Summation CT
Summation CT
Summation CT
DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921210113B
6 KSU 3
3 3
7 SUSK 3
3 3
8 SUSK 4
3 3
9 SUSK 5
3 3
10 SUSK 6
3 3
11 SUSK 7
3 3
12 SUSK 8
3 3
Current Current Current Current Current Current Current Current curcuits curcuits curcuits curcuits curcuits curcuits curcuits curcuits
Page Primary nominal current A 1 2.5 5 10 15 20 25 30 40 50 60 75 80 100 125 150 200 250 300 400 500 600 750 800 1000 1200 1250 1500 1600 1800 2000 2500 3000 3200 4000 5000 6000 7500 Primary conductor in mm Round conductor in mm Transform. width in mm
* For the current transformers above, click-on mountings are available for fitment onto 35mm DIN-rails (DIN 50022).
www.deif.com
www.deif.com
3 transmission ratios
Looking for:
Required active performance of the summation current transformer: Current meter Performance recorder Measurement conductor loss consumption Po summation ct Interim result 1.5 VA 7.0 VA 1.5 VA 4.0 VA 14.0 VA
The individual transformer must provide its VA share from this 14.0 VA corresponding to its ratio to the total transmission. Consideration must also be given to the respective power loss between the main transformer and the summation transformer plus other possible losses. 1000 14.0 = 5.83 VA + additional possible losses 2400 800 14.0 = 4.67 VA + additional possible losses 2400 600 14.0 = 3.50 VA + additional possible losses 2400
The VA values of the main transformers are to be rounded up to the corresponding VA values in our charts. The ratio of the primary current of a main transformer to the sum of the primary currents of all main current transformers the ratio must not exceed 1:8.
important indication to the power measuring Too many rising deviation can prevent the measuring transformer acting as a current transformer from fulfilling its protective function with regard to the connected measuring units, as in normal operation its functions is well below its saturation limit, and in the event of over currents, the saturation limit is reached considerably later and takes the function almost as a protection current transformer. If there is too much of a decrease, the measuring transformer, as a result of the continuous excess demands will reach the saturation limit too soon and indirectly function as a switch, rendering a measuring impossible.
www.deif.com
KSu 2
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
Type
1+1
2
5 7.0(2.24)
5+5
3 3 3
3 3 3
1 27.0(5 .00)
K AK
9 0.0(3.54)
K AL BL CL
9 3.5(3.68)
BK CK
2 9.8(1.17) 1 9.4(0.76)
5 0.0(1.96) 8 0.0(3.15)
Connection example for different ratios AK-AL BK-BL CK-CL = = = 1000/5 800/5 600/5
KSu 3
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3
Type 3
5+5+5
5 7.0(2.24)
1 27.0(5 .00)
K AK
9 0.0(3.54)
K AL BL CL
9 3.5(3.68)
BK CK
2 9.8(1.17) 1 9.4(0.76)
5 0.0(1.96) 8 0.0(3.15)
Connection example for different ratios AK-AL BK-BL CK-CL = = = 1000/5 800/5 600/5
www.deif.com
SuSK 3
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3
Type 3
5+5+5
6 5 .0 (2 .5 5 )
6 0 .0 (2 .3 6 )
AL BL
EL FL GL HL
1 40 .0 (5 .5 1 )
1 36 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
www.deif.com
SuSK 4
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3
Type
5+5+5+5
3 3 3 3 3
3 3 3
6 5 .0 (2 .5 5)
6 0 .0 (2 .3 6)
AL BL
EL FL GL HL
1 40 .0 (5 .5 1 )
1 36 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
8
www.deif.com
SuSK 5
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3
Type 5
5+5+5+5+5
6 5 .0 (2 .5 5)
6 0 .0 (2 .3 6)
AL BL
EL FL GL HL
1 4 0 .0 (5 .5 1 )
1 3 6 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
www.deif.com
SuSK 6
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3
Type 6
5+5+5+5+5+5
6 5 .0 (2 .5 5 )
6 0 .0 (2 .3 6 )
AL BL
EL FL GL HL
1 40 .0 (5 .5 1 )
1 36 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
10
www.deif.com
SuSK 7
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3
Type 7
5+5+5+5+5+5+5
6 5 .0 (2 .5 5 )
6 0 .0 (2 .3 6 )
AL BL
EL FL GL HL
1 4 0 .0 (5 .5 1 )
1 36 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
www.deif.com
11
SuSK 8
5a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
1a
Accuracy class 1 0.5 Art.-no. Art.-no.
3 3 3 3 3 3 3 3 3 3 3 3 3
Type 8
5+5+5+5+5+5+5+5
6 5 .0 (2 .5 5)
6 0 .0 (2 .3 6)
AL BL
EL FL GL HL
1 4 0 .0 (5 .5 1 )
1 3 6 .5 (5 .3 7 )
CL DL
5 4 .0 (2 .1 2 )
9 5 .0 (3 .7 4 ) 1 2 2 .0 (4.80 ) 1 5 6 .0 (6.14 )
Weight Security factor DIN rail mounting Sealed shutter Primary Sealed shutter Primary
12
www.deif.com
current transformers
Test certificate On request, we can provide you with a test certificate for a specific current transformer along with the CT. Please inform us when placing your order. Sealed shutter On request, we can supply a transparent plastic cover. The cover seals the connections on the CT in a way that leaves the type label visible. Please check availability on each individual data sheet.
excitation curve On request, we can provide you with an excitation curve for a specific current transformer along with the CT. Please inform us when placing your order. optional frequency Frequency range for a standard CT is 50-60Hz. On request, we can provide you with a frequency range from 16 2/3 400Hz. Please inform us when placing your order. cast resin Cast resin is standard for all CTs with a nominal current >4,000A. On request, all CTs with a nominal current <4,000A can be produced with cast resin. Please inform us when placing your order. The min. and max. weight specification for each type refers to standard versions. The specification is different if cast resin is ordered for CTs <4,000A. mounting Foot angle for screw mounting and busbar mounting screws with isolating protection caps are supplied along with the CT. DIN-rail mounting for tubes, plug-ins and protection transformers is available on request for certain CT types. Please check availability on each individual data sheet.
www.deif.com
13