SM 592.2 Caja de Control Electromagnetica
SM 592.2 Caja de Control Electromagnetica
SM 592.2 Caja de Control Electromagnetica
DESCRIPTION
This series of electronic systems is suitable to control
atmospheric gas burners for non-permanent operation with
or without fan in the combustion circuit.
All control units are provided with non-volatile lockout, i.e.
restart from the safety shutdown condition can only be
accomplished by manually resetting the system.
The control units of this series are suitable for:
- combi boilers
- heating boilers
- hot air generators
- radiant tube heaters
- water heaters.
Their technical and manufacturing characteristics and the
variety of models make them suitable also for the
automation of ovens, cookers, stoves and, more generally,
for gas firing appliances equipped with atmospheric burner.
FEATURES
Table 1 shows the main features of this series.
Other important features are mentioned below:
EC type examination certificate (EC Reg. no. 51BT3691)
in accordance with the European Gas Appliance
Directive 90/396 and the following amendment 93/68;
in compliance with EN298:2003 (European standard for
automatic gas burner control and flame detection
systems);
flame detection exploiting the flame rectification effect
(ionization);
two independent safety contacts in series on the gas
valve output;
electrical service life at max declared loading > 250.000
operations;
inbuilt manual reset; some models can be provided with
remote reset;
incorporated highly efficient and completely solid-state
design ignition device;
auxiliary contact for low-power ignition or main valve
control for intermittent pilot systems (this is not a SELV
contact and is therefore not suitable to control circuits
type SELV Safety Extra Low Voltage, e.g. 24V );
different connection and fixing possibilities.
15756_r02
1/6
*
*
*
TECHNICAL DATA
Power supply:
230V 50/60Hz
on request:
110/120V 50/60Hz
Operating temperature range:
-20C +60C
Humidity:
95% max at 40C
Protection degree:
socket NG
IP 40 (after installation)
socket P/R
IP 00
Times:
waiting/pre-purge time (TW):
1,5..40 s
TW for type SM152N
3..40 s
safety time at start-up (TS):
3..60 s
response time in case of flame failure
<1s
The times appearing on the product label correspond to
guaranteed values. Actual times may differ from declares
ones, as waiting and pre-purge time may be longer and
safety time shorter than their nominal values.
Power consumption at start-up:
atmospheric burner
10VA
atmospheric fan-assisted burner 12VA
Power consumption during operation:
atmospheric burner
7VA
atmospheric fan-assisted burner 9VA
Max contact rating:
Imax
- Thermostat:
4A
cos 0.4
- EV1:
0.5A
cos 0.4
- EV2:
0.5A
cos 0.4
- EVG:
0.5A
cos 0.4
- Fan:
1A
cos 0.4
- Lockout signal:
0.5A
cos = 1
- Auxiliary contact:
0.5A
cos 0.4
- External ignition device:
1.5A
cos 0.2
Max cable length for
external components:
1m
Internal fuse rating:
5A
slow-blow
External fuse rating:
3.15A fast-blow
Flame monitoring:
The flame detection device exploits the rectification property
of the flame (ionization); the device is not provided with any
protection impedance and is therefore not safe against the
risk of electric shock.
(B)
(B)
(B)
(B)
*
*
*
*
*
*
*
*
*
*
*
*
Socket MG
*
*
*
*
*
*
*
*
*
Socket NG
AMCLXN
AMCLXN
AMCLXN
FMCLXN
FMCLXN
AMCLXN
AMCLXN
AMCLXN
AMCLXN
Socket R
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
Socket P
*
*
*
*
CONNECTION
Classification according to
EN298 (2)
(B)
(B)
*
*
*
*
Remote
Single electrode
(B)
*
2/6
RESET
Inbuilt
*
*
*
*
*
*
*
OPTIONS
Atmospheric with135
fan
CM191N
SM191N
SM192N
CM381N
CM391N
SM152N
SM592N
MM191N
MM192N
Double flame
BURNER
Single flame
TABLE 1
*
*
*
*
*
*
*
*
*
(1): The auxiliary contact is not type SELV (Safety Extra Low Voltage) and is
therefore not suitable to control SELV circuits.
(2): Flame failure during TS causes spark restoration.
(3): Label showing the marking EN298:2003 compliant and part reference
provided with suffix N.
CONSTRUCTION
The plastic casing protects the control unit from any
damage resulting from impacts, tampering, dust and contact
with the external environment.
A particular construction technique, consisting of four PCBs
assembled together to form a "box" structure, has enabled
to considerably reduce the dimensions of the device.
A varistor protects the control unit from any voltage
transients which may arise in the mains supply.
An inbuilt fuse protects the internal relays of the unit in case
of short circuit on the control outputs (valves, fan and
lockout signal). As this fuse is not accessible, the unit will
have to be protected by an external fast-blow fuse suitable
to the loads connected and never exceeding 3,15A.
15756_r02
OVERALL DIMENSIONS
The EUROBOX series burner control units can be provided
with a different casing according to the characteristics and
fixing systems required.
Casings are available with or without reset push-button and
can be equipped with lateral fixing brackets or not. Please
note that the units equipped with lateral fixing brackets can
be fitted to sockets type "P" or "R" only, as these are
provided with suitable fixing hooks. The numeric suffix in the
part reference indicates the type of casing:
1 with reset push-button;
with fixing brackets
2 with reset push-button;
without fixing brackets
3 without reset push-button;
with fixing brackets
4 without reset push-button;
without fixing brackets
The possibility of using casings without reset push-button is
restricted to the control units prearranged for remote reset.
Fig.1 shows the overall dimensions of the units.
Fig.1
ACCESSORIES
The control units are usually supplied with inbuilt reset
push-button; versions with remote reset supplied with a
suitable light reset push-button are also available (see
Fig.2).
The casings of the control units are prearranged for the use
of strain relieves/cable glands to be mounted on their sides;
also these accessories can be supplied upon request (see
Fig.3).
RESET PUSH-BUTTON
Socket R Fig. 4
DRILLING PLANE
Reset 1
CODE 81020980
3 Neutral
Lockout signal 2
Fig.2
Fig.3
Socket NG Fig. 5
CONNECTION
For this series of burner control units, various
interconnection solutions are possible. In fact, different
types of connecting sockets can be used (see Fig.4 and
Fig.5): types NG (code 18210094) and MG (code
18210113) are equipped with screw terminal board,
whereas types P (code 18210096) and R are provided with
a number of fast-on holders.
Socket type MG differs from type NG for the availability of
an auxiliary terminal requested for the control unit type
INSTALLATION DIRECTIONS
A regulation shutdown should occur every 24 hours to
enable the unit to check its own efficiency (systems for
non-permanent operation).
Ignition systems are safety devices; the manufacturer's
responsibility and guarantee are invalidated in case of
Customer's tampering with the product.
Connect and disconnect the control unit only after
switching off the power supply.
The unit can be mounted in any position.
Avoid exposure to dripping water.
15756_r02
3/6
ELECTRICAL INSTALLATION
Respect the applicable national and European
standards regarding electrical safety (e.g. EN 603351/EN 50165).
Connect live and neutral correctly. The non-observance
of live-neutral polarity may cause a dangerous
situation, as internal and external protection and safety
devices may become ineffective in case the connection
cables of the thermostats and the valves should lose
their insulation. Besides, the non-observance of liveneutral polarity causes lockout at the end of the safety
time at start-up.
Before starting the system check the cables carefully. A
wrong wiring can damage the unit and compromise the
safety of the appliance.
Make sure that the earth terminal of the control system,
the metal frame of the burner and the earth of the mains
supply are well connected.
Avoid placing the detection cable close to power or
ignition cables.
Use heat resistant detection cables and electrodes, and
make sure that they are well insulated to earth and
protected from possible moisture or water in general.
Keep the ignition cable as short and straight as possible
and place it far from other conductors to reduce the
emission of electromagnetic interference (max length
<2m and insulation voltage >25kV).
In case of a live-neutral network with unearthed neutral or
a live-live network (with unearthed star centre), the control
unit can operate as well thanks to an inbuilt resistor;
however, in these cases we recommend using our step-up
transformer type AR1.
In case of bad insulation between live and earth, the
voltage on the ionization probe can be reduced until it
causes the lockout of the control unit.
CHECKING AT START-UP
Check the control system before the first start-up, after any
overhaul and after a long period of non-operation. Before
any ignition attempt make sure that the combustion
chamber is free from gas, then check the following:
if the start-up attempt occurs without gas supply, the
control system should go to lockout at the end of the
safety time;
when stopping the gas flow while the control system is
running, the power supply to the gas valve(s) should be
interrupted within 1s, and the control system should
proceed to lockout after a recycling attempt;
operating times and sequence should correspond to
those declared for the type of control unit you are using;
the level of the flame signal should be high enough (see
Fig.6 for the measuring method to adopt);
the ignition probe should be adjusted in the most stable
way for a spark gap between 2-4 mm;
the intervention of limiters or protection devices should
cause a safety shutdown according to the type of
application.
DETECTION
ELECTRODE
IGNITION
ELECTRODE
Fig.6
OPERATION
At every start-up the control system performs a selfchecking of its own efficiency. During the waiting or prepurge time (TW) the internal circuit tests the correct
operation of the flame signal amplifier. Extraneous light or a
4/6
15756_r02
DETECTION
IGNITION
IGNITION
DETECTION
CONNECTION DIAGRAMS
IGNITION
IGNITION
DETECTION
TYPE CM391N
DETECTION
TYPE CM191N
IGNITION
DETECTION
DETECTION
IGNITION
TYPE SM191N
TYPE MM192N
DETECTION
IGNITION
DETECTION
TYPE MM191N
TYPE CM381N
THERMOSTAT
FAN
AIR PRESSURE
SWITCH
TYPE SM592N
FUSE
BURNER
LOCKOUT
SIGNAL
FIRST
GAS VALVE
SECOND
GAS VALV
AUXILIARY
CONTACT
MAIN
SWITCH
EXTERNAL
IGNITION
TRANSFORMER
5/6
OPERATING DIAGRAMS
TYPE SM191N
TYPE SM592N
TYPE SM152N
THERMOSTAT
FAN
AIR PRESSURE
SWITCH
IGNITION
DEVICE
FLAME
SIGNAL
LOCKOUT
SIGNAL
FIRST
GAS VALVE
SECOND
GAS VALVE
AUXILIARY
CONTACT
EXTERNAL IGNITION
TRANSFORMER
ATTENTION -> Company Brahma S.p.A. takes no responsibility for any damage resulting from Customer's tampering with the device.
BRAHMA S.p.A.
Via del Pontiere, 31
37045 Legnago (VR) ITALY
Tel. +39 0442 635211 Fax +39 0442 25683
http://www.brahma.it
E-mail: brahma@brahma.it
6/6
15756_r02