Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

HT 350

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

HE71x SERIES Operation manual for Dew point & Wet bulb thermo-hygrometer

HE71x series (including HE710 HE715 Dew point & Wet bulb thermo-hygrometer,they are Comprehensive temperature and humidity measuring instruments which can measure the RH, air temperature,temperature for DEWP as well as temperature for WBT ,it has the advanced functions which including automatically turn off, backlight,check for MAX and MIN value. HE71x series thermo-hygrometer designed by HUATO company,and also enjoy the development and production of this model ,it adopts Switzerland digital temperature humidity integration sensor.The ergonomic design,accuracy measurement,convenient operation,suitable for all kinds of professional environmental measurement for air temperature and humidity .

1.1 Production Features z z z z z


The fixed value for checking the MAX and MIN recording data. LCD display temperature and humidity simultaneously. One switching button for //K. Adopt Switzerland digital temperature humidity integration sensor. Special design , elegant appearance,and ergonomic design can protect the sensor well.

1.2 Applications
Agricultural research fields,food industry,medical industry,chemical industry,weather station and laboratory etc.

1.3 Performance Parameter


Measurement Range Temperature-20~+70(- 4~+158) Humidity0~100%RH Temperature for Dew Point DEWP-21.6~70.0(-6.9~158) Temperature for Wet Bulb WBT -78.7~70.0(-99.9~158) RT0.1/ RH0.1%RH Temperature for DEWP0.1/ Temperature for WBT0.1/

Resolution Accuracy Record Volume Display Response Interval Operation Environment LCD Display Size Weight Power Supply Power Consumption Index Accessories Optional Accessories

Temperature0.5HE710/ 0.3HE715 humidity3%RHHE710 / 2%RHHE715 99 Groups LCD double display,display temperature and humidity simultaneously. 1.5s 0-80%RH, 0-50 54 x44 mm 275(L) x 96(W) x 44mm(T) 290g 9V square battery 2.5mABacklight on/ 1mABacklight off Battery,operation manual,tool box Tripod, spare battery

--------P.2--------

1.4 Dew point/wet bulb/temperature and humidity quick start

LCD Display CFKSwitching button for //K temperature SETUPEnter into the model of setup ,and set temperature and humidity value. ON/OFF DEWPSwitching button for Backlight /temperature for DEWP/temperature for READButton for checking the recording data during normal working status HOLDHolding the fixed measuring data Status during normal working status.

MAX/MIN Maximum and minimum checking buttons MEMManual recording data checking button Model label USB port Hole for fixed frame Battery cover

--------P.3--------

1.5 LCD display instructions

This symbol shows it enters into the setup status for temperature and humidity offset. Humidity value display area. Temperature value display area. This symbol shows being the status of temperature measuring for DEWP. This symbol shows being the maximum temperature and humidity data checking status. This symbol shows being the minimum temperature and humidity data checking status. This symbol shows being the status of temperature measuring for WBT. This symbol shows beginning to enter into the manual-recording data status. Battery status indication,if it is full,it indicates the power is enough,and if it is empty,it indicates the power is not enough,please replace it with new batteries. Capacity display area for auto-recording and manual-recording data. Capacity display area for auto-recording and manual-recording data. Year/month-date/clock alternate display area. Temperature symbol display area. Humidity symbol display area.

--------P.4--------

1.6 Instructions for buttons function Buttons Introduction for buttons operation
ON/OFF : in the status of off ,click to turn on the instrument,and in the status of on,click to turn off the instrument. //K switching button: click it to switch the //K temperature. Button for setup mode:click to set calibration for temperature deviation ,click

again to set calibration for temperature deviation,finally click to save the settings and exit the current mode. Under setup mode,it has the setting functions as follows: 1calibration for temperature deviation: click up values,when click up click down down to change the

once,it indicates the temperature will decrease 0.1, when

once,it indicates the temperature will increase 0.1. again and then click up once,it indicates the humidity will down

2calibration for humidity deviation: click to change the values,when click up decrease 0.1, when click down Click again

once,it indicates the humidity will increase 0.1.

to save the settings and exit the current mode. again ,it will show DEL DATA XXin the left corner

3SETUP DEL MEM: click of LCD,click up data,click down data.Click again

,it will show DEL DATA 00,it indicates to delete the log ,it will showDEL DATA XX,it indicates don't delete the log to save the settings and exit the current mode.

Switching button for air temperature/backlight/temperature for DEWP/temperature for WBT: 1The backlight is closed during normal air temperature status. 2 Click to open the backlight, after 15 seconds the backlight will close automatically. 3 Click again to show DEWP, it shows the measurement temperature value for DEWP. 4 Click again to show WBT,it shows the measurement temperature value for WBT. 5 Finally click to switch to the normal status for air temperature. 1Direction button during the setup mode. 2Manual data checking button during the normal working mode :click to check the log

--------P.5--------

data,it shows READ DATA and data groups,click up

and down

to change

the data groups, and press long for 3 seconds to the disappearance of READ DATA and data groups ,exit the current mode for checking the log data. MAX/MIN :click to show MAX ,it enters into the MAX measurnent fixed MAX nor MIN,it shows the current measurement value. Button for clock symbol the clock symbol doesn't flicker in normal status,and click it status,and click

again to show MIN ,it enters into MIN measurement fixed status. When it neither shows

once,the clock symbol will flicker and click again it will get back to the normal status. 1 Direction button during the setup mode. 2Button for manual-recording data during normal working status: click it once,it will store the current measuring data,total in 99(capacity).The manual recording data and data number will disappear automatically after 5 seconds.

HUATO ELECTRONIC (SHENZHEN) CO., LTD.


Address: F3 of Building 1, Taohuayuan Technological Innovation Zone, Xixiang Street, Baoan District, Shenzhen, China. After-sales service hotline0086-755-29977880 Fax0086-755-29748856 (V1.0 B924) Websitehttp://www.huato.cn

--------P.6--------

You might also like