Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

KOR-1B4H Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 33

S/M No.

: R1B4H0A002

Service Manual
Microwave Oven

Model : KOR-1B4H

Caution:
In this Manual, some parts can be changed for improving,
their performance without notice in the parts list. So, if you
need the latest parts information, please refer to PPL(Parts
Price List) in Service Information Center (http://svc.dwe.co.kr).

Jul. 2008

PRECAUTIONS TO BE OBSERVED BEFORE AND


DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs if necessary: (1) Interlock operation, (2) Proper door closing, (3)
Seal and sealing surfaces (arcing, wear, and other damage), (4) Damage to or loosening of hinges and
latches (5) Evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave generating
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described
in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal performance standard should be
performed on each oven prior to release to the owner.

TABLE OF CONTENTS
SAFETY AND PRECAUTIONS........................................................................................................................................3
FOR SAFE OPERATION ...........................................................................................................................................3
FOR SAFE SERVICE PROCEDURES .....................................................................................................................3
SPECIFICATIONS ............................................................................................................................................................4
EXTERNAL VIEW .............................................................................................................................................................5
OUTER DIMENSION .................................................................................................................................................5
FEATURE DIAGRAM.................................................................................................................................................6
CONTROL PANEL .....................................................................................................................................................7
INSTALLATION ................................................................................................................................................................8
OPERATIONS AND FUNCTIONS ...................................................................................................................................9
DISASSEMBLY AND ASSMBLY...................................................................................................................................10
INTERLOCK MECHANISM AND ADJUSTMENT.........................................................................................................17
TROUBLESHOOTING GUIDE .......................................................................................................................................18
MESUREMENT AND TEST............................................................................................................................................22
MEASUREMENT OF THE MICROWAVE POWER OUTPUT................................................................................22
MICROWAVE RADIATION TEST ...........................................................................................................................23
COMPONENT TEST PROCEDURE .......................................................................................................................24
WIRING DIAGRAM.........................................................................................................................................................25
PRINTED CIRCUIT BOARD...........................................................................................................................................27
CIRCUIT CHECK PROCEDURE.............................................................................................................................27
PCB CIRCUIT DIAGRAM ........................................................................................................................................30
P.C.B. LOCATION NO. ............................................................................................................................................31
EXPLODED VIEW AND PARTS LIST ...........................................................................................................................32
DOOR ASSEMBLY ..................................................................................................................................................32
CONTROL PANEL ASSEMBLY ..............................................................................................................................32
TOTAL ASSEMBLY .................................................................................................................................................32

SAFETY AND PRECAUTIONS


CAUTION : This Device is to be Serviced Only by Properly Qualified Service Personnel. Consult the Service
Manual for Proper Service Procedures to Assure Continued Safety Operation and for Precautions
to be Taken to Avoid Possible Exposure to Excessive Microwave Energy.
1. FOR SAFE OPERATION
Damage that allows the microwave energy (that cooks or heats the food) to escape will result in poor cooking and
may cause serious bodily injury to the operator.
IF ANY OF THE FOLLOWING CONDITIONS EXIST, OPERATOR MUST NOT USE THE APPLIANCE.
(Only a trained service personnel should make repairs.)
1) A broken door hinge.
2) A broken door viewing screen.
3) A broken front panel, oven cavity.
4) A loosened door lock.
5) A broken door lock.
The door gasket plate and oven cavity surface should be kept clean.
No grease, soil or spatter should be allowed to build up on these surfaces or inside the oven.
DO NOT ATTEMPT TO OPERATE THIS APPLIANCE WITH THE DOOR OPEN. The microwave oven has
concealed switches to make sure the power is turned off when the door is opened. Do not attempt to defeat them.
DO NOT ATTEMPT TO SERVICE THIS APPLIANCE UNTIL YOU HAVE READ THIS SERVICE MANUAL.
2. FOR SAFE SERVICE PROCEDURES
1) If the oven is operative prior to servicing, a microwave emission check should be performed prior to servicing
the oven.
2) If any certified oven unit is found to have excessive emission level 5mw/cm2, the serevice person should:
(a) inform the manufacturer, importer or assembler,
(b) repair the unit at no cost to the owner,
(c) attempt to ascertain the cause of the excessive leakage,
(d) tell the owner of the unit not to use the unit until the oven has been brought into compliance.
3) If the oven operates with the door open, the service person should tell the user not to operate the oven and
contact the manufacturer and CDRH immediately.

CAUTION
MICROWAVE RADIATION
PERSONNEL SHOULD NOT BE EXPOSED TO THE MICROWAVE ENERGY WHICH MAY RADIATE
FROM THE MAGNETRON OR OTHER MICROWAVE GENERATING DEVICE IF IT IS IMPROPERLY
USED OR CONNECTED. ALL INPUT AND OUTPUT MICROWAVE CONNECTIONS. WAVEGUIDES
FLANGES AND GASKETS MUST BE SECURED. NEVER OPERATE THE DEVICE WITHOUT A
MICROWAVE ENERGY ABSORBING LOAD ATTACHED. NEVER LOOK INTO AN OPEN WAVEGUIDE
OR ANTENNA WHILE THE DEVICE IS ENERGIZED.

SPECIFICATIONS
MODEL

KOR-1B4H0A

POWER SUPPLY

120V~60HZ, SINGLE PHASE WITH EARTHING


1500 W

1400 W

MICROWAVE ENERGY OUTPUT

1100 W

1000W

MICROWAVE FREQUENCY

2450MHz

OUTSIDE DIMENSIONS (W X H X D)

560X344X471mm (22.0X13.5X18.5 in.)

CAVITY DIMENSIONS (W X H X D)

369X246X394mm (14.5X9.7X15.5 in.)

NET WEIGHT

APPROX. 16.7kg

TIMER

99min. 99sec.

FUNCTION SELECTIONS

MICROWAVE

POWER SELECTIONS

10 LEVELS

CAVITY VOLUME

1.3 Cu. Ft

POWER
CONSUMPTION

MICROWAVE

KOR-1B4H9A04

GRILL
COMBINATION

* Specifications are subject to change without notice.

EXTERNAL VIEW
1. OUTER DIMENSION

471

344

560

2. FEATURE DIAGRAM

2 1

3 9

5
8
0

1. DOOR SEAL
Door seal maintains the microwave within the oven cavity and prevents microwave leakage.
2. DOOR HOOK
When door is closed, it will automatically lock shut. If door is opened while oven is operating, magnetron tube will
immediately stop operating.
3. DOOR SCREEN
Allows viewing of food. Microwave cannot pass through perforations in screen.
4. SPATTER SHIELD
Protects the microwave outlet from splashes of cooking foods.
5. OVEN LAMP
Automatically turns on during oven operating.
6. SAFETY INTERLOCK SYSTEM
7. CONTROL PANEL
8. GLASS COOKING TRAY
Made of special heat resisant glass. The tray must always be in proper position before operating. Do not cook food
directly on the tray.
9. OVEN FRONT PLATE
10. ROLLER GUIDE
Supports the glass cooking tray.

3. CONTROL PANEL

2
M/W

DEF TIMER LOCK

lb

3
POPCORN

MORE
BEVERAGE

6
7

9
q

FROZEN
PIZZA

MEAT

DINNER
PLATE
LESS

FRESH
FROZEN
VEGETABLE VEGETABLE
POULTRY

POWER

FISH

DEFROST

KITCHEN
TIMER

CLOCK

START/
SPEEDY COOK

STOP/CLEAR

8
1
0
w

1. Time Set Pad - Used to set the cooking time and the present time.
2. Display - Cooking time, power level, indicators and present time are displayed.
3. One touch cooking - Used to cook or reheat specific quantities of food.
4. More - Used to add time to cooking.
5. Less - Used to remove time from cooking.
6. Auto Defrost - Used to defrost foods.(for weight)
7. Power - Used to set power level.
8. Defrost - Used to defrost foods.(for time)
9. Kitchen Timer - Used as a minute timer, delay cooking, hold setting after cooking.
10. Clock - Used to set clock.
11. Stop/Clear - Used to stop the oven operation or to delete the cooking data.
12. Start/Easy Cook - Used to start the oven and also used to set a reheat time.

INSTALLATION
1. Steady, flat location.
This microwave oven should be set on a steady, flat surface.

2. Leave space behind and side.


All air vents should be kept a clearance. If all vents are covered during operation, the oven may be overheated
and, eventually, cause oven failure.

3. Away from radio, and TV sets


Poor television reception and radio interference may result if the oven is located close to a TV, radio, antenna, or
feeder and so on. Position the oven as far from them as possible.

4. Away from heating appliances and water taps


Keep the oven away from hot air, steam or splash when choosing a place to position it, or the insulation might be
adversely affected and breakdowns occur.

5. Power supply
Check your local power source.
This microwave oven requires a current of approximately 20 amperes, 120Volts, 60Hz grounded outlet.
1. A short power-supply cord is provided to reduce the risks resulting from becoming entangled in or trippping over a
longer cord.
2. Longer cord sets or extension cords are available and may be used if care is exercised in their use.
3. If a long cord or extension cord is used:
1) The marked electrical rating of the cord set or extension cord should be at least as great as the electrical rating
of the appliance.
2) The extension cord must be a grounding type 3-wire cord.
3) The longer cord should be arranged so that it will not drape over the counter top or tabletop where it can be
pulled on by children or tripped over unintentionally.

6. Examine the oven after unpacking for any damage such as:
A misaligned door, broken door or a dent in cavity.
If any of the above are visible, DO NOT INSTALL, and notify dealer immediately.

OPERATIONS AND FUNCTIONS


1. Connect the mains lead to an electrical outlet.
2. After placing the food in a suitable container, open the oven door and put it on the glass tray. The glass tray must
always be in place during cooking.
3. Close the door securely.
4. The oven door can be opened at any time during operation by touching the door release button on the control
panel.
The oven will automatically shut off. To restart the oven, close the door and then touch the START.
5. Each time a pad is touched, a BEEP will sound to acknowledge the touch.
6. The oven automatically cook on full power unless set to a lower power level.
7. The display will show : 0 when the oven is plugged in.
8. Time clock returns to the present time when the cooking time ends.
9. When the STOP/CLEAR pad is touched during the oven operation, the oven stops cooking and all information
retained.
To erase all information (except the present time), touch the STOP/CLEAR pad once more. If the oven door is
opened during the oven operation, all information is retained.
10. If the START pad is touched and the oven does not operate, check the area between the door and door is closed
securely. The oven will not start cooking until the door is completely closed or the program has been reset.
Make sure the oven is properly installed and plugged into the electrical outlet.
Wattage output chart
The power level is set by touching the POWER pad. The chart shows the display, the power level and the percentage
of power.
Touch POWER Pad.

Power Level(Display)

Approximate Percentage of Power

Once

P-HI

100%

Twice

P-90

90%

3 times

P-80

80%

4 times

P-70

70%

5 times

P-60

60%

6 times

P-50

50%

7 times

P-40

40%

8 times

P-30

30%

9 times

P-20

20%

10 times

P-10

10%

11 times

P-00

0%

DISASSEMBLY AND ASSEMBLY


- Cautions to be observed when troubleshooting.
Unlike many other appliances, the microwave oven is high-voltage, high-current equipment. It is completely safe
during normal operation. However, carelessness in servicing the oven can result in an electric shock or possible
danger from a short circuit. You are asked to observe the following precautions carefully.
1. Always remove the power plug from the outlet before servicing.
2. Use an insulated screwdriver and wear rubber gloves when servicing the high voltage side.
3. Discharge the high voltage capacitor before touching any oven components or wiring.
(1) Check the grounding.
Do not operate on a two-wire extension cord.
The microwave oven is designed to be used while grounded.
It is imperative, therefore, to make sure it is grounded
properly before beginning repair work.
(2) Warning about the electric charge in the high voltage capacitor.
For about 30 seconds after the operation has stopped, electric
charge remains in the high voltage capacitor.
When replacing or checking parts, short between oven chassis
and the negative high terminal of the high voltage capacitor by
using a properly insulated screwdriver to discharge.
4. When the 20A fuse is blown due to the operation of the monitor
switch; replace primary interlock switch, secondary interlock switch
and interlock monitor switch.
5. After repair or replacement of parts, make sure that the screws are
properly tightened, and all electrical connections are tightened.
6. Do not operate without cabinet.

CAUTION : Service personnel should remove their watches whenever working close to or replacing the magnetron.

WARNING : When servicing the appliance, take care when touching or replacing high potential parts because of
electrical shock or exposing microwave. These parts are as follows - HV Transformer, Magnetron,
HV Capacitor.

10

1. To remove cabinet
1) Remove four screws on cabinet back.
2) Pull the cabinet backward.

2. To remove door assembly


1) Remove two screws which secure the stopper hinge top.
2) Remove the door assembly from top plate of cavity.
3) Reverse the above for reassembly.

NOTE : After replacing the door assembly, perform a check of correct alignment with the hinge and cavity front plate.

11

3. To remove door parts.


A09

A10
A08
A13
A06

A04

A11

A03

A12
A07

A02

A01

A05

DOOR ASSEMBLY PART CODE: 3511716000

REF NO.
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13

PART CODE
3512603540
3511605510
3511605400
3511605700
3511605600
3512204750
7001503511
3517009000
3515204900
3516602100
3513101200
3515101800
3512302310

PART NAME
HANDLE DOOR
DECORATOR DOOR *U
DECORATOR DOOR *T
DECORATOR DOOR *L
DECORATOR DOOR *R
FRAME DOOR
SCREW MACHINE
BARRIER-SCREEN *O
STOPPER HINGE *T AS
DOOR-PLATE
HOOK
SPRING HOOK
GASKET DOOR

DESCRIPTION
ABS MP-0160
STS304 T0.5
STS304 T0.5
STS304 T0.5
STS304 T0.5
ABS
PAN 5X35 MFZN
TEMP GLASS T3.2
KOC-1B4K0S
SBHG-1A T0.7
POM
PW1
PP

(1) Remove the gasket door(A13) from door plate.


(2) Remove two screws(A07) from door plate.
(3) Remove the door handle (A01) from door plate.
(4) Remove the four door decorators (A02~A05) from door frame.
(5) Remove the door frame (A06) from door plate.
(6) Remove the stopper hinge top(A09) from door plate.
(7) Remove the spring(A12) and the hook(A11).
(8) Remove the barrier screen outer(A08) from door frame.
(9) Reverse the above steps for reassembly.

12

QTY
1
1
1
1
1
1
2
1
1
1
1
1
1

REMARK

4. Method to reduce the gap between the door seal and the oven front surface.
(1) To reduce gap located on part A.

Loosen two screws on stopper hinge top, and then push the
door to contact the door seal to oven front surface.
Tighten two screws.

M/W

DEF

TIMER

LOCK

FROZEN
PIZZA

POPCORN

MORE

(2) To reduce gap located on part B.

FRESH

BEVERAGE

VEGETABLE

MEAT

POULTRY

Tighten two screws.

NOTE : A small gap may be acceptable if the microwave leakage does not exceed 4mW/cm2.

13

FISH

KITCHEN
TIMER

STOP/CLEAR

the door to contact the door seal to oven front surface.

FROZEN
VEGETABLE

DEFROST

POWER

Loosen two screws on stopper hinge under, and then push

lb

DINNER
PLATE
LESS

9
CLOCK

START/
SPEEDY COOK

5. To remove control panel parts.

B05

B03

B04

B02

B01

CONTROL-PANEL ASSEMBLY PART CODE


: PKCPSWKT00

REF NO.

PART CODE

B01

3518523400

SWITCH MEMBRANE

PART NAME

KOR-1B4H0A

DESCRIPTION

QTY
1

B02

3511607600

DECORATOR C-PANEL

STS430 HL T0.5

B03

3516727000

CONTROL PANEL

ABS AF-348, VT-0826

B04

PKMPMSKT00

B05

7122401211

PCB AS

KOR-1B4H0A

SCREW TAPPING

T2S TRS 4X12 MFZN

REMARK

(1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
(2) Remove four screws which secure the PCB assembly to control panel.
(3) Disconnect membrane tail from the connector of the PCB assembly.
(4) Detach membrane from the control panel.
(5) Pull out the decorator c-panel from the control panel.
(6) Reverse the above steps for reassembly.

14

6. To remove high voltage capacitor.


1) Remove a screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.

High voltage circuit wiring

7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.

NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 4mW/cm2 for a fully assembled oven with door normally closed.

15

8. To remove wind guide assembly.


1) Remove a screw which secure the wind guide assembly.
2) Draw forward the wind guide assembly.
3) Pull the fan from the motor shaft.
4) Remove two screws which secure the motor shaded pole.
5) Remove the motor shaded pole.
6) Reverse the above steps for reasembly.

9. To remove H.V.transformer.
1) Remove four screws holding the H.V.transformer.
2) Remove the H.V.transformer.
3) Reverse the above steps for reassembly.

16

INTERLOCK MECHANISM AND ADJUSTMENT


The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when
the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.

(1) Primary interlock switch


When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate.
When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch
bring it under ON condition.
(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock
monitor switch to bring it under OFF condition. The lock lever presses the button of the secondary interlock switch to
bring it under ON condition.
ADJUSTMENT :
Interlock monitor switch
When the door is closed, the interlock monitor switch should be changed (OFF condition) before other switches are closed.
When the door is opened, the interlock monitor switch should be changed (ON condition) after other switches are opened.
(3) Adjustment steps
a) Loosen two mounting screws.
b) Adjust interlock switch assembly position.
Actuation distance of primary and secondary interlock switch shall be adjusted almost 1.4 mm.
c) Make sure that lock lever moves smoothly after adjustment is completed.
d) Tighten completely two mounting screws.
NOTE :
Microwave emission test should be performed after adjusting interlock mechanism.
If the microwave emission exceed 4mW/cm2, readjust interlock mechanism.

17

TROUBLE SHOOTING GUIDE


Following the procedure below to check if the oven is defective or not.
1) Check grounding before trouble checking.
2) Be careful of the high voltage circuit.
3) Discharge the high voltage capacitor.
4) When checking the continuity of the switches, fuse or high voltage tranformer, disconnect one load wire from these
parts and check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to
your meter.

NOTE : When electric parts are checked, be sure the power cord is not inserted the wall outlet.
Check wire harness, wiring and connection of the terminals and power cord before check the parts listed below.

(TROUBLE 1) Oven does not operate at all : any inputs can not be accepted.

CONDITION

CHECK

RESULT

Check continuity of interlock


monitor switch with door closed

Continuity

Fuse blows.

CAUSE
Malfunction of
interlock
monitor switch

REMEDY
Replace
NOTE 1

No Continuity
Replace fuse

Check continuity of of primary


interlock switch contact with door
partially open until interlock
monitor switch contact close

Check continuity of primary


winding of low voltage
transformer

Continuity
No Continuity

0 or infinite
Approx.
150~310
(normal)

Normal

Disconnect one side of the lead


wire connected form high
voltage transformer to the high
voltage capacitor and operate
the unit

Fuse again
blows

18

Shorted
contacts of
primary
interlock switch.

Defective low
voltage
transformer

Defective high
voltage capacitor

Defective high
voltage
transformer

Replace
NOTE 1

Replace

Replace

Replace

CONDITION
Outlet has
proper
voltage Fuse
does not
blow.

CHECK

RESULT

CAUSE

REMEDY

No
Continuity

Defective
magnetron

Replace

Check continuity of magnetron

Check continuity of
power supply cord

No
Continuity

Open power
supply cord

Replace

Normal

Defective touch
control circuit

Replace

Malfunction of
secondary
interlock switch

Replace

Display do not shown


countdown

NOTE 1
All these switches must be replaced at the same time, please refer to Interlock Mechanism And Adjustment.

(TROUBLE 2) Display shows all figures selected, but oven does not start cooking, even though desired program and
time are set and start pad is tapped.

CONDITION

CHECK

RESULT

CAUSE

REMEDY

Turn table
motor and
oven lamp
do not turn
on

Check continuity of primary


interlock switch

No
Continuity

Malfunction of
primary interlock
switch

Adjust or
replace

Check continuity of secondary


interlock switch

No
Continuity

Malfunction of
secondary
interlock
switch

Adjust or
replace

Check D.C. voltage being


supplied to RELAY (RY2) coil

0V

Defective touch
control circuit

Replace

Approx.
15 VDC

Faulty contacts of
RELAY (RY2) or
open relay coil

19

Replace

(TROUBLE 3) No microwave oscillation even though fan motor rotates.

CONDITION
No
microwave
oscillation

CHECK

RESULT

CAUSE

REMEDY

Check continuity of high


voltage capacitor terminals
with wires removed

Continuity

Defective high
voltage
transformer

Replace

Check continuity of high voltage


rectifier in forward and backward
direction with DC megger

Continuity in
backward
direction

Defective high
voltage rectifier

Replace

Connect megger leads to


magnetron terminal and
magnetron body

Continuity

Defective
magnetron

Replace

Defective high
voltage
transformer

Replace

0 or

Check resistance of primary and


secondary coil of high voltage
transformer

No
Continuity

Check continuity of magnetron


with wires removed

No
Continuity

Check continuity of filament


terminal of high voltage
transformer

Defective
magnetron

Defective high
voltage
transformer

0V
Check D.C. voltage being
supplied to RELAY (RY1) coil

Defective touch
control circuit

Approx
15 VDC

20

Faulty
contacts or
RELAY (RY1)
or open
relay coil

Replace

Replace

Replace

Replace

(TROUBLE 4) The following visual conditions inditions indicate a probable defective touch control circuit or
membrane switch assembly
1. Incomplete segments,
1) Segments missing.
2) Partical segments missing.
3) Digit flickering other than normal display slight flickering.
4) " :0" does not display when power is on.
2. A distinct change in the display is not on when they should be.

M/W

DEF TIMER LOCK

lb

3. One or more digits in the display are not on when they should be.
4. Display indicates a number different from one touched.
5. Specific numbers (for example 2 or 3) will not display when the panel is touched.
6. Display does not count down or up with time cooking or clock operation.
7. Oven is programmable and cooks normally but no display shows.
8. Display obviously jumps in time while counting down.
9. Display counts down noticeable too fast while cooking.
10. Display does not show the time of day when the Clear pad is touched.
11. Oven lamp and turntable motor do not stop although cooking is finished. Check if the RELAY 2 contacts close if they
are close, replace touch control circuit.

CONDITION

CHECK

Display does
not show
programming
at all, even if
keyboard is
touched.

Check rach pad for


continuity of the membrane
keyboard for the following
keyboard check procedure

RESULT
Normal

Abnormal

CAUSE

REMEDY

Malfunction
of touch
control circuit
of control box
sub-assembly

Replace
control box
sub-assembly

Malfunction
of the membrane
keyboard

Replace the
membrane
keyboard

NOTE
Before following the particular steps listed above in the troubleshooting guide for the membrane keyboard's,
failure, please check for the continuity of each wire-harness between the membrane keyboard and P.C.B.
assembly.

21

MEASUREMENT AND TEST


1. MEASUREMENT OF THE MICROWAVE POWER OUTPUT
Microwave output power can be checked by indirectly mmeasuring the temperature rise of a certain amount of water
exposed to the microwave as directed below.
PROCEDURE
1. Microwave power output measurement is made with the microwave oven supplied at rated voltage and operated at
its maximum microwave power setting with a load of 100 5cc of potable water.
2. The water is contained in a cylindrical borosilicate glass vessel having a maximum material thickness of 3 mm and
an outside diameter of approximately 190 mm.
3. The oven and the empty vessel are at ambient temperature prior to the start of the test. The initial temperature of
the water is 10 2C (50 3.6F). If is measured immediately before the water is added to the vessel. After
addition of the water to the vessel, the load is immediately placed on the center of the shelf, which is in the lowest
normal position.
4. Microwave power is switched on.
5. Heating time should be exactly A seconds.
(Refer to table as following)
Heating time is measured while the microwave
generator is operating at full power. The filament heatup time for magnetron is not included.
6. The initial and final temperature of water is selected so
that the maximum difference between the ambient and
final water temperature is 5K.
7. The microwave power output P in watts is calculated
from the following formula:
P = 4187 X T/t
T is difference between initial and final temperature.
t is the heating time.
The power measured be B (Refer to SPECIFICATIONS) W 10.0 %.

CAUTION
1. Water load should be measured exactly to 1 liter.
2. Input power voltage should be exactly specified voltage (Refer to SPECIFICATIONS).
3. Ambient temperature should be 20 2C (68 3.6F)

Heating time for power output:


A (second)

70

64

60

56

52

49

47

44

42

40

38

B (W)

600

650

700

750

800

850

900

950

1000

1050

1100

22

2. MICROWAVE RADIATION TEST


CAUTION
1. Make sure to check the microwave leakage before and after repair of adjustment.
2. Always start measuring of an unknown field to assure safety for operating personnel from microwave energy.
3. Do not place your hands into any suspected microwave radiation field unless the safe density level is known.
4. Care should be taken not to place the eyes in direct line with the source of microwave energy.
5. Slowly approach the unit under test until the radiometer reads an appreciable microwave leakage from the
unit under the test.

PROCEDURE
1. Prepare Microwave Energy Survey Meter, 600cc glass beaker,
and glass thermometer 100C (212F).
M/W

DEF

TIMER

LOCK

FROZEN
PIZZA

POPCORN

MORE

2. Pour 275cc 15cc of tap water initially at 20 5C (68 9F) in


the 600 cc glass beaker with an inside diameter of approx.
85 mm(3.5 in.).

lb

DINNER
PLATE
LESS

FRESH

BEVERAGE

VEGETABLE

MEAT

POULTRY

1
4

2
5

KITCHEN
TIMER

STOP/CLEAR

FROZEN
VEGETABLE

FISH

DEFROST

POWER

3
6
9
CLOCK

START/
SPEEDY COOK

3. Place it at the center of the tray and set it in a cavity.


4. Close the door and operate the oven.
5. Measure the leakage by using Microwave Energy Survey Meter
with dual ranges, set to 2450MHz.
1) Measured radiation leakage must not exceed the value
prescribed below. Leakage for a fully assembled oven with
door normally closed must be less than 4mW/cm2.
2) When measuring the leakage, always use the 5 cm (2 in.)
space cone with probe. Hold the probe perpendicular to the
cabinet and door. Place the space cone of the probe on the
door, cabinet, door seem, door viewing screen, the exhaust air vents and the suction air vents.
3) Measuring should be in a counter-clockwise direction at a rate of 1 in./sec. If the leakage of the cabinet door
seem is unknown, move the probe more slowly.
4) When measuring near a corner of the door, keep the probe perpendicular to the areas making sure the probe
end at the base of the cone does not get closer than 2 in. from any metal. If it does not, erroneous reading may
result.

23

3. COMPONENT TEST PROCEDURE


High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.
It is neither necessary nor advisable to attempt measurement of the high voltage.
Before touching any oven components or wiring, always unplug the oven from its power source and discharge the
capacitor.
1. High voltage transformer
1) Remove connections from the transformer terminals and check continuity.
2) Normal readings should be as follows :
Secondary winding ... Approx. 110 10% (100 10% KOR-1B4H9A04)
Filament winding ... Approx. 0
Primary winding ... Approx. 1
2. High voltage capacitor
1) Check continuity of capacitor with meter on the highest OHM scale.
2) A normal capacitor will show continuity for a short time, and then indicate 10M once the capacitor charged.
3) A shorted capacitor will show continuous continuity.
4) An open capacitor will show constant 10M.
5) Resistance between each terminal and chassis should be infinite.
3. High voltage diode
1) Isolate the diode from the circuit by disconnecting the leads.
2) With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals.
Reverse the meter leads and again observe the resistance reading. Meter with 6V, 9V or higher voltage batteries
should be used to check the front-back resistance of the diode, otherwise an infinite resistance may be read in
both directions. A normal diode's resistance will be infinite in one direction and several hundred k in the other
direction.
4. Magnetron
For complete magnetron diagnosis, refer to "Measurement of the Microwave Power Output." Continuity checks can
only indicate and open filament or a shorted magnetron. To diagnose for an open filament or a shorted magnetron,
1) Isolate magnetron from the circuit by disconnecting the leads.
2) A continuity check across magnetron filament terminals should indicate 0.1 or less.
3) A continuity check between each filament terminal and magnetron case should read open.
5. Fuse
If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and
monitor switch before replacing the blown fuse. In case the fuse is blown by an improper switch operation, replace
the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally.
6. Interlock switches
(1) You can test continuity of safety interlock and monitor switch by using ohmmeter.
(2) The switch peration is checked by zero/unlimited.
The meter should indicate zero resistance.
(3) The sequence of check is interlock monitor switch, primary and secondary interlock switches check.

24

WIRING DIAGRAM
KOR-1B4H0A

25

KOR-1B4H9A04

26

PRINTED CIRCUIT BOARD


1. CIRCUIT CHECK PROCEDURE
1. Low voltage transformer check
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 120V / Frequency: 60Hz
Terminal Voltage

LOAD

NO LOAD

4-7

AC 12.6 V

AC 14.7 V

NOTE
1. Refer to Ciruit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source
voltage.
3. The allowable tolerance of the secondary voltage is within 5% of nominal voltage.

2. Voltage Check
- Key check point
NO

CHECK POINT

IC1 PIN 2, 21, 30, 34

IC1 PIN 35

REMARK
-5VDC

T : 16.67ms(60Hz)
3

IC1 PIN 31 OR 32

T : 250 ns(4MHz)

- Check method
NO

MEASURE POINT

WAVE FORM

REMEDY

REMARK

MP1

DC -5V0.25V

Replace VL1, EC1

NO LOAD

MP2

DC -12V2.0V

Replace EC2, D12,13,14

NO LOAD

NOTE
Each measure point must be measured with GND points.

27

MP1

MP2

Mesure point

28

3. When there is no microwave oscillation


1) When touching the START pad, oven lamp does not turn on.
Fan motor do not rotate, but cook indicator in display comes on.
Cause : RELAY 2 does not operate. refer to Circuit Diagram (point 3)
- Check method
POINT

RELAY 2 ON

-5VDC

GND

RELAY 2 OFF

GND

-12VDC

STATE

2) When touching the START pad, oven lamp turns on.


Fan motor and turntable rotate and cook indicator in display comes on.
Cause : RELAY 1 does not operate. refer to Circuit Diagram (point 2)
- Check method
POINT

RELAY 1 ON

-5VDC

GND

RELAY 1 OFF

GND

-12VDC

STATE

4. When the door is opened during operation the count down timer does not stop.
refer to Circuit Diagram (point 1)
- Check method
POINT

1) DOOR OPEN

OPEN

-5VDC

2) DOOR CLOSED

CLOSE

GND

STATE

CHECK NO
1

HETHOD

REMEDY

Check the stage(ON, OFF) of the secondary interlock


switch by resistance measurement.

Replace door open monitor switch.

5. When the digital clock does not operate properly.


refer to Circuit Diagram (point 5)
POINT
A

WAVE FORM

T: 16.67 ms(60Hz)

If clock does not keep exact time, you must check resistor R15,16, zener diode ZD1.

29

2. P.C.B. CIRCUIT DIAGRAM

30

3. P.C.B. LOCATION NO.


NO

NAME

SYMBOL

SPECIFICATION

PART CODE

QTY

3515600100

BUZZER

BZ1

BM-20K

C ARRAY

CA1

7P(6) 102 M 50V

CN6XB-102M

CAPACITOR ELEC

EC1

50V RS 1F

CEXE1H109V

CPAPCITOR ELEC

EC2

25V RSS 1000F

CEXF1E102V

CONNECTOR WAFER

CN1

YW396-02AV

3519150520

CONNECTOR WAFER

CN3

YW396-05AV

3519150510

CONNECTOR WAFER

CN2

FCZ 254-11

441M367160

DIODE RECTIFY

D1~6, 9~12,15

1N4148

DZN4148---

11

DIODE RECTIFY

D13, 14

1N4004A

DZN4004A--

10

DIODE ZENER

ZD1

UZ-5.1BSB

DZUZ5R1BSB

11

DIODE ZENER

ZD2

UZ-3.9BSB

DZUZ3R9BSB

12

LED DISPLAY

DP1

DDG-631H

DDDG631H01

13

PCB MAIN

M158

81.5X139.9

3514315410

14

R ARRAY

RA1

7P(6) 1/8 100K J

RA-87X104J

15

RESISTOR

R1~R7

1/6W 220 5%

RD-AZ221J-

16

RESISTOR

R8, 10, 12, 14, 22

1/6W 1K 5%

RD-AZ102J-

17

RESISTOR

R11, 20, 21

1/6W 100K 5%

RD-AZ104J-

18

RESISTOR

R13

1/6W 200 5%

RD-AZ201J-

19

RESISTOR

R15~16

1/6W 10K 5%

RD-AZ103J-

20

RESISTOR

R17

1/6W 510 5%

RD-AZ511J-

21

RESISTOR

R18

1/6W 1M 5%

RD-AZ105J-

22

RESISTOR

R19

1/4W 51 5%

RD-4Z510J-

23

REGULATOR

VL1

MC7905C

1MC7905C--

24

TRANSISTOR

Q1~5, 9~11

KRA-106M

TZRA106M--

25

TRANSISTOR

Q6

KTA-1266Y

TZTA1266Y-

26

TRANS POWER

LVT1

DMR-631P

5EPU035302

27

WIRE COPPER

J1~3,5~8,10~12,17~21

1/0.52 TIN COATING

85801052GY

15

28

WIRE COPPER

SJ3, 5

1/0.52 TIN COATING

85801052GY

29

IC MICOM

IC1

TMP47C440BN

13GS1B4H00

30

RESONATOR CERA

CR1

KBR-4.0MSTF

5PKBR40MKS

31

SW RELAY

RY1

G5G-1A DC 12V

5SC0101121

32

SW RELAY

RY2

CS11-12SH 1C 1P

5SC0101128

33

CAPACITOR CERA

C6

102 50V Z AXIAL

CCZB1H102K

34

CAPACITOR CERA

C1, C3~C5, C7

104 50V Z AXIAL

CCZF1H104Z

31

EXPLODED VIEW AND PARTS LIST


1. DOOR ASSEMBLY
Refer to Disassembly and assembly

2. CONTROL PANEL ASSEMBLY


Refer to Disassembly and assembly

3. TOTAL ASSEMBLY

F01

F02

F03

F04

F06

F07

F08

F48

F45

F44
F43
F42

F10

F41

F11
F12

F40

F13
F05

F14
F09
F15

A00

F16
F17

B00

F18
F19

F20

F21

F39

F38

F37

F36

F35

F34

F33 F32

F31

F30

32

F29 F28 F27

F26

F25

F24

F23

F22

REF NO

PART CODE

A00

3511716000

B00

PKCPSWKT00

F01

PART NAME

DESCRIPTION

Q'TY

DOOR AS

KOR-1B4H0A

CONTROL PANEL AS

KOR-1B4H0A

3510806800

CABINET

STS430 T0.5 HL (KOR-1B4H0A)

3510805100

CABINET

KOC-1B2K0S (KOR-1B4H9A04)

F02

3516004100

SPECIAL SCREW

T1 TRS LR4 POLE 4X10 MFZN

F03

3516114400

CAVITY AS

KOR-1B4H0A

3516114410

CAVITY AS

KOR-1B4H9A04

F04

7122401211

SCREW TAPPING

T2S TRS 4*12 MFZN

F05

7122401211

SCREW TAPPING

T2S TRS 4*12 MFZN

F06

7122401011

SCREW TAPPING

T2S TRS 4*10 MFZN

F07

35113UHWT5

CORD POWER AS

3X14 AWG 90X90 120-RTML (KOR-1B4H0A)

35113TENM5

CORD POWER AS

3X16 AWG 70X70 100-RTML (KOR-1B4H9A04)

F08

7122401211

SCREW TAPPING

T2S TRS 4*12 MFZN

F09

5F1C020315

FUSE

ONLY KOR-1B4H9A02

F10

7121403011

SCREW TAPPING

T2S PAN 4X30 MFZN

F11

3963822720

MOTOR SHADED POLE

120V 60HZ MW15XA-K03

F12

3512515300

GUIDE WIND

PP

F13

3511800100

FAN

PP GF 20

F14

3518003500

MAGNETRON

RM259(JF) (KOR-1B4H0A)

3518002900

MAGNETRON

2M218(JF)P (KOR-1B4H9A04)

F15

3516003800

SPECIAL SCREW

T2 FLANGE 5X8 MFZN

F16

7272400811

SCREW TAPTITE

TT3 TRS 4X8 MFZN

F17

3513003200

HOLDER HV CAPACITOR

SECC T0.6

F18

3518302300

CAPACITOR HV

2100VAC 1.10F #187 (KOR-1B4H0A)

3518302200

CAPACITOR HV

2100VAC 0.98F (KOR-1B4H9A04)

3518400110

DIODE HV

HVR-1X-70B 12KV #187 (KOR-1B4H0A)

3518400400

DIODE HV

HVR-1X-3AB (KOR-1B4H9A04)

3518118600

TRANS HV

DW-R11A0-1BT (KOR-1B4H0A)

3518118610

TRANS HV

DW-R10A0-1BT (KOR-1B4H9A04)

F21

3516003700

SPECIAL SCREW

T2 FLANGE 5X8 MFZN

F22

3510313500

BASE

SBHG T0.8

F23

7112401011

SCREW TAPPING

T1 TRS 4X10 MFZN

F24

3512101400

FOOT

DASF-310

F25

7272400811

SCREW TAPTITE

TT3 TRS4X8 MFZN

F26

3515202800

STOPPER HINGE *U

KOR-121M0A

F27

3512719000

HARNESS MAIN

KOR-1B4H0A N/F

3512719010

HARNESS MAIN

KOR-1B4H9A04

F19

F20

33

1
4
1

REF NO

PART CODE

PART NAME

DESCRIPTION

F28

3513702100

LEVER SW MICRO

POM

F29

4415A17352

SW MICRO

VP-533A-OF SPNO #187 200G

F30

4415A66600

SW MICRO

VP-532A-OF/SPNO #187 200G

F31

4415A17352

SW MICRO

VP-533A-OF SPNO #187 200G

F32

4415A66910

SW MICRO

VP-531A-OF/SZ,-V16-FA-61

F33

3513700800

LEVER LOCK

POM

F34

3513816000

LOCK

PP

F35

3513601500

LAMP

BL 120V 25W T25 C5A H187

F36

7121400611

SCREW TAPPING

T2S PAN 4X6 MFZN

F37

3966820200

MOTOR SYNCRO

120V 2W GM-16-12F17

F38

3518905600

THERMOSTAT

OFF:80 ON:50 H #187 NR

F39

3513003410

HOLDER THERMOSTAT

PP(BK)

F40

7272400811

SCREW TAPTITE

TT3 TRS 4X8 MFZN

F41

3511408300

COVER WAVE GUIDE

MICA T0.35

F42

3517400620

COUPLER

XAREC

F43

3514700710

ROLLER

TEFLON

F44

3512517200

GUIDE ROLLER

PP

F45

3517207610

TRAY

DIA:340 1300G

F46

3518902900

THERMOSTAT

OFF:144C #187V (Only KOR-1B4H9A04)

F47

7121300611

SCREW TAPPING

T2S PAN 3X6 (Only KOR-1B4H9A04)

F48

3518606840

NOISE-FILTER

DWLF-M29(Only KOR-1B4H0A)