The document describes the Self-Contained Control System (SCMS) used with Cameron MH70 hydraulic actuators. The SCMS provides a complete shutdown unit for a gate valve and actuator assembly without an outside power source. It uses fail-safe closing hydraulic circuitry to close the valve under various emergency conditions like low pressure, fire, or emergency shutdown. The SCMS is designed to operate across the full range of MH70 series actuators and provides a single source solution from Cameron.
The document describes the Self-Contained Control System (SCMS) used with Cameron MH70 hydraulic actuators. The SCMS provides a complete shutdown unit for a gate valve and actuator assembly without an outside power source. It uses fail-safe closing hydraulic circuitry to close the valve under various emergency conditions like low pressure, fire, or emergency shutdown. The SCMS is designed to operate across the full range of MH70 series actuators and provides a single source solution from Cameron.
The document describes the Self-Contained Control System (SCMS) used with Cameron MH70 hydraulic actuators. The SCMS provides a complete shutdown unit for a gate valve and actuator assembly without an outside power source. It uses fail-safe closing hydraulic circuitry to close the valve under various emergency conditions like low pressure, fire, or emergency shutdown. The SCMS is designed to operate across the full range of MH70 series actuators and provides a single source solution from Cameron.
The document describes the Self-Contained Control System (SCMS) used with Cameron MH70 hydraulic actuators. The SCMS provides a complete shutdown unit for a gate valve and actuator assembly without an outside power source. It uses fail-safe closing hydraulic circuitry to close the valve under various emergency conditions like low pressure, fire, or emergency shutdown. The SCMS is designed to operate across the full range of MH70 series actuators and provides a single source solution from Cameron.
Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004
SCM Control System.doc Page 1 of 5
SCMS Self-Contained Control System For Use with MH70 Hydraulic Actuators
Description
Self-Contained Control Systems are required when no outside power source is available. The SCMS is used with the MH70 hydraulic actuator to provide a complete shutdown unit implementing a Cameron Gate valve, the Cameron MH70 Bonnet and actuator assembly along with the SCMS, designed as a unit, providing a single source approach. The model of the SCMS System is designed to operate and mount to the complete range of the MH70 Series Actuators.
Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004 SCM Control System.doc Page 2 of 5
Design Features Single Source Approach Cameron offers the valve, bonnet, actuator, and control system as a unit providing the customer with a single source supplier for their Safety System needs.
Failsafe-Closing Design Closed loop hydraulic circuitry for the control system in conjunction with the MH7035 Actuator assures that when a device is triggered within the control panel via low flowline pressure, high flowline pressure, fire, or ESD, the actuator will close the valve, shutting off production.
Thermal Expansion A 5000 PSI Hydraulic Accumulator is installed in the system with a nitrogen pre-charge on the top side of the piston, to accommodate temperature volume changes of the fluid contained in the closed loop circuit.
High/Low Pressure Sensors High and Low pressure sensors are mounted on the flowline to protect the flowline from being over pressured or shut the system in when there is a drop of flowline pressure below the required set point. Various pressure ranges are available for most applications
Fusible Plug A fusible plug is installed in the control system to ensure that if there is a fire at the well, the fusible plug will melt, releasing the hydraulic pressure to the actuator, closing the valve.
Low Pressure Instrument Circuit A regulator is installed to reduce the pressure from the high pressure circuit to a lower pressure. This is what is known as instrument pressure. This instrument pressure feeds your ESD Valve, Fusible Plug, and pressure sensors. This low pressure, allows you to extend into the control system for ESD, Fusible Plug, and Pressure Sensors. This allows you to extend the fusible plug and the high/low pilots away from the actuator if required. This pressure does not exceed 200 PSI. A relief valve is installed downstream of the regulator to assure that the circuit cannot be over pressured.
5000 PSI Rated System The maximum output to the actuator from our standard SCMS is 5000 PSI. A relief valve is installed in the system to assure that the system will not exceed 5000 PSI. Higher pressure systems are available upon request.
Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004 SCM Control System.doc Page 3 of 5
Technical Information
Item Qnty Description Manufacturer Part Number A 1 Check/Stump Strainer BWB Controls 6A-C6L-SS-S B 1 Hydr. Hand Pump Star Hydraulics P2A-LR C 1 Relief Valve Nupro SS-4R3A1-A D 1 Hydr. Regulator Tescom BB-43AL2PV99 E 1 Hydr. Controller BWB Controls HCT-2CM F 1 Accumlator Parker A2N00150-C3K-UT G 1 Fusible Plug Reith 38FP-SS-212 H 1 Reservoir Custom 2 Gallon J 2 Press. Sensor BWB Controls RH-Pilot K 1 Mntg. Block BWB Controls 6" Mntg. Block L 1 ESD Panic Valve BWB Controls N-2 M 1 Pressure Gauge McDaniels 6000 psi K6k-GF N 1 Pressure Gauge McDaniels 200 psi KF-GF Material List D-1 E-1 F-1 G-1 A-1 B-1 L-1 H-1 J-1 J-2 K-1 C-1 M-1 M-1 Field Installation RP040395 Flowline Fusible Plug Actuated Valve High/Low Pilot Assembly Instrument Pressure Hand Pump and Handle Downstream Flowline Actuator Pressure Interface Valve ESD Valve Regulator Hydraulic Reservor Actuator Instrument Manifold Accumulator Gate Valve RP040393
Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004 SCM Control System.doc Page 4 of 5 Low Pilot Block Manifold High Pilot
High/Low Pilot Information BWB Type RH Pressure Sensors
Diaphragm Assembly 0.5 - 3 PSI Low Pressure Assembly 3 - 10 PSI No. 1/2 Piston Assembly 5 - 800 PSI No. 1/2A Piston Assembly 50 - 1200 PSI No. 2/3 Piston Assembly 200 - 2500 PSI No. 4/5 Piston Assembly 900 - 10000 PSI Sensing Piston Range Capability Extended Range w/ 1/2A Piston Assembly Type "RH" High Flow Pressure Shensor Pressure Chart Pneumatic or Hydraulic Service Sensing Assembly Diameter Spring Diaphragm 2-11/16" Plain 0.5 - 3 PSI Low Pressure 1-5/8" Plain 3 - 10 PSI No. 1/2 Piston 1-3/8" Plain 5 - 15 PSI 1-3/8" Red 15 - 50 PSI 1-3/8" White 40 - 170 PSI 1-3/8" Blue 80 - 300 PSI 7/8" White 150 - 400 PSI 7/8" Blue 200 - 800 PSI No. 1/2A Piston 1-3/8" White 50 - 175 PSI 11-16" White 175 - 650 PSI 1-3/8" Blue 150 - 300 PSI 11-16" Blue 300 - 1200 PSI No. 2/3 Piston 7/8" Blue 200 - 800 PSI 1/2" Blue 500 - 2500 PSI No. 4/5Piston 3/8" Blue 900 - 4500 PSI 1/4" Blue 2000 - 10000 PSI Adjustable Range Piston / Diameter / Spring / Adjustable Ring BWB Controls, Inc. Piston Assemblies NO. 1/2 Piston Assembly NO. 1/2A Piston Assembly NO. 2/3 Piston Assembly NO. 4/5 Piston Assembly NO. 1/2 Sleeve 012-90D Oring 012 Back-Up Ring 018-90D ORing 018 Back-Up Ring NO. 2/3 Piston No. 1/2A Piston 015-90D ORing No. 1/2 Piston 006-90D ORing 006 Back-Up Ring 010-90D ORing 010 Back-Up Ring No. 4/5 Piston No. 2/3 Sleeve 026-90D ORing 026-70D ORing No. 1/2A Sleeve 026-70D Oring 018-90D ORing 026-90D ORing No. 4/5 Sleeve Connection 1/4" NPTF 1/2" NPTM *Sensing Pressure Only Panel Mount 1-9/16" Diameter Hole Manifold 6" Mount Block (PSHL) 3" Mount Block (PSH or PSL) Port A PSH-Supply Inlet PSL-Exhaust (30-150 PSI) Orifice .125" Port B PSL-Supply Inlet PSH-Exhaust .125" Port C Supply Pressure Outlet .125" Port D Supply Pressur Inlet (0.5-10000PSI) .187" Installation Adjustment Bolt Spool Valve Adjustment Bolt Lockring Spring Guide Spring Body Port "C" Supply Pressure Outlet Port "A" Supply Pressure Inlet High Pilot Port "B Supply Pressure Inlet Low Pilot Sensing Sleeve Sensing Piston Base 1/2" NPTM 1/4" NPTF Sensing Pressure Inlet
Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004 SCM Control System.doc Page 5 of 5
Options and Accessories
Control System Devices Options Solenoid Valves for remote shutdown Via SCADA Adaptable Remote ESD Stations Fusible Plugs 160F, 212F, 283F, (71C, 100C, 139C) First Out Indication Pressure switches for Remote indication Enclosed Panel Configuration available Panel Mounted Pressure Sensors available Dual output systems available for SCSSV circuits Actuator Mounted or Stand Mounted are available
Control System Options Cameron also has other types of systems available to fit all types of applications. Such As:
Single Well Pneumatic Control Panels Dual Well Pneumatic Control Panels Solar Powered Compressor Pneumatic Panels Solar Powered Hydraulic Panels Custom Systems to fit most types of applications