En 50288
En 50288
En 50288
www.caledonian-tech.net sales@caledonian-tech.net
APPLICATION
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply. Recommended for indoor and outerdoor installation, on racks, trays, in conduits, in dry and wet locations; not for direct buiral. Recommended for use as fire protection messure for people and important material assets.
STANDARDS
Basic design to EN 50288-7
FIRE PERFORMANCE
Fire Resistant Circuit Integrity System Circuit Integrity IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180); CEI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)
DIN 4102-12, E30 depending on lay system EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE Flame Retardance (Single Vertical 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); Wire Test) CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; Reduced Fire Propagation (Vertically-mounted bundled wires VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); & cable test) CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; Halogen Free CEI 20-37/2-1 ; BS 6425-1* IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; No Corrosive Gas Emission CEI 20-37/2-2 ; BS 6425-2*
ADDISON
57
ADDISON
Minimum Smoke Emission No Toxic gases IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* NES 02-713; NF C 20-454
VOLTAGE RATING
300V
CABLE CONSTRUCTION
Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2. Insulation: Extruded cross-linked XLPE compound, EN 50290. 2-29. Fire Barrier: Mica tape. Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm Binder tape: PETP transparent tape. Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm. Inner Sheath: LSZH compound. Amouring: Double steel tape armour. Outer Sheath: LSZH compound as per EN 50290-2-27. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.
COLOUR CODE
Insulation: Red / White Inner Sheath: Black Outer Sheath: Orange
Electrical PROPERTIES
Conductor Area Size Insulation thickness (nominal) Conductor resistance (20C) Insulation resistance (20C) Mutual Capacitance (1 kHz) Capacitance unbalance(1 kHz) Inductance mm 2 mm /km M.km(Min.) pF/m(Max.) pF/500 m (Max.) mH/km (Max.) 0.88 0.6 21.4 5000 115 500 1
58
Caledonian
Caledonian
L / R (ratio) (max.) Operating voltage Urms Test Voltage Core to Core Core to Screen
www.caledonian-tech.net sales@caledonian-tech.net
H/ V V V
CONSTRUCTION PARAMETERS
RE-m2X(St)HSTAH Caledonian Cable Code Nominal Nominal Nominal No. of Nominal Nominal Approx. Pairs Inner Steel Tape Outer Overall x2xCross Insulation Sheath Weight Armour Sheath Section Thickness Thickness Thickness Thickness Diameter No.x2xmm2 RE-m2X(St)HSTAH 1P0.88 1x2x0.88
300V
EN 50288-7
W
mm2 0.6
mm 1.0
mm 0.2
mm 1.4
mm 13.5
kg/km
300
Note : Other conductor sizes & core configurations are available upon request.
N
Standard
Rated Voltage
Reduced Fire Propagation Flame Retardancy NF C32-070-2.2(C1) NF C32-070-2.1(C2) IEC60332-3-24 IEC60332-1-2/EN50265-2-1 EN50266-2-4
Zero
ADDISON
59