Biomechanics
Biomechanics
Biomechanics
STRUCTURE OF BONE
Bone
Cellular Component
Extracellular Component
Triple helix tertiary twisted structures. High tensile strength and flexibility.
Crystals are aligned along the axis of the collagen fibres provide reinforcement. Provide strong and tough composite
Cortical bone
Trabecular bone
more dense ( porosity 5% to 10%) found on surface of the bones ( shaft of long bones, forms outer shell around cancellous bone at the end of the joints and vertebrae) structural and functional unit is called the osteon
Less dense ( porosity 50% to 90%) Found in end of long bones, vertebrae and flat bones. Also found in the inside of the bone. Structural and functional unit is called the trabecula
Cortical Bone
holes within the bone matrix which contain bone cells(osteocytes) and their processes. Osteoblasts become entrapped and mature into osteocytes during the process of mineralization, ellipsoidal structure. Within the lacunae the osteocytes sit within the extracellular fluid.
Osteocyte Canaliculi
small tunnels that connect one lacunae to the other. These interconnections provide a pathway though which osteocytes can communicate information.
Only found in secondary bone result of remodelling. Occurs at the point bone resorption ends and bone formation begins. Devoid of collagen type 1 CEMENT LINES MAY SERVE TO ARRESST CRACK GROWTH IN BONE BEING THAT THEY ARE VERY COMPLIANT AND LIKELY TO ABSORB ENERGY
Source: http://training.seer.cancer.gov/anatomy/skeletal/tissue.html
Source: Grays Anatomy of the Human Body from the classic 1918 publication available online at Bartleby.com. Coloured and modified using Adobe Illustrator
Trabecular Bone
Structural unit Trabacula - Components are the same as that of cortical bone. - Difference lies in the organization of microstructures. - Trabacula is 200nm in thickness and 1000nm long. - Do not contain central canal with blood vessel. Blood vessels surround the trabacula. - Lamallae are not concentrically arranged but arranged longitudinally along the trabacula.
BIOMECHANICS OF BONE
The whole bone properties are called extrinsic biomechanical properties. Bone tissue properties are called intrinsic properties.
Source: Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality C. H. Turner
Source: Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality C. H. Turner
Ultimate strength
Tension
133 MPa
Compression
193 MPa
Shear
68 MPa
STRAIN
The amount of deformation in the material, relative to its original length, is called strain.
Material is pulled, it gets longer - tensile strain Material is pushed together, it shortens - compressive strain Layers in the materials slide against each other, occurs with torsion or bending - Shear
Absolute magnitudes of peak strains in bone during vigorous activity can be on the order of 3500 micro strain in compression (0.35% strain), 1200 micro strain in tension.
Material A
Material A is stiffer compared to B. - Steeper slope Material B has a higher yield strain than A - more linear relation between stress and strain ( Yield Failure)
Material B
Material A has a higher ultimate strain when compared to B - gives the Ultimate Failure. Material A is more brittle than B - Area under the graph gives the toughness of the material
MODULI
Stiffness is determined by the relative proportions of the hydroxyapatite crystals and the collagen fibres that make up the composite. The steeper the slope of the stress vs strain graph, the greater is the modulus and bone deforms much less.
18 GPa in the longitudinal direction 12 GPa in the transverse direction, 3.3 GPa in shear The material properties of cancellous bone are influenced by trabecular orientation, connectivity and bulk density The elastic modulus of trabecular bone can range from 0.1 to 3.5 GPa. The degree of mineralization (e.g., immature or woven bone) or porosity (e.g., old bone) will compromise the stiffness of the bone and thereby lower the elastic modulus.
Young's modulus of trabecular bone as a function of density of bone. Bone density is expressed in g/cm3 and Young's modulus E in MPa
YIELD FAILURE
When strain is no longer proportional to stress, the material loses it ability to resume its original shape. In the bone, yield failure arises through ultra structural micro cracks within the hydroxyapatite and the disruption of collagen fibrils. The yield stress is approximately 130 MPa. The yield strain of cortical bone is on the order of 6800 micro strain.
Ultimate Failure
As the loading continues in the plastic region, the material will eventually reach ultimate failure and fracture. The point at which the bone breaks can be viewed as either the ultimate strain. - 10,000-15,000 micro strain in tension - the ultimate stress i) 140 MPa in tension ii) 200 MPa in compression iii) 65 MPa in shear
Toughness
The area under the stress strain graph gives the energy per unit volume possessed by the material at any given point.The area gives the energy required to break the object i.e. it gives the work to failure. The property is measured as the toughness of the material. The composite nature of Haversian, circumferential and interstitial lamellae play an important role in defining the toughness of the bone.
The amount of post-yield strain that occurs before ultimate failure is a measure of the material's ductility, reflecting its ability to resist the propagation of cracks.
Osteopetrosis : Brittle bone disease. The bone undergoes little deformation before fracture. This disease causes stiff, brittle bones.
Osteomalacia : This results in weak, ductile bone. Bones can deform considerably before the fracture. The bones bend under load and deform ( bowed long bones)
Both osteopetrosis and osteomalacia , the bone is unable to absorb energy before breaking. i.e there is reduced work to failure.
Source: Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality C. H. Turner
Source: Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality C. H. Turner
Where, k = constant, P =porosity Strength porosity relationship for bone, the value on N falls between 2 and 3.
Source: Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality C. H. Turner
Stiffness and toughness are the basic requirements of a bone. It is not possible to attain high stiffness and toughness simultaneously. There is an inevitable trade-off between both the properties. A delicate balance between resistance to propagate cracks provided by collagen and resistance to deformation ( given by the hydroxyapatite crystals).
Compression
The cortical bone is stronger in compression than in tension. The strain to failure is about 3% for cortical bone under compressive loading regardless of whether the load is applied travresely across the bone or longitudinally along the bone.
When the bone is loaded transversely in tension, the strain to failure and strength is reduced substantially.
Transverse specimens are much weaker and exhibit much lower strain-to-failure than longitudinal specimens.
Property
Compressive strength(MPa)
Tensile strength Strain to failure Youngs Modulus Fracture toughness
Cortical Bone
100-200
50-150 1-3 7-30 2-12
Cancellous Bone
2-12
10-20 5-7 0.5-0.05
Source: Table 8.2, The skeletal system, LARRY HENCH Biomaterials, Artificial Organs and Tissue Engineering
Viscoelasticity is a phenomena of time dependent strain exhibited by amorphous materials. Viscoelasticity has been attributed to viscous-like motion at the cement lines and the presence of a water phase. Viscoelasticity can be explained in terms of Creep Stress relaxation Viscoelastic parameters : Elastic (storage) modulus : The ability of a material to store energy Viscous (loss) modulus : The ability of a material to dissipate energy.
Creep
It is a tine dependent increasing strain response to a constant applies stress.
Stress Relaxation
It is a time dependent reduction of stress response to a constant applied stain.
BONE REMODELLING
Adjust bone architecture to meet changing mechanical needs. Modification of bone in response to stress other biomechanical forces. Helps to repair micro damages in bone matrix by preventing the accumulation of old bone. Maintaining plasma calcium homeostasis.
Cortical Bone
Trabecular Bone
Cylindrical 2,000m long and 150200m wide Speed of 20-40 m/day 2% to 5% of cortical cone is remodelled each year.
More actively remodelled Trench of depth 40-60m Larger surface to volume ratio Speed of 25m/day
Osteoblasts and osteoclasts arranged in BMU (site of bone remodelling). BMUs vary from cortical bone to trabecular bone(morphology).
Resportion
Formation
Reversal
References:
1. Biomechanics of Bone: Determinants of Skeletal Fragility and Bone Quality , C. H. Turner Biomechanics and Biomaterials Research Center, Indiana University, Indianapolis, USA 2. Bone Remodeling DIMITRIOS J. HADJIDAKIS AND IOANNIS I. ANDROULAKIS Second Department of Internal Medicine, Propaedeutic, and Research Institute, Athens University, Attikon University General Hospital, Athens, Greece 3. biomech.byu.edu/Portals/83/docs/exsc362/.../bone_biomech.pdf 4. www.engin.umich.edu/class/bme456/bonestructure/bonestructure.htm 5. http://www.feppd.org/ICBDent/campus/biomechanics_in_dentistry/index.htm#index 6. http://www.teambone.com/biomechanics.html