Reusing Treated Effluent in Concrete Technology: Ooi Soon Lee, Mohd Razman Salim, Mohammad Ismail & Md. Imtiaj Ali
Reusing Treated Effluent in Concrete Technology: Ooi Soon Lee, Mohd Razman Salim, Mohammad Ismail & Md. Imtiaj Ali
Reusing Treated Effluent in Concrete Technology: Ooi Soon Lee, Mohd Razman Salim, Mohammad Ismail & Md. Imtiaj Ali
1.0
INTRODUCTION
Sewage water originates mainly from domestic sources and comprises 99.9% water
and 0.1% organic and inorganic solids in settleable, suspended, and soluble forms.
Untreated sewage is a hazard to both public health and to the environment. Therefore, sewage water is treated in a sewage treatment plant before discharging into an
inland waterway. Industrial and trade wastes in Malaysia are treated separately by
on-site industrial waste treatment plants [1]. By the end of 1997, Indah Water
Konsortium (IWK) was given the responsibility of maintaining a total of 4,539 sewage treatment plants with a population of 7,416,486 [2]. Table 1 shows the sewerage
systems managed by IWK from 1994-1997. Currently, the treated effluent from sewage treatment plants is flowed directly into waterways. With proper water quality
control, this treated effluent can also be considered as a potential water resource for
specific applications.
The application of reusing treated effluent from sewage treatment plant in agricultural sector and industry has been carried out successfully in developed countries
[35]. Therefore, the focus of this study is to consider the applicability of reusing the
treated effluent in concrete technology since some non-potable water are found to
be suitable as the concrete mixing water [6]. This paper presents the results of a
laboratory study using treated effluent as mixing water for concrete.
1,2,3&4
Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul
Takzim, Malaysia.
Untitled-30
02/16/2007, 17:20
Untitled-30
803
2,266
1,232
Perak
Selangor
Kuala Lumpur
02/16/2007, 17:20
100
40
Pahang
Terengganu
180
--
16
40
38
42
29
--
Network
Pump
Stations
4,539
175
176
390
440
435
14
177
1,250
660
394
413
15
STPs
736,797
18,409
59,760
150,211
33,055
29,993
3,120
36,670
94,289
184,810
4,886
110,592
11,002
Septic
Tanks
+Population using septic tanks is assumed to be five times the number of septic tanks.
7,052
344
Johor
Total
234
Melaka
466
1,372
Pulau Pinang
N. Sembilan
170
Kedah
23
Perlis
Labuan
Network
Pipelines
(km)
State
7,416,486
35,950
106,925
364,168
251,917
492,083
24,446
1,308,424
2,372,137
844,855
1,427,422
185,434
2,725
Population
ServedConnected
to STPs
3,683,985
92,045
298,800
751,055
165,275
149,965
15,600
183,350
471,445
924,050
24,430
552,960
55,010
Population
ServedSeptic Tanks+
Table 1 Details of sewerage systems operated and maintained by IWK as at December, 1997 [2]
11,100,471
127,995
405,725
1,115,223
417,192
642,048
40,046
1,491,774
2,843,582
1,768,905
1,451,852
738,394
57,735
Total
Population
Served
2
OOI SOON LEE, MOHD RAZMAN SALIM, MOHAMMAD ISMAIL & MD. IMTIAJ ALI
EXPERIMENTAL PROGRAMME
3.1
Materials Used
Untitled-30
02/16/2007, 17:20
OOI SOON LEE, MOHD RAZMAN SALIM, MOHAMMAD ISMAIL & MD. IMTIAJ ALI
Table 2
Chemical analysis
Percentage
20.20
5.70
3.00
62.50
2.60
1.80
0.16
0.87
2.70
Physical properties
Fineness specific surface are (m2/kg)
Soundness LeChatelier method (mm)
Specific gravity
314
1
3.28
and Grade 35 (G35) that based on same workability were cast using treated effluent.
Potable water was used in concrete cubes as the control specimens. Details of the
mix proportions are given in Table 3.
The test cubes were cast in 150 mm cast-iron moulds. The concrete was mixed
using pan mixer and fresh concrete was filled in the mould in three layers which was
compacted using vibrating table. The cube moulds were stored in a place free of
vibration and direct sunlight for 24 hours. At the end of this period, the mould was
removed and the cubes were cured in potable water until the age of testing.
Table 3 Mix proportion of concrete cubes
Mix Proportions (kg/m3)
Design Strength
(N/mm2)
Water
OPC
G30
G35
190
190
350
375
3.3
Aggregate
Fine
Coarse
730
1160
730
1140
W/C Ratio
0.54
0.51
Testing
A small portion of the treated effluent was retained for physical and chemical analysis. The characteristic of treated effluent and potable water were analysed according
to the methods described in the Standard Methods [14]. Heavy metals were analysed
using Atomic Adsorption Spectrophotometer while cations and anions were analysed
by Spectrophotometer DR4000. The cubes were tested for their compressive strength
Untitled-30
02/16/2007, 17:20
after curing periods of 7, 28, and 90 days for both G30 and G35. The TONIPACK
3000 was used to determine the compressive strength of concrete cubes with a loading rate at 7.0 kN/s. The strength of the cube was taken as the average of three cube
specimens.
For setting times, a cement paste was made with treated effluent and the ordinary
Portland cement. The test was carried out in accordance with BS4550 Part 3: Section
3.5 and Section 3.6 [1516]. The procedure also involved preliminary determination
of the amount of mixing water required to produce a cement paste of standard
consistence. Potable water was used as a control paste.
4.0
The physical and chemical properties of the treated effluent and potable water are
shown in Table 4. The treated effluent was slightly turbid (35 NTU) and faint yellowish-brown in colour. The total alkalinity, total hardness, sodium, and chloride
concentration are relatively higher compared to potable water. However, the concentration of the constituents of treated effluent were well within the respective tolerable limits from various researcher, as shown in Table 4.
Table 4
Parameter
pH
Total solid
Total suspended solid
Total alkalinity
mg/l
mg/l
mg/l as
CaCO3
mg/l
mgl
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
mg/l
Sulfate, SO42
Chloride, CI
Lead, Pb
Copper, Cu
Manganese, Mn
Zinc, Zn
Calcium, Ca
Magnesium, Mg
Sodium, Na
Ferum, Fe
Nitrate, NO32
Concentration
TE
7.48
89.5
17
PW
7.41
Tolerable
Limits
6.08.0
2000
2000
62
20
1000
10.49
11.98
N.D.
0.0817
0.124
0.0460
46.00
6.9
29.033
0.490
2.1
11.06
7.58
N.D.
0.0743
0.045
0.0378
0.17
2.2
1.317
0.153
2.9
1000
500
500
2000
(include
sulfate
and
chloride)
Untitled-30
02/16/2007, 17:20
References
McCoy [17]
White [7]
Mindness and
Young [18]
Neville [8]
BS3148 [11]
BS3148 [11]
Mindness
and Young
[18]
BS3148 [11]
OOI SOON LEE, MOHD RAZMAN SALIM, MOHAMMAD ISMAIL & MD. IMTIAJ ALI
Table 5 summarizes the result of compressive strength for the cubes mixed with
different mixing water. The cubes were tested on the 7th, 28th, and 90th day. The
compressive strength of cube mixed with treated effluent at 7-day was 26.22 N/mm2
compared to 24.46 N/mm2 of potable water. Similarly at 28-day, treated effluent
was 37.17 N/mm2 and 90-day was 41.24 N/mm2 compared to 33.20 N/mm2 and
38.27 N/mm2 of potable water, respectively.
Table 5 Compressive strength with different mixing water
Compressive Strength (N/mm2)
Grade
(N/mm2)
Age
(Day)
Mixing water
Potable water (fc) Treated effluent (ft)
Percentage of
increasing (%)
30
7
28
90
24.46
33.20
38.27
26.22
37.17
41.24
7.20
11.96
7.76
35
7
28
90
27.54
38.41
43.56
28.52
41.88
45.16
3.56
9.03
3.67
Meanwhile, the same observation was found for concrete cube G35. At curing
age of 7-day, treated effluent (28.52 N/mm2) was found to be slightly higher than
control specimen (27.54 N/mm2). The strength pattern for curing age of 28-day and
90-day were also similar as before, i.e. the strengths of treated effluent were higher
than the strengths of potable water.
Overall, a higher strength was obtained from specimens mixed with treated effluent than from control specimens. The increase is between 7.2 12.0% for G30 and
3.6 9.0% for G35 respectively. Higher compressive strength of concrete made with
a reclaimed wastewater as compored to concrete mixed with potable water was also
reported by Tay and Ng [19].
Figure 1 and Figure 2 show the development of compressive strengths for concrete cubes G30 and G35 at different ages respectively. All the graphs have similar
pattern shapes, that is, an increase in compressive strength was observed with an
increase of age. The results of overall compressive strength tests are found to be
consistent with the achieved design strength and the requirement stated in the BS
3148: 1980 [11]. The treated effluent seems to increase the compressive strength of
the concrete cubes compared to the control for both grades. The percentages of
increase in strength for treated effluent concrete cubes compared to the control
concrete cube are shown in Figure 3. The pattern of strength increase was almost
similar in both mixes. After 28 days of curing, the strength increase in concrete cube
cast with treated effluent was about 1.2 times than the control cubes for G30. The
Untitled-30
02/16/2007, 17:20
45
40
35
30
25
Potable
water
Potable water
20
Treated
effluent
Treated effluent
15
10
5
0
28
Age (day)
90
50
45
40
35
30
25
Potable
Water
Poteble water
20
Treated
Treated Effluent
Effluent
15
10
5
Percentage of strength
increasing (%)
7
7
28
28
Age (day)
90
90
14
12
10
G30
8
6
G35
Control
4
2
0
0
20
40
60
80
100
Age (days)
Untitled-30
02/16/2007, 17:20
OOI SOON LEE, MOHD RAZMAN SALIM, MOHAMMAD ISMAIL & MD. IMTIAJ ALI
data for G35 also indicated a trend similar to that of G30, except that the strength
increase in cube G30 was slightly higher than the cube of G35.
The increased in that was observed in this study may due to the higher concentration of sodium and calcium salt of chloride in treated effluent, compared to potable
water. Mindess and Young [18] reports that sodium chloride and calcium chloride
may increase early strength but reduce ultimate strength. Calcium chloride increases
the rate of heat liberation during the first few hours after mixing and acts as catalyst
in the reaction of hydration of C3S and C2S [8].
The results of setting time test are shown in Table 6. Initial and final setting times
are slightly higher for treated effluent paste compared to the control paste. This
probably due to the impurities in treated effluent such as zinc and copper salts
which varies in setting time process. Other salts that react actively as retarders include sodium iodate, sodium phosphate, sodium arsenate, and sodium borate [7].
The requirement of BS3148: 1980 for ordinary Portland cement stated that the
initial setting time should not be less than 75 minutes. The setting time for cement
paste mixed with treated effluent is well within the requirement of the standards.
Table 6 Setting time
Type of water
5.0
Final
Potable water
32
145
165
Treated effluent
32
155
170
CONCLUSIONS
From the results of this study, the properties of treated effluent used in this study
were found to be within the tolerable limits from the various researchers. Higher
compressive strength was achieved for concrete cube with treated effluent compared to the concrete cube with potable water. The initial and final setting times of
cement paste mixed with treated effluent increase compared with potable water.
The result obtained from this study indicates that treated effluent could be used as
mixing water in concrete in accordance with BS3184.
REFERENCES
[1]
[2]
[3]
Untitled-30
Indah Water Konsortium Sdn. Bhd., 1999. Developing A Modern & Efficient Sewerage System for Malaysia.
Kuala Lumpur: Indah Water Konsortium Sdn. Bhd.
Malaysia, Ministry of Housing and Local Government. 1997. Sewerage Services Report 1996 1997.
Kuala Lumpur: Sewerage Services Department.
Maeda, M., et al. 1996. Area-wide Use of Reclaimed Water in Tokyo, Japan. Wat. Sci. Tech. 33(10-11):
51 57.
02/16/2007, 17:20
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[18]
[19]
Untitled-30
Haarhoff, J. and B. Van der Merwe. 1996. Twenty-five Years of Wastewater Reclamation in Windhoek,
Namibia. Wat. Sci. Tech. 33(10-11): 25 35.
Friedler, E. 1999. The Jeezrael Valley Project for Wastewater Reclamation and Reuse, Israel. Wat. Sci.
Tech. 40(4-5): 347 354.
Mamlouk, M. S., and J. P. Zaniewski. 1999. Materials for Civil and Construction Engineers. California:
Addison Wesley Longman.
White, George R. 1991. Concrete Technology. 3rd edition. New York: Delmar Publishers.
Neville, A. M. 1995. Properties of Concrete. Fourth and Final Edition. England: Addison Wesley Longman.
Cebeci, O. Z. and A. M. Saatci. 1989. Domestic Sewage as Mixing Water in Concrete. ACI Materials
Journal. Sept.-Oct., 503 506.
Md Ghazaly Shaaban dan Ng, Lay Keong. 1993. Effect of Impurities in Mixing Waters on Cement/
Concrete Blocks Compressive Strength. Paper presented at National Seminar on Advances in Environmental Control Technology. Kuala Lumpur: Universiti Teknologi Malaysia. 1819 Ogos 1993.
British Standards Institution. 1980. Water for Making Concrete. BS3148. London: Bristish Standard Institution.
Department of Standards Malaysia. 1989. Standard Specification. MS522: Part1. Shah Alam: Dept. of
Standard Malaysia.
Department of the Environmental. 1988. Design of Normal Concrete Mixes. Watford, U.K.: Building Research Establishment.
APHA. 1992. Standard Methods for Examination of Water and Wastewater. New York: American Public-Health Association/American Water Works Association/Water Environment Federation.
British Standards Institution. 1991. Determination of Standard Consistence. BS4550: Part3: Section3.5. London: British Standard Institution.
British Standards Institution. 1991. Test for Setting Times. BS4550: Part3: Section3.6. London: British Standard Institution.
McCoy, W. J. 1978. Mixing and Curing Water for Concrete. ASTM Sp. Tech. Publ. 169B: 765 773.
Mindness, S., and J. F. Young. 1981. Concrete. New Jersey: Prentice-Hall.
Tay Joo Hwa, and Yi p Woon Kwong. 1987. Use of Reclaimed Wastewater for Concrete Mixing. Journal
of Environmental Engineering. 113(5): 1156 1161.
02/16/2007, 17:20