Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Yokogawa DIN CE

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

Distributed by:

DIN METER SERIES

Yokogawa Corporation of America


WESCHLER INSTRUMENTS
800-903-9870 440-378-6580 www.weschler.com info@weschler.com

Contents
Meter Product Line-up Usage Precautions Specifications Scale forms and divisions Standard Specifications Catalog Numbers DC Ammeters DC Voltmeters Suppressed Meters (DC Ammeters & Voltmeters) AC Ammeters (Mean Rectifier Type) AC Voltmeters (Mean Rectifier Type) AC Ammeters (Moving Iron Type) AC Voltmeters (Moving Iron Type) Frequency Meters Wattmeters Varmeters Power Factor Meters Dimensions and Panel Mountings Connection Diagrams
2 3 4 6 8 9
10 13 15 16 17 18 20 22 23 25 27 29 30

Meter Product Line-up


Model DN96 DN72

Size

Page

9696 Name Ammeters Suspension type Taut band Pivot & jewel Taut band Pivot & jewel Taut band Pivot & jewel Taut band Pivot & jewel Taut band Pivot & jewel Pivot & jewel Taut band Pivot & jewel Moving iron type Differential type Mean rectifier type Moving coil type Operating principle Symbol

7272


Feedback time division multiplier type

DC

Voltmeters Ammeters, Voltmeters, Suppressed meters Ammeters

11

13

15

AC

Voltmeters Ammeters Voltmeters Frequency meters 1P2W

16

17,18,19

20

Wattmeters

3P3W 3P4W

Unbal. Bal. Unbal.

21,22

1P2W 3P3W Bal. Unbal. Bal. Unbal. Taut band

Varmeters

23,24

3P4W

1P2W Power factor meters 3P3W 3P4W Bal. Unbal. Unbal.

Phase detection type Feedback time division multiplier type

25,26

Remark: shows these meters needs external transducer.

Usage UsagePrecautions Precautions -

Safety instructions for DIN meters

Warning Indicates usage precautions that must be read to ensure the safety of users and the equipment.

1. Usage environment & conditions Do not use YOKOGAWA DIN meters in locations such as the following: Locations where the ambient temperature is outside the range of 0-45. Locations where relative humidity is outside the range of 30-75%. Locations subject to vibrations or shock impact. Locations subject to rain, dripping water, or direct sunlight. Locations exposed to large amounts of dust, salt, soot, or corrosive gases (sulfurous acid gas, ammonia gas, hydrogen sulfide gas, or other gases that corrode metals of plastics) Locations subject to strong external noise or electromagnetic waves. Locations subject to large amounts of static electricity. Locations subject to large amounts of high frequencies and waveform distortion(e.g., from inverters or thyristor circuits) 2. Mounting method Adhere to safety rule at the construction, maintenance and inspection Check the appearance of the packing box and DIN meters and confirm that there is no damage If necessary, combine with washers and others and fasten, in the case of panel boards and switchboards are thin. Fasten nuts on clamp panel mount to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque: M3 screws 0.6Nm 3. Wiring Adhere to the following rules when connecting the wires: When connecting an instrument with accessories, first make sure none of the wires are live. The connector terminals on the wires should be appropriate for the electricity load and terminal size. Connect the wires properly as illustrated in the wiring diagrams of the catalog or on the product labels. Attach to terminal cover for safety. Fasten terminal screws to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque: M3 screws 0.6Nm M4 screws 1.2Nm Instruments that are combined with current transformers (CT) should be properly connected to the secondary side of the CT. Improper

connection may result in a CT failure, burned components, or a fire. When the secondary side of a CT is disconnected, especially while the primary side is powered, the secondary side terminal will carry a high voltage which could result in electrical shock. Therefore, the secondary side should be short-circuited before the instrument is disconnected. 4. Usage precautions Use the instrument within the rated specifications. Failure to do so can cause the equipment to malfunction or result in a failure. While the power is on, do not touch any terminals or open the cover or case. The current transformer emits heat while powered, so do not touch it. 5. What to do if the equipment functions abnormally or fails If you notice abnormal heating, or a strange odor, noises, or smoking or if the equipment seems to have failed, immediately take steps such as cutting off the input. Next, contact your YOKOGAWA sales office. 6. Maintenance and inspection To ensure that your instrument operates properly, perform the following checks on a regular basis: Check for damage to the instrument or accessories due to heating or other factors. Check for loose attachments or screws (always turn off the power before doing this to ensure safety). The instrument covers have been coated with an antistatic agent to block static electricity. Gently wipe dirt off the cover surfaces with a soft, dry cloth. Do not use a wet cloth as this will reduce the effects of the antistatic coating. Do not allow cloths made from synthetic materials to contact the cover for an extended period of time, and do not use benzene, paint thinner, or similar substances. Doing so may cause the cover to become deformed, discolor it, or cause cracking. If the indicator reading becomes unstable due to static electricity, coat the front and back of the cover with a commercially available antistatic agent. Instrument service life will vary according to usage conditions. In general, however, we recommend replacing the instrument after about 10 years of use. 7. Disposal of product Panel meters do not contain batteries. Dispose of panel meters as general industrial waste. 8. For aluminum electrolytic capacitors Frequency meters use aluminum electrolytic capacitors. The lifetime of aluminum electrolytic capacitors are around 10 years when ambient temperatures are 23. If aluminum electrolytic capacitors run down and the meters are damaged, replace new frequency meters.

Specification Specifications
Front view(DN72 And DN96 Series Except DN96A22,23,82,83)
Division Units Scale Pointer Numerals CT/VT ratio Bezel YOKOGAWA logo Zero adjust

Dielectric strength

Mounting position Operating principle Accuracy class

Type

Front view (DN96A22,23,82,83)

Scale Units

Division

Numerals

Bezel Mounting position Accuracy class Pointer Dielectric strength YOKOGAWA LOGO

Type Operating principle

Zero adjust

Back view(DN72 And DN96 Series Except DN96A22,23,82,83)

Safety terminal cover


The clear cover is used to prevent touching the input terminals. Dont forget to close this cover. Object: All DIN series meters.

Back view(DN96A22,23,82,83)

Safety terminal cover


The clear cover is used to prevent touching the input terminals. Dont forget to close this cover. Object: All DIN series meters. Note:Circuit I and II are independent.

Set pointer

Set pointerred
Easy to manage, the pointer can be set to any value.

Note:The double pointer meter does not have a set pointer.

Scale forms and divisions Scale Forms and Divisions


Scale form
a) Types of division
b) Standard scale (Except moving iron type)

Linear scales
Major line Minor line Medium line

c) Moving iron type


Non-linear scales. Lines near 0 are omitted because of limited space and low usage.

d) Suppressed meters
In the case of 4-20mA current input, when value to be input is 4mA, the pointer read 0; when the value to be input is 0mA, the pointer points to the mechanical zero,

e) Extended scale (Moving iron type)


Two-fold extended Three-fold extended

Used in measuring the loading current of the electromotor. The Colored scales and figures with red, which are beyond the effective range. This kind is used to measure the starting current.

f) Zero-center meter

g) Color of scale
Colored figure Colored lined

Zero-center: the scale division is the same as the standard scale.

Confirm the color is red, green, blue or yellow. Colored line, colored field: maximum 2 piece / 2 color. Colored figure: maximum 2 piece 1color.

Colored field

h) Multiple-division & multiple-marking


The larger scale is on external side; the smaller one is on inner side. Multiple-division is as the same as the standard scale.
Single-division double-marking Double-division double-marking

Scale division
Maximum scale value Value of per division Division 50 division 1 10 100 0.02 0.2 2 4.5 45 450 0.1 1 10 Maximum scale value Value of per division Division 45 division

24 division 1.2 12 120 0.05 0.5 5 5 50 500 0.1 1 10

50 division

30 division 1.5 15 150 0.05 0.5 5 6 60 600 0.2 2 20

30 division

40 division 2 20 200 0.05 0.5 5 7.5 75 750 0.2 2 20

37.5 division

50 division 2.5 25 250 0.05 0.5 5 8 80 800 0.2 2 20

40 division

30 division 3 30 300 0.1 1 10 9 90 900 0.2 2 20

45 division

40 division 4 40 400 0.1 1 10

Standard Specifications Standard Specifications


Item Suspension type Pointer type Bezel color Front cover dimensions Scale length The length between element center and pointer end Full scale deflection angle Meter mounting position Insulation resistance Taut band DN96 Pivot & jewel Taut band DN72

Pivot & jewel

Lance type (black color) Black 9696mm 53mmDN9622,23,82,83 95mmDN96Series others 33.7mmDN9622,23,82,83 60.5mmDN96Series others 902 Vertical

Lance type(black color) Black 7272mm 61mm

39mm

Between electrical circuit and the case:500V DC/More than 10M Between current circuit and voltage circuit:500V DC/More than 5M Linemax:500V (Ammeters only) Between electrical circuit and the case(I/V): 3320V AC for 5S; Between electrical circuit and case(FREQ., WATT,P.F.,VAR):3320 AC for 5Sbetween current circuit and case:2600V AC for 5S; Others2210V AC for 5S; Between electrical circuit I and II with double pointer meter: 3320V AC for 5S 045 3075%RH -1050 2580%RH Case & base material ABS resinNonflammable

Dielectric strength

Operating temperature range Operating humidity range Storage temperature range Storage humidity range

Case material

Window materialPMMAUnit electrostatic process Bezel materialABS resinNonflammable DC A1mA AC AAVE AC A (I/V) WATT33W Approx 160g Approx 160g(DN96A20,21) Approx 220g(DN96A22,23) Approx 155g Approx 320g Approx 320g Approx 320g Approx 172g(DN96A80,81) FRQ. Approx 220g(DN96A82,83) Approx 125g Approx 115g Approx 115g Approx 115g Approx 115g (TRD BOX 460g) Approx 115g (TRD BOX 460g) Approx 115g (TRD BOX 460g)

Meter weight

VAR33W P.F.33W

Catalog Numbers Catalog Numbers


DNA----/
SHAPE & DIMENSION DN96 DN72 96X96 72X72 TYPE CODE 10 11 20 21 22 23 31 51 52 54 55 56 61 63 64 65 66 71 73 75 76 80 81 82 83 T/B type DC Ammeter, Voltmeters P/J type DC Ammeter, Voltmeters T/B type rectifying AC Ammeters, Voltmeters P/J type rectifying AC Ammeters, Voltmeters
T/B type rectifying AC Voltmeters(Double pointer,Only DN96) P/J type rectifying AC Voltmeters(Double pointer,Only DN96)

I/V type AC Ammeters, Voltmeters (P/J type only) Watt Meters 1P2W Watt Meters 1P3W Watt Meters 3P4W BAL Watt Meters 3P3W UNBAL Watt Meters 3P4W UNBAL Var Meters 1P2W Var Meters 3P3W BAL Var Meters 3P4W BAL Var Meters 3P3W UNBAL Var Meters 3P4W UNBAL Power Factor Meter 1P2W Power Factor Meter 3P3W BAL Power Factor Meter 3P3W UNBAL Power Factor Meter 3P4W UNBAL Frequency Meters (T/B type Frequency Meters (P/J type)
Frequency Meters (T/B type) (Double pointer,Only DN96) Frequency Meters (P/J type) (Double pointer,Only DN96)

T/B type

INPUT CODE

See rating input code table RATED FREQUENCY DC & rectifying AC(402kHz), I/V type AC(50/60Hz) 50Hz Var & Power Factor 60Hz Var & Power Factor 400Hz I/V type AC

N A B C

POINTER L Spear type (black) WINDOW & BEZEL BL BS Clear (black) Set pointer (red).Double pointer meter has no set pointer.

OPTIONAL INPUT CODE See rating input code table

DC Ammeters DC Ammeters
Specify the following information from Code: Ex. DN96A10
Model

10

when ordering L BL /
Optional f t

AFA
Suffix Code

Always N

Pointer

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 1mA) Optional feature: If necessary, specify optional feature.

Product line-up
Model Taut band DN96A10 DN72A10 Pivot & jewel DN96A11 DN72A11 Descriptions Dimensions Operating (Width Height) principle 96 96 72 72 Moving coil type Accuracy class 1.5

Standard descriptions
Name DC Ammeters Self-contained Suffix codes -ABZ -ACJ -ACY -ADR -ADX -AEA -AEG -AEM -AEU -AFA -AFD -AFG -AFN -AFX -AGN -AGZ -AHC -AHF -AHM -AHY -AJG -AJR -AJX -AKA -AKG -AKM -AKU -ALA -ALC -ALE -ALJ -ALS -AMF -AMT -AND -ANG -ANL -A01 -A04 -A05 -A07 -A06 Available range 010A 025A 050A 0100A 0150A 0200A 0300A 0500A 0750A 01mA 01.5mA 02mA 03mA 05mA 07.5mA 010mA 015mA 020mA 030mA 050mA 075mA 0100mA 0150mA 0200mA 0300mA 0500mA 0750mA 01A 01.5A 02A 03A 05A 07.5A 010A 015A 020A 030A 050mV 060mV 0100mV 075mV 050mV Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 5900 3700 2000 6000 484 1950 1315 3310 121 980 680 1670 40 226 132 407 10.5 42.4 33.1 66 7.2 22.4 16.4 29.6 Notes Suspension type is taut band

50mV

For external shunt


1,3

24.8 61.5 101.5


2

12.5 15.3 24.3

Meter with VR

Standard descriptions
Name DC Ammeters Zero-center meter Suffix codes -DAX -DCJ -DCY -DDH -DDR -DDX -DED -DEM -DEU -DFA -DFD -DFK -DFX -DGN -DGZ -DHC -DHJ -DHY -DJG -DJR -DJX -DKD -DKM -DKU -DLA -DLC -DLG -DLS -DMF -DMT -DND For external shunt
1,3

11
Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 5900 2000 484 1315 121 680 40 10.5 33.1 7.2 16.4 6000 1950 3310 980 1670 226 42.4 66 22.4 29.6 Notes Suspension type is taut band

Available range 5A 25A 50A 75A 100A 150A 250A 500A 750A 1mA 1.5mA 2.5mA 5mA 7.5mA 10mA 15mA 25mA 50mA 75mA 100mA 150mA 250mA 500mA 750mA 1A 1.5A 2.5A 5A 7.5A 10A 15A 50mV

25mV

-D01 -N -L -BL -BS

101.5

24.3

Designation of frequency used Pointer type Standard type Cover type With set pointer (red)

Always -N Lance type (black color) Clear Clear

Note:

1 The 50mV, 60mV, 75mV, 100mV and

50mV instruments are not provided with any shunt lead. Use any lead wire of which resistance is less than 0.05 in total. External shunts are not supplied.

2 For 50mV instrument with VR, current consumption is 1mA and shunt leads resistance compensates 2 to 0. 3 An external shunt is not supplied.

Optional feature
Code /003 /004 /005 /006 /007 /008 /011 /012 /013 /015 /016 /018 /022 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Shunt leads resistance Designation of Internal Resistance Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Vibration proof Pass the attestation used in ship (IP42) Used in DN72A10,DN96A10 Used in DN72A10,11 Notes

12

DC Voltmeters
Specify the following information from Code: Ex. DN96A10
Model

13 when ordering L BL /
Optional f t

VNT
Suffix Code

Always N

Pointer

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 50V) Optional feature: If necessary, specify optional feature. Range: For suffix V04, V05, V08, V11, specify rating.

Product line-up
Model Taut band DN96A10 DN72A10 Pivot & jewel DN96A11 DN72A11 Descriptions Dimensions (Width Height) 96 96 72 72 Operating principle Moving coil type Accuracy class

1.5

Standard descriptions
Name DC Voltmeters Self-contained Suffix codes -VKM -VLA -VLC -VLE -VLJ -VLS -VMF -VMT -VND -VNG -VNL -VNT -VPB -VPK -VPZ -VRL -VRX -VSD -VSF -VSJ
3

Available range 00.5V 01V 01.5V 02V 03V 05V 07.5V 010V 015V 020V 030V 050V 075V 0100V 0150V 0200V 0300V 0450V 0500V 0600V 01mA
1

Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel

Notes

1mA

For external multiplier

-V01 -V04

10.5 V/50A V/100A V/500A


2

42.4

Specified loss current for direct instrument Meter with VR Notes:


-V05 -V08 -V11

0(1300)V

V/1mA

1 Specify from the above-mentioned rating between 0.5V and 300V. 2 20% Variable. 3 An external multiplier is not supplied

Standard descriptions
Name DC Ammeters Zero-center meter Suffix codes -EKD -EKM -EKU -ELA -ELC -ELG -ELS -EMF -EMT -END -ENJ -ENT -EPB -EPK -EPZ -ERS -ERX
3

14
Available range 0.25V 0.5V 0.75V 1V 1.5V 2.5V 5V 7.5V 10V 15V 25V 50V 75V 100V 150V 250V 300V 1mA 7.2 Always -N Lance type (black color) Clear Clear Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel Notes

0.5mA

For external multiplier Designation of frequency used Pointer type Standard type Cover type With set pointer (red)

-E01 -N -L -BL -BS

22.4

Optional feature
Code /003 /004 /005 /006 /007 /008 /011 /012 /013 /015 /016 /018 /022 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Notes

Shunt leads resistance


Designation of Internal Resistance Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Vibration proof Pass the attestation used in ship (IP42) Used in DN72A10,DN96A10 Used in DN72A10,11

Suppressed Meters Suppressed Meters (DC Ammeters & Voltmeters)


Specify following information from Code: Ex. DN96A10
Model

15

when ordering N L
Pointer

AHE
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 750) Optional feature: If necessary, specify optional feature.

Product line-up
Model Taut band DN96A10 DN72A10 Pivot & jewel DN96A11 DN72A11 Descriptions Dimensions (Width Height) 96 96 72 72 Operating principle Moving coil type Accuracy class 1.5

Standard descriptions
Name Suppressed meters DC Ammeters Suffix codes -AHE -AHX -A11 -A12 -A13 -VLR -N -L -BL -BS Available range 420mA 1050mA 0.21mA 15mA 210mA 15V Always -N Lance type (black color) Clear Clear Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 3.1 3 1.2 2.4 125 12.2 6.2 3.9 Notes

DC Voltmeters Designation of frequency used Pointer type Standard type Cover type With set pointer (red)

Optional feature
Code /003 /004 /005 /006 /007 /008 /010 /013 /015 /016 /018 /022 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position AC symbol mark Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Vibration proof Pass the attestation used in ship (IP42) Used in DN72A10,DN96A10 Used in DN72A10,11 Notes

AC Ammeters (Mean Rectifier Type) AC Ammeters (Mean Rectifier Type)


Specify following information from Code: Ex. DN96A20
Model

16

when ordering N L
Pointer

AEA
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 200A) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio.

Product line-up
Model Taut band DN96A20 DN72A20 Pivot & jewel DN96A21 DN72A21 Dimensions (Width Height) 96 96 72 72 Descriptions Operating principle Mean rectifier type Accuracy class 1.5

Standard descriptions
Name AC Ammeters Self-contained Suffix codes -AEA -AEM -AFA -AFG -AFX -AGZ -AHF
1

Available range 0200A 0500A 01mA 02mA 05mA 010mA 020mA

Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 2536 3380 1286 1470 774 797 508 507 285 292 207 181 118 94 181

Notes

For external CT Designation of frequency used Pointer type Standard type Cover type With set pointer (red) Notes:

-A40 -N -L -BL -BS

1 207 010mA Always -N (40Hz to 2kHz) Lance type (black color) Clear Clear

1 An external CT is not supplied. If necessary, externally connect a CT(224800).

Optional feature
Code /003 /004 /005 /006 /007 /008 /013 /015 /016 /018 /022 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Vibration proof Pass the attestation used in ship (IP42) Used in DN72A20,DN96A20 Notes

AC Voltmeters (Mean Rectifier Type)


Specify following information from Code: Ex. DN96A20
Model

17

when ordering N L
Pointer

VRX
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V) Range: For suffix code V06, V08, V11, specify rating. Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio.

Product line-up
Model Type Taut band DN96A20 DN96A22 DN72A20 Pivot & jewel DN96A21 DN96A23 DN72A21 Dimensions (Width Height) 96 96 72 72 Descriptions Operating principle Mean rectifier type Accuracy class 1.5

Double pointer

Standard descriptions
Name AC Voltmeter Self-contained Suffix codes -VLJ -VLS -VMT -VND -VNL -VNT -VPB -VPK -VPZ -VRL -VRX -V01 -V12 -V51 -V52 -V53 -V06 -V08 -V11 -N -L -BL -BS Available range 03V 05V 010V 015V 030V 050V 075V 0100V 0150V 0200V 0300V 01mA 0150V 0275V 0289.5V 0293.3V
1

For external multiplier


3

For external VT

Internal resistance Taut band Pivot & jewel 3k 2.8 k 5 k 4.7 k 9.8 k 9.6 k 15 k 14.8 k 30 k 29.8 k 48.5 k 75 101.6 k 151.6 k 201.6 k 301.6 k 774 797 k 151.6 k 271.6 k 301.6 k V/200A V/500A V/1mA

Notes

Specified loss current for direct instrument Meter with VR Designation of frequency used Pointer type Standard type Cover type With set pointer (red)

03V, 05V,, Always -N (40Hz to 2kHz) Lance type (black color) Clear Clear

Optional feature
Code /003 /004 /005 /006 /007 /008 /013 /015 /016 /018 /022 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Vibration proof Pass the attestation used in ship (IP42) Used in DN72A20,DN96A20 Notes

AC AC Ammeters (Moving Iron Type) Ammeters (Moving Iron Type)


Specify following information from Code: Ex. DN96A31
Model

18

when ordering N L
Pointer

A42
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 300A) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio. (Ex. 300/5A)

Product line-up
Model Pivot & jewel DN96A31 DN72A31 Dimensions (Width Height) 96 96 72 72 Descriptions Operating principle Accuracy class 1.5

Mean rectifier type

Standard descriptions
Name AC Ammeters Suffix codes -AHY -AJR -AJX -AKG -AKM -ALA -ALC -ALE -ALJ -ALS -AMF -AMT -AND -ANG -ANL -A21 -A22 -A23 -A24 -A25 -A26 -A27 -A28 -A29 -A32 -A33 -A34 -A35 -A36 -A37 -A38 -A41 -A42 -A43 -A44 -A45 -A46 Available range 050mA 0100mA 0150mA 0300mA 0500mA 01A 01.5A 02A 03A 05A 07.5A 010A 015A 020A 030A 00.51A 012A 024A 036A 0510A 01020A 01530A 02040A 03060A 013A 026A 039A 0515A 01030A 01545A 02060A 01A 05A 012A 0510A 013A 0515A Power consumption VA 0.4 0.4 0.3 0.4 0.4 0.4 0.3 0.4 0.4 0.5 0.4 0.4 0.6 0.7 0.6 0.4 0.4 0.4 0.4 0.5 0.4 0.6 0.7 0.6 0.4 0.4 0.4 0.5 0.4 0.6 0.7 0.4 0.5 0.4 0.5 0.4 0.5 Notes

Two-fold extended

Three-fold extended

For external CT

Two-fold extended (For external CT ) Three-fold extended (For external CT


1 1

Standard descriptions
Name Designation of frequency used Pointer type Cover type Note:

19
Available range Current 50/60Hz 400Hz Lance type (black color) Clear Clear Notes

Suffix codes -N -C -L Clear Clear

-BL -BS

1 An external CT is not supplied.

Optional feature
Code /003 /004 /005 /006 /007 /008 /013 /015 /016 /018 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Pass the attestation used in ship (IP42) Used in DN72A30 Notes

AC Voltmeters (Moving Iron Type)


Specify following information from Code: Ex. DN96A30
Model

20

when ordering N L
Pointer

VRX
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify VT ratio.

Product line-up
Model Pivot & jewel DN96A31 DN72A31 Dimensions (Width Height) 96 96 72 72 Descriptions Operating principle Mean rectifier type Accuracy class 1.5

Standard descriptions
Name AC Ammeters Self-contained Suffix codes -VMT -VND -VNG -VNL -VNT -VPB -VPK -VPZ -VRL -VRS -VRX -VSD -VSF -VSJ -V14 For external VT Designation of frequency used Pointer type Cover type Note:
1

Available range 010V 015V 020V 030V 050V 075V 0100V 0150V 0200V 0250V 0300V 0450V 0500V 0600V 0150/ 3 V 0150V

Power consumption VA 1.6 1.2 1.7 1.5 1.6 1.3 1.6 1.4 1.3 1.6 1.4 1.8 2.2 1.5 1.4

Notes

-V12 -N -C -L -BL -BS

Standard type With set pointer (red)

50/60Hz 400Hz Lance type (black color) Clear Clear

1 An external multiplier and VT are not supplied.

Optional feature
Code /003 /004 /005 /006 /007 /008 /013 /015 /016 /018 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Class up Triple set of numbers - Double set of divisions Triple set of numbers - Triple set of divisions Except Yokogawa standard scale divisions Pass the attestation used in ship (IP42) Used in DN72A30 Notes

21

Frequency Meters
Specify following information from Code: Ex. DN96A80
Model

22 when ordering N L
Pointer

H11
Suffix Code

BL

Optional f t

Always N

Cover color & set pointer

Optional feature: If necessary, specify optional feature.

Product line-up
Model Type Taut band DN96A80 Double pointer DN96A82 DN72A80 Pivot & jewel DN96A81 DN96A83 DN72A81 Dimensions (Width Height) 96 96 72 72 Descriptions Operating principle Differential type

Accuracy class

0.5 or 1.0

Standard descriptions
Name Frequency meters Suffix codes -H30 -H31 -H32 -H10 -H11 -H12 -H40 -H41 -H42 -H50 -H51 -H52 -H20 -H21 -H22 -H60 -H61 -H62 -N -L -BL -BS Available range 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 50/60Hz Lance type (black color) Clear Clear Available range 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 Power consumption VA Operating range Notes

100V

110V

0.4

80130V

115V

200V

220V

0.8

160260V

230V

Designation of frequency used Pointer type Standard type Cover With set pointer type (red)

Optional feature
Code /005 /006 /007 /008 /022 /CJ Feature Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Vibration proof Pass the attestation used in ship (IP42) Used in DN72A80,DN96A80 Notes

Wattmeters
Specify following information from Code: Ex. DN96A55
Model

23 when ordering N L BL /
Optional f t

W14
Suffix Code

Always N

Pointer

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 120kW) Calibration watts: In case of using external CT and/of VT, calculate the possible full scale from the follow page and be sure that is within the range shown above. (Ex. 750W) Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 440/110V)

Product line-up
Model (Taut band) 1P2W DN96A51 DN72A51 1P3W DN96A52 DN72A52 3P3W Unbal DN96A55 DN72A55 3P4W Bal. DN96A54 DN72A54 Unbal. DN96A56 DN72A56 Dimensions (WidthHeight) 9696 7272 Operating principle Feedback time division multiplier type Accuracy class 1.5 Transducer Self contained External box

Standard descriptions
Name Wattmeters Suffix codes -W71 -W72 -W51 -W52 -W01 -W02 -W11 -W12 -W03 -W04 -W13 -W14 -W73 -W74 -W53 -W54 -W75 -W76 -W55 -W56 -W81 -W82 -W61 -W62 -W05 -W06 -W15 -W16 -W83 -W84 -W63 -W64 -W85 -W86 -W65 -W66 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A Available range Current 100V Voltage Notes

110/ 3 V

110V

115V

120V

200V

220V

230V

240V

Standard descriptions
Name Designation of frequency used Pointer type -BL Cover type -BS Suffix codes -N -L Clear Clear Available range Current 50/60Hz Lance type (black color) Clear Clear Notes

24

Optional feature
Code /003 /004 /005 /006 /007 /008 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Pass the attestation used in ship (IP42) Notes

Available standard calibration watts Model


Rating Voltage 110/ 3 V 110V, 115V, 120V 220/ 3 V 200V, 220V, 240V Current 1A 5A 1A 5A 1A 5A 1A 5A Single phase 2-wire DN96A51 DN72A51 32 to 95W 160 to 475W 55 to 164W 275 to 820W 110 to 328W 550 to 1640W Single phase 3-wire DN96A52 DN72A52 95 to 285W 475 to 1400W 250 to 570W 1250 to 2850W 3-phase 3-wire DN96A55 DN72A55 95 to 285W 475 to 1400W 250 to 570W 1250 to 2850W 3-phase 4-wire DN96A54/56 DN72A54/56 95 to 285W 475 to 1400W 218 to 495W 1090 to 2475W 250 to 570W 1250 to 2850W 430 to 990W 2150 to 4950W

(1) When using VT and/or CT, calibration watts will be as follows;


MAX. Full scale value VT ratio CT ratio

Calibration watts =

Connection EX.1 EX.2 3-phase 3-wire Single phase 2-wire

Full scale value 20kW 7.5kW

VT ratio 440/110V 660/110V

CT ratio 30/5A 20/5A FS= FS= 20kW 440/11030/5 7.5kW 660/11020/5

Calibration watts =833.3W Available

=833.3W Special order with TOKUCHU sheet

(2) Calibration watts are 65 to 150%. Standard watts beyond the limits are not available.
Single phase 2-wire: Standard watts = Voltage rating Current rating 3-phase 3-wire: Standard watts = 3 Line voltage rating Current rating 3-phase 4-wire: Standard watts = 3 Phase voltage rating Current rating

Varmeters
Specify following information from Code: Ex. DN96A65
Model

25 when ordering N L BL /
Optional f t

M14
Suffix Code

Always N

Pointer

Cover color & set pointer

Scale and unit: Specify full scale value and unit. (Ex. 0 to 10kvar) Calibration watts: In case of using external CT and/of VT, calculate the possible full scale from the follow page and be sure that is within the range shown above. (Ex. 416.6 var) Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 660/110V) CT ratio: If necessary, specify CT ratio. (Ex. 20/5V)

Product line-up
Model (Taut band) 1P2W DN96A61 DN72A61 3P3W Bal. DN96A63 DN72A63 Unbal DN96A65 DN72A65 Bal. DN96A64 DN72A64 3P4W Unbal Self contained External box Dimensions (WidthHeight) 9696 7272 Operating principle Feedback time division multiplier type Accuracy class Transducer Self contained 1.5 External box

Standard descriptions
Name Varmeters Suffix codes -M71 -M72 -M51 -M52 -M01 -M02 -M11 -M12 -M03 -M04 -M13 -M14 -M73 -M74 -M53 -M54 -M75 -M76 -M55 -M56 -M81 -M82 -M61 -M62 -M05 -M06 -M15 -M16 -M83 -M84 -M63 -M64 -M85 -M86 -M65 -M66 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A Available range Current 100V Voltage Notes

110/ 3 V

110V

115V

120V

200V

220V

230V

240V

Standard descriptions
Name Designation of frequency used Pointer type Cover type Standard type With set pointer (red) Suffix codes -N -A -B -L Clear Clear Available range Current 50/60Hz 50Hz 60Hz Lance type (black color) Clear Clear Notes For DNA63, DNA64 For DNA61, DNA65, DNA66.

26

Optional feature
Code /003 /004 /005 /006 /007 /008 /009 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Polarity change marking (LAG to LEAD) Pass the attestation used in ship (IP42) Notes

Available standard calibration vars(Zero-center meter) Model


Single phase 2-wire Rating Voltage 110/ 3 V 110V, 115V, 120V 220/ 3 V 200V, 220V, 240V Current 1A 5A 1A 5A 1A 5A 1A 5A DN96A51 DN72A51 21 to 95 var 105 to 475 var 36 to 164 var 180 to 820 var 72 to 328 var 360 to 1640 var 3-phase 3-wire (Unbalanced) DN96A55 DN72A55 95 to 285 var 475 to 1400 var 190 to 570 var 950 to 2850 var 3-phase 3-wire(Balanced) 3-phase 4-wire(Balanced) DN96A53/54 DN72A53/54 62 to 285 var 312 to 1400 var 125 to 570 var 625 to 2850 var 3-phase 4-wire (Unbalanced) DN96A56 DN72A56 190 to 570 var 950 to 2850 var

(1) When using VT and/or CT, calibration vars will be as follows;


Calibration vars = MAX. Full scale value VT ratio CT ratio

Connection EX.1 EX.2 3-phase 3-wire (Balanced) 3-phase 2-wire (Unbalanced)

Full scale value 10kvar 7.5kvar

VT ratio 660/110V 660/110V

CT ratio 30/5A 20/5A FS= FS= 10kvar

Calibration vars =416.6 var Available =312.5 var Special order 660/11030/5 7.5kvar 660/11020/5

(2) Calibration vars are 33 to 150%. Standard vars beyond the limits are not available.
Single phase 2-wire: Standard vars = Voltage rating Current rating 3-phase 3-wire: Standard vars = 3 Line voltage rating Current rating 3-phase 4-wire: Standard vars = 3 Phase voltage rating Current rating

Power Factor Meters Power Fa


Specify following information from Code: Ex. DN96A75
Model

27 when ordering

C14
Suffix Code

L
Pointer

BL

Optional f t

Always N

Cover color & set pointer

Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 660/110V) CT ratio: If necessary, specify CT ratio. (Ex. 20/5V)

Product line-up
Model (Taut band) 1P2W DN96A71 DN72A71 3P3W Bal. DN96A73 DN72A73 Unbal DN96A75 DN72A75 3P4W Unbal. DN96A76 DN72A76 Dimensions (WidthHeight) Self contained External box Operating principle
Phase defection type For single-phase and 3-phase(balanced) Feedback time division multiplier type For 3-phase(unbalanced)

Accuracy class

Transducer

Self contained 5.0 External box

Standard descriptions
Name Power factor meters Single phase 2-wire 3-phase 3-wire Suffix codes -C71 -C72 -C51 -C52 -C01 -C02 -C13 -C14 -C73 -C74 -C53 -C54 -C75 -C76 -C55 -C56 -C81 -C82 -C61 -C62 -C03 -C04 -C15 -C16 -C83 -C84 -C63 -C64 -C85 -C86 -C65 -C66 -C07 -C08 -C11 -C12 Available range Current Voltage 0.1A 0.5A 100V 1A 5A 0.1A 0.5A 110V 1A 5A 0.1A 0.5A 115V 1A 5A 0.1A 0.5A 120V 1A 5A 0.1A 0.5A 200V 1A 5A 0.1A 0.5A 220V 1A 5A 0.1A 0.5A 230V 1A 5A 0.1A 0.5A 240V 1A 5A 0.1A 0.5A 110/ 3 V 1A 5A Notes For: DN96A71/73/75, DN72A71/73/75 Standard scale: LEAD 0.50.5 LAG

3-phase 4-wire

For: DN96A76, DN72A76

(Continued to next page)

Standard descriptions
Name Designation of frequency used Pointer type Cover type Standard type With set pointer (red) Suffix codes -N -A -B -L Clear Clear Available range Current 50/60Hz 50Hz 60Hz Lance type (black color) Clear Clear Notes For DNA73, DNA74 For DNA71, DNA75, DNA76.

28

Optional feature
Code /003 /004 /005 /006 /007 /008 /009 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Polarity change marking (LAG to LEAD) Pass the attestation used in ship (IP42) Notes

Standard rating
Rating Voltage 110/ 3 V 110V 220/ 3 V 220V Current 1A 5A 1A 5A 1A 5A 1A 5A Voltage 52 to 75 V 90 to 130 V 104 to 150 V 180 to 260 V Usable Current 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A

Dimensions and Panel Mountings


DN96 series
DN96A10,11 DN96A20,21, DN96A22,23 DN96A31 DN96A80,81, DN96A82,83

26 29

95.6

5.1

43.5

1 5.7

920.5

95.6

5.1

66.6

1 6.5

920.5

DN72 series
DN72A10,11 DN72A20,21 DN72A31 DN72A80,81

71 .7
40

5.1

43.5

1 5.7

680.5

External transducer:
DN72A5 DN72A6 DN72A7
O 98

1 60

1 40

98.5

680.5
O

71 .7

920.5
6.5

DN96A5 DN96A6 DN96A7

95.6

920.5

95.6

Connection Diagrams
DC Ammeters, Voltmeters
<With external shunt, multiplier>

30

<With high-tension multiplier>

DN96A10,11 DN72A10,11

AC Ammeters, Voltmeters

<With CT, VT>

DN96A20,21 DN72A20,21 DN96A31 DN72A31

DN96A22,23

Wattmeters
DN96A51 Single phase 2-wire DN72A51

31 DN96A55 DN72A55

3-phase 3-wire (Unbalanced)

DN96A54

DN72A54

3-phase 4-wire (Balanced)

DN96A56

DN72A56

3-phase 4-wire (Unbalanced)

Varmeters
DN96A61 DN72A61

Single phase 2-wire

32 DN96A63 DN72A63

3-phase 3-wire (Balanced)

DN96A65

DN72A65

3-phase 3-wire (Unalanced)

DN96A64

DN72A64

3-phase 4-wire (Balanced)

DN96A66

DN72A66

3-phase 4-wire (Unbalanced)

Power factor meters


DN96A71 DN72A71

33

Single phase 2-wire

DN96A73

DN72A73

3-phase 3-wire (Balanced)

DN96A75

DN72A75

3-phase 3-wire (Unbalanced)

DN96A76

DN72A76

3-phase 4-wire (Unbalanced)

Frequency meters

34

DN96A80,81 DN72A80,81

DN96A82,83

2 Dart Road Newnan, Georgia 30265 Phone: 800-888-6400

Distributor & Meter Modification Center:

WESCHLER INSTRUMENTS
phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com info@weschler.com

You might also like