General Characteristics
Capacitor Switching Contactors fitted with 2 per phase quick discharge resistors to limit inrush peack currents Early make auxiliary contacts in series with resistors Conform to utilization category AC 6B Contacts design assuring high electrical life Limited losses during on conditions Standard of reference : IEC - 60947 Clip on mounting: - Din rail 35 mm up to CSC 25 - Din rail75 mm from CSC 33 and above Suitable for connection outside the delta configuration
General Characteristics
Digital microprocessor regulator for automatic power Factor correction systems 5 or 7 or 12 step version including programming for Alarm and cooling fan control Accurate readings and reliable power factor correction Even in presence of harmonics content Rms voltage and current measurements Average weekly power factor measurement Adjustable tripping sensivity Adjustable reconnection time No voltage release protection Protection against capacitor overload and panel overheating RS 232 interface (serial port) Easy installation to be combined with external ct Standard of reference: IEC/EN 61010-1
Technical Characteristics
Supply voltage Rated frequency Power consumption Rated current Operation range Power factor setting Temperature range Capacitor overload Reconnection time Tripping sensivity Housing flush mounting Degree of protection Service temperatre Type of terminal Maximum cable section 380 V 415 V other on request 50 / 60 Hz+ -1% self configurable 5,8 VA (ER 5 / ER 7) 4,2 VA ER 12 5 A (1A on request) 0,125 6 A 0,8 inductive - 0,8 capacitive - 40 c / + 100 c (measuring) 0 250% (current) 5-240 s (same step) 5 600 s/step Flush Mounting IP 54 (ER5 ER7) IP 41 (ER 12) - 20 c / + 60 c Plug in 2,5 sq mm PRODUCT RANGE From 10KVAR through 60 KVAR, available in eight ratings, conforming to IEC - 60947 BENEFITS Conforms to utilization category AC 6B Saves cost of expensive replacements High electrical life Reduced watt loss during ON condition, saves energy High Safety No risk of dangerous voltage Switching of Capacitor bank in parallel without de-rating Less maintenance & down time
Description
Front plate 3 digit display Led indicators 7 for main functions Automatic recognition of current flow 4 quadrant operation
100/110
40 H I L
During switching operations capacitors are affected by very high currents. Inrush current can reach values 180 times the rated current of the capacitor. To limit the inrush current and the damages on the capacitors it is advisable to limit the current surge by inserting quick discharge series damping risistors like in our CSC contactors.
Protections
A D 50
High voltage low voltage High current low current Over compensation Under compensation Capacitor overload Over temperature No voltage release
F C B E
C 80 85 93 98
D 74 75 84 84
E 45 45 56 56
F 35 35 40 40
Kvar 33,3 40 60
TYPE
PA96x96
RATED VOLTAGE V
NO Auxiliary
NA Contacts
96
96
6
65 53 31
ORDER CODE
STEPS
Weight
CSC - 10 CSC - 12.5 CSC - 16.7 CSC - 20 CSC - 25 CSC - 33 CSC - 40 CSC - 60
10 12.5 16.7 20 25 33 40 60
1 1 1 1 1 1 1 1
1 1 1 1 1 2 2 2
96
ER 5 ER 7 ER 12
NO 5 7 12
NO 1 1 1
96
Aux. Coil voltages: (Volts) 24 - 48 - 110- 220 - 380 - 400 - 415 - 440 VoltageTolerance20%+10% Ratedinsula ngvoltage690V (*): Average temperature over a 24-hour period, according with IEC-70 and IEC-831 For ambient temperature up to 70 C de-rating the power contactor by a percentage equal to the difference between the operating ambient temperature and 50
PA96x96