Aims
The aim of this experiment is to help students in understanding the half life, average
life, nature of radioactivity and isotope generator and the preference of half life over
average life.
Objective
The objective of this experiment is to determine the half life of Barium-137m.
Equipment
G.M counter, Cesium Barium generator, solution of HCl, Stopwatch. Timer Scalar.
Theory
• Radioactivity
Radioactivity is the process whereby unstable atomic nuclei release
energetic subatomic particles. The word radioactivity is also used to refer to the
1
subatomic particles themselves. This phenomenon is observed in the heavy elements, like
uranium, and unstable isotopes, like carbon-14.
Radioactivity was first discovered in 1896 by the French scientist Henri Becquerel,
after which the SI unit for radiation, the Becquerel, is named. Becquerel discovered that
uranium salts were able to blacken a photographic plate placed in the dark, even through
a paper barrier. Subsequent experiments distinguished three distinct types of radiation --
alpha particles, beta particles, and gamma rays. These are positively charged, negatively
charged, and neutral, respectively. In many countries, human exposure to radioactivity is
measured in rads, where one rad represents 0.01 joule of energy absorbed per kilogram of
tissue.
Radioactivity is a random process, meaning that it is physically impossible to
predict whether or not a given atomic nucleus will decay and emit radiation at any given
moment. Rather, radioactivity is quantified using half-life, which is the period of time it
takes for half of the given nuclei to decay. Half-life applies to a sample of any size, from
a microscopic quantity to all the atoms of that type in the universe. Half-life varies
widely, from a couple seconds (Astatine-218) to billions of years (Uranium-238).
2
Cesium
The metal is characterized by a spectrum containing two bright lines in the blue
(accounting for its name). It is silvery gold, soft, and ductile. It is the most electropositive
and most alkaline element. Cesium, gallium, and mercury are the only three metals that
are liquid at or around room temperature. Cesium reacts explosively with cold water, and
3
reacts with ice at temperatures above -116°C. Cesium hydroxide is a strong base and
attacks glass. Cesium reacts with the halogens to form a fluoride, chloride, bromide, and
iodide. Cesium metal oxidized rapidly when exposed to the air and can form the
dangerous superoxide on its surface.
Applications
Cesium is used in industry as a catalyst promoter, boosting the performance of
other metal oxides in the capacity and for the hydrogenation of organic compounds.
Cesium nitrate is used to make optical glasses. Cesium is sometimes used to remove
traces of oxygen from the vacuum tubes and from light bulbs. Cesium salts are used to
strength various types of glass. The chloride is used in photoelectric cells, in optical
instruments, and in increasing the sensitivity of electron tubes. Cesium is used in atomic
clocks and more recently in ion propulsion systems.
Although cesium is much less abundant than the other alkali metals, it is still
more common than elements like arsenic, iodine and uranium. Few cesium mineral are
know, pollucite is the main: they are silicate magmas cooled from granites.
World production of cesium compounds is just 20 tones per year, coming mainly from
the Bernic lake (Canada) with a little from Zimbabwe and South-West Africa.
The amount of cesium in foods and drinks depends upon the emission of radioactive
cesium through nuclear power plants, mainly through accidents. These accidents have not
occurred since the Chernobyl disaster in 1986. People that work in the nuclear power
industry may be exposed to higher levels of cesium, but many precautionary
measurements can be taken to prevent this.
It is not very likely that people experience health effects that can be related to cesium
itself. When contact with radioactive cesium occurs, which is highly unlikely, a person
can experience cell damage due to radiation of the cesium particles. Due to this, effects
such as nausea, vomiting, diarrhea and bleeding may occur. When the exposure lasts a
long time people may even lose consciousness. Coma or even death may than follow.
How serious the effects are depends upon the resistance of individual persons and the
duration of exposure and the concentration a person is exposed to.
4
Cesium occurs naturally in the environment mainly from erosion and weathering
of rocks and minerals. It is also released into the air, water and soil through mining and
milling of ores.
Radioactive isotopes of cesium may be released into the air by nuclear power plants and
during nuclear accidents and nuclear weapons testing.
Cesium in air can travel long distances before settling on earth. In water and soils most
cesium compounds are very water-soluble. In soils, however, cesium does not rinse out
into the groundwater. It remains within the top layers of soils as it strongly bonds to soil
particles and as a result it is not readily available for uptake through plant roots.
Radioactive cesium does have a chance of entering plants by falling on leaves.
Animals that are exposed to very high doses of cesium show changes in behaviour, such
as increased or decreased activity
Barium
5
Barium compounds are also used to make paint, bricks, tiles, glass, and rubber. Barium
nitrate and chlorate give fireworks a green color.
Barium enters the air during mining processes, refining processes, and during the
production of barium compounds. It can also enter the air during coal and oil combustion.
The chief mined ores are barite, which is also the most common and witserite. The main
mining areas are UK, Italy, Czech Republic, USA and Germany. Each year about 6
million tonnes are produced and reserves are expected to exceed 400 million tonnes.
Many hazardous waste sites contain certain amounts of barium. People that live
near them may be exposed to harmful levels. The exposure will than be caused by
breathing dust, eating soil or plants, or drinking water that is polluted with barium. Skin
contact may also occur.
The health effects of barium depend upon the water-solubility of the compounds.
Barium compounds that dissolve in water can be harmful to human health. The uptake of
very large amounts of barium that are water-soluble may cause paralyses and in some
cases even death.
Barium has not shown to cause cancer with humans. There is no proof that barium can
cause infertility or birth defects.
6
Because it forms insoluble salts with other common components of the environment,
such as carbonate and sulphate, barium is not mobile and poses little risk. Barium
compounds that are persistent usually remain in soil surfaces, or in the sediment of water
soils. Barium is found in most land soils at low levels. These levels may be higher at
hazardous waste sites.
Cesium-Barium Generator
Each generator contains 10 µCi of Cs-137, which represents one Exempt Quantity,
making it free from specific State and Federal licensing. The generator can produce up to
1000 small aliquots of the short-lived Ba-137m isotope with a half-life of 2.6 minutes.
Each generator is supplied with 250 mL of eluting solution (0.9% NaCl in 0.04M HCl).
The parent isotope Cs-137 with a half-life of 30.1 years beta decays (94.6%) to the
metastable state of Ba-137m. This further decays by gamma emission (662 keV) with a
half-life of 2.6 min. to the stable Ba-137 element. During elution, the Ba-137m is
selectively "milked" from the generator, leaving behind the Cs-137 parent. Regeneration
of the Ba-137m occurs as the Cs-137 continues to decay, re-establishing equilibrium in
less than 1 hour.
Approximately 30 minutes after elution, the residual activity of the Ba-137m sample has
decayed to less than one thousandth of its initial activity, making it safe for disposal.
When used with the eluting solution supplied, bleed through of the parent Cs-137 is less
7
than 50 Bq/mL, affording a long working life. Each kit is supplied with the generator,
syringe, tube, 250 mL of solution and a storage case.
Half Life
The half-life of a quantity whose value decreases with time is the interval required for
the quantity to decay to half of its initial value. The concept originated in describing how
long it takes atoms to undergo radioactive decay, but also applies in a wide variety of
other situations.
The term "half-life" dates to 1907. The original term was "half-life period", but that was
shortened to "half-life" starting in the early 1950s.
Half-lives are very often used to describe quantities undergoing exponential decay—for
example radioactive decay—where the half-life is constant over the whole life of the
decay. However, a half-life can also be defined for non-exponential decay processes,
although in these cases the half-life varies throughout the decay process. For a general
introduction and description of exponential decay, see the article exponential decay. For a
general introduction and description of non-exponential decay, see the article rate law.
8
The table shows the reduction of the quantity in terms of the number of half-lives
elapsed.
The radioactive half-life for a given radioisotope is the time for half the radioactive nuclei
in any sample to undergo radioactive decay. After two half-lives, there will be one fourth
the original sample, after three half-lives one eight the original sample, and so forth.
9
Formulae for half-life in exponential decay
A quantity is said to be subject to exponential decay if it decreases at a rate
proportional to its value. Symbolically, this can be expressed as the following differential
equation, where N is the quantity and λ is a positive number called the decay constant.
Here N(t) is the quantity at time t, and N0 = N(0) is the initial quantity,
An exponential decay process can be described by any of the following three equivalent
formulae:
Nt = N0e − t / τ
Nt = N0e − λt
where
• N0 is the initial quantity of the thing that will decay (this quantity
may be measured in grams, moles, number of atoms, etc.),
• Nt is the quantity that still remains and has not yet decayed after a
time t,
• t1 / 2 is the half-life of the decaying quantity,
10
• τ is a positive number called the mean lifetime of the decaying
quantity,
• λ is a positive number called the decay constant of the decaying
quantity.
The three parameters t1 / 2, τ, and λ are all directly related in the following way:
Regardless of how it's written, we can plug into the formula to get
11
Mean lifetime
The mean lifetime (also called the exponential time constant) is thus seen to be a simple
"scaling time":
Methodology
First prepare a solution of Cs-Ba by using the mini generator. fill your syringe with
eluting solution. Remove the stoppers on either end of the mini-generator column.
Hold the mini-generator carefully above the glass vial with the arrows on the mini-
generator pointing downward. While your partner holds the glass vial, insert the syringe
firmly into the hole on the top of the generator without pushing on the syringe plunger.
While carefully holding the mini-generator and the vial, use the syringe to force about 10
drops (1 mL) of solution into the mini-generator. DO NOT SUCK UP ON THE
SYRINGE; ONLY INSERT SOLUTION IN THE DIRECTION OF THE ARROWS ON
THE MINI-GENERATOR. This will release the barium 137m into the glass vial. Once
you’ve pushed the solution through, remove the syringe and place it and the mini-
generator carefully back on the table.
12
Place the sensor window of the Geiger counter directly next to the glass vial and you will
hear an increase in the level of radiation, this is the radioactive decay of barium 137m
into barium 137.
Repeat this at least 15 times and record all of your data on your table for a total of at least
15 data points.
Turn the Geiger counter off. Replace the stoppers on the two ends of the mini-generator
and return any remaining eluting solution from your syringe into the bottle from which
you removed it. Pour the contents of your glass vial into the HCl waste bottles, replace
the cover on the glass vial and leave it with the “dirty vials.”
13
Sr. # Time(min) Activity(Cpm)
1 1 935
2 2 745
3 3 534
4 4 452
5 5 359
6 6 291
7 7 250
8 8 193
9 9 204
10 10 160
11 11 157
12 12 130
13 13 132
14 14 109
15 15 110
Now using these readings I draw a graph and from that graph I calculated the half
life of Barium metastable.
For determining the half-life of Ba-137 take the activity at any time
from the graph and divide this activity by two. Note that the time duration between these
two activities is the half-life of Barium metastable.
14
Time , t1 = 1 min.
Half of the activity = 467.5 Cpm
Time , t2 = 3.6 min.
Half Life of Barium metastable = t2 − t1 = 3.6 - 1= 2.6 min.
Actual Half life of Barium = 2.551 min.
observed - actual
% error =
actual × 100%
2.6 - 2.551
% error = × 100%
2.551
% error = 1.9 %
15
• No food or drinks are allowed in this lab; leave all food outside the lab room.
• Safety goggles and gloves must be worn at all times when working with the
radioisotope generators.
• The eluting solution contains a weak concentration of HCl, this can cause burns
on your skin and clothing, please be careful to not spill it and wear gloves and
goggles at all times.
• Please do not touch the sensor window face plate on the Geiger counter; this can
ruin this expensive piece of equipment.
• Dispose of your used gloves in the trash and wash your hands thoroughly before
leaving the lab.
• Do not gather near the G.M counter otherwise it will not give you correct
readings.
• Quickly take the readings because it Ba-137m have a very short life.
• Be careful with the radiations because Beta radiations are very dangerous.
Discussion
All nuclei heavier than lead (and many isotopes of lighter nuclei) have a finite
probability of decaying spontaneously into another nucleus plus one or more lighter
particles. One of the decay products may be an alpha-particle (two protons and two
neutrons--the stable nucleus of a helium atom). Alternatively, a nucleus with more
neutrons than it can maintain in stability may decay by emission of an electron from the
nucleus (beta-decay) which corresponds to the conversion of a neutron to a proton.
These electrons may emerge with a kinetic energy of up to several MeV.After alpha or
16
beta decay, the residual nucleus may be left in an excited state. In this case, a transition
to a state of lower energy of the same nucleus will occur almost immediately with the
emission of a photon (gamma ray). The spectrum of photons emitted from the
various excited states of a nucleus will have discrete frequencies n, corresponding to
transitions ∆ E = hν , between discrete energy levels of the nucleus. The gamma ray
spectrum from an excited nucleus is thus analogous to the line spectrum of visible
radiation from an atom due to excited electrons, with the notable difference that the MeV
energy changes of the nucleus are 6approximately 10 times as large as energy changes
in transitions between atomic states (where ∆ E atomic several eV).
In early experiments on beta-decay, it was
observed that each decay was not a simple one in which an electron and the recoil
nucleus came off with equal and opposite momentum. The electrons, in fact, were
emitted with a continuous spectrum of energies . It was subsequently suggested by Pauli
and Fermi that in each decay, another particle of zero mass and charge, called the
neutrino, was emitted. Experimental verification of the neutrino has been obtained by
observation of its rare interaction with matter.
17
Questions and Answers
18
combination of nucleons and emits radiation in the process of regaining stability.
Reaching stability involves the process of radioactive decay. A decay, also known as a
disintegration of a radioactive nuclide, entails a change from an unstable combination of
neutrons and protons in the nucleus to a stable (or more stable) combination. The type of
decay determines whether the ratio of neutrons to protons will increase or decrease to
reach a more stable configuration. It also determines the type of radiation emitted.
How does the neutron-to-proton number change for each of these decay types?
Alpha decay typically occurs in nuclei that are so big that they can't be stable. In alpha
decay, the nucleus ejects a helium nucleus (alpha particle) composed of two neutrons and
two protons, dropping the mass of the original nucleus by four mass units. This smaller
nucleus is easier to keep in a stable form.
Beta decay?
In negative beta decay, the nucleus contains an excess of neutrons. To correct this
unstable condition, a neutron is converted into a proton, which keeps the nucleus the
same size (i.e., the same atomic mass) but increases the number of protons (and therefore
the atomic number) by one. In the process of this conversion, a beta particle with a
negative charge is then ejected from the nucleus.
Each one of these decay types may also involve the release of one or more photons of
gamma radiation. These photons are pure energy given off by the nucleus in its process of
achieving stability.
19
Is it possible to predict when a given radioactive atom will decay?
No, its not. The decay of an individual atom is a random event. However, it is possible to
predict when decay will occur based on probability, particularly when there are a lot of
radioactive atoms around. Fortunately, since atoms are so small, it doesn't take much
radioactive material to represent a lot of atoms.
Since the half-life is defined for the time at which 50% of the atoms have decayed,
why can't we predict when a particular atom of that element will decay?
The concept of half-life relies on a lot of radioactive atoms being present. As an example,
imagine you could see inside a bag of popcorn as you heat it inside your microwave
oven. While you could not predict when (or if) a particular kernel would "pop," you
would observe that after 2-3 minutes, all the kernels that were going to pop had in fact
done so. In a similar way, we know that, when dealing with a lot of radioactive atoms, we
can accurately predict when one-half of them have decayed, even if we do not know the
exact time that a particular atom will do so.
What else can you tell me about the half life of atoms?
Half-lives range from fractions of a second to billions of years. For example, Carbon-14
(C-14), a naturally occurring radionuclide, has a half-life of 5,730 years. After this
amount of time passes, half of the initial amount of C-14 is present. Therefore, if you
20
began with two (2) curies of C-14, one-half of that amount, or one curie, would be
present 5,730 years later. After two (2) half-lives, one-fourth of the initial activity, or 0.5
curies, would be left. After three (3) half-lives, which is more than 17,000 years later,
one-eighth of the original C-14 activity, or 0.25 curies, would remain, and so forth.
Well, 5,730 years seems like a long time to wait for the original C-14 activity to
diminish by 50%.
You're right. This points out the fact that the rate of decay of short-lived materials is
much faster than for their long-lived counterparts.
21
others like them, do not decay into other elements on a very frequent basis. For this
reason, their specific activities are considered to be low.
Where can I find a list of the specific activities of the various radionuclides?
The best place to start is the IEM "Tool Box" (on the left), under the section entitled
"Specific Activities". You'll find a pretty comprehensive listing there.
22
How can the concept of half-life be used to determine the age of organic materials?
Radiometric dating is a widely used technique that utilizes the half-life of radioactive
elements as a means to estimate the age of various materials. Several approaches are
used. Perhaps the most widely publicized has been radiocarbon dating.
Sounds impressive!
Considering that isotopes and decay rates were not known at this time is certainly cause
for amazement about these early studies!
Then what?
Radiocarbon dating relies on the assumption that C-14 exists in an "equilibrium"
concentration in the carbon of living biological materials, meaning the ratio of C-14 in
the body to that of stable Carbon, or C-12, stays constant. When a plant or animal dies, it
ceases breathing, eating, and/or absorbing carbon (and therefore C-14). Thus, the C-14-
to-C-12 ratio is no longer fixed. The C-14 begins to decay back into N-14, resulting in a
decrease in the C-14 concentration based on its half-life (a 50% reduction every 5,730
years). Since the rate of decay is known, the concentration (specific activity) of C-14 in
organic (carbon-containing) materials can be measured and used to calculate the date that
the plant or animal died.
23
Where is C-14 dating used?
Radiocarbon dating has been used to determine the age of certain fossilized bones. In
addition, this technique has been applied with great success in archaeological dating and
dating associated with the ice ages.
Anything more?
Yes indeed! There are still other interesting methods used in age-dating. One of these is
known as thermoluminescence.
24
purposes of this chapter, to the age of the material if the half-life is known (to account for
radioactive decay over periods of up to hundreds of thousands of years).
Why are radionuclides with short half-lives used most often in medical applications?
Medical procedures are designed, of course, to help the patient. When certain procedures
are performed utilizing radioactivity, it is advantageous and important from a health
perspective to use radionuclides that satisfy the desired diagnostic or treatment objective
and then decay away before they expose the patient to unnecessary amounts of radiation.
I've heard the term "biological half life" before. Is it different from the physical
half-life we have been discussing?
Most definitely. In contrast to the radiological (physical) half-life, the biological half-life
25
is a measure of how long it takes to eliminate half of the radioactivity taken into the body
by biological processes (e.g., excretion).
A curie is defined as 37 billion disintegrations per second. The curie was originally a
comparison of the activity of a sample to the activity of one gram of radium, which at the
time was measured as 37 billion disintegrations per second. A radioactive sample that has
an activity of 74 billion disintegrations per second, has an activity of 2 curies. When
more accurate techniques measured a slightly different activity for radium, the reference
to radium was dropped.
Henri Becquerel is credited with the discovery of beta particles. In 1900, he showed that
beta particles were identical to electrons, which had recently been discovered by Joseph
John Thompson.
Beta particles have an electrical charge of -1. Beta particles have a mass of 549 millionths
of one atomic mass unit, or AMU, which is about 1/2000 of the mass of a proton or
26
neutron. The speed of individual beta particles depends on how much energy they have,
and varies over a wide range. It is their excess energy, in the form of speed, that causes
harm to living cells. When transferred, this energy can break chemical bonds and form
ions.
Beta particle emission occurs when the ratio of neutrons to protons in the nucleus is too
high. In this case, an excess neutron transforms into a proton and an electron. The proton
stays in the nucleus and the electron is ejected energetically.
This process decreases the number of neutrons by one and increases the number of
protons by one. Since the number of protons in the nucleus of an atom determines the
element, the conversion of a neutron to a proton actually changes the radionuclide to a
different element.
Often, gamma ray emission accompanies the emission of a beta particle. When the beta
particle ejection doesn't rid the nucleus of the extra energy, the nucleus releases the
remaining excess energy in the form of a gamma photon.
The decay of technetium-99, which has too many neutrons to be stable, is an example of
beta decay. A neutron in the nucleus converts to a proton and a beta particle. The nucleus
ejects the beta particle and some gamma radiation. The new atom retains the same mass
number, but the number of protons increases to 44. The atom is now a ruthenium atom.
Other examples of beta emitters are phosphorous-32, tritium (H-3), carbon-14, strontium-
90, and lead-210.
There are many beta emitters. You can find fact sheets for several of them at the
Radionuclides page:
• tritium
• cobalt-60
• strontium-90
• technetium-99
• iodine-129 and -131
• cesium-137
Beta emitters have many uses, especially in medical diagnosis, imaging, and treatment:
• Iodine-131 is used to treat thyroid disorders, such as cancer and graves disease (a
type of hyperthyroidism)
27
• Phosphorus-32 is used in molecular biology and genetics research.
• Strontium-90 is used as a radioactive tracer in medical and agricultural studies.
• Tritium is used for life science and drug metabolism studies to ensure the safety
of potential new drugs. It is also used for luminous aircraft and commercial exit
signs, for luminous dials, gauges and wrist watches.
• Carbon-14 is a very reliable tool in dating of organic matter up to 30,000 years
old.
• Beta emitters are also used in a variety of industrial instruments, such as industrial
thickness gauges, using their weak penetrating power to measure very thin
materials.
Beta particles travel several feet in open air and are easily stopped by solid materials.
When a beta particle has lost its energy, it is like any other loose electron. Whether in the
outdoor environment or in the body, these electrons are then picked up by a positive ion.
There are both natural and man-made beta emitting radionuclides. Potassium-40 and
carbon-14 are weak beta emitters that are found naturally in our bodies. Some decay
products of radon emit beta particles, but its alpha-emitting decay products pose a much
greater health risk.
Beta emitters that eject energetic particles can pose a significant health concern. Their use
requires special consideration of both benefits and potential, harmful effects.
• Key beta emitters used in medical imaging, diagnostic and treatment procedures
are phosphorus-32, and iodine-131. For example, people who have taken
radioactive iodine will emit beta particles. They must follow strict procedures to
protect family members from exposure.
• Radioactive iodine may enter the environment during a nuclear reactor accident
and find its way into the food chain.
• Industrial gauges and instruments containing concentrated beta-emitting radiation
sources can be lost, stolen, or abandoned. If these instruments then enter the scrap
metal market, or someone finds one, the sources they contain can expose people
to beta emitters.
Yes. Direct exposure to beta particles is a hazard, because emissions from strong sources
can redden or even burn the skin. However, emissions from inhaled or ingested beta
particle emitters are the greatest concern. Beta particles released directly to living tissue
can cause damage at the molecular level, which can disrupt cell function. Because they
are much smaller and have less charge than alpha particles, beta particles generally travel
further into tissues. As a result, the cellular damage is more dispersed.
28
How can beta particles affect people's health?
Beta radiation can cause both acute and chronic health effects. Acute exposures are
uncommon. Contact with a strong beta source from an abandoned industrial instrument is
the type of circumstance in which acute exposure could occur. Chronic effects are much
more common.
Chronic effects result from fairly low-level exposures over a along period of time. They
develop relatively slowly (5 to 30 years for example). The main chronic health effect
from radiation is cancer. When taken internally beta emitters can cause tissue damage and
increase the risk of cancer. The risk of cancer increases with increasing dose.
Some beta-emitters, such as carbon-14, distribute widely throughout the body. Others
accumulate in specific organs and cause chronic exposures:
There are tests which can detect the presence of beta-emitting radionuclides in the body,
however, special equipment is required and testing is generally done by specialized
laboratories and facilities, or such testing is associated with a specific medical procedure
in a hospital.
You cannot tell if you are being exposed to beta radiation. You cannot see, or feel
radiation hitting your body. Specialized equipment is required to determine if
you are near a beta radiation source. However, you should be familiar with the
radiation warning symbols such as the trefoil shown at right, which indicate that
radioactivity is present.
You can protect yourself by avoiding devices with this symbol, and not entering areas
where this symbol or others are posted.
While very unlikely, you or a member of your family may encounter an industrial
instrument or device containing a radioactive source. Every year, hundreds of devices
containing radiation sources are lost, stolen, or otherwise drop out of the system for
tracking them. For example, a factory that has gone out of business may contain one or
more such devices. As the building structure is being dismantled, these forgotten devices
often are considered as scrap metal, or someone may think they have value and try to sell
them.
29
You should avoid these devices. They may bear the radiation warning symbol, a trefoil,
as shown above. They may also bear identifying information such as "Nuclear Regulatory
Commission" or the name of a radionuclide. If you find a device you think may be
radioactive, promptly call your state radiation control office or the hotline for reporting
unwanted radioactive material.
Aims
The aim of this experiment is to make students familiar in a true sense with the
radioactive equilibrium, its types i.e. Secular and Transient Equilibrium. Also to make the
students familiar with the concept of decay and growth rate of radioactive elements.
Objective
The objective of this experiment is to determine the type of equilibrium for
Barium-137.
30
Equipment
G.M counter, Cesium Barium generator, solution of HCl, Stopwatch. Timer Scalar.
Theory
Half Life
The half-life of a quantity whose value decreases with time is the interval required for
the quantity to decay to half of its initial value. The concept originated in describing how
long it takes atoms to undergo radioactive decay, but also applies in a wide variety of
other situations.
The term "half-life" dates to 1907. The original term was "half-life period", but that was
shortened to "half-life" starting in the early 1950s.
Half-lives are very often used to describe quantities undergoing exponential decay—for
example radioactive decay—where the half-life is constant over the whole life of the
decay. However, a half-life can also be defined for non-exponential decay processes,
although in these cases the half-life varies throughout the decay process. For a general
introduction and description of exponential decay, see the article exponential decay. For a
general introduction and description of non-exponential decay, see the article rate law.
The table shows the reduction of the quantity in terms of the number of half-lives
elapsed.
31
Probabilistic nature of half-life
A half-life often describes the decay of discrete entities, such as radioactive atoms.
In that case, it does not work to use the definition "half-life is the time required for
exactly half of the entities to decay". For example, if there is just one radioactive atom
with a half-life of 1 second, there will not be "half of an atom" left after 1 second. There
will be either zero atoms left or one atom left, depending on whether or not the atom
happens to decay.
Instead, the half-life is defined in terms of probability. It is the time when the expected
value of the number of entities that have decayed is equal to half the original number. For
example, one can start with a single radioactive atom, wait its half-life, and measure
whether or not it decays in that period of time. Perhaps it will and perhaps it will not. But
if this experiment is repeated again and again, it will be seen that it decays within the half
life 50% of the time.
In some experiments (such as the synthesis of a superheavy element), there is in fact only
one radioactive atom produced at a time, with its lifetime individually measured. In this
case, statistical analysis is required to infer the half-life. In other cases, a very large
number of identical radioactive atoms decay in the time-range measured. In this case, the
central limit theorem ensures that the number of atoms that actually decay is essentially
equal to the number of atoms that are expected to decay. In other words, with a large
enough number of decaying atoms, the probabilistic aspects of the process can be
ignored.
There are various simple exercises that demonstrate probabilistic decay, for example
involving flipping coins or running a computer program.
The radioactive half-life for a given radioisotope is the time for half the radioactive nuclei
in any sample to undergo radioactive decay. After two half-lives, there will be one fourth
the original sample, after three half-lives one eight the original sample, and so forth.
32
Formulae for half-life in exponential decay
A quantity is said to be subject to exponential decay if it decreases at a rate
proportional to its value. Symbolically, this can be expressed as the following differential
equation, where N is the quantity and λ is a positive number called the decay constant.
Here N(t) is the quantity at time t, and N0 = N(0) is the initial quantity,
An exponential decay process can be described by any of the following three equivalent
formulae:
Nt = N0e − t / τ
Nt = N0e − λt
where
• N0 is the initial quantity of the thing that will decay (this quantity
may be measured in grams, moles, number of atoms, etc.),
• Nt is the quantity that still remains and has not yet decayed after a
time t,
• t1 / 2 is the half-life of the decaying quantity,
• τ is a positive number called the mean lifetime of the decaying
quantity,
• λ is a positive number called the decay constant of the decaying
quantity.
33
The three parameters t1 / 2, τ, and λ are all directly related in the following way:
Regardless of how it's written, we can plug into the formula to get
34
Mean lifetime
The mean lifetime (also called the exponential time constant) is thus seen to be a simple
"scaling time":
Radioactive Equilibrium
Radioactive equilibrium for a decay chain occurs when the each radionuclide decays
at the same rate it is produced. At equilibrium, all radio nuclides decay at the same rate.
Understanding the equilibrium for a given decay series, helps scientists estimate the
amount of radiation that will be present at various stages of the decay.
For example, as uranium-238 begins to decay to thorium-234, the amount of thorium and
its activity increase. Eventually the rate of thorium decay equals its production--its
concentration then remains constant. As thorium decays to proactinium-234, the
concentration of proactinium-234 and its activity rise until its production and decay rates
are equal. When the production and decay rates of each radionuclide in the decay chain
are equal, the chain has reached radioactive equilibrium.
Equilibrium occurs in many cases. However if the half-life of the decay product is much
longer than that of the original radionuclide, equilibrium cannot occur. The graphs below
illustrate the progress of ingrowth, and its effect on overall activity, and the potential for
radioactive equilibrium in three general cases.
35
We considered briefly a special case in which a radioactive daughter substance was
formed in the decay of the parent. Let us take up the general case for the decay of a
radioactive species, denoted by subscript 1, to produce another radioactive species,
denoted by subscript 2.
The behavior of N1 is just as has been derived; that is,
dN1
− = λ1N1
dt
and
N1 = N10 e −λ1t
where we use the symbol N1 to represent the value of N1 at t = 0.
0
Now the second species is formed at the rate at which the first decays, λ1N1 , and itself
decays at the rate λ2N2 . Thus
dN2
= λ1N1 − λ2N2
dt
dN2
= λ1N10 e −λ1t − λ2N2
dt
dN2
+ λ2N2 = λ1N10 e −λ1t
dt
dN2 ( t )
e λ2 t + λ2N2e λ2t = λ1N10 e ( λ2 −λ1 ) t
dt
what to be rewritten:
d
dt
( N2e λ2t ) = λ1N10e ( λ2 −λ1 ) t
Integrating:
λ1
N2e λ2t = N10 e ( λ2 −λ1 ) t + C
λ 2 − λ1
λ1
N2 = N10 e −λ1t + Ce −λ2t
λ 2 − λ1
for t=0, N2 = N2 :
0
λ1
C=− N10 + N20
λ 2 − λ1
36
λ1
N2 = N10 ( e −λ1t − e −λ2t ) + N20 e −λ2t
λ 2 − λ1 (2)
dN2
− λ1N1 + λ2N2 = 0
The solution of dt this linear differential equation of the first order
may be obtained by standard methods and gives
λ1
N2 = N10 ( e −λ1t − e −λ2t ) + N20 e −λ2t
λ 2 − λ1
where N2 is the value of N2 at t = 0. Notice that the first group of terms shows the
0
growth of daughter from the parent and the decay of these daughter atoms; the last term
gives the contribution at any time from the daughter atoms present initially.
In applying (2) to considerations of radioactive (parent and daughter) pairs, we can
distinguish two general cases, depending on which of the two substances has the longer
half life.
If the parent is longer-lived than the daughter (λ1<λ2), a state of so-called radioactive
equilibrium is reached; that is, after a certain time the ratio of the numbers of atoms and,
consequently, the ratio of the disintegration rates of parent and daughter become constant.
This can be readily seen from (2); after t becomes sufficiently large, e
−λ2 t
is negligible
compared with e , and N2 e
−λ1t 0 −λ2 t
also becomes negligible; then
λ1
N2 = N10 e −λ1t
λ 2 − λ1
and, since N1 = N1 e
0 −λ1 t
N1 λ1
=
N2 λ2 − λ1 (3)
The relation of the two measured activities is found from A1 = c1λ1N1 , A2 = c2λ2N2 to be
A1 c1 ( λ2 − λ1 )
=
A2 c2λ2 (4)
In the special case of equal detection coefficients (c1=c2) the ratio of the two activities,
A1 λ
=1− 1
A2 λ2 ,
may have any value between 0 and 1, depending on the ratio of λ1 to λ2 that is, in
equilibrium the daughter activity will be greater than the parent activity by the factor λ2/
( λ2 – λ1).
In equilibrium both activities decay with the parent's half life.
37
As a consequence of the condition of transient equilibrium (λ2>λ1), the sum of the parent
and daughter disintegration rates in an initially pure parent fraction goes through a
maximum before transient equilibrium is achieved.
This situation is illustrated in figure 2.
Figure 2 - Transient equilibrium: (a) total activity of an initially pure parent fraction; (b)
activity due to parent (t1/ 2 = 8.0 h); (c) decay of freshly isolated daughter fraction (t1/ 2
= 0.80 h); (d) daughter activity growing in freshly purified parent fraction; (e) total
daughter activity in parent-plus-daughter fractions
38
The more general condition for the total measured activity (A1+A2) of an initially pure
parent fraction to exhibit a maximum is found to be c2/c1 > λ1/λ2. This condition holds
( λ2 − λ1 ) c2 λ1
≤ ≤
regardless of the relative magnitudes of λ1, and λ2. The λ2 c1 λ2 condition
will give a maximum in the total measured activity that occurs at a negative time.
N1 λ1
=
N2 λ2 or λ1N1 = λ2N2
39
Figure 3 - Secular equilibrium: (a) total activity of an initially pure parent fraction; (b)
activity due to parent (t1/2 = ∞ ); this is also the total daughter activity in parent-plus-
daughter fractions; (c) decay of freshly isolated daughter fraction (t1 / 2 = 0.8h ); (d)
daughter activity growing in freshly purified parent fraction.
If the parent is shorter-lived than the daughter (λ1>λ2), it is evident that no equilibrium is
attained at any time. If the parent is made initially free of the daughter, then as the parent
decays the amount of daughter will rise, pass through a maximum, and eventually decay
with the characteristic half life of the daughter. This is illustrated in figure 4; for this plot
we have taken λ1/λ2= 10, and c1=c2. In the figure the final exponential decay of the
daughter is extrapolated back to t=0.
Figure 4 - The case of no equilibrium: (a) total activity; (b) activity due to parent (
t1 / 2 = 0.8h ); (c) extrapolation of final decay curve to time zero; (d) daughter activity in
initially pure parent.
This method of analysis is useful if λ1 ? λ2 , for then this intercept measures the activity
c2λ2N10 the N10 atoms give rise to N2 atoms so early that N10 may be set equal to the
extrapolated activity gives the ratios of the half lives if the relation between c1 and c2 is
known:
40
t1
c1λ1N10 c1 λ1 2 2
= x =
c2λ2N10 c2 λ2
t1
2 1
If λ2 is not negligible compared to λ1, it can be shown that the ratio λ1/λ2 in this
( λ1 − λ 2 )
equation should be replaced by λ2 and the expression involving the half lives
changed accordingly.
Both the transient-equilibrium and the no-equilibrium cases are sometimes analyzed in
terms of the time tm for the daughter to reach its maximum activity when growing in a
freshly separated parent fraction.
This time we find from the general equation (2) by differentiating,
dN2 λ12 λ1 λ 2
= N10 e −λ1t + N10 e −λ2t
dt ( 2 1)
λ − λ ( 2 1)
λ − λ
dN2
=0
and setting dt when t = tm:
λ2 1 λ
= e ( λ2 −λ1 ) tm tm = ln 2
λ1 or λ 2 − λ 1 λ1
At this time the daughter decay rate λ2N2 is just equal to the rate of formation λ1N1 , [this
is obvious from (1)]; in figures 2 and 4, in which we assumed c1=c2, we have the parent
activity A1 intersecting the daughter growth curve d at the time tm. (The time tm is
infinite for secular equilibrium.)
41
Transient Equilibrium
When the half-life of the original radionuclide is only slightly longer or about the
same as the half life of the decay product, the total activity rises initially. This results
from the combined decay of both radio nuclides. (It peaks slightly before the activity of
the decay product does.) Eventually a balance (equilibrium) is reached.
The total activity then decays at about the same rate as the original radionuclide. This is
known as "transient equilibrium."
42
Secular Equilibrium
When the half-life of the original radionuclide is much longer than the half-life of the
decay product, the decay product generates radiation more quickly. Within about 7 half
lives of the decay product, their activities are equal, and the amount of radiation (activity)
is doubled. Beyond this point, the decay product decays at the same rate it is produced--a
state called "secular equilibrium."
43
No Equilibrium
If the half-life of the decay products is much longer than that of the original
radionuclide, its activity builds up to a maximum and then declines. The original
radionuclide eventually decays away and no equilibrium occurs.
Methodology
First prepare a solution of Cs-Ba by using the mini generator. fill your syringe with
eluting solution. Remove the stoppers on either end of the mini-generator column.
Hold the mini-generator carefully above the glass vial with the arrows on the mini-
generator pointing downward. While your partner holds the glass vial, insert the syringe
firmly into the hole on the top of the generator without pushing on the syringe plunger.
While carefully holding the mini-generator and the vial, use the syringe to force about 10
drops (1 mL) of solution into the mini-generator. DO NOT SUCK UP ON THE
SYRINGE; ONLY INSERT SOLUTION IN THE DIRECTION OF THE ARROWS ON
THE MINI-GENERATOR. This will release the barium 137m into the glass vial. Once
44
you’ve pushed the solution through, remove the syringe and place it and the mini-
generator carefully back on the table.
Place the sensor window of the Geiger counter directly next to the glass vial and you will
hear an increase in the level of radiation, this is the radioactive decay of barium 137m
into barium 137.
Repeat this at least 15 times and record all of your data on your table for a total of at least
15 data points.
Turn the Geiger counter off. Replace the stoppers on the two ends of the mini-generator
and return any remaining eluting solution from your syringe into the bottle from which
you removed it. Pour the contents of your glass vial into the HCl waste bottles, replace
the cover on the glass vial and leave it with the “dirty vials.”
45
Observations and Calculations
46
Time to reach Equilibrium Point
After five half lives the graph of decay and growth become parallel to each other
So time, T after which equilibrium will established is
T = 5t 1
2
since half life of Ba = 2.6
so T = 5 × 2.6
T = 13 min.
935 + 291
So t1 = 6 min , N1 = = 613
2
1 291
Thus λ1 = ln
6 613
λ1 = −0.1241
1 A12
Now λ2 = ln
t2 A1
47
1 130
λ2 = ln
12 613
λ2 = −0.1292
For Transient Equilibrium
The condition for the Transient Equilibrium is
N2 λ1
=
N1 λ2 − λ1
λ1 −0.1241
Now =
λ2 − λ1 −0.1291 + 0.1241
λ1 −0.1241
=
λ2 − λ1 −5.1×10−3
λ1
= 0.024 × 103
λ2 − λ1
λ1
= 24
λ2 − λ1
Now
A1 + A6
N1 =
2
935 + 291
N1 =
2
N1 = 613
A + A12
and N2 = 1
2
935 + 130
N2 = = 532.5
2
N 2 532.5
So =
N1 613
N2
= 0.86
N1
N2 λ1
For Transient Equilibrium the condition = must be satisfied but from
N1 λ2 − λ1
N2 λ1
above results = 0.86 and = 24 .
N1 λ2 − λ1
i.e. 0.86 ≠ 24
thus we can say that Transient Equilibrium is not established.
48
For Secular Equilibrium
The condition for the Secular Equilibrium is
λ1 N 2
=
λ2 N1
So
λ1 −0.1241
= = 0.9605
λ2 −0.1292
And
N2
= 0.86
N1
Since 0.86 ; 0.96
Thus we can say that Secular Equilibrium has been established.
49
Precautions and Sources of Errors
Lab uses a sealed radioactive source. Within this mini-generator is radioactive cesium
with a half-life of about 30 years. Because this source is sealed, you will not come into
contact with this cesium unless the mini-generator is broken. Therefore, please be careful
handling this piece of equipment. The radioactive barium that you will be working with
today has a very short half-life. By the time the lab is over today, more than 10 half-lives
will have passed, at which point the radioactivity levels are equal to the background
radioactivity normally present in the air. Therefore, this radioactive source is very safe to
work with AS LONG AS THE FOLLOWING SAFETY
• No food or drinks are allowed in this lab; leave all food outside the lab room.
• Safety goggles and gloves must be worn at all times when working with the
radioisotope generators.
• The eluting solution contains a weak concentration of HCl, this can cause burns
on your skin and clothing, please be careful to not spill it and wear gloves and
goggles at all times.
• Please do not touch the sensor window face plate on the Geiger counter; this can
ruin this expensive piece of equipment.
• Dispose of your used gloves in the trash and wash your hands thoroughly before
leaving the lab.
• Do not gather near the G.M counter otherwise it will not give you correct
readings.
• Quickly take the readings because it Ba-137m have a very short life.
• Be careful with the radiations because Beta radiations are very dangerous.
50
Questions and Answers
Question 1
Match the origination of the radionuclide with the most appropriate decay mode.
Answer:
A-ii Adding neutrons to nuclei results in excess neutrons which leads to beta minus
decay;
B-iii; Adding protons to nuclei requires them to lose their excess positive charge by
positron emission or electron capture;
C-i; 226Ra is an alpha emitter which decays to form radon (222Rn).
Question 2
(A) is secular when the half-life of the parent » half-life of the daughter
(B) requires about 6 half-lives for secular equilibrium to be established
(C) is transient if the half-life of the parent is > half-life of the daughter
(D) for a 99Mo/99mTc generator may be termed transient
(E) is established in 24 hours for a 99Mo/99mTc generator.
Answer:
A-True;
B-True;
C-True;
D-True
E-True.
Question 3
For 99mTc decaying to 99Tc, all of the following are true EXCEPT
51
(B) the half-life of 99Tc is 2.l x 105 years
(C) activity is N x lambda (N = number of atoms; lambda is decay constant)
(D) lambda= 0.693/T1/2 where T1/2 is the half-life
Answer:
A.
The half life of 99mTc is 6 hours. The parent of 99mTc, 99Mo has a half-life of 67 hours.
Question 4
If 100 mCi 99mTc is "milked" from a 99Mo generator (at equilibrium) at 9 A.M. on
Monday, then
Answer:
B.
It takes about 24 hours for transient equilibrium to be established between the
99Mo/99mTc. The activity of 99Mo will be 80 mCi since it decays with a half-life of 67
hours.
Question 5.
Answer:
E.
An ideal radiopharmaceutical would have all of these properties.
Question 6.
The radiation level adjacent to the one week-old 99Mo/99mTc generator depends on
all of the following EXCEPT the
52
(B) number of times the generator was milked
(C) amount of Pb shielding around the generator
(D) amount of 99Mo remaining
(E) distance from the generator
Answer:
B.
Elutions only affect the amount of 99mTc in the generator and since the 99mTc photon
energy (140 keV) is very low, this will not contribute significantly to the measured
radiation level outside the shielded generator.
Question 7.
Technetium-99m generators CANNOT be
Answer:
A.
99Mo may be produced in a reactor or from fission products, but cannot be produced in a
cyclotron since 99Mo is a beta emitter requiring the addition of neutrons, not protons.
Question 8.
Match the following half-lives with the appropriate radionuclide.
(A) 2 minutes
(B) 110 minutes
(C) 13 hours
(D) 67 hours
(E) 8 days
(i) Fluorine-18
(ii) Molybdenum-99
(iii) Iodine-123
(iv) Iodine-131
(v) Oxygen-15
Answer:
A-v
B-i
C-iii
D-ii
E-iv
53
Question 9.
Gamma camera crystals
Answer:
E.
A typical Nal crystal thickness of 10 mm absorbs over 90% of the 140 keV photons via
the photoelectric effect.
Question 10.
The pulse height analyzer in a gamma camera system
Answer:
B.
The pulse height analyzer measures the total energy deposited in the photon interaction
and "accepts" only photopeak interactions that correspond to a photoelectric interaction
with the full photon energy.
Question 11.
Match the typical resolution at full width half maximum (FWHM) with the
detection system.
(i) 3mm
(ii) 5mm
(iii) 7.5 mm
(iv) 10 mm
Answer:
54
A-i
B-iv
C-iii
D-ii
Question 12.
For each clinical application, match the best collimator.
(i) Diverging
(ii) Parallel hole
(iii) Converging
(iv) Pinhole
Answer:
A-iv; thyroid studies are normally performed using pinhole collimators to improve
resolution;
B-iii; converging collimator is used in pediatric studies to magnify the image;
C-i; diverging collimators minify the image and permit both lungs to be visualized in a
single image;
D-ii; liver scans are normally performed with an all-purpose or high-resolution parallel
hole collimator.
Question 13.
For parallel hole collimators, which of the following improves as the distance from
the face of the collimator is increased?
(A) Resolution
(B) Sensitivity
(C) Energy resolution
(D) Imaging time
(E) None of the above
Answer:
E.
None of these factors improve. In clinical practice, it is important to minimize the patient
collimator distance.
Question 14.
Nuclear medicine images acquired using a computer typically have
55
(B) matrix sizes of 64 x 64 or 128 x 128
(C) 256 gray scale levels
(D) 4 to 16 kBytes of image data
(E) all of the above
Answer:
E.
All of the statements are true.
Question 15.
In general, gamma camera system resolution with a parallel-hole collimator
Answer:
E.
All of the statements are true.
Question 16.
The system resolution of a gamma camera with a parallel hole collimator improves
with increased collimator
Answer:
B.
Increasing collimator thickness improves resolution but reduces sensitivity.
Question 17.
Thyroid imaging studies can be performed with all of the following EXCEPT
56
Answer:
B.
An uptake probe measures the total amount of activity in the thyroid but does not
generate any kind of image.
Question 18.
A circular cold spot artifact in a gamma camera image could NOT be the result of
Answer:
A.
A cracked Nal crystal would give rise to a linear artifact, not a circular one.
Question 19.
Match the following half-life relationships.
Answer:
A-iv
B-ii;
C-iii;
D-i.
All of these follow from the definition of effective half-life 1/Te = 1/T1/2 + 1/Tb.
Question 20.
When 99mTc is administered to a patient, which of the following CANNOT
contribute to the patient dose?
57
(E) Characteristic x-rays
Answer:
B.
There are no beta particles associated with 99mTc.
Question 21.
Which of the following statements regarding radioiodine and the fetal thyroid are
true?
Answer:
E.
All of the statements are true.
Question 22.
True (T) or False (F).
For patients undergoing typical nuclear medicine procedures
Answer:
A-True;
B-False; typical HE for a PA chest x-ray is 20 microSv (2 mrem);
C-True;
D-True; although positron emitters are much shorter lived, they deposit much more
energy per decay, and these two factors cancel each other out;
E-False; patient dose is determined by the amount of activity administered, and
"imaging" time is irrelevant to patient dose.
Question 23.
An ideal therapeutic radionuclide (e.g.32P) would have
58
(E) all of the above
Answer:
E.
All these characteristics are desirable in a therapeutic radionuclide because they
maximize the organ dose and minimize external radiation hazards from gamma rays.
Question 24.
Match the following image characteristics with the appropriate equipment.
Answer:
A-iv; edge packing is observed at the edge of nuclear medicine images;
B-iii; line bar phantoms are used to ensure that the image is as straight as the object;
Cii; gamma camera uniformity is assessed using flood sources;
D-i; distortion may result from a damaged collimator.
Question 25.
Low-level radioactive wastes, such as tubing and swabs contaminated with 99mTc,
may be monitored with
Answer:
A.
Geiger-Mtiller counters are generally used to monitor low-level waste because of their
high sensitivity, portability, and immediate responses.
Question 26.
Match the radionuclide impurity with the corresponding radioactive material.
59
(D) 201Tl
(i) 99Mo
(ii) 124I
(iii) 202Tl
(iv) None
Answer:
A-ii;
B-i; 99Mo may be eluted from the column;
C-iv; 67Ga is produced in a cyclotron from 67Zn and has no radiochemical impurities;
D-iii.
Question 27.
True (T) or False (F).
Single photon emission computed tomography (SPECT) normally requires
Answer:
A-False; positron emitters are required for PET imaging;
B-True; projections are normally obtained through 360 degrees around the patient;
C-False; annihilation radiation in PET is obtained using coincidence detection;
D-True; this is required to minimize the amount of scatter accepted;
E-True; filtered back projection algorithms are used in SPECT;
F-False; this is occasionally done in PET to obtain absolute quantitative physiological
data.
Question 28.
For SPECT, all the following are true - EXCEPT
Answer:
C.
60
Patient motion correction is not normally performed for SPECT imaging. Digital
subtraction angiography imaging software sometime permits corrections to be made for
patient motion.
Question 29.
Advantages of PET over conventional gamma camera imaging include
(A) a wider choice of molecules that may be labeled with positron emitters
(B) better resolution
(C) lower image noise
(D) rapid decay of radiopharmaceutical
(E) all of the above
Answer:
E.
All of the statements are generally true in PET imaging.
Question 30.
PET imaging systems
Answer:
D
Two 511 keV photons are emitted 180 degrees apart, which are detected by a coincidence
circuit.
61
To determine the absorption coefficient of lead for
Gamma Rays using GM counter.
Aims
The purpose of this experiment is to investigate various radiation phenomena using a
Geiger-Mueller counter. The aim of this experiment is to illustrate
Objective
To study the behavior of gamma rays and to determine the absorption coefficient in
lead of the gamma radiation from the given source.
Equipment
G.M counter, Cesium Barium generator, solution of HCl, Stopwatch, Timer Scalar,
led slides.
62
Theory
Gamma Radiations
Gamma rays (often denoted by the Greek letter gamma, γ) are an energetic form
of electromagnetic radiation produced by radioactivity or other nuclear or subatomic
processes such as electron-position annihilation. Gamma rays are more penetrating than
either alpha or beta radiation, but less ionizing. Gamma rays are distinguished from X
rays by their origin. Gamma rays are produced by nuclear transitions while X-rays are
produced by energy transitions due to accelerating electrons. Because it is possible for
some electron transitions to be of higher energy than nuclear transition, there is an
overlap between low energy gamma rays and high energy X-rays.
Shielding for γ rays requires large amounts of mass. Shields that reduce gamma ray
intensity by 50% include 1 cm (0.4 inches) of lead, 6 cm (2.4 inches) of concrete or 9 cm
(3.6 inches) of packed dirt.
Gamma rays from nuclear fallout would probably cause the largest number of casualties
in the event of the use of nuclear weapons in a nuclear war. An effective fallout shelter
reduces human exposure at least 1000 times.
Gamma rays are less ionizing than either alpha or beta rays. However, reducing human
danger requires thicker shielding. They produce damage similar to that caused by X-rays
such as burns, cancer, and genetic mutations.
In terms of ionization, gamma radiation interacts with matter via three main processes:
the photoelectric effect, Compton scattering, and pair production.
Photoelectric Effect: This describes the case in which a gamma photon interacts with
and transfers all of its energy to an orbital electron, ejecting that electron from the atom.
The kinetic energy of the resulting photoelectron is equal to the energy of the incident
gamma photon minus the binding energy of the electron. The photoelectric effect is
63
thought to be the dominant energy transfer mechanism for x-ray and gamma ray photons
with energies below 50 keV (thousand electron volts), but it is much less important at
higher energies.
Pair Production: By interaction in the vicinity of the coulomb force of the nucleus, the
energy of the incident photon is spontaneously converted into the mass of an electron-
positron pair. A positron is a positively charged electron. Energy in excess of the
equivalent rest mass of the two particles (1.02 MeV) appears as the kinetic energy of the
pair and the recoil nucleus. The electron of the pair, frequently referred to as the
secondary electron, is densely ionizing. The positron has a very short lifetime. It
combines within 10-8 second with a free electron. The entire mass of these two particles is
then converted to two gamma photons of 0.51 MeV energy each.
Gamma rays are often produced alongside other forms of radiation, such as alpha or beta.
When a nucleus emits an α or β particle, the daughter nucleus is sometimes left in an
excited state. It can then jump down to a lower level by emitting a gamma ray in much
the same way that an atomic electron can jump to a lower level by emitting ultraviolet
radiation.
Gamma rays, x-rays, visible light, and UV rays are all forms of electromagnetic radiation.
The only difference is the frequency and hence the energy of the photons. Gamma rays
are the most energetic. An example of gamma ray production follows.
Then the nickel-60 drops down to the ground state by emitting a gamma ray:
The probability of each of the three processes taking place in a given thickness of
material depends on the energy of the photon and the atomic structure of the material.
The total probability for interaction of photons in Pb, i.e., the sum of the probabilities of
64
the three processes, varies with photon energy as indicated in Figure . The ordinate
plotted on the graph is μ, the total linear absorption coefficient in units of cm −1 . It is
defined by the equation:
dN
= −µ N
dx
where N is the number of incident photons and dN is the number removed from the beam
(i.e. absorbed) in an absorber of thickness dx (in cm). Note that dN and dx are the
calculus equivalents of infinitesimally small values of ΔN and Δx, respectively. As in
any process where the rate of decrease is proportional to the number present (such as the
discharge of a capacitor), the solution of this differential equation is:
N ( x) = N 0e − µ x
where N(x) is the number of photons passing through x cm of absorber and N 0 = N ( x )
at x = 0 and e is the base of natural logarithms.
The K absorption edge of lead is at 88keV yet it emits X-rays at only 75keV.
65
Gamma-ray astronomy
Gamma-ray astronomy is the astronomical study of gamma rays.
Long before experiments could detect gamma rays emitted by cosmic sources, scientists
had known that the universe should be producing these photons. Work by Feenberg and
Primakoff in 1948, Hayakawa and Hutchinson in 1952, and, especially, Morrison in 1958
had led scientists to believe that a number of different processes which were occurring in
the universe would result in gamma-ray emission. These processes included cosmic ray
interactions with interstellar gas, supernova explosions, and interactions of energetic
electrons with magnetic fields. However, it was not until the 1960s that our ability to
actually detect these emissions came to pass.
Gamma-rays coming from space are mostly absorbed by the Earth's atmosphere. So
gamma-ray astronomy could not develop until it was possible to get our detectors above
all or most of the atmosphere, using balloons or spacecraft. The first gamma-ray
telescope carried into orbit, on the Explorer-XI satellite in 1961, picked up fewer than
100 cosmic gamma-ray photons. These appeared to come from all directions in the
Universe, implying some sort of uniform "gamma-ray background". Such a background
would be expected from the interaction of cosmic rays (very energetic charged particles
in space) with gas found between the stars.
Significant gamma-ray emission from our galaxy was first detected in 1967 by the
gamma-ray detector aboard the OSO-3 satellite. It detected 621 events attributable to
cosmic gamma-rays. However, the field of gamma-ray astronomy took great leaps
forward with the SAS-2 (1972) and the COS-B (1975-1982) satellites. These two
satellites provided an exciting view into the high-energy universe (sometimes called the
'violent' universe, because the kinds of events in space that produce gamma-rays tend to
be explosions, high-speed collisions, and such). They confirmed the earlier findings of
the gamma-ray background, produced the first detailed map of the sky at gamma-ray
wavelengths, and detected a number of point sources. However, the poor resolution of the
instruments made it impossible to identify most of these point sources with individual
stars or stellar systems.
66
Perhaps the most spectacular discovery in gamma-ray astronomy came in the late 1960s
and early 1970s from a constellation of defense satellites which were put into orbit for a
completely different reason. Detectors on board the Vela satellite series, designed to
detect flashes of gamma-rays from nuclear bomb blasts, began to record bursts of
gamma-rays -- not from the vicinity of the Earth, but from deep space! Today, these
gamma-ray bursts are seen to last for fractions of a second to minutes, popping off like
cosmic flashbulbs from unexpected directions, flickering, and then fading after briefly
dominating the gamma-ray sky. Studied for over 25 years now with instruments on board
a variety of satellites and space probes, including Soviet Venera spacecraft and the
Pioneer Venus Orbiter, the sources of these enigmatic high-energy flashes remain a
mystery. They appear to come from far away in the Universe, and currently the most
likely theory seems to be that at least some of them come from so-called hyper nova
explosions - supernovas creating black holes rather than neutron stars.
Gamma-ray astronomy is still mostly dominated by the quality of data. More and better
data from newer missions and better instruments is therefore essential for progress in the
field.
In astronomy, Gamma-ray bursters (GRBs) are flashes of gamma rays that last
from seconds to hours, the longer ones being followed by several days of X-ray after
glow. They occur at random positions in the sky several times each day. As of summer
2003, one of the more promising but still highly speculative ideas is that with the creation
of a black hole from a dying star. The black hole, surrounded by a rotating disk of matter
falling into it somehow emits energetic beam parallel to the axis of rotation. However, the
astrophysical community is still some distance away from coming to a consensus on the
mechanism for GRB's, although most are optimistic that the puzzle will be solved by
2010.
67
Cosmic gamma-ray bursts were discovered in the late 1960s by the US "Vela" nuclear
test detection satellites. The Velas were launched to detect radiation emitted by weapons
tests, but they picked up occasional bursts of gamma rays from unknown sources. While
the sensors on the Vela satellites had low angular resolution, in 1973 researchers at the
US Los Alamos National Laboratory in New Mexico were able to use the data from the
satellites to determine that the bursts came from deep space.
Gamma ray bursts can only be observed directly from space, as the atmosphere blocks
gamma rays. Astronomers believed that once better gamma-ray detectors were put in
orbit, they would be able to quickly pin down the locations of the GRB’s. After all, that is
what happened with X-ray sources. However, when such improved detectors were sent
into space in the 1970s, optical searches of the regions where the bursts originated
showed nothing of interest. The sensors were not accurate enough to pinpoint the location
of the bursts for detailed study.
Further information on the burst sources proved hard to obtain, and led to more questions
than answers. The first question posed by the GRB’s was: are they local to our own
Galaxy, or do they occur in the distant reaches of the Universe? The second question was:
what mechanism causes the bursts? If they do occur in the distant Universe, the
mechanism must be producing enormous amounts of energy.
Little progress was made on the matter through the 1980s, but in April 1991, the US
National Aeronautics and Space Administration (NASA) launched the "Compton Gamma
Ray Observatory" on board the space shuttle. One of the instruments on board Compton
was the "Burst & Transient Source Experiment (BATSE)", which could detect gamma-
ray bursts and locate their positions in the sky with reasonable accuracy. BATSE
established that there were at least two categories of gamma ray bursters: hard gamma ray
bursters and soft gamma ray repeaters.
Within a year, BATSE determined that GRB’s occur twice or three times a day, and are
randomly distributed over the entire sky. If they were events occurring in our own
Galaxy, they would be preferentially distributed in the plane of the Milky Way. Even if
they were associated with the galactic halo, they would still be preferentially distributed
towards the galactic center, 30,000 light years away, unless the halo were truly enormous.
Besides, if that were the case, nearby galaxies would be expected to have similar haloes,
but they did not show up as "hot spots" of faint gamma-ray bursts.
To many astronomers, this implied that the GRB’s originated in the distant Universe, but
that led to the problem of finding a mechanism that could generate so much energy. Other
theorists were also still able to come up with "local" models for the GRB’s, and BATSE
couldn't resolve the issue.
Uses
The powerful nature of gamma-rays has made them useful in the sterilizing of medical
equipment by killing bacteria. They are also used to kill bacteria in foodstuffs to
68
keep them fresher for longer. In spite of their cancer-causing properties, gamma rays
are also used to treat some types of cancer. Multiple concentrated beams of gamma
rays are directed on the growth in order to kill the cancerous cells. The beams are
aimed from different angles to focus the radiation on the growth while minimizing
damage to the surrounding tissues.
69
Methodology
First prepare a solution of Cs-Ba by using the mini generator. fill your syringe with
eluting solution. Remove the stoppers on either end of the mini-generator column.
Hold the mini-generator carefully above the glass vial with the arrows on the mini-
generator pointing downward. While your partner holds the glass vial, insert the syringe
firmly into the hole on the top of the generator without pushing on the syringe plunger.
While carefully holding the mini-generator and the vial, use the syringe to force about 10
drops (1 mL) of solution into the mini-generator. DO NOT SUCK UP ON THE
SYRINGE; ONLY INSERT SOLUTION IN THE DIRECTION OF THE ARROWS ON
THE MINI-GENERATOR. This will release the barium 137m into the glass vial. Once
you’ve pushed the solution through, remove the syringe and place it and the mini-
generator carefully back on the table.
Place the sensor window of the Geiger counter directly next to the glass vial and you will
hear an increase in the level of radiation, this is the radioactive decay of barium 137m
into barium 137.
Place the source container directly under the G-M counter. The distance source
(collimator) outlet-counter should be about 10cm.Remove the container lid.
Set the HV supply switch at zero volts. Branch all the segments of the set-upon .Start
The scalar. Slowly increase the high voltage (do not over come 1400V!), until you
Observe the scalar to start counting the pulses. Lower the high voltage and find the
Starting point (corresponding voltage) once again.
70
Perform about 10 measurements of the radiation intensity, beginning with the starting
Voltage and increasing each time the operating voltage for 20V. The measurement time
Should be of the order of 30 seconds. If the registered intensity increases sharply for a
Subsequent measurement do not continue.
Set the operating voltage about 100V above the starting point. Carry out the measurement
of the back ground, i.e. the intensity of radiation with the source well shut and
Placed at 1meter distance from the counter (at least).This measurement should be done
With the measuring time of the order of 500 seconds.
Bring the source back and place it under the counter. Open the lid. Carry out the
Absorption measurements for at least two sets of plates out of three available (Pb, Al, and
Cu).The measurements should be carried out with the measuring time selected in such
A manner that the total count is not lower than 1000.Start with measurement with out
Any absorbing plate and carry on placing on the source container subsequent plates. The
Thickness of each plate should be measured with the help of micrometric screw. The
Results should be gathered in the table.
Repeat this at least 15 times and record all of your data on your table for a total of at least
15 data points.
Turn the Geiger counter off. Replace the stoppers on the two ends of the mini-generator
and return any remaining eluting solution from your syringe into the bottle from which
you removed it. Pour the contents of your glass vial into the HCl waste bottles, replace
the cover on the glass vial and leave it with the “dirty vials.”
71
72
Observations and Calculations
73
We know that linear absorption coefficient is
µ = .693/HVT
Where HVT is the half value thickness and is
HVT = x-x/2
In this equation x is the time of any activity and x/2 is its half.
Now when activity is81 then x = 1min and when activity becomes then x/2 = 3min, and
HVT = 1-3 = -2min
Thus linear absorption coefficient is,
µ = .693/2 = .347
We also know that the mass absorption coefficient is
µm = µ/ total density
From the table total density = 49g/cm2
Thus
µm = .347/49 = .007
Now max energy
Max E = µ (measured)/µ (standard)
We know that,
µ (standard) = .7068
Thus,
Max E = .347/.7068 = 0.4905 = 0.5Mev
Since Max E for Cs, Ba-137 in case of gamma decay is .66Mev
Thus
% error = (0.66-0.5)x100/0.66 =24.2%
• Safety goggles and gloves must be worn at all times when working with the
radioisotope generators.
74
• You must wear closed-toe shoes; no sandals may be worn.
• The eluting solution contains a weak concentration of HCl, this can cause burns
on your skin and clothing, please be careful to not spill it and wear gloves and
goggles at all times.
• Please do not touch the sensor window face plate on the Geiger counter; this can
ruin this expensive piece of equipment.
• Dispose of your used gloves in the trash and wash your hands thoroughly before
leaving the lab.
• Do not gather near the G.M counter otherwise it will not give you correct
readings.
• Quickly take the readings because it Ba-137m have a very short life.
Be careful with the radiations because Gamma radiations are very dangerous.
Gamma-rays have the smallest wavelengths and the most energy of any other wave in the
electromagnetic spectrum. These waves are generated by radioactive atoms and in
nuclear explosions. Gamma-rays can kill living cells, a fact which medicine uses to its
advantage, using gamma-rays to kill cancerous cells.
75
Gamma-rays travel to us across vast distances of the universe, only to be absorbed by the
Earth's atmosphere. Different wavelengths of light penetrate the Earth's atmosphere to
different depths. Instruments aboard high-altitude balloons and satellites like the
Compton Observatory provide our only view of the gamma-ray sky.
Gamma-rays are the most energetic form of light and are produced by the hottest regions
of the universe. They are also produced by such violent events as supernova explosions
or the destruction of atoms, and by less dramatic events, such as the decay of radioactive
material in space. Things like supernova explosions (the way massive stars die), neutron
stars and pulsars, and black holes are all sources of celestial gamma-rays.
Gamma-ray astronomy did not develop until it was possible to get our detectors above all
or most of the atmosphere, using balloons or spacecraft. The first gamma-ray telescope,
carried into orbit on the Explorer XI satellite in 1961, picked up fewer than 100 cosmic
gamma-ray photons!
Unlike optical light and X-rays, gamma rays cannot be captured and reflected in mirrors.
The high-energy photons would pass right through such a device. Gamma-ray telescopes
use a process called Compton scattering, where a gamma-ray strikes an electron and loses
energy, similar to a cue ball striking an eight ball.
76
Who discovered gamma radiation?
Physicists credit French physicist Henri Becquerel with discovering gamma radiation. In
1896, he discovered that uranium minerals could expose a photographic plate through a
heavy opaque paper. Roentgen had recently discovered x-rays, and Becquerel reasoned
that uranium emitted some invisible light similar to x-rays. He called it "metallic
phosphorescence."
In reality, Becquerel had found gamma radiation being emitted by radium-226. Radium-
226 is part of the uranium decay chain and commonly occurs with uranium.
Gamma radiation is very high-energy ionizing radiation. Gamma photons have about
10,000 times as much energy as the photons in the visible range of the electromagnetic
spectrum.
Gamma photons have no mass and no electrical charge--they are pure electromagnetic
energy.
Because of their high energy, gamma photons travel at the speed of light and can cover
hundreds to thousands of meters in air before spending their energy. They can pass
through many kinds of materials, including human tissue. Very dense materials, such as
lead, are commonly used as shielding to slow or stop gamma photons.
Their wave lengths are so short that they must be measured in nanometers, billionths of a
meter. They range from 3/100ths to 3/1,000ths of a nanometer.
Gamma rays and x-rays, like visible, infrared, and ultraviolet light, are part of the
electromagnetic spectrum. While gamma rays and x-rays pose the same kind of hazard,
they differ in their origin. Gamma rays originate in the nucleus. X-rays originate in the
electron fields surrounding the nucleus or are machine-produced.
Gamma radiation emission occurs when the nucleus of a radioactive atom has too much
energy. It often follows the emission of a beta particle.
77
atom to barium-137. The nucleus ejects the beta particle. However, the nucleus still has
too much energy and ejects a gamma photon (gamma radiation) to become more stable.
Gamma emitting radio nuclides are the most widely used radiation sources. The
penetrating power of gamma photons has many applications. However, while gamma
rays penetrate many materials, they do not make them radioactive. The three radio
nuclides by far most useful are cobalt-60, cesium-137, and technetium-99m.
Uses of Cesium-137:
• cancer treatment
• measure and control the flow of liquids in numerous industrial processes
• investigate subterranean strata in oil wells
• measure soil density at construction sites
• ensure the proper fill level for packages of food, drugs and other products.
Uses of Cobalt-60:
Uses of Technetium-99m:
TC-99m is the most widely used radioactive isotope for diagnostic studies. (Technetium-
99m is a shorter half-life precursor of technetium-99.) Different chemical forms are used
for brain, bone, liver, spleen and kidney imaging and also for blood flow studies.
Another process, industrial radiography, uses gamma radiation to inspect metal parts and
welds for defects. A sealed radiation source, usually iridium-192 or cobalt-60, beams
gamma radiation at the part. Any gamma radiation passing through a crack or incomplete
weld exposes special photographic, or radiographic, film. (The process is similar to
taking an x-ray of a broken arm.) For example, manufacturers use radiography to inspect
jet engine turbine blades.
78
Gamma rays travel at the speed of light and exist only as long as they have energy. Once
their energy is spent, whether in air or in solid materials, they cease to exist. The same is
true for x-rays.
Most exposure to gamma and x-rays is direct external exposure. Gamma and x-rays can
easily travel great distances through air and penetrate several centimeters in tissue. Most
have enough energy to pass through the body, exposing all organs. X-ray exposure of the
public is almost always in the controlled environment of dental and medical procedures.
Although they are generally classified as an external hazard; gamma emitting radio
nuclides can also be inhaled, or ingested with water or food, and cause exposures to
organs inside the body. Depending on the radionuclide, they may be retained in tissue, or
cleared via the urine or feces.
Both direct (external) and internal exposure to gamma rays or X-rays are of concern.
Gamma rays can travel much farther than alpha or beta particles and have enough energy
to pass entirely through the body, potentially exposing all organs. A large portion of
gamma radiation largely passes through the body without interacting with tissue--the
body is mostly empty space at the atomic level and gamma rays are vanishingly small in
size. X-rays behave in a similar way, but have slightly lower energy. By contrast, alpha
and beta particles inside the body lose all their energy by colliding with tissue and
causing damage.
Gamma rays can ionize atoms in tissue directly or cause what are known as "secondary
ionizations." Ionizations are caused when energy is transferred from gamma rays to
atomic particles such as electrons (which are essentially the same as beta particles). These
energized particles then interact with tissue to form ions through secondary ionizations.
Because gamma rays are photons and thus interact less frequently with matter than alpha
and beta particles, they are more penetrating and the damage they cause can occur much
farther into tissue (that is, farther from the source of radiation).
Because of the gamma ray's penetrating power and ability to travel great distances, it is
considered the primary hazard to the general population during most radiological
79
emergencies. In fact, when the term "radiation sickness" is used to describe the effects of
large exposures in short time periods, the most severe damage almost certainly results
from gamma radiation.
You need specialized equipment to detect gamma radiation. You cannot see, or feel
radiation hitting your body. However, you should be familiar with radiation warning
symbols. You can protect yourself by avoiding devices with this symbol, and not entering
areas where the symbol is posted.
Your exposure to x-rays is almost entirely from dental and medical x-rays, including
mammograms. The best way to protect yourself from excessive radiation from x-rays is
to make sure the technician performing the procedure has the proper qualifications, and to
simply ask questions. You might inquire about the necessity of having an x-ray, or
receive assurance the x-ray machine has been inspected recently and that it is properly
calibrated. You should be aware of steps taken to prevent exposures to other parts of your
body (for example, through the use of a lead apron).
It is possible that you or a member of your family may encounter an industrial instrument
or device containing a gamma radiation source. Every year, hundreds of devices
containing radiation sources are lost, stolen, or otherwise enter the general public by
mistake. For example:
• A factory that has gone out of business may contain one or more such devices. As
the building structure is being dismantled, these forgotten devices often are
considered as scrap metal, or someone may think they have value and try to sell
them.
These devices should be avoided. You may recognize them by the radiation symbol,
which means the device is radioactive. You should also look for identifying information
such as "Nuclear Regulatory Commission" or the name of a radionuclide. Sometimes the
radioactive markings may be covered over and not visible.
If you find a device you think may be radioactive, stay away from it, and promptly call
your state radiation control program.
80
Verification of Inverse Square Law.
Aims
The aim of this experiment is to study the dependence of intensity of radiation on the
distance from its source.
Objective
The objective of this experiment is to verify Inverse Squarer Law.
Equipment
G.M counter, Cesium Barium generator, solution of HCl, Stopwatch, Timer Scalar.
81
Over View
In the previous investigation we looked at the statistical interpretation of radioactive
decay. When the decay particles are emitted they have equal probability of decaying in
any direction. If we have a detector of constant area, we will detect more particles the
closer we are to the source. As we move further away, we will count fewer, because we
are subtending a smaller solid angle of the source. We believe there should, therefore, be
1
a 2 dependence of the count rate as we move further away from the source with a
r
detector of constant area.
Methodology
1
To verify the dependence of the radiation intensity, you vary the distance between
r2
the source and detector by moving the lens holder (holding the source) along the optical
bench. You will not need any additional material for this investigation.
1. The radioactive source should still be mounted on the lens holder. Vary the distance r
between source and counter in 5 cm steps from 5 to 40 cm and measure the counting rate
As a function of distance. If you are not able to get as close as 5 cm, do the best you can.
The distance should be measured to the entrance window of the GM tube, which is
Recessed inside the cylindrical tube. PLEASE REMEMBER TO NEVER TOUCH THIS
ENTRANCE Slide the rubber o-ring that is around the WINDOW! Outside of the GM
tube cylinder to the approximate position of the entrance window. You will just have to
Approximate this, the best you can. Then make your measurements to the middle of the
o-ring.
82
2. Choose a time interval (try 100 s) such that your number of counts is about 10000 at
the 5 cm separation. Use this time interval for the rest of this part of the experiment.
3. Put your data results in Table 2-1 and in the appropriate column of the Excel file
L13.A2-1. DistanceDependence.xls
4. Now remove the Cs far away from the GM tube and take a background measurement
for 250 s.
83
Conclusion
84
The intensity (illuminance or irradiance ) of light or other linear waves radiating from a
point source (energy per unit of area perpendicular to the source) is inversely
proportional to the square of the distance from the source; so an object (of the same size)
twice as far away, receives only ¼ the energy (in the same time period).
More generally, the irradiance , i.e., the intensity (or power per unit area in the direction
of propagation ), of a spherical wave front varies inversely with the square of the distance
from the source (assuming there are no losses caused by absorption or scattering).
For example, the intensity of radiation from the sun is 9140 watts per square meter at the
distance of Mercury (0.387AU); but only 1370 watts per square meter at the distance of
earth (1AU)—a threefold increase in distance results in a ninefold decrease in intensity of
radiation.
Photographers and theatrical lighting professionals use the inverse-square law to
determine optimal location of the light source for proper illumination of the subject.
The fractional reduction in electromagnetic fluence (F) for indirectly ionizing radiation
with increasing distance from a point source can be calculated using the inverse-square
law. Since emissions from a point source have radial directions, they intercept at a
perpendicular incidence. The area of such a shell is 4pr2 where r is the radial distance
from the center.
The law is particularly important in diagnostic radiography and radiotherapy treatment
planning, though this proportionality does not hold in practical situations unless source
dimensions are much smaller than the distance r.
Examples
Let the total power radiated from a point source, e.g., an omni directional isotropic
antenna , be . At large distances from the source (compared to the size of the source), this
power is distributed over larger and larger spherical surfaces as the distance from the
source increases. Since the surface area of a sphere of radius is , then intensity of
radiation at distance is the energy or intensity decreases by a factor of ¼ as the distance is
doubled, or measured in dB it would decrease by 6.02 dB. This is the fundamental reason
why intensity of radiation , whether it is electromagnetic or acoustic radiation, follows
the inverse-square behaviour, at least in the ideal 3 dimensional context (propagation in 2
dimensions would follow a just an inverse-proportional distance behaviour and
propagation in one dimension, the plane wave , remains constant in amplitude even as
distance from the source changes).
Questions and Answers
85
What is the general equation of inverse square law?
Some physical effect is reduced in proportion to the square of the distance from it's
source. It applies to most forces or energies that radiate from a single point, like a
light bulb. If you move twice as far from the light source, you will receive only a
quarter as much light. And if you move three times as far from the bulb, you will
receive only 1/9 as much. 1/4 is the inverse of 22 and 1/9 is the inverse of 32.
If you are using the acoustics it is different, because the sound pressure is inversely
proportional to the distance (1/r) from the source. That is the inverse distance law.
It is because the radiation spreads out over a surface area as it moves away from the
source, and that surface area increases as R^2.
Nuclear Medicine is the medical specialty that uses very small amounts of radioactive
material to diagnose and treat disease. These materials, or tracers, are substances that are
attracted to specific organs or tissues by the nature of their chemical makeup. The tracer
emit energy, in the form of radiation, that is detectable by highly specialized equipment
known as gamma cameras or scintillation cameras. The information (in the form of
energy) is collected by the camera system and is transformed into images, which provide
anatomical and functional detail of the body part being imaged.
What are the radiation hazards associated with the Nuclear Medicine patient?
Nuclear Medicine procedures are very safe. A patient only receives an extremely small
amount of tracer, just enough to provide sufficient diagnostic information. The patient
dose, in many cases, is equal to or less than common X-ray procedures. Most tracers pass
quickly from the body through normal bodily functions. Patients should be encouraged to
drink additional fluids as this will aid in eliminating the tracer more quickly.
Are there special precautions for pregnant staff when handling patients who have
had a Nuclear Medicine procedure?
For most diagnostic procedures there would be no need for pregnant staff to take any
additional precautions other than limiting their direct contact to as short as necessary.
Radiation exposure follows the inverse square law which makes it dependant on both
time and distance from the source. The inverse square law states that if you double your
distance from the source your exposure rate drops by a factor of four, or if you triple your
distance, your exposure drops by a factor of nine. This, combined with the fact that most
diagnostic procedures use very small doses, means that the risk to hospital staff is very
small. Any patients receiving a therapeutic Nuclear Medicine procedure should be
86
handled by you after consultation with the Radiation Safety Officer and in accordance
with the policies of the respective institutions.
Yes, Nuclear Medicine procedures are commonly performed on children and are
generally used to evaluate bone pain, injuries, kidney or bladder conditions or infections.
The dose for the patient is adjusted according to the child's age and weight. Sedation is
sometimes required depending on the test being performed and the child.
Why are there delays between Nuclear Medicine procedures and not between X-ray
or Ultrasound procedures?
Nuclear Medicine procedures often use the same radioactive tracer combined with
different chemical elements to visualize different organ or tissue systems. As these
products break down and are eliminated from the body they would interfere with the
imaging of another organ system as they would no longer be found only in the target
organ or tissue. The Nuclear Medicine camera systems would not be able to differentiate
the target organ or system from that of a previous test. For the most common tracer of
Technetium it generally takes up to 48 hours to clear the body before another test can be
ordered. Isotopes such as Gallium and Iodine can take considerably longer.
There is no dose below which radiation induced injury is absent. Every X-ray exposure
involves risk. The benefits of radiation exposure should outweigh the risks, therefore,
occupational exposure should be at its absolute minimum.
What kind of protective devices are available to me if I must be near an area where
X-ray exposures are taken?
A lead apron is worn that covers 80% of your bone marrow. A thyroid shield is often
used to protect the thyroid gland. Lead gloves protect your hands if you are supporting or
assisting a patient who is having an X-ray and your hands are in close proximity to the X-
ray beam. However, radiation effects to the skin and extremities are non-existent at
today's dose levels.
How many portable chest X-rays can be taken in our area in one month?
The intensity of radiation one (1) metre from the portable is so small that a radiation
worker would have to be exposed to 2000 films a month to reach the dosage allowed the
general public.
Where is the best place to stand during an X-ray if you are assisting?
87
If you are holding or supporting a patient always stand off to the side so that the X-ray
beam is not pointing at you. No one should routinely hold or assist a patient during an X-
ray exam.
Why are the patient's gonads protected during a chest or foot X-ray?
This is a radiation safety precaution to protect the patient from scattered radiation. The
impact of radiation exposure on future generations has always been a concern. Radiation
can produce mutations through unrepaired structural breaks in chromosomes or through
changes in the order based on the DNA chain. If this occurs in germ cells it can be
transmitted to future generations. Female patients between the ages of 11 - 55 years are
questioned as to the possibility of pregnancy before irradiation. All patients are given
gonadal shielding routinely up until the age of 55 years.
What are the primary risks to the general public from medical radiation?
The primary risks are called stochastic effects. These effects include carcinogenic and
genetic effects. Ordering physicians consider the risks associated with an X-ray
procedure vs the benefits of a speedy diagnosis and treatment for the patient.
The largest source of unnecessary patient dose is unnecessary X-ray examinations. You
can minimize exposure through communication. For example: questioning the orders for
routine examinations. These should never be performed when there is no precise medical
indication. Routine chest X-rays for hospital admission or annual physicals or
asymptomatic patients are not necessary. Check to see if the patient has had X-rays done
through the emergency department before being admitted to your floor. Ask the patient if
recent films of the area of interest were performed at another site or clinic or under
another physician.
Occupational exposure can be reduced by the effective use of time, distance and
appropriate shielding. Take the following steps:
- reduce the amount of time spent in the area of the radiation source
- remain as far from the source as possible. The inverse square law states that if you
double your distance from the source your exposure rate drops by a factor of four, or if
you triple your distance your exposure drops by a factor of nine.
- utilize the use of fixed barriers or mobile shields as well as lead aprons and thyroid
collars.
88
To study Random Processes and fluctuations in Random processes
(Gaussian distribution Curve).
Aims
The aim of this experiment is to make students familiar with the Gaussian Distribution
Curve method i.e. how to handle the randomness.
Objective
The objective of this experiment is to understand the random nature of radioactivity.
Equipment
G.M Counter, Timer Scalar, Stop Watch, Radioactive Source.
Theory
G.M Tube
If a gamma - ray interacts with the GM tube (primarily with the wall by either the
Photoelectric Effect or Compton scattering) it will produce an energetic electron that may
pass through the interior of the tube.
89
Ionization along the path of the primary electron results in low energy electrons that will
be accelerated towards the center wire by the strong electric field. Collisions with the fill
gas produce excited states (~11.6eV) that decay with the emission of a UV photon and
electron-ion pairs (~26.4 eV for argon). The new electrons, plus the original, are
accelerated to produce a cascade of ionization called "gas multiplication" or a Townsend
avalanche. The multiplication factor for one avalanche is typically 106 to 108. Photons
emitted can either directly ionize gas molecules or strike the cathode wall, liberating
additional electrons that quickly produce additional avalanches at sites removed from the
original. Thus a dense sheath of ionization propagates along the central wire in both
directions, away from the region of initial excitation, producing what is termed a Geiger-
Mueller discharge.
90
The intense electric field near the anode collects the electrons to the anode and repels the
positive ions. Electron mobility is ~ 104 m/s or 104 times higher than that for positive
ions. Electrons are collected within a few µs, while the sheath of massive positive ions
(space charge) surrounding the center wire are accelerated much more slowly (ms)
outward towards the cathode.
The temporary presence of a positive space charge surrounding the central anode
terminates production of additional avalanches by reducing the field gradient near the
center wire below the avalanche threshold. If ions reach the cathode with sufficient
energy they can liberate new electrons, starting the process all over again, producing an
endless continuous discharge that would render the detector useless. An early method for
preventing this used external circuitry to "quench" the tube, but the introduction of
organic or halogen vapors is now preferred. The complex molecule of the quenching
vapor is selected to have a lower ionization potential ( < 10 eV) than that of the fill gas
(26.4 eV). Upon collision with a vapor molecule the fill gas ion gives up ~ 10 eV to the
quench vapor molecule which then quickly dissociates rather than losing its energy by
radioactive emission. The remainder of the partially neutralized vapor-atom energy (~ 4
eV) produces a UV photon that is strongly absorbed by the molecules and prevented from
reaching the cathode. Any quench vapor that might be accelerated and impact the cathode
dissociates on contact. Organic quench vapors, such as alcohols, are permanently altered
by this process, limiting tube life to ~ 109 counts. Halogen quench vapors dissociate in a
reversible manner later recombining for an essentially infinite life.
Dead Time
The sheath of positive ions (space charge) close to the anode reduces the intense
electric field sufficiently that approaching electrons do not gain sufficient energy to start
new avalanches. The detector is then inoperative (dead) for the time required for the ion
sheath to migrate outward far enough for the field gradient to recover above the
avalanche threshold. The time required for recovery to a value high enough for a new
pulse to be generated and counted is called the "dead time" and is of the order of 100 µs.
Measuring the dead time of a system requires two sources, S1 and S2. A counting
rate is measured first with S1, then S1 plus S2, and finally with only S2. If the dead time
were zero the counting rate with both sources together would be simply the sum of the
individual rates. The fact that it never is permits one to compute the actual dead time. At
modest count rates this is straightforward. If the counting rates are very high it is
necessary to decide which of two models applies, i.e., is the detector paralysable or non-
paralysable.
91
Oscilloscope:
The dead time of the GM tube may be directly determined with an oscilloscope by
observing the recovery envelope of the pulses. Note carefully where the CRO is
connected. The test point gives information about the GM tube only. Recovery must be
sufficient to produce a pulse large enough to exceed the "threshold" of the following
counting circuits. The "dead time" of these circuits should also be considered.
If n' counts are recorded in a time interval t with a detector of dead time d, it is
necessary to compute the true number n that would have been observed with a counter of
zero dead time. Since n'd is the total dead time, and n/t is the true counting rate, (n/t) n'd is
the total number of counts that would have occurred during the total dead time interval.
Therefore (n/t) n'd = n - n'. In terms of the counting rate, R = n/t and R' = n'/t,
The GM tube output is a charge pulse whose amplitude is independent of the energy
of the detected radiation. The only amplitude information that it can provide is that the
energy of the detected radiation was sufficient to produce electrons energetic enough to
penetrate to the sensitive region of the tube. The quantity of charge produced is directly
proportional to the "over voltage", i.e., the difference between the GM threshold voltage
at which a GM discharge will first occur, and the higher normal operating voltage. The
output signal will be directly proportional to the charge (108 - 1010 ion-pairs), and
inversely proportional to the circuit capacitance (GM tube capacitance + the connecting
cable capacitance + the input capacitance of the electronic system). The normal signal is
of the order of volts.
Counting Statistics
The definitions for sample means, variances, and probability distribution with symbols
are
Sample Mean:
92
Sample Variance:
Gaussian distribution
Under the conditions that are thought to apply to all radioactive decays (i.e., all the
nuclei are identical, independent, and each has a definite and constant probability of
decay in a unit time interval), one can derive a distribution function P(x) that is the
probability of observing x counts in one observation period.
The distribution of the values x about the true average µ is called the Gaussian
distribution and has the form:
93
The Meaning of Sigma:
Use only "natural room background" radiation as a source with the GM tube in
its lead "house". Take 0.5 minute runs and plot them on a histogram until the shape of the
distribution emerges, or you have 20 runs. Counting at low rates for short time intervals
(x < 20) produces the characteristically skewed Gaussian distribution.. Now calculate x-
bar and s.
Methodology:
After setting the GM tube with timer scalar I put the radioactive source at the face
of detector tube of GM counter at a distance of 3cm.By providing the ac source I switch
on the apparatus and apply the threshold voltage to the timer scalar which is 420 volts.
Then turn on the switch of counts ad take 30 readings with an interval of one minute
without any break.
Tabulate these readings and found out the sample mean and sample variance of all
readings. After this I found the standard derivation of both sample mean and variance. By
taking class intervals I draw a curve of my data which shows the Gaussian distribution
curve and calculate % error in σ.
94
Observations and Calculations
Along x-axis one small box = 3.2 ,Along y-axis one small box = 0.2
95
Now finding standard deviation (S.D) from both graph and observations. Which is
following
=1/30(20051) =668.4
S.D=√668.4
=25.9=26
=1/30(22105) =736.83
s =√736.83=27.1=27
96
S.D from graph:
S.D = FWHD/1.8
=48/1.8=26.66
Where FWHD is full width half maximum, and it is always 70.7% of maximum
frequency.
= (27) (100)/668.4
=4.04
= (26.66) (100)/668.4
=3.989 = 4
Calculate sigma:
= 726+599/2
=663
For ±σ;
±σ = (19) (100)/30=63.33%
97
For ±2σ;
For ±3σ;
% Error:
% error in ±3σ = 0%
98
Source of errors and precautions:
• The distance between GM tube and the source can disturb the experiment so it
should be keep in mind that the this distance is always less than 6cm.
• Resetting the timer scalar during performing the experiment do not give correct
readings, so while perform the experiment do not reset the timer scalar.
• Use the bars tube on the platform with as large a separation between the source
and detector as permits the reasonable count rates.
• The voltages applied to the timer scalar should not less than the threshold
voltages.
99
Questions and Answers
Safe means free from danger or risk. Safer means more nearly free from risk
than something else. Safest means the most nearly free from risk than other things under
discussion. Even the safest car is not safe (risk-free). And even the smallest exposure to
ionizing radiation is not safe (risk-free), with respect to cancer and inherited afflictions.
In other words, there is no "threshold" dose-level below which all cancer-risk from
radiation disappears.
The amount of the danger or risk depends on the amount of radiation exposure.
The only risk-free (safe) dose is zero-dose, with respect to unrepairable injury of
chromosomes and DNA., by any reasonable standard of scientific proof. In 1993, the
United Nations Scientific Committee on Effects of Atomic Radiation supported the same
conclusion (UNSCEAR 1993). And in 1995, Britain's National Radiological Protection
Board also concluded that the weight of the evidence "falls decisively in favor of" the no-
threshold conclusion for benign and malignant tumors (NRPB 1995).
When an individual receives a small extra dose of radiation, the person receives
a small extra risk of cancer --- say, 1 chance in 1,000. The person has 999 chances out of
1,000 of escaping. But if 25,000,000 people like that individual each receive the same,
small extra dose of radiation, each person receives 1 chance in 1,000. The consequence is
a rate of 25,000 extra cancers in that group. Point: A small personal risk can mean a
large actual rate for a group --- a fact which produces important ethical and health issues.
We think that ionizing radiation is very probably the single most important
human carcinogen of the 20th century. In 1997, CNR will publish a study which is
consistent with that hypothesis.
100
Can one case of cancer have more than one cause?
Most experts currently accept (a) the single-cell origin of a cancer and (b) the
requirement for multiple genetic abnormalities in the same cell. It follows that a single
case of cancer very probably has more than one cause, even if carcinogens act additively
instead of synergistically.
When you estimate that 75% of recent and current breast-cancer in the USA is due
to earlier exposure to medical irradiation, do you mean that all other agents
combined are responsible for only 25% of the cases?
No, we don't. Our 75% incorporates a very big role for non-radiation agents,
because it explicitly incorporates the assumption of synergy between them and radiation,
with the other agents causing each unit of radiation to be much more potent in causing
breast cancer in the USA than in Japan
How can radiation both be a cause of cancer and also be used to treat cancer?
The "current wisdom" is that cancer begins with a single cell having abnormal
genetic instructions. Over time, it (or one of its descendant cells) acquires additional
injuries. Finally, a cell's abnormal instructions cause it to do abnormal things --- such as
dividing too often, or forming a tumor, or migrating from its appropriate location to live
and divide elsewhere in the body (metastasis). These cancerous activities are done by
living cells, whose abnormalities can be caused by radiation.
When radiation is used to treat cancer, it is used in very high doses which do
enough damage to kill cells. Dead cells cannot behave like cancer. It is very difficult to
give radiation only to cancer cells, without giving both high and low doses of radiation to
healthy cells in the neighborhood. Methods in radiation therapy are improving with time.
We hear from too many women with breast cancer whose own physicians told
them only about the benefits from radiation therapy --- but not about the side-effects
which sometimes occur on the irradiated side --- such as chronic swelling of the arm,
chronic pain in the arm, paralysis of the arm (from radiation damage to its nerve), broken
ribs (from radiation damage to bone), or radiation damage to the underlying lung or heart.
Unavoidably, the non-cancerous breast also receives considerable radiation exposure.
101
Patients who consider radiation therapy for abdominal cancers may also want to
ask for details about potential complications from radiation damage involving the
bladder, intestines, ureters, kidneys, nerves, spine, etc.
Aren't some people more sensitive to radiation than the average person?
Yes, almost certainly. But there is no way to identify them --- yet. For instance,
several different genes provide every cell with the ability to repair routine injuries to
chromosomes and DNA. People who are born with a faulty "repair gene" in every cell,
are going to be more vulnerable than the average person to cancer induced by radiation
and by other carcinogens (mutagens).
and other women will have lower risks than indicated above.
To a cell, all high-speed electrons feel alike, except for their particular energy
(Introduction). A cell does not know why such electrons are there. And a cell does not
care whether they come because of an external source (like an x-ray machine or a radium
dial) or because of a radioactive substance inside you (for example, cesium-137,
strontium-90, iodine-131). But the cell cares a lot about the number of such electrons,
because (at equal energy per electron) the damage is proportional to the number.
Radiation exposure, from natural cosmic sources, increases with altitude, with
peak dose at about 45,000 feet. Dose from cosmic radiation also varies with latitude; it
is lowest near the equator and highest near the poles. Therefore, the extra radiation dose
from flying depends on (a) the particular route, (b) the duration of the flight, and (c) the
fraction of the trip spent below the flight's maximum altitude.
102
Why do some sources say our average dose from natural background is 100 milli-
rems per year, and other sources say the dose is 250 milli-rems or more? Who's
right?
100 milli-rems per year refers to the average annual whole-body exposure. Every
organ is at risk, including the ovaries and testes. The figure of 100 milli-rems per year
excludes exposure by natural radon and thoron because these radio-nuclides and their
radioactive decay-products cause primarily lung-exposure, rather than primarily whole-
body exposure.
Rads, rems, grays, sieverts, effective dose equivalents, roentgens --- how can we cope
with such terms?
The rad is the most "solid" unit of biological dose, because it contains no
assumptions. A rad is defined as a certain amount of energy deposited by high-speed
particles per gram of biological tissue .Rads and roentgens are almost equivalent. The
gray is the name for 100 rads.
The rem is a unit which incorporates some evidence and some assumptions
about the relative harmfulness of various high-speed particles, even when they deliver the
same amount of energy per gram of biological tissue. In general, the rad and the rem are
equivalent only when discussing gamma rays (or certain xrays). The sievert is the name
for 100 rems.
103
extra milli-rad of gamma dose from our detector, we would have to sit 3 feet away from it
for about 80,000 hours.
Which is more dangerous --- a radioactive substance with a short half-life or a long
half-life?
Two opposite answers are possible! To understand why, one must consider the
very simple --- but amazing --- law of radioactive decay, which is: The fraction of atoms
(of a pure radio-nuclide) decaying per unit of time equals 0.693 divided by the
radioactive half-life. If the half-life is expressed in years, then the fraction decaying is
"per year."
The radioactive half-life of plutonium-239 is about 24,400 years, compared with about
88 years for plutonium-238. The way their atoms decay is comparable: Each atom ejects
(out of its nucleus) a high-speed alpha particle having over 5 million electron-volts of
energy. An alpha particle consists of 2 protons plus 2 neutrons; the particle carries a +2
electrical charge; it interacts so fiercely with tissue that it "spends" all of its kinetic
energy within just a few cells.
The fraction of Pu-239 atoms decaying per year = 0.693 / 24,400 years =
0.000028402. So, during the first year, the number of atoms decaying = 100,000 atoms
times 0.000028402 = 2.8 atoms. Since there are no fractional atoms, we'll say 3 atoms.
The fraction of Pu-238 atoms decaying per year = 0.693 / 88 years = 0.007875. So,
during the first year, the number of atoms decaying = 100,000 atoms times 0.007875 =
788 atoms --- lots more than 3.
During the second year, the decayed atoms are no longer available to decay. So
the number of Pu-239 atoms decaying = 99,997 available atoms x 0.000028402 = 2.84
atoms, or 3 again. The number of Pu-238 atoms decaying = 99,212 atoms x 0.007875 =
781 atoms --- still lots more than 3.
Since the biological damage per year is proportional to the number of decaying
atoms, the Pu-238 will remain much more dangerous, if you start with equal numbers of
atoms.
by contrast, the Pu-239 will do slightly more damage than the Pu-238, if you
start with equal curies --- or partial curies (e.g., a nano-curie: "only" 37 decays per
second).
Many more atoms of Pu-239 than Pu-238 are required to produce an equal
number of decays per second. Why? The fraction of Pu-238 atoms decaying per unit time
is about 277 times larger than the fraction of Pu-239 atoms decaying per unit time. An
example of equal decays from unequal number of atoms: (1,000,000 Pu-238 atoms) x
104
(0.007875) = 7,875 decays during first year. And: (277,000,000 Pu-239 atoms) x
(0.000028402) = 7,867 decays during first year --- the same.
Initially equal curies of Pu-239 and of Pu-238 cause equal decays (equal
damage) during the first year. But during every subsequent year, the remaining Pu-238
atoms eject fewer alpha particles per year than the remaining Pu-239 atoms. That is
because a smaller fraction remains of the original Pu-238 atoms than the original Pu-239
atoms. The ratio of remaining atoms is no longer 277. This being the case, the two
samples cannot continue to generate equal decays per year, as they did at the outset. Pu-
239 generates more than Pu-238.
105
Glossary of Nuclear Science
Terms
A|B|C|D|E|F|G|H|I|J|K|L|M|N|O|P|Q|R|S|T|U|V|W|X|Y|Z
-A-
Absorber
Any material that stops ionizing radiation. Lead, concrete, and steel attenuate
gamma rays. A thin sheet of paper or metal will stop or absorb alpha particles and
most beta particles.
Alpha particle (alpha radiation, alpha ray)
A positively charged particle (a Helium-4 nucleus) made up of two neutrons and
two protons. It is the least penetrating of the three common forms of radiation,
being stopped by a sheet of paper. It is not dangerous to living things unless the
alpha-emitting substance is inhaled or ingested or comes into contact with the lens
of the eye.
Atom
A particle of matter indivisible by chemical means. It is the fundamental building
block of elements.
Atomic number
The number assigned to each element on the basis of the number of protons found
in the element's nucleus.
Atomic weight (atomic mass)
Approximately the sum of the number of protons and neutrons found in the
nucleus of an atom.
-B-
Background radiation
The radiation of man's natural environment originating primarily from the
naturally radioactive elements of the earth and from the cosmic rays. The term
may also mean radiation extraneous to an experiment.
Beta particle (beta radiation, beta ray)
An electron of either positive charge (ß+) or negative charge (ß-), which has been
emitted by an atomic nucleus or neutron in the process of a transformation. Beta
particles are more penetrating than alpha particles but less than gamma rays or x-
rays.
-C-
106
Contamination
Radioactive material deposited or dispersed in materials or places where it is not
wanted.
Cow
A radioisotope generator system.
Curie (Ci)
The basic unit used to describe the intensity of radioactivity in a sample of
material. One curie equals thirty-seven billion disintegrations per second, or
approximately the radioactivity of one gram of radium.
-D-
Daughter
A nucleus formed by the radioactive decay of a different (parent) nuclide.
Decay (radioactive)
The change of one radioactive nuclide into a different nuclide by the spontaneous
emission of alpha, beta, or gamma rays, or by electron capture. The end product is
a less energetic, more stable nucleus. Each decay process has a definite half-life.
Decontamination
The removal of radioactive contaminants by cleaning and washing with
chemicals.
Density
That property of a substance which is expressed by the ratio of its mass to its
volume.
Dose
A general term denoting the quantity of radiation or energy absorbed in a specific
mass.
-E-
Electromagnetic radiation
Radiation consisting of electric and magnetic waves that travel at the speed of
light. Examples: light, radio waves, gamma rays, x-rays.
Electron
An elementary particle with a unit electrical charge and a mass 1/1837 that of the
proton. Electrons surround the atom's positively charged nucleus and determine
the atom's chemical properties.
Electron capture
A radioactive decay process in which an orbital electron is captured by and
merges with the nucleus. The mass number is unchanged, but the atomic number
is decreased by one.
Eluant
Washing solution (The solution that is introduced into the cow).
Eluate
The washings obtained by elution (the solution that comes out of the cow).
107
Elute
To separate by washing (to milk).
Excited state
The state of an atom or nucleus when it possesses more than its normal energy.
The excess energy is usually released eventually as a gamma ray.
-F-
Fission
The splitting of a heavy nucleus into two roughly equal parts (which are nuclei of
lighter elements), accompanied by the release of a relatively large amount of
energy in the form of kinetic energy of the two parts and in the form of emission
of neutrons and gamma rays.
Fission products
Nuclei formed by the fission of heavy elements. They are of medium atomic
weight and almost all are radioactive. Examples: strontium-90, cesium-137.
-G-
Gamma ray
A highly penetrating type of nuclear radiation, similar to x-radiation, except that it
comes from within the nucleus of an atom, and, in general, has a shorter
wavelength.
Geiger counter
A Geiger-Müller detector and measuring instrument. It contains a gas-filled tube
which discharges electrically when ionizing radiation passes through it and a
device that records the events.
Generator
A cow-a system containing a parent-daughter set of radioisotopes in which the
parent decays through a daughter to a stable isotope. The daughter is a different
element from that of the parent, and, hence, can be separated from the parent by
elution (milking).
-H-
Half-life
The time in which half the atoms of a particular radioactive nuclide disintegrate.
The half-life is a characteristic property of each radioactive isotope.
Health physics
That science devoted to recognition, evaluation, and control of all health hazards
from ionizing radiation.
-I-
108
Induced radioactivity
Radioactivity that is created by bombarding a substance with neutrons in a reactor
or with charged particles produced by particle accelerators.
Ion
An atomic particle that is electrically charged, either negative or positive.
Ionizing radiation
Radiation that is capable of producing ions either directly or indirectly.
Irradiate
To expose to some form of radiation.
Isomer
One of several nuclides with the same number of neutrons and protons capable of
existing for a measurable time in different nuclear energy states.
Isometric transition
A mode of radioactive decay where a nucleus goes from a higher to a lower
energy state. The mass number and the atomic number are unchanged.
Isotope
Isotopes of a given element have the same atomic number (same number of
protons in their nuclei) but different atomic weights (different number of neutrons
in their nuclei). Uranium-238 and uranium-235 are isotopes of uranium.
-K-
K-capture
The capture by an atom's nucleus of an orbital electron from the first K-shell
surrounding the nucleus.
keV
One thousand electron volts.
-L-
-M-
MeV
One million electron volts.
Microcurie (µCi)
One millionth of a curie (3.7 x 104 disintegrations per second).
Milk
To elute a cow.
Minigenerator
A trademark of Union Carbide Corporation that is used to identify radioisotope
generator systems for educational use.
-N-
109
Neutrino
An electrically neutral particle with negligible mass. It is produced in many
nuclear reactions such as in beta decay.
Neutron
One of the basic particles which make up an atom. A neutron and a proton have
about the same weight, but the neutron has no electrical charge.
Nuclear reactor
A device in which a fission chain reaction can be initiated, maintained, and
controlled. Its essential components are fissionable fuel, moderator, shielding,
control rods, and coolant.
Nucleon
A constituent of the nucleus; that is, a proton or a neutron.
Nucleonics
The science, technology, and application of nuclear energy.
Nucleus
The core of the atom, where most of its mass and all of its positive charge is
concentrated. Except for hydrogen, it consists of protons and neutrons.
Nuclide
Any species of atom that exists for a measurable length of time. A nuclide can be
distinguished by its atomic weight, atomic number, and energy state.
-O-
-P-
Parent
A radionuclide that decays to another nuclide which may be either radioactive or
stable.
Photon
A quantity of electromagnetic energy. Photons have momentum but no mass or
electrical charge.
Proton
One of the basic particles which makes up an atom. The proton is found in the
nucleus and has a positive electrical charge equivalent to the negative charge of
an electron and a mass similar to that of a neutron: a hydrogen nucleus.
-Q-
-R-
Rad
Radiation Absorbed Dose. The basic unit of an absorbed dose of ionizing
radiation. One rad is equal to the absorption of 100 ergs of radiation energy per
gram of matter.
Radioactive dating
110
A technique for estimating the age of an object by measuring the amounts of
various radioisotopes in it.
Radioactive waste
Materials which are radioactive and for which there is no further use.
Radioactivity
The spontaneous decay of disintegration of an unstable atomic nucleus
accompanied by the emission of radiation.
Radioisotope
A radioactive isotope. A common term for a radionuclide.
Radionuclide
A radioactive nuclide. An unstable isotope of an element that decays or
disintegrates spontaneously, emitting radiation.
Rate meter
An electronic instrument that indicates, on a meter, the number of radiation
induced pulses per minute from radiation detectors such as a Geiger-Muller tube.
-S-
Scaler
An electronic instrument for counting radiation induced pulses from radiation
detectors such as a Geiger-Muller tube.
Scintillation counter
An instrument that detects and measures gamma radiation by counting the light
flashes (scintillations) induced by the radiation.
Secular equilibrium
A state of parent-daughter equilibrium which is achieved when the half-life of the
parent is much longer than the half-life of the daughter. In this case, if the two are
not separated, the daughter will eventually be decaying at the same rate at which
it is being produced. At this point, both parent and daughter will decay at the
same rate until the parent is essentially exhausted.
Shielding
A protective barrier, usually a dense material, which reduces the passage of
radiation from radioactive materials to the surroundings.
Source
A radioactive material that produces radiation for experimental or industrial use.
Spill
The accidental release of radioactive materials.
Stable
Non-radioactive.
-T-
111
Tracer
A small amount of radioactive isotope introduced into a system in order to follow
the behavior of some component of that system.
Transmutation
The transformation of one element into another by a nuclear reaction.
- UVWXYZ -
112