Cryogenic Standard Tanks
Cryogenic Standard Tanks
Cryogenic Standard Tanks
Contents.
3 Introduction 4 Standard vacuum-insulated tanks 5 Quality standards for cryogenic tanks
Standards for enhanced quality
6 Technical data - tanks for air gases LIN, LOX, LAR 7 Technical data - tanks for carbon dioxide 8 Features
Highly effective operation Easy operation Safety Ergonomical position of controls and instruments Special equipment for vaporizers
10 Flow diagram - tanks for nitrogen, oxygen, argon 11 Flow diagram - tanks for carbon dioxide 12 Contact
Production facilities Product range
Introduction.
To an increasing extent, industrial gases such as oxygen, nitrogen and argon are delivered to customers in liquid form at cryogenic temperatures and stored by the customer in tanks before further use. The pressure ratings and sizes of these tanks have been standardized in accordance with the requirements of distribution logistics and economical series production.
Standard carbon dioxide tanks are very similar to the tanks for airgases. As a function of the application and customers request you have here the choice between an inner vessel either manufactured from a low temperature resistant austenitic steel or a ne grain carbon steel. The insulation system is equal to the system which is used for the air gas tanks. CO2-tanks, equipped with an inner vessel made out of a low temperature resistant austenitic steel can therefore also be used as multi-purpose storage for other industrial gases. Linde owns long standing experience in handling other liqueed gases such as for example LNG and hydrogen. Tanks for these gases are engineered and manufactured according to customers specications, therefore quotations will be elaborated from case to case.
Standards for enhanced quality Depending on the requirements the tanks are available in two enhanced quality degrees:
Quality degree
Technical detail
Applications
HQ Degree for media with purity >5.0 Pipes pickled High demands in semiconductor Cryogenic valves with bellows, industry and research Inner vessel pickled
IQ Degree for aggressive industrial environment Type with inner vessel in austenitic stainless steel according to Linde standard Cryogenic valves with stuffing box Aggressive environment
18 bar 36 bar
80,360 76,340
Pressure stage 18 bar, filling ratio 95 %, 1 bar 36 bar, filling ratio 90 %, 1 bar
61,680
Boil-off rate V, 1 bar, 15C A.T. referred to total capacity vacuum < 2 x 10 -2 mbar
0.21
Discharge capacity with standard pressure build-up vaporizer at 0,7 x MAWP and 8 hours operating time pressure stage 18 bar m3/h (1 bar, 15C) LIN m3/h (1 bar, 15C) LOX m3/h (1 bar, 15C) LAR 36 bar m3/h (1 bar, 15C) LIN m3/h (1 bar, 15C) LOX m3/h (1 bar, 15C) LAR
600
Capacity of one safety valve at 1.1 x MAWP/cold condition pressure stage 18 bar kg/h LIN kg/h LOX kg/h LAR 36 bar kg/h LIN kg/h LOX kg/h LAR
1,070
Insulation
insulating powder (perlite), vacuum < 5 x 10-2 bar (tank in operation) status of delivery: 5 mbar
Main material
inner vessel: low temperature resistant austenitic steel outer vessel: carbon steel
Main dimensions
1,600 4,200
1,600 7,200
2,000 7,500
2,400 8,400
2,400 11,600
3,000 11,700
Weight empty, kg
18 bar 36 bar
type type
2,510 2,600
4,910 5,220
5,940 7,180
9,840 12,310
13,920 17,090
19,300 24,570
23,370 30,260
29,650
3,160 2,940
6,365 5,920
11,535 10,730
20,355 18,930
30,205 28,090
49,020 45,590
61,620 57,310
kg CO2
3,120
6,280
11,370
20,065
29,780
48,330
60,740
Boil-off rate V, 1 bar, 15C A.T. referred to total capacity vacuum < 2 x 10 -2 mbar
%/d CO2
0.22
0.19
0.14
0.10
0.10
0.07
0.06
Discharge capacity with standard pressure build-up vaporizer at 0.7 x MAWP and 8 hours operating time pressure stage 22 bar
70
140
140
280
280
Capacity of one safety valve at 1.1 x MAWP/cold condition pressure stage 22 bar
kg/h, CO2
970
Insulation
insulating powder (perlite), vacuum < 5 x 10-2 bar (tank in operation) status of delivery: 5 mbar
Main material
inner vessel: low temp. resistant austenitic steel outer vessel: carbon steel
Main dimensions
1,600 4,200
1,600 7,200
2,000 7,500
2,400 8,400
2,400 11,600
3,000 11,700
3,000 14,200
Weight empty, kg
22 bar
Type
2,510
4,910
6,300
10,250
14,500
20,500
24,800
Features.
Highly effective operation Two service valves provide an exchange possibility for the lling valves even if the tank is lled. Integrated pressure built-up vaporizer for standard discharge capacities (service valves see ow diagrams: valve 2 pressure built-up and valve 13 gas shut-off).
Easy operation All valves required for operation are set in one line.
Safety In case that the safety valves will release product, the medium will be blown off to a safe place.
Ergonomical position of controls and instruments The tank controls and instruments are set in two lines. Operation line: operation controls and instruments Service line: service controls and instruments The operation controls and instruments can be operated by the user. A white handwheel is xed on top of this instruments and will be used for lling or extraction. The service controls and instruments will be used by trained employees of the gas supplier only. These valves are marked with a green handwheel.
Special equipment for vaporizers Tanks from 3,000 up to 30,000 litre are equipped with brackets for a clip-on vaporizer.
Type
L 40-2 F2,5
55
L40-4 F2,5
110
L40-8 F2,5
150
*1) The capacity is based on an ambient temperature of 20C, 70 % rel. humidity, 15C temperature difference between ambient and gas outlet temperature at a continuous 8-hours-operation.
10
LI(T)
11
LI(T)
The range of products comprises: Petrochemical plants LNG and natural gas processing plants Synthesis gas plants Hydrogen plants Gas processing plants Adsorption plants Air separation plants Cryogenic plants Biotechnological plants Furnaces for petrochemical plants and reneries
More than 3,800 plants worldwide document the leading position of the Engineering Division in international plant construction.
P/3.3.e/09
Production facilities.
We at the Linde Schalchen Plant are located 90 km east of Munich, Germany and cover a total site area of approx. 200,000 m. Our 750 engineers and skilled workers design and manufacture components and complete modules for the application in process plants. Backed up by more than 100 years of production know-how, highly developed plant modules are manufactured. Our innovative technologies and our competitiveness open the door to participation in prestigious plant projects world-wide. We provide complete services on field installation and operation. A specialized service crew is available for immediate and professional repair services.
Product range.
Aluminium plate-n heat exchangers as single units or as manifolded assemblies Coldboxes with aluminium plate-n heat exchangers, columns and vessels Coil-wound heat exchangers and isothermal reactors for chemical and petro- chemical plants Columns and pressure vessels in aluminium for cryogenic plants Spiral-welded pipes in aluminium Storage tanks for liqueed gases Steam-heated waterbath vaporizers as well as air-heated vaporisers for liqueed gases
For further informations please contact: Linde AG Engineering Division, Schalchen Plant Carl-von-Linde-Str. 15, D-83342 Tacherting, Germany Phone +49.8621.85-6434 Fax +49.8621.85-6622 E-Mail: plantcomponents@linde-le.com Website: www.linde-plantcomponents.com