1 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Codeword variants. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.6 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Alternate routing on error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1.1 Usage of the feature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1.2 Main goals for the alternate routing destination numbers in
respect to OOS scenario . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.1.3 Usage of alternate routing destination numbers . . . . . . . . . . . . . . . . . . . . . . 17
2.1.4 Subscriber number supplementation (parameter EXTNO) . . . . . . . . . . . . . . 19
2.2 User interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1 Examples for usage the alternate routing on error in different
OOS scenarios. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1.1 Called subscribers (A,B,C,D,E of one source group), are not reachable,
because of device/board errors.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.2.1.2 Called subscriber is not reachable, because deactivated via AMO with
additional request for alternate routing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
2.2.1.3 Called HFA IP phones (A,B) are not reachable, because of IP errors,
they moved their logon location from HiPath 4000 to HiPath 3000.. . . . . . . . 30
2.2.1.4 Called subscribers (A,B) in its APs are in an APE situation to AP of the
calling device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
2.3 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.3.1 Additional control mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
2.3.2 General plausibility information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
1
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features
2
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
The dongle or the SIM card and the codeword "tell" the system which feature packages and
quantities were purchased by the customer. When the system is configured, a special plausi-
bility check is used to ensure that the configuration data corresponds to the purchased features
and quantities.
3
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
PNE
Voice com-
Entry Agent
pression IP
CODEWORD
In HiPath 4000 V2.0 and later, the CODEWRD will feature four variants:
1. Normal mode:
This is the approved operating mode as implemented in HiPath 1.0. In normal mode, a
codeword and licenses are requested for all relevant licenses in the database.
2. Trial mode:
This feature introduces a time-limited trial mode. When you activate trial mode, you can
skip the license restrictions that are temporarily displayed. During this time, the AMOs work
as if unrestricted licenses were available except that an advisory message is sent to the
users if license restriction violations occur.
3. Emergency mode:
The system activates the Emergency mode, in case of special situations.
Special situations are:
Validity of the Codeword is expired;
Dongle resp. SIM card is missing;
Codeword is missing;
Dongle resp. SIM card does not match to Codeword;
4
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
● In a network the network codeword from the Hipath 4000 Manager (LMT) is used.
The original Codeword must be added previously in the system.
The Network codeword then overwites the Codeword on a daily basis. If this does not hap-
pen then a 60 day test mode begins.
● The 30 Day Service-Dongle will no longer be given in Hipath4000 V2.0.
● The Type 2 codeword will only be given in special cases.(applied for as an extra).
● The creation date is coded in the Codeword and is stored in the database, when the Code-
word is added in the system. The try to add an older Codeword is blocked in this way.
5
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
6
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
7
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
8
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
● Further information on the AMO CODEW can be found in the AMO description in the
service manual.
DISPLAY-CODEW;
H500: AMO CODEW STARDED
CODEWORD: AFTKSB3CJYN4LKZN7GNWZH8TXH63M29A5GA2L2JN261LGKEA8CPHLZV5UGKHVPHP
XGRZDWDF83BG6BLE2U6LSP8GYS8VY5NADW88BUAE6RA58HXMD2N99TJSC9
VERSION : H205
SERIAL NUMBER: 7
HARDWARE ID : C6EB8F3B
ENTRY DATE : 22.02.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 3706
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 976 | 913 | 63 | |
9
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
| CORDLESS E | 0 | 0 | 0 | |
| PNE | 0 | 0 | 0 | |
| HIPATH PROCENTER ENTRY AGENT | 0 | 0 | 0 | |
| SIGNALING SURVIVABILITY | 0 | 0 | 0 | |
| CC-AP FOR AP EMERGENCY | 0 | 0 | 0 | |
+---------------------------------------------+-------+-------+-------+-------+
H07: THE TEST MODE IS AVAILABLE (ANOTHER) 2 TIMES.
DISPLAY-CODEW;
DISPLAY-CODEW;
H500: AMO CODEW STARTED
CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 07.01.2004
VALID UNTIL : 17.12.2005
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
10
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
| COMSCENDO | | 110 | | |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: CURRENT CODEWORD IS A TYPE 2 CODEWORD.
Trial mode
The purchased quantity can be temporarily expanded with trial mode.
Trial mode is activated with CHANGE-CODEW. Utilization is not unlimited (maximum number
specified in codeword, generally 2) and has a maximum utilization time (generally 30 days).
SWU administration is not disabled even if license violation is shown in trial mode ("!!!!!" in the
"FREE" column). A mark that can be displaced with the AMO SDSU is applied to elements that
exceed the license limit (stations, trunks, etc.). The number of units marked is also displayed in
the AMO CODEW.
Trial mode is automatically terminated if not manually deactivated within the maximum time lim-
it. When this happens, marked elements are disabled for security reasons and can only be en-
abled if an appropriate codeword is set up.
No elements are marked or disabled for the features HIPATH PROCENTER ENTRY AGENT
and HIPATH AP VOICE COMPRESSION IP. However, when trial mode ends, no agents above
and beyond the license limits can log on and compressed connections cannot be set up.
Trial mode does not apply to the features HIPATH AP REMOTE SURVIVABILITY and CC-AP
FOR AP EMERGENCY. The codeword’s license limit cannot be exceeded here.
● Activate trial mode:
CHANGE-CODEW:TRIAL=YES;
....(activated after consultation)
11
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 18.12.2003
VALID UNTIL : 17.12.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 110 | 110 | !!!!! | 1 |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: THE TEST MODE IS AVAILABLE (ANOTHER) ONCE.
12
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Protection of Software Features Siemens
DISPLAY-SDSU:STATUS=LICMARK,TYPE=PEN,LEVEL=PER3;
DISPLAY-SDSU:STATUS=LICBLOCK,TYPE=PEN,LEVEL=PER3;
....(specifies the stations disabled on account of license violation
when the trial mode expired.)
13
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Protection of Software Features
14
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
15
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
● Manual deactivated (by AMO) with activated authorization for alternate routing
If subscribers are deactivated manualy by AMO command, alternate routing will only be
performed, if the subscribers are authorized for requesting alternate routing when called
after a manual deactivation.
The goal is identical as for device/ board errors.
● APE situation between APs of calling device and called subscriber/ personal atten-
dant.
In case of an APE situation between APs of calling device and called subscriber/
personal_attendant, the involved APs act as single switches.
The goal is, to reach the called subscriber in its AP via public trunk access. As a precondi-
tion, a public trunk access has to be administered between the related APs with routing
elements without internal rerouting possibilities.
Attention:
7 Routing elements, that are defined as with "internal rerouting", will not be
used for alternate routing on error in general.
16
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
17
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
Depending of the OOS scenario (1 --> 4) the alternate routing destination numbers will be
checked for usage in the following hierarchical manner:
● OOS because device/board error
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS because manual deactivated with activated authorization for alternate routing
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS of logged off HFA IP phones with activated authorization for move logon
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
● OOS because of APE situation between APs of called subscriber and calling device
– subscriber individual alternate routing destination number for APE
– source group related alternate routing destination number for APE
If the called subscriber is not a HFA IP phone with the activated authorization for move
logon, 2 additional attempts will be done
– subscriber individual alternate routing destination number for OOS
– source group related alternate routing destination number for OOS
18
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
19
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
Example 1:
Exit Code = 0
Outgoing public trunk access = 0004989
Number (subscriber_A) = 54321
Administered source group related alternate routing number = 0004989-722
EXTNO = 5 --> supplementation done / result = 0004989-722-54321
EXTNO = 6 --> supplementation done / result = 0004989-722-54321
EXTNO = 4 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / the number 0004989722 do not
lead to a valid destination, but neither by AMO nor at time
of usage, this can be verified.
20
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
Example 2:
Paging access code = #77
Number (subscriber_A) = 54321
Administered source group related alternate routing number = #77
Search length = 3
EXTNO = 3 --> supplementation done / result = #77-543
EXTNO = 4 --> supplementation done / result = #77-543
EXTNO = 2 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / invalid
Example 3:
Paging access code = #77
Number (subscriber_A) = 54321
Administered source group related alternate routing number = #77
Search length = 0
Source group related alternate routing number = #77
EXTNO = 5 --> supplementation done / result = #77-54321
EXTNO = 6 --> supplementation done / result = #77-54321
EXTNO = 2 --> supplementation not possible
EXTNO = 0 --> supplementation not requested / invalid
21
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
It may be possible, that the HiPath 3000 works with a different number scheme than the
HiPath 4000.
If the HFA IP phone extension numbers are identically in both switches, you have to set the
parameter EXTNO to the identical extension number length of the HFA IP phones.
If the HFA IP phone extension numbers in the HiPath 3000 are smaller than in the HiPath
4000 (see example 4), you have to set the parameter EXTNO to the smaller HFA IP phone
extension number length. in HiPath 3000. The later performed supplementation then will
cut the HFA IP phone extension numbers from left hand side on.
If the HFA IP phone extension numbers in the HiPath 3000 are bigger than in the HiPath
4000 (see example 5), you have to set the parameter EXTNO to the length of the HFA IP
phone extension number in the HiPath 4000. As the extension numbers in HiPath 3000
starts with an additional digit (9), you must add this as a prefix to the source group related
alternate routing number.
Example 4:
Outgoing public trunk access = 0004989,
Incoming trunk access for HiPath 3000 = 865
Number (HFA IP phone_A in HiPath 4000) = 54321
Number (HFA IP phone_A in HiPath 3000) = 4321
Administered source group related alternate routing number = 0004989-865
EXTNO = 4 --> supplementation done / result = 0004989-865-4321
EXTNO = 5 --> supplementation done / result = 0004989-865-54321
In HiPath 3000 -, the correct HFA IP phone can not be reached.
No kind of syntax check can avoid this malfunction.
EXTNO = 3 --> supplementation done / result = 000498986-5321
In HiPath 3000 -, the correct subscriber can not be reached.
No kind of syntax check can avoid this malfunction.
EXTNO = 0 --> supplementation is not requested / invalid
22
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
Example 5:
Outgoing public trunk access = 0004989,
Incoming trunk access for HiPath 3000 = 865
Number (HFA IP phone_A in HiPath 4000) = 54321
Number (HFA IP phone in HiPath 3000) = 9-54321
Administered source group related alternate routing number = 0004989-865-9
23
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
2.2.1.1 Called subscribers (A,B,C,D,E of one source group), are not reachable,
because of device/board errors.
● What are the main goals?
Calling a subscriber specific individual alternate routing destination number (mobile phone
number)
Calling a general destination like voicemail or attendant.
● What is possible?
The alternate routing number can be designed to reach any other destination.
If the alternate routing destination number leads to a outgoing trunk access, only those rou-
te elements will be used for alternate routing, that are defined as with "no internal rerou-
ting".
24
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
7100 017nnn..nnn
ISDN
STN-A
OOS-NO =
0017nnn..nnn
STN-F
7101 NO = 4444444
Paging
STN-B NO = #17
OOS-NO =
00303864444444
ATND = 99
STN-C
STN-D
Source -Grp = 3
ALT-NO = 99
STN-G
NO = 5555
ATNDIND=
7199 Source -Group = 2
ALT-NO = #17
ATNDIND with EXTNO
OOS-NO = 5555
25
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
● AMO usage
– Calls to subscriber_A should be alternate routed to a mobile phone number
017nn...nn. Calls to subscriber_B should be alternate routed to a national public num-
ber subscriber_F
For routing type = OOS, you must define a subscriber individual alternating routing desti-
nation number for subscriber_A:
CHANGE-SDAT:STNO=7100,TYPE=DATA1,STNOOOS=<0017nnn...nnn)
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for subscriber_B:
CHANGE-SDAT:STNO=7101,TYPE=DATA1,STNOOOS=00303684444444
If the Redirecting number has to be send to the Carrier, the COT parameter R261 is to be
set on the trunk:
CHANGE-COT:COTNO=xxx,COTTYPE=COTADD,PAR=R261;
– Calls to subscriber_C and subscriber_D of the related source group 3, should be al-
ternate routed to the attendant.
For the related source group, you can define a source group related complete alternate
routing destination number for routing type = OOS:
ADD-APRT:TYPE=ALTERR,SCRGRP=3,ALRTYPE=OOS,ALTRTNR=99;
– Calls to all subscribers of source group = 2 should be alternate routed to Paging sys-
tem.
It will be assumed, that the Paging system works with LENGTH_SEARCH_NO = 0.
For routing type = OOS, you must define a source group related incomplete alternate rout-
ing destination number for that source group 2, the called subscribers are members of.
As for every subscriber an individual search number is requested, the alternate routing
destination number must be a incomplete number containing only the access code for
PSM.
You must set the number of the supplemented digits (parameter EXTNO) equal the number
length of subscribers extension number.
ADD-APRT:TYPE=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=#17,EXTNO=4;
If the Paging system works with length search no = x (1-6), you must administer the param-
eter
EXTNO = <length_search_no>.
26
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
– Private calls for the attendant console 7199 should be alternate routed to to
subscriber_G.
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for ATNDIND=7199:
CHANGE-ACSU:ATNDNO=7199,STNOOOS=5555;
Caution: If you change the source group of a subscriber with AMO SDAT, the administered
source group related alternate routing informations may not be valid anymore for this sub-
scriber!
If the public network (Carrier) is checking the calling number, the new COT pa-
rameter R261 must be set on the CO / TIE trunk, to send the Redirecting num-
ber.
If an analoge Phonemail is used for OOS, the number is checked in AMO ZIEL.
If the number is a VMX (Type in AMO ZIEL) destination, the Redirecting num-
ber is send.
For using a digital Voicemail / Xpression the destination number of the Voice-
mail/Xpression has to be set in AMO ZIEL -> VMX, too. If the COT parameter
R261 is used on the Tie trunks instead of th VMX entry, there could be prob-
lems in a network.
2.2.1.2 Called subscriber is not reachable, because deactivated via AMO with
additional request for alternate routing
● What are the main goals?
Calling a subscriber specific individual alternate routing destination number (mobile phone
number)
Calling a general destination like analoge Phonemail, digital Voicemail/Xpression or atten-
dant.
● What is possible?
The alternate routing number can be designed to reach any other destination.
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".
27
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
analoge Phonemail
90417
7100
STN-A ATND= 99
OOS-NO=90147
7150 S2
Xpression
STN-B
90500
OOS-NO=90500
STN-C
7120
Deactivate-DSSU: STN-A
STN-D Deactivate-DSSU: STN-B
Deactivate-DSSU: STN-C
7121 Deactivate-DSSU: STN-C
Deactivate-BSSU:............
Source -Grp = 3 Deactivate-USSU:.............
ALT-NO = 99
● AMO usage
– Calls to a deactivated subscriber-A and subscriber_B should be alternate routed to the
analoge Phonemail respec. to the Xpression.
For routing type = OOS, you must define a subscriber individual alternate routing destina-
tion number for the subscriber_A and subscriber_B:
CHANGE-SDAT: STNO=7100,TYPE=DATA1,STNOOOS=90147;
CHANGE-SDAT: STNO=7150,TYPE=DATA1,STNOOOS=90500;
28
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
You must set a request for alternate routing, before deactivating the subscriber-A and
subscriber_B with AMO e.g. DSSU:
CHANGE-SDAT:STNO=7100,TYPE=DATA1,AMOALTRT=YES;
CHANGE-SDAT:STNO=7150,TYPE=DATA1,AMOALTRT=YES;
To send the Redirecting number to the Xpression and the Phonemail, the Xpression/Pho-
nemail number is to be set in AMO ZIEL:
ADD-ZIEL:TYPE=EVMACC,.....,MRCD=90500;
ADD-ZIEL:TYPE=EVMACC,.....,MRCD=90147;
– Calls to subscriber_C and subscriber_D of the related source group 3, should be al-
ternate routed to the attendant.
For the related source group, you can define a source group related complete alternate
routing destination number for routing type = OOS:
ADD-APRT:TYPE=ALTERR,SCRGRP=3,ALRTYPE=OOS,ALTRTNR=99;
You must set a request for alternate routing, before deactivating the subscriber_C and
subscriber_D with AMO e.g. DSSU:
CHANGE-SDAT:STNO=7120&&7121,TYPE=DATA1,AMOALTRT=YES;
If you set this request and no kind of alternate routing destination number was
administered before, the AMO SDAT will print out a hint-message.
If the public network (Carrier) is checking the calling number, the new COT pa-
rameter R261 must be set on the CO trunk, to send the Redirecting number.
If an analoge Phonemail is used for OOS, the number is checked in AMO ZIEL.
If the number is a VMX (Type in AMO ZIEL) destination, the Redirecting num-
ber is send.
For using a digital Voicemail / Xpression the destination number of the Voice-
mail/Xpression has to be set in AMO ZIEL -> VMX, too. If the COT parameter
R261 is used on the Tie trunks instead of th VMX entry, there could be prob-
lems in a network.
29
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
2.2.1.3 Called HFA IP phones (A,B) are not reachable, because of IP errors,
they moved their logon location from HiPath 4000 to HiPath 3000.
Scenario 1
CO Number:
+49-89-568
HiPath 4000 IP: 1.30.11.180 ISDN
STMI H G1 5 0 0
Moving by fault HiPath 3
000
IP: 1.40.41.180
IP
54711 Network
MOVING
4711
SUB-A
OOS-No =
00049895684711
54712
4712
MOVING
TLN-B
OOS-No =
00049895684712
or
Source-Grp = 2
ALT-No = 0004989568
with Extno= 4
30
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
● Device configuration:
● What is possible?
The alternate routing destination number can be designed as outgoing public trunk access
or outgoing tie trunk access followed by incoming trunk access to reach the Hipath 3000.
The alternate routing destination number can be designed as a subscriber individual alter-
nate routing number or as an incomplete source group related alternate routing number
(with supplementation request).
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".
31
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
● AMO usage
– Calls to not reachable HFA IP phones, that have moved their logon location from
HiPath 4000 to HiPath 3000, should be routed to the new logon location via public net-
work. In HiPath 3000, the HFA IP phones have a different number scheme than in
HiPath 4000.
You must authorize those HFA IP phones, that can move their logon location from
HPath 4000 to HiPath 300:
CHANGE-SDAT:STNO=54711,TYPE=DATA1,MVHFAIP=YES;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,MVHFAIP=YES;
You must set the gateway_IP address(es) for the source group(s), the HFA IP phones are
members of. This is necessary to avoid loops within the HiPath 4000 and HiPath 3000 net-
work.
For example, it could be possible, that a HFA IP phone is already logged off in HiPath 4000
and not yet logged on in HiPath 3000. In this case, every switch tries to perform an alter-
nate routing to the other switch (ping/pong).
ADD-APRT:TYPE= ALTERR,SRCGRP=2,ALRTYPE=OOS,GWIPADR=1.30.11.180;
For type= OOS, you must define either subscriber individual alternate routing destination
numbers for every HFA IP phone (A,B) or a source group related incomplete alternate rout-
ing destination number for the source group(s), the HFA IP phones are members of.
A incomplete alternate routing destination number will be supplemented at time of usage
with the extension number of the called HFA IP phone and with the administered length
(parameter EXTNO). This makes it possible to reach individual subscribers in other switch-
es.
If you want to use only subscriber individual alternate routing destination numbers, you
have to administer a subscriber individual alternate number for both HFA IP phones with
outgoing trunk access to public network (004989), with incoming trunk access to reach the
HiPath 3000 (568) and the shortened part of the extension numbers (4711, 4712).
CHANGE-SDAT:STNO=54711,TYPE=DATA1,STNOOOS=0004989-568-4711;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,STNOOOS=0004989-568-4712;
32
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
If you want to use only source group related incomplete alternate routing destination num-
bers, you have to administer the source group related alternate destination number with
outgoing trunk access to public network (004989) and with incoming trunk access (568) to
reach the Hipath 3000.
Furthermore, you must set the supplementary length (parameter EXTNO) to the length of
the HFA IP phones number in the HiPath 3000, which is = 4.
ADD-APRT:TYPE=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=0004989-568,EXTNO=4;
33
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
Scenario 1
CO Number:
+49-89-568
HiPath 4000 IP: 1.30.11.180 ISDN
STMI H G1 5 0 0
Moving by fault HiPath 3
000
IP: 1.40.41.180
IP
54711 Network
MOVING
954711
SUB-A
OOS-No =
0004989568954711
54712
954712
MOVING
TLN-B
OOS-No =
0004989568954712
or
Source-Grp = 2
ALT-No = 0049895689
with Extno= 5
● Device configuration:
34
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
AMO usage
– Calls to not reachable HFA IP phone, that have moved their logon location from HiPath
4000 to HiPath 3000, should be routed to the new logon location via public network. In
HiPath 3000, the HFA IP phones have a different number scheme than in HiPath 4000.
You must authorize those HFA IP phones, that can move their logon location from
Hipath 4000 to HiPath 300:
CHANGE-SDAT:STNO=54711,TYPE=DATA1,MVHFAIP=YES;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,MVHFAIP=YES;
You must set the gateway_IP address(es) for the source group(s), the HFA IP phones are
members of. This is necessary to avoid loops within HiPath 4000 and HiPath 3000 network.
For example, it could be possible, that a HiPath 4000 logged off HFA IP phone is not yet
logged on in HiPath 3000 and every switch tries to perform an alternate routing to the other
switch (ping/pong).
ADD-APRT:TYP=ALTERR,SRCGRP=2,ALRTYPE=OOS,GWIPADR=1.30.11.180;
For type= OOS, you must define either subscriber individual alternate routing destination
numbers for every HFA IP phone (A,B) or a source group related incomplete alternate rout-
ing destination number for the source group(s), the HFA IP phones are members of.
A incomplete alternate routing destination number will be supplemented at time of usage
with the extension number of the called HFA IP phone and with the administered length
(parameter EXTNO). This makes it possible to reach individual subscribers in other switch-
es.
If you want to use only subscriber individual alternate routing destination numbers, you
have to administer a subscriber individual alternate number for both HFA IP phones with
outgoing trunk access to public network (004989), with incoming trunk access to reach the
HiPath 3000 (568), with a number prefix (9) and the extension numbers (54711,5 4712).
CHANGE-SDAT:STNO=54711,TYPE=DATA1,STNOOOS=<0004989-568-9-54711;
CHANGE-SDAT:STNO=54712,TYPE=DATA1,STNOOOS=<0004989-568-9-54712;
If you want to use only source group related incomplete numbers, you have to administer
the source group related alternate destination number with outgoing trunk access to public
network (004989) and with incoming trunk access (568) to reach the HiPath 3000.
Furthermore, you must set the supplementary length (parameter EXTNO) to the length of
the HFA IP phones number in the HiPath 4000, which is 5:
ADD-APRT:TYP=ALTERR,SRCGRP=2,ALRTYPE=OOS,ALTRTNR=0004989-568-9,EXTNO=5;
35
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
2.2.1.4 Called subscribers (A,B) in its APs are in an APE situation to AP of the
calling device
Scenario 1:
APE situation
CO incoming:
4711 ISDN +49-89-723
AP 3700-IP
HiPath 4000
IP 4711
Network
4712
STN-A
OOS-NO =
001753333333
STN-B
ISDN
OOS-NO =
01753333333 001754444444
and
Source-Group = 17
ALT-NO for APE = 0004989723
01754444444 with EXTNO = 4
● Device configuration:
number (subscriber-A) = 4711
number (subscriber-B) = 4712
subscriber A,B in same source group 17
36
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
● What is possible?
All other alternate routing destination numbers, that lead to a valid internal or external
phone number, are possible.
The alternate routing destination number can be designed as outgoing public trunk access
or tie trunk access followed by an incoming trunk access to reach an AP.
The alternate routing destination number can be designed as a subscriber individual alter-
nate routing number or as a source group related incomplete alternate routing number
(with supplementation request).
If the alternate routing destination number is designed as a source group related incom-
plete number, the supplementation can only be done with the identical subscribers exten-
sion number (parameter EXTNO = length of subscribers extension number).
If the alternate routing destination number leads to a outgoing trunk access, only those
route elements will be used for alternate routing, that are defined as with " no internal re-
routing ".
● AMO usage
– Calls subscribers A,B, that are in an APE situation to the calling device, should be rout-
ed to the called subscribers in its AP via public trunk loop.
In case of APE, in the AP of the calling devices, it can not be verified, whether the called
subscribers in their own AP are in a seizable situation or not. Therefore, it makes sense, to
alternate route the call to the originally called subscribers in their own APs via public trunk
loop. The incoming trunk at target AP, then can verify for sure the real state of the called
subscribers.
For type = APE, you have to administer either subscriber individual alternate routing num-
bers of type = APE for subscriber A and B or incomplete source group related alternate
routing numbers of type = APE for the source group(s), the subscriber A,B are members of.
If you are sure, you don’t need different alternate routing destinations for TYPE = OOS and
TYPE=APE, you also can administer the mentioned alternate routing destination numbers
for TYPE = OOS.
37
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
With these settings in the Database, first the APE number is dialed by the host. If the dialing
of the APE number fails, the Mobile number (OOS) is dialed by the host.
38
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
Scenario 2:
APE situation
CO incoming:
4711 ISDN +49-89-723
AP 3700-IP
HiPath 4000
IP 4711
Network
4712
STN-A
APE-NO =
001711234567
STN-B
ISDN
ATND = 99 Source-Group = 18
ALT-NO for APE = 99
01711234567
● AMO usage
– Calls to not ready subscribers of source group 18 (STN-B), that are in an APE situation
to the calling device, should be routed to the attendant console. Calls to not ready sub-
scriber-A, of source group 18, that is in an APE situation to the calling device, should
be routed to a subscriber individual mobile phone number.
For type = APE, you must define a source group related complete alternate routing desti-
nation number for the source group = 18.
ADD-APRT:TYPE=ALTERR,SRCGRP=18,ALRTYPE=APE,ALTRTNR=99;
For type = APE and for subscriber-A, you must set the subscriber individual alternate rout-
ing number to the individual mobile phone number.
CHANGE-SDAT:STNO=4711,TYPE=DATA1,STNOAPE=001711234567;
39
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
If you are sure, you will not use different alternate routing destination numbers for OOS and
APE situations, it may be enough to define only alternate routing destination numbers for
the type = OOS.
ADD-APRT:TYPE=ALTERR,SRCGRP=18,ALRTYPE=OOS,ALTRTNR=99;
CHANGE-SDAT:STNO=4711,TYPE=DATA1,STNOOOS=001711234567;
40
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
41
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
42
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
– If the value of parameter EXTNO is > 0, a supplementation with the called subscribers
extension number is requested. This makes no sense in general, as this subscriber is
in OOS state and cannot be seized successfully, even if doing a loop over public or tie
trunk.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for this
routing scenario
4. In case of alternate routing type = APE or OOS because device/board error or deactivated
by AMO, the administered source group related alternate routing number contains the ac-
cess code for PSM/ PSE
● If the PSM/ PSE is designed with search length = 0, a supplementation is necessary
with the length of called subscribers number.
– If the administered parameter EXTNO is smaller than length of called subscriber, a
PSM search cannot be successful.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
The result is, that this alternate routing destination number can not be used for this
routing scenario
– If the administered parameter EXTNO is bigger than length of called subscriber, a
PSM search is possible.
The supplementation will done with the real length of the subscribers extension num-
ber.
– If the administered parameter EXTNO is bigger than maximum extension number
length, the command will be rejected by syntax check of AMO APRT
● If the PSM is designed with search length = x, a supplementation is necessary with
this length x
– If the administered parameter EXTNO is smaller than search length x, a PSM search
cannot be successful.
The implausibility of the source group related alternate routing destination number for
this routing scenario cannot be detected by the syntax checks of AMO APRT and will
only be verified at time of usage.
– If the administered parameter EXTNO is bigger than search length x, a PSM search is
possible.
43
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
44
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
45
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
46
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
Byte 35 length subscr indiv. alternate routing number fot type = APE
Byte 36 - 57 subscriber individual alternate routing number fot type = APE
Byte 58 length srcgrp related alternate routing number fot type = APE
Byte 59 - 80 source group related alternate routing number fot type = APE
Byte 81: number of supplementation digits for type = APE
Byte 82 - 85 gateway_IP-asdress (not used)
Byte 86 length subscr indiv. alternate routing number fot type = OOS
Byte 87 - 108 subscriber individual alternate routing number fot type = OOS
Byte 109 length srcgrp related alternate routing number fot type = OOS
Byte 110 - 131 source group related alternate routing number fot type = OOS
Byte 132 number of supplementation digits for type = OOS
Byte 133 - 136 gateway_IP address for HFA move logon
Byte 137 - 140 gateway_IP address in CPB
<
47
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
48
EN4416EN20EN_0003
© 2004 Siemens AG
General features: alternate routing on error Siemens
49
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General features: alternate routing on error
50
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Smart Card Application Siemens
S erver
optiP oint
optiPoint 500
500/600 (C A P /C A 4000)
S m art O ther
C ard S ignature optiP oint 410
optiPoint 400HFA
HFA S m artC ard Access
M odule optiPoint
optiP oint 600
600HFA
HFA H iP ath 4000 A p p licatio n S C A A A pplications
(S C )
A C L-C link
IS O
7816-4 C orN et-T S C orN et-T S A C L-C LA N
A Smart Card is plugged into the Signature module, authentication is then carried out in an
external server with the application "SmartCard Access Application SCAA".This is connected
to the HiPath 4000 via ACL-C and the CAP/CA4000 application.The results of the Authentifi-
cation by the application "SmartCard Access Application SCAA" can be used by other applica-
tions which can communicate with the application SCAA on the server..
51
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Smart Card Application
The user interface to identify the user is controlled via SmartCard (Local Security check Pro-
cedure) by means of a Card ID which interfaces with the SmartCard Access Application SCAA
for the identification of the user.
The Smart Card Access Application SCAA takes control of the telephone display by placing it
into the Non-Voice condition and the Non-Voice LED is turned on.
The entered numbers of the Card ID are not seen on the display. The end of dial condition
( such as "#" or number of ID numbers) is configured in the Smart Card Access Application
SCAA .
After successful authentication from the Smart Card Access Application SCAA on the server
has been initiated,then the subscriber identified by means of the smart card has the feature
"mobile subscriber" activated. The input of the subscriber phone number which was neces-
sary with the chip card for Optiset E is not necessary with the SmartCard.
After inserting the card and successful activation of the feature "mobile user"the station has the
rights and special features of the smart card user (dial plan membership,traffic restriction
group,etc).This is also the case when a smart card is inserted while during a connection,with
another smart card or "Pin Manual".
Attention:
7 The implementation of the feature in the Hipath 4000 V2.0 is dependent on the
availability of the Application (SCAA) !
52
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Smart Card Application Siemens
53
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Smart Card Application
54
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
4 HG3550V2.0 WAML-replacement
4.1 General
The following scenarios give a summary of the application cases for the HG3550v2.0 WAML
Replacement .The exact description of the configuration of the second scenario (LAN-WAN) is
not part of this document ; this is covered by the configuration manual (HiPath 4000 Manager).
The HG3550 V2.0 is not intended to replace the WAML board.The purpose of the HG3550 V2.0
WAML is to make LAN Connectivity to UW, so that Remote Access(RAS) to the HiPath 4000
administration by means of HiPath assistant/manager is possible .(feature "Serviceability").
The LAN Connectivity is a feature which provides 2 Ethernet LAN interfaces and an ISDN con-
nection.
The Board required to this purpose is the HG3550 V2.0. With this board there is the possibilty
to attach an external LAN to the Hicom or HiPath 4000 and to make data transmission via the
ISDN network, from an arbitrary subscriber, into the Atlantic LAN (ATLLAN) and to the HiPath
assistant, provided that the required rights are existing.
To be able to use the LAN Connectivity, you must establish specific configuration data for the
WAML with WBM, after setting up the board with the appropriate AMOs. Only after this the
LAN Connectivity operational. On this occasion the configuration is not checked for consis-
tency with the topology of an existing network (e.g. IP-addresses).
An integrated LAN/ISDN Router function controls the transmission of the Data Packets
between the WAML Network interfaces.
These implementations are made possible:
● SCN-LAN
HiPath 4000
customer
H LAN
PSTN *) G
S0/S2 35
50
S0
H
U
B
ADP C Atlantic
LAN
e.g.. HTS
*) DIUS2 /.STMD
55
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
● LAN-WAN
H H
U U
B B
e.g. DMS Atlantic C ADP ADP C Atlantic
LAN LAN
*) DIUS2/ STMD
56
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
4.2 SCN-LAN
The PC with the phone numbers 7374 shall be allowed to dial in via an ISDN connection with
the phone number 80313 and access the UW7 ( IP address 192.0.2.5) via the Atlantic LAN. To
UW7 only PPTP connections are possible. The PPTP server in the UW7 (UBA) is configured
in this example in this way, that it allocates the IP-address 10.32.192.5 as virtual remote IP-
address.To this IP-address (10.32.192.5), UW7 uses the IP-address 10.32.254.193 (virtual lo-
cal) as gateway to the HG3550 V2.0. This is a fix address, set by the system. The allocation of
these IP addresses is fixed in the "VPN ADDRESS Space of HICOM 300 H for Hipath4000
V2.0". For this connection a CHAP authentification is required
(in this example; User: HG3550, password: 1234).
HG3550V2.0
ISDN 80313 LAN
Dial-up: 10.1.192.5
10.32.252.65
CLAN: 1.30.31.180
ATLAN: 192.0.2.4
Virtual: 10.32.254.193
CC local
ADP
UW7: 192.0.2.5
Virtual: 10.32.192.5
remote
57
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
4.2.1.1 Adding the STMI2-IGW board and configuring the board data
● Assign Flexama Memory for STMI2-IGW configuration data with AMO DIMSU :
ADD-DIMSU:TYPE=SYSTEM,STMI2IGW=<number>;
● Adding the Board at LTU=2 and SLOT=25 (Q2316-X with 60 B-Channels, Q2316-X10 with
120 B-Channels):
ADD-BCSU:MTYPE=PER,LTU=2,SLOT=25,PARTNO="Q2316-X",FCTID=5;
CHANGE-STMIB:MTYPE=STMI2IGW,LTU=2,EBT=251,TYPE=IFDATA,ATLIP=192.0.2.4;
58
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
● Adding the Trunk HG3550 V2.0 LAN-Connectivity (for Q2316-X pen 1, for -X10 pen 3 is to
be used):
ADD-TDCSU:OPT=NEW,PEN=1-2-25-1,COTNO=<number>,COPNO=<number>,
COS=<number>,LCOSV=<number>,LCOSD=<number>,CCT="WAML_REP",ATNTYP=TIE,
PROTVAR=ECMAV2,SEGMENT=8,NNO=<numb.>,DEV=HG3550LA,TGRP=355,BCHAN=1&&30;
59
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
DISPLAY-SDSU:STATUS=ALL,TYPE=PEN,LEVEL=PER3,LTG=1,LTU=2,SLOT=25;
RESTART-DSSU:TYPE=PEN,PEN1=1-2-25-1;
● Prevent new loading of the Loadware from harddisk, if the board is reset (faster loading):
CHANGE-FUNSU:PIT=FLASH,PARTNO="Q2316-X",FCTID=5,ACTION=RESET;
60
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
● The “PPP Links Details” message has to be filled out at the time, but the settings are not
used.
61
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
● Start the PPTP connection (in this example. Name: HG3550, Secret: 1234)
62
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
63
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
To change settings or to add new entries in the WBM - Explorer of the HG3550
V2.0, click with the right mouse button on the entry, which should be used.
64
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
65
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
66
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
67
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
68
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
69
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
70
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
3rd Logoff
71
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
Installing: Start -> Settings -> Network and Dial-up Connections -> Make new
Connection
72
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
73
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
Select:
Properties
Select:
General
74
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
Select:
Networking
Select:
Settings
75
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
Select:
TCP/IP
Properties
Select:
IP address
Advanced...
76
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
Select:
General
Deactivate
77
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
Instruction: Home Page HiPath 4000 Assistant -> Clicking on “i” of “HiPath 4000 V2.0”
78
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
ADD-SBCSU:STNO=7374,OPT=FBUS,CONN=DIR,PEN=1-2-37-5,DVCFIG=SET600&DTE,
COS1=131,COS2=131,LCOSV1=9,LCOSV2=1,LCOSD1=9,LCOSD2=1,DPLN=0,ITR=0,
SSTNO=N,COSX=0,SPDI=0,SPROT=SBDSS1,DPROT=SBDSS1,PERMACT=Y,INS=Y,
ALARMNO=11,SOPTIDX=10,DOPTIDX=10,EXTBUS=Y,RCBKB=N,RCBKNA=N,
CBKBMAX=5,HMUSIC=0;
79
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: HG3550V2.0 WAML-Replacement
Select:
Dial
80
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: HG3550V2.0 WAML-Replacement Siemens
81
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
5.1 ADP
A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
ACMSM 4 4 4 4 4
AFR 5 5 5 0 0 0 5 5 5
ANUM 2 0 2
APC 0 0 2 2 2
APP 3
APS 0 0 2 2 2
ASPIK 2
ASSGN 2 0 2 0
ATCSM 2 2 2 0 2
AUTH 10 0 2
BACK 2 2 2 0 2 2 2 2 2
BCSM 2 2 0 2 2 2
CABA 2 2 2 2 2
CDBR 2 0 2 2
CDSM 0
CLIST 2
CMP 2
CMUID 5
82
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
CONSY 2 2 2 0 2 2
COPY 3
CPCI 2 0 2
CPSM 2 2 2 0 2
CPTP 2 2 0 2
CRON 5 5 5 0 2
DAGR 1 1 1 1 2 1
DASM 2 2
DATE 2 0
DAVF 1 1 2
DCSM 2 2 2
DDRSM 2 2 2 5
DDSM 0 2
DEBUG 3 3 3
DEFPP 2 2 2 0 2
DEFTM 2 2 2 0 2
DEL 3
DISPA 3 3
DLSM 2 2
DSSM 2 2 2 2
DPSM 2 2
DTSM 2 2 2 2
83
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
DUP 3
DVU 2 2 2
FAMOS 2 2 0 2 2 2
FAMUP 2 2 2 2 2 2 2 2 2 5
FBTID 2 2 2 2
0
FBTN 1 1 1 2
FEACG 4 4 0 2
FETA 1 1 1 2
FINF 2 2
FORM 3
FTBL 1 1 1 1 1
FTCSM 2 2 2 2 2
FTRNS 2 0 2
FUNCT 2 0 2
GEFE 2 0 2
GENDB 5
GETAB 1 1 0 2 1 1
GETPD 0
GEZAB 1 1 1 1 1 1 1
GEZU 2 2 2 0 2
GRA 2 2
GRZW 1 1 1 0 2
84
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
HISTA 2 2 2 0 0 2 2 2 2
INFO 2
INIT 3 0 3
JOB 5 0
KDEV 1 1 1 1 1 1
KDGZ 1 1 1 0 1
LCSM 2 2 2 0 2
LDB 3
LIST 2
LOGBK 5 5
LSSM 0 2 2 0
PASSW 5 5 5 5 2
PATCH 2 2 2 0 2 2 2 2
RCUT 1 1 1 1 2
REGEN 5
REN 3
REST 2 0 0 2
SAVCO 3
SAVE 3
SDSM 0
SELG 1 1 1 1 2 1
SELL 1 1 1 2
85
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
A C D D R O A D S S S S E O C D D I U S
D H E I E U C E W T T E X U O U I N M A
D A L S G T T A I A O T E T P M A P B M
N E P E P I C T R P C P Y P L U E M
G T L N U V T C T U O T N E
E E A E T A I H T G N L
Y R T V O . E N
A E A V . N
T T E .
E E R
SELS 0 2 1 1 1 1
SIGNL 2 2 2 0 2 0 2 2 2 5
SONUS 2 0 2 2
SPES 2 2 0 2 2 2
SYNC 5 0 5 5
TABT 1 1 1 1 2
TCSM 2 2 2 0 2
TEST 0 0
TEXT 1 1 0 2
TINFO 2 0 2
TLZO 1 1 1 1 2
TRACA 2 2 2
TRACS 2 2 2
TTBL 1 1 1 1 2
UPDAT 2 0 2 2
USER 10 10 10 0 2 10 10 2
UW7 5 5 5
VADSM 2 0 2 2 2
VEGAS 2 2 0
XAPC 0 0 0 0
86
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
5.2 CC
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
ACDGP 2 2 2 0 2
ACDRS 2 2 2 0 2
ACDRT 2 2 2 0 2 4 2 2
ACDSD 2 0 2
ACSU 2 2 2 0 2
ACTDA 2 2 0 2
AGENT 2 2 2 0 2
ANSU 2 0 2
APRT 2 2 2 2 2
AUN 2 2 2 0 2
AUTHO 0
BCSU 2 2 2 0 2
BDAT 2 2 2 0 2 2
BGDAT 2
BERUM 2 0
BERUZ 2 0 2
BGDAT 2
BPOOL 2 2 2 0 2
BSSU 2 2 2 2 5
BUEND 2 2 2 0 2
CDSU 0
87
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
CHESE 2 2 2 0 2
CODEW 5 3 5 5 3 5
COMGR 2 2 2 2 2
COP 2 2 2 0 2 2 5
COSSU 2 2 2 0 2
COT 2 2 2 0 2 2 5
CTIME 2 0 2
DBC 3 5 0 0 3
DBSUM 0
DCIC 2 2 2 0 2
DIAGS 2 0 5 5 5
DIDCR 2 2 2 0 2
DIMSU 4 0 2 4 0
DISPS 3 3 3 3
DNIT 2 2 2 0 2
DSSU 2 2 2 2 5 2 5
DTIM1 2 0 2
DTIM2 2 0 2
FEASU 4 0 2
FUNSU 2 0 2 2
GKREG 2 2 2 2 2
GKTOP 5 5 5 5 5
88
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
HFAB 2 2 0 2 2
HIDMP 2 2
HOTLN 2 2 2 0 2
KCSU 2 2 2 0 2
KNDEF 2 2 2 0 2
KNFOR 2 2 2 4 4 4
KNLCR 2 2 2 0 2
KNMAT 2 0 2
KNPRE 2 2 2 0 2
KNTOP 2 2 2 0 2 2
LANC 2 2 2 0 2 2 2
LAUTH 3 3 3 4 4
LDAT 2 2 2 0 2
LDPLN 2 2 2 0 2 2
LDSRT 2 2 2 0 2
LEMAN 2
LIN 2 2 2 2 2
LODR 2 2 0 2
LPROF 2 2 2 0 2
LRNGZ 2 2 2 0 2
LSCHD 2 0 2
LW 0
89
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
LWCMD 3
LWPAR 2 2 2 0 2 2
MFCTA 2 0 2 2
NAVAR 2 2 2 0 2
PERSI 1 1 1 1 1
PETRA 2 0 2 2
PRODE 2 0 2 2
PSTAT 2 2 2
PTIME 2 0 2 2
RCSU 2 2 2 0 2
REFTA 2 2 2 0 2 2
RICHT 2 2 2 0 2
RUFUM 2 2 0 2
SA 2 2 2 0 2
SBCSU 2 2 2 0 2
SCREN 2 2 2 0 2
SCSU 2 2 2 0 2
SDAT 2 0 2 5
SDSU 0
SIPCO 2 2 2 2 2
SSC 2 2 0 2
STMIB
90
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
SSCSU 2 2 2 0 2
STMIB 3
SXSU 2
SYNCA 2 2 2 0 2 2
TACSU 2 2 2 0 2 5 5 5
TAPRO 2 0 2 2
TDCSU 2 2 2 0 1 2 2
TGER 2 2 0 2
TREF 5 0 2 5 5
TSCSU 2 2 2 0 2
TSU 2 2 5
TWABE 2 2 0 2
UCSU 2 2 2 0 2
UPLOL 5
UPLO2 5
USSU 2 2
VADSU 2 2 2 0 2 2 2
VBZ 2 0 2
VBZA 2 0 2
VBZGR 2 2 0 2
VFGKZ 2 2 2 0 2
VFGR 2 2 2 0 2
91
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: AMO Authorizations
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
VOICO 2 2 0 2 2 2
WABE 2 2 2 0 2
XAPPL 4 4 4 0 4
ZAND 2 0 2 5 5 5
ZANDE 2 0 2
ZAUSL 0
ZIEL 2 2 0 2
ZIELN 2 2 0 2
ZRNGZ 2 2 0 2
92
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: AMO Authorizations Siemens
A C D D R O A D S S S S E O C D T R D I O D
D H E I E U C E W T T E X U O U E E I N P I
D A L S G T T A I A O T E T P P S S A P T A
N E P E P I C T R P C P Y T T L U I G
G T L N U V T C T U A O T M N
E E A E T A I H T R G I O
Y R T V O T . Z S
A E A V . E E
T T E .
E E R
BST 0 0 0
PSA 0 2 2 2
PSS 0 2 2 2
93
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens
6.1 AMOs
ACSU
– ACTYPE = AC4, ACW2Q und ACWMQ
– New ACWIN-Software for Windows XP: ACWIN 5.0 and ACWIN MQ 3.0
(DS-WIn 3.0 and BLF-Win 3.0 are necessary for ACWIN 5.0 and MQ 3.0.
ASC 3.0 (Hicom 300H) resp. ASC 4.0 (HiPath 4000) are necessary for ACWIN 5.0.
With ASC 5.0 both ACWIN variants can be used.)
BCSM
– DEACTIVATE-BCSM:UNIT=A1,SYSTEM=UNIX; -> Unix-Boot is blocked for the next
Unix-Restarts after the ADP-Data base is updated;
EXEC-UPDAT:UNIT=A1,SUSY=ALL;
– ACTIVATE-BCSM: UNIT=A1,SYSTEM=UNIX; -> Unix-Boot is started;
EXEC-UPDAT:UNIT=A1,SUSY=ALL;
BUEND
– Parameter RSV falls out.
94
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens
CPCI
– DISP-CPCI; Shows, which transfer mode are set for LAN in-
terfaces “Service” and “Atlantic” of the DSCXL
board, if the DSCXL board is used as ADP.
Additional is shown, if the switch is a DUAL or
MONO system, and if RTM modules are in-
stalled or not (important for generating a sys-
tem).
– CHA-CPCI: TYPE= Setting in which mode the LAN interfaces “Ser-
FRONTPAN vice” and “Atlantic” of the DSCXL board should
work, if the board is used as ADP or CC-AP.
(10 or 100 Mbits full or half duplex)
TYPE= Setting, if the switch is a MONO or DUAL sys-
SYSCONF tem, and if RTM modules are installed.
MONO Mono or Dual configuration (YES / NO)
RTM RTM board installed (YES / NO)
COP
– New parameter: LCOS -> Limitation of LAUTH to 32 for transfering;
– Parameters RES 162-171fall out;
COSSU
– The LCOSV- and LCOSD-classes can be increased up to 1000.
The highest number of the class depends on
AMO DIMSU:TYPE=USER,LCRCOS=xxxx;
95
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000
COT
DIMSU
● USER
– LCRCOS Maximum number of LCOSV/LCOSD in AMO COSSU;
This is th highest number, which could be added in AMO COSSU; i.e. if 50 is set the
class 51 can not be added in AMO COSSU.
– ALTROUT Number of alternative numbers for subscribers, ATNDIND and AP-Emer-
gency, (OOS and APE);
– SLKTEXT Number of SLK keys with individual text;
– CALLOGS Number of devices with Self Labling feature (SLK);
– HOTDEST Number of Hotline destinations (up to 65535)
● NETWORK
– LDPLN1-8 LCR dialing plan 1-8; LDPLN1 for Standard LCR, LDPLN2-8 for Large
Gatekeeper;
– LDPLNC1-8 LCR dialing plan Cache; LWMC1 for Standard-LCR, LDPLNC2-8 for Lar-
ge Gatekeeper;
● SYSTEM
– STMIHFA2 Number of STMI2 boards (HG3530V2.0) for the feature HFA;
– STMI2IGW Number of STMI2 boards (HG3550V2.0) for the feature IP-Trunking V2;
– GWREG Number of internal and external Gateways (feature LEGK);
– CCAP Number of Emergency APs (feature APE);
96
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens
FUNCT
– LOGBKOFF Prevents logbook entries (values 0-8):
– 0= none
– 1= DISPLAY-BUEND (cause: Traffic monitoring in the Assistant)
– 2= EXEC-UPLO/UPLO2
– 3= REGEN-CPTP
– 4= CHANGE-FUNCT;
2+3+4 are often used by UNIX.
HOTLN
– In branch: HOTDEST, destinations are increased to 2512;
LDAT
– Number of LRTEs is increased to 64000;
LDPLN
– Two new branches in parameter LCRCONF:
1. LCRPATT:
● DIPLNUM (0-2047)
In standard the DIPLNUM=0 is to be used;
DIPLNUM=0 is fixed and can not be changed or deleted;
Is used for 1:1 converting from HiPath 4000 V1.0 without the feature LEGK (Large
Enterprise Gatekeeper)
97
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000
2. LCRADM
● DIPLNUM (1-2047)
● LWMPOOL (1-8) -> DIMSU:NETWORK,LDPLN1-8
● DIALPLN (0-255)
LPROF
– Profile indexes are increased to 3000;
LSSM
– Switching the new LAN interfaces (LN=1-6,TYPE=LAN) at the cPCI-Shelf.
PATCH
– The noun REGENERATE for optional Patches is new;
RCSU
● New parameter branch for IP connections;
– CLASSMRK
RICHT
– Number of LRTEs increased to 64000;
SSC
– New parameter branch for IP connections with EXTANN:
● CLASSMRK
98
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens
TAPRO
– 256 key layouts;
– The TIME key shows during calls the time at the display for 10 seconds
(now usable for all opti);
VFGR
– Parameter CQMAXF falls out;
XAPPL
– The new parameter TSKA has to be set to YES in the application 92 (TSKA), if you
want to use the application in the HiPath 4000 Assistant V2.0;
ZAND
● ALLDATA
– DSSLT (Number of direct station select partners) increased to 70;
● ALLDATA2
– HOTELNUM Entering a number between 0 and 9 (number length of hotel stati-
ons);
– DISPREST Display name independent of supressed number;
– Parameter falls out: INDNADIS; the new parameter is DISPREST
● ALLDATA3
– CFNRDEST Call forward on no reply to the deactivated fixed call forward
destination (value USECFUF) (old CF concept). For the value
ONLYCFNR the special CF destinations (CFNR und CFB) are used
(new CF concept);
– EXANTRF external announcement after transfer;
– IPDAVCCF Voice Compression for IPDA connections in conference or
announcement situations;
99
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000
● OPTISET
– PUSECOK Pick up of second call enabled with OK key;
– CALLOG Supress the deletion of callog entries in the Service menu;
● CIT
– Parameter UMKOV falls out;
ZANDE
● ALLDATA
– SCALLOG Y -> Source number in callog;
After transfer the transfered subscriber (Subscriber_A)
is registered in the callog of the Subscriber_C;
N -> After transfer the transferring subscriber (Subscriber_B)
is registered in the callog of the Subscriber_C;
– VCANNCNF Y/N -> Voice Compression for conference and announcement
situations;
– H235SEC Y/N -> Activates / deactivates H.235 Security for STMI2IGW
boards;
– GATEKPR Y/N -> PBX with Large Enterprise Gatekeeper (LEGK);
– DECTPS Y/N -> Via this parameter the DECT Positioning System (laca-
ting of DECT Mobile phones) will be activated resp.
deactivated;
– NONPIIW Y/N -> For detailed describtion see ComWin300 Edit; (only
used in US);
– DAJB Y/N -> The configuring of the Jitter Buffer is not possible in the
WBM of a STMI2 board, if this parameter is set. The set-
ting in AMO STMIB branch DSP are used;
– NOVNIDCO Y/N -> Since HP4K V1.0 AMO KNMAT corrects the virtual
node ID to avoid dependences from node to node in dif-
ferent regions.If NOVNIDCO=YES is set, this behaviour
is disabled, what means, that the KNMAT modification
works like HP4K V1.0 before.
– IMPRPKZ Y/N -> If this parameter is set, both levels of one name key can
be chained for PKZ usage;
100
EN4416EN20EN_0003
© 2004 Siemens AG
General Features: Extended features and AMO changes in the HiPath 4000 Siemens
– SILMON Y/N -> If this parameter is set, Silent Monitoring is only possible
for member of the ACD group of the monitorer. If this pa-
rameter is not set, there are no restrictions to any ACD
groups.
● OPTISET
– EDITDIAL Y/N Edited dialing for Up0E terminals (Deleting of single
numbers by using with the arrow key (positioning) and
the “-” key; For starting the call, use the OK key);
● MLPP Multi-level precedence and preemption service;
Special feature for the army (US);
● AMO usage
In AMO ZAND the CLIP standard is set for the whole system. AMO BCSU and SCSU are used
for adding the SLMAC board and the analoge subcribers. AMO FEASU is used for activation
or deactivation of the CLIP analoge.
ADD-BCSU:MTYPE=PER,LTU=XX,SLOT=XX,PARTNO="Q2191-C";
2. Adding of CLIP analoge subscribers with AMO SCSU (Without using parameter DHPAR):
ADD-SCSU:............................;
101
EN4416EN20EN_0003
© 2004 Siemens AG
Siemens General Features: Extended features and AMO changes in the HiPath 4000
● Generating VMWI
The feature is activated, when the SLMAC is used and the CLIP function for analoge phones
is activated.
● Restriction
The MWI/Mailbox signalling with fluorescent lamp (150 V) is not supported!
● Special cases
The feature CLIP for analoge phones is activated. The analoge phone has the MWI display
based on COMTEL. In this case the parameter DHPAR=LEDSIGN must be set in AMO SCSU
(SPEC= SUFDIAL or SOD).
102
EN4416EN20EN_0003
© 2004 Siemens AG