Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Uzin NC 110

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Calcium-sulphate based smoothing compound with Level Plus Effect for thicknesses up to 50 mm

Composition: Calcium sulphate, mineral fillers, polyvinyl ace-


tate copolymers, high-performance fluidifers and additives.
3
Extremely good flowability
3
Very smooth surface
3
Rapid drying
3
Up to 10% less adhesive consumption
3
Virtually stress free
3
Can be used over old waterproof adhesive residues
3
EMICODE EC 1 PLUS/Very low emissions
3
RAL UZ 113/ environmentally friendly, due to very low
emissions
Technical Data:
Packaging: paper sack
Pack size: 25 kg
Shelf life: min. 12 months
Required water quantity: 6 litre per 25 kg sack
Colour: light grey/white
Consumption: approx. 1.4 kg /m
2
per mm thickness
Minimum working temperature: 15C/59F at floor level
Ideal working temperature: 15 25C/59 77F
Working time: 20 30 minutes*
Set to foot traffic: after 2 hours*
Ready for covering: after approx. 24 hours*
Fire classification: A1fl acc. to DIN EN 13 501-1
*At 20C/68F and 65% relative humidity with maximum layer thickness of 3 mm.
See also Readiness for laying.
UZIN NC110
L
e
v
e
l P
lu
s
E
ffe
c
t
Description:
Very low emission and high performance gypsum based
smoothing compound for interior use. Particularly suitable
for renovation of old substrates.
Extremely good flow property, producing a uniform and
homogeneous appearance.
Can be pumped applied.
Suitable for:
3
producing level, absorbent surfaces for textile and resilient
floor coverings
3
new calcium sulphate screeds
3
on existing surfaces in need of refurbishment in domes-
tic and commercial locations
3
hot water underfloor heating
3
exposure to castor wheels according to DIN EN 12 529
from 1 mm level thickness
PRODUCT DATA SHEET
Gypsum-based levelling Compound
UZIN KOLINE
Offers highest possible protection against emissions and con-
tributes in creating a healthy living environment. Was awarded
the Blue Angel for low-emission floor covering adhesives and
other adhesives in compliance with RAL-UZ 113.
UZIN | A Brand of Uzin Utz AG
DE | Uzin Utz AG | Dieselstrae 3 | DE-89079 Ulm | Telefon +49(0)731 4097-0 | Telefax +49(0)731 4097-214 | E-Mail info@uzin.com | Internet www.uzin.com
GB | Uzin Ltd. | Unit 2, Mitchell Court | Central Park, Rugby, Warwickshire | CV23 0UY | Phone +44 (0)1788 530 080 | Fax +44 (0)1788 536 508 | E-mail info@uzin.co.uk
| Internet www.uzin.co.uk
UZIN UTZ AG
Dieselstrae 3
D-89079 Ulm
13
01/01/0009.01
EN 13813:2002
Calcium sulphate levelling
compound for substrates
in interior locations
EN 13 813: CAC30F7
Reaction to fire A1fl
Release of
corrosive CA
substances
pH 7
Compressive
strength
C 30
Flexural
strength
F7
Areas of use:
Suitable on new substrates, e. g. on:
3
calcium sulphate screeds, mastic asphalt screeds IC 10
and IC 15 or cement screeds
3
fabricated screeds, e. g. gypsum fibreboards
3
chipboards V 100 or OSB panels, screwed or laid floating
Suitable on old substrates, e. g. on:
3
magnesia and stone wood screeds
3
old mastic asphalt screeds IC 10 and IC 15
3
old calcium sulphate or cement screeds, concrete
3
old, including floating chipboards V 100 or OSB panels
and with old adhesive or levelling compound residues
on their surfaces
3
old substrates, e. g. on dense, adhering, waterproof
adhesive bed
3
existing ceramic and natural stone floorings, terrazzo,
etc.
Product Properties /Benefits:
UZIN NC 110 is virtually stress free when drying. This is
particularly beneficial for unstable substrates and deep fill
projects, resulting in a crack free surface even when thick
applications are left exposed for lengthy periods. Dilapidated
substrates can be salvaged avoiding time consuming and
expensive remedial work.
UZIN NC 110 is quick drying and ready for foot traffic
after 2 hours.
UZIN NC110
Level Plus
Effect
With hardly any usage restriction, UZIN NC 110 is highly
reliable.
Application Example:
Old screeds with unstable adhesive and poorly adhering
levelling compound layers can be renovated with UZIN NC
110 low-stress levelling compound.
Substrate Preparation:
The substrate must be sound, load-bearing, dry, free of
cracks, clean and free of materials (dirt, oil, grease) which
could impair adhesion. Cement and calcium sulphate
screeds must be abraded and vacuumed. Test the substrate
according to applicable standards and report any defi-
ciencies.
Remove any unstable or adhesion-reducing layers, e.g.
release agents, loose adhesives, levelling compounds,
coverings or paint residues, etc., e. g. by brushing off,
abrading, milling or cutting or shot-blasting. Thoroughly
vacuum loose parts and dust. According to type and condi-
tion of the substrate, select a suitable UZIN primer. Allow
the primer to dry completely.
Refer to the Product Data Sheets for other products used.
Application:
1. Put 6 litres of cold, clean water into clean container.
Sprinkle in sack contents (25 kg) into the water whilst
stirring vigorously until a smooth and lump-free consis-
tency is obtained. Use a drill or mixer fitted with a
UZIN Mixing Paddle.
2. Pour out the mix onto the substrate and distribute
evenly with a smoothing trowel or the UZIN Screed
Rake. For thicker coats or when using the screed rake,
the flow and surface can be improved by removing air
using the UZIN Spike Roller. Where possible, apply to
the desired thickness in one coat.
Consumption:
Thickness Consumption 25 kg sack covers
approx.
1 mm 1.4 kg/m
2
18 m
2
3 mm 4.2 kg/m
2
6 m
2
10 mm 14.0 kg/m
2
2 m
2
Spreading UZIN NC 110:
Thickness Ideal quantity
10 15 mm 30% UZIN Finde Sand 0.8
(8 kg sand /25 kg powder)
15 30 mm 50% UZIN Coarse Sand 2.5
(12.5 kg sand /25 kg powder)
30 50 mm 50% screed sand 0 8 mm
(12.5 kg sand/25 kg powder)
According to sand, thickness and moisture content, water is correspondingly reduced.
Ready for Covering:
Thickness Ready for covering:
up to 3 mm 24 hours*
each additional mm further 24 hours*
> 5 mm 0.5 CM %
*At 20C/68F and 65% relative humidity.
As a rule of thumb a 3 mm layer can installed upon after
24 hours*. For each additional 1 mm allow an extra
24 hours*. If the thickness is over 5 mm, use a CM device
to check the residual moisture; the product is ready for
covering if 0.5 CM %.
*At 20C/68F and 65% relative humidity.
Practical Note:
Planned top covering Thickness Ready for
application
Textile coverings 3 mm approx. 1 day*
Resilient coverings,
e. g. PVC, linoleum, rubber
5 mm 2 3 days*
Resilient coverings,
e. g. PVC, linoleum, rubber
10 mm approx. 7 days*
Resilient coverings,
e. g. PVC, linoleum, rubber
20 mm 10 14 days*
Multi-layer wood flooring,
installed with 3 mm 2 3 days*
reaction resin adhesives
*At 20C/68F and 65 % relative humidity.
For effective drying there should be constant air flow and
the temperature of the air and floor should be at least
15C/59F, ideally > 20C/68F.
For thick applications or under poor climate conditions,
a condensation dryer can be used to aid the drying time.
UZIN NC110
Level Plus
Effect
Important Notes:
3
Shelf life minimum 12 months in original packaging when
stored in dry conditions. Carefully and tightly reseal opened
packaging and use the contents as quickly as possible.
3
Optimum conditions are 15 25C/59 77F and relative
humidity below 65%. Low temperatures, high humidity and
greater thickness will delay, whilst high temperatures and low
humidity will accelerate the setting, drying and readiness for
covering. In summer, store in cool conditions and use cold
water.
3
Expansion, movement and wall connection joints must be
extended through the substrate. If necessary, attach UZIN
perimeter insulation strips to rising structures to prevent the
compound from flowing into connection joints. In general,
perimeter insulation strips are necessary for layer thicknesses
over 5 mm.
3
Can be pumped with continuously mixing spiral pumps, e.g.
from manufacturers such as m-tec, P.F.T. and others.
3
Minimum thickness 1 mm for chair castor suitability. Apply
2 3 mm thick to non-absorbent substrates, e. g. old screeds
with a full cover of old, waterproof adhesive residues or on
mastic asphalt screeds.
3
When applying in several coats, allow the compound to dry
completely, prime with UZIN PE 360 and, when this is dry
(approx. 4 6 hours*), apply the next coat.
3
For thickness above 10 mm on surfaces that are moisture
sensitive (calcium sulphate screeds) or weak (old adhesive
residues), use epoxy resin primer, such as UZIN PE 460 gritted.
3
If laying on old mastic asphalt screeds, floating chipboards
V 100 or OSB panels the maximum thickness is 10 mm. Prime
substrate with water-free primer first, e. g. with UZIN PE 414
Turbo (2 coats), UZIN PE 460 or UZIN KR 410, each gritted.
3
The minimum layer thickness under multi-layer wood flooring
is 3 mm. Pay particular attention to adequate drying of the
levelling compound before bonding the wood flooring.
3
Do not use outdoors or in wet areas.
3
When sanding down self-levelling gypsum-based compounds,
a very fine micro-dust is produced. This must be vacuumed
with a high-performance industrial vacuum cleaner so as to
ensure that a good adhesive bond is created between levelling
compound, adhesive and covering.
3
Obtain technical advice before for use under PO and PUR
flooring, cork and wood flooring.
3
Follow the generally acknowledged best practice require-
ments and technology for the installation of floor covering an
wood flooring as well as all respective applicable standards
(e.g. EN, DIN, OE, SIA, etc.). The following standards and bulle-
tins represent supporting information and are recommended
for special attention.
DIN 18 365 Working with floor coverings
DIN 18 356 Working with wood floorings
TKB leaflet Assessment and preparation of surfaces for floor
covering and parquet work
BEB leaflet Assessment and preparation of surfaces
UZIN NC110
Level Plus
Effect
Protection of the Workplace and the Environment:
Gypsum-based levelling compound, non-alkaline and, therefore, hygienic in the work-
place and generally harmless. The use of barrier creams is recommended. Keep out of
the reach of children! When mixing, wear a dust-mask and gloves when indicated.
Thorough ventilation must be ensured during and after the installation and drying time
of the product. Do not eat, drink or smoke during the installation. After contact with
eyes or skin, wash immediately with plenty of water. Do not allow dispersal into drains,
sewers or ground. Rinse tools with water and soap immediately after use. Produces no
physiological or ecological risk when fully cured.
EMICODE EC 1 PLUS very low emission. Within the scope of current knowledge,
gives off no emissions of formaldehyde, hazardous materials or volatile organic
compounds (VOC). Basic prerequisites for best possible indoor air quality following
floor covering work are conformity to standards of the working conditions, as well as
thoroughly dry substrate, primer and smoothing compound.
Hotline for allergy information +49 (0)731 4097-0
Disposal:
Where possible, collect product residues and re-use. Do not allow dispersal into drains,
sewers or ground. Empty paper bags are recyclable. Collect waste material, mix with
water and allow to harden, then dispose as Construction Waste.
The above information is based on our experience and careful investigations. The variety of associated materials and different construction and working conditions cannot be indi-
vidually checked or influenced by us. The quality of your work depends, therefore, on your own professional judgement and product usage. If in doubt, conduct a small test or obtain
technical advice. Observe the installation recommendations of the covering manufacturer. The publication of this Product Data Sheet invalidates all previous Product Information.
The respective updated version of this datasheet can be found on our Homepage under www.uzin.com. 05.13 | 05.13 | 0.000 | LD| leR