LET-400-RDC
MAIN FEATURES
Permanent current up to 400A 1 kVA in 4 ranges.
Built in digital ammeter 0.5% accuracy.
Built in digital timer resolution 1 ms.
Thermal and shortcircuit protection.
Variable AC and DC voltage up to 220V.
Variable auxiliary DC power supply up to 220V.
APPLICATIONS
Test of the I/T curve in primary current relays test.
Primary injection tests.
Test of measurement and protection transformers.
In general, primary injection tests including the
complete loop, such as current transformer ca-
bles, protective relays, and circuit breakers.
DESCRIPTION
The LET-400-RDC is designed to perform most of the primary tests that
are necessary in substations commissioning. It allows to perform with
sufficient power, all the primary current injections to test the proper
function and wiring of all the elements that compose the protection and
measuring section in a substation.
The regulation system is based on a continuously variable autotrans-
former (Variac) that supplies to a power transformer that delivers the
high current outputs and isolate the main supply from the load. A built-
in ammeter and a timer gives the information about the current value
and the operation time of the relay or breaker under test.
FEATURES
Power outputs
There are four different current outputs:
0 - 10A 0 - 100V
0 - 50A 0 - 20V
0 - 200A 0 - 5V
0 - 400A 0 - 2.5V
Timer
In the control and regulation unit there is a timer installed that can work
with dry signals or with voltage signals the timer can measure in CY-
CLES as well it is an autorange, 5-digit digital timer with the following
measuring ranges:
00.001- 99.999 s
99.999 - 999.99 s
999.99 - 9999.9 s
9999.9 - 99999 s
Ammeter/Voltmeter
Installed in the control and regulation unit it is a digital instrument of
4 digits. The accuracy is 0.5% of the reading 1 digit.
Protections
The equipment is protected by thermal and shortcircuit magnetic relays.
The outputs are also thermal protected to avoid excess in the duty cy-
cle. Once this protection trips the connection of the output is not possi-
ble until the thermal element detects that the temperature drops to an
acceptable and safe level.
STANDARD ACCESORIES
2 test leads of 95 mm
2
section, 2 meters length.
2 timer connection leads, 2 meters length.
2 crocrodile clips.
Spare fuses.
Instruction manual.
1 nylon protection bag.
TECHNICAL SPECIFICATION
EUROSMC, S.A.
Polgono Industrial P-29, Calle Buril, 69. 28400 Collado-Villalba. Madrid (Spain). Tels: 34 - 91 - 849 89 80*. Fax: 34 - 91 - 851 25 53
www.eurosmc.com e-mail: sales@eurosmc.com
VOLTAGE OUTPUTS
Voltage Outputs: VOLTAGE CURRENT
0-220V AC: 220V 4 A
0-220V DC: 220V 4 A
Auxiliary DC Voltage Supply:
0-50V DC: 0-50V 1 A
0-110V DC: 50V-110V 0.5 A
0-220V DC: 110V-220V 0.25 A
DUTY CYCLE
Max. Max. Max. Max. Max. Max. Open
Continuous Current Current Current Current Current Circuit
Current 60 min 15 min 3 min 1 min 1 s Voltage
400 A 600 A 800 A 1,100 A 1,400 A 2.5 kA 3.45V
200 A 350 A 400 A 550 A 700 A 1.5 kA 6.90V
50 A 175 A 100 A 138 A 175 A 325 A 27.5V
10 A 25 A 20 A 27.5 A 35 A 65 A 138V
Cooling Time* 15 min. 20 min. 20 min. 30 min
*Guaranteed values at ambient temperature < 25C
GENERAL
Control: Manual
Voltage supply: 230 V 10%, 50-60 Hz
Operation Temperature: 0 - 55 C
Case: Robust enamalled steel
Weight: 25 kg
Dimensions: Height: 460 mm / 18 Width: 370 mm / 15 Depth: 250 mm / 10
Other similar equipment
LET-400-RD Has exactly the same characteristics as the LET-400-RDC but does not have an
auxiliary DC voltage power supply nor an AC and DC voltage output.
BUILT-IN TIMER
Measuring Ranges: Time: 0.001 a 99999 s. (autorange)
Cycles: 000.1 a 9999.9 Cycles (referenced frequency)
Accuracy: 0.003% of the reading 1 dig.
Time Start: By activation/deactivation of the power output.
Timer Stop: Selectable between activation or deactivation
of the Signal Monitor.
SIGNAL MONITOR
Dry Contact Input: Open circuit voltage: 10.2 V DC
Short-circuit current: 25 mA.
Fuse protected.
Voltage Input: Level Limits: from 5 to 250 V AC/DC
Input Impedance: 19 k
Fuse protected.
LET-400-RDC ingles 16/6/03 16:17 Pgina 2
Power Parameters