Bondstrand
Bondstrand
Bondstrand
Description
Bondstrand Taper-Taper fittings & flanges are glassfiber reinforced filament-wound epoxy
pipe fittings in diameters 50 through 1000 mm (2-40 inch) designed to be used with
Bondstrand pipes. Pipe is standard with integral Taper-Taper spigot and socket ends for
adhesive bonding or with integral Key-Lock male and female ends for mechanical joining.
Fittings are filament-wound with integral taper socket ends. Pipes and fittings are
available in several pressure classes from 10 bar upwards.
For intended services and performance capabilities refer to product data sheet FP 452 and
FP 158 pertaining to Bondstrand Series 2400 and 3400 pipe data.
Dimensional data for Taper-Taper adhesive bonded fittings are contained in individual
dimensional sheets per pressure class:
FP No.
Fitting
Pipe System
Pressure
549-10
549-12
549-14
549-16
549-20
549-25
549-32
549-40
549-50
T-10
T-12
T-14
T-16
T-20
T-25
T-32
T-40
T-50
10 bar
12 bar
14 bar
16 bar
20 bar
25 bar
32 bar
40 bar
50 bar
Dimensions of the
taper-taper joint
mm
50
80
100
150
200
250
300
350
400
450
500
600
700
Quantity of Adhesive
inch
2
3
4
6
8
10
12
14
16
18
20
24
28
Taper
Angle
degrees
1.75
1.75
1.75
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
2.50
1.75
Nominal
Pipe Size
mm
50
80
100
150
200
250
300
350
400
450
500
600
700
Insertion
Depth
Ds
mm
50
50
50
80
80
110
140
140
170
170
200
230
290
Adhesive
Kit Size
inch
2
3
4
6
8
10
12
14
16
18
20
24
28
cm3
89
89
89
89
177
177
177
177
177
177
177
177
177
Spigot
Nose
Thickness
t
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
2.0
2.5
5.5
Spigot
Diameter
at Nose
mm
55.2
83.8
107.2
161.0
210.8
264.9
315.7
347.4
396.7
436.8
486.1
583.6
711.0
Minimum number of
adhesive kits per joint
fluid
ounce
3
3
3
3
6
6
6
6
6
6
6
6
6
Note:
Adhesive kits should never be split. If remainder is not used for other joints made at the
same time, the surplus must be discarded.
nr.
0.2
0.2
0.4
0.8
1.0
1.0
2.0
2.0
3.0
3.0
3.0
5.0
7.0
Elbows 90
Elbows 45
Elbows 221/2
Filament-wound 221/2 elbows with integral Taper-Taper adhesive bonded socket ends
Nominal Pipe Size
Laying
Overall
Insertion
Weight
Length
Length
Depth
L
OL
Ds
mm
inch
mm
mm
mm
kg
50
2
29
79
50
0.4
80
3
37
87
50
0.6
100
4
43
93
50
0.9
150
6
60
140
80
2.8
200
8
76
156
80
5.1
250
10
68
178
110
9.7
300
12
77
217
140
15.5
350
14
71
211
140
21.0
400
16
85
255
170
24.0
450
18
106
276
170
39.0
500
20
116
316
200
56.0
600
24
136
366
230
93.0
700
28
157
447
290
173.0
Tees
Reducing Tees
Filament-wound reducing tees with integral Taper-Taper adhesive bonded socket ends
Nominal Pipe Size
Laying Overall Insertion Laying Overall Insertion Weight
Length Length Depth Length Length Depth
half
half
run
branch branch branch
run x run x branch
run
run
L1
OL1
Ds1
L2
OL2
Ds2
mm
inch
mm
mm
mm
mm
mm
mm
kg
80x80x50
3x3x2
96
146
50
86
136
50
2.7
100x100x50
4x4x2
115
165
50
99
149
50
3.8
100x100x80
4x4x3
115
165
50
108
158
50
4.0
150x150x50
6x6x2
153
233
80
124
174
50
10.9
150x150x80
6x6x3
153
233
80
134
184
50
12.0
150x150x100 6x6x4
153
233
80
140
190
50
12.2
200x200x80
8x8x3
188
268
80
159
209
50
16.0
200x200x100 8x8x4
188
268
80
172
222
50
16.7
200x200x150 8x8x6
188
268
80
178
258
80
17.9
250x250x100 10x10x4
226
336
110
194
244
50
29.0
250x250x150 10x10x6
226
336
110
204
284
80
32.0
250x250x200 10x10x8
226
336
110
213
293
80
34.0
300x300x100 12x12x4
264
404
140
216
266
50
43.0
300x300x150 12x12x6
264
404
140
229
309
80
44.0
300x300x200 12x12x8
264
404
140
239
319
80
45.0
300x300x250 12x12x10 264
404
140
251
361
110
51.0
350x350x150 14x14x6
272
412
140
254
334
80
42.0
350x350x200 14x14x8
272
412
140
264
344
80
54.0
350x350x250 14x14x10 272
412
140
277
387
110
62.0
350x350x300 14x14x12 272
412
140
289
429
140
66.0
400x400x150 16x16x6
295
465
170
274
354
80
55.0
400x400x200 16x16x8
295
465
170
283
363
80
56.0
400x400x250 16x16x10 295
465
170
293
403
110
63.0
400x400x300 16x16x12 295
465
170
305
445
140
67.0
400x400x350 16x16x14 295
465
170
315
455
140
71.0
450x450x200 18x18x8
339
509
170
316
396
80
100.0
450x450x250 18x18x10 339
509
170
329
439
110
104.0
450x450x300 18x18x12 339
509
170
329
469
140
107.0
450x450x350 18x18x14 339
509
170
330
470
140
137.0
450x450x400 18x18x16 339
509
170
330
500
170
143.0
500x500x250 20x20x10 370
570
200
355
465
110
180.0
500x500x300 20x20x12 370
570
200
355
495
140
186.0
500x500x350 20x20x14 370
570
200
356
496
140
188.0
500x500x400 20x20x16 370
570
200
356
526
170
195.0
500x500x450 20x20x18 370
570
200
365
535
170
200.0
600x600x300 24x24x12 434
664
230
405
545
140
211.0
600x600x350 24x24x14 434
664
230
406
546
140
281.0
600x600x400 24x24x16 434
664
230
406
576
170
220.0
600x600x450 24x24x18 434
664
230
428
598
170
239.0
600x600x500 24x24x20 434
664
230
428
628
200
279.0
700x700x400 28x28x16 497
787
290
483
653
170
520.0
700x700x450 28x28x18 497
787
290
483
653
170
525.0
700x700x500 28x28x20 497
787
290
491
691
200
539.0
700x700x600 28x28x24 497
787
290
491
721
230
560.0
Concentric Reducers
Couplings
Nipples
Filament-wound pipe nipples with integral Taper-Taper adhesive bonded spigot ends
Nominal Pipe Size
Laying
gap
Insertion
Weight
Lenght
Depth
L
Ds
mm
inch
mm
mm
mm
kg
50
2
125
25
50
0.1
80
3
125
25
50
0.1
100
4
125
25
50
0.1
150
6
185
25
80
0.5
200
8
190
30
80
0.7
250
10
250
30
110
1.4
300
12
320
40
140
2.5
350
14
320
40
140
3.1
400
16
380
40
170
4.8
450
18
400
60
170
5.8
500
20
460
60
200
8.7
600
24
520
60
230
13.9
700
28
640
60
290
27.0
Heavy-Duty Flanges
***
Heavy Duty Flanges are standard available in drillings according to ANSI and ISO
(DIN).
Full-face elastomeric gaskets may be used, suitable for the service pressure, service
temperature and fluid. Shore A durometer hardness of 60 5 is recommended and a
thickness of 3 mm.
Compressed fibre gaskets, 3 mm thick, compatible with the pressure, temperature
and medium, may also be used. The mechanical properties should be in accordance
with DIN 3754 (IT 400) or equal.
For maximum bolt torque refer to the appropriate Bondstrand literature. Please be
aware that excessive torque may result in flange failure and, therefore a torquewrench is required.
Stub-end Flanges
***
****
Stub-End Flange Rings are standard available in drillings according to ANSI and ISO
(DIN).
Stub-End Flanges are available with and without O-ring groove in the face.
Up to 10 bar stub-ends without grooves can be used with flat elastomeric or
compressed fibre gaskets.
For pressures 12 bar and above suitable O-ring seals should be used, available on
request.
Make sure that the O-ring grooved stub-end is compatible with its counter flange,
e.g. use a stub-end without groove or another flat surface flange as counter flange.
Maximum bolt-torque for use with O-rings seals may be calculated based on
pressure, size and number of bolts. If using flat face gaskets (maximum pressure 10
bar) refer to the appropriate Bondstrand literature for hubbed flanges.
Key-lock Adapters
& Couplings
Field Testing
Pipe system is designed for field testing with water at 150% of rated pressure.
Surge Pressure
Conversions
1 psi
1 bar
1 MPa
1 inch
1 Btu.in/ft2hF
C
Important Notice
= 6895 Pa
= 0.07031 kg/cm2
= 105Pa
= 14.5 psi
= 1 N/mm2
= 145 psi
= 25.4 mm
= 0.1442 W/mK
= 5/9 (F-32)
= 1.02 kg/cm2
= 10.2 kg/cm2
This product literature and the recommendations for usage it contains are based on test data
reasonably believed to be reliable. It is intended that this literature be used by personnel
having specialised training in accordance with currently accepted industry practice and
normal operating conditions. Variation in environment, changes in operating procedures, or
extrapolation of data may cause unsatisfactory results. We recommend that your engineers
verify the suitability of this product for your intended application. Since we have no control
over the conditions of service, we expressly disclaim responsibility for the results obtained
or for any consequential or incidental damages of any kind incurred.
Fiberglass-Composite
Pipe Group
Headquarters
P.O. Box 801148
Houston TX 77280
U.S.A.
Phone: (+1) 713 690 7777
Fax: (+1) 713 690 2842
Internet:www.ameron.com
email:marcom@ameronfpd.com
Fiberglass-Composite
Pipe Group
The Americas
P.O. Box 878
Burkburnett, Texas 76364
U.S.A.
Phone: (+1) 940 569 1471
Fax: (+1) 940 569 2764
Fiberglass-Composite
Pipe Group
Europe
Ameron B.V.
P.O. Box 6
4190 CA Geldermalsen
The Netherlands
Phone: (+31) 345 587 587
Fax: (+31) 345 587 561
internet: www.ameron-fpg.nl
email: info@ameron-fpg.n
Fiberglass-Composite
Pipe Group
Asia
Ameron (Pte) Ltd
No. 7A, Tuas Avenue 3
Jurong
Singapore 639407
Phone: (+65) 6861 6118
Fax: (+65) 6862 1302/6861 7834
internet: www.ameron.com.sg
email: info@ameron.com.sg