Cod Lab Report
Cod Lab Report
Experiment Background
The chemical oxygen demand (COD) determines the amount of oxygen required
for chemical oxidation of organic matter using a strong chemical oxidant, such as,
potassium dichromate under reflux conditions. This test is widely used to determine:
a)
b)
c)
d)
The limitation of the test lies in its inability to differentiate between the biologically
oxidizable and biologically inert material and to find out the system rate constant of
aerobic biological stabilization.
Most of the organic matters are-destroyed when boiled with a mixture of
potassium dichromate and sulphuric acid producing carbon dioxide and water. A sample
is refluxed with a known amount of potassium dichromate in sulphuric acid medium and
the excess of dichromate is titrated against ferrous ammonium sulphate. The amount of
dichromate consumed is proportional to the oxygen required to oxidize the oxidizable
organic matter.
Concept of Literature
The Chemical Oxygen Demand (COD) test measures the oxygen equivalent
consumed by organic matter in a sample during strong chemical oxidation. The strong
chemical oxidation conditions are provided by the reagents used in the analysis.
Potassium dichromate is used as the oxygen source with concentrated sulfuric acid
added to yield a strong acid medium. Several reagents are added during the set up of
the analysis to drive the oxidation reaction to completion and also to remove any
possible interferences. Specifically, these reagents are mercuric sulfate, silver sulfate
and sulfamic acid. Mercuric sulfate is added to remove complex chloride ions present in
the sample. Without the mercuric sulfate the chloride ions would form chlorine
compounds in the strong acid media used in the procedure. These chlorine compounds
would oxidize the organic matter in the sample, resulting in a COD value lower than the
actual value. Silver sulfate is added as a catalyst for the oxidation of short, straight
chain organics and alcohols. Again, without the silver sulfate the COD of the sample
would be lower than the actual value. Sulfamic acid is added to remove interferences
caused by nitrite ions. Without sulfamic acid the COD of the sample would measure
higher than the actual value.
Even with the use of these additional reagents the oxidation of the organic matter
is not always 100% complete. Volatile organics, ammonia and aromatic hydrocarbon
are not oxidized to any great degree during the procedure.
The advantages of the COD test as compared to the BOD test are:
COD results are available much sooner.
The COD test requires fewer manipulations of the sample.
The COD test oxidizes a wider range of chemical compounds.
It can be standardized more easily.
The major disadvantage of the COD test is that the results are not directly
applicable to the 5-day BOD results without correlation studies over a long period of
time. The samples used for the COD analysis may be grab or composite. Preservation
of the sample can be accomplished by adding sulfuric acid to depress the pH to 2 and
the holding time with preservation is 7 days.
Objectives
To measure the chemical oxygen demand of the given wastewater sample.
Procedure
Result
DILLUTION
FACTOR
X1
X2
X3
SAMPLE
AVERAGE
0
2
20
50
0
557
249
25
0
557
249
25
0
557
249
25
0
557
249
25
Blank
Sample 1
Sample 2
Sample 3
Calculation
FINAL
READING
(mg/L)
0
557
249
25
Discussion
The COD value indicated the amount of oxygen which is needed for the oxidation of all
organic substance in water in mg/l. The COD is closely related to the laboratory
standard method named dichromate method. With this method the chemical oxygen
demand in determine during chromic acid digestion is wastewater.
After the experiment, the average of sample for 2x is 557 mg/l, sample for 20x is 249
mg/l, and 249 mg/l for sample 3.from our result we can know that the highest value is at
the sample for 2x. The sample give difference result because the sample used the
different volume of palm oil sample. Thus we would get the difference volume of sample
shown by the result.
During the experiment, there will be some error happen. When carried out the
experiment and when we tittering there could be some free air bubble inside the
pipette. Sometimes, we also did not make sure that the pipette is in the clean condition.
We should be ensure that there is no bubble inside. For that, we can get accurate
reading. The purpose of clean pipette is to avoid the chemical in pipette from mixing
with our chemical.
Furthermore, during our experiment, parallax error also can happen. We must ensure
that we always read the pipette with the right way that s read the bottom of the
meniscus. If we avoid to occur parallax error, we will getting more accurate result.
Conclusion
In environmental chemistry, the COD test is commonly used to indirectly measure the
amount of organic compounds I water. Most application of COD determine the amount
of organic pollutants found in surface water such as pond, lakes and rivers that making
COD a useful measure of water quality. It is ex pressed in miligrams per liter (mg/l)
which indicates the mass of oxygen consumed per liter of solution. Older references
may express the units as parts per million (ppm).