Low Voltage Alternators - 4 Pole: 180 To 315 kVA - 50 HZ / 228 To 381 kVA - 60 HZ Electrical and Mechanical Data

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Low Voltage Alternators - 4 pole

LSA 46.2
180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz
Electrical and mechanical data
Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Specially adapted to applications


The LSA 46.2 alternator is designed to be suitable for typical generator applications, such as: backup, marine applications, rental,
telecommunications, etc.

Compliant with international standards


The LSA 46.2 alternator conforms to the main international standards and regulations:
- IEC 60034, NEMA MG 1.32-33, ISO 8528-3, CSA / UL 1446 (UL 1004 on request), marine regulations, etc.
It can be integrated into a CE marked generator.
The LSA 46.2 is designed, manufactured and marketed in an ISO 9001 and ISO 14001 environment.

Top of the range electrical performance


● Class H insulation.
● Standard 12-wire re-connectable winding, 2/3 pitch, type no. 6.
● Voltage range 50 Hz: 220 V - 240 V and 380 V - 415 V (440 V).
● Voltage range 60 Hz: 208 V - 240 V and 380 V - 480 V.
● High efficiency and motor starting capacity.
● Other voltages are possible with optional adapted windings:
- 50 Hz: 440 V (no. 7), 500 V (no. 9), 550 V (no. 22), 600 V (no. 23), 690 V (no. 10 or 52).
- 60 Hz: 380 V and 416 V (no. 8), 600 V (no. 9).
● R 791 interference suppression conforming to standard EN 55011 group 1 class B standard for European zone (CE marking).

Excitation and regulation system suited to the application


Excitation system Regulation options
Volage Current Mains 3-phase sensing for Remote voltage
3-phase
SHUNT AREP PMG transformer sensing mains paralleling
regulator for paralleling paralleling unbalanced potentiometer

R250 Std - - - - - - √
R450 Option Std Std C.T. R726 R731 R734 √
D510C Option Option Option C.T. included included contact factory √

√ : possible mounting
Protection system suited to the environment
● The LSA 46.2 is IP 23.
● Standard winding protection for clean environments with relative humidity ≤ 95 %, including indoor marine environments.
Options : - Filters on air inlet : derating 5%.
- Filters on air inlet and air outlet (IP 44) : derating 10%.
- Winding protections for harsh environments and relative humidity greater than 95%.
- Space heaters.
- Thermal protection for winding and shields.

Reinforced mechanical structure using finite element modelling


● Compact and rigid assembly to better withstand generator vibrations.
● Steel frame.
● Cast iron flanges and shields.
● Twin-bearing and single-bearing versions designed to be suitable for engines on the market.
● Half-key balancing.
● Sealed for life ball bearings, regreasable bearings (optional).

Accessible terminal box proportioned for optional equipment


● Easy access to the voltage regulator and to the connections.
● Possible inclusion of accessories for paralleling, protection and measurement.
● 12-way terminal block for voltage reconnection.

2 Electric Power Generation


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

General characteristics
Insulation class H Excitation system SHUNT AREP or PMG
Winding pitch 2/3 (N° 6) AVR type R 250 R 450
Number of wires 12 Voltage regulation (*) ± 0.5 % ± 0.5 %
Protection IP 23 Short-circuit current - 300% (3 IN) : 10s
Altitude ≤ 1000 m Totale Harmonic distortion THD (**) no load < 2.5% - on load < 2.5%
Overspeed 2250 min-1 Waveform: NEMA = TIF (**) < 50
Air flow 0.43 m3/s (50Hz) / 0.51 (60Hz)
(*) Steady state. (**) Total harmonic distortion between phases, no-load or on-load (non-distorting)

Ratings 50 Hz - 1500 R.P.M.


kVA / kW - P.F. = 0.8
Duty/T°C Continuous duty/40°C Continuous duty/40°C Stand-by/40°C Stand-by/27°C
Class/T°K H/125°K F/105°K H/150°K H/163°K
Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph.
Y 380V 400V 415V 440V ∆∆ 380V 400V 415V 440V ∆∆ 380V 400V 415V 440V ∆∆ 380V 400V 415V 440V ∆∆
∆ 220V 230V 240V 230V 220V 230V 240V 230V 220V 230V 240V 230V 220V 230V 240V 230V
YY 220V 220V 220V 220V
46.2 M3 kVA 180 180 180 160 104 168 168 168 146 97 195 195 195 175 110 203 203 203 180 114
kW 144 144 144 128 83 134 134 134 116 78 156 156 156 140 88 162 162 162 144 91
46.2 M5 kVA 200 200 200 175 116 184 184 184 160 108 214 214 214 190 123 223 223 223 200 127
kW 160 160 160 140 93 147 147 147 128 86 171 171 171 152 98 178 178 178 160 102
46.2 L6 kVA 250 250 240 205 141 217 217 217 190 131 254 260 254 225 150 266 275 266 237 156
kW 200 200 192 164 113 174 174 174 152 105 203 208 203 180 120 213 220 213 190 125
46.2 L9 kVA 280 280 280 215 154 250 250 250 195 142 290 290 290 240 165 300 300 300 250 170
kW 224 224 224 172 123 200 200 200 156 114 232 232 232 192 132 240 240 240 200 136
46.2 VL12 kVA 315 315 300 260 187 276 276 260 230 170 327 327 310 285 200 341 341 325 300 208
kW 252 252 240 208 150 221 221 208 184 136 262 262 248 228 160 273 273 260 240 166

Ratings 60 Hz - 1800 R.P.M.


kVA / kW - P.F. = 0.8
Duty/T°C Continuous duty/40°C Continuous duty/40°C Stand-by/40°C Stand-by/27°C
Class/T°K H/125°K F/105°K H/150°K H/163°K
Phase 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph. 3 ph. 1 ph.
Y 380V 416V 440V 480V ∆∆ 380V 416V 440V 480V ∆∆ 380V 416V 440V 480V ∆∆ 380V 416V 440V 480V ∆∆
∆ 220V 240V 240V 220V 240V 240V 220V 240V 240V 220V 240V 240V
YY 208V 220V 240V 208V 220V 240V 208V 220V 240V 208V 220V 240V
46.2 M3 kVA 192 205 220 228 128 177 189 198 210 119 203 219 228 244 136 211 225 237 255 141
kW 154 164 176 182 102 142 151 158 168 95 162 175 182 195 109 169 180 190 204 113
46.2 M5 kVA 205 219 230 250 136 190 203 211 225 126 219 235 245 262 145 227 242 252 273 151
kW 164 175 184 200 109 152 162 169 180 101 175 188 196 210 116 182 194 202 218 121
46.2 L6 kVA 257 276 289 300 173 239 255 265 278 160 276 295 308 324 184 285 304 317 337 192
kW 206 221 231 240 138 191 204 212 222 128 221 236 246 259 147 228 243 254 270 154
46.2 L9 kVA 296 316 328 344 197 273 291 302 302 182 313 338 351 357 209 326 348 366 375 220
kW 237 253 262 275 158 218 233 242 242 146 250 270 281 286 167 261 278 293 300 176
46.2 VL12 kVA 333 357 372 381 220 309 329 341 347 200 359 383 397 412 235 370 399 415 429 243
kW 266 286 298 305 176 247 263 273 278 160 287 306 318 330 188 296 319 332 343 194

Electric Power Generation 3


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Efficiencies 400 V - 50 Hz (P.F.: 1) (P.F.: 0.8)


LSA 46.2 M3 LSA 46.2 L9
96% 96% 95.3 P.F. : 1
94.6 94.6 P.F. : 1 95.4
94.9 94.9 95.2
94.5 94
94
93 P.F. : 0.8
93.5 93.5
92.8 92.5 91.7 P.F. : 0.8 92.7
92 92 92.2
92
91.3 91.2
90 90
90.8

88 88
20 40 60 80 100 120 140 160 180 200 220kVA 40 80 120 160 200 240 280 320kVA

LSA 46.2 M5 LSA 46.2 VL12


95.7 P.F. : 1
96% 96%
95 P.F. : 1 95.7 95.7
94.8 95.2 95.2
94 94.8 94 93.7 P.F. : 0.8
P.F. : 0.8 93.9 94.1
92.4 93.5
93.2 92.3
92.3 93
92 92
92 91.6
91.2
90 90

88 88
20 40 60 80 100 120 140 160 180 200 220kVA 40 80 120 160 200 240 280 320 360kVA

LSA 46.2 L6
96% P.F. : 1
95
94.9 95.2 94.8
94
93.3 92.4 P.F. : 0.8
92.5 93.1
92
92
91.4
90

88
40 80 120 160 200 240 280kVA

Reactances (%). Time constants (ms) - Class H / 400 V


M3 M5 L6 L9 VL12
Kcc Short-circuit ratio 0.44 0.45 0.41 0.48 0.5
Xd Direct-axis synchro. reactance unsaturated 312 301 327 294 273
Xq Quadrature-axis synchro. reactance unsaturated 187 180 196 176 164
T’do No-load transient time constant 1971 2042 2105 2175 2253
X’d Direct-axis transient reactance saturated 15.8 14.7 15.5 13.5 12.1
T’d Short-circuit transient time constant 100 100 100 100 100
X”d Direct-axis subtransient reactance saturated 9.5 8.8 9.3 8.1 7.2
T”d Subtransient time constant 10 10 10 10 10
X”q Quadrature-axis subtransient reactance saturated 11.8 10.9 11.5 10 8.9
Xo Zero sequence reactance unsaturated 0.5 0.8 0.7 0.7 0.5
X2 Negative sequence reactance saturated 10.6 9.9 10.4 9.1 8.1
Ta Armature time constant 15 15 15 15 15
Other class H/400 V data
io (A) No-load excitation current (SHUNT/AREP or PMG) 1 1 1 1.1 1
ic (A) On-load excitation current (SHUNT/AREP or PMG) 3.9 3.7 4 3.9 3.4
uc (V) On-load excitation voltage (SHUNT/AREP or PMG) 33 32 34 33 33
ms Response time (∆U = 20% transient) 500 500 500 500 500
kVA Start (∆U = 20% cont. or 50% trans.) SHUNT 340 397 462 538 694
kVA Start (∆U = 20% cont. or 50% trans.) AREP 371 434 504 583 760
% Transient ∆U (on-load 4/4) SHUNT - P.F.: 0.8 LAG 16.2 15.4 15.9 14.6 12.9
% Transient ∆U (on-load 4/4) AREP - P.F.: 0.8 LAG 14.3 13.7 14.1 13 11.4
W No-load losses 2810 3040 3690 4340 4800
W Heat dissipation 12900 13180 16400 16810 16730

4 Electric Power Generation


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Transient voltage variation 400V - 50 Hz


Load application (SHUNT excitation) Load application (AREP or PMG excitation)
M3
25 % 25 % M3
M5
M5
L6
20 20
L6
L9
% Voltage dip

% Voltage dip
L9
15 VL12 15
VL12

10 10

5 5

0 0
0 50 100 150 200 250 300 350 kVA 0 50 100 150 200 250 300 350 kVA
kVA at φ 0.8 power factor kVA at φ 0.8 power factor

Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation)


M3 M5 M3 M5
25% 25%
L6 L6

20 20
L9 L9
% Voltage rise

% Voltage rise

15 VL12 15 VL12

10 10

5 5

0 0
0 50 100 150 200 250 300 350 kVA 0 50 100 150 200 250 300 350 kVA
kVA at φ 0.8 power factor kVA at φ 0.8 power factor

Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation)


M3 M5 L6 L9 VL12 M3 M5 L6 L9 VL12
30% 30%

25 25
% Voltage dip

20 20
% Voltage dip

15 15

12%
10 10

5 5

0 0
0 100 200 300 400 500 600 700 800kVA 0 100 200 300 400 500 600 700 800 900kVA
229
kVA at φ 0.6 power factor locked rotor kVA at φ 0.6 power factor locked rotor

1) For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
Calculation example for a different P.F. other than 0.6: Starter motor kVA calculated at 0.4 P.F. = 200 kVA
➤ Sin P.F. 0.4 = 0.9165 ➤ K = 1.145 ➤ kVA corrected = 229 kVA ➤ Voltage dip corresponding to VL12 = 12%.
2) For voltages other than 400V (Y), 230V (D) at 50 Hz, then kVA must be multiplied by (400/U)2 or (230/U)2.

Electric Power Generation 5


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Efficiencies 480 V - 60 Hz (P.F.: 1) (P.F.: 0.8)


LSA 46.2 M3 LSA 46.2 L9
96% 96% 95.3 P.F. : 1
94.7 P.F. : 1
95.2 95.2
94.8 94.6 94.4
94 94.2
94 93.3 P.F. : 0.8
93.6
92.6 92.7 92.1 P.F. : 0.8 93.2 93
92 92
91.7
91.1 91
90 90 90.2
90

88 88
40 80 120 160 200 240 280kVA 60 100 140 180 220 260 300 340 380kVA

LSA 46.2 M5 LSA 46.2 VL12


96% 96% 95.7 P.F. : 1
P.F. : 1 95.6
95 95.5
95 93.9 P.F. : 0.8
94.9 94.6
94 94.4 94
94.1
92.7 P.F. : 0.8 93.6 93.8
93 93.2
92 92.4 92
91.3 91.2 90.5
90 90.3 90

88 88
40 80 120 160 200 240 280kVA 60 100 140 180 220 260 300 340 380 420kVA

LSA 46.2 L6
96% P.F. : 1
95
95 94.9
94 94.3
92.8 P.F. : 0.8
93 93.2
92 92.5
91.1

90 90.2

88
60 100 140 180 220 260 300 340kVA

Reactances (%). Time constants (ms) - Class H / 480 V


M3 M5 L6 L9 VL12
Kcc Short-circuit ratio 0.41 0.43 0.41 0.47 0.5
Xd Direct-axis synchro. reactance unsaturated 329 314 327 300 275
Xq Quadrature-axis synchro. reactance unsaturated 197 188 196 180 165
T’do No-load transient time constant 1971 2042 2105 2175 2253
X’d Direct-axis transient reactance saturated 16.7 15.3 15.5 13.8 12.2
T’d Short-circuit transient time constant 100 100 100 100 100
X”d Direct-axis subtransient reactance saturated 10 9.2 9.3 8.2 7.3
T”d Subtransient time constant 10 10 10 10 10
X”q Quadrature-axis subtransient reactance saturated 12.4 11.4 11.5 10.2 9
Xo Zero sequence reactance unsaturated 0.5 0.5 0.6 0.4 0.4
X2 Negative sequence reactance saturated 11.2 10.3 10.4 9.3 8.2
Ta Armature time constant 15 15 15 15 15
Other class H/480 V data
io (A) No-load excitation current (SHUNT/AREP or PMG) 1 1 1 1.1 1
ic (A) On-load excitation current (SHUNT/AREP or PMG) 4 3.8 3.9 3.8 3.4
uc (V) On-load excitation voltage (SHUNT/AREP or PMG) 34 32 33 33 33
ms Response time (∆U = 20% transient) 500 500 500 500 500
kVA Start (∆U = 20% cont. or 50% trans.) SHUNT 420 496 575 673 867
kVA Start (∆U = 20% cont. or 50% trans.) AREP 461 540 629 732 953
% Transient ∆U (on-load 4/4) SHUNT - P.F.: 0.8 LAG 16.7 15.8 15.9 14.8 13
% Transient ∆U (on-load 4/4) AREP - P.F.: 0.8 LAG 14.8 14.1 14.1 13.1 11.5
W No-load losses 4180 4500 5530 6430 7090
W Heat dissipation 15570 15680 18500 19690 19510

6 Electric Power Generation


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Transient voltage variation 480V - 60 Hz

Load application (SHUNT excitation) Load application (AREP or PMG excitation)


M3
25 % 25 % M3
M5
M5

20 L6 20
L6
L9
% Voltage dip

% Voltage dip
L9
15 15
VL12
VL12

10 10

5 5

0 0
0 50 100 150 200 250 300 350 400 kVA 0 50 100 150 200 250 300 350 400 kVA
kVA at φ 0.8 power factor kVA at φ 0.8 power factor

Load rejection (SHUNT excitation) Load rejection (AREP or PMG excitation)


M3 M5 M3 M5
25% 25%

L6 L6
20 20
% Voltage rise

% Voltage rise

L9 L9

15 15
VL12 VL12

10 10

5 5

0 0
0 50 100 150 200 250 300 350 400 kVA 0 50 100 150 200 250 300 350 400 kVA
kVA at φ 0.8 power factor kVA at φ 0.8 power factor

Motor starting (SHUNT excitation) Motor starting (AREP or PMG excitation)


M3 M5 L6 L9 VL12 M3 M5 L6 L9 VL12
30% 30%

25 25

20 20
% Voltage dip

% Voltage dip

15 15

10 10
10%

5 5

0 0
0 100 200 300 400 500 600 700 800 900 kVA 0 100 200 300 400 500 600 700 800 900 10001100kVA
229 kVA at φ 0.6 power factor locked rotor kVA at φ 0.6 power factor locked rotor

1) For a starting P.F. other than 0.6, the starting kVA must be multiplied by K = Sine P.F. / 0.8
Calculation example for a different P.F. other than 0.6: Starter motor kVA calculated at 0.4 P.F. = 200 kVA
➤ Sin P.F. 0.4 = 0.9165 ➤ K = 1.145 ➤ kVA corrected = 229 kVA ➤ Voltage dip corresponding to VL12 = 10%.
2) For voltages other than 480V (Y), 277V (D), 240V (YY) at 60 Hz, then kVA must be multiplied by (480/U)2 or (277/U)2 or (240/U)2.

Electric Power Generation 7


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

3-phase short-circuit curves at no load and rated speed (star connection Y)

10000

Symmetrical
LSA 46.2 M3
Asymmetrical

1000
Current (A)

AREP or PMG

100

SHUNT

10
1 10 100 1000 10000 time (ms)

10000

LSA 46.2 M5 Symmetrical


Asymmetrical

1000
Current (A)

AREP or PMG

100

SHUNT

10
1 10 100 1000 10000 time (ms)

10000

Symmetrical
LSA 46.2 L6 Asymmetrical

1000
AREP or PMG
Current (A)

100

SHUNT
10
1 10 100 1000 10000 time (ms)

Influence due to connection


Curves shown are for star (Y) connection.
For other connections, use the following multiplication factors:
- Series delta : current value x 1.732 - Parallel star : current value x 2

8 Electric Power Generation


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

3-phase short-circuit curves at no load and rated speed (star connection Y)

10000

LSA 46.2 L9 Symmetrical


Asymmetrical
AREP or PMG
1000
Current (A)

100

SHUNT

10
1 10 100 1000 10000 time (ms)

10000

Symmetrical
LSA 46.2 VL12
Asymmetrical
AREP or PMG
1000
Current (A)

100

SHUNT

10
1 10 100 1000 10000 time (ms)

3-phase 2-phase L/L 1-phase L/N


Influence due to short-circuit
Curves are based on a three-phase Instantaneous (max.) 1 0.87 1.3
short-circuit. Continuous 1 1.5 2.2
For other types of short-circuit,
Maximum duration (AREP/PMG) 10 sec. 5 sec. 2 sec.
use the following multiplication factors.

Electric Power Generation 9


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Single bearing dimensions

L
Access to terminals
LB
568 Optional cable
AH Xg 566 33 Access to regulator 15° output
CF
13 Standard cable
output

485
PMG optional
- 0,050
Ø BX - 0,100
Ø N - 0,127

765
0

Ø 235
ØP

S DIA. Qty 12 as

280 - 1
0
Ø 512 shown on Ø M Ø 206
77

17
AIR 80
AIR OUTLET 2 holes INLET 457
235
185 Ø 21 170 527
6 Access to rotating diodes
6 C Y DIA, Qty X Eq. Sp. on Ø U.

Dimensions (mm) and weight Coupling


Type L without PMG LB Xg C Weight (kg) Flex plate 11 1/2 14
LSA 46.2 M3 973 920 460 429 585 Flange S.A.E 3 X
LSA 46.2 M5 973 920 470 429 625 Flange S.A.E 2 X
LSA 46.2 L6 1083 1030 460 429 710 Flange S.A.E 1 X X
LSA 46.2 L9 1083 1030 485 429 775 Flange S.A.E 1/2 X
LSA 46.2 VL12 1175 1130 530 525 895

Flange (mm) Flex plate (mm)


S.A.E. P N M S R CF S.A.E. BX U X Y AH
3 575*/623 409.575 428.625 11 345*/368 24*/17 11 1/2 352.42 333.38 8 11 39.6
2 575*/623 447.675 466.725 11 345*/368 24*/17 14 466.72 438.15 8 14 25.4
1 575*/623 511.175 530.225 12 345*/368 24*/17
1/2 651 584.2 619.125 14.5 382 17 * : dimensions LSA 46.2 M

Torsional analysis data


Xr
Ø 100

Ø 120
Ø 115

Ø 115

Ø 110

Ø 104(46.2 M)
Ø 75
Ø 75

Ø 106(46.2 L)
Lr

Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2)
Flange S.A.E. 11 1/2 Flange S.A.E. 14
Type Xr Lr M J Xr Lr M J
LSA 46.2 M3 422 935 229 1.78 407 935 229.4 1.909
LSA 46.2 M5 434 935 245 1.948 419 935 245.3 2.077
LSA 46.2 L6 466 1045 278 2.329 451 1045 278.8 2.458
LSA 46.2 L9 485 1045 304.3 2.605 474 1045 304.9 2.724
LSA 46.2 VL12 540 1145 357 3.1 529 1145 357.6 3.216

NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy-
Somer site, 3D drawing files are available upon request.

10 Electric Power Generation


Low Voltage Alternators - 4 pole
LSA 46.2 - 180 to 315 kVA - 50 Hz / 228 to 381 kVA - 60 Hz

Two bearing dimensions


L
Access to terminals
LB 568 Optional cable
105 Xg 566 33 Access to regulator 15° output
20
1 hole M20x42
Standard cable
output

485
PMG optional
Ø 511,175 - 0,127

12

765
+ 0,030
Ø 75 + 0,011
0

Ø 235
ØP

280 - 1
0
20
Ø 512
79,5
77

17
B 80
AIR OUTLET AIR Access to 457
145 BB INLET rotating diodes 527
6 C 6 holes Ø 21 235
M10 DIA, Qty 12 Eq. as shown
on Ø 530,225

Dimensions (mm) and weight


Type L without PMG LB P C BB B R Xg Weight (kg)
LSA 46.2 M3 985 880 575 389 418 368 345 400 570
LSA 46.2 M5 985 880 575 389 418 368 345 410 615
LSA 46.2 L6 1095 990 623 389 418 368 368 430 705
LSA 46.2 L9 1095 990 623 389 418 368 368 455 770
LSA 46.2 VL12 1195 1090 623 485 610 560 368 500 885

Torsional analysis data Xr

105
Ø 120

Ø 115

Ø 110
Ø 115

Ø 104(46.2 M)
Ø 75

Ø 80

Ø 75
Ø 92

Ø 106(46.2 L)
Lr

Centre of gravity: Xr (mm), Rotor length: Lr (mm), Weight: M (kg), Moment of inertia: J (kgm2): (4J = MD2)
Type Xr Lr M J
LSA 46.2 M3 395 955 199.9 1.57
LSA 46.2 M5 404 955 215.8 1.738
LSA 46.2 L6 436 1065 247.6 2.109
LSA 46.2 L9 453 1065 273.7 2.385
LSA 46.2 VL12 502 1165 323.8 2.845

NOTE : Dimensions are for information only and may be subject to modifications. Contractuel 2D drawings can be downloaded from the Leroy-
Somer site, 3D drawing files are available upon request.

Electric Power Generation 11


www.emersonindustrial.com

© Emerson 2014. The information contained in this brochure is for guidance only and does not
form part of any contract. The accuracy cannot be guaranteed as Emerson have an ongoing
process of development and reserve the right to change the specification of their products
without notice.

Moteurs Leroy-Somer SAS. Headquarters: Bd Marcellin Leroy, CS 10015, 16915 Angoulême


Cedex 9, France. Share Capital: 65 800 512 €, RCS Angoulême 338 567 258.

3790 en - 2015.04 / i

You might also like