Modbus-1 3e
Modbus-1 3e
Modbus-1 3e
SIO280 (8DI+8DO)
SDIDO(16DI+4DO)
LT3504(4DO)
SIO270 (8DI+2DO)
SIO235B(12AI+6DI+4DO)
LT3100(12DI/4DO)
SIO210
SDIDO(SOE)
SIO235A (4AI+4DI+2DO)
LT1050(1DI/1DO)
IS70
APPLICATIONS
Power Monitoring and Control Building Automation Process Monitoring and Control Remote Telemetry Energy Management
OVERVIEW
The SIO series of input/output modules have been designed for power scada and energy facility management system, although they have been optimized for these applications they can of course be used as general purpose I/O such as process industry automation or data acquisition system. The module is required not only to have high immunity to noise and interference, but needs to have multiple I/O types to be combined together onto the same module in order to shrink the module to a size small enough to fit within the constrained space of the panel.
PRODUCT SPECIFICATION
SIO SERIES
MODULE SELECTIONS
SIO280
SIO270
SDIDO
SDIDO(SOE)
8DI/8DO module
8DI/2DO module
16DI/4DO module
N/A
N/A
Voltage Isolation Counter Accumulator low pass filter Status Indicator LED DO channels Activity Indicator LED Form Factor Manual backup switch Contact capacity Control Modes Address max 63 8 relays Form C(no+nc)
5000 KV optical isolation YES 30 mSEC One per DI 2 relays one per relay Form A None 220VAC/2A Direct/Pulse/Restore 31 63 V TVS, PTC, photo siolation V DC24V / AC12-18V 2VA 8VA DC12V/DC24V/AC12-18V 0.5VA 3 VA AC12-18V 1.2VA 6 VA DC12V/DC24V/AC12-18V 1.2VA 6 VA 220VAC/1A Pulse 63 2 Form C +2 Form A 4 relays 4 relays
DO
RS 485
Self Diagnostic and Recovery LED Voltage Power Supply Standby Power Highest Power (Relay actvity)
Model Product Name DI Channels SOE Di input DI Voltage Isolation Accumulator low pass filter Status Indicator LED DO channels Activity Indicator LED DO Form Factor Manual backup switch Contact capacity Control Modes Address max RS485 Baud Rate Comm Indicator LED Voltage Isolation Self Diagnostic and Recovery LED Voltage Power Supply Regular Power Highest Power (Relay actvity)
LT3504 4
LT3100 12 DI/4DO
addressable relays
None None
addressable relays
12 (isolated) None
2500 V optical isolation None 30mSEC None 4 relays 4 relays one per relay Form A one per relay 220VAC/20A 220VAC/10A Direct/Restore (DIP switch) 220 VAC/15A 1 relays None None None None None
63 (set using DIP switch) 2400/9600 bps RX/TX LED indicators TVS and PTC dual protection ( Overvoltage and overcurrent ) Included (flashes once per second)
AC18V/DC24V 3 VA 3 VA
DC 12 V
AC 12 V
0.4 VA 6 VA
PRODUCT SPECIFICATION
SIO SERIES
AI
4isolated
6 isolated dry sense contact 5000V optical isolation Yes(65535 max.) 30mSEC one per DI
4 isolated
DI
Voltage isolation Accumulator Low pass filter Status indicator led Do channels Activity indicator led
2 relays
4 relays
1 relays Form A
DO
Contact form Manual backup switch Contact capacity Control modes Address max
N/A 220VAC/1A 220VAC/5A Direct/Pulse/Restore 31 (set using DIP switch) 2400 or 9600 bps (set using DIP switch) RX/TX LED indicators TVS and PTC dual protection ( Overvoltage and overcurrent ) 5000 Vrms isolation voltage Included (flashes once per second) DC 12 V/DC24V/ AC12V/AC18V 2 VA 6VA DC24V 3 VA 8VA DC 12 V/DC24V/ AC9-18V 3 VA 6VA AC12V/DC12V 1 VA 6VA 220VAC/1A 220VAC/5A Direct
RS 485
Baud rate Comm indicator led Protection (Voltage surge and overcurrent) Protection (optical isolation) Self diagnostic and recovery led Voltage
Power Supply
Control Mode
Relay ON ON
direct pulse
Each DO can be controlled using one of three modes by sending the proper command through the specific data address: (1) Restore Mode The program commands the relay to turn either on/off. When the power is restored after being interrupted, the relay will automatically go back to the last state it was in before the interruption without needing any intervention from the controlling program. (2) Direct Mode The program commands the relay directly to turn on/off. When the power is restored after being interrupted, the relay returns to its normal state. (3) Pulse Mode(Not applicable for LT3504/LT3100/LT1050/IS70) The program commands the relay to send out a pulse. The pulse duration can be set from 500 milliseconds to 2 seconds.
TMS001 Air temperature sensor 0-80C TMS003 TMS002 Water temperature sensor 0-80C
25mm
ON
command
PRODUCT SPECIFICATION
SIO SERIES
COMMUNICATIONS
Protection: - TVS and PTC for over-voltage 5.8V and over-current 100mA - Photo-isolated:5KVrms (SIO280,SDIDO,SIO235 series only) Protocol: - Modbus/RTU; 2-wire RS485 (2400 or 9600 baud); - Response time: 150msec@9600bps
Sys R1 R1
1 2 4 8 16 32 ADDRESS B ON OFF IS
RS+ RS DI+
- + DC12V
RX TX
-+
RS
C43C21 DI
3 DI
POWER
LT1050
R1 R1 Tx Rx AC
SIO210
ON OFF 1 2 4 8 16 32 ADDRESS B
ENVIRONMENT&EMC TEST
Ambient Operation: - 0 C to 70 C; 5% to 95% RH non-condensing SWC test: - meets generic standards for industrial environments; IEC 61000-4-4, 3KV; IEC 61000-4-5, 3KV
R1
o o
0-5V
C 4 3 2 1 + S
Standard
TX
RX
RS485
SIO235A
R2
NO NC C NO C 4
SIO235C
Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)
DI
3 2 1
R1 R2
Power Supply
+
ACCESSORIES
Power supply
NC
654321
0-5V
0-20 mA
A4 A9 A10 A11 A12
- Model: 24V,0.7A (NES-15-24) - Model: 12V,1.3A(NES-15-12) - Input: 85-264VAC - Over voltage: 120% - With stand voltage: 3KV(input/output) - Safety: ul60950-1 - EMC: IEC61000-4-2,3,4,5,6,8,11 - Dimension: 79X51X28mm - Protections: Short circuit/OLP/OVP
NC
NO NC
NO
R1
R2
DI
Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)
A1
A2
A3
AI
AI AI
A5 A6 A7 A8
0-20 mA
SIO235B
R3
NC C NO NC
R4
C NO
123456 RS485
+ S
Power Supply
+
AI
Thermistor input
12- 12+ 11- 11+ 10- 10- 9- 9+ C 8 7 6 5 C 4
0-5V
3 2 1 + S
Standard
TX
RX
RS485
RS232/RS485 Converter
NC
R1
C NO NC
R2
C NO C 4
DI
3 2 1
R1 R2
Power Supply
+
- Auto direction control - Status indicator: 4 LEDS - Photo-isolated: 5KVrms - Protection:TVS&PTC - Power: AC/DC 12V - RS232: 9PIN DB-9 female - Dimension: 75X60X23mm
NC C NO NC C NO
654321
10
11
12
13
14
15
16
+ -
DI
TX
RX
RS485
SDIDO
R1 R2 R3
C
R4
C
NO NC
NO NC
J3 J4 NO,NC SETTING
R1 R2 R3 R4
Power
+
system Supply
12345678
WIRING DIAGRAM
1 2 3 4 C 5 6 7 8 C
POWER SUPPLY
DI
R4 RS+ RS AC18V/ DC24V
DI
1 2 3 4 5 6
R3
ON OFF
R3
R4
C 1 2 3 4
RO
ON
DC12V
R1
NC C
SIO270
R2
NO NC C NO
RS485
+ S
1 2 4 8 16 32 ADDRESS
B IS
3 4
1 2
OFF
1 2 4 8 16 M I R ADDRESS
IS
R1 R1 R2 R2 R3 R4 R4 Rx Tx Sys
LT3504
R3
LT3100
NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO
Rx Tx Sys
R1
DI
R2
R3
R4
R5
R6
R7
R8
R2
R2
R1
R1
AC24V
RS+ -
9 - 12 C
1-8 C
DI
C 1 2 3 4 5 6 7 8
SIO280
TX(G) RX(G)
RS485
+ S
Dip 1-7 for address setting Dip 8 baud rate setting (on: 19200, off: 9600)
System
Power Supply
Modbus-1.3e.cdr