Lab Report (Portal Frame)
Lab Report (Portal Frame)
1.0
OBJECTIVE
1.) To establish the relationship between applied load and horizontal reaction at the
pinned support.
2.) To observe the effect of the load position on the horizontal reaction.
2.0
INTRODUCTION
32 | P a g e
3.0
APPARATUS
5N Load
4.0
PROCEDURE
1. The load cell is connected to the digital indicator.
33 | P a g e
5.0
Results:
34 | P a g e
W
a
L1
B
L3
Width of member,
b = 25 mm
Thickness of member,
h = 9 mm
L1 = 600 mm
L3 = 600 mm
a = 500 mm
Load, W (N)
5
10
15
20
25
Calculations:
35 | P a g e
The equations for the horizontal reaction at the pinned support A of a portal frame are
given below:
HA
LPH
AHH
Where;
LPH WaL 1 (a L3 ) / 2 EI
2
[ ] [
a L1 ( aL3 )
600 ( 5 00600 )
5 00 X
3
2 EI
2 X 200 X 10 X 1 519
H A =W 2
=W
=W (0.0417 )=0.0417 W
L1 ( 2 L1+3 L3 )
6002 ( 2 X 600+ 3 X 600 )
3
3 EI
3 X 200 X 10 X 1 519
By using the data from Table above, the graph of Load versus Horizontal
Reaction at A supports are plotted which shown as below.
36 | P a g e
The best straight line is drawn through the points plotted. From the graph plotted,
the slope of the line, m is determined. (m represents the slope of experimental)
error =
0.04170.04
x 100=4.08
0.0417
37 | P a g e
6.0
DISCUSSION
The result obtained from the experiment 1 contains error by comparing it to
theory. There is a variation between experimental and theoretical data, 4.08%
error. The error occurred are due to several factors such as: Inaccuracy reading from the digital indicator due to:
Human error:
7.0
CONCLUSION
From the result obtained, we conclude that the experiments consist of
small variation errors which caused by few factors. By this, there are few
suggestions in order to determine an accuracy of portal frame experiment. Such
as:
o Care handling should be taken during application of the weights
o Readings are to be determined accurately
From the experiment, it is obviously shown that the more loading apply to
the portal frame, the bigger the displacement at the roller. And the more loading
apply, the deflected shape and bending moments of the portal frame will be
increasing.
38 | P a g e
8.0
APPENDIX
39 | P a g e
40 | P a g e