MFJ 4712
MFJ 4712
MFJ 4712
Instruction Manual
DC / RF
Instruction Manual
INSTALLATION
1. The MFJ-4712 external unit can be located at any convenient location using the U-Bolt package included with the unit. Any mast up to 1 inches in diameter will fit. 2. Connect your Antennas to the SO-239 coax connectors on the MFJ-4712 external unit labeled Antenna 1 and Antenna 2. 3. Connect your Transmitter to the RF IN/OUT coaxial connector on the MFJ-4712RC Remote Control using a 50-ohm coaxial cable. This is the RF signal input connector. (See Figure 1) 4. Connect a standard DC 2.1 mm plug to the DC IN/OUT jack on the MFJ4712RC Remote Control. This is your DC voltage input connector. The supply must be capable of supplying 300mA continuous at 12-15 volts DC. This unit is polarity sensitive. It requires the following power connection:
The sleeve is negative, and can be grounded or floated at the power supply. The center pin is positive, and MUST be ground isolated. 5. Connect the feedline coax that you will be running to your antennas to the RF/DC OUT/IN coaxial connector on the MFJ-4712RC Remote Control using 50-ohm coaxial cable. This is your RF signal and DC power. The MFJ-4712 external unit will recover the RF and DC signals. 6. Connect the feedline coax connected to the RF/DC OUT/IN coaxial connector on the MFJ-4712RC Remote Control to the Transmitter SO-239 coax connector on the MFJ-4712 external unit.
Instruction Manual
OPERATION
1. Slide the Selector Switch to choose the desired antenna. The switch positions are numbered on the 4712RC. When the DC is ON, Antenna 2 is selected. When the DC is OFF, Antenna 1 is selected. Unused inputs are grounded. 2. Once the antenna is selected, you may transmit into the selected antenna.
IMPORTANT:
NEVER switch antennas with RF power applied to the Master feedline. Damage to the switching contacts may result from hot-switching.
TECHNICAL ASSISTANCE
If you have any problem with this unit first check the appropriate section of this manual. If the manual does not reference your problem or reading the manual does not solve your problem, you may call MFJ Technical Service at 662-3230549 or the MFJ Factory at 662-323-5869. You will be best helped if you have your unit, manual and all information on your station handy so you can answer any questions the technicians may ask. You can also send questions by mail to MFJ Enterprises, Inc., 300 Industrial Park Road, Starkville, MS 39759; by Facsimile (FAX) to 662-323-6551; or by email to techinfo@mfjenterprises.com. Send a complete description of your problem, an explanation of exactly how you are using your unit, and a complete description of your station.
NOTES