FI Series Pumps
GPM: 40 - 4,000 Head (ft): 10 - 380 HP: 1/3 - 200 SIZES: 1-1/4 10
Cast iron casing with integrally cast feet enables pump to be bolted to base for sturdier installation. Allows for back pull without disturbing piping. Low-cost, replaceable wear rings protect casing during normal operation. Standard ceramic seals promote product flexibility, enabling basic
product offering to meet a wide range of application requirements. Dry shaft design ensures shaft is never exposed to system fluid, eliminates need for expensive corrosionresistant shaft, and simplifies sleeve and seal removal/reassembly. Rear pullout design allows pump to be serviced without disturbing system piping.
CI Series Pumps
End Suction Close Coupled Foot Mounted
GPM: 40 - 2,200 Head (ft): 10 - 380 HP: 1/3 - 50 SIZES: 1-1/4 8
Flush seal line taps allow for installation of filter to protect seal from particles present in open systems. 1/4 NPT pressure tapping on suction and discharge connections. Standard ceramic seals promote product flexibility, enabling basic product offering to meet a wide range of application requirements. Low-cost, replaceable wear rings protect casing during normal operation.
Top centerline discharge design simplifies piping layouts, reduces piping strain, and makes pump selfventing. Cast iron casing with integrally cast feet enables pump to be bolted to a housekeeping pad for sturdier installation and still allow back pullout without disturbing the piping. Dry shaft design ensures shaft is never exposed to system fluid,
eliminates need for expensive corrosion-resistant shaft, and simplifies sleeve and seal removal/ reassembly. Easy-to-replace slip-on shaft sleeve facilitates seal maintenance in the field and lowers long-term maintenance costs. Rear pullout design allows pump to be serviced without disturbing system piping.
NOTE: All pumps are also available with 50Hz or 60Hz motors
-3-
KS Series Pumps
Vertical In-Line Split Coupled
GPM: 40 - 12,000 Head (ft): 10 - 380 HP: 3/4 - 600 SIZES: 1-1/2 14
Designed for optimum performance and ease of installation and maintenance. Ideal for HVAC and industrial applications. The split coupler design permits changing of the seal without disturbing the motor or the piping. The axial load is hydraulically balanced to increase bearing life, better
pump efficiencies, and lower NPSH requirements. The recirculating line flushes seal faces and extends seal life. Optimum pump efficiency is achieved by close running impeller to casing clearances.
KV Series Pumps
Vertical In-Line Close Coupled
GPM: 40 - 2,400 Head (ft): 10 - 380 HP: 3/4 - 100 SIZES: 1-1/2 8
Designed for optimum performance and ease of installation and maintenance. Ideal for HVAC and industrial applications. Space saving design that doesnt require isolation pads. Closed coupled design provides improved alignment and increased seal life.
The axial load is hydraulically balanced to increase bearing life, better pump efficiencies, and lower NPSH requirements. The recirculating line flushes seal faces and extends seal life. Optimum pump efficiency is achieved by close running impeller to casing clearances.
NOTE: All pumps are also available with 50Hz or 60Hz motors
-4-
GT Series Pumps
Horizontal Split Case
GPM: 2,000 - 18,000 Head (ft): 20 - 430 HP: 30 - 1,500 SIZES: 10 18
GT Series Single-Stage, Double Suction Horizontal Split Case Pumps provide the ultimate in reliability and ease of installation Cast Iron Pump Casing High-efficiency Double Suction Bronze or Stainless Steel Impeller Carbon Steel or Stainless Steel Shaft Bronze or Stainless Steel Shaft Sleeve Mechanical Seal Handles a wide range of applications with superior longevity
TA Series Pumps
Horizontal Split Case
GPM: 100 - 5,500 Head (ft): 15 - 390 HP: 1 - 400 SIZES: 2 12
Impeller is designed to assure minimum NPSH requirements and maximum pump efficiency. Mechanical seal option reduces shaft length and minimizes shaft deflection, thereby increasing both seal and bearing life. Double suction design virtually eliminates axial thrust and reduces bearing loading, promoting maximum bearing life.
Rugged, heavy-duty casing design allows higher working pressures, provides greater structural integrity, and reduces the risk of distortion.
Top half of casing is easily removed for easy service of the rotating unit without disturbing piping.
TC Series Pumps
Vertical Split Case
GPM: 100 - 11,000 Head (ft): 15 - 500 HP: 1 - 400 SIZES: 2 12
TC Series Single-Stage, Double Suction Vertical Split Case Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning, pressure boosting, cooling water transfer, and water supply applications. Quiet, dependable and proven performance: thats the TC Series.
NOTE: All pumps are also available with 50Hz or 60Hz motors
-5-
TS Series Pumps
Vertical Split Case
GPM: 100 - 11,000 Head (ft): 15 - 500 HP: 1 - 400 SIZES: 2 12
VT Series Pumps
Vertical Turbine
GPM: 60 - 7,500 Head (ft): 10 - Several thousand HP: 5 - 300 SIZES: 6 18 Bowls 4 12 Heads
Taco VT Series Vertical Turbine Pumps provide the ultimate in reliability and ease of installation. Applications include condenser water, chilled water, water transfer, pressure boosting and water supply. Quiet, dependable, with proven performance: thats the Taco VT Series of pumps. Ductile iron discharge heads TS Series Single-Stage, Double Suction Vertical Split Case Pumps provide the ultimate in reliability and ease of installation for heating, air conditioning, pressure boosting, cooling water transfer, and water supply applications. 250 psi ductile iron stuffing box with stainless steel packing glands Steel baseplate (option) Standard 416 stainless steel shafting & couplings Assembled with stainless steel bolts and impeller collets
VM Series Pumps
Vertical Multistage
GPM: 2 - 115 Head (ft): 300 - 825 HP: 1/2 25 SIZES: 1-1/4 2
Stainless steel basket strainer (option) These pumps are designed to efficiently circulate heated or chilled water in large residential and commercial hydronic or solar systems. Proven Performance Dependable, Quiet Operation Built to LastQuality design, materials and construction throughout. Rugged MotorAvailable in single and three-phase and all standard voltages. (Built-in overload protection on single-phase models.) GE and US VHS motors standard with non-reverse ratchet and space heaters High profile discharge head allows 2 piece head shaft Dual 1/4 air release ports at top of discharge flange 4 thru 10 discharge heads have matching centerlines Stainless steel bearing retainers Investment cast stainless steel impellers Epoxy lined cast iron intermediate bowls
NOTE: All pumps are also available with 50Hz or 60Hz motors
-6-
Rugged casing design has maximum operating pressure of 175 psi and a maximum operating temperature of 300F. The 1600 Series is offered in cast iron bronze-fitted or all-bronze construction. Permanently lubricated long-life bearing cartridge replaces conventional wick type bearing/bracket assembly. Single bearing cartridge services the entire product line.
One-piece enclosed impeller assures long life and higher pump efficiencies. Standard mechanical seal assures maximum flexibility. One seal fits all models; several materials available. Flexible coupler absorbs shock, vibration and misalignment that could be transmitted to the car-
tridge and motor bearings while also isolating and preventing any motor related noise or vibrations from being transmitted to the system. Resilient mounted motor ensures quiet, reliable pump operation. One bearing cartridge, one seal, and two motor frames fit all pump models, assuring superior parts flexibility.
NOTE: All pumps are also available with 50Hz or 60Hz motors
-7-
NOTE: All pumps are also available with 50Hz or 60Hz motors
-8-
Close coupled compact design is energy efficient and installs anywhere in the piping layout. Self-supporting design allows horizontal or vertical installation. Pump and sealed ball bearing motor are maintenance-free Rear pullout design and standard motor promote simple, easy service. One seal and shaft sleeve fits all models, assuring superior parts flexibility.
1900 VFD
High efficiency premium motors Allow serial communication with pump Simple selection of drives Factory preset motor rotation Robust adjustable bracket design Available in single phase and three phase models
-9-
Mini-featured AC Drives
Featuring optimal reactions times and complete scalability to match your application requirements for speed, size and protection, the complete line of Advantage products provides the flexibility and performance to meet the needs of a broad range of pumping applications.
S-Flex
Enclosed Drives
SmartDRIVE Solutions
No one knows more about controlling pumps than the people who make the pumps. Thats why our variable speed SmartDrives deliver the finest precision performance for maximum system efficiency and reduced life cycle costs. Theres a SmartDrive thats perfect for your application. From Basic to HVAC to Bypass drives, Tacos premium design standards live up to our reputation for quality & dependability in every way.
SmartDRIVE
Basic Drive
SmartDRIVE
HVAC Drive
SmartDRIVE
SP Drive
SmartDRIVE
VP Drive
DPS629
Compensated Temperature Limits: 0 to 175F (-18 to 79C). Pressure Limits: 0 - 25 PSI with an over pressure limit of 250PSI. Thermal Effect: 0.02%/F (0.036%/C) includes zero & span. Power Requirements: 13-30 VDC (2-wire). Output Signal: 4 to 20 mA. Optional 0-5, 0-10 VDC
DPS3100D
Thermal Effect: 0.125% span/32C Power Requirements: 11.9 to 45 VDC Output Signal: 4 to 20 mA
- 10 -
Five (5) Valves in one: - Shut-off valve - Flow Control Valve (Globe Style) - Non slam check valve - Flow Metering Valve - Straight Pattern Valve can be converted to a right angle pattern valve Low pressure drop (Equal to or better than any comparable valve on the market today) Suitable for 125 and 250 PSI W.P.
- 11 -
Rugged, reliable Taco Brazed Plate Heat Exchangers represent the latest technology in high-performance heat exchangers. These compact units feature copper brazed, stainless steel plates that offer a highlyefficient, low fouling transfer service. All units have male pipe thread fittings and mounting stud bolts are standard. Computerized product selection helps you choose the heat exchanger thats just right for your application. Their compact size and ease of servicing, coupled with Taco dependability, make the PF Series the perfect choice.
- 12 -
Optional removable Heads and Pall Ring baskets (recommended on open systems)
Micro Air bubble removal to 18 Microns Dirt particle removal below 30 Microns Size range from 2 to 36 / W.P. at 125, 150 or 250 PSI.
5900 FlexBalance~Plus
5900 FlexBalance
Patented 5900 FlexBalance and FlexBalance~Plus Separators act as a hydraulic bridge between the primary and secondary circuits in hydronic heating and cooling applications. The FlexBalance~Plus product line incorporates patented Pall Ring technology for deep micro-bubble and dirt removal.
Air Separators
Save money and extend the life of system pumps, piping and components with Taco ACT Series air removal units. The ACT air separator is designed and constructed to the ASME Boiler & Pressure Vessel Code, Section VIII, Division I for unfired vessels.
Stainless steel removable strainer (optional) 375F max. operating temperature Higher working pressures available.
- 13 -
CA Expansion Tanks
CAPACITY: 23 2,640 Gallons (90 -10,000 liters) DIAMETER: 20 72 HEIGHT: 29 160
Field replaceable, heavy-duty butyl full acceptance rubber bladder removes easily for inspection.*
CX Expansion Tanks
CAPACITY: 8 92 Gallons (29 -171 liters) DIAMETER: 14 24 HEIGHT: 22 60
Heavy-duty butyl rubber diaphragm expansion tank allows permanent separation of air and water.*
Heavy duty partial acceptance rubber bladder design for potable water systems.*
Molded rubber membrane allows permanent separation of air and hydronic system fluid. Field removable partial acceptance membrane design specifically developed for smaller heating and chilled water systems.*
PS Expansion Tanks
CAPACITY:15 515 Gallons (57-1893 liters) DIAMETER: 14 36 HEIGHT: 25 127
Buffer Tanks
Available in either red oxide painted or galvanized. Optional saddles for horizontal installations are available.*
CAPACITY: 50 3000 Gallons (189-11,356 liters) FLANGE SIZES: 2 12 DIAMETER: 20 84 HEIGHT: 43 145
Available in either red oxide painted or galvanized. Optional saddles for horizontal installations are available.*
Most Taco Expansion Tanks are available with either bladders or diaphragms so that water and air are permanently separated. No absorption can take place at any point during the system cycle, and you avoid the problems of waterlogged tanks, air-bound terminal units, excessive corrosion, inefficient balancing and pump cavitations. * Each of these tank model is fabricated in accordance with ASME Section VIII, Div. 1 to assure highest quality & performance.
- 14 -
Terminal Unit
Secondary Circulator
An advanced Green hydronic heating and cooling system that delivers better comfort, lower first costs, lower energy and maintenance costs, lower life cycle costs, and reduced design, start-up, and commissioning time. LoadMatch hydronic piping distribution systems utilize a primary single pipe loop joined with a decoupled secondary piping loop for all
Chiller Single Pipe Loop Primary System Pump Air Separator Dedicated Coil Circulators - Control Valves Are Not Requried
Expansion Tank
terminal units. In addition maintenance free wet rotor circulators are substituted for control valves in this decoupled secondary loop.
Dedicated Coil Circulators (Control valves not required) Terminal Unit (Chilled Beam)
The Taco LOFlo System is used in hydronic heating and cooling systems to significantly reduce the flow of water. Typically used in radiant panel (ceiling, wall or floor) and chilled beam (passive and active) applications, the technology significantly reduces pump flows and pipe sizes for reduced energy consumption and lower first costs. The LOFlo System also provides precise control of supply water to the terminal, e.g. chilled beam, and precise control of room temperatures. The basic concept of the LOFlo Mixing Block, shown here, is to
provide a complete injection mixing station in a simple factory assembled package that controls each individual zone at the lowest possible flow rate by maintaining the highest possible supply water temperatures in cooling and lowest possible supply water temperatures in heating.
- 15 -
iWorx by Taco Electronics Solutions is a powerful, webbased, easily-scalable building management, monitoring and control system designed specifically for the light commercial buildings and high-end residential markets.
Scan this QR Code with your Smart Phone to learn more about the Taco Design Suite and download this FREE software.
Taco Design Suite The Design Suite is a free collection of tools that take the time-consuming out of hydronic system design. In fact, an entire LoadMatch system can be designed in minutes from top to bottom! Load Tool What used to be a pencil-breaking task is now mouseclick easy. Here are some features of the Load Tool: Interactive tools eliminate recalculation time for changes
Hydronic System Solutions With HS2 you can: Design & compare HVAC systems Eliminate recalculation time for changes Calculate plant total loads, flows Size pipe and equipment Select and schedule equipment Reduce errors Make design changes quickly and easily LoadMatch Wizard allows modeling of systems in minutes TacoNet TacoNet is our premier product selection and specification tool for Taco equipment. Long acknowledged by the industry as the easiest software of its kind, TacoNet gives you all you need to save time and avoid errors. With TacoNet, you can: Enter all data quickly from one screen. Print submittals and schedules Save data. iWorx Selection Wizard Weve created an online iWorx Selection Wizard that lets you create and specify iWorx projects in minutes. Just answer a few simple questions about the type of job and the iWorx Selection Wizard does the rest. In minutes, you have a complete submittal package that includes wiring and air flow diagrams, bill of materials, sequence of operations, associated instruction manuals and complete job specifications.
To access the iWorx Wizard, go to www.iworxwizard.com or scan this QR Code with your Smart Phone.
iWorx is ideal for integrating forced air and hydronic systems, including geothermal and solar, and for assuring that each system communicates effectively and works smoothly together. iWorx delivers effective cost control over a buildings energy usage and HVAC equipment maintenance, plus optional BTU metering, in single locations, multi-site or multi-building installations ranging from retail stores, strip malls and restaurants to offices, apartments, schools and high-end residential. No software to buy or learn Self-configuring controllers Affordable Web-based Easy-to-install Simple-to-use Much more.
Scan with your SmartPhone to learn more.
Default values for design parameters reduce input time Drag and drop capability allows grouping of room loads to higher level terminal and systems quickly and easily Import load data directly into Hydronic System Solutions files and drawings, saving time entering loads, design parameters, etc. System Analysis Tool We designed the System Analysis Tool to save you even more time by allowing you to compare different system configurations on the fly, in the design process. Selection software for HVAC Systems Interactive tool eliminates recalculation time for changes Quickly and easily compare HVAC system operating and life cycle costs at beginning of project System selection Wizard allows quick modeling of preconfigured systems
The Taco Innovation & Development Center A few years ago, John Hazen White, Jr. set out to build the most advanced learning facility in the industry, one that would train and inspire generations. The 20,000 sq. ft., $22 million Taco Innovation and Development Center (IDC) was born and dedicated in June of 2012 to Tacos employees and the HVAC industry. State of the art classrooms The IDCs expansive classrooms are equipped with advanced multi-media hardware. From a simple PowerPoint presentation to a live streaming webinar, each classroom can deliver visual content to class attendees in the building or on the Internet. Classrooms are flexible to hold classes of any size. Green Building comfort The entire buildings comfort system was designed by some of the brightest minds in HVAC engineering using Tacos Hydronic System Solutions software. The software also helped size the IDCs pipe and equipment, calculate total loads and flows, and generate schedules. Awardwinning LoadMatch single pipe and LOFlo radiant cooling systems were installed as real-time demonstration of the energy savings, reliability, and comfort so essential for LEED Green Building certification. System components can be seen in action throughout the building, thanks to viewing panels in walls, ceilings, and floors making the IDC a hands-on living lab. The incredible mechanical room The IDCs mechanical room is a marvel of hydronic technology, featuring energy efficient boilers and chillers, variable speed pumping, geothermal and energy recovery systems, solar heating systems, all controlled by an iWorx building management system. Workhorse TC and
FloProTeam Trainers John Barba and Dave Holdorf hold training sessions on a regular basis at the IDC and on-line at FloPro Univesity.
TA pumps, vertically aligned KV and KS pumps, variable speed drives, solar pumping stations, heat exchangers, and air-dirt separators are all working displays, managing the comfort of the entire Taco facility. In this room, visitors can see how everything goes together in the most advanced hydronic facility in the industry.
Taco Catalog # 300-9.4 Supersedes: 08/13/10 Effective Date: 09/10/12 Printed in USA
Taco, Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360 Taco (Canada) Ltd., 8450 Lawson Road, Unit#3, Milton, Ontario L9T 0J8 / (905) 564-9422 / Fax (905) 564-9436 www.taco-hvac.com