Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

MCQ Data Aquisition Board: Preliminary Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

MCQ Data Aquisition Board

Preliminary Datasheet
MCQ Data Acquisition Board
Technical Data Sheet
The MCQ Data Acquisition Board is designed to provide a
complete data acquisition solution for test and
measurement applications and control several kinds of
actuators.
The MCQ Data Acquisition Board can collect data from 8
different sensors with an optional signal conditioning
daughter card called Sensor Board.
The Sensor Board is easily adapted to different sensors
granting the maximum sensor performances and allowing
test automation and control, calibration processes and the
possibility to store all results.
All this features make this Board ideal for OEM applications
Resolution: Max 24-bit
Number of Channels: 8 Max
Max Sampling Rate: from 50 Hz to 2 KHz programmable for each channel.
Data acquisition from your own sensor up to 8 sensors, with Sensor Board.
Ideal for OEM applications.
User interface with 3 push-buttons and 4 LED
Low cost.
Power Supply: 12-36 V AC/DC
USB interface
Modular Architecture
I2C BUS with build-in drivers for:
Sensirion SHTxx series (Temperature/Relative Humidity)
Sensirion SDP600 series (Differential Pressure)
4 digital input (Normally Open)
2- channel PWM for valves and actuator control
2 programmable analog output channels (0-5V) , Max 80 mA
Firmware Update from USB.
Easy integration and communication with all MCQ Instruments products to make Custom Solution for laboratory uses.
485 BUS with open propetary protocol.
Specifications:
www.mcqinst.com 2/10 V 1.1 Preliminary
MCQ Data Acquisition Board
TECHNICAL
SPECIFICATIONS
Input Range - +625 mV, +1.25 V, +2.5 V,
625 mV, 1.25 V, 2.5 V
Number of Channels 8
Sampling Rate from 50 Hz to 2 KHz programmable
for each channel
Power Supply 12-36 V AC/DC
Interfaces 4 digital input (Normally Open)
Other I2C Devices on request
USB PC Interface
485 BUS with open propetary protocol
Analog Output (0 - 5V) , Max 80 mA
2 programmable output analog channels
2 PWM channel for valves and
actuator control
I2C BUS with build-in drivers for:
Sensirion SHTxx series
(Temperature/Relative Humidity)
Sensirion SDP 600 series
(Pressure)
Connectors Slot for custom daughter board
Sensor board
User Interfaces 3 push-function button and 4 LEDs
Output Signal Digital: 485 BUS with open propetary
protocol
Resolution Max 24 Bit
www.mcqinst.com 3/10 V 1.1 Preliminary
1
2
3
4
5
6
7
8
9 10 11
12 13 14 15 16
I
2
C Connector
Reset
Programmable Switch
Programmable Switch
USB Led
Programmable Led
Power Led
System Programming Led
485
Connector
USB
Connector
Flow
Control
Actuators
Connectors
Power
Digital Input Microcontroller Sensor board
connectors
Firmware Update
Connector
17
MCQ Data Acquisition Board
Connections:
The image below illustrates you the interfaces and connections of the Board.
www.mcqinst.com 4/10 V 1.1 Preliminary
MCQ Data Acquisition Board
Digital Input:
4 digital inputs for external communication with external devices or external switches or remotes.
The digital input channels of DATA Acquisition Board are TTL and CMOS compatible.
Digital Input Circuit:

4.7K R1
47K
R3
DVDD_3.3V
4.7K
R2
100pF
C1
100pF
C2
TOMICROPROCESSOR DINX
GND GND
D1 D2
D3
Diode TVS
D4
GND
Connection:

GND
DIN1 +
GND
DIN2 +
GND
DIN3 +
GND
DIN4 +
The digital input circuits have a 10 KOhm pull up resistor to 3.3 Volt, as illustrated in the figure below. This forces the digital
inputs to be normally high, and allows contact closures to be connected directly between the digital input channels and
GND which will pull the channel low when contacts are closed.
Digital Inputs are reverse voltage protected, and protected against over voltage with internal CLAMP DIODES
www.mcqinst.com 5/10 V 1.1 Preliminary
D
I
G
I
T
A
L

I
N
P
U
T

1

+
G
N
D
D
I
G
I
T
A
L

I
N
P
U
T

2

-
G
N
D
D
I
G
I
T
A
L

I
N
P
U
T


3

-
G
N
D
D
I
G
I
T
A
L

I
N
P
U
T

4

-
G
N
D
MCQ Data Acquisition Board
Actuator Input:
Proportional Valve 1 & 2
PWM Output 0-10 V, with PWM frequency selectable from 1 KHz to 20 KHz
Proportional Valve 1 - 2 can be used with any actuator requiring PWM input.
Proportional Valve 1 - 2 can be also used to control solenoid valves (ON-OFF) with
LOW STATE = 0V and HIGH STATE = 10V
Max current for each channel: 150 mA
Analog Output 1 & 2
0 5V Analog Ouput for analog actuators and analog controlled devices (diaphragm pumps and other analog devices)
Analog Outputs can be also used to control low voltage solenoid valves (ON-OFF) with
LOW STATE = 0V and HIGH STATE selectable by user in the range 0-5V
Different upper range is possible upon customer request ( max 10V)
Max current for each channel: 150 mA
www.mcqinst.com 6/10 V 1.1 Preliminary
P
R
O
P
O
R
T
I
O
N
A
L

V
A
L
V
E

1

(
P
W
M
)

-
P
R
O
P
O
R
T
I
O
N
A
L

V
A
L
V
E

1

(
P
W
M
)

+
P
R
O
P
O
R
T
I
O
N
A
L

V
A
L
V
E

2

(
P
W
M
)

-
P
R
O
P
O
R
T
I
O
N
A
L

V
A
L
V
E

2

(
P
W
M
)

+
A
N
A
L
O
G

O
U
T
P
U
T

1

(
P
U
M
P
)

-
A
N
A
L
O
G

O
U
T
P
U
T

1

(
P
U
M
P
)

+
A
N
A
L
O
G

O
U
T
P
U
T

2

(
P
U
M
P
)

-
-A
N
A
L
O
G

O
U
T
P
U
T

2

(
P
U
M
P
)

+
D
C

I
N

2

(
1
2
-
2
4
V
)
D
C

I
N

1

(
1
2
-
2
4
V
)

D
C

I
N

2

(
1
2
-
2
4
V
)
D
C

I
N

1

(
1
2
-
2
4
V
)

MCQ Data Acquisition Board
Power Supply:
The Data Acquisition Board requires a DC supply in the range 12-24 V.
Min current supply: 600 mA.
DC Input is not polarized. Internal Diode Rectifier provides the right polarization.
Power Supply + and - could be connected indifferently to each position of the connector.
Fast DAC Output:
Output non-implemented in the current firmware release. For future use (e.g. sound alarms or piezo actuators).
www.mcqinst.com 7/10 V 1.1 Preliminary
MCQ Data Acquisition Board
BUS RS 485:
Flow Board can assume both MASTER or SLAVE rule in a MASTER/SLAVE environment.
Proprietary BUS protocol provides fast and secure communication between each MCQ Instruments device. Flow Boards,
Acquisition Boards and Gas Blenders can be connected togheter with a maximum number on each bus of 64 devices.
One MASTER is required on each BUS.
MASTER device provides with BUS setup function a scan of the BUS network searching for connected SLAVE devices
(each SLAVE device must have a unique address in the range 11-74, Address 10 is reserved to MASTER device).
Once scan is complete, MASTER device stores in non-volatile memory the bus configuration with addressed and rules. On
restart MASTER will provide BUS monitoring and it will be able to detect a failure of each of the SLAVE device, reporting it
as an alarm. In this case MASTER will continue to communicate with all other remaining devices.
For more information contact support@mcqinst.com
For details of 485 BUS protocol functions, download document Communication Protocol from our website.
www.mcqinst.com 8/10 V 1.1 Preliminary
R
S

4
8
5

-
A
R
S

4
8
5

-
B
D
C

O
U
T

+

(
1
0
V
)
D
C

O
U
T

-
(
1
0
V
)
I2C SCK
GND
VDD 3.3 V
I2C SCL
MCQ Data Acquisition Board
I2C BUS:
User can connect via I2C various sensors using this protocol.
The flow board can supply 3.3V DC with a maximum current of 100 mA
MCQ Instruments periodically develops drivers for various third-part sensors like Pressure sensors, Relative Humidity and
Temperature sensors, etc.
Flow Board actually includes drivers for the following sensors:
1) Sensirion SHTXX series Relative Humidity and Temperature
2) Sensirion SDP600 series Differential Pressure
Other drivers can be developed on request. For more information contact support@mcqinst.com
www.mcqinst.com 9/10 V 1.1 Preliminary
MCQ Data Acquisition Board
MCQ Instruments
MCQ s.r.l.
Via delle Quattro Fontane, 33
00184 - Rome - Italy
Contact
Phone: +39 06.48.47.90
Fax: +39 06.99.33.15.98
info@mcqinst.com
support@mcqinst.com
www.mcqinst.com 10/10 V 1.1 Preliminary

You might also like