Drill Pipe Inspection Tally Sheet: International Limited
Drill Pipe Inspection Tally Sheet: International Limited
Drill Pipe Inspection Tally Sheet: International Limited
CUSTOMER: SEADRILL P.O. NO.: SIZE 5.7/8" SPECIFICATION ID No. GRADE S - 135 DS1 STD
489909
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com LOCATION: JCI BASE T 26 A
REPORT No.:2903
WEIGHT 26.70 Lbs CATEGORY 1 2 NOM. WALL THICKNESS 0.415" 3 4 BOX TOOL JOINT Min
Wall Thick.
20-03-2012
HDLS
HARDBANDED
YES
PIPE BODY OD
Wear Corrosion Int.Coat
A A A
7 7 7
ACC SD ACC
OK OK OK
7 7 7
10 10 8.29/32
Int.
Ext.
Cond.
EM
en t
on
Dia
Depth
Dia.
Width
Space
Upset
Dia
Width
Width
Length
Space
on
OD
HB COND
Bevel
Counterbore
Seal Width
Shldr.
Tong
MPI
Bevel ID OD
Seal
Shldr.
Neck
d.
d.
FINAL CLASS
Length
Ft.
REMARK
Joint with Pin for Repair Joint with Box for Repair Joint with Pin & Box for Repair Pin Refaced / Rebeveled Box Refaced / Rebeveled Bent Pipes
0 0 0 0 0 0
REMARK
SD = Seal Damage TD = Thread Damage BB = Belled Box ST = Streched Thread PT = Pitted Thread PS = Pitted Seal GT = Galled Thread WO = Wash Out
CLASSIFICATION
CRK = Crack STJ = Short Tool Joint HBD = Hard Band Damage RF = Refaced ACC = Acceptable REJ = Rejected NA = Not Applicable
Inspector :
SIMON OGBAN
Sign Date
20/03/2012
Member