Provodni Izolatori
Provodni Izolatori
Provodni Izolatori
Sales Aid
April, 2000
Power Transformer
Replacement
Parts
C ACPA
IES
A PAB
B IILLI TIIT
ES
TAP CHANGERS
CONTROLS
BUSHINGS
COOLING UNITS
GAUGES
SUDDEN PRESSURE RELAYS
MECHANICAL RELIEF DEVICES
BUSHING POTENTIAL DEVICES (PBA2)
DEHYDRATING BREATHERS
INERTAIRE
The ABB Components Division, located in Alamo, TN, owns and maintains over 10
million documents and design data on transformers manufactured by:
General Electric (Pittsfield - 40 MVA and larger)
ABB (Muncie and St. Louis)
Central Moloney (St. Louis - 5 MVA and larger)
This detailed and valuable information allows ABB to provide parts that meet or
exceed the original material specifications.
ABB PowerTransmission
TA P
ANN
GRE
TA PCCH
HA
GE
S RS
Tap Changers
CCOO NNTTRORO
LS L S
Panels
Sudden Pressure
Relay Panel
SPR, Fans
Seal-In panels for Sudden Pressure
Relay devices, and Cooling Fans
are carried in stock.
Components
Replacement electrical components are
available for existing control cabinets,
such as relays, circuit breakers and contactors.
ABB PowerTransmission
B UBSU H
S HIIN
N GG
SS
Refurbished/Replacement Bushings
Available for those manufactured by ABB, Westinghouse, General
Type O Plus C
Replacement Bushings
Incorporates the leading condenser design with optimum shell designs.
Flange and cable adapters are available to facilitate replacement.
Refurbished Bushings
Same warranty as new bushings is provided.
Obsolete components are either replaced with those which conform to
original specification or are upgraded to incorporate the latest
technology.
Included is ABBs state-of-the-art fused-ink, capacitive-graded
condenser core with guaranteed lowest power factor and partial
discharge in the industry.
Type O Plus C
Bushings are designed for use in transformers and oil-filled circuit
breakers. Designs exist for oil-to-air, vertical and horizontal
applications. Offered in 400 A to 5000 A current ratings. Available for
15kV through 800kV voltage ratings. Meets or exceeds the
IEEE/ANSI, and CSA standards.
ABB PowerTransmission
BBU
SHH
US
I NIGN
SGS
Type T Bushings
High-current condenser bushings designed for use in
transformers and other oil-filled apparatus for both vertical
and horizontal mounting. Offered in 400A to 21,500 A
Type T
Type A Bushings
Stud-type designs used for applications with oil-filled
transformers and generators for either vertical or horizontal
mounting. Offered in 600 A to 23,000 A current ratings.
Available from 1.2 kV to 34.5 kV voltage ratings. Requires
little maintenance other than periodic cleaning due to the
Type A
All bushing products are
manufactured to the
international standards
ISO 9001.
Type LCRJ
ABB PowerTransmission
C OCO
LLIIN
OO
N GG
Coolers:
Oil Coolers are designed and manufactured by ABB
for the transformer industry and can easily replace
existing models.
Replacement fans, motors, and valves are also
available for existing coolers.
Pump Valve
Rebuild Kit
Radiators:
Replacement Radiators can be manufactured to meet
original requirements. Bolt-on fan assemblies to
replace existing fans and motors are available.
Kits are available to rebuild the older model
Westinghouse radiator valves.
Pumps:
Replacement pumps are available.
Kits are available to rebuild the older model
Westinghouse pump valves.
Fan Assembly
for Radiator
G AU
GGEE SS
G AU
Oil Thermometers
Oil Thermometers are used to indicate the top liquid
temperature of the transformer. Internal switches can
be used to control fans and/or initiate an alarm.
Replacement kits are carried in stock.
Winding Thermometers
Winding Thermometers are used to provide a means
of reading an equivalent of the winding hot spot
temperature. Replacement kits are carried in stock.
Oil Level
Magnetic liquid level gauges are used to indicate the
level of the insulating fluid. A magnetic float arm
positively displaces the magnetic shaft to indicate the
oil level on the gauge face.
Oil Flow
Winding Thermometer
Gauge
ABB PowerTransmission
D EDVE VI C
ESS
ICE
Sudden Pressure Relay
This device is designed to respond to the sudden
increase in gas pressure in a power transformer
which would be caused by an internal arc.
Nuisance trips due to pressure changes caused by
the environment are not detected.
PBA2
Mechanical Relief
Device
Breathers
Dehydrating breathers are used to prevent the
normal moisture in the air from coming in contact
with the oil in electrical equipment as the internal
pressure varies. The use of this device would
reduce the degredation of the oil and help maintain
its insulation capability. Dehydrating breathers
come in seven sizes for application on equipment
with oil volumes from 235 to 9,600 gallons. They
are filled with Silicagel which can absorb 20% of
its own weight in moisture.
PBA2
ABB PowerTransmission
Dehydrating
Breather
D E VD IEC
V IE
CS
ES
Inertaire
This system includes all of the pressure
regulating controls needed to maintain a
positive pressure nitrogen atmosphere in the
gas space of the transformer. This nitrogen
blanket protects the transformers oil from
deterioration caused by exposure to
moisture or oxygen. When the gas space
pressure falls below the low pressure limit,
the Inertaire system automatically feeds
fresh nitrogen into the transformer gas
space until the pressure is restored to a
value above the low pressure limit. When
the pressure exceeds the high pressure
limit, the system vents the excess pressure
to the atmosphere through a relief valve.
RNB Inertaire System