Lsi Ascorel Brochure 1
Lsi Ascorel Brochure 1
Lsi Ascorel Brochure 1
MC602
MC602
SAFETY SYSTEM FOR CRANES The MC602 is an anticollision and zoning system designed to prevent cranes from ying over forbidden zones or running into one another when multiple cranes are present on one site.
www.towercraneanticollision.com
JIB ORIENTATION HOOK HEIGHT DISTANCE FROM STARTING POINT (only if crane on rails)
MAIN FUNCTIONALITIES
CRANE ANTICOLLISION MONITORING ZONING MONITORING GRAPHIC DISPLAY OF FORBIDDEN AREAS AND INTERFERING CRANES IN REAL TIME CALIBRATION DONE DIRECTLY ON HEAD UNIT (NO EXTRA TOOL NECESSARY) SECONDARY DISPLAY AVAILABLE FOR CONTROL AND USE OF SYSTEM FROM THE BOTTOM OF THE CRANE COMMUNICATION BETWEEN SEVERAL CRANES BY WIRE OR RADIO TRANSMISSION BLACK BOX AVAILABLE TO RECORD CRITICAL EVENTS OVERRIDE (BYPASS) DETECTION LOAD, WIND SPEED, HOOK HEIGHT AND MOMENT STATUS AVAILABLE IN REAL TIME MANAGE UP TO 16 INTERFERING CRANES SUPERVISOR SOFTWARE AVAILABLE TO REMOTELY MONITOR CRANES IN REAL TIME OVER THE INTERNET
MC602
www.towercraneanticollision.com
COMPUTER
RADIO LINK
HEAD UNIT
TRAVEL SENSOR
BYPASS
AVAILABLE OPTIONS
SUPERVISOR SOFTWARE
The SUPERVISOR software enable remote monitoring of your cranes over the internet. Each MC602 installed on site communicates via radio with a local computer. That computer is connected to the internet and acts as a server so you can get access to your cranes information from anywhere in the world in real time.
INTERNET
ON WORK SITE Computer equipped with radio transmitter and connected to the internet acts as server
ANYWHERE IN THE WORLD Computers that connect to the internet have secure access to cranes information in real time.
www.towercraneanticollision.com
PROACTIVE SAFETY
TECHNICAL SPECIFICATIONS
MC602
POWER Voltage: 24 Vdc Consumption: less than 1 A WEIGHT OF UNIT 13.23 lb. (6 kg) DIMENSIONS 11.81 x 11.81 x 4.33in. (300 x 300 x 110mm) DISPLAY AND KEYBOARD 320 x 240 x 5.7 in. DEGREE OF PROTECTION IP 65 NUMBER OF CRANES MONITORED up to 16, withouot incidence on reaction time RADIO LINK Choice of 3 frequencies: 870, 458, 433 Mhz FIXED OBSTACLES 10 zones of 16 points each INTER CRANES COMMUNICATION cable or radio EXTERNAL SUPPLY BLOCK 380 to 500 VAC, 50 or 60 Hz ENVIRONMENTAL CHARACTERISTICS Operating temperature: -4F to 140F (-20C to 60C) Storage temperature: -22F to 158F (-30C to 70C) SYSTEM INTERNAL CONNECTIONS CAN bus
INSTALLATION
CONTACT US FOR MORE INFORMATION Direct Phone: +1.281.664.1330 Middle East: +971.6.557.8314 sales@loadsystems.com www.loadsystems.com
www.towercraneanticollision.com