TI EZP8 1x181x362x36 2011oct
TI EZP8 1x181x362x36 2011oct
TI EZP8 1x181x362x36 2011oct
Technical information
Edition: Oct. 2011
EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240
Subject to change
Applications :
Features:
Product number
Reference
EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240
4008321 367471
4008321 367396
4008321 367457
4008321 367488
4008321 367402
4008321 367464
149mm
202mm
EZP8 1x18/220-240
EZP8 1x36/220-240
Lamp wiring:
Page 1 of 2
EZP8 2x36/220-240
Master lamp
EZTRONIC EZP8
ECG for T8/
26mm fluorescent lamps
Technical information
Edition: Oct. 2011
EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240
Subject to change
Technical data:
Reference:
EZP8 1x18/220-240
EZP8 1x36/220-240
EZP8 2x36/220-240
Lamps:
HF Lamp wattage [W]
System wattage [W]
Line current [A]
L18W
16
20
0.080.09
Ip = 23 A; TH = 100 s
L36W
32
36
0.16
Ip = 23 A; TH = 100 s
2 x L36W
2 x 32
72
0.32
Ip = 22 A; TH = 240 s
34 / 54
34 / 54
15 / 24
56 / 89
56 / 89
25 / 40
Inrush current:
0.51.0
t<0.3 sec.
220 -240V; 50/60Hz
198-264V
> 20 kHz
264V permanent
0.95
-10C...+50C
Max. + 75C
430V
149 x 42 x 30 mm
202 x 42 x 30 mm
139 mm
192 mm
45 Push-in (3+3)
45 Push-in (3+4)
85g
135g
Acc. to IEC 61347-2-3
Acc. to CISPR 15:2005 Edition 7 + A1:2006 including 30-300MHz CDN mode / EN55015
Acc. to IEC61000-3-2
Acc. to IEC61547
50pcs
Approval marks:
Remark: 1) Auto restart feature is on master lamp only. Please see below for more details.
Auto-restart Feature:
With the mains supply connected, the ECG can be auto-reset by simply rotating the MASTER Lamp after relamping. The MASTER Lamp must
be the last lamp to be inserted in order to avoid the mis-triggering of shutdown protection circuit.
Group-relamping is strongly recommended if bad lamp is detected in that fixture, to avoid confusion created by the mixture of new and used lamps
if only partial of lamps are replaced.
Relamping Procedures:
For Single Lamp ECG: Change the defective lamp and ECG will resume the operation immediately.
For Multi Lamp ECG: Replace all of these lamps and ensure that the MASTER Lamp is the last lamp inserted. Rotate the MASTER Lamp to
reset the ECG if necessary.
Page 2 of 2