Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SCMS 7035

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004

SCM Control System.doc Page 1 of 5


SCMS Self-Contained Control System
For Use with MH70 Hydraulic Actuators



Description

Self-Contained Control
Systems are required when
no outside power source is
available. The SCMS is
used with the MH70
hydraulic actuator to provide
a complete shutdown unit
implementing a Cameron
Gate valve, the Cameron
MH70 Bonnet and actuator
assembly along with the
SCMS, designed as a unit,
providing a single source
approach. The model of the
SCMS System is designed
to operate and mount to the
complete range of the MH70
Series Actuators.



Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004
SCM Control System.doc Page 2 of 5

Design Features
Single Source Approach
Cameron offers the valve, bonnet, actuator, and control
system as a unit providing the customer with a single
source supplier for their Safety System needs.

Failsafe-Closing Design
Closed loop hydraulic circuitry for the control system in
conjunction with the MH7035 Actuator assures that
when a device is triggered within the control panel via
low flowline pressure, high flowline pressure, fire, or
ESD, the actuator will close the valve, shutting off
production.

Thermal Expansion
A 5000 PSI Hydraulic Accumulator is installed in the
system with a nitrogen pre-charge on the top side of the
piston, to accommodate temperature volume changes of
the fluid contained in the closed loop circuit.















High/Low Pressure Sensors
High and Low pressure sensors are mounted on the
flowline to protect the flowline from being over
pressured or shut the system in when there is a drop of
flowline pressure below the required set point. Various
pressure ranges are available for most applications

Fusible Plug
A fusible plug is installed in the control system to
ensure that if there is a fire at the well, the fusible plug
will melt, releasing the hydraulic pressure to the
actuator, closing the valve.

Low Pressure Instrument Circuit
A regulator is installed to reduce the pressure from the
high pressure circuit to a lower pressure. This is what is
known as instrument pressure. This instrument pressure
feeds your ESD Valve, Fusible Plug, and pressure
sensors. This low pressure, allows you to extend into
the control system for ESD, Fusible Plug, and Pressure
Sensors. This allows you to extend the fusible plug and
the high/low pilots away from the actuator if required.
This pressure does not exceed 200 PSI. A relief valve is
installed downstream of the regulator to assure that the
circuit cannot be over pressured.

5000 PSI Rated System
The maximum output to the actuator from our standard
SCMS is 5000 PSI. A relief valve is installed in the
system to assure that the system will not exceed 5000
PSI. Higher pressure systems are available upon
request.








Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004
SCM Control System.doc Page 3 of 5

Technical Information

Item Qnty Description Manufacturer Part Number
A 1 Check/Stump Strainer BWB Controls 6A-C6L-SS-S
B 1 Hydr. Hand Pump Star Hydraulics P2A-LR
C 1 Relief Valve Nupro SS-4R3A1-A
D 1 Hydr. Regulator Tescom BB-43AL2PV99
E 1 Hydr. Controller BWB Controls HCT-2CM
F 1 Accumlator Parker A2N00150-C3K-UT
G 1 Fusible Plug Reith 38FP-SS-212
H 1 Reservoir Custom 2 Gallon
J 2 Press. Sensor BWB Controls RH-Pilot
K 1 Mntg. Block BWB Controls 6" Mntg. Block
L 1 ESD Panic Valve BWB Controls N-2
M 1 Pressure Gauge McDaniels 6000 psi K6k-GF
N 1 Pressure Gauge McDaniels 200 psi KF-GF
Material List
D-1
E-1
F-1
G-1
A-1
B-1
L-1
H-1
J-1 J-2
K-1
C-1
M-1
M-1
Field Installation
RP040395
Flowline
Fusible
Plug
Actuated
Valve
High/Low
Pilot Assembly
Instrument Pressure Hand Pump and Handle
Downstream
Flowline
Actuator Pressure
Interface Valve
ESD Valve
Regulator
Hydraulic Reservor
Actuator
Instrument Manifold
Accumulator
Gate Valve
RP040393


Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004
SCM Control System.doc Page 4 of 5
Low Pilot
Block
Manifold
High Pilot

High/Low Pilot Information
BWB Type RH Pressure Sensors














Diaphragm Assembly 0.5 - 3 PSI
Low Pressure Assembly 3 - 10 PSI
No. 1/2 Piston Assembly 5 - 800 PSI
No. 1/2A Piston Assembly 50 - 1200 PSI
No. 2/3 Piston Assembly 200 - 2500 PSI
No. 4/5 Piston Assembly 900 - 10000 PSI
Sensing Piston Range Capability
Extended Range w/ 1/2A Piston Assembly
Type "RH" High Flow Pressure Shensor
Pressure Chart
Pneumatic or Hydraulic Service
Sensing Assembly Diameter Spring
Diaphragm 2-11/16" Plain 0.5 - 3 PSI
Low Pressure 1-5/8" Plain 3 - 10 PSI
No. 1/2 Piston 1-3/8" Plain 5 - 15 PSI
1-3/8" Red 15 - 50 PSI
1-3/8" White 40 - 170 PSI
1-3/8" Blue 80 - 300 PSI
7/8" White 150 - 400 PSI
7/8" Blue 200 - 800 PSI
No. 1/2A Piston 1-3/8" White 50 - 175 PSI
11-16" White 175 - 650 PSI
1-3/8" Blue 150 - 300 PSI
11-16" Blue 300 - 1200 PSI
No. 2/3 Piston 7/8" Blue 200 - 800 PSI
1/2" Blue 500 - 2500 PSI
No. 4/5Piston 3/8" Blue 900 - 4500 PSI
1/4" Blue 2000 - 10000 PSI
Adjustable Range
Piston / Diameter / Spring / Adjustable Ring
BWB Controls, Inc.
Piston Assemblies
NO. 1/2
Piston Assembly
NO. 1/2A
Piston Assembly
NO. 2/3
Piston Assembly
NO. 4/5
Piston Assembly
NO. 1/2 Sleeve
012-90D Oring
012 Back-Up Ring
018-90D ORing
018 Back-Up Ring
NO. 2/3 Piston
No. 1/2A Piston
015-90D ORing
No. 1/2 Piston
006-90D ORing
006 Back-Up Ring
010-90D ORing
010 Back-Up Ring
No. 4/5 Piston
No. 2/3 Sleeve
026-90D ORing
026-70D ORing
No. 1/2A Sleeve
026-70D Oring
018-90D ORing
026-90D ORing
No. 4/5 Sleeve
Connection 1/4" NPTF 1/2" NPTM *Sensing Pressure Only
Panel Mount 1-9/16" Diameter Hole
Manifold 6" Mount Block (PSHL) 3" Mount Block (PSH or PSL)
Port A PSH-Supply Inlet PSL-Exhaust (30-150 PSI) Orifice .125"
Port B PSL-Supply Inlet PSH-Exhaust .125"
Port C Supply Pressure Outlet .125"
Port D Supply Pressur Inlet (0.5-10000PSI) .187"
Installation
Adjustment Bolt
Spool Valve
Adjustment
Bolt Lockring
Spring Guide
Spring
Body
Port "C"
Supply Pressure
Outlet
Port "A"
Supply Pressure Inlet
High Pilot
Port "B
Supply Pressure Inlet
Low Pilot
Sensing Sleeve
Sensing Piston
Base
1/2" NPTM
1/4" NPTF
Sensing
Pressure Inlet


Cameron Willis Actuator Products PDS0005 Cooper Cameron Corporation, 2004
SCM Control System.doc Page 5 of 5

Options and Accessories

Control System Devices Options
Solenoid Valves for remote shutdown Via
SCADA
Adaptable Remote ESD Stations
Fusible Plugs 160F, 212F, 283F, (71C, 100C,
139C)
First Out Indication
Pressure switches for Remote indication
Enclosed Panel Configuration available
Panel Mounted Pressure Sensors available
Dual output systems available for SCSSV
circuits
Actuator Mounted or Stand Mounted are
available













Control System Options
Cameron also has other types of systems available to fit all
types of applications. Such As:

Single Well Pneumatic Control Panels
Dual Well Pneumatic Control Panels
Solar Powered Compressor Pneumatic Panels
Solar Powered Hydraulic Panels
Custom Systems to fit most types of applications

You might also like