SF 200 Hardware Deployment Manual
SF 200 Hardware Deployment Manual
SF 200 Hardware Deployment Manual
SF200
Sound Feeding system for shrimp
HARDWARE DEPLOYMENT
GUIDE
Version 1.4
AQ1SystemsPtyLtd2013 page1
SF200HardwareDeploymentGuide
SF200COMPONENTSANDDEPLOYMENT
SF200features
SF200components&specification
Installationandmounting
*
SF200controller
Hydrophone
Radiobasestation
OfficePC
AQ1SoundFeedingSoftwareV1.3
TheSF200Site
Hydrophonedeployment
HydrophoneDeploymentConsiderations
DeploymentRequirements
Considerationforpondswithhighwatervelocities
Howtocalculatewherethemajorityofpelletslandonpondbottominhighwatervelocity
Feedertypeandnumberperpond
Antennainstallation
Electricalinstallation
SF200RoutineServiceRequirements
SF200Controller
Hopper
HopperMotors
Hydrophone
MainsPowerSupply
SF200storingconsiderations
Hopper
Hydrophonecareandstorage
CleaningandstoringtheHydrophones
SF200Controllerwiring
ContactDetails
AQ1SystemsPtyLtd2013 page2
SF200HardwareDeploymentGuide
SF200 COMPONENTS AND DEPLOYMENT
SF200 features
TheSF200istheworldsfirstsensorbasedfeedingcontrolsystemforshrimpfarmers.The
systemusespassiveacousticstoidentifyshrimpfeedingactivityandthenusesthatinformationto
controltemporalfeeddeliveryviatheAQ1Sonicfeedingalgorithm.TheSonicalgorithm
ensuresfeeddeliveredmatchesshrimpappetitesothatallanimalsarefedfullywithoutwaste24
hoursadayifrequired.
Thesystemfeatures:
Ahydrophonesensorthatdeterminesfeedingactivitybymeasuringshrimpfeeding
sounds
Sonicfeedingalgorithmstocontrolfeedingrates
Builttohighgrade(IP66)standardsandeasytomaintain
Cansupportavarietyoffeeders
Cansupportavarietyofenvironmentalsensors
Automatesfeedingdelivery24/7
ImprovesFCR&Growth
Replacesfeedtrays
Minimiseslabour
Eliminateswastefeed
Reducessizevariationatharvest
AQ1SystemsPtyLtd2013 page3
SF200HardwareDeploymentGuide
SF200 components & specification
Figure1SF200overviewdiagram
TheSF200systemconsistsofahydrophone(s),SF200pondsidecontrollerincludingWLAN
communications,WLANbasestationincludingantennas,SF200PCAnalysissoftwarewithAQ1
Sonicfeedingalgorithmsandoptionaldissolvedoxygenandtemperatureprobes.
TheSF200includes:
Astateoftheartcontrollerandcommunicationsplatform
FeedingAnalysisandReportsthatareaccessibleviaawebbrowser
Advancedsoundanalysisalgorithms
Anomnidirectionalhydrophonetoallowaneffectivesamplewithinafeedingzone
AQ1SystemsPtyLtd2013 page4
SF200HardwareDeploymentGuide
Installation and mounting
SF200 controller
EachSF200cantakeinputfromoneortwohydrophones,operateoneortwofeeders(three
phase,singlephaseorlowvoltagetypesviaswitchedrelays)andhas8x420mAinputsfor
environmentalsensorssuchasdissolvedoxygenandtemperature.
AQ1SystemsPtyLtd2013 page5
SF200HardwareDeploymentGuide
Figure2SF200Controller Figure3Antenna
Figure4I/OcircuitboardV1.4
AQ1SystemsPtyLtd2013 page6
SF200HardwareDeploymentGuide
Hydrophone
Figure5Hydrophone
Theprobehasfrequencyresponsespecificallytailoredforshrimpsounds,size6.35cmlengthX
1.9cmdiameter,comesstandardwith40mofelectricallyshieldedcablewithoptionallengthupto
max.150m.
Radio base station
Figure6DirectionalAntenna Figure7Typicalbasestationantenna
Omniordirectionalantennawithinbuiltradiomountedonapoleattheoffice.Heightaboveground
isgenerally310mwithclearlineofsighttoallSF200controllers.Theantennacanbefixedto
existingcommunicationsinfrastructureaftercheckingforpotentialinterference.Rangedepends
onlocalregulatoryrequirements.
AQ1SystemsPtyLtd2013 page7
SF200HardwareDeploymentGuide
Office PC
MinimumcomputerspecificationfortheofficePCis:
Memory 4GB
OperatingSystem Windows7,Windows8,64or32bit
Network Onboard10/100MpsEthernetSupport
Processor IntelCorei3orbetter
HDD 250GBorbetter
MicrosoftExcel Optionalbutrecommendedfordataanalysis
InternetConnection DSLorbetter
AQ1 Sound Feeding Software V1.3
SoundFeedingcontrolsoftwaremanagestheSF200controllerandhydrophonebasedfeedingof
shrimp.Thesystemgeneratesrealtimeviewingandhistoricalreportsofallkeyfeedingindices
thataresentautomaticallyviaemailorcanbedirectlyexported.ItcomesstandardwiththeAQ1
Sonicfeedingalgorithmforthespeciescultured.ItalsocomesstandardwithasimpleTimer
program(hydrophonemonitoringonly)usefulforverysmallshrimpbeforetheydisplaysignificant
feedingsounds.
AQ1SystemsPtyLtd2013 page8
SF200HardwareDeploymentGuide
The SF200 Site
PriortoinstallationanAQ1sitesurveywillbecarriedoutusingtheAQ1sitespecificationformto
establishoptimalsetupparameters.Shrimpgenerallystarttogeneratefeedingsoundsatabout
+3gmsinsize.
Figure8Typicalpond Figure9Hopper
Figure10communicationssetup
Hydrophone deployment
Hydrophonedeploymentapparatusconsistsofafloatattachmentformidwatercolumnplacement
andarubberweightforanchoringtheprobe(extraweightcanbeaddedifrequiredduetohigh
AQ1SystemsPtyLtd2013 page9
SF200HardwareDeploymentGuide
watervelocity).Theslowfoulingrubberprobecomeswithelectricallyshieldedcableandrequires
nocalibrationitshouldbecheckedroutinelyandcleared/wipedofbiofoulingasneeded.
Figure11HydrophoneinPond Figure12Hydrophonewithweight
Hydrophone Deployment Considerations
Ensurethehydrophoneisnotentangledatdeployment(entanglementmaycauseexcessnoise
duetorubbingthatinterfereswithsystemoperation).
TheOmnidirectionalhydrophonesamplesanareawithinthefeedzone.
Thelocationofthehydrophonemustbedownstreamfromthecentreofthefeedingzone
asdeterminedbywaterflowdirectioncreatedbytheaerator(s).
Avoidplacinghydrophonecablenearortraversingmainspowercable,orattachedto
pontoon/jettyorautofeedertominimiseanypotentialelectricalorsoundinterference.
Ifrunningthehydrophonecableacrosspondserviceroads,useaburiedconduit.
Figure13Singlehoppersinglehydrophone Figure14Twinhoppersinglehydrophone
Deployment Requirements
Distanceofhydrophone(s)tonearestaeratormustbe>15m
Distanceofaerator(s)toedgeoffeedingzonemustbe>10m
Radiusoffeedzonemustbesufficientsurfaceareameetfeeddemandofbiomass
numberofshrimpstockedpermetreThiscanbedeterminedaftercompletionofAQ1
AQ1SystemsPtyLtd2013 page10
SF200HardwareDeploymentGuide
sitespecificationform..Alsotheradiusoffeedzoneshouldbegreaterthantheradiusof
thehydrophonedetectionzoneundermostoperationalconditions.
Consideration for ponds with high water velocities
Undercertaincircumstancesifthewatercurrentishighthenitisrecommendedtocalculatethe
besthydrophonepositionbasedonthesinkingspeedofpelletandtheestimatedwatervelocity.
Whenpelletshitthewater,theyaremovedbythepondcurrent.Thehydrophoneshouldbeplaced
onthepondinapproximatelythelocationwherethemajorityofpelletswillreachthebottomofthe
pond.
How to calculate where the majority of pellets land on pond bottom in high water
velocity
1. Firstcalculatehowlongthepelletstaketosinktothebottomwithnocurrent.Ifthedepthof
thepondis150cm,andthepelletssinkat10cm/s,thepelletstake15secondstoreachthe
bottomofthepond.(divideponddepthbysinkrateinseconds).
2. In15seconds,howfarwillthecurrentpushthepellets?Ifthecurrentis22cm/s,thenthe
pelletwillbepushedapproximately3.3m.(multiplycurrentspeedbysinktime).
Feeder type and number per pond
Thenumberofsuitablefeeders(bankorcentrallylocated)anddeploymentmethodisspecificto
thepondsize/configuration,speciesgrownandbiomass(consultAQ1).
GeneralConsiderations(speciesdependant)
L.vannamei:5600,000shrimpperfeeder
nomorethan1500shrimp/mmaximumdensityinthefeedingarea.
P.monodon:2300,000shrimpperfeeder
Nomorethan500shrimp/mmaximumdensityinthefeedingarea.
AQ1SystemsPtyLtd2013 page11
SF200HardwareDeploymentGuide
Antenna installation
Figure15Antennaconsiderations
ExamplediagramKey
A&B:Mandatoryunimpededspacewithdirectlineofsightfrombasestationantenna(A)to
SF200pondantenna(B).BaseStationantenna(A)usuallypositioned310mabovegroundon
pole.SF200antenna(B)shouldbepositioned23maboveground.C:SiteofficewherePC,AQ1
soundfeedingsoftware,radiobasestationresidewithinternetconnection.
D:Pond
E:Maximumdistancefromradiobasestationantenna(A)toSF200antenna(B)nogreaterthan
1km(dependsonlocality)butmaybeextendedwithmodification(consultAQ1)
F:PC
G:LANcablefromPCtoradiobasestation(FA)(nogreaterthan100m)
IMPORTANT:EnsurecorrectalignmentofSF200antennatowardsBaseStationantenna
Figure16Antennabeamdirection
Figure17Officeantennatypicalinstallation
Electrical installation
EachSF200cantakeinputfromtwohydrophones,operatetwofeeders(threephase,singlephase
orlowvoltagetypesviaswitchedrelays)andhas8x420mAinputsforenvironmentalsensors
suchasdissolvedoxygenandtemperature.
AQ1SystemsPtyLtd2013 page12
SF200HardwareDeploymentGuide
IMPORTANT:Allmainspower(110480VAC)connectionsandinstallationMUSTbecarried
outbyaqualifiedelectrician.
SF200 Routine Service Requirements
SF200 Controller
CheckredLEDinsideSF200controller
o ON(intermittentflashing)systemfunctioning
o ON(solid)systemisinrebootmodepleasewait2minutesandifstillON(solid)
pleasecallyourlocalAQ1representative.
Hopper
Makesurepelletscanflowfreelywithnoobstructioninhopperatexitpointintospreader
Hopper Motors
TestmotorfunctionwithTESTbuttonontheSF200controller.Allmotorsconnectedtothe
SF200controllerwillspinforaslongasthebuttonishelddepresseduptoamaximumof
300seconds.Itisrecommendedthattheoperatordisablesthefeedernotundertestatthe
junctionboxwhentestingmotorfunctions.
Getaqualifiedelectriciantocheckwiringandmotorconditionifthesystemisstillnot
operatingcorrectly.
Hydrophone
Monitorbiofoulingonthehydrophoneinitiallyonceperweekandwipecleanwithanon
abrasiveclothorlightbrushasrequiredtokeeprubbersurfaceclean.Adjustfrequencyof
cleaningbasedontherateofbiofoulingexperienced.Biofoulingrateswillvaryfrompond
topond,sitetositeandseasonally.
Whenretrievingahydrophonefromapondpleasedonotuseundueforceasthecablecan
break.Iftheunitbecomesentangledtheobstructionwillneedtoberemovedpriorto
retrieval.
Uponredeploymentcheckpositionissuitableasperdeploymentsection3.1andmakesure
thehydrophoneisrepositionedinthesamespotaftercleaning
Whenthehydrophonecableisrestingonthegrounditmustbelocatedinazerotrafficpoint
andcantmoveorrubontheground.
StopthehydrophonecablefromflappinginthewindatthepolesupportingtheSF200by
tyingthehydrophonecabletothepoleusingcableties,
CoilanysparehydrophonecableatthebaseoftheSF200poleanduseacabletietolockit
intoacoil,andletitlieonthegroundwherehopefullyitwontgetdisturbed.(Reverseone
halfofthecoilbeforecabletyingitthisreducesthepossibilityofelectricalinterference
gettingcoupledinthroughthecoil).
Thehydrophonecablemustnottouchthejettyorotherobjectinthepondbecauseitpicks
upvibrationfromtheHoppermotorandwindcausingthecabletotap.Thecablemustbe
positionedonthebottomofthepondandbeisolatedfromthesesourcesofphysicalnoise
interference.
AQ1SystemsPtyLtd2013 page13
SF200HardwareDeploymentGuide
Noropeshouldflapanywhereunderwateragainstthehydrophonecable.
Theconnectionofthehydrophonetoitsrubberweightanchormustclampfirmlyandnotbe
abletomove,ruborbump
Mains Power Supply
Checkwithamultimeterthatthelowvoltage15VDCsupplyispresentandtheunitis
turnedON.
GetacertifiedelectriciantocheckACisONandstable.
SF200 storing considerations
Storing the SF200 Controller
TheSF200controllershouldbeswitchedoffattheswitchontheunitfirst,andthenthe
mainpowerswitch.
Checktheoringsealsonthedooroftheunitarefreeofdebrisandtheoringisina
serviceablecondition.
Thedooroftheunitshouldbefullyclosedandlatchedwiththekeysupplied
PlaceaplasticUVratedbagovertheantennaandlooselytieitclosedatthebottomwitha
bagtieorsimilar.
Forlongtermdecommissioningitisrecommendedthatthehopperisremovedtoacovered
location.
Hopper
Turnpowertothehopperoffattheswitchbox
Emptyhopperandwipeoutinteriorwitharag.
Dislodgeanypelletscaughtbetweendoserandspreader.
Installacanvasshroudaroundfeedermotorareatohelpminimiserainfalling&water
splashingontothespinnermotor.
Hydrophone care and storage
Cleaning and storing the Hydrophones
Careshouldbetakenwhencleaningthehydrophoneasitisadelicatedeviceanditcan
becomedamagedifitisdroppedorsubjectedtoanyundueknocks.
AQ1SystemsPtyLtd2013 page14
SF200HardwareDeploymentGuide
Thehydrophoneshouldberemovedfromthepondandcleanedwithwarmsoapywater
usinganonabrasiverag.Thisincludesthecableaswell.Thecableandhydrophoneshould
thenberinsedinfreshwaterandplacedinwarmdryplace.
Thehydrophoneanditscableshouldbeinspectedfordamageascutsinthecablewill
renderthedeviceunserviceableaswillcutsonthefaceofthehydrophoneitselfthat
penetratetotheceramicunderlayer.IfindoubtpleasesendimagesofthedamagetoAQ1
Systemsforadvice.
Aftercleaningthecableshouldbelooselyrolledoveryourarmtakingcarenottotwistthe
cable.
Placeabagtiearoundthecableandtieit
Placeasmallpieceofbubblewrap,foamorpieceofragaroundthehydrophonesoasto
protectitfromknocksandsecureitwithsomemaskingtape
Placetheunitinadryverminfreeenvironmentwhilenotinuse.
AQ1SystemsPtyLtd2013 page15
SF200HardwareDeploymentGuide
SF200 Controller wiring
SF200Controller1.4wiring
AQ1SystemsPtyLtd2013 page16
SF200HardwareDeploymentGuide
SF200Controller1.1wiring
AQ1SystemsPtyLtd2013 page17
SF200HardwareDeploymentGuide
Figure20SF200Controllertypicalmounting
Figure21BaseStationantennatypicalmounting
AQ1SystemsPtyLtd2013 page18
SF200HardwareDeploymentGuide
Figure22Mountingplate
AQ1SystemsPtyLtd2013 page19
SF200HardwareDeploymentGuide
Contact Details
ForAustraliaandInternational:
AQ1SystemsPty.Ltd.
POBox4606,BathurstStreetPO.
Hobart,TAS,7000
Australia
Email:info@aq1systems.com
Phone:+61362346677
Fax:+61362346622
ForThailand:
AQ1Systems(Asia)Co.,Ltd.
No.1104/157NobleCube,PattanakarnRoad,
SuanluangDistrict,Bangkok,
Thailand
Phone:+66819830793
ForJapan:
AQ1SystemsPty.Ltd.
#603SkyMansionSeaView
2120Maeda,ShimonosekiCity
Yamaguchiken,
Japan7520997
Phone:+81832336950
Fax:+81832336950
AQ1SystemsPtyLtd2013 page20