Prisma Med Schneider Electric or Switchboard
Prisma Med Schneider Electric or Switchboard
Prisma Med Schneider Electric or Switchboard
)
An adaptable solution
meeting all standards
Isolated power solutions for operating theatres
5
A power distribution solution to meet the needs of all users.
The supervision
personnel
The maintenance
personnel
The surgeon
The nurse
6
A monitoring system
Isolated power solutions for operating theatres
Reliable information is needed to ensure the satisfactory operation of
operating theatres. The monitoring system informs in real time and allows
making the appropriate decisions in case of unexpected events.
This monitoring system makes it possible, with the basic signalling panel in the operating room,
to have information concerning the alarms generated by the electrical installation.
Monitoring system for the Classic solution
Access to
real-time alarms,
environment
data, and event
traceability
Classic solution
Basic
signalling
panel
Insulation
fault
Electrical
fault
PC Head
Nurse
Insulation
fault
Electrical
fault
Basic
signalling
panel
Operating room 1 Operating room 2
With a reliable power supply and a complete,
automated monitoring and control system,
we can stay entirely focused on the patient.
8
Level of information
Simultaneous display of all operating rooms data
Temperature, relative humidity, and pressure
Medical gas states
Electrical and insulation fault alarms
Display of each operating room data
Temperature, relative humidity, and pressure
Medical gas states
Electrical and insulation fault alarms
List of events with dates
Display of current alarms
UPS remaining time during emergency mode
Min and max threshold alarms for temperature and relative
humidity settings
Display of temperature, pressure, and relative humidity curves
Event report edition (Excel
12
Single-phase
isolation transformers
Medical locations and operating theatres in particular are
environments in which patient safety and the quality and continuity of
power are of prime importance.
Isolation transformer specications
Schneider Electric offers made in
Romania isolation transformers
for electrical circuits subject to the IT system
and in compliance with the IEC 60364-7-710
and IEC 61558-2-15 standards.
For use in medical locations,
short-circuit protection is not acceptable
and the transformer must be able to
withstand overloads. Whenever the internal
temperature and overload current thresholds
recommended by Schneider Electric are
exceeded, alarms are generated.
The patients safety
is ensured by reinforced insulation and a
low leakage current which reduce the risk of
electric shock and prevent unwanted currents
which could disturb sensitive medical
instruments.
The quality and continuity of power
are ensured through technical features which
can limit nuisance tripping of protection
systems and provide a stable electric power
supply for medical equipment.
Thanks to the design,
there are fewer losses and less generated
heat, with no switchboard ventilation and no
routine cleaning required.
Reinforced
insulation
Low leakage
current
No ventilation
Special dry single-phase LV/LV transformers 6.3/8 or 10 kVA
Voltage ratio 230/115-230 V
Frequency 50/60 Hz
Insulation level 1.1 kV
Insulation class H
Temperature rise class F
Short circuit voltage < 3 %
Magnetizing current < 3 %
Inrush current < 12 In
Leakage current between enclosure and frame < 3.5 mA
Leakage current between secondary and frame < 0.5 mA
Earthing system IT
Supplied with or without IP21/IK07 cover, and 1 individual test report
Schneider Electric offers made in Romania transformers for
electrical circuits subject to the isolated power system and in
compliance with the IEC 60364-7-710
and IEC 61558-2-15 standards.
Isolated power solutions for operating theatres
13
Vigilohm IM10-H, IM20-H
insulation monitor devices
Operation
Continuous insulation monitors inject a
direct low-frequency AC voltage into the
network, thus creating an articial leakage
current. An electronic device measures the
network insulation from this current.
When this insulation level is below the user-
selected threshold, a relay switches and
the fault indicator lamp lights. These are
failsafe devices; the output relay is excited
permanently, and de-excited in the event
of an auxiliary voltage failure or an
insulation fault.
Indications include: satisfactory insulation
resistance (green light), drop in insulation
resistance below the fault threshold
(orange light), and earth or injection
connection lost.
Display in eight languages
3
of: insulation
resistance, thresholds, and alarms with
dedicated pop-up windows.
Additional functions with IM20-H
Modbus communication.
Datalog with timestamping of all events.
Transformer management: secondary load
current display (in %), alarm on a threshold
(in % of nominal current), alarm on
temperature through the sensor (bimetal).
1 Failsafe: the relay is deactivated on occurrence of a fault or if the auxiliary supply voltage accidentally fails.
2 Suitable for use in all climates:
b damp heat, equipment not operating (IEC 60068-2-30)
b damp heat, equipment operating (IEC 60068-2-56)
b salt mist (IEC 60068-2-52).
3 English, French, Spanish, Italian, Portuguese, German, Russian, Chinese.
Standards conformance:
UTE C 63-080
IEC 364 chapter 4 & 5, IEC 61557-B
NF C 15-100 paragraph 413 & 532, NF C 15-211
VDE 107, VDE 413-2
Devices dedicated to monitor hospital low-voltage AC
networks with isolated neutral or directly earthed neutral via
a capacitive impedance.
14
Complete insulation
monitoring keeps
patients safe
Vigilohm IM10-H, IM20-H specications
Type of installation to be monitored
LV AC / DC IT systems Phase-to-neutral voltage y 230 V AC +15%
y 100 V DC +15%
Frequency 50/60 Hz
Electrical characteristics
Range for insulation resistance readings 1 k to 10 M
Fault signalling Number of thresholds 1 (password protected)
Thresholds 50 k to 500 k
Response time y 1 s
Device operating test Yes
Failsafe feature
1
As standard
Internal impedance At 50 Hz 110 k
Accuracy 5 %
Output contact Number 1 for IM10-H Insulation alarm
2 for IM20-H Insulation and
transformer alarms
Input contact Voltage supplied 24 V
Transformer bimetal Minimum load 5 mA
Auxiliary voltage of IM10 or IM20 50/60 Hz 110/230 V AC 15 %
Auxiliary supply of alarm supply chain DC 125/250 V DC 15 %
Cable size 0.2 to 2.5 mm
2
Maximum device consumption 12 VA
Measurement voltage 25 V max
Measurement current 0.2 mA
Dielectric strength 4000 V AC / 5500 V DC
Mechanical characteristics
Weight 0.25 kg
Thermoplastic case Mounting Panel mount or DIN rail
Degree of protection Front IP52
Installation Cat. III, pollution 2, moulded case, disconnectable assembly, symmetrical
or embedded
Other characteristics
Temperature range For operation -25 C to +55 C
For storage -40 C to +70 C
Climatic conditions
2
Standards Product IEC 61557-8
Safety IEC 61010-1
Installation IEC 60364-7-710
Isolated power solutions for operating theatres
15
Control and signalling panel
in operating room
A simple signalling panel for monitoring of
insulation and electrical faults.
Basic signalling panel for the
Classic solution
Simple and efcient
Audible and visual alarm for an insulation
or electrical fault (overheating, transformer
overload, or circuit breaker trip)
Test button for the insulation
monitoring system
Audible alarm stoppage
Correct operation indicator
Flush mounted
Antibacterial
Tested with
Anios cleaning
products
Fast and simple access to critical power and environmental data.
Basic signalling panel
Compliant with IEC 61557-8
IEC 61010-1
Tested with
ANIOS products
Dimensions (HxLxD) 170x170x20 mm
Weight 0.5 kg
Supply 24 VDC
Protection degree IP54, IK08
Basic signalling panel specications
16
Galaxy UPS specications
Quality of electric
power supply and
continuity of service
Normal AC supply input
Input voltage (V) 250 V1 to 470 V, three-phase
Normal and bypass AC inputs Separate
Frequency (Hz) 45 66 Hz
Input power factor > .99
THDI < 3% full load
Bypass AC Input
Input voltage range (380 V, 400 V, 415 V) +/- 10%
Frequency 50 Hz/60 Hz +/- 10%
Output
Phase to phase output voltage (V) 380 V/400 V/415 V, three-phase + neutral
Load power factor 0.9
Output frequency 50 or 60 Hz +/- 0.1%
Overload capacity utility operation 125% for 10 minutes; 150% for 60 seconds
Output voltage regulation +/- 1%
Voltage distortion (THD) <2% Phase-to-phase and Phase-to-neutral for non-linear loads
Output voltage tolerance +1% static, +/- 2% at 100% load step
Overall efciency
Efciency at full load (AC-AC) at 100% load Up to 93.5%
ECO mode up to 97%1
Communication and management
Control panel Multifunction LCD, status, and control console
Only available in unitary products
Centralized UPS to support all operating theatres and
intensive care unit.
Cost effective, layout saving solution for
more than three operating theatres, with
mutualization of battery remaining time.
Designed to implement N+1 devices
principle, featuring online technology that fully
isolates and protects against all power quality
disturbances in even the most demanding
environments. High efciency in double
conversion or ECO mode saves valuable
energy costs and a comprehensive range of
options enables it to be highly effectve in
any application
Adapted uninterruptible
power supply
Isolated power solutions for operating theatres
17
Secure electrical distribution
switchboards for operating theatres
Reliability of electrical connections thanks to distribution blocks with spring
terminals, requiring no maintenance
High level of reliability of the electrical installation thanks to full compatibility
between Schneider Electric equipment and distribution blocks
Switchboards tested in accordance with IEC 60364-7-710 and IEC 61439-1
and -2 standards and the EMC standard IEC 60364-4-44.
Prisma P
18
High value-added services
Throughout the world, our Schneider Electric service experts and
our local partners are attentive to your needs and will deliver a
comprehensive and unique service offering.
Expert services
For improved performance
Energy efciency
Installation reliability and safety
Reduced capital expenditure
Reduced power consumption
Reduction in the number of failures
Reduction in downtime and repair time
Training of operation and
maintenance teams
Longer equipment service life
over the entire life cycle of the installation
Installation design
Commissioning
Operating aid
Maintenance and revamping
Energy efciency audit
Customized services
Customer support and online services
Call centres, online diagnosis services, and
technical assistance
Services via Internet: electronic catalogues,
downloadable software, information,
and training
In search of excellence
Schneider Electric conducts an ambitious
innovation, quality, and efciency policy.
Around 5% of turnover is invested in R&D
6500 researchers and developers
A close relationship with our customers
We have a strong international footprint
with more than 100 000 employees in
over 100 countries worldwide. With our
partners, distributors, panel builders,
contractors, and engineering ofces, we
want to establish with you a relationship of
trust and help you achieve an optimal level
of performance.
A strong social commitment
Sustainable development is a key part
of the Schneider Electric strategy. Our
solutions help those without electricity
obtain access to it and favour a reduction
in energy consumption by both industrial
rms and private consumers.
91% of our plants are certied ISO 14001.
The Schneider Electric product
offering complies with all existing
standards worldwide.
Isolated power solutions for operating theatres
19
p Standard features
o Optional features
Classic
Switchboard
Enclosure Basic display in the operating Theatre
p
Cubicle with integral transformer (HxWxD):
2206 x 656 x 450 mm
p
Audible and visual alarm for an insulation or electrical fault
(overheating, transformer overload, feeder circuit breaker trip)
p
Test button for the insulation monitoring system
Panel door
p
Audible alarm mute
p
No door
o
Transparency door
o
Plain door
Insulation transformer
p
6.3 kVA
o
8 kVA
o
10 kVA
Insulation fault location
o
Module XD312-H with 12 toroid
Number of feeders
p
12 Isolated Power System feeders
(1 to 3 outlets by feeder)
p
3 TNS feeders
Local UPS - SMART model
o
8 kVA
o
10 kVA
Centralized UPS - Galaxy model
o
Consult with your local Schneider Electric representative
Our Classic Solution
The isolated power solutions adapt to all hospital sizes, applications,
and requirements. Your Schneider Electric representative will
help you choose the specific options that best meet the needs
of each installation.
Were confdent in specifying these solutions
because each one is pre-tested and
documented from end to end, which makes
our job easier and our customer confdent it
will meet their needs.
Monitoring System
Schneider Electric Industries SAS
Head Ofce
35 rue Joseph Monier
92500 Rueil Malmaison Cedex - France
Tel.: +33 (0)1 41 29 70 00
Design: Global Marketing,
Communications, Strategy, and Design
Make the most of your energy
SM
To find out more, please visit: www.schneider-electric.com
2013 Schneider Electric. Schneider Electric Industries SAS, All Rights Reserved. Schneider Electric, Make the most of your energy, APC, Magelis, Prisma Plus, Smart-UPS, TAC,
Xenta, and Vigilohm are owned by Schneider Electric or its afliated companies in the United States and other countries. All other trademarks are property of their respective owners.
998-2748_GMA-GB_A
Find more information about the
Operating Theatre Solution on:
www.schneider-electric.com
website
tv.schenider-electric.com
Schneider Electric TV website