Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

M1568BS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical Information Rev.

M1568BS
X-Band Magnetron
M1568BS is designed for the magnetron of x-band radar system. The frequency range is fixed <93809440MHz> and the peak output power is 25kW.

MAXIMUM RATINGS
Min Peak anode current Peak anode power input Duty cycle Pulse duration Rate of rise of voltage pulse Anode temperature 6.0 0.05 Max 10 75 0.001 1.2 90 110 1.5:1 Unit A kW s kV/s -

V.S.W.R at the output coupler

ELECTRICAL
Min Heater voltage (Note 1) Preheat time Peak anode voltage (Note 2) Peak output power (Note 2) Frequency (Note 2) 7.0 120 7.2 22.5 9380 Typical 7.5 8.0 25 9410 Max 8.0 8.5 9440 Unit V S kV kW MHz

Note 1: Measured with heater voltage of 7.5V and no anode input power, the heater current 1imits are 0.43A minimum, 0.6A maximum. For average pulse input powers greater than 25 watts the heater voltage must be reduced within 3 seconds after the application of h. t. according to the following schedule: Heater Voltage : Ef = 7.5 1 Pi :Input Power (Average)[W]

Pi [V] 87

Note 2: Measured at peak anode current 8.0A 1-1,Fukuoka 2-chome, Fujimino-city Saitama-prefecture 356-8510 Japan Phone:049-278-1298 Fax :049-278-1419

Technical Information Rev.5


Note 3: Any overshoot of the anode current is not acceptable. The impedance of this magnetron is the same as current magnetron excluding the transient impedance. This means that the additional reactance should be required for adjustment the anode current wave form, if this magnetron will be installed into the similar modulator circuit as before.

1-1,Fukuoka 2-chome, Fujimino-city Saitama-prefecture 356-8510 Japan

Phone:049-278-1298 Fax :049-278-1419

You might also like