Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Modbus-1 3e

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SIO SERIES

Modbus I/O Modules

SIO280 (8DI+8DO)

SDIDO(16DI+4DO)

LT3504(4DO)

SIO270 (8DI+2DO)

SIO235C [4AI+4DI+2DO +(8 thermistor)]

SIO235B(12AI+6DI+4DO)

LT3100(12DI/4DO)

SIO210

SDIDO(SOE)

SIO235A (4AI+4DI+2DO)

LT1050(1DI/1DO)

IS70

APPLICATIONS
Power Monitoring and Control Building Automation Process Monitoring and Control Remote Telemetry Energy Management

DESIGNED FOR HIGH RELIABILITY


Typically, the cabling for electrical equipment can be wildly spread, the ideal location to affix the I/O module would be inside with the electrical panel itself. Doing so would not only reduce the labor cost of the piping and wiring, but will also reduce the costs associated with all design and commissioning and trouble shooting as well.

OVERVIEW
The SIO series of input/output modules have been designed for power scada and energy facility management system, although they have been optimized for these applications they can of course be used as general purpose I/O such as process industry automation or data acquisition system. The module is required not only to have high immunity to noise and interference, but needs to have multiple I/O types to be combined together onto the same module in order to shrink the module to a size small enough to fit within the constrained space of the panel.

DESIGNED FOR ELECTRICAL CONTROL SYSTEMS


Unlike conventional single function I/O modules (i.e. DI only module, DO only module and AI only module), the SIO series have a combination of I/O types per module. Besides, SIO also support modbus protocol over Rs485 interface port. Those features are very helpful for electrical control systems application. SIO module installed directly in the same panel as the electrical equipment, greatly reducing the cost of labor and work time

PRODUCT SPECIFICATION

SIO SERIES

MODULE SELECTIONS

Model Product Name DI Channels SOE DI input


DI

SIO280

SIO270

SDIDO

SDIDO(SOE)

8DI/8DO module

8DI/2DO module

16DI/4DO module

SOE module yes (times tamping 1 msec)

N/A

N/A dry sense contact

N/A

Voltage Isolation Counter Accumulator low pass filter Status Indicator LED DO channels Activity Indicator LED Form Factor Manual backup switch Contact capacity Control Modes Address max 63 8 relays Form C(no+nc)

5000 KV optical isolation YES 30 mSEC One per DI 2 relays one per relay Form A None 220VAC/2A Direct/Pulse/Restore 31 63 V TVS, PTC, photo siolation V DC24V / AC12-18V 2VA 8VA DC12V/DC24V/AC12-18V 0.5VA 3 VA AC12-18V 1.2VA 6 VA DC12V/DC24V/AC12-18V 1.2VA 6 VA 220VAC/1A Pulse 63 2 Form C +2 Form A 4 relays 4 relays

DO

RS 485

Baud Rate Comm Indicator LED Protection

2400 or 9600 bps (set using DIP switch)

Self Diagnostic and Recovery LED Voltage Power Supply Standby Power Highest Power (Relay actvity)

Model Product Name DI Channels SOE Di input DI Voltage Isolation Accumulator low pass filter Status Indicator LED DO channels Activity Indicator LED DO Form Factor Manual backup switch Contact capacity Control Modes Address max RS485 Baud Rate Comm Indicator LED Voltage Isolation Self Diagnostic and Recovery LED Voltage Power Supply Regular Power Highest Power (Relay actvity)

LT3504 4

LT3100 12 DI/4DO

LT1050 1DI/1DO 1 (isolated) None dry sense contact

SIO210 4DI 4 (non-isolated) None

addressable relays
None None

addressable relays
12 (isolated) None

2500 V optical isolation None 30mSEC None 4 relays 4 relays one per relay Form A one per relay 220VAC/20A 220VAC/10A Direct/Restore (DIP switch) 220 VAC/15A 1 relays None None None None None

63 (set using DIP switch) 2400/9600 bps RX/TX LED indicators TVS and PTC dual protection ( Overvoltage and overcurrent ) Included (flashes once per second)

AC18V/DC24V 1. 2VA 8VA

AC18V/DC24V 3 VA 3 VA

AC110V 220V 3.5 VA 6 VA

DC 12 V

AC 12 V

0.4 VA 6 VA

PRODUCT SPECIFICATION

SIO SERIES

MULTIFUNCTION I/O MODULE

Model Product name Ai (single end):0-5vdc Ai (differential):0-20ma

SIO235A 4AI/4DI/2DO module 4 0 N/A 0.10%

SIO235B 12AI/6DI/2DO module 4 8 N/A 0.10%

SIO235C 4AI/8T/4DI/2DO module 4 8 thermistor inputs 1 C 1sec


o

IS70 Temperature Control N/A humidity sensor(Optional) Thermistor included 0.1 oC

AI

Temperature input (thermistor) Resolution Update speed Di channels Di input

4isolated

6 isolated dry sense contact 5000V optical isolation Yes(65535 max.) 30mSEC one per DI

4 isolated

1 isolated N/A N/A N/A N/A

DI

Voltage isolation Accumulator Low pass filter Status indicator led Do channels Activity indicator led

2 relays

2 relays One for each relay Form C(no+nc)

4 relays

1 relays Form A

DO

Contact form Manual backup switch Contact capacity Control modes Address max

N/A 220VAC/1A 220VAC/5A Direct/Pulse/Restore 31 (set using DIP switch) 2400 or 9600 bps (set using DIP switch) RX/TX LED indicators TVS and PTC dual protection ( Overvoltage and overcurrent ) 5000 Vrms isolation voltage Included (flashes once per second) DC 12 V/DC24V/ AC12V/AC18V 2 VA 6VA DC24V 3 VA 8VA DC 12 V/DC24V/ AC9-18V 3 VA 6VA AC12V/DC12V 1 VA 6VA 220VAC/1A 220VAC/5A Direct

RS 485

Baud rate Comm indicator led Protection (Voltage surge and overcurrent) Protection (optical isolation) Self diagnostic and recovery led Voltage

Power Supply

Stand by power Highest power(relay actvity)

RELAY RATING TABLE DO WITH RELAY FEATURE


All the DO have built in relays, which can be connected directly to a 220 Vac source to drive a magnetic contactor, eliminating the need for an intermediate relay and a DC power supply. This not only saves on labor cost, shortens work time and saves on the equipment cost as well. The majority of the modules have NO and NC terminals to work with. For some application require to control high current load capacity, the LT series models offer high load relays and have on board manual override buttons. SIO 270 SIO 280 SDIDO SIO 235A/C SIO 235B 110VAC 3A 3A 3A 3A 3A 220VAC 2A 2A 1A 1A 1A DC24V 3A 3A 3A 3A 3A

Control Mode

Relay ON ON
direct pulse

Each DO can be controlled using one of three modes by sending the proper command through the specific data address: (1) Restore Mode The program commands the relay to turn either on/off. When the power is restored after being interrupted, the relay will automatically go back to the last state it was in before the interruption without needing any intervention from the controlling program. (2) Direct Mode The program commands the relay directly to turn on/off. When the power is restored after being interrupted, the relay returns to its normal state. (3) Pulse Mode(Not applicable for LT3504/LT3100/LT1050/IS70) The program commands the relay to send out a pulse. The pulse duration can be set from 500 milliseconds to 2 seconds.
TMS001 Air temperature sensor 0-80C TMS003 TMS002 Water temperature sensor 0-80C
25mm

ON
command

restore ON Power interrupt Power recover

TMS Temperature sensor for SIO235C&IS70


5mm NPT NPT 6mm 14mm 14mm 25.4mm

PRODUCT SPECIFICATION

SIO SERIES

COMMUNICATIONS
Protection: - TVS and PTC for over-voltage 5.8V and over-current 100mA - Photo-isolated:5KVrms (SIO280,SDIDO,SIO235 series only) Protocol: - Modbus/RTU; 2-wire RS485 (2400 or 9600 baud); - Response time: 150msec@9600bps
Sys R1 R1
1 2 4 8 16 32 ADDRESS B ON OFF IS

RS+ RS DI+

- + DC12V
RX TX

-+
RS

C43C21 DI

3 DI

POWER

LT1050
R1 R1 Tx Rx AC

DI 220V 110V COM

SIO210
ON OFF 1 2 4 8 16 32 ADDRESS B

ENVIRONMENT&EMC TEST
Ambient Operation: - 0 C to 70 C; 5% to 95% RH non-condensing SWC test: - meets generic standards for industrial environments; IEC 61000-4-4, 3KV; IEC 61000-4-5, 3KV
R1
o o

0-5V
C 4 3 2 1 + S

Standard

TX

RX

RS485

SIO235A
R2
NO NC C NO C 4

SIO235C
Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)

DI
3 2 1

R1 R2

Power Supply
+

ACCESSORIES
Power supply

NC

654321

0-5V

0-20 mA
A4 A9 A10 A11 A12

- Model: 24V,0.7A (NES-15-24) - Model: 12V,1.3A(NES-15-12) - Input: 85-264VAC - Over voltage: 120% - With stand voltage: 3KV(input/output) - Safety: ul60950-1 - EMC: IEC61000-4-2,3,4,5,6,8,11 - Dimension: 79X51X28mm - Protections: Short circuit/OLP/OVP

NC

NO NC

NO

R1

R2

DI
Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)

A1

A2

A3

AI

AI AI
A5 A6 A7 A8
0-20 mA

SIO235B

R3
NC C NO NC

R4
C NO

123456 RS485
+ S

Power Supply
+

AI
Thermistor input
12- 12+ 11- 11+ 10- 10- 9- 9+ C 8 7 6 5 C 4

0-5V
3 2 1 + S

Expansion ( SIO235C only( SIO235C

Standard

TX

RX

RS485

RS232/RS485 Converter
NC

R1
C NO NC

R2
C NO C 4

DI
3 2 1

R1 R2

Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)

Power Supply
+

- Auto direction control - Status indicator: 4 LEDS - Photo-isolated: 5KVrms - Protection:TVS&PTC - Power: AC/DC 12V - RS232: 9PIN DB-9 female - Dimension: 75X60X23mm
NC C NO NC C NO

654321

10

11

12

13

14

15

16

+ -

DI

TX

RX

RS485

SDIDO
R1 R2 R3
C

R4
C

NO NC

NO NC

J3 J4 NO,NC SETTING

R1 R2 R3 R4

Dip1-7 for address setting dip 8 baud rate setting (on:19200,off:9600)

Power
+

system Supply

12345678

WIRING DIAGRAM
1 2 3 4 C 5 6 7 8 C

system led 1:relay 2 led 2:relay 1 led 3:RX led 4:TX

POWER SUPPLY

DI
R4 RS+ RS AC18V/ DC24V

DI
1 2 3 4 5 6

R3
ON OFF

R3

R4

C 1 2 3 4
RO
ON

DC12V
R1
NC C

SIO270
R2
NO NC C NO

Dip1-5 for address setting dip 6 baud rate setting (on:19200,off:9600)

RS485
+ S

1 2 4 8 16 32 ADDRESS

B IS

3 4

1 2

OFF

1 2 4 8 16 M I R ADDRESS

IS

R1 R1 R2 R2 R3 R4 R4 Rx Tx Sys

LT3504

R3

LT3100
NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO
Rx Tx Sys

R1
DI

R2

R3

R4

R5

R6

R7

R8

R2

R2

R1

R1

AC24V

RS+ -

9 - 12 C

1-8 C
DI
C 1 2 3 4 5 6 7 8

SIO280
TX(G) RX(G)

RS485
+ S

Dip 1-7 for address setting Dip 8 baud rate setting (on: 19200, off: 9600)
System

Power Supply

DAE INSTRUMENT CORP.


5F., No. 157, Xinhu 1 st Road, Neihu District, Taipei City 114, Taiwan, R.O.C. Tel: +886-2-2793-6123 Fax: +886-2-2793-6150

Our Website: www.DAEinstrument.com

Modbus-1.3e.cdr