Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

CSK Omron Counters Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Electromagnetic Counter

CSK
Miniature, Electromagnetic Totalizing Counter
High-speed response (up to 35 cps) Locking mechanism for errorless operation Unique mechanism eliminates digit displacement during resets UL listed model also available (File No. E67871)

Ordering Information
Numbering of digits

Mounting method Terminal Locking mechanism


No Yes Non-resetting No No Yes Non-resetting No

Surface mounting Wire-wrap terminals CSK4 CSK4-K --CSK6 CSK6-K --Lead wires

Flush mounting Wire-wrap terminals CSK4-Y CSK4-YK CSK4-YL CSK6-Y CSK6-YK CSK6-YL Lead wires

4 digits

Resetting system Manual reset

CSK4-W CSK4-KW CSK4-LW CSK6-W CSK6-KW CSK6-LW

CSK4-YW CSK4-YKW CSK4-YLW CSK6-YW CSK6-YKW CSK6-YLW

6 digits

Manual reset

Note: 1. When placing your order, specify the desired supply voltage listed in Specifications and a UL listed model if required, in addition to the model number. 2. If a UL listed model is required, specify this in your order in addition to the desired model number.

Specifications
Ratings
Supply voltage (see note) Operating voltage range Power consumption ON time rating Counting speed Character height 100, 200 VAC, 50/60 Hz 6, 12, 24, 48, 100 VDC 85% to 110% of rated voltage AC: approx. 3 VA DC: approx. 3.5 W Continuous rating AC input: 15 cps (contact) (ON/OFF ratio: 1:1) DC input: 20 cps (contact) (ON/OFF ratio: 1:1) 4 mm

Note: The DC models have no polarity.

http://www.ia.omron.com/

(c)Copyright OMRON Corporation 2008 All Rights Reserved.

CSK
Characteristics
Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Life expectancy Approved standards (see note) Weight 100 M min. (at 500 VDC) 1,500 VAC, 50/60 Hz for 1 minute Destruction: 16.7 Hz, 4 mm double amplitude Malfunction: 10 to 55 Hz, 0.5 mm double amplitude Destruction: 300 m/sec2 (approx. 30G) Malfunction: 50 m/sec2 (approx. 5G) Operating: 10C to 45C Storage: 25C to 65C 45% to 85% 50,000,000 counts UL508 4-digit model: approx. 100 g 6-digit model: approx. 110 g

Note: These standards apply to the -US models only.

Dimensions
CSK4-W/KW/LW
*

CSK4/K
@1 13.15 6.8 6.8 13.15

Mounting Holes CSK4-W/KW/LW


6 dia. 12.60.2

Reset button** 32.6 22.6

2 4.5

80 max. 11.3 20 7 M3.5 11.3 (11.3) 10

4 dia.

CSK4/K
Two, 6.5 dia. 13.60.2 70.2 4 dia.

3.5 dia. Locking mechanism** 10

(11.3) M3.5

* Lead wire length: approx. 250 ** CSK4-L and CSK4-LW are not provided with reset button nor locking mechanism. CSK4 and CSK4-W are not provided with locking mechanism.

CSK6-W/KW/LW
* 3 dia. 21.8 13.15 Reset button** 44.1 22.6 2 80 max. 4.5 3.5 dia. Locking mechanism** 10 7 M3.5 11.3 (11.3)

CSK6/K
3 dia. 21.8 6.8 @1 6.8 13.15

CSK6-W/KW/LW
18.40.2 70.2 21.80.2 4 dia. 3.5 dia. 6 dia.

CSK6/K
20 7 M3.5 11.3 (11.3) Two, 6.5 dia. 13.60.2 70.2 3.5 dia. 21.80.2 4 dia.

* Lead wire length: approx. 250 ** CSK6-L and CSK6-LW are not provided with reset button nor locking mechanism. CSK6 and CSK6-W are not provided with locking mechanism.

10

CSK4-YW/YKW/YLW
3.5 dia. 33 3.15 * 36.2

CSK4-Y/YK/YL

CSK4-YW/YKW/YLW CSK4-Y/YK/YL
281 Two, M3 (or two, 3.5 dia.) 381 502

36.2

Reset button**

Locking mechanism** 15 max. 23 500.1 60 62.3 26 3 10 20 7 26

31 Two, 3.5 dia.

* Lead wire length: approx. 250 ** CSK4-YL and CSK4-YLW are not provided with reset button nor locking mechanism CSK4-Y and CSK4-YW are not provided with locking mechanism.

http://www.ia.omron.com/

(c)Copyright OMRON Corporation 2008 All Rights Reserved.

CSK
CSK6-YW/YKW/YLW
3.5 dia. * Two, M3 (or two, 3.5 dia.) 44.5 12.9 47 8.9 47 281 491 630.2 Reset button** Locking mechanism** Two, 3.5 dia. 15 max. 31 630.1 72 23 3 10 62.3 7 26 20 26

CSK6-Y/YK/YL

CSK6-YW/YKW/YLW CSK6-Y/YK/YL

* Lead wire length: approx. 250 ** CSK6-YL and CSK6-YLW are not provided with reset button nor locking mechanism. CSK6-Y and CSK6-YW are not provided with locking mechanism.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.

http://www.ia.omron.com/

(c)Copyright OMRON Corporation 2008 All Rights Reserved.

Read and Understand This Catalog


Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.

Warranty and Limitations of Liability


WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specied) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certication documents identifying ratings and limitations of use that apply to the products. This information by itself is not suf cient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Disclaimers
CHANGE IN SPECIFICATIONS
Product specications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when signicant construction changes are made. However, some specications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to x or establish key specications for your application on your request. Please consult with your OMRON representative at any time to con rm actual specications of purchased product.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS


The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.

PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRONs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.

COPYRIGHT AND COPY PERMISSION


This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.

2008. 1

OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/

In the interest of product improvement, specifications are subject to change without notice.

(c)Copyright OMRON Corporation 2008 All Rights Reserved.