Pa Relays: Typical Applications
Pa Relays: Typical Applications
Pa Relays: Typical Applications
com/ac/e/
PA
ASCTB204E 201202-T
ORDERING INFORMATION
TYPES
Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
* For sockets, see page 84.
1a 5A slim power relay for
interface
PA RELAYS
Contact arrangement Nominal coil voltage Part No.
1 Form A
5V DC PA1a-5V
6V DC PA1a-6V
9V DC PA1a-9V
12V DC PA1a-12V
18V DC PA1a-18V
24V DC PA1a-24V
FEATURES
1. Slim size (width 5 mm .197 inch,
height 12.5 mm .492 inch) permits
higher density mounting
Despite the slim 5 mm width, the 20 mm
length is still compact and the 12.5 mm
prole is low. Even when a socket is
used, the height is still only 18 mm.
Suitable for high-density mounting, these
relays enable device size smaller.
RoHS compliant
2. Nominal operating power: High
sensitivity of 120mW
Enables smaller power supplies,
facilitates energy saving applications,
and contributes to device size smaller.
3. Control from low level loads to 5 A
Use of gold-clad twin contacts enables
control of low level loads down to 100 mV
100 A and up to 5 A 250 V AC and 30 V
DC.
4. Reinforced according to IEC1131-2
(TV)
5. High surge breakdown voltage
(4000 V) and high breakdown voltage
(2000 V)
Between contacts and coil of 2,000 V and
surge resistance of 4,000 V work to
prevent controller malfunctions caused by
noise and surges.
6. Outstanding vibration and shock
resistance.
Functional shock resistance: 147 m/s
2
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
2.5 mm .098 inch)
Keeps equipment from miss-operation
due to vibration and shock.
Can be used as mounted on control
panel doors.
7. Sealed construction allows
automatic washing.
8. SIL (single in line) terminal layout
9. Complies with safety standards
Complies with Japanese Electrical
Appliance and Material Safety Law, and
certied by UL, CSA, and TV.
10. Sockets are available
TYPICAL APPLICATIONS
1. Industrial equipment, ofce
equipment
2. Measuring devices and test
equipment
3. Interface relays for programmable
controllers
4. Output relays in small devices such
as timers, counters, sensors, and
temperature controllers.
Contact arrangement
1a: 1 Form A (Bifurcated)
PA 1a
Nominal coil voltage (DC)
5, 6, 9, 12, 18, 24V
Note: Certified by UL, CSA and TV
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PA
ASCTB204E 201202-T
RATING
1. Coil data
Notes: *1 Pulse drive (JIS C 5442)
*2 24V DC, 120mW type are also available, please consult us.
2. Specications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
REFERENCE DATA
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
5V DC
70%V or less of
nominal voltage *
1
(Initial)
5%V or more of
nominal voltage*
1
(Initial)
24mA 208
120mW
120%V of
nominal voltage
6V DC 20mA 300
9V DC 13.3mA 675
12V DC 10mA 1,200
18V DC 6.7mA 2,700
24V DC 7.5mA 3,200 180mW*
2
Characteristics Item Specications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A)
Contact material Au-clad AgNi type
Rating
Nominal switching capacity (resistive load) 5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load) 1,250 VA, 150 W
Max. switching voltage 250 V (AC), 110 V (DC)
Max. switching current 5 A
Nominal operating power 120 mW (5 to 18 V DC), 180 mW (24 V DC)
Min. switching capacity (Reference value)*
1
100A 100mV DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage (Initial)
Between contacts and coil*
2
4,000 V
Temperature rise (coil) (at 20C 68F)
Max. 45C
(By resistive method, nominal coil voltage applied to the coil, nominal switching capacity.)
Operate time (at nominal voltage) (at 20C 68F) Max. 10 ms
Release time (at nominal voltage) (at 20C 68F) Max. 5 ms
Mechanical
characteristics
Shock resistance
Functional Min. 147 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 3.5 mm
Expected life
Mechanical Min. 210
7
(at 180 times/min.)
Electrical
Min. 10
5
(3 A 250 V AC, 30 V DC, resistive load)
Min. 510
4
(5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)
Conditions
Conditions for operation, transport and storage*
3
Ambient temperature: 40C to 70C 40F to 158F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 3 g .15 oz
1. Max. switching capacity 2. Life curve 3.-(1) Coil temperature rise (120 mW)
Tested sample: PA1a-12V
Measured portion: Inside the coil
Ambient temperature: 20C 68F
0.2
0.3
0.4
0.5
1
2
3
4
5
2030 50 100 200 300
Contact voltage, V
C
o
n
t
a
c
t
c
u
r
r
e
n
t
,
A
DC resistive load
AC resistive load
10
20
30
50
100
0.5 1 2 3 5 10 100
Switching capacity, A
N
o
.
o
f
o
p
e
r
a
t
i
o
n
s
,
1
0
4
AC 125 V resistive load
DC 30 V resistive load
AC 250 V resistive load
10
20
30
0
40
50
60
70
80
90
100
100 110 120 130 140 150
3A
5A
Coil applied voltage, %V
T
e
m
p
e
r
a
t
u
r
e
r
i
s
e
,
C
2A
0A
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PA
ASCTB204E 201202-T
DIMENSIONS (mm inch)
SAFETY STANDARDS
UL/C-UL (Recognized) CSA (Certied) TV (Certied)
Remarks
File No. Contact rating File No. Contact rating File No. Rating
E43149 3A 250V AC (10
5
)
3A 30V DC (10
5
)
5A 250V AC (510
4
)
5A 250V AC (510
4
)
LR26550
etc.
5A 250V AC (510
4
)
5A 30V DC (510
4
)
3A 250V AC (10
5
)
3A 30V DC (10
5
)
B 01 08
13461 209
IEL1131-2
Reinforced
TV rating
5A 250V AC (cos=1.0) (510
4
)
5A 30V AC (0ms) (510
4
)
3A 250V AC (cos=1.0) (10
5
)
3A 30V AC (0ms) (10
5
)
3.-(2) Coil temperature rise (180 mW)
Tested sample: PA1a-24V
Measured portion: Inside the coil
Ambient temperature: 20C 68F
4.-(1) Operate & release time (120 mW)
Tested sample: PA1a-12V, 20 pcs.
4.-(2) Operate & release time (180 mW)
Tested sample: PA1a-24V, 20 pcs.
10
20
30
0
40
50
60
70
80
90
100
100 110 120 130 140 150
3A
5A
Coil applied voltage, %V
T
e
m
p
e
r
a
t
u
r
e
r
i
s
e
,
C
2A
0A
0
1
2
3
4
5
6
7
8
9
10
80 90 100 110 120
Min.
x
Max.
Max.
Min.
Coil applied voltage, %V
O
p
e
r
a
t
e
&
r
e
l
e
a
s
e
t
i
m
e
,
m
s
x
Operate time
Release time
0
1
2
3
4
5
6
7
8
9
10
80 90 100 110 120
Max.
x
x
Max.
Min.
Min.
Coil applied voltage, %V
O
p
e
r
a
t
e
&
r
e
l
e
a
s
e
t
i
m
e
,
m
s
Operate time
Release time
5. Ambient temperature characteristics
Tested sample: PA1a-12V, 6 pcs.
6. Malfunctional shock
Tested sample: PA1a-12V, 6 pcs.
40 20 0 20 50 75
20
10
10
20
30
40
30
40
Ambient
temperature, C
R
a
t
e
o
f
c
h
a
n
g
e
,
%
Pick-up voltage
Drop-out voltage
Y
Y
X Z
Z X
Y
Y
Z
X
X
Z
980m/s
2
980m/s
2
Energized
condition
Deenergized
condition
980m/s
2
980m/s
2
980m/s
2
980m/s
2
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
Relay
External dimensions
General tolerance: 0.3 .012
1.2
0.5
0.8 0.25
1.18 1.11
1.3
2.9
8.8
6
5
10.16
4.8
12.5
(12.8 max.)
0.5
3.5
2.54
20
5.08
.031 .010
.046 .044
.020
.400 .100
.787
.200
.047
.114
.197
.020
.138
.492
(.504 max.)
.051
.346
.237
.189
PC board pattern (Bottom view)
Tolerance: 0.1 .004
Schematic (Bottom view)
2.54 10.16 5.08
1.0 dia.
1.0 dia.
1.2 dia.
1.2 dia.
.100 .400 .200
.039 dia.
.039dia.
.047 dia.
.047 dia.
N.O. COM
Coil
CAD Data
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
PA
ASCTB204E 201202-T
NOTES
For Cautions for Use.
1. If it includes ripple, the ripple factor
should be less than 5%.
2. Specication values for pick-up and
drop-out voltages are for the relay
mounting with its terminals below.
3. When mounting the relays within 1 mm
.039 inch, please notice the condition
below.
1) Mount the relays in the same direction.
2) Coil terminals (Terminal No. 1 & 2)
polarity should be arranged in the same
direction.
3) Allowable contact current is 2 A.
4) About the electrical life for close
mounting, please refer to data below.
100
90
80
70
60
50
40
30
20
10
0
Max.
Max.
Mounting
direction
Min.
Min.
x
Pick-up voltage
Drop-out voltage
V
o
l
t
a
g
e
,
%
V
Within 1 mm
.039 inch
+ .
.
.
+ .
+ .
.
+ .
.
+ .
.
+ .
.
.
+ .
.
+ .
.
+ .
.
+ .
AC resistive load
C
o
n
t
a
c
t
c
u
r
r
e
n
t
,
A
DC resistive load
Contact voltage, V
20
3.0
2.0
1.0
0.5
0.4
0.3
0.2
30 50 100 200 300
N
o
.
o
f
o
p
e
r
a
t
i
o
n
s
,
1
0
4
Switching capacity, A
0.5 1.0 2.0 3.0
50
100
40
30
20
10
AC 125V
resistive load
DC 30 V
resistive load
AC 250 V
resistive load