on tape medium Tape device Licensed Internal Code failure Licensed Internal Code for the tape unit is not correct
Servicer Response: If the system is operational, perform a dump of the I/O processor data. FRU List: FI00130 94279600 Equipment Check Failure on Library Device.
Servicer Response: See library device service information to resolve the error. FRU List: LIBDEV 94279800 I/O processor successfully recovered from temporary error
Servicer Response: No action required. This reference code is logged for information only. 94279801 I/O processor successfully recovered from temporary error
Servicer Response: A permanent read or write error occured. Clean the tape unit and retry the operation.If cleaning the tape unit does not correct the problem, exchange the tape media. FRU List: MLYTMED 86G9251 94279351 Tape with excessive error rate was mounted in tape device.
Servicer Response: No action required. This reference code is logged for information only. 94279802 I/O processor successfully recovered from temporary error
Servicer Response: No action required. This reference code is logged for information only. 94279803 I/O processor successfully recovered from temporary error
Servicer Response: The tape unit detected that the mounted tape cartridge has a history of excessive read and write errors. It is recommended that you exchange the tape cartridge. FRU List: MLYTMED ULYCLN 86G9251
Servicer Response: No action required. This reference code is logged for information only.
507
94279810 9427FFFE
94279810 Problem analysis has determined a part should be replaced. press F14 to run online problem analysis to see if the error threshhold has been exceeded. FRU List: 86G9251 FI00141 EXTSCSI 17G9134 86G9253 86G9255 AJSLC01 9427FF5D I/O processor successfully recovered from temporary error
Servicer Response: This reference code is used for ending Online Problem Analysis with a list of failing items. (Information only) 94279899 Problem analysis completed, the problem has been corrected.
Servicer Response: This reference code is used for ending Online Problem Analysis when no problem was found or the problem was corrected. FRU List: ULYFIXD 94279900 Licensed Internal Code for tape unit was not upgraded
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape drive was not completed.The tape drive will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v Perform TU-PIP4 to reset the IOP and the tape drive. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: ULYWAIT 9427FF09 Licensed Internal Code for tape unit was not upgraded
Servicer Response: No action required. This reference code is logged for information only.When the system is available, display the operator messages, find message CPI946B, and press F14 to run online problem analysis to see if the error threshhold has been exceeded. FRU List: 86G9251 86G9253 EXTSCSI FI00141 17G9134 86G9255 9427FFF6 Tape volume statistics logged (no action required)
Servicer Response: No action required. This reference code is logged for information only. 9427FFF8 Asynchronous device attached; synchronous device expected
Servicer Response: The I/O processor loading of Licensed Internal Code (LIC) to the programmable tape drive was not completed.The tape drive will continue to operate with the previous LIC. You may do either of the following: v Wait for next IPL when the system will attempt to load the LIC for the tape drive again. v See the system service documentation to reset the IOP and the tape drive. When the IOP is reset, if the device has the wrong level of LIC, the IOP will attempt to load the new LIC. FRU List: ULYWAIT 9427FF4D I/O processor successfully recovered from temporary error
Servicer Response: The attached device is operational and working in the asynchronous mode of data tranfer. The IBM tape unit uses the synchronous mode of data transfer; if the attached device is an IBM tape unit, exchange the tape unit. FRU List: 86G9251 9427FFFE Tape unit detected a read error on the tape medium
Servicer Response: Perform the Action for reference code 03xx. FRU List: MLYTMED 86G9251 86G9253
Servicer Response: No action required. This reference code is logged for information only.When the system is available, display the operator messages, find message CPI946B, and
508
9427FFFF
9427FFFF Tape unit detected a write error on tape medium
Servicer Response: Perform the Action for reference code 03xx. FRU List: MLYTMED 86G9251
509
510
Servicer Response: The control panel displays this attention code after you request a partition dump (panel function 22). When you see this code, scroll to function 22 again on the panel and press Enter to perform the partition dump. Perform isolation procedure FSPSPD1. A1003042 Confirm platform dump (control panel function 42)
Servicer Response: The control panel displays this attention code after a restart IPL (panel function 03) is requested. When this SRC is displayed, scroll to function 03 again on the panel and press enter to perform the restart IPL. Perform isolation procedure FSPSPD1. A1008008 Confirm fast power-off (control panel function 08)
Servicer Response: The control panel displays this attention code after you request a platform dump (panel function 42). When you see this code, scroll to function 42 again on the panel and press Enter to perform the platform dump. Perform isolation procedure FSPSPD1. A1003043 Confirm service processor dump (control panel function 43)
Servicer Response: This attention code is displayed on the control panel after you request a fast power-off (panel function 08). When you see this code, scroll to function 08 again on the panel and press Enter to perform the fast power-off. Perform isolation procedure FSPSPD1. A1008009 Beginning emergency power off (EPO) countdown.
Servicer Response:
511
A100800A A2xx2320
Perform isolation procedure FSPSPD1. A100800A Proceeding with EPO. This SRC displays after the countdownhas completed successfully. A181D001 The hypervisor did not post an Xdown interrupt when a reset/reload occurred.
Servicer Response: Perform isolation procedure FSPSPD1. A1A3C100 Invalid operational mode for remote power on (wake onLAN)
Servicer Response: Perform isolation procedure FSPSPD1. A181D000 The hypervisor did not respond to a ROLE or FAILOVER message.
Servicer Response: Check the service processor settings for remote power on.
A2xx1150
A2xx1321
A2xx1225
A2xx1322
A2xx1230
A2xx2048
A2xx1260
A2xx2058
A2xx1265
A2xx2300
A2xx1281
A2xx2310
A2xx1310
A2xx2320
512
A2xx2425 A2xx5123
A2xx2425 A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A2xx3135 A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required.
A2xx2426
A2xx3140
A2xx2475
A2xx3141
A2xx2485
A2xx3142
A2xx3081
A2xx3143
A2xx3084
A2xx3144
A2xx3088
A2xx3200
A2xx308C
A2xx4158
A2xx3110
A2xx5106
A2xx3113
A2xx5109
A2xx3114
A2xx5114
A2xx3120
A2xx5115
A2xx3123
A2xx5117
A2xx3125
A2xx5121
A2xx3128
A2xx5122
A2xx3130
A2xx5123
513
A2xx5135 A2xx8117
A2xx5135 A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during a partition Firmware Assisted Dump. No service action required. A problem occurred during a partition Firmware Assisted Dump. No service action required. A problem occurred during a partition Firmware Assisted Dump. No service action required. A problem occurred during a partition Firmware Assisted Dump. No service action required. A problem occurred during a partition Firmware Assisted Dump. No service action required. System log entry only, no service action required. A2xx8113 A2xx543D A problem occurred during a partition Firmware Assisted Dump. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A2xx6025 A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required.
A2xx5137
A2xx6027
A2xx5145
A2xx6110
A2xx5148
A2xx690A
A2xx5149
A2xx7200
A2xx514A
A2xx8080
A2xx8081 A2xx542A
A2xx8105
A2xx542B
A2xx8107
A2xx543A
A2xx8109
A2xx543B
A2xx8111
A2xx8112 A2xx543C
A2xx8114
A2xx6006
A2xx8115
A2xx6012
A2xx8117
A2xx6015
514
A2xx8121 A2xxF00A
A2xx8121 A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A2xxC1F0 A2xx8129 A problem occurred during the IPL of a partition. No service action required. A2xxD150 A2xx813A A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required. Platform LIC detected an error. No service action required. Platform LIC detected an error. No service action required. No active system processors. No service action required. A problem occurred after a partition ended abnormally. No service action required. A2xxE0AA A2xxA101 A problem occurred after a partition ended abnormally. No service action required. System log entry only, no service action required. A problem occurred after a partition ended abnormally. No service action required. A problem occurred during a power off a partition. No service action required. A problem occurred after a partition ended abnormally. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. A system request to power off a partition failed. No service action required. A system request to power off a partition failed. No service action required. A problem occurred during the IPL of a partition. No service action required. A problem occurred during a power off a partition. No service action required. A problem occurred during the IPL of a partition. No service action required. System log entry only, no service action required. System log entry only, no service action required.
A2xx8123
A2xxB07B
A2xx8125
A2xxB215
A2xx8127
A2xx8140
A2xx8141
A2xxF001
A2xx8142
A2xxF003
A2xx8143
A2xxF004
A2xx8144
A2xxF005
A2xx8145
A2xxF006
A2xx8150
A2xxF007
A2xx8151
A2xxF008
A2xx8152
A2xxF009
A2xxA100
A2xxF00A
515
A2xxF00B A6xx0200
A2xxF00B System log entry only, no service action required. A2xxF00C System log entry only, no service action required.
Servicer Response: This reference codeis for information only. It is shown in the Product activity log as a sideeffect of a condition that was detected by LIC. Normally, no actionshould be taken as a result of information reference codes. However, to isolatethe root cause, use these suggestions: 1. Examine the date and time of the informational reference code. 2. Determine if any other reference codes have been logged at or before the same date and time. 3. Begin the service approach based on these other logged errors. A6xx0102 A machine check occurred during IPL
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0107 Main storage dump must be copied for service.
Servicer Response: Theserver detected an unrecoverable machine check condition. Collect allthe words of the SRC and the main store dump and send to your system manufacturerfor analysis. A6xx0109 An unrecoverable memory error occurred.
Servicer Response: Words 2 to 9of this SRC contain additional diagnostic information. Record SRC words 1through 9 before attempting to IPL again and report the problem to your SoftwareService Provider. A6xx0103 Main storage dump must be copied for service.
Servicer Response: Re-IPL the partition that terminated. Then, look for and correct errors with SRCs of the form B1xxxxxx in the Serviceable Event View that indicate the replacement of memory in the failing item list. If there are no B1xxxxxx SRCs in the Serviceable Event View that indicate a memory problem, perform a slow boot in order to run diagnostics on the memory. Then, look for and correct errors with SRCs of the form B1xxxxxx in the Serviceable Event View. A6xx0200 System firmware has experienced a low storage condition. No immediate action is necessary.
Servicer Response: Perform LICIP01. A6xx0104 Terminate Immediate reference code is bad
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0105 More than one request to terminate the system was issued
Servicer Response: Continue running the system normally. At the earliest convenient time work with your service provider to perform a platform dump and reIPL the system. FRU List: SVCDOCS
516
A6xx0202 A6xx0305
A6xx0202 Unrecoverable read error FI00500 FI00302 FI00301 AJDG301 A6xx0277 A compression disk unit cannot complete an operation.
Servicer Response: Restore the Licensed Internal Code using Licensed Internal Code Install and Restore in Service Functions located in your host systems service guide, or contact your next level of support for assistance. A6xx0210 The system ASP has run out of disk storage
Servicer Response: The outof storage condition in the system ASP can be caused by an allocation failurein some other system software. This could be a looping condition that continuesto allocate storage. Contact your service representative for assistance withthe Main Storage Dump. A6xx0244 Contact was lost with the device indicated
Servicer Response: Note: Do not power off the system when performing this procedure. Look at the 4 leftmost characters of the Data display for word 7. These four characters indicate the type of problem that exists and the recovery action to perform. If these characters are 8402 or 2002, thecompression disk unit is temporarily full of data. The command to the compressiondisk is being held. When the storage subsystem controller has created sufficientspace on the compression disk unit to contain the data, the command whichis being held will be released and the system will resume normal processing. If the system does not resume normal processing w ithin 20 minutes, contactyour next level of support. If these characters are 8400 or 2000,the compression disk unit is full of data. The command to the compressiondisk is being held. The customer should perform the recovery actions specified in Disk Unit Full Considerations in the Backup and Recovery Guide, SC41-5304.
Servicer Response: Do notpower off the system. Perform LICIP13. FRU List: FI00580 FI00500 FI00302 FI00301 AJDG301 A6xx0255 Contact was lost with the device indicated
A6xx0302
Servicer Response: Do notpower off the system. Perform LICIP13. FRU List: FI00580 FI00500 FI00302 FI00301 AJDG301 A6xx0266 Contact was lost with the device indicated
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0304 FRU List: AJDG301 A6xx0305 Exception while storage management lock is held. Component specific exception handler return code notvalid. Perform LICIP08.
Servicer Response: Do notpower off the system. Perform LICIP13. FRU List: FI00580
517
A6xx0307 A6xx0401
A6xx0307 LIC exception code detected a problem AJDG301 A6xx0328 LIC exception code detected a problem
Servicer Response: Component Specific Exception Handler recursion is detected in an OS/400 process. Perform LICIP08. FRU List: AJDG301 A6xx0308 LIC exception code detected a problem
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0329 LIC exception code detected a problem
Servicer Response: Component SpecificException Handler recursion is detected in an OS/400 process. Perform LICIP08. FRU List: AJDG301 A6xx0317 Traceback for code not found
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0333 A branch to a bad address was attempted
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0323 LIC exception code detected a problem
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0334 Exception Handler could not be removed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0324 LIC exception code detected a problem
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0335 Code resumed to not valid address following exception
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0325 LIC exception code detected a problem
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0336 LIC exception code detected a problem.
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0326 LIC exception code detected a problem
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0401 A machine check occurred during IPL
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0327 LIC exception code detected a problem
518
A6xx0402 A6xx0417
A6xx0402 A machine check occurred during authority initialization A6xx0410 Unhandled exception in journal clean up
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0403 Unhandled exception during IPL or install
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0411 Unhandled exception in commit recovery
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0405 Unhandled exception in authority recovery
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0412 Unhandled exception in commit initialization
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0406 Unhandled exception in data base recovery
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0413 Rebuild of recovery object index failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0407 Unhandled exception in data base initialization
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0414 Install of operating system failed on read from media
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0408 Unhandled exception in journal recovery
Servicer Response: Perform LICIP08. FRU List: FI00300 A6xx0415 Create user profile failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0417 Initiating the initial process failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0409 Unhandled exception in journal synchronization
519
A6xx0418 A6xx0650
A6xx0418 FRU List: AJDG301 A6xx0419 FRU List: AJDG301 A6xx0420 FRU List: AJDG301 A6xx0421 Bad return code creating a queue or message The information loaded from the install media is notvalid. Perform LICIP08. The information loaded from the install media is notvalid. Perform LICIP08. The information loaded from the install media is notvalid. Perform LICIP08. A6xx0443 Programmed IPL command failure
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0446 Error during machine termination
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0447 Failure to reach MI boundary
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0449 Exception in MI boundary manager
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0422 The Load/Dump command failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0506 Attempt to destroy a task with critical flag on
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0439 Opening the IPCF connection failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0607 Maximum stack size exceeded in process or task
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0440 Termination code is not valid
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0620 Event management index is not usable
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0441 Power off system command failed
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx0650 Resource management segment could not be created orextended. A main store dump was initiated.
520
A6xx0801 A6xx1204
Words 2 to 9 of this SRCcontain additional diagnostic information. Record SRC words 1 through 9. Perform a system IPL and collect the Product activity log and main store dump and provide them along with the recorded SRC information to IBM Service Support. The problem may also be that there is not enough auxiliary storage. FRU List: AJDG301 A6xx0801 Invalid LID directory detected A6xx0903 The LinkLoader was not able to allocate a segment
Servicer Response: Perform the D mode IPL again. If the problem persists, there might be a memory problem. Contact your next level of support. A6xx0904 The LinkLoader was not able to load a critical LID
Servicer Response: Perform the D mode IPL again. If the problem persists, contact your next level of support. A6xx1001 Enqueuing a task to the TDQ which is already enqueuedon TDQ. Perform LICIP08.
Servicer Response: During system IPL,the LIDMgr detected an I/O failure or media failure while trying to read the LID directory. Perform LICIP08. FRU List: FI00070 FI00300 AJDG301 A6xx0802 LID directory unusable
FRU List: AJDG301 A6xx1103 MISR not readable; must be readable for Normal Modeinstall
Servicer Response: MISR is not readable. Perform a manual install to reinitializethe system. A6xx1104 Failure reading media or not install media
Servicer Response: During system IPL, the LIDMgrdetected that the LID directory and associated load source is not usable. Reinstall the Licensed Internal Code by using Utilities to install and restore Licensed Internal Code . For more information, contact IBM Service Support. FRU List: AJDG301 A6xx0901 The LinkLoader has found its bad flag ON
Servicer Response: Determinethat correct install media is loaded. If correct install media is installed,media could be corrupt. Obtain another copy of the install media and reattemptthe install. If the install still fails, contact your service representative. A6xx1201 Critical database segment could not be created
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx1204 Error in constraint enforcement
Servicer Response: This referencecode is usually the result of a system termination while the LinkLoader is performing its work. Reinstall the Licensed Internal Code by using Utilities to install and restore Licensed Internal Code. A6xx0902 Unable to perform programmed IPL
Servicer Response: The LinkLoader wasnot successful in performing a programmed IPL. Perform a system IPL. If the problem persists, examine the main storage dump and determine the reason for the failure of the programmed IPL.
521
A6xx1210 A6xx4404
A6xx1210 Object not found in the in-use table A6xx3000 Logical partition service function Main Storage Dump.
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx1215 Error in critical code sequence
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx1219 A back leveled driver has been detected
Servicer Response: Copy the current main storage dump to media. For more information on how to copy a Main Storage Dump, refer to Service Functions located in your host systems service guide, (see Copying a Main Storage Dump under Working with Storage Dumps), or contact your next level of support for assistance. FRU List: AJDG301 A6xx4401 Missing DASD units.
Servicer Response: Perform LICIP08. FRU List: AJDG301 A6xx1604 Not able to create APPN task
Servicer Response: Copy the current main storage dump to media. For more information on how to perform a Main Storage Dump, refer to Service Functions located in your host systems service guide, (see Copying a Main Storage Dump under Working with Storage Dumps), or contact your next level of support for assistance. A6xx4402 Missing DASD units.
Servicer Response: An error occurred duringtask creation which requires a power off of the system. Perform LICIP08. FRU List: AJDG301 A6xx1724 An attempt to create a segment failed
Servicer Response: The createcould fail for two reasons: v A code problem. Perform LICIP08. v No free auxiliary storage on the system. Add additional DASD if the create failed because no auxiliary storage was available. FRU List: AJDG301 A6xx1730 An IPL is needed to restore system performance
Servicer Response: Copy the current main storage dump to media. Then exit the Main Storage Dump Manager. For more information on how to perform a Main Storage Dump, refer to Service Functions located in your host systems service guide, (see Copying a Main Storage Dump under Working with Storage Dumps), or contact your next level of support for assistance. A6xx4403 Storage Management failed to reach full paging.
Servicer Response: Copy the current main storage dump to media. For more information on how to perform a Main Storage Dump, refer to Service Functions located in your host systems service guide, (see Copying a Main Storage Dump under Working with Storage Dumps), or contact your next level of support for assistance. A6xx4404 Auto copy failed or not attempted.
Servicer Response: LicensedInternal Code has detected a condition that is impacting system performance. System operation can continue, but system performance may be noticeably reduced until the next IPL. Look at the Product Activity Log entry, and find the value at offset x000180. If the value equals x00000122, the error was caused by too much processor memory being installed. For more information, contact IBM Service Support. FRU List: GG4PL01
Servicer Response: Copy the current main storage dump. If copying to system ASP, existing copies may need to be deleted or renamed. Then exit the Main Storage Dump Manager. For more information on how to perform a Main Storage Dump, refer to Service Functions located in your host systems service guide, (see Copying a Main Storage Dump under Working with Storage Dumps), or contact your next level of support for assistance.
522
A6xx4405 A6xx4714
A6xx4405 System ASP threshold exceeded after auto copy done. A6xx4701 Processor On Demand error detected.
Servicer Response: Delete other system ASP copies or exit the Main Storage Dump Manager and then from DST copy the Auto Copy to media and then delete the Auto Copy in system ASP. A6xx4420 MSD Manager not configured to save dump information
Servicer Response: Processor OnDemand Data Block contains data that does not match the expected data. Contact your service provider. FRU List: AJDG301 A6xx4703 Processor On Demand error detected.
Servicer Response: The platform produced dump data, but the Main Storage Dump (MSD) Manager was not configured to automatically copy the dump to an Auxiliary Storage Pool (ASP). The dump will be lost if the system power is lost. Use MSD Manager to manually copy the current platform dump to media or an ASP. A6xx4421 Insufficient space in the ASP to store a platform dump
Servicer Response: Processor OnDemand Serialization has failed during IPL. Contact your service provider. FRU List: AJDG301 A6xx4710 Processor On Demand error detected.
Servicer Response: The platform produced dump data, and the Main Storage Dump (MSD) Manager was configured to automatically copy the dump to an Auxiliary Storage Pool (ASP), but there was not sufficient free space available in the ASP. The dump will be lost if the system power is lost. Manually copy the current platform dump from the platform by performing one of the following: v Make room in the designated ASP and then use the MSD Manager to copy the current platform dump to ASP. v Use the MSD Manager to delete other dump copies, then copy the current platform dump to ASP. v Use the MSD Manager to copy the current platform dump to a different ASP. v Use the MSD Manager to copy the current platform dump to media. A6xx4422 A platform dump is saved in MSD Manager
Servicer Response: SPCN communicationfailure during Processor On Demand. Look in the Product Activity Log for other SPCN errors and perform the actions indicated for those errors. FRU List: SPNLCRD A6xx4712 Processor On Demand error detected.
Servicer Response: Correct anyProcessor Capacity card or SPCN failures. FRU List: CTLPNCD A6xx4713 Incorrect Processor Capacity Card installed.
Servicer Response: TheProcessor Capacity Card is the failing item since it has been swapped in from a different system. Put the Processor Capacity Card back in the system it came from, and reinstall this systems original Processor Capacity Card. FRU List: CTLPNCD A6xx4714 The CUoD data is not present. A problem may exist.
Servicer Response: The platformproduced dump data. The dump data was copied to the Main Storage Dump (MSD) Manager. FRU List: PLDUMP A6xx4700 Processor On Demand error detected.
Servicer Response: Processor onDemand Data Block key is not valid. Replace the Processor Capacity card. FRU List: CTLPNCD
Servicer Response: The Processor Capacity Card was changed and there may be a problem. If the system did have any activated standby processors before the Processor Capacity Card was
523
A6xx4715 A6xx5003
replaced, then new processor on demand activation codes must be obtained to restore the previous activations. Contact your service provider. A6xx4715 Processor On Demand error detected. A6xx4747 1 hour left in POD 14 day Trial Activation Period. A6xx4745 Processor Capacity card replaced on activated POD system.
Servicer Response: Contact IBM Support to order a replacement Processor On Demand activationcode.
Servicer Response: Correct anyProcessor Capacity card or SPCN failures. FRU List: CTLPNCD A6xx4730 Processor On Demand error detected.
Servicer Response: If a new activation code was purchased, it should be entered now. Otherwise, the system will revert back to its previous activation state at the end of the Trial Activation Period. A6xx5001 DST received no response from a work station controller
Servicer Response: Processor OnDemand standby processors are in use. Contact your service provider. FRU List: AJDG301 A6xx4731 Processor On Demand error detected.
Servicer Response: The workstation I/O processor for the system or partition console did not respond. Perform RTRIP01 to determine which Isolation procedure to perform. FRU List: FI00380 AJDG301 Processor On Demand error detected. A6xx5002 DST problem attempting to use the system console.
Servicer Response: The ProcessorOn Demand Trial Activation period is not valid. Contact your next level of support. FRU List: AJDG301 A6xx4733
Servicer Response: Contact yourservice provider. FRU List: AJDG301 A6xx4740 Processor On Demand error detected.
Servicer Response: A code problem occurred during an attempt to use the system console. Perform LICIP03. FRU List: AJDG301 FI00380 A6xx5003 Service program failed
Servicer Response: The ProcessorOn Demand Activation code just entered is not valid. Contact your next level of support. FRU List: AJDG301 A6xx4741 Processor On Demand error detected.
Servicer Response: The ASCII system console failedto respond. FRU List: FI00320 FI00602 UG4USR1 AJDG301 FI00380
Servicer Response: An invalid ProcessorOn Demand Activation code has been entered more than 5 consecutive times. Contact your service provider. FRU List: AJDG301
524
A6xx5004 A6xx5092
A6xx5004 DST console failed to respond A6xx5010 FRU List: AJDG301 A6xx5082 DST lost contact with the console IPL service function ended abnormally.Perform LICIP04.
Servicer Response: The system consolefailed to respond. Perform RTRIP02 to determine which isolation procedure to perform. FRU List: FI00320 FI00602 UG4USR1 AJDG301 FI00380 A6xx5005 Service program failed
Servicer Response: A service programlost contact with the system console. Perform RTRIP03 to determine which isolation procedure to perform. FRU List: AJDG301 UG4USR1 A6xx5083 IPL service function ended abnormally
Servicer Response: The workstation adapter systemconsole failed to respond. Perform WSAIP01. FRU List: FI00320 FI00602 UG4USR1 AJDG301 FI00380 A6xx5007 Service program failed
Servicer Response: A service programlost contact with the system console. Perform TWSIP01. FRU List: AJDG301 UG4USR1 A6xx5090 System startup failed in unattended IPL mode
Servicer Response: Performthe following: v If reference code A6005090 is displayed on the control panel for more than 10 minutes, perform LICIP11. v For reference code B6005090, perform LICIP11. FRU List: FI00580 FI00500 FI00301 FI00021 FI00065 AJDG301 DST console failed to respond. Perform OPCIP03. A6xx5092 System is in DASD migration mode
Servicer Response: The workstation adapter consolefailed to respond. Perform RTRIP07 to determinewhich isolation procedure to perform. FRU List: FI00320 FI00602 UG4USR1 AJDG301 FI00380 A6xx5008 FRU List: FI00719
Servicer Response: Install LicensedInternal Code and Upgrade Load Source was specified but the key is not in the manual position. Change the key position to manual and perform a system IPL.
525
A6xx5094 A6xx5128
A6xx5094 IASP detected a failure during the vary on operation A6xx5123 System LIC program exception occurred
Servicer Response: Perform LICIP12. FRU List: SVCDOCS A6xx50FF DST unrecoverable program error
Servicer Response: System LICdetected an interface problem with the IOP or an IOP programming problem for which an IOP and main storage dump may have been initiated.Perform LICIP01. FRU List: FI00130 AJDG301 FI00131 A6xx5126 Addressed device failed to respond to selection
Servicer Response: Perform LICIP03. FRU List: AJDG301 FI00380 A6xx5120 System LIC detected a program exception
FRU List: DISKDRV STORIOA DISKTRY FI01106 FI01140 FI01141 DEVTERM BACKPLN A6xx5127 IOP timed out a disk command
Servicer Response: System LICdetected a programming problem. If performance or other system degradation is occurring, the system may be operating with reduced resources. Check the Product activity log for related entries. If this reference code is logged with a Class of Informational, then no action is required. Otherwise, perform LICIP01. FRU List: AJDG301 FI00130 A6xx5121 System LIC program exception occurred
Servicer Response: System LICdetected a programming problem for which a main storage dump may have been initiated. A problem log entry may be generated for this ref code. Perform LICIP01. FRU List: AJDG301 A6xx5122 System LIC program exception occurred
FRU List: DISKDRV STORIOA FI01106 DISKTRY FI01140 FI01141 DEVTERM BACKPLN A6xx5128 FRU List: FI01112 FI01107 I/O processor failure
Servicer Response: System LICdetected an IOP programming problem for which an IOP dump may have been initiated. Perform LICIP01. FRU List: FI00130 AJDG301 FI00131
526
A6xx512D A6xx5310
A6xx512D An IOP dump was initiated FI00130 AJDG301 A6xx5275 The system issued a reset/reload to the IOP.
Servicer Response: Copy the IOP dump entryand any related entries from the Product Activity Log to suitable media, and give to an IBM service representative. A6xx512E System LIC program exception occurred
Servicer Response: The systemwas in a D IPL mode when the problem was detected. A main storage dump was not taken. Perform LICIP01. FRU List: AJDG301 FI00130 A6xx5206 System LIC detected a missing IOP LIC code load
Servicer Response: SystemLicensed Internal Code detected that an IOP Reset/Reload has occurred, and that the IOP successfully recovered. Users who were signed on to a Workstation device under the IOP will need to sign back on. Any LAN/WAN communications lines under the IOP will need to be restarted. Tape/Optical devices under the IOP may need to be varied back on. To determine the cause of the IOP Reset/Reload, check the Product Activity Log for additional entries logged with the same System Log ID, and perform any actions indicated for those errors. A6xx5276 IOP Reset was issued
Servicer Response: System LIC detected a missing IOP LIC code l oad during IPL of the IOP. This indicates that either the IOP code load is not installed on the system load source device or that system LIC was unable to successfully read that load from the load source device. Perform LICIP01. FRU List: UG4USR1 A6xx5209 System LIC detected an IOP timeout during IOP IPL
Servicer Response: LIC has detected a problem withthe Service Processor IOP and has reset it but has not initiated reload of the Service Processor. If the load source is mirrored, some system operations may be able to continue normally. However, some system service operations have been suspended and the system should be scheduled for power down as soon as possible. Perform RTRIP08. FRU List: AJGLD01 AJDG301 FI00021 A6xx5310 System LIC program exception occurred
Servicer Response: Verify that all IOP cable connections are secure, and check tape and other non-disk devices and media to verify that they are in a ready state. Perform LICIP01. FRU List: UG4USR1 FI00130 AJDG301 A6xx5219 System LIC program exception occurred
Servicer Response: An IOP signalledto system LIC that it had entered a critical internal state. LIC automatically attempted to restart the IOP. This reference code is logged for information only. No action is required. FRU List: FI00310 FI00318 FI00065
Servicer Response: System LICdetected a logical partition configuration data consistency error. Copy the Product Activity Log data for this error and any related entries and contact your next level of hardware service support. FRU List: LPARSUP
527
A6xx5311 A6xx5350
A6xx5311 System LIC program exception occurred a valid configuration. For more information about the LPAR Validation Tool, see the following web site: http://www.ibm.com/eserver/iseries/lpar A6xx5340 Secondary partition not running at optimum.
Servicer Response: LPAR configurationdata does not match current system configuration. The system will not IPLpast DST until the problem is corrected. Following is a list of problemswhich may have caused this SRC to be reported: v Non-configured disk unit which was previously a load source on a partitioned system. v Load source configuration data does not match partition for which it is being used. v Load source configuration data does not match system serial number for which it is being used. v Load source configuration data is newer than primary partition configuration data. Perform LPRIP01. FRU List: LPARSUP A6xx5312 System LIC program exception occurred
Servicer Response: Checkthe Primary partitions Product Activity Log for system processor entries from approximately the same time. Perform the actions indicated for those entries. A6xx5341 Secondary partition not running at optimum.
Servicer Response: Checkthe primary partition Product Activity Log for system memory entries from approximately the same time. Perform the actions indicated for those entries. A6xx5342 Secondary partition not running at optimum.
Servicer Response: LPAR configurationdata informational error.The LPAR configuration data was found to be or inconsistent on a secondary partitions load source. The data was automatically updated to the current system level. A6xx5313 System LIC program exception occurred
Servicer Response: Checkthe Primary partitions Product Activity Log for system processor entries from approximately the same time. Perform the actions indicated for those entries. A6xx5343 Secondary partition not running at optimum.
Servicer Response: LPAR configurationdata informational error. The LPAR configuration data was found to be inconsistent on a primary partition and could only be corrected with an older copy of the data. FRU List: LPARCFG A6xx5320 Incorrect hardware configuration detected.
Servicer Response: Checkthe Primary partitions Product Activity Log for system memory errors from approximately the same time. Perform the actions indicated for those entries. A6xx5344 Secondary partition not running at optimum.
Servicer Response: The interactiveperformance specified in the configuration data for this partition could not be met. Contact your next level of support. FRU List: LPARSUP A6xx5350 Secondary partition software release not supported.
Servicer Response: An I/O Adapter used by a guest partition is located in a card slot on the same PCI bridge set as an I/O Processor. Guest partition data may be lost if any of the following occur: v A primary partition Type D IPL is performed. v The I/O Adapter is moved to an operating system partition. v An error causes the logical partition (LPAR) configuration to not be used. To correct the hardware configuration, either the I/O Adapter or the I/O Processor must be moved to a new location. Use the LPAR Validation Tool (LVT) to create
Servicer Response: The logical partition software version is outside the supported release delta. Check the Release Delta from the Primary partition Display Partition Release Level screen. Check the LPAR documentation for the release level of the Primary partition and determine what the supported Release Delta is.
528
A6xx5380 A6xx6907
A6xx5380 System LIC program exception occurred A6xx6902 FRU List: FI00203 AJDG301 A6xx6905 A6xx5390 System LIC program exception occurred FRU List: FI00065 LBUSADP AJDG301 A6xx6906 A6xx5505 The copying of DASD log data to the IOP log was successful High Speed Link (HSL) I/O bridge failure Optical bus failed. Contact your next level of support. Bus Expansion Adapter card failed. Contact your next level of support.
Servicer Response: Record theProduct Activity Log (PAL) hex data for this SRC or print the PAL entry. Contact your next level of support. FRU List: LPARSUP
Servicer Response: Record theProduct Activity Log (PAL) hex data for this SRC or print the PAL entry. Contact your next level of support. FRU List: LPARSUP
Servicer Response: IOP log data can be copied to a spool file for examination by the development lab. A6xx5555 SLIC I/O DASD subsystem error recovery in progress. Unrecoverable read error
Servicer Response: LIC couldnot access part of the HSL I/O bridge VPD. The bridge and HSL loop may be prevented from becoming operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event view on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIIOADP OPT_CLN
A6xx5600
Servicer Response: VPD data could not be read.Look for other errors implicating hardware. There is no way to know what VPD read has failed, but the resource is not useable and should generate an error. If no such error occurred, call your next level of support. FRU List: SVCDOCS A6xx6900 FRU List: FI00065 AJDG301 A6xx6901 FRU List: LBUSADP AJDG301 Bus Expansion Adapter card failed. Contact your next level of support. System bus error. Contact your next level of support.
A6xx6907
Servicer Response: LIC detectedinvalid data in the HSL I/O bridge VPD. The bridge and HSL loop may not have become operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view
Chapter 10. Axxx Reference Codes
529
A6xx6908 A6xx6910
you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event view on the HMC, is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIIOADP OPT_CLN A6xx6908 High Speed Link (HSL) I/O bridge failure A6xx6909 High Speed Link (HSL) I/O bridge failure
Servicer Response: LIC detectedinvalid data in the I/O bus VPD. The bus and resources associated with it may not be operational. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. If the serviceable event view only indicated a frame or enclosure see the locations section for the frame or enclosure type. The location of the HSL I/O Bridge will be given in the locations tables. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIIOADP OPT_CLN A6xx6910 I/O processor failure
Servicer Response: LIC datain the I/O bus vpd could not be accessed. The I/O Bus identified in the SRC may not have become operational. If there is a B600 6906 reference code, close this problem in the serviceable event view you are working with and work the 6906 error. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or serviceable event view on the HMC or service processor is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIIOADP OPT_CLN
Servicer Response: An I/O processor timed out,returned bad status, or is not following the system bus protocol. Perform LICIP07. FRU List: FI00310 FI00318 FI00065 FI00130 AJDG301
530
A6xx6938 A6xx6962
A6xx6938 Not valid system configuration detected item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or a serviceable event viewer on the HMC is available for this problem then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. FRU List: SLOTERR MASBUS A6xx6962 Multi-adapter bridge card slot error, do not use card slot. Power control failure, do not use slot.
Servicer Response: This systemmodel does not allow a configuration of more than three (non-OptiConnect) I/O Processors. Power down the system and remove the extra (non-OptiConnect) I/O Processor(s) so that there are three or less. Restart the system. A6xx6944 Missing or failed I/O processor cards
Servicer Response: A system busappears to be empty. If the bus is not empty, two I/O processors in consecutive slots may be missing or broken. If there are broken I/O processors, then another more serious SRC has occurred. Otherwise find the bus number for this failure from the Product activity log and use the system configuration list to verify the configuration of the I/O processors on that bus. FRU List: FI00317 FI00316 AJDG301 A6xx6960 Multi-adapter bridge card slot error, do not use cardslot. Slot unavailable due to 64 bit card in adjacent slot.
Servicer Response: Power control failure, do not use slot. If there is a LinuxTM partition in the system, any IOPs plugged into slots owned by a Linux partition will not power on. This error will be logged. Correct the situation by removing the IOP cards. The card location is not available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log, or serviceable event view on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. FRU List: SLOTERR MASBUS
Servicer Response: Slot unavailable due to 64 bit card in adjacent slot. Oneof the messages documented with the symbolic FRU will describe the problem. See the SLOTERR symbolic FRU for a list of messages and corrective actions. FRU List: SLOTERR A6xx6961 Multi-adapter bridge card slot error, do not use cardslot. LED control failure, do not use slot.
Servicer Response: LED control failure, do not use slot. The card location isnot available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing
531
A6xx6963 A6xx6967
A6xx6963 Multi-adapter bridge card slot error, do not use cardslot. Power control failure, do not use slot. 2. xxxx2014 - I/O adapters were found under the Multi-adapter Bridge but there is no IOP to support them. The adapters cannot be used. 3. xxxx2015 - An card type was found that cannot be supported in the card position where it is located. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx6965 Multi-adapter bridge configuration change or error
Servicer Response: Power control failure, do not use slot. The card location isnot available for use. The Failing Item with the card slot error is in the Failing Item list for this reference code. See the SLOTERR symbolic FRU for the list of messages and a further description of the problem detected by Licensed Internal Code. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. FRU List: SLOTERR MASBUS A6xx6964 Multi-adapter bridge configuration change or error
Servicer Response: Card type not supported in this slot. An I/O processor or I/O adapter card type is installed in the location indicated in word 7 of the SRC. The card type is not supported in that slot under the Multi-adapter bridge. The card is unavailable. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx6966 Multi-adapter bridge configuration change or error
Servicer Response: I/O processor removed from multi-adapter bridge card slot. On the previous IPL an I/O processor was in the card location specified in word 7 of the SRC. The I/O processor was not detected on this IPL. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx6967 Multi-adapter bridge configuration change or error
Servicer Response: One of several errors or configuration problems has occurred under a Multi-adapter bridge. If you are using the Service Action Log (SAL), or the serviceable event viewer on the HMC or the service processor, then the correct FRU, description and card position(s) will be listed. Use the FRUs and descriptions in the serviceable event view you are working with to determine the problem. If you do not have access to the Service Action Log, or serviceable event view on the HMC or service processor, then word 4 of the SRC has more information. Examine the last 4 digits in word 4 to determine the problem by comparing them to the list below and using the FRU(s) listed here. 1. xxxx2022 - IOP found in slots owned by a Linux partition. The Mutli-adapter Bridge and PCI Bridge set that it controls are assigned to a Linux partition. The IOP found in the SLOT indicated by the DSA in word 7 will not be configured.
System Reference Codes Volume 1, 1xxx - Axxx
Servicer Response: I/O adapter unavailable due to moved I/O processor card. The I/O adapterspecified in word 7 of the SRC is not available. On the previous IPL there was an I/O processor card the adapter was assigned to. The I/O processor was not detected on this IPL.
532
A6xx6968 A6xx6970
See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx6968 Multi-adapter bridge configuration change or error -- Using the HMC or a customer PC with a Web browser access the Advanced System Management Interface (ASMI) and disable PCI error injection policy. OR -- Vary off the I/O Adapter. Using Hardware Service manager in SST/DST, locate the I/O Adapter resource. Using concurrent maintenance on the associated packaging resource, remove the I/O Adapter and install it in a location that does not have I/O Processors on the same Multi-adapter bridge domain. OR -- Vary off the I/O Adapter. Use the concurrent maintenance option in Hardware Service Manager in SST/DST to power off all I/O Processors located on the same Multi-adapter bridge domain as the I/O Adapter. Use concurrent maintenance to power off and power on the I/O Adapter. Then use concurrent maintenance to power on the I/O Processors located on the same Multi-adapter bridge domain as the I/O Adapter. A6xx6970 High Speed Link (HSL) resource failure
Servicer Response: IOA removed from multi-adapter bridge slot. On the previous IPL an I/O adapter was in the card slot specified in word 7 of the SRC. That I/O adapter was not detected on this IPL. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx6969 Multi-adapter bridge configuration change or error
Servicer Response: I/O adapter replaced by I/O processor card. On the previous IPL there was an I/O adapter in the location specified in word 7 of the SRC. This IPL LIC detected that the IOA was replaced by an IOP in that location. See the MABRCFG symbolic FRU for the list of messages, a further description of the problem detected by Licensed Internal Code and the corrective action. FRU List: MABRCFG A6xx696A Card slot test failed
Servicer Response: A system PCIbus failure was detected. Word 7 of the SRC contains the bus number. This failure can occur when a tower in an HSL loop is powered off using concurrent maintenance. If this is the case, close this problem. This error is most likely in the hardware that makes up the PCI bus, the PCI bus side of the HSL I/O bridge or the multi-adapter bridge. In some cases it may be caused by a failing IOP in the multi-adapter bridges domain. When an IOP is causing the problem, the failing IOP cannot be identified. NOTE: This SRC can occur for the PCI bus resource on a PCI bus in an I/O expansion unit when the unit is powered off for a concurrent maintenance action. Exchange the failing items, one at a time, in the order they are listed in the serviceable event view or this document until you get to the BRDGSET or BRDGSTx symbolic FRU. If the problem still exists after exchanging the failing items up to, but not including, BRDGSET or BRDGSTx then perform MABIP03 to determine the failing I/O processor card. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed.
Servicer Response: Perform LICIP14. FRU List: FI00131 BACKPLN A6xx696B Card slot could not be validated
Servicer Response: This can be causedby PCI error injection policy being set to YES and an I/O Processor being installed on the same Multi-adapter bridge domain as the I/O Adapter. Do one of the following:
533
A6xx6971 A6xx6974
If the Service Action Log, or serviceable event view on the HMC or service processor, is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SI_PHB PRI_PCI MA_BRDG BRDGSET OPT_CLN A6xx6971 High Speed Link (HSL) resource failure A6xx6972 High Speed Link (HSL) resource failure
Servicer Response: Multi-adapterBridge (MaB) failure detected. For this reference code the failing item list presented in the Service Action Log (SAL), or serviceable event viewer you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. FRU List: MA_BRDG A6xx6973 High Speed Link (HSL) resource failure
Servicer Response: Failure ina multi-adapter bridge or on the bus to the card location it controls. For this reference code the failing item list presented in the Service Action Log (SAL) or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or serviceable event viewer is available then use the failing item list presented there for servicing this reference code. If a serviceable event view is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. Perform MABIP02. FRU List: MA_BRDG MASBUS PIOCARD
Servicer Response: Multi-adapterBridge has detected a problem in the card installed in the location specified in word 7 of the SRC. Use the FRU list in the Service Action Log (SAL), or serviceable event view you are working with. If you are working from this documents FRU list use the Symbolic FRU BRDGSET to determine the failing items. FRU List: BRDGSET SIIOADP MA_BRDG A6xx6974 Multi-adapter bridge configuration change or error
Servicer Response: PCI I/O processor rejected the assignment of or the removal of an I/O adapter. The direct select address in word 7 of the SRC specifies the location of the IOA. The direct select address of the IOP is in word 5 of the SRC. See the DSA translation table and the Card positions table to determine the card locations for the IOA and the IOP. Use slot concurrent maintenance under HSM to assign or remove the IOA. FRU List: MABRCFG
534
A6xx6975 A6xx6983
A6xx6975 The system issued a reset/reload to the service processor If you find either a B600 6982 or B600 6984 SRC logged at approximately the same time as this SRC then they were caused by the same failure. If you find a 6982 SRC logged at approximately the same time then close this problem and service the 6982 SRC. The failing item listed for this SRC is one of the failing items listed for B600 6982. If the serviceable event views entry for this SRC has a location listed then record the location for use in servicing the 6982 SRC. NOTE: This SRC can occur for the HSL I/O Bridge resource in an I/O expansion unit when the unit is powered off for a concurrent maintenance action. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIIOADP OPT_CLN A6xx6982 High Speed Link (HSL) connection failure
Servicer Response: Service processor error. FRU List: AJDGP01 A6xx6976 Service processor failure
Servicer Response: For this reference codethe failing item list presented in the Service Action Log (SAL), or serviceable event view you are working with, can be different from the failing item list documented here. That is due to the differences in system models and features installed. If the Service Action Log (SAL) or a serviceable event viewer on the HMC is available then use the failing item list presented there for servicing this reference code. If a serviceable event viewer is not available then use the failing item list documented here. By following the procedures in the symbolic FRUs listed here you will isolate to the correct FRU list based on system model and features installed. FRU List: SVCPROC A6xx6980 Network Interface Controller (NIC) resource failure
Servicer Response: If thisSRC is not in the Service Action Log (SAL), or serviceable event view you are using, then it is informational and/or statistical only. It does not require a service action. Otherwise: This is a connection failure on an HSL link. Perform RIOIP09 to determine the service action. FRU List: HSL_LNK SIIOADP SICNTRL REM_NIC OPT_CLN A6xx6983 An invalid High Speed Link (HSL) configuration was detected
Servicer Response: The FRU list displayed in the Service Action Log (SAL) or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SICNTRL OPT_CLN A6xx6981 High Speed Link (HSL) I/O bridge failure
Servicer Response: Cycle poweron the frame identified as the frame with failed HSL I/O Bridge prior to replacing FRUs. The FRU list displayed in the Service Action Log (SAL), or serviceable event view you are using, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you.
Servicer Response: An HSL loop has an invalid configuration. Word 4 of the SRC contains the program return code (PRC) which identifies the problem with the loops configuration. Use the PRC and the FRU listed to determine the problem. If you are using the Service Action Log (SAL) or serviceable event view you are working with, the FRU description may already indicate the configuration problem. FRU List:
Chapter 10. Axxx Reference Codes
535
A6xx6984 A6xx6986
SIRGCFG A6xx6984 High Speed Link (HSL) loop status message here. (HSL_LNK or HSLxxxx FRU in the Service Action Log (SAL) entry, or serviceable event view you are working with, indicates the loop number.) If there are other system(s) then continue with the steps that follow, otherwise go to step 2. v Check for HSL failures on the other system(s) before replacing parts. HSL failures are serviceable event entries with HSL I/O Bridge and Network Interface Controller (NIC) resources. Ignore B600 6982 and B600 6984 entries. If there are HSL failures on other system(s) then continue with the steps that follow, otherwise go to step 2. v Repair the problems on the other systems and return to this step. After making repairs on the other system(s) check the Product Activity Log (PAL) of this system for a B600 6985 logged after the repairs you made on the other system(s). If you find one then continue with the steps that follow, otherwise go to step 2. v For the B600 6985 log you found, use FRU SIRSTAT to determine if the loop is now complete. If the loop is complete then this problem has been resolved. Use RIOIP01 to verify that the loop is now working properly. Otherwise, go to step 2. 2. Use the serviceable events FRU list when it is available. If this SRC appears in the Service Action Log (SAL), or the serviceable event view you are using, with the Symbolic FRU HSL_LNK or HSLxxxx listed as a FRU, then perform problem isolation procedure RIOIP01. Otherwise exchange the FRUs listed in the serviceable event view. NOTE: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SIRSTAT HSL_LNK SIIOADP SICNTRL OPT_CLN A6xx6986 System bus error
Servicer Response: An HSLloop has switched to its alternate path. This is an informational SRC only. Word 7 of the SRC contains the loop number in the leftmost 4 digits. The loop number is in hexadecimal format. You must convert the hexadecimal loop number into decimal format to recognize the loop number in HSM. This SRC can be caused by a tower on the HSL loop powering off. This SRC may also appear in the Service Action Log (SAL), or serviceable event viewer you are using, with a B600 6982 or B600 6981 logged at approximately the same time. In that case the other SRC is reporting a failure and this SRC is reporting that the alternate HSL path is now being used. Service the other SRC if present. A6xx6985 High Speed Link (HSL) loop status message
Servicer Response: If thisSRC is not in the Service Action Log (SAL), or serviceable event view you are using, then it is informational. Use FRU SIRSTAT to determine what this SRC means. Otherwise, continue with the following steps: This error can appear as a serviceable event when a tower, or I/O unit or another system in the loop did not complete powering on before LIC on this system checked this loop for errors. Search the Product Activity Log (PAL) for the last B600 6985 SRC logged for this loop and use FRU SIRSTAT to determine if this error requires service. If the last entry indicates the loop is functioning (determined by FRU SIRSTAT) then no service action is required, close this problem There may be multiple B600 6985 logs with xxxx 3205 in word 4 errors for the same loop resource in the serviceable event view. This is caused by retry and recovery attempts. If there is a B600 6985 with xxxx 3206 or xxxx 3208 in word 4 after the above B600 6985 entries in the PAL, then the recovery efforts were successful. If this is the case, close all the B600 6985 entries for that loop resource in the serviceable event view. 1. If you find a B600 6981 in the serviceable event view then close that problem and go to step 2. Otherwise perform the following: v Perform RIOIP06 to determine if any other systems are connected to this loop and return
Servicer Response: During IPL, system LIC detectedan HSL I/O bridge that was already initialized. The bridge should have been in a flushed and unintialized state after powering on. There is a problem with SPCN components that prevented the tower from powering off after a previous power off was issued. The tower will not be configured for this IPL.
536
A6xx6987 A6xx69A8
This reference code is equivalent to 1xxx 90F0. When referring to the CBLALL symbolic FRU in the Failing Item list, perform the CBLALL procedure using reference code 90F0. Word 5 of the SRC identifies the frame. Determine the frame by breaking down word 5: Word 5 -> xxxx xxNN where: NN is the frame number in hexadecimal format. FRU List: TWRCARD CBLALL A6xx6987 High Speed Link (HSL) connection failure vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. FRU List: SVCPROC A6xx6991 FRU List: AJDGP01 A6xx6992 FRU List: AJDGP01 A6xx6993 Service processor failure Service processor failure Service processor failure
Servicer Response: Failures are occurring on the HSL link. There may be B600 6982 errors logged on the same loop and about the same time as this error. Close those errors and continue to correct the problem by working this error. v If there is a cable FRU in the serviceable event entry: 1. If the connection is copper and either end has a loose connection, reseat the cable. To do this, disconnect the connection and wait a minimum of 30 seconds. Then reconnect the cable and complete the tightening process in at most 30 seconds. Repeat the process at the other end of the cable. If the error persists, replace the FRUs in the Service Action Log (SAL), or serviceable event view you are using. 2. If the connection is optical, clean the connections at both ends of the cable. See OPT_CLN OPT_CLN . If the error persists, replace the FRUs in the Service Action Log (SAL), serviceable event view you are using. 3. If the error persists, replace the FRUs at each end of the cable starting with the FROM FRU listed in the serviceable event view you are using. v If there was no cable in the Service Action Log (SAL), or serviceable event view you are using, then replace the FRUs listed in the serviceable event view. FRU List: HSL_LNK OPT_CLN OPT_CLN A6xx6990 Service processor failure
Servicer Response: A failure occurred withthe service processor hardware or the service processor LIC. The FRU list displayed in the Service Action Log (SAL), or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. FRU List: SVCPROC AJDGP01 A6xx6994 Service processor failure
Servicer Response: The FRU list displayedin the Service Action Log (SAL) or serviceable event view you are working with, may vary from the failing item list given in this document. Use the FRU list in the serviceable event view if it is available to you. FRU List: SVCPROC A6xx699C Wrap plug is installed on Bus Expansion Adapter card
Servicer Response: This reference code is for information only. It indicates the presence of a wrap plug on the local optical link card. A6xx69A8 Informational bus reference code
Servicer Response: The FRU list displayedin the Service Action Log (SAL), or serviceable event view you are working with, may
Servicer Response: This reference codeis for information only and might include the following: v Optical speed encode v Broken optical links now operational v Other information
537
A6xx69B8 A6xx69C7
A6xx69B8 FRU List: FI00187 AJDG301 A6xx69C1 FRU List: FI01040 FI00206 FI00182 AJDG301 A6xx69C2 Information only, no service action required. HSL OptiConnectnormal connection to another system or partition. A failure occurred on another system. Contact your next level of support. Bus hardware configuration problem. Contact your next level of support. A6xx69C6 Abnormal or unexpected HSL OptiConnect disconnectionfrom a remote system or partition.
Servicer Response: The local system or partition disconnectedfrom a remote system or partition due to an unexpected event or failure. The problem is most likely with the remote system or partition. Intervention at the remote system is most likely required. Examine both the local and remote HSL OptiConnected systems or partitions for problems on this HSL loop. Possible reasons include: A fatal error in software or hardware in the remote system or partition or a power failure in the remote system. If there was not a complete HSL loop before this error occurred then a failure or power down in an HSL component between the local system or partition and the remote system or partition could have caused this error. Check for a problem with: an HSL cable, HSL I/O bridge or a power problem in an expansion I/O tower or unit on this loop. Examine the Service Action Log (SAL), or serviceable event view you are using on the local system or partition for HSL failures on the same HSL loop at approximately the same time this error occurred. Examine the remote system or partition for problems. If the remote system or partition is powered on and IPLd then examine the Service Action Log (SAL), or serviceable event view you are using, on the remote system or partition for problems on the same HSL loop at approximately the same time this error occurred. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. When the remote system is IPLd it will automatically reconnect with this system or partition. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. FRU List: REM_SYS A6xx69C7 Abnormal or unexpected HSL OptiConnect disconnectionfrom a remote system or partition.
Servicer Response: This reference codeis informational only. HSL OptiConnect has established connection normally. The local system or partition is participating in HSL Opticonnect with other systems or partitions on the same HSL loop. A6xx69C3 Information only, no service action required. Opticonnectnormal remote disconnection from OptiConnect participation.
Servicer Response: This referencecode is informational only. HSL Opticonnect disconnected normally from a remote node. The local system or partition has stopped participating in HSL Opticonnect with the remote system or partition on the same HSL loop. Possible reasons include: v A remote system or partition went off line due to a normal power off or disable of HSL Opticonnect. A6xx69C5 FRU List: FI00206 FI01040 AJDG301 I/O processor failure. Contact your next level of support.
Servicer Response:
538
A6xx69C8 A6xx69C9
The local system or partition disconnectedfrom a remote system or partition due to an unexpected event or failure. LIC will attempt to recover from the error. Intervention at the local or remote system or partition may be required. Possible causes are: time out, hang or hardware failure. The problem may be with: the local system or partition or the remote system or partition. If there was not a complete HSL loop before this error then a failure or power down in an HSL component between the local system or partition and the remote system or partition could have caused this error. Check for SRCs with FRUs like: HSL cables, HSL I/O bridge or a power problem in an expansion I/O tower or unit on this loop. Examine the SAL or serviceable event view you are working with on the local system or partition for failures on the same loop, or with the Network Interface Controller at approximately the same time. Examine the remote system or partition for problems. Correct any HSL or NIC problems you find with the remote and local systems or partitions. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log (PAL) information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. FRU List: REM_SYS LOC_SYS A6xx69C8 Abnormal or unexpected HSL OptiConnect disconnectionfrom a remote system or partition. Examine the Service Action Log (SAL), or serviceable event view you are using, on the local system or partition for HSL failures on the same HSL loop, or with the Network Interface Controller at approximately the same time this error occurred. Examine the remote system or partition for problems. Examine the Service Action Log (SAL), or serviceable event view you are using, on the remote system or partition for problems on the same HSL loop or with the Network Interface Controller at approximately the same time this error occurred. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on all systems or partitions. Be sure to record all words in the SRCs. Contact your next level of support. FRU List: REM_SYS LOC_SYS AJDG301 A6xx69C9 Abnormal or unexpected HSL OptiConnect disconnectionfrom a remote system or partition.
Servicer Response: The local system or partition disconnectedfrom a remote system or partition due to an failure in a LIC virtualized bus unit. LIC will attempt to recover from the error. Possible causes are: v LIC problem where the local bus unit is off line. v LIC problem where the remote bus unit is off line. Examine the Service Action Log (SAL), or serviceable event view you are using, on the local system or partition for HSL Opticonnect failures that occurred at approximately the same time this error occurred. Examine the remote system or partition for problems. Examine the Service Action Log (SAL), or the serviceable event view you are using, on the remote system or partition for HSL Opticonnect problems that occurred at approximately the same time this error occurred. Collect all the Product Activity Log information for this failure on all systems and partitions on this HSL loop.
Servicer Response: The local system or partition disconnectedfrom a remote system or partition due to an unexpected event or failure. All of the HSL OptiConnect connections on this loop will be in a failed state. LIC will attempt to recover from the error. Intervention at the local or remote system or partition may be required. Possible causes are: v time out of a critical message v LIC code / table problem v Network deadlock detected The problem may be with: v The local system or partition v The remote system or partition
539
A6xx69CF A6xx69DE
Be sure to record all words in the SRCs. Contact your next level of support with the information you have collected. FRU List: AJDG301 REM_SYS LOC_SYS A6xx69CF Abnormal or unexpected HSL OptiConnect disconnectionfrom a remote system or partition. LBUSADP AJDG301 A6xx69D9 Host Ethernet Adapter (HEA) failure.
Servicer Response: Firmware detected a hardware failure in the Host Ethernet Adapter (HEA). FRU List: HEA A6xx69DA System log entry only, no service action required.
Servicer Response: LIC internal error. All systems participatingin HSL OptiConnect will be disconnected. The system must be re-IPLd to recover. Before re-IPLing the system initiate a main store dump. After getting the dump, examine the Service Action Log (SAL), or serviceable event view you are using, on the local system or partition for HSL Opticonnect failures that occurred at approximately the same time this error occurred. Examine the remote systems or partitions for problems. Examine the Service Action Log (SAL), or serviceable event view you are using, on the remote systems or partitions for HSL Opticonnect problems that occurred at approximately the same time this error occurred. Collect all the Product Activity Log information for this failure on all systems and partitions on this HSL loop. Be sure to record all words in the SRCs. Contact your next level of support with the information you have collected. FRU List: AJDG301 A6xx69D0 FRU List: FI00182 FI00055 AJDG301 A6xx69D8 FRU List: FI00182 FI00203 FI00055 Bus Expansion Adapter failed. Contact your next level of support. Bus Expansion Adapter card failed. Contact your next level of support.
Servicer Response: System log entry only, no service action required A6xx69DB LIC failure. A Licensed Internal Code error occurred.
Servicer Response: The partition will continue to run with this Host Ethernet Adapter (HEA) disabled. Perform a partition dump and then IPL the partition to recover the HEA. Send the partition dump to your next level of support. A6xx69DC The HEA is not connected to the Ethernet switch.
Servicer Response: The Host Ethernet Adapter (HEA) is not connected to the Ethernet switch. If the HEA connection is not needed, no service action is required. If the HEA connection is needed, verify that the cable is connected and the switch is powered on. After repairing the problem, verify that the connection has been restored. A6xx69DD The HEA connection to the Ethernet switch has been restored.
Servicer Response: System log entry only, no service action required. A6xx69DE HEA Media Interface Adapter Failure.
Servicer Response: Firmware detected a failure in the HEA Media Interface Adapter. FRU List: HEA AJDG301
540
A6xx69E0 A6xx7100
A6xx69E0 Bus Expansion Adapter card failed A6xx7001 FRU List: GG4COMM A6xx7002 FRU List: GG4COMM Bus Expansion Adapter failed. Contact your next level of support. A6xx7003 FRU List: GG4COMM A6xx7004 TCP/IP informational error Network interfaces not selected Lines not selected ISDN call in rejected
Servicer Response: Contact your nextlevel of support. FRU List: FI00203 AJDG301 A6xx69E8 FRU List: FI00203 FI00205 FI00057 AJDG301 A6xx69F0 FRU List: FI00180 FI00182 FI00203 FI00056 FI00205 LBUSADP AJDG301 A6xx69F8 FRU List: FI00180 FI00203 FI00182 FI00186 FI00057 AJDG301 Bus Expansion Adapter failed. Contact your next level of support. Bus Expansion Adapter failed. Contact your next level of support.
Servicer Response: This reference code islogged when the TCP/IP Attribute Log Protocol Errors is set, and the TCP/IP System LIC silently discards an inbound datagram. Silently discard is defined to mean discard the received datagram without reporting an error to the originating host device. Examples of such datagrams are those with checksums or destination addresses which are not valid. This reference code is for information only. Normally no action should be taken as a result of this reference code. It is generated in order to assist with remote device or TCP/IP network problem determination. A6xx7055 Statistics were logged, no service action required
Servicer Response: This reference code is logged for information only. A6xx7100 APPN session initiation attempt has timed out.
Servicer Response: Thisreference code is used to indicate that LIC timed out on a request to initiatea session. The user must run problem analysis for this reference code. If this indicates a software problem, the user should dial IBM Software Support for assistance. The Problem Determination Procedure (PDP) will indicate whether the original timeout condition still exists and what the corrective actions should be. FRU List: AJDG301 GG4PL03 GG4PL01 GG4PL02
Chapter 10. Axxx Reference Codes
541
A6xx7101 A6xx7701
A6xx7101 APPN session initiation attempt has failed A6xx7205 Battery low condition was reset.
Servicer Response: This referencecode is used to indicate that LIC attempted to satisfy a session initiationrequest, but some failure condition was detected by LIC. The failure conditioncould be a configuration or operational problem in the network. Theuser must run problem analysis for this reference code. If this indicates a software problem, the user should dial IBM Software Support for assistance. The Problem Determination Procedure (PDP) will indicate whether the original timeout condition still exists and what the corrective actions should be. FRU List: GG4PL04 GG4PL05 GG4PL06 AJDG301 A6xx7102 A6xx7201 APPN CP-CP session ended. A utility failure occurred.
Servicer Response: This reference codeis for information only. The Uninterruptible Power System (UPS) is no longer reporting a battery low condition. A6xx7206 UPS reported bypass no longer active
Servicer Response: This referencecode is for information only. The Uninterruptible Power System (UPS) is no longer reporting a bypass active condition. A6xx7207 Battery Power Unit needs service
Servicer Response: The replacementperiod for BPU 1, installed in the System Unit, has been exceeded. FRU List: FI00315 A6xx7208 Battery Power Unit needs service
Servicer Response: The replacementperiod for BPU 2, installed in the System Unit, has been exceeded. FRU List: FI00315 A6xx7209 Battery Power Unit needs service
Servicer Response: This reference code isfor information only. The Uninterruptible Power System (UPS) is reporting a utility failure. A6xx7202 Utility power restored.
Servicer Response: The replacementperiod for BPU 1, installed in the Expansion Unit, has been exceeded. FRU List: FI00315 A6xx720A Battery Power Unit replacement dates do not match
Servicer Response: This reference code is forinformation only. The Uninterruptible Power System (UPS) is reporting that utility power has been restored. A6xx7203 A battery low condition was detected.
Servicer Response: This referencecode is for information only. The Uninterruptible Power System (UPS) is reporting a battery low condition. A6xx7204 Uninterruptible Power System reported a bypass active
Servicer Response: The replacement dates for one of the Battery Power Units do not match. Run Display Hardware Configuration and verify that the dates match the labels on the batteries. A6xx7701 FRU List: 21H7625 BACKPLN SCSI jumper card was not detected.
Servicer Response: This reference code is for information only. The Uninterruptible Power System (UPS) is reporting a bypass is active.
542
A6xx7702 A6xx8007
A6xx7702 FRU List: 21H7625 A6xx7703 System LIC detected a program exception Incorrect SCSI jumper card detected A6xx8002 Maximum number of redundant connections exceeded
Servicer Response: An attempt to activate a connection from another I/O adapter to an external storage subsystem disk unit failed because the maximum number of connections are already active for this disk unit. No action required. A6xx8003 External storage subsystem disk unit connection wasrestored. No action required. An external storage subsystem disk unit connection failed
Servicer Response: Storage Managementdetected a DASD datacheck condition and the defective sector was reallocated. Perform a system IPL to restart the system. A6xx7704 FRU List: AJDG301 A6xx7777 Hardware configuration change detected General failure detected by HRI component.
A6xx8004
Servicer Response: A hardwareresource is missing. The resource reported in to the system on a previous IPL, but has not reported in on the current IPL. This could occur for several different reasons. 1. It could be a normal situation where the resource is currently powered off. In this case, when the resource is powered back on, it will no longer be missing. 2. The hardware resource could also be missing if it has been removed from the system, for example, a tape drive that was replaced with a different tape drive. The service representative should use the Hardware service manager to remove the entry for this resource. 3. The resource may not have reported in on this IPL because it is failing. Perform problem analysis to determine why the resource is failing. A6xx8000 An external storage subsystem disk unit connection failed
Servicer Response: Could not read configuration information from the disk unit. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. A6xx8005 High performance connection failed.
Servicer Response: A high performanceconnection to an external storage subsystem disk unit failed. There are still two or more external storage subsystem disk unit connections, but performance might be degraded. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. A6xx8006 High performance connection failed
Servicer Response: A high performanceconnection to an external storage subsystem disk unit failed. There is still one more external storage subsystem disk unit connection, but performance might be degraded. Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them. A6xx8007 High performance connection was restored
Servicer Response: Look for other errors in the Service Action Log (SAL), or serviceable event view you are working with, and fix them. A6xx8001 An external storage subsystem disk unit connection failed
Servicer Response: Look for other errors in the Service Action Log, or serviceable event view you are working with, and fix them.
Servicer Response: A high performanceconnection to an external storage subsystem disk unit was restored. Performance is no longer degraded. No action required.
543
A6xxCF00 A7xx0103
A6xxCF00 A6xxCFFC Permanent error on optical device. Optical library device condition not expected Servicer Response: The hypervisor terminated a partition with an unresponsive Operating System. A Main Store Dump must be done for service. Call your next level of support when the dump is complete. Perform LICIP01. A6xxF105 FRU List: NEXTLVL A6xxFDC0 LIC program reported informational error Licensed Internal Code detected error
Servicer Response: Theoptical disk drive addressing within the optical library is incorrect. This error is likely to be the result of faulty cabling or switch setting following service to an optical library. Contact your hardware service provider. FRU List: OPTLCBL DRVSWCH A6xxCFFD FRU List: OPTLDRV A6xxCFFF Media determined to be bad in Optical library Main storage dump must be copied for service. Optical drive failure
Servicer Response: This referencecode is logged for information only. No action required. A6xxFDC5 LIC program failed and data was captured
Servicer Response: This referencecode indicates first failure data capture (FFDC) data was collected for a problem reported by licensed internal code. The user should dial IBM Software Support for assistance. FRU List: GG4FFDC
A6xxF103
Servicer Response: Perform LICIP01. A6xxF104 Logical partition service function Main Storage Dump.
Servicer Response: A machine check occurredduring IPL. Words 2 to 9 of this SRC contain additional diagnostic information. Record SRC words 1 through 9 before attempting to IPL again and report the problem to next level of support. FRU List: SVCDOCS
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform Licensed Internal Code (LIC) detected an internal problem. Collect all the SRC words and the platform system dump, then contact your next level of support. FRU List: LICCODE
544
A7xx0104 A7xx0602
A7xx0104 Platform LIC failure A7xx0302 Platform LIC failure
Servicer Response: Machine check, undefined erroroccurred. FRU List: LICCODE A7xx0105 Platform LIC detected an error
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Perform a platform system dump and notify your service provider. IPL the system. FRU List: LICCODE A7xx0441 Service processor failure
Servicer Response: More than one requestto terminate the system was issued. FRU List: NEXTLVL A7xx0106 Platform LIC failure
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. A secondary failure due to an invalid SRC occurred when the platform attempted to terminate. Collect all the SRC words and the platform system dump, then contact your next level of support. FRU List: LICCODE A7xx0107 Platform LIC failure
Servicer Response: Work with the FRU listin the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform encountered an error early in the IPL or termination process. FRU List: SVCPROC NEXTLVL A7xx0443 FRU List: SVCPROC NEXTLVL A7xx0601 System log entry only, no service action required Service processor failure
Servicer Response: The server detected an unrecoverablemachine check condition. Collect all the words of the SRC and the platform dump and send to your system manufacturer for analysis. FRU List: SVCDOCS A7xx0200 System firmware has experienced a low storage condition.
Servicer Response: Support can use this SRC and associated data to determine why the time of day for a partition was lost. No corrective action is required. A7xx0602 Platform LIC detected an error
Servicer Response: No immediate action is necessary. Continue running the system normally. At the earliest convenient time or service window work with your service provider to take a platform dump and reIPL the system. FRU List: SVCDOCS A7xx0201 System log entry only, no service action required.
Servicer Response: Work with the FRUlist in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Platform Licensed Internal Code (LIC) detected an error condition. The second word indicates the severity of the error and the specific error condition. If word 2 is 10000A01 then record the SRC words and call your next level of support; otherwise this does not require service. FRU List: NEXTLVL
545
A7xx0611 A7xx1152
A7xx0611 System clock problem If the system did not log this error as a serviceable event, then no service action is required. FRU List: CLCKMOD A7xx0803 For systems managed by an HMC, use the ASM interface to reset the system clock at power on standby. For systems without an HMC, you can ignore this error. If the error occurs a second time, call your next level of support. FRU List: SVCDOCS A7xx0621 System log entry only, no service action required System log entry only, no service action required. System log entry only, no service action required. System log entry only, no service action required
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange.
A7xx0804
A7xx0A00
Servicer Response: A user request initiated an I/O tower/drawer power off. No corrective action is required. A7xx0A10 System log entry only, no service action required
Servicer Response: No service action required. A7xx0641 Platform LIC detected an error.
Servicer Response: A platform LIC failure occurred. Perform a platform dump and contact your next level of support. FRU List: SVCDOCS A7xx0650 Platform LIC detected an error
Servicer Response: No action is required, unless the Hardware Management Console (HMC) indicates that the concurrent platform firmware update failed. In that case, the system must be re-IPLed in order for the firmware update to occur. Collect the error log data for this SRC and contact PHYP development to debug the problem. A7xx1150 System log entry only, no service action required.
Servicer Response: Resource managementwas unable to allocate main storage. A platform dump was started. Words 2 to 9 of this SRC contain additional diagnostic information. Record SRC words 1 through 9. Collect the platform dump and the configuration of the memory allocation for all partitions on this system. Provide the platform dump, configuration data, and the recorded SRC information to your next level of support. FRU List: NEXTLVL A7xx0651 The system detected an error in the system clock hardware
Servicer Response: No action needed unless a serviceable event was logged. If a serviceable event was logged, resolve that error. A7xx1151 System log entry only, no service action required.
Servicer Response: No action needed unless a serviceable event was logged. If a serviceable event was logged, resolve that error. A7xx1152 Platform firmware detected a timeout condition. A reset/reload of the service processor has cleared the timeout condition.
Servicer Response: This is a serviceable event only if this error appears in a serviceable event view. If this is a serviceable event, then work with the FRU list in the serviceable event view if there is one. Otherwise, use the FRU list documented in the Failing Items column to determine the parts to exchange.
Servicer Response: If a service processor dump exists, it should be collected for IBM Service. This SRC means that there was an FSP mailbox message timeout (high level timeout). This error may be logged either as Serviceable or as Informational:
546
A7xx1160 A7xx173B
v Serviceable - a command timeout occurred waiting for the FSP to respond. This error will be logged just prior to requesting an FSP reset/reload. v Informational - an outstanding mailbox command was cancelled due to a reset/reload occurring. Note: The offending mailbox message Type/Subtype/Modifier is in SRC word 6. FRU list:: NEXTLVL A7xx1160 Service processor failure A7xx1731 Platform LIC detected an error
Servicer Response: The VPD for the systemis not what was expected at IPL. The VPD on a memory DIMM is not correct and the memory on the DIMM cannot be used, resulting in reduced memory. Work with the FRU list in the serviceable event view, if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. FRU List: MEMDIMM A7xx1732 Platform LIC detected an error
Servicer Response: Work with the FRU listin the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform encountered an error communicating with the service processor. The platform code attempts a graceful shutdown of partitions and powers off the server after a certain time, or when the last partition indicates shutdown, whichever comes first. FRU List: SVCPROC LICCODE A7xx1161 System log entry only, no service action required
Servicer Response: The VPD for the systemis not what was expected at IPL. The VPD on a processor card is not correct and the processor card cannot be used, resulting in reduced processing power. Work with the FRU list in the serviceable event view if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. FRU List: ANYPROC A7xx1733 Platform LIC detected an error
Servicer Response: The platform encountered a service processor event indicating that the power status has changed. Note that this is A7xx only. A7xx1730 Platform LIC detected an error
Servicer Response: If required Capacityon Demand functions are not available, re-IPL the system. Otherwise, no service action is required. A7xx173A System log entry only, no service action required
Servicer Response: The VPD for the systemis not what was expected at IPL. When word 9 is 00180003, a redundant VPD chip exists, and the system will continue to run. Replace the VPD card at your next scheduled maintenance. When word 9 is not 00180003 replace the VPD card immediately. Work with the FRU list in the serviceable event view, if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. FRU List: CAPACTY
Servicer Response: A VPD collection overflow occurred, no service action required. If a system problem is suspected, look for other errors in the serviceable event view. A7xx173B Platform LIC detected an error
Servicer Response: A platform LIC failureoccurred during VPD collection. Look for and correct errors with SRCs of the form B1xxxxxx in the Serviceable Event View. If that does not correct the problem, contact your next level of support. FRU List: SVCDOCS
547
A7xx4091 A7xx4710
A7xx4091 User intervention required SVCDOCS CAPACTY A7xx4701 Platform LIC detected an error
Servicer Response: The system power on hasreached a standby state. The firmware does not have partition configuration information. Use the Hardware Management Console (HMC) to activate one or more partitions to change the system from a standby state to an operating state. If the HMC does not manage the server, perform Restoring your server to factory settings . A7xx4400 There is a platform dump to collect
Servicer Response: A problem occurredwhen initializing, reading, or using system VPD. The IPL failed. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: CAPACTY A7xx4703 Platform LIC failure
Servicer Response: Work with theFRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Use the operating systems interface designated to collect platform dumps. FRU List: SVCDOCS A7xx4401 Platform LIC failure
Servicer Response: A problem occurred when initializing,reading, or using system VPD. The Capacity on Demand function is not available. If Capacity on Demand function is required, re-IPL the system. If that does not correct the problem, contact your next level of support. FRU List: LICCODE A7xx4704 Platform LIC detected an error
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform LIC detected an internal problem. Contact your next level of support. FRU List: NEXTLVL A7xx4402 Platform LIC failure.
Servicer Response: The Capacity on Demandfunction is no longer available. If Capacity on Demand functions are required, look for and correct errors with SRCs of the form B1xxxxxx in the Serviceable Event View. If that does not correct the problem, or no errors were found, contact your next level of support. FRU List: SVCDOCS A7xx4705 Platform LIC failure
Servicer Response: A platform LIC error occurred while attempting to allocate the memory necessary to create a platform resource dump. FRU List: NEXTLVL A7xx4700 Platform LIC detected an error
Servicer Response: A problem occurred when initializing,reading, or using system VPD. The Capacity on Demand function is not available. If Capacity on Demand function is required, re-IPL the system. If that does not correct the problem, contact your next level of support. A7xx4710 Platform LIC detected an error
Servicer Response: A problem occurredwhen initializing, reading, or using system VPD. Capacity on Demand is not available because the stored activation code is not valid. Contact your next level of support to verify your activation code. If the activation code is valid, replace the VPD card. FRU List:
Servicer Response: A communications problemwith the service processor occurred while initiating Capacity on Demand. The Capacity on Demand function is not available. If Capacity on Demand function is required, look for errors with SRCs of the form B1xxxxxx or B7xx69xx in
548
A7xx4712 A7xx4733
the Serviceable Event View. Work those errors. If that does not correct the problem, contact your next level of support. FRU List: SVCDOCS A7xx4712 Platform LIC detected the VPD card is missing A7xx4716 User intervention required
Servicer Response: The Capacity on Demandactivation code recovery period has been started. Either obtain more capacity by obtaining new activation codes or allocate fewer resources in the LPAR configuration. FRU List: SVCDOCS LPARCFG A7xx4721 The World-Wide Port Name (WWPN) Prefix is not valid.
Servicer Response: A problemoccurred when initializing, reading, or using system VPD. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: CAPACTY A7xx4713 Platform LIC detected an error
Servicer Response: The VPD card has beenexchanged with a not valid card. Reinstall the original VPD card in the system. FRU List: SVCDOCS A7xx4714 Platform LIC has detected a new VPD card
Servicer Response: Contact your hardware service provider to obtain a valid World-Wide Port Number (WWPN). Once you have obtained a valid WWPN value, go to ASM and select: System_Configuration-> Program_Vital_Product_Data-> System_Keywords. On the System_Keyword menu, enter the value for the WN keyword. FRU List: SVCDOCS A7xx4730 Platform LIC detected an error
Servicer Response: The newVPD card requires new activation codes. Enter the new activation codes. FRU List: SVCDOCS A7xx4715 Platform LIC detected an error
Servicer Response: A problem occurredwhen configuring the logical partitions on the system. More resources were allocated than there are available for use. Either obtain more capacity by obtaining new activation codes or allocate fewer resources in the LPAR configuration. FRU List: SVCDOCS LPARCFG A7xx4731 Platform LIC detected an error
Servicer Response: A problem occurredwhen initializing, reading, or using system VPD. Look for errors with SRCs of the form B1xxxxxx in the Serviceable Event View. Work those errors first. If that does not correct the problem, replace the VPD card. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: SVCDOCS CAPACTY
Servicer Response: The system has beenrunning with full Capacity on Demand resources activated. In one hour, the system will terminate and unlicensed resources will no longer be available. To prevent the system from terminating, enter an activation code of all zeroes. Then obtain the proper activation codes for the resources being used or allocate fewer resources in the LPAR configuration. FRU List: SVCDOCS A7xx4733 Platform LIC failure
Servicer Response:
549
A7xx4740 A7xx47FF
The Capacity on Demand functionis not available. If Capacity on Demand function is required, re-IPL the system. If that does not correct the problem, contact your next level of support. A7xx4740 Platform LIC detected an error A7xx4749 User intervention required
Servicer Response: One hour remains untilthe Trial Customer on Demand activation expires. Obtain a permanent activation code or remove all temporary resources from partitions before the request expires. FRU List: SVCDOCS A7xx4750 A Capacity on Demand change has been detected.
Servicer Response: An incorrect activationcode has been detected. Resources associated with this activation code have been disabled. Enter a valid activation code. A7xx4741 Platform LIC detected an error
Servicer Response: The number of allowableattempts to enter a valid activation code has been exceeded. The system will continue to run, but a system IPL is required in order to retry entering a valid activation code. A7xx4742 Platform LIC detected an error
Servicer Response: UtilityCapacity on Demand resources have been activated. A7xx4788 System log entry only, no service action required
Servicer Response: A communications problemwith the service processor occurred. No Capacity on Demand changes can be made, but you can continue to run with the current Capacity on Demand resources. Look for errors with SRCs of the form B1xxxxxx or B7xx69xx in the Serviceable Event View. Work those errors first. If that does not correct the problem, re-IPL the system. If that does not correct the problem, contact your next level of support. FRU List: SVCDOCS A7xx4747 User intervention required
Servicer Response: The data obtained from the system is not what was expected. The IPL will continue. Should other errors occur, contact your next level of support. A7xx47C1 Capacity on Demand data mismatch
Servicer Response: The data obtainedfrom the system is not what was expected. The system will perform a slow IPL in order to obtain the correct data. If other errors occur, contact your next level of support. A7xx47CB Fast system IPL changed to slow system IPL
Servicer Response: One hour remains untilthe On/Off Capacity on Demand request expires. Permanently activate the temporary Capacity on Demand resources, enter a new On/Off Capacity on Demand request for the temporary resources, or remove all temporary resources from partitions before the request expires. FRU List: SVCDOCS A7xx4748 User intervention required
Servicer Response: The dataobtained from the system is not what was expected. The system will perform a slow IPL in order to obtain the correct data. If other errors occur, contact your next level of support. A7xx47CD Platform LIC detected an error
Servicer Response: The server detecteda not valid Capacity On Demand activation and terminated the system. The allocated resources for the system might exceed those that are available for use. FRU List: SVCDOCS A7xx47FF System log entry only, no service action required
Servicer Response: One hour remains until the Utility Capacity on Demand enablement expires. In order to reactivate temporary resources, a new Utility Capacity on Demand enablement code is required. FRU List: SVCDOCS
Servicer Response: The Capacity on Demand History Log has been written to the error log. No service action is required.
550
A7xx5120 A7xx5219
A7xx5120 Platform LIC detected an error A7xx5190 Operating System error
Servicer Response: Work with the FRUlist in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the system is not exhibiting problematic behavior, this error may safely be ignored. Otherwise, contact your next level of support. FRU List: NEXTLVL A7xx5121 Platform LIC failure
Servicer Response: Work with the FRU list inthe serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform detected a problem in an Operating System. Check for errors in the partition ID specified in word 4 of the SRC. If correcting those errors does not correct the problem, or if you find no errors, contact your next level of support. FRU List: SVCDOCS A7xx5191 Platform LIC detected an error
Servicer Response: Licensed Internal Code programexception occurred. Platform Licensed Internal Code detected a programming problem for which a platform dump may have been initiated. Send the system error log and the platform dump, if it occurred, to your next level of support. FRU List: NEXTLVL A7xx5122 Platform LIC detected an error
Servicer Response: A virtual adapter configuration error occurred. A partition tried to use a virtual adapter which is associated with another virtual adapter in a remote partition and virtual slot. However, either no virtual adapter is configured there, or the wrong kind of virtual adapter is configured there. The partition ID of the virtual adapter with the problem is in word 4 of the SRC (in hexadecimal format). The virtual slot number of the adapter with the incorrect configuration is the last four digits of word 6 of the SRC (in hexadecimal format). Use the Hardware Management Console (HMC) to verify or reconfigure the incorrect virtual adapter configuration. If the configuration is correct, continue with the next failing item in the list. FRU List: SVCDOCS LICCODE A7xx5209 Platform LIC detected an error
Servicer Response: Platform LicensedInternal Code detected that an IOP request failed. This error indicates a failure during a search for the load source. There may be a number of these failure prior to finding a good load source. This is normal. If a B2xx3110 error is logged, a B2xx3200 or B7005122 may be posted to the control panel. Work the B2xx3110 error in the Serviceable Event View. If the system IPL hangs at B2xx3200 or B7005122 and you cannot check the SRC history, perform the actions indicated for the B2xx3110 SRC. FRU List: SVCDOCS A7xx5123 Platform LIC detected an error
Servicer Response: System Licensed InternalCode detected an IOP timeout during IOP IPL. This may be caused by loose connections, improperly seated cards, media, or removeable media drive not in a ready state. Look for other errors. A7xx5219 Platform LIC detected an error
Servicer Response: A Licensed InternalCode program exception or data collection occurred. This may indicate an IOP programming problem or an IO Adapter boot problem. Look for other errors. If no other errors are present, Licensed Internal Code has recovered from any exception conditions, or this SRC has logged informational platform boto or hardware data.
Servicer Response: Information only,no service action required. Licensed Internal Code program exception occurred.
551
A7xx5300 A7xx6907
An IOP signalled to system Licensed Internal Code that it had entered a critical internal state. Licensed Internal Code automatically attempted to restart the IOP. A7xx5300 Platform LIC detected a failure while partitioning resources A7xx5600 Problem initializing, reading or using system VPD.
Servicer Response: Look for other hardware errors in the Serviceable Event View. If no other errors have been logged, contact your next level of support. A7xx5601 Platform LIC failure.
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Platform partitioning code encountered an error. This SRC represents a large number of possible problems, most of which involve the platform Licensed Internal Code (LIC). Work any error logs found in the Serviceable Event View. If this fails to correct the problem, or if there are no other errors, contact your next level of support. A7xx5301 User intervention required
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. There was a problem initializing, reading, or using system VPD. FRU List: NEXTLVL A7xx6900 PCI host bridge failure
Servicer Response: System detected a problemwith the Logical Partition (LPAR) Configuration. Use the Hardware Management Console to reconfigure the LPAR configuration. Check Hardware ManagementConsole (HMC) partition state. 1. If in Recovery state then use the HMC to perform Recovering partition data on a managed system. 2. Use HMC to activate partitions FRU List: SVCDOCS A7xx5400 A resource has been disabled due to hardware problems
Servicer Response: If you find a B7006981 SRClogged at about same time and listing parts from same enclosure as one of the FRUs here, then close this problem and work the B7006981 SRC. Work with the FRU list in the serviceable event view, if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. If the Serviceable Event View is not available, use the FRU List presented here for servicing this reference code. FRU List: PRIPCI MA_BRDG MABIP50 PIOCARD A7xx6906 System bus error
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform detected a problem with a processor. The processor is not functional. Look in the Serviceable Event View for a B1xx xxxx error that implicates a processor. If the Serviceable Event View contains no B1xx xxxx error, or if resolving the error fails to correct the problem, contact your next level of support. FRU List: SVCDOCS
Servicer Response: Work with the FRU list in the serviceableevent view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: SIIOADP A7xx6907 System bus error
Servicer Response: Work with the FRU list in the serviceableevent view if there is one, otherwise use the FRU list documented here to determine the parts to exchange.
552
A7xx6908 A7xx6972
FRU List: SIIOADP LICCODE A7xx6908 System bus error The partitionis still functional, but is operating in a degraded mode. Configuration informationmay be lost at the next IPL. In order to make more NVRAM available, delete one or more partitions. FRU List: SVCDOCS A7xx6952 System log entry only, no service action required. Platform LIC detected an error
Servicer Response: Work with the FRU list in the serviceableevent view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: SIIOADP MA_BRDG A7xx6909 System bus error
A7xx6965
Servicer Response: Unknown hardware detected.Look for other errors. A7xx6970 PCI host bridge failure
Servicer Response: Work with the FRU list in the serviceableevent view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: SIIOADP MA_BRDG LICCODE A7xx6944 Platform LIC detected an error
Servicer Response: If you find a B7006981 SRClogged at about same time and listing parts from the same enclosure as one of the FRUs here, then close this problem and work the B7006981 SRC. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: PRIPCI MA_BRDG MABIP50 PIOCARD A7xx6971 PCI secondary bus failure
Servicer Response: A system bus appearsto be empty. If the bus is not empty, a hardware or configuration problem might exist. Look for other errors. A7xx6950 Platform LIC detected an error
Servicer Response: A platform dump hasoccurred. The system has lost all the configured system settings (such as the HMC access and ASMI passwords, time of day, network configuration, hardware deconfiguration policies, etc.) that you might have set through user interfaces.Also, the system has lost the platform error logs and partition-related information, and the service processor is reset. Perform the recovery actions for the SVCPROC FRU but do not replace the service processor. The platform dump should be sent to your service provider. FRU List: SVCDOCS A7xx6951 Platform LIC detected an error
Servicer Response: Work with the FRU listin the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: MABIP51 PIOCARD MASBUS MA_BRDG A7xx6972 System bus error
Servicer Response: An error occurredbecause a partition needed more NVRAM than was available.
Servicer Response: Work with the FRU list in the serviceableevent view if there is one, otherwise use the FRU list documented here todetermine the parts to exchange. FRU List:
Chapter 10. Axxx Reference Codes
553
A7xx6973 A7xx6981
MA_BRDG PRIPCI A7xx6973 System bus error A7xx6979 System log entry only, no service action required.
Servicer Response: System log entry only, no service action required. A7xx697C Connection from service processor to system processor failed. Look for B15Cxxxx SRCs in the Serviceable Event View and resolve them.
Servicer Response: If you find a B7006981 SRC loggedon the same expansion unit as one of the FRUs here, then close this problem and work the B7006970 SRC. Use the unit value of the location codes to determine if the expansion unit is the same. Work with the FRU list in the serviceable event view, if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. If the first half of word 7 is not 0001, remove SVCPROC (the service processor) from the list of possible FRUs. FRU List: PIOCARD MA_BRDG SVCPROC PRIPCI MASBUS A7xx6974 IOP rejected the assignment of an IOA.
Servicer Response: If there are no B15CxxxxSRCs logged, then replace the failing items listed in the Serviceable Event View, if they are available. Otherwise, work with the failing items listed here. FRU List: SVCDOCS SVCPROC ANYPROC SYSBKPL A7xx6980 Network Interface Controller (NIC) resource failure
Servicer Response: If the serviceable event view contains a FRU list, work with those FRUs. Otherwise, exchange the failing items listed here. Note: A fiber optic cleaningkit may be required for optical HSL connections. A platform dump hasoccurred. Send the dump to your service provider. FRU List: SICNTRL LICCODE OPT_CLN A7xx6981 High Speed Link (HSL) I/O bridge failure
Servicer Response: An I/O Processor rejected the assignment of an I/O Adapter during the IPL of an i5/OS partition. If the partition IPLed successfully, this event is logged for information only. No service action is required. If the partition failed to IPL, replace the IOA. If that does not resolve the problem, replace the IOP that controls the IOA. The Direct Select Address (DSA) of the IOA is in word 7 of the SRC. In order to find the location of the IOA, see DSA translation to get the unit type in which the IOA is located. Then using the DSA and unit type, go to Card positions to find the location of the IOA. A7xx6978 System log entry only, no service action required.
Servicer Response: If you finda 1xxx SRC logged on the same expansion unit as one of the FRUs here, thenclose this problem and work the 1xxx SRC. Use the unit value of the locationcodes to determine if the expansion unit is the same. Work with theFRU list in the serviceable event view, if there is one. Otherwise, use the FRU list documented here to determine the parts to exchange. FRU List: SIIOADP
554
A7xx6982 A7xx6986
A7xx6982 High Speed Link (HSL) connection failure A7xx6984 System log entry only, no service action required
Servicer Response: Performthe RIOIP11 procedure. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Note: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SVCDOCS HSL_LNK OPT_CLN FRPORT TOPORT A7xx6983 An invalid High Speed Link (HSL) configuration was detected
Servicer Response: An HSL loop has switched to its alternate path. This is an informational SRC only. Word 7 of the SRC contains the loop number in the leftmost 4 digits. The loop number is in hexadecimal format. You must convert the hexadecimal loop number into decimal format to recognize the loop number. This SRC can be caused by a tower on the HSL loop powering off. This SRC may also appear in a Serviceable Event View you are using, with a B700 6982 or B700 6981 logged at approximately the same time. In that case the other SRC is reporting a failure and this SRC is reporting that the alternate RIO path is now being used. Service the other SRC if present. A7xx6985 High Speed Link (HSL) loop status message
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The four rightmost characters of word 4 in the reference code represent the Program Return Code (PRC), which describes the problem detected. The four leftmost digits of word 7 represent the loop number in hexadecimal format. Convert the loop number to decimal format before comparing it to loop numbers shown in serviceable event views and service tools. To determine the problem, find the PRC in the list below. Note: The FRU description in the serviceable event view may already contain a message that identifies the problem. v xxxx 0008 indicates the system serial number is not set. Set the serial number on the system unit. If the problem persists contact your next level of support. v xxxx 3201 indicates there are clustered systems on multiple HSL/RIO loops. You will need to ensure all clustered systems are on the same HSL/RIO loop. v xxxx 3217 indicates there is a model 5791, 5792, or 5794 IO drawer on a loop with clustered systems. This is not a supported configuration. This ends the procedure. FRU List: SVCDOCS
Servicer Response: This is a serviceable event only if this error is in a serviceable event view. If this is a serviceable event then perform RIOIP12. Otherwise if this is NOT a serviceable event then to determine what this SRC means use symbolic FRU SIRSTAT . Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. Note: A fiber optic cleaning kit may be required for optical HSL connections. FRU List: SVCDOCS HSL_LNK OPT_CLN FRPORT TOPORT A7xx6986 System bus error
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the Serviceable Event View is not available then use the failing item list presented here for servicing this reference code.
Chapter 10. Axxx Reference Codes
555
A7xx6987 A7xx69C3
FRU List: TWRCARD PWRCBL A7xx6987 High Speed Link (HSL) connection failure A7xx6994 Service processor failure
Servicer Response: Work with the FRU listin the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the ServiceableEvent View is not available then use the failing item list presented here for servicing this reference code. FRU List: SVCPROC A7xx6995 User intervention required
Servicer Response: Work withthe FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the Serviceable Event View is not available then use the failing item list presented here for servicing this reference code. FRU List: HSL_LNK OPT_CLN A7xx6990 Service processor failure
Servicer Response: The system is in the process of terminating. When all the partitions have terminated, an SRC indicating the exact cause will be shown on the operator panel. If the system does not terminate in a reasonable amount of time, one or more partitions may need to be terminated manually. If this is not possible, re-IPL the system and look for errors. If no errors are found, contact your next level of support. A7xx69C2 System log entry only, no service action required
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the Serviceable Event View is not available then use the failing item list presented here for servicing this reference code. FRU List: SVCPROC A7xx6991 Platform LIC failure
Servicer Response: Information only, no service action required. HSL OptiConnect normalconnection to another system or partition. HSL OptiConnect establishedconnection normally. The local system or partition is participating in HSL Opticonnect with other systems or partitions on the same HSL loop. A7xx69C3 Service processor failure System log entry only, no service action required
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: LICCODE A7xx6993
Servicer Response: Work with the FRU listin the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. If the ServiceableEvent View is not available then use the failing item list presented here for servicing this reference code. FRU List: SVCPROC LICCODE
Servicer Response: Information only, no service action required. Opticonnect normal remote disconnection from OptiConnect participation. HSL Opticonnect disconnected normally from a remote node. The local system or partition has stopped participating in HSL Opticonnect with the remote system or partition on the same HSL loop. Possible reasons include: v A remote system or partition went off line due to a normal power off or because HSL Opticonnect became disabled.
556
A7xx69C6 A7xx69C8
A7xx69C6 Platform LIC detected an error A7xx69C7 Platform LIC detected an error
Servicer Response: Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. The problem, which most likely originates with the remote system or partition, probably requires intervention at the remote system. Examine both the local and remote HSL OptiConnected systems or partitions for problems on this HSL loop. Possible reasons include: A fatal software or hardware error in the remote system or partition, or a power failure in the remote system. If a complete HSL loop did not exist before this error occurred, the cause of this error might be a failure or power down in an HSL component between the local system or partition and the remote system or partition. Check for a problem with the following: v An HSL cable v The HSL I/O bridge v Power in an expansion I/O tower or unit on this loop On the local system or partition, examine the Service Action Log (SAL) or serviceable event view. Look for HSL failures that occurred on the same HSL loop at approximately the same time as this error. Examine the remote system or partition for problems. If the remote system or partition is powered on and IPLd, examine the SAL or serviceable event view on the remote system or partition. Look for problems on the same HSL loop that occurred at approximately the same time as this error. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. When the remote system is IPLd, it will automatically reconnect with this system or partition. If you find no problems with either the local or the remote systems or partitions, collect all the Product Activity Log (PAL) information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. FRU List: SVCDOCS LICCODE
Servicer Response: Abnormal or unexpectedHSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. Licensed Internal Code will attempt to recover from the error. Intervention at the local or remote system or partition might be required. Possible causes include time out, hang, or hardware failure. The problem may be with the local system or partition or the remote system or partition. If a complete HSL loop did not exist before this error occurred, the cause of this error might be a failure or power down in an HSL component between the local system or partition and the remote system or partition. Check for SRCs with FRUs that indicate problems with the following: v HSL cables v The HSL I/O bridge v Power in an expansion I/O tower or unit on this loop On the local system or partition, examine the SAL or serviceable event view. Look for failures on the same loop or with the Network Interface Controller that occurred at approximately the same time as this error. Examine the remote system or partition for problems. Correct any HSL or NIC problems you find with the remote and local systems or partitions. If you find no problems with either the local or the remote systems or partitions, collect all the PAL information for this failure on both systems. Be sure to record all words in the SRC. Contact your next level of support. FRU List: SVCDOCS LICCODE A7xx69C8 Platform LIC detected an error
Servicer Response: Abnormal or unexpectedHSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an unexpected event or failure. All of the HSL OptiConnect connections on this loop will be in a failed state. Licensed Internal Code will attempt to recover from the error. Intervention at the local or remote system or partition might be required. Possible causes are: v Time out of a critical message v Licensed Internal Code code / table problem
Chapter 10. Axxx Reference Codes
557
A7xx69C9 A7xx69DA
v Network deadlock detected The problem may be with: v The local system or partition v The remote system or partition On the local system or partition, examine the SAL or serviceable event view. Look for HSL failures on the same HSL loop or with the Network Interface Controller that occurred at approximately the same time as this error. Examine the remote system or partition for problems. On the remote system or partition, examine the SAL or serviceable event view. Look for problems on the same HSL loop or with the Network Interface Controller that occurred at approximately the same time as this error. Correct any problems you find with the remote and local systems or partitions that happened at approximately the same time and involve HSL Opticonnect or HSL loop components or Network Interface Controllers. If there are no problems with the remote system or partition and there are no problems with the local system or partition then collect all the Product Activity Log information for this failure on all systems or partitions. Be sure to record all words in the SRCs. Contact your next level of support. FRU List: SVCDOCS LICCODE A7xx69C9 Platform LIC detected an error the serviceable event view. Look for HSL Opticonnect problems that occurred at approximately the same time as this error. Collect all the Product Activity Log information for this failure on all systems and partitions on this HSL loop. Be sure to record all words in the SRCs. Contact your next level of support. FRU List: SVCDOCS LICCODE A7xx69CF Platform LIC detected an error
Servicer Response: Abnormal or unexpected HSL OptiConnect disconnection from a remote system or partition. Licensed Internal Code internal error. All systems participating in HSL OptiConnect will be disconnected. You must re-IPL the system to recover. Before re-IPLing the system, start a platform dump. On the local system or partition, after getting the dump, examine the SAL or the serviceable event view. Look for HSL Opticonnect failures that occurred at approximately the same time as this error. Examine the remote systems or partitions for problems. On the remote systems or partitions, examine the SAL or the serviceable event view. Look for HSL Opticonnect problems that occurred at approximately the same time as this error. Collect all the PAL information for this failure on all systems and partitions on this HSL loop. Be sure to record all words in the SRCs. Contact your next level of support. FRU List: SVCDOCS LICCODE A7xx69D9 Host Ethernet Adapter (HEA) failure.
Servicer Response: Abnormal or unexpectedHSL OptiConnect disconnection from a remote system or partition. The local system or partition disconnected from a remote system or partition due to an failure in a Licensed Internal Code virtualized bus unit. Licensed Internal Code will attempt to recover from the error. Possible causes are: v Licensed Internal Code problem where the local bus unit is offline. v Licensed Internal Code problem where the remote bus unit is offline. On the local system or partition, examine the SAL or the serviceable event view. Look for HSL Opticonnect failures that occurred at approximately the same time as this error. Examine the remote system or partition for problems. On the remote system or partition, examine the SAL or
Servicer Response: Firmware detected a hardware failure in the Host Ethernet Adapter (HEA). FRU List: HEA A7xx69DA System log entry only, no service action required.
558
A7xx69DB A7xx69EC
A7xx69DB Platform LIC failure. A7xx69E6 System log entry only, no service action required
Servicer Response: A Platform Licensed Internal Code error occurred. The system will continue to run this Host Ethernet Adapter (HEA) disabled. Perform a platform dump and then IPL the system to recover the HEA. Send the platform dump to your next level of support. FRU List: SVCDOCS A7xx69E1 Host Channel Adapter
Servicer Response: The cable connection to the InfiniBand switch is broken. Verify that the cable is connected and the switch is powered on. After repairing the problem, verify that the connection has been restored by using the IBM Network Manager. Does not require service. A7xx69E7 System log entry only, no service action required
Servicer Response: The InfiniBand Host Channel Adapter has failed. FRU List: HCA A7xx69E2 Platform LIC failure
Servicer Response: The cable connection to the InfiniBand switch has been restored. No service action required. A7xx69E9 System log entry only, no service action required
Servicer Response: An InfiniBand platform licensed internal code error occurred. The system will continue to run with this Host Channel Adapter disabled. Perform a platform dump prior to the IPL on the system. An IPL is required to recover the Host Channel Adapter. FRU List: LICCODE A7xx69E3 System log entry only, no service action required
Servicer Response: Initial communication has occurred with the Subnet Manager. No service action required. The CEC and switch firmware are now communicating. A7xx69EA System log entry only, no service action required
Servicer Response: Part of the HCA chip failed but was not terminating. When thresholded, these errors will result in a B70069E1. A7xx69E4 An invalid High Speed Link (HSL) configuration was detected
Servicer Response: Reported when the logical switch receives a setPortInfo for the switch management port that sets a new SM LID. This indicates the point where DMA can reportchanges in switch port states to SM via a TRAP and also that SM has received and accepted out responses to the initial gets. This proves that there is 2-way communication. Note that this will also tell us when a subnet merge has occurred and a new SM has issued a setPortInfo with an SMLID that differs from the previous one. No service action required. A7xx69EB User intervention required
Servicer Response: An error was detected in the InfiniBand fabric. Have the customer check for problems reported at the IBM Network Manager. This includes cases such as path migration, etc. FRU List: SVCDOCS A7xx69E5 System log entry only, no service action required
Servicer Response: An InfiniBand configuration error was detected by the HCA. Verify that the InfiniBand configuration is correct at the HCA. The Port 1 and 2 configurations conflict. FRU List: SVCDOCS A7xx69EC User intervention required
Servicer Response: An InfiniBand communications error occurred. Unrecognized command from Subnet Manager. Does not require service.
Servicer Response: An InfiniBand adapter in the server does not support connections to I/O enclosures. Upgrade the adapter at the location given in the serviceable event view to a new version. Contact support for assistance. FRU List:
Chapter 10. Axxx Reference Codes
559
A7xx69ED A7xxF10B
SVCDOCS A7xx69ED RIO 12X link is not operating at optimal bandwidth. A7xxF103 Platform LIC failure
Servicer Response: An RIO 12X cable connection initialized to a lower signal frequency. The link is operational but operating at a bandwidth below its rated capacity. This may lead to degraded I/O throughput. Perform the RIOIP56 procedure. Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. FRU List: SVCDOCS HSL_IB FRPORT TOPORT A7xx69EE I/O unit backplane is not operating at optimal bandwidth.
Servicer Response: Work with the FRU list in theserviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform LIC detected an internal problem. Collect all the SRC words and the platform system dump, then contact your next level of support. FRU List: LICCODE A7xxF104 Operating System error
Servicer Response: Platform Licensed InternalCode terminated a partition. If SRC word 3 is 0007, then a user may have initiated a function 22 prior to the operating system completing the IPL. If a function 22 was not performed, or if SRC word 3 is not 0007, look for other serviceable errors which occurred at same time frame. FRU List: SVCDOCS A7xxF105 Platform LIC detected an error
Servicer Response: Replace the I/O unit backplane at your next scheduled maintenance. FRU List: TWRBKPL A7xxBAD1 Platform firmware detected an error
Servicer Response: Work with the FRUlist in the serviceable event view if there is one, otherwise use the FRU list documented here to determine the parts to exchange. The platform LIC detected an internal problem. Collect all the SRC words and the platform system dump, then contact your next level of support. FRU List: NEXTLVL A7xxF10A Platform LIC detected an error
Servicer Response: Platform firmwaredetected unexpected or not valid data returned from non-platform firmware. Contact your next level of support. FRU List: NEXTLVL A7xxC2AC System log entry only, no service action required
Servicer Response: The Capacity on Demand License acceptance has completed. No corrective action is required. FRU List: SVCDOCS
Servicer Response: Look for errors withSRCs of the form B1xx xxxx in the Serviceable Event View. Work those errors first. If that does not correct the problem, collect all the SRC words and the platform system dump, then contact your next level of support. FRU List: SVCDOCS A7xxF10B A resource has been disabled due to hardware problems
Servicer Response: Work with the FRU list in the serviceable event view if there is one, otherwise use the FRU list documented
560
A7xxF120 A90036A0
here to determine the parts to exchange. The platform detected a problem with a processor. The processor is not functional. Look in the Serviceable Event View for a B1xx xxxx error that implicates a processor. If the Serviceable Event View contains no B1xx xxxx error, or if resolving the error fails to correct the problem, contact your next level of support. FRU List: ANYPROC A7xxF120 Platform firmware detected an error
Servicer Response: The platform is unable to support the requested architecture options requested by the operating system via ibm, client-architecture-support interface.
Servicer Response:: Perform the following action: 1. If the IPL completed normally, does the console have a signon? Note: If the console did not vary on, see Recovering when the console does not show a sign-on display or a menu with a command line. 2. If the system completed the IPL, check the QSYSARB job log for a message, and follow the corrective actions indicated. To view the QSYSARB job log: v Use the Work with Active Jobs (WRKACTJOB) command, and then type 5 (Work with) next to the QSYSARB job. v Select Option 10 (Display jobs) to view the job log. You need *QSECOFR user class, or *ALLOBJ and *JOBCTL special authority to view the job log. 3. If the problem persists, contact your next level of support or your hardware service provider. A9003610 The system job tables are full for i5/OS.
Servicer Response:: Perform the following actions to recover: v Shut down the system and perform an IPL. v If the problem persists, contact your next level of support.
Servicer Response::
561
AA00E158 AA06000C
AA00E158 Waiting for virtual terminal (VTERM) to be opened on the HMC. v If you do not find a BAxx xxxx error code, see Problems With Loading and Starting the Operating System (for AIX and Linux) to resolve the boot problem. FRU List: FWFLASH AA00E1B0 Waiting for the user to select language and keyboard.
Servicer Response:: 1. Open a virtual terminal window (vterm) on the HMC. 2. Close the existing terminal window (vterm) and reopen. 3. If theres no need to access the SMS menus, go to the ASMI, and do the following: a. Select Power/Restart Control, then Power On/Off System. b. Select Continue to operating system under the option labeled AIX/Linux partition mode boot. AA00E159 Waiting for serial connection to the service processor to be established
Servicer Response:: Select the language and keyboard. AA00E1B1 Waiting for the user to accept or decline the license agreement.
Servicer Response:: Accept or decline the license agreement. AA00E1F3 Admin access password prompt
Servicer Response:: Check the serial connection to the service processor. Correct any problems that are found. AA00E175 The I/O configuration exceeds the recommended size. Some operating systems might crash when using this configuration.
Servicer Response:: On the firmware console, enter the pasword for the admin user of the ASMI. FRU List: FWPWD AA060007 A keyboard was not found
Servicer Response:: Increase the logical memory block (LMB) size to 256 MB and reboot the managed system. Note: Contact the next level of support if the LMB size is already 256 MB. FRU List: FWFLASH AA00E1A8 FRU List: FWFLASH AA00E1A9 The system is booting to the SMS menus The system is booting to the open firmware prompt
Servicer Response:: Ensure that a keyboard is attached to a USB port assigned to the partition. AA06000B The system or partition was not able to find an operating system on any of the devices in the boot list.
Servicer Response:: Modify the boot list using the SMS menus so that it includes devices that are known to have a good copy of the operating system and retry the boot. If you are still unable to boot an operating system, go to Problems With Loading and Starting the Operating System. AA06000C The media specified in a device in the bootlist was not bootable
Servicer Response:: Note: If the system or partition returned to the SMS menus (as indicated by this progress code) after a boot attempt failed, use the ASMI menus to look at the progress code history. v Look for a BAxx xxxx reference (error) code, which might indicate why the boot attempt failed. If you find a BAxx xxxx error code, see (BAxx) Partition Firmware Reference (Error) Codes) to find the code, then follow the actions indicated to resolve the boot problem.
Servicer Response:: Replace the media in the device with known-good media, or modify the boot list to boot from another bootable device. If you are still unable to boot an operating system, go to Problems With Loading and Starting the Operating System.
562
AA06000D AA170211
AA06000D The media in the device in the bootlist not found under the I/O adapter specified by the boot list. 1. Check the error log for other SRCs that were logged around the time of this SRC. If other SRCs are found, resolve those, then reboot the system. If the problem is not resolved, go to the next step. 2. Check for system firmware updates and apply if available. 3. Contact your next level of support. AA100002 A bad return code was received when the LP event acknowledgement was received from the hypervisor.
Servicer Response:: Verify that the medium (CD-ROM, for example) from which you are trying to boot is bootable, or try another medium. If you are still unable to boot an operating system or diagnostic CD-ROM, go to Problems With Loading and Starting the Operating System. AA06000E The adapter specified in the boot list is not present or not functioning.
Servicer Response:: If AIX is being booted, and can be booted from another device, do so, then run online AIX diagnostics against the failing adapter. If AIX cannot be booted from another device, boot standalone AIX diagnostics from CD-ROM or a NIM server and run diagnostics against the device. If Linux is being booted, boot standalone AIX diagnostics from CD-ROM or a NIM server and run diagnostics against the device. AA060010 The FAT filesystem on the bootdisk is configured in a way that may cause a boot failure.
Servicer Response:: Reboot the system. If the problem persists, do the following: 1. Check the error log for other SRCs that were logged around the time of this SRC. If other SRCs are found, resolve those, then reboot the system. If the problem is not resolved, go to the next step. 2. Check for system firmware updates and apply if available. 3. Contact your next level of support. AA130013 Bootable media is missing from a USB-attached CD-ROM.
Servicer Response:: Increase the FAT partition size by 10% to keep the number of data clusters fewer than 4080. AA060011 The firmware did not find the operating system image and is was unable to detect at least one hard disk in the boot list. Firmware is now retrying the entries in the boot list. This often occurs when the boot disk enclosure is not yet fully initialized or if the boot disk belongs to a server partition.
Servicer Response:: Put a bootable CD in the USB CD-ROM drive and retry the boot operation. AA130014 The media in the USB CD-ROM drive has been changed.
Servicer Response:: 1. Retry the operation. 2. Check for system firmware updates; apply if available, then retry the operation. AA170210 Setenv/$setenv parameter error - the name contains a null character.
User response: This error might occur before the initialization of an enclosure that contains the boot disk is complete or when the boot disk belongs to another partition. If this problem persists, do the following: 1. Verify that the boot disk belongs to the partition that is being booted. 2. Verify that the boot list in the SMS menus is correct. AA100001 The hypervisor failed to send an LP event to the partition firmware.
Servicer Response:: Refer to the NVRAM problems section below FRU List: FWFLASH AA170211 Setenv/$Setenv parameter error - value contains a null character
Servicer Response:: Refer to the NVRAM problems section below. FRU List: FWFLASH
Servicer Response:: Reboot the system. If the problem persists, do the following:
563
AA190001 AA260005
AA190001 The server firmware function to get and set the time-of-day reported an error.
Servicer Response:: 1. Use the operating system utility to set the system clock. 2. If the problem persists, check for server firmware updates and apply if available. AA260001 The firmware is waiting for someone to enter the machine type, model, and serial number.
Servicer Response:: At the firmware prompt, enter the machine type, model, and serial number of the system. AA260002 The system is waiting for the serial number to be entered.
Servicer Response: Enter the serial number of the system at the prompt AA260003 The system is waiting for the system unique ID number to be entered.
Servicer Response: Enter the system unique ID number at the prompt. AA260004 The system is waiting for the worldwide port number to be entered.
Servicer Response: Enter the worldwide port number at the prompt. AA260005 The system is waiting for the brand number to be entered.
564
565
566
Notices
This information was developed for products and services offered in the U.S.A. The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturers representative for information on the products and services currently available in your area. Any reference to the manufacturers product, program, or service is not intended to state or imply that only that product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any intellectual property right of the manufacturer may be used instead. However, it is the users responsibility to evaluate and verify the operation of any product, program, or service. The manufacturer may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to the manufacturer. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: THIS INFORMATION IS PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. The manufacturer may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to Web sites not owned by the manufacturer are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this product and use of those Web sites is at your own risk. The manufacturer may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. Information concerning products not produced by this manufacturer was obtained from the suppliers of those products, their published announcements or other publicly available sources. This manufacturer has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to products not produced by this manufacturer. Questions on the capabilities of products not produced by this manufacturer should be addressed to the suppliers of those products. All statements regarding the manufacturers future direction or intent are subject to change or withdrawal without notice, and represent goals and objectives only.
567
The manufacturers prices shown are the manufacturers suggested retail prices, are current and are subject to change without notice. Dealer prices may vary. This information is for planning purposes only. The information herein is subject to change before the products described become available. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. If you are viewing this information in softcopy, the photographs and color illustrations may not appear. The drawings and specifications contained herein shall not be reproduced in whole or in part without the written permission of the manufacturer. The manufacturer has prepared this information for use with the specific machines indicated. The manufacturer makes no representations that it is suitable for any other purpose. The manufacturers computer systems contain mechanisms designed to reduce the possibility of undetected data corruption or loss. This risk, however, cannot be eliminated. Users who experience unplanned outages, system failures, power fluctuations or outages, or component failures must verify the accuracy of operations performed and data saved or transmitted by the system at or near the time of the outage or failure. In addition, users must establish procedures to ensure that there is independent data verification before relying on such data in sensitive or critical operations. Users should periodically check the manufacturers support websites for updated information and fixes applicable to the system and related software.
Trademarks
The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both: AIX eServer IBM IBM (logo) iSeries i5/OS OS/400 INFINIBAND, InfiniBand Trade Association, and the INFINIBAND design marks are trademarks and/or service marks of the INFINIBAND Trade Association. Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both. Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Other company, product or service names may be trademarks or service marks of others.
568
Notices
569
The following is a summary of the VCCI Japanese statement in the box above. This product is a Class A Information Technology Equipment and conforms to the standards set by the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
Declaration: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may need to perform practical action.
The following is a summary of the EMI Taiwan statement above. Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user will be required to take adequate measures. IBM Taiwan Contact Information:
570
Please note that this equipment has obtained EMC registration for commercial use. In the event that it has been mistakenly sold or purchased, please exchange it for equipment certified for home use.
571
Generelle Informationen: Das Gert erfllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
572
Printed in USA
SA76-0089-04