FlexPro A3V A4V Logo
FlexPro A3V A4V Logo
FlexPro A3V A4V Logo
FLEX-PRO
Exclusive:
TF D system
Tube Failure Detection
ProSeries
TWO-YEAR
WARRANTY
ProSeries
TMR
by Blue-White Ind.
Page 2
Flex-Pro
TABLE OF CONTENTS
Section Heading
Page
1.0
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1
Available Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3
Materials of Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5
Agency Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.0
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1
Mounting Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2
Mounting Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installing Injection Fitting and Strainer . . . . . . . . . . . . . . . . . . . . 7
2.3
2.4
Input Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.5
Wiring Terminals and I/O Schematics . . . . . . . . . . . . . . . . . . . . 9
3.0
How to Operate Flex-Pro. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3.1
Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.2
Configuration Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.2.1 Language Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3.2.2 Display Rate (units of measure) . . . . . . . . . . . . . . . . . . . . . . . . 13
3.2.3 Reset Factory Defaults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.0
Input Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.1
Max RPM cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2
Max Flowrate (Output Calibration) . . . . . . . . . . . . . . . . . . . . . . 15
4.3
Input Setup (Operating Mode Configuration) . . . . . . . . . . . . . . . 16
4.3.1 Manual Adjust (manual speed adjust) . . . . . . . . . . . . . . . . . . . . 16
4.3.2 4 - 20 mA Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.3.3 0 - 10 VDC Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.3.4 Frequency Input (Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.3.5 Pulse Batch (low speed batch) . . . . . . . . . . . . . . . . . . . . . . . . . 20
4.3.6 Manual Cycle Adjust (repeating cycle timer). . . . . . . . . . . . . . . . 21
4.3.7 Dispensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
4.3.8 Manual Dosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4.3.9 Proportional Dosing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
4.4
Contact Closure Input (Remote start/stop) . . . . . . . . . . . . . . . . . 25
4.5
Set FVS (Flow Verification System). . . . . . . . . . . . . . . . . . . . . . 26
4.6
TFD (Tube Failure Detection) . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.6.1 TFD Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.7
Remote/Local Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.8
Pump Tube Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.0
Output Setup (Alarm Relays & Output Signal signals) . . . . . . 29
5.1
Signal Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6.0
Pump Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.1
Routine Inspection and Maintenance . . . . . . . . . . . . . . . . . . . . . 31
6.2
How to Clean and Lubricate the Pump . . . . . . . . . . . . . . . . . . . 31
6.3
Reverse Rotor Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
6.4
Tube Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.5
A3 Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6.6
A4 Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
7.0
Tubing Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.1
Tube Life Estimates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7.2
Output Versus Fluid Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . 38
1.0
Introduction
Congratulations on purchasing the Flex-Pro variable speed Peristaltic Metering Pump.
Your Flex-Pro pump is pre-configured for the tubing that shipped with your metering pump. The tubing assembly
has an Identification number printed for easy re-order.
Please Note: Your new pump has been pressure tested at the factory with clean water before shipping. You may
notice trace amounts of clean water in the pre-installed tube assembly. This is part of our stringent quality assurance program at Blue-White Industries.
Page 3
Flex-Pro
1.1
Available Models
Max
Speed
Feed Rate
Max
Pressure
Max
Temperature
A3 Model Numbers
LPH
.003 - 7.8
.026 - 66.0
.038 - 96.0
.050 - 126
ML/Min
.05 - 132
.4 - 1097
.6 - 1596
.8 - 2100
RPM
125
125
125
125
PSI (bar)
125 (8.6)
125 (8.6)
125 (8.6)
125 (8.6)
F (C)
185 (85)
185 (85)
185 (85)
185 (85)
115V AC
A3V24-*ND
A3V24-*NH
A3V24-*NJ
A3V24-*NK
230V AC
A3V25-*ND
A3V25-*NH
A3V25-*NJ
A3V25-*NK
220V AC
A3V26-*ND
A3V26-*NH
A3V26-*NJ
A3V26-*NK
LPH
.050 - 126
ML/Min
.8 - 2100
RPM
125
PSI (bar)
30 (2.1)
F (C)
185 (85)
115V AC
230V AC
220V AC
A3V24-*NKL A3V25-*NKL A3V26-*NKL
RPM
125
125
ML/Min
.4 - 920
.7 - 1800
PSI (bar)
50 (3.4)
50 (3.4)
F (C)
130 (54)
130 (54)
115V AC
A3V24-*TH
A3V24-*TK
230V AC
A3V25-*TH
A3V25-*TK
220V AC
A3V26-*TH
A3V26-*TK
F (C)
130 (54)
130 (54)
130 (54)
130 (54)
115V AC
A3V24-*GE
A3V24-*GG
A3V24-*GH
A3V24-*GK
230V AC
A3V25-*GE
A3V25-*GG
A3V25-*GH
A3V25-*GK
220V AC
A3V26-*GE
A3V26-*GG
A3V26-*GH
A3V26-*GK
ML/Min
.1 - 290
.3 - 637
.6 - 1570
.7 - 1800
RPM
125
125
125
125
Max
Speed
Feed Rate
PSI (bar)
65 (4.5)
65 (4.5)
65 (4.5)
65 (4.5)
Max
Max
Pressure Temperature
A4 Model Numbers
LPH
.04 - 108
.07 - 168
.08 - 192
.09 - 204
.15 - 378
.24 - 600
ML/Min
.7 - 1800
1.1 - 2800
1.3 - 3200
1.4 - 3400
2.5 - 6300
4.0 - 10000
RPM
125
125
125
125
125
125
PSI (bar)
125 (8.6)
100 (6.9)
80 (5.5)
100 (6.9)
50 (3.4)
30 (2.0)
F (C)
185 (85)
185 (85)
185 (85)
185 (85)
185 (85)
185 (85)
115V AC
A4V24-*NH
A4V24-*NJ
A4V24-*NK
A4V24-*NHH
A4V24-*NL
A4V24-*NP
220V AC
230V AC
A4V26-*NH
A4V25-*NH
A4V26-*NJ
A4V25-*NJ
A4V26-*NK
A4V25-*NK
A4V25-*NHH A4V26-*NHH
A4V26-*NL
A4V25-*NL
A4V26-*NP
A4V25-*NP
LPH
.07 - 192
.17 - 420
ML/Min
1.3 - 3200
2.8 - 7000
RPM
125
125
PSI (bar)
30 (2.1)
30 (2.1)
F (C)
185 (85)
185 (85)
115V AC
230V AC
220V AC
A4V24-*NKL A4V25-*NKL A4V26-*NKL
A4V24-*NKKL A4V25-*NKKL A4V26-*NKKL
F (C)
130 (54)
130 (54)
130 (54)
115V AC
A4V24-*TH
A4V24-*TK
A4V24-*THH
230V AC
A4V25-*TH
A4V25-*TK
A4V25-*THH
F (C)
130 (54)
130 (54)
130 (54)
115V AC
A4V24-*GH
A4V24-*GK
A4V24-*GKK
220V AC
230V AC
A4V26-*GH
A4V25-*GH
A4V26-*GK
A4V25-*GK
A4V25-*GKK A4V26-*GKK
LPH
.03 - 78
.06 - 162
.08 - 192
ML/Min
.5 - 1300
1.1 - 2700
1.3 - 3200
RPM
125
125
125
PSI (bar)
30 (2.1)
30 (2.1)
30 (2.1)
220V AC
A4V26-*TH
A4V26-*TK
A4V26-*THH
LPH
.06 - 150
.09 - 210
.20 - 378
ML/Min
1.0 - 2500
1.4 - 3500
2.5 - 6300
RPM
125
125
125
PSI (bar)
65 (4.5)
65 (4.5)
65 (4.5)
! The Flex-Pro Peristaltic Pumps motor speed is linear over the entire 0.05% to 100% adjustment
range.
! Output versus pressure is nearly linear in all models. Larger tubes exhibit greater losses.
! Output versus viscosity curves are shown at the end of this manual.
! For optimum tube life, specify the pump so that it operates at the lowest possible RPM and
pressure.
Page 4
1.2
Flex-Pro
Specifications
14 F to 115 F (-10 C to 46 C)
Maximum viscosity:
12,000 Centipoise
Display
Operating Voltage:
A3 MODELS: 96 to 264VAC-50/60Hz, 220W
A4 MODELS: 96 to 264VAC-50/60Hz, 350W
Display Languages
English, Spanish, French or German selectable.
Keypad
Ten button positive action tactile switch keypad.
Security
Programmable 4-digit password.
Enclosure:
NEMA 4X (IP66), Polyester powder coated aluminum.
Maximum Overall Dimensions:
A3 models: 8-1/8W x 10-3/4H x 15-1/4D (20.6W x 27.3H x 38.9D cm)
A4 models: 12-1/8W x 14-1/4H x 18-5/8D (30.8W x 36.1H x 47.3D cm)
1.3
Materials of construction
Wetted components:
Pump Tube Assembly (Model Specific - 2 provided):
Non-Wetted components:
Enclosure:
413 Aluminum (Polyester powder coated)
Pump Head:
Injection / Back-flow Check valve:
Body & insert: . . . . . .
Check Ball: . . . . . . . .
Spring: . . . . . . . . . .
Ball Seat O-ring: . . . . .
Static Seal O-ring: . . . .
Duckbill anti-scale valve:
PVDF
Ceramic
Hastelloy C-276
Vitonq (optional EP)
Vitonq (optional EP)
Santopreneq
Cover Screws:
Stainless Steel
Roller Assembly:
Motor Shaft:
Chrome plated steel
Power Cord:
3 conductor, SJTW-A Water-resistant
Page 5
Flex-Pro
1.4
Features
!
Peristaltic pump design does not have valves that can clog requiring maintenance.
Self priming - even against maximum line pressure. By-pass valves are not required. Cannot vapor lock or
lose prime. Syphoning cannot occur.
Output rates to: 158.5 GPH (600 LPH) and pressures to 125 PSI (8.6 Bar).
Patented Tube Failure Detection (TFD) system. Senses tube failure by detecting chemical in the pump head.
No false triggering.
SCADA Inputs include: 4-20mA, 0-10Vdc, and Pulse inputs for remote external speed control and 0-30 VDC /
contact closure remote start/stop.
VGA Graphic multi-color backlit LCD displays remote/local control status, motor speed, output rate, input
signal values, service and alarm status.
Outputs include: Scalable 4-20mA or pulse, one 250V/6A relay and three 115V/1A contact closures assignable
to monitor up to 17 different pump functions including TFD, FVS, remote/local control setting, motor on, fault,
current operating mode, and others.
Two CNC precision machined squeeze rollers and two alignment rollers for optimum squeeze, unparalleled
accuracy, and tube life.
Heavy duty rotor - single piece plastic rotor means no flexing and increased accuracy (no metal springs or
hinges to corrode).
Enclosure Rating:
NEMA 4X: Constructed for either indoor or outdoor use to provide a degree of protection to personnel against
incidental contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation of ice
on enclosure.
IP66: No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure from
any direction shall have no harmful effects.
1.5
Agency Listings
This pump is ETL listed to conforms to the following:
UL Standard 778 as a motor operated water pump
CSA Standard C22.2 as process control equipment
This pump complies to the Machinery Directive 98/37/EC, BS EN 60204-1, Low Voltage Directive
73/23/EC BS EN 61010-1, EMC Directive 89/336/EC, BS EN 50081-1/BS EN 50082-1.
Symbol
Explanation
WARNING, risk of electric shock
Page 6
2.0
Flex-Pro
Installation
Risk of chemical overdose. Be certain pump does not overdose chemical during
CAUTION
backwash and periods of no flow in circulation system.
!
CAUTION
!
CAUTION
!
2.1
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
All diagrams are strictly for guideline purposes only. Always consult an expert before
installing metering pump on specialized systems. Metering pump should be serviced by
qualified persons only.
Mounting Location
Choose an area located near chemical supply tank, chemical injection point, and electrical supply. Install pump
where it can be easily serviced.
! 316SS Mounting brackets are included. Mount pump to a secure surface using enclosed mounting hardware.
! Mount pump close to injection point. Keep inlet (suction) and outlet (discharge) tubing as short as possible.
! A back flow prevention check valve is recommended at the discharge of the pump to prevent system fluid from
flowing back through the pump during tube replacement or if the tube should rupture.
! A pressure relief valve is recommended at the discharge of the pump to prevent premature wear and damage to
the pump tube in the event the discharge line becomes blocked.
! The Flex-Pro does not require back pressure. Pressure regulator valves are not required. Keep the discharge
2.2 Dimensions
18.63
(47.3cm)
12.13"
30.8cm)
14.2"
(36.1cm)
6.0"
(15.2cm)
Dim
A
B
C
D
E
F
A3 Series
cm
Inches
27.3
10-3/4
20.6
8-1/8
38.9
15-1/4
25.4
10
12-1/4
31.0
4-1/4
10.7
A4 Series
cm
Inches
36.1
14-1/4
30.8
12-1/8
47.3
18-5/8
27.9
11
13-5/8
34.6
6
15.2
11.0"
(27.9cm)
13.63
(34.6cm)
A4 Series
11.50 (29.2 cm)
Maximum bolt hole size
0.200 diameter (4 places)
OptionalExtended Brackets
Model Number 72000-380
Stainless Steel extended brackets allow pump to be securely mounted to most any surface;
floor, shelf, or skid. Brackets lift pump up 4-1/2 inches (11.43 cm), for easy pump access in
hard to reach areas.
n Raise metering pump 4-1/2 inches (11.43 cm) off ground or a surface.
n Made out of tough Stainless Steel.
n Provides a stable mounting surface.
Model #
72000-380
A3 Series
8.25 (20.9 cm)
Description
Extended Mounting Bracket, 1 Pair, SS, 4 SS Screws
Page 7
Flex-Pro
2.3 Installing Discharge Injection Fitting and Suction Strainer
! CAUTION
Proper eye and skin protection must be worn when installing and servicing pump.
! CAUTION
This Pump Has Been Evaluated for Use with Water Only.
Pipe
Tee
Suction Strainer
Install
upward
for best
results
Male NPT
PVDF
Male NPT
or Hose Barb
PVDF
Suction
Strainer
Hastelloy C-276
Ceramic
Discharge
Pipe or
Tubing
(not included)
Male NPT
or Hose Barb
Removable
275 Micron
Filter
PVDF
Polypropylene
Pipe tee
PVC Suction Tubing
3/8" OD x 1/4 ID
PVDF
Injection
Check valve
Tube retaining
nut
Discharge
Tubing
PVDF
Hastelloy C-276
Ceramic
T/FEP (optional EP)
PVDF
Ceramic
Weight
Polypropylene
Strainer
Page 8
Flex-Pro
2.4
Input Power Connections
WARNING
Risk of electric shock cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
WARNING
Electrical connections and grounding (earthing) must conform to local wiring codes.
Be certain that a grounding conductor is connected to terminal T11-1 located in the
wiring compartment.
WARNING
! Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage pump and may result in
cord). To reduce risk of electric shock, be certain that power cord is connected only to a properly grounded,
grounding type receptacle.
! Permanently connected models must be properly grounded. Be certain that a grounding conductor is connected
to terminal T11-1 located in the wiring compartment.
! Never strap control (input / output) cables and power cables together.
! Power Interruption: This pump has an auto-restart feature which will restore pump to operating state it was in
when power was lost.
Note: When in doubt regarding your electrical installation, contact a licensed electrician.
WIRING COMPARTMENT COVER
5.99 in.
(152.1 mm)
.50
(12.7 mm)
2-PLCS.
.84 in.
(21.3 mm)
3-PLCS.
115V 60Hz
NEMA 5/15 (USA)
max: 125V AC
230V 60Hz
NEMA 6/15 (USA)
max: 250V AC
.50 INCH (12.7 mm) LIQ-TIGHT HOLE PLUGS (MATL = NEOPRENE), PRE-INSTALLED
.875 INCH (22.2 mm) LIQ-TIGHT HOLE PLUGS (MATL = NEOPRENE), 2 PRE-INSTALLED
.50 INCH (12.7 mm) LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MATL = NYLON)
ACCEPTABLE CABLE DIAMETER .118 TO .255 INCH (3.0 TO 6.5 MM), NOT INSTALLED
.875 INCH (22.2 mm) METALLIC LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MATL = NYLON)
ACCEPTABLE CABLE DIAMETER .200 TO .395 INCH (5.1 TO =10.0 MM), 1 PRE-INSTALLED WITH POWER CORD MODELS
METALLIC LIQ-TIGHT CONNECTORS FOR .50 INCH FLEXIBLE CONDUIT (MATL = DIE CAST ZINC), NOT INSTALLED
240V 50Hz
CEE 7/VII (EU)
max: 250V AC
Page 9
Flex-Pro
Wiring Terminals and I/O Schematics
T3
DRY
RMT
COM
1
2
3
N.O.
FVS
COM
T5
FUNCTION
(-)
1 2 (+)
(-)
1 2 (+)
RELAY
OUT
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FV SENSOR ONLY
INPUT:
FVS SYSTEM
(FLOW VERIFICATION
SENSOR)
FS or FP MICRO-FLO
FLOWMETER ONLY
INPUT:
REMOTE
START / STOP
(DRY CONTACT C.)
INPUT:
REMOTE
START / STOP
(WET CONTACT C.)
OUTPUT:
4-20 mA
OUTPUT:
FREQUENCY OPEN COLLECTOR
OUTPUT:
RELAY, 6 AMP
OUTPUT:
CONTACT
CLOSURE 1
OUTPUT:
CONTACT
CLOSURE 2
OUTPUT:
CONTACT
CLOSURE 3
INPUT:
POWER
FUSE
COM
N.C.
N.O.
N.C.
3
2
N.O.
NEUTRAL
(COMMON)
LINE
(HOT)
0-1000 HZ MAX.
(-) NEGATIVE
T2
(+) POSITIVE
T1
(-) NEGATIVE
T4
(+) POSITIVE
T4
SIGNAL
T4
(-) NEGATIVE
T4
(+) POSITIVE
T4
SIGNAL
T4
(-) NEGATIVE
T3
(-) NEGATIVE
T3
(+) POSITIVE
T3
(+) POSITIVE
T3
(-) NEGATIVE
T6
(+) POSITIVE
T6
(-) NEGATIVE
T5
(+) POSITIVE
T5
(-) NEGATIVE
T7
NORM. CLOSED
T7
COMMON
T7
NORM. OPEN
T8
NORM. OPEN
T8
COMMON
T8
NORM. CLOSED
NORM. OPEN
T9
COMMON
T9
NORM. CLOSED
T10
NORM. OPEN
T10
COMMON
T10
NORM. CLOSED
T11
GROUND
T11
NEUTRAL
T11
LINE (HOT)
5 AMP
(-) NEGATIVE
F1
(+) POSITIVE
T1
NA
CC2
WARNING
GROUND
ELECTRICAL SP.
(+) POSITIVE
F1
T9
120 OHM
IMPEDANCE, NON
POWERED LOOP
CC1
POWER
T11
RATING
T1
T9
2
3
1
2
3
1
2
3
T10
CC3
1 2 3
TERMINAL PIN #
T1
N.O.
COM
T7
T1
INPUT:
FREQUENCY, AC
SINE WAVE, TTL,
CMOS
INPUT:
0-10V DC
N.C.
T6
N.C. COM.
INPUT:
4-20 mA
OUTPUT
1 T8
(-)
SIG
1 2 3
T1
PULSE
GND (-)
4-20 (+)
1
2
3
T1
PULSE
GND (-)
4-20 (+)
T1
T1
PULSE
(+)
ACTIVE 4-20mA
TRANSMITTER
SOURCE
(-)
FREQUENCY
TRANSMITTER
(+) SOURCE
(-)
1
2
4-20 (+) 3
GND (-)
(+)
(-)
1
2
3
1
GND (-) 2
4-20 (+) 3
PULSE
T4
T2
SIG
0-10V DC
TRANSMITTER
(+) SOURCE
1
+15VDC 2
0-10 (+)
BLACK (-)
(-)
1 2 3
BARE
FVS
BLUE-WHITE
FVS SENSOR
RED (+)
(+)
T4
SIG
NEGATIVE (-)
(-)
1 2 3
RMT
COM
6 TO 30 VOLT DC
1 AMP MAX.
RMT
COM
120 OHM
RESISTANCE
ACTIVE LOOP
OPEN COLLECTOR
0-1000 Hz
50% DUTY CYCLE
Form C
6 AMP MAX AT
250 VAC,
5 AMP MAX AT
30 VOLT DC
Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC
Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC
Form C
1 AMP MAX AT
125 VOLT AC,
0.8 AMP MAX AT
30 VOLT DC
96 TO 264 VOLT AC,
50 / 60 HZ
A3 = 220W
A4 = 350W
5A SLOW BLOW
(20 X 5MM)
(+)
(+)
1
2
3
DRY
T3
1
2
3
DRY
T3
IMPEDANCE MUST
BE GREATER THAN
50K OHM
EXTERNAL DEVICE
6 TO 30V DC
(-)
T6
(-)
BLUE-WHITE
MICRO-FLO
FLOWMETER
PULSE OUTPUT
SIGNAL
FVS
NO VOLTAGE
BLOCK DIAGRAM
(OPTIONALPUMP#2)
4-20mA
T2
(+)
T4
(-)
(+)
1 2 (+)
T5
FREQ.
T1
1
GND (-) 2
4-20 (+)
3
0-10 (+) 1
+15VDC 2
4-20mA
INPUT
PULSE
FREQ.
2.5
(-)
4-20mA RECEIVER
600 OHM LOAD MAX.
DIGITAL PULSE
RECEIVER CIRCUIT
(+)
(-)
1 2 (+)
1.5K OHM
NC
C
T7
NO
RELAY
OUT
EXTERNAL SOURCE
6-30V DC
SWITCH LOAD
6 AMP MAX @ 250V AC
5 AMP MAX @ 30V DC
1 2 3
1
2
3
N.O.
COM
N.C.
T8
NO
CC1
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NC
1
2
3
N.O.
COM
N.C.
T9
CC2
NO
C
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NC
NO
1
2
3
N.O.
COM
N.C.
CC3
T10
T11GROUND
NEUTRAL
(COMMON)
LINE
(HOT)
SWITCH LOAD
1 AMP MAX @ 125V AC
0.8 AMP MAX @ 30V DC
NC
Page 10
3.0
Flex-Pro
ProSeries
P
Pr
roSer
Se
S
erriie
er
ies
es
by Blue-Wh
Blue-White
White
Wh
e In
Ind.
d
Industries,
Ltd.
ProSeries
P
Pr
roSe
ro
oSer
erriiie
es
by Blue-Wh
Blue-White
White
e In
Ind.
d
Industries,
Ltd.
Page 11
Flex-Pro
3.1
Menu Navigation
- Menu
+ Configuration
+ Input Setup
+ Pump Output
<- Esc
Within Menu of pump, each screen you enter will have a title located along top.
This will display the menu that is currently active, or this will be the setting you
are configuring.
To back out of menu, select <- Esc line located at end of list. Then press
ENTER button. This will take you back one level.
When menu list extends above or below height of display, a scroll bar will
appear on left side. Press DOWN arrow to scroll down to end of list to see a list
of all available options.
Scroll bar example:
While making a selection where only one choice is allowed, you will see a radio
button.
Radio button example:
Solid black means item is selected
Outline with no fill means item is not selected
In a screen where you are making changes, you will see the word Done
located at bottom of list. You must select Done in order to leave screen
(whether you made a change or not). Selecting Done will take you back to
parent level.
When inputting a numerical value, use UP or DOWN arrow to scroll through 0 9. To move over to next digit use RIGHT arrow. If you pass your desired digit,
you can continuously press RIGHT arrow until you scroll reach to your desired
digit.
Numeric value example:
0 000
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Display Rate
%Speed
RPM
ML/min
Oz/min
Liter/Hr
- Display Rate
Oz/min
Liter/Hr
Gal/Hr (US)
Gal/day (US)
Done
Page 12
3.2
Flex-Pro
Configuration Menu
Below is menu structure for Configuration screens.
- Menu
+ Configuration
+ Input Setup
+ Pump Output
<- Esc
Display Language
Display Rate
Set Password
Reset to Defaults
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Display Language
English
Spanish
German
French
Done
- Set Password
Enter Password:
- Display Rate
%Speed
RPM
ML/min
Oz/min
Liter/Hr
0 000
OFF = 0000
Press ENTER when done.
Gal/Hr (US)
Gal/day (US)
Done
- Display Language
English
Spanish
German
French
Done
3.2.1
- Set Password
Setting your password to:
1234
Are you sure? No
Yes
dd
Hi
- Display Rate
Oz/min
Liter/Hr
Gal/Hr (US)
Gal/day (US)
Done
Language Selection
- Menu
+ Configuration
+ Input Setup
+ Pump Output
<- Esc
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Display Language
English
Spanish
German
French
Done
Page 13
Flex-Pro
3.2.2
By default, pump will display %Speed (motor speed) and RPM. It is recommended you select an additional Display Rate. After selecting another Display
Rate (such as ML/Min), pump will still display %Speed and RPM along with
your selected Display Rate.
Press MENU button to enter menu structure for setting up pump.
Select Configuration and Press ENTER button.
Select Display Rate and Press ENTER button.
Select your desired Display Rate (unit of measure). Note: %Speed and RPM
will always be active and available to view when pump is in operation.
Select Done at bottom of list to confirm your selection and to return back to
previous screen. Press ENTER button.
Select <-Esc on following screens to move back up to desired menu location.
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Display Rate
%Speed
RPM
ML/min
Oz/min
Liter/Hr
- Display Rate
Oz/min
Liter/Hr
Gal/Hr (US)
Gal/day (US)
Done
Tip!
While pump is operating in any Run Mode, you can view
%Speed, RPM, plus another Display Rate (depending on
your selection above). Press RIGHT arrow while pump is
in any Run Mode. RIGHT arrow is a convenient way to
scroll through multiple read-only screens during normal
operating mode of pump.
Note: This is a read-only feature, no changes can be
made while in Run Mode.
3.2.3
This will reset pump to factory defaults. This will restore pump to original configuration when it left the factory.
Press MENU button to enter menu structure for setting up pump.
Select Configuration and Press ENTER button.
- Configuration
+ Display Language
+ Set Password
+ Display Rate
+ Reset to Factory Defaults
<- Esc
- Reset to Factory Defaults
Select <-Esc on the following screens to move back up to desired menu location.
Page 14
4.0
Flex-Pro
Input Setup
Below is the menu structure for the INPUT SETUP selection.
- Menu
+ Configuration
+ Input Setup
+ Output Setup
+ Power Fail option
<- Esc
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
Password Protect
Enter Password:
1 25.0
7 890
Use direction keys
Press ENTER to set.
en
dd
Hi
- Max Flowrate
Input Max Flowrate:
1 0000.0
Flowrate = ML/min
Press ENTER to set.
en
dd
Hi
- Input Setup
+ Manual Adjust
+ 4-20 mA Input
+ 0-10 VDC Input
+ Frequency Input
+ Pulse Input
en
dd
Hi
+ Cycle Adjustment
+ Dispensing
+ Manual Dosing
+ Proportional
<- Esc
en
dd
Hi
- Contact Input
Close: Stop Pump
Open: Stop Pump
Disable
Done
(select one)
en
dd
Hi
- Set FVS
Input Time Delay:
0 00
OFF = 000
Range = 1-255 sec
en
dd
Hi
TFD Sensitivity
% Sensitivity:
- Input Setup
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
<- Esc
0 78.0
Enter TFD Sensor
Sensitivity %.
en
dd
Hi
- Input Setup
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
- Remote/Local
Remote Only
Local Only
Disable
Done
(select one)
<- Esc
en
idd
en
dd
Hi
Page 15
Flex-Pro
4.1
The maximum motor RPM can be limited to reduce the possibility of overfeeding
chemical into the system. Note that the pumps display will still reference values
calculated from the 100% motor speed MAX Flowrate value (see section 4.2). Also,
the pump % motor speed will still be referenced from 125 RPM, the maximum
possible motor RPM. For example, if the pump speed is set for 25%, the display will
indicate 32.3 RPM. The prime mode RPM is limited to the Max RPM value.
Select Max RPM cut-off and Press ENTER button. Use the direction arrows to
enter the password 7890.
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
Password Protect
Enter Password:
7 890
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired digit,
you can easily scroll back by continuously pressing RIGHT button.
4.2
1 25.0
Press ENTER to set.
The MAX Flowrate value is equal to the pumps measured fluid output in milliliters
per minute, at the 100% motor speed adjustment setting. The pump uses the MAX
flow rate value to calculate motor speed for various operating functions and to
display output values.
Each Flex-Pro pump is calibrated at the factory and shipped with a calibrated pump
tube assembly installed. The MAX flow rate value can be adjusted at any time. To
achieve high accuracy, a field calibration under the actual operating conditions
should be performed and the Max Flowrate value changed to reflect the calibrated
amount. Multiply the Max Flowrate value by the percentage of error at your
calibrated flow rate to obtain the new Max Flowrate value.
Select Max Flowrate and Press ENTER button.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired digit,
you can easily scroll back by continuously pressing RIGHT button.
- Input Setup
+ Max RPM cut-off
+ Max Flowrate
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
+ Set Rev Alarm
<- Esc
en
dd
Hi
- Max Flowrate
Input Max Flowrate:
1 0000.0
Flowrate = ML/min
Press ENTER to set.
Select <-Esc on the main menu screen to exit the menu structure and enter the run
Flowrate:
mode.
To determine the amount of
Every pump tube assembly model number has a published maximum flow rate
value which is based on laboratory tests pumping water at room temperature at 36
suction lift against 0 psi back pressure. Your actual output may vary due to fluid
viscosity, fluid temperature, suction lift height, piping system layout, manufacturing
tolerances and to a lesser degree, variations in system pressure and tubing wear.
To achieve high accuracy, the pumps output should be measured (calibrated), and
the MAX Flowrate value (in milliliters per minute) updated, whenever any of the
following conditions exist:
Page 16
4.3
Flex-Pro
Tip!
4.3.1
Manual
Manual Speed
SpeedAdjust
Adjust
OFF
Press START to run
Used to manually control speed of pump. Use up and down arrows to adjust
the speed while the pump is running or set % (percent) Motor Speed in this
menu.
Press SELECT RUN MODE button until Manual Speed Adjust is displayed in
the top line of the display.
To configure the pump output speed, navigate to Manual Speed Adjust menu
by using short-cut method described above, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Manual Adjust.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Tip!
Manual Speed Adjust
0 00.0%
Set % motor speed.
Press ENTER to set.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
- Speed Adjust
Input Pump Speed:
228
GAL/DAY
Displays current rotor direction
Page 17
Flex-Pro
4.3.2
4 - 20 mA Input
- 4-20 mA Input
Min mA Signal:
0 4.00
Input Min. mA signal Input.
Press ENTER to set.
4 mA = 0% motor speed
20 mA = 100% motor speed
Press SELECT RUN MODE button until 4 - 20 mA Input is displayed in the top
line of the display.
- 4-20 mA Input
% Motor @ Min Signal:
0 00.0%
- 4-20 mA Input
Max mA Signal:
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
2 0.00
Input Max. mA Signal Input
Press ENTER to set.
- 4-20 mA Input
% Motor @ Max Signal:
If you used short-cut to enter 4-20 mA input setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.
1 00.0%
Input % Motor Speed at
Maximum mA Signal
If you used Menu button to navigate to 4-20 mA input setup, you must navigate
back out of menu structure. To do this you must select <-Esc at bottom of every
screen menu until you see Run Mode screen displayed.
Example 1
Example 2
Example 3
4 mA = 0% Pump Output
20 mA = 100% Pump Output
75
100%
Output
Pump
Motor Speed (%)
Pump
Motor Speed (%)
100%
Output
50
25
0%
Output
0
4 6 8 10 12 14 16 18 20
Milliamp input (mA)
from external source
Pump
Motor Speed (%)
100
100
75
50
25
100
75
50
43.8%
Output
25
0%
Output
20%
Output
4 6 8 10 12 14 16 18 20
Milliamp input (mA)
from external source
Tip!
0
4 6 8 10 12 14 16 18 20
Milliamp input (mA)
from external source
- Screen Shot -
4-20 mA Input
12.5
mA
Page 18
Flex-Pro
4.3.3
0 0.00
Press SELECT RUN MODE button until 0 - 10 VDC Input is displayed in the top
line of the display.
0 00.0%
Input % Motor Speed at
Minimum Volt DC Signal
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
1 0.00
Continue this process until all four screens have been configured.
If you used short-cut to enter 0 - 10 VDC Input setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to 0 - 10 VDC Input setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.
Example 1
Example 2
Example 3
100%
Output
Pump
Motor Speed (%)
75
100%
Output
50
25
0%
Output
0
0
6
10
8
4
VDC Input
from external source
2
Pump
Motor Speed (%)
100
100
Pump
Motor Speed (%)
1 00.0%
75
50
25
100
75
50
45.3%
Output
25
0%
Output
0
0
20%
Output
6
10
8
4
VDC Input
from external source
2
Tip!
0
0
6
10
8
4
VDC Input
from external source
- Screen Shot -
12.5
VDC
Page 19
Flex-Pro
4.3.4
- Frequency Input
Min Frequency Signal:
Used to remotely control pump with an incoming high speed frequency signal.
Typically used with flow meters or other external devices.
Default settings:
0 000
Input Min. Freq. (Hz) signal
Press ENTER to set.
- Frequency Input
% Motor @ Min Signal:
Press SELECT RUN MODE button until Frequency Input is displayed in the
top line of the display.
0 00.0%
- Frequency Input
Max Frequency Signal:
1 000
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
- Frequency Input
% Motor @ Max Signal:
Continue this process until all four screens have been configured.
1 00.0%
If you used short-cut to enter Frequency Input setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to Frequency Input setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.
100
100%
Output
75
100%
Output
50
25
0%
Output
0
0
75
Pump
Motor Speed (%)
Pump
Motor Speed (%)
0 Hz = 0% Pump Output
1000 Hz = 100% Pump Output
100
Pump
Motor Speed (%)
Examples:
50
25
75
50
50%
Output
25
0%
Output
100
20%
Output
0
0
or
Injection
Point
Injection
Point
S3 Series | Hybrid Ultrasonic Flowmeter
NEMA 4X
IP 66
Ultrasonic
Flow Meter
Doppler /
Transit Time
Discharge
Line
ProSeries
TM
by Blue-White
Industries, Ind.
Ltd.
Discharge
Line
Paddlewheel
Flow Sensor / Meter
Page 20
Flex-Pro
Tip!
- Screen Shot -
Frequency Input
4.3.5
300
Hz
- Pulse Batch
Input Pulse Number:
Used to remotely control pump with an incoming pulse signal. Can be used with
an external foot pedal, a water meter, a PLC, contact closure, or other low speed
pulse devices.
Default settings:
0 001
Pulse Number for batch
Press ENTER to set.
Press SELECT RUN MODE button until Pulse Batch is displayed in the top line
of the display.
To configure the pump, navigate to Pulse Batch menu by using short-cut
method described at beginning of section, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Pulse Batch.
- Pulse Batch
% Motor Speed @ Batch:
1 00.0%
% Motor during batch.
Press ENTER to set.
- Pulse Batch
Pump On Time:
0 02.5
Run time during batch.
Max = 999999.9 Seconds
Tip!
- Screen Shot -
Pulse Batch
Pulse Number:
Page 21
Flex-Pro
4.3.6
Used to run at a pre-selected motor speed for a specified run time. This cycle
will repeat itself using a repeating cycle timer.
Default settings:
- Cycle Adjust.
Input Pump Speed:
0 00.0%
Set % pump speed.
Press ENTER to set.
Press SELECT RUN MODE button until Manual Cycle Adjust is displayed in
the top line of the display.
To configure the pump, navigate to Manual Cycle Adjustment menu by using
short-cut method described at beginning of section, or by pressing MENU
button, then selecting Input Setup, Input Modes, and then Cycle Adjustment.
- Cycle Adjust.
Input Duty On-Time:
0 01.5
Run-Time per cycle.
Max = 999999.9 seconds
- Cycle Adjust.
Total Cycle Time:
0 04.0
Repeating Timer.
Max = 999999.9 Seconds
Injection Point
Tip!
- Screen Shot -
Cycle (SEC.):
4.0
Page 22
Flex-Pro
4.3.7
Dispensing
- Dispensing
Volume to Dispense:
Configure any dispensing amount or sample size and pump will repeat it on
command by pressing START button. Great for accurate single shot dispensing
of a pre-configured volume.
Default settings:
1000 milliliters
50% pump speed
- Dispensing
Input Pump Speed:
Press SELECT RUN MODE button until Dispensing is displayed in the top line
of the display.
To configure the pump, navigate to Dispensing menu by using short-cut method
described at beginning of section, or by pressing MENU button, then selecting
Input Setup, Input Modes, and then Dispensing.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
Press ENTER to save changes.
Continue this process until all two screens have been configured.
If you used short-cut to enter Dispensing setup, then just press and hold Select
Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to Dispensing setup, you must navigate
back out of menu structure. To do this you must select <-Esc at bottom of every
screen menu until you see Run Mode screen displayed.
Tip!
Dispensing
001000.0
Input mL to dispense.
Press ENTER to set.
1500
ML
0 50.0%
Set % pump speed.
Press ENTER to set.
Page 23
Flex-Pro
4.3.8
Manual Dosing
- Manual Dosing
Dose Concentration:
Used to configure Parts Per Million dosing to a system. This method can be
used if treated fluid volume is a fixed amount (in Liters Per Minute). If treated
fluid volume is variable (continuous change), then use of a flow meter is recommended along with pumps Proportional Mode (next Run Mode).
Default settings:
Press SELECT RUN MODE button until Manual Dosing is displayed in the top
line of the display.
To configure the pump, navigate to Manual Dosing menu by using short-cut
method described at beginning of section, or by pressing MENU button, then
selecting Input Setup, Input Modes, and then Manual Dosing.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
1 .25
Specific Gravity of solution.
Press ENTER to set.
- Manual Dosing
Fluid Volume (LPM):
0010.00
- Manual Dosing
PPM to dose:
001.0
Continue this process until all four screens have been configured.
If you used short-cut to enter Manual Dosing setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to Manual Dosing setup, you must navigate
back out of menu structure. To do this you must select <-Esc at bottom of every
screen menu until you see Run Mode screen displayed.
- Screen Shot -
Manual Dosing
- Manual Dosing
Dose Specific Gravity:
Fluid to be treated.
1.0 - 9999.9 LPM
Tip!
0 1 2.5%
% of concentration.
Press ENTER to set.
% Concentration:
12.5
Spec. Gravity:
1.25
Page 24
Flex-Pro
4.3.9
Proportional Dosing
- Proportional Dosing
Dose Concentration:
Used to configure proportional Parts Per Million dosing to a system. This method
of proportional dosing is based off input pump is receiving from an external flow
meter. Flow meter must have a pulse output. You will need to refer to flow meter
instruction manual to obtain K-factor for flow meter.
Default settings:
012.5%
Percentage of concentration.
Press ENTER to set.
- Proportional Dosing
Dose Specific Gravity:
1 .25
Specific Gravity of solution.
Press ENTER to set.
- Proportional Dosing
Input K-Factor (pulses):
0005.0000
Pulses Per Liter.
0.0001 - 9999.9999
- Proportional Dosing
PPM to dose:
001.0
Continue this process until all four screens have been configured.
If you used short-cut to enter Proportional Dosing setup, then just press and hold
Select Run Mode button until Run Mode screen is displayed.
If you used Menu button to navigate to Proportional Dosing setup, you must
navigate back out of menu structure. To do this you must select <-Esc at bottom
of every screen menu until you see Run Mode screen displayed.
or
Injection
Point
Injection
Point
S3 Series | Hybrid Ultrasonic Flowmeter
NEMA 4X
IP 66
Ultrasonic
Flow Meter
Doppler /
Transit Time
Discharge
Line
ProSeries
TM
by Blue-White
Industries, Ind.
Ltd.
Discharge
Line
Paddlewheel
Flow Sensor / Meter
Page 25
Flex-Pro
Tip!
- Screen Shot -
- Screen Shot -
Proportional Dosing
4.4
300
Proportional Dosing
% Concentration:
12.5
Spec. Gravity:
1.25
Hz
Disable
CC Input Range:
6 - 30 VDC
or
Dry Contact Closure (no voltage required)
[See section 5.1 for wire connections]
- Menu
+ Configuration
+ Input Setup
+ Pump Output
<- Esc
- Input Setup
+ Motor - Select RPM
+ Tubing - Max Flowrate
+ Operating Input Modes
+ Contact Closure Input
+ Set FVS
<- Esc
de
Hid
Navigate to Contact Input menu by MENU button, then selecting Input Setup,
and then Contact Input.
- Contact Closure Input
Close: Stop Pump
Open: Stop Pump
Disable
Done
Press DOWN arrow to scroll down to Done selection. Then press ENTER.
To navigate back out of menus, select <-Esc and press the ENTER button at
bottom of every screen menu until you see Run Mode screen displayed.
IMPORTANT: If Contact Closure Input is enabled, pump will display STANDBY if
pump is in Stop mode via the Contact Closure. Please use caution in this
mode. Pump can Start at anytime. If you must perform maintenance to the
pump, Press STOP button.
When Contact Closure Input is enabled, the word Remote will be displayed on
lower left side of screen at all times.
STANDBY
Waiting for SIGNAL...
REMOTE
Signal started pump
228
REMOTE
GAL/DAY
Page 26
- Input Setup
+ Motor - Select RPM
+ Tubing - Max Flowrate
+ Operating Input Modes
+ Contact Closure Input
+ Set FVS
<- Esc
Hidden
4.5
Flex-Pro
000 (off)
Navigate to Set FVS menu by pressing MENU button, then selecting Input
Setup, and then Set FVS.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired
digit, you can easily scroll back by continuously pressing RIGHT button.
- Set FVS
Input FVS Time Delay:
0 00 Seconds
OFF = 000
Range = 001-255 seconds
STOP
If FVS alarm occurs, pump will stop, send an external signal (if setup), and
screen will flash FVS with an alarm icon.
To clear FVS alarm, you must press START button or re-cycle power (unplug
power to pump, then plug back in).
Install FVS Flow Sensor - Flow Verification Sensor (FVS) should be installed
on the inlet (suction) side of the pump tube. Sensor includes a PVC tubing
insert, located inside sensors female thread connection, that is designed to
seal sensor onto pump tube inlet adapter. Thread sensor onto pump tube until
tubing insert is snug against pump tube inlet fitting - do not over-tighten.
Confirm the FVS flow range - Flow Verification Sensor (FVS) will only
function within its operating range. Sensor model FV-100 has an operating
range of 30-300 ml/min (1-10 oz/min) when used as a flowmeter. However, due
to pressure drop across the sensor, the pumps suction capability is limited to
14.7 psi. Therefore, when used with the peristaltic pump as a flow verification
sensor, the effective operating range is reduced to 30-200 ml/min. Note that if
the pumps output is less than 30 ml/min, the sensor will not detect chemical
and a signal will not be sent to pump.
SENSOR
MODEL
NUMBER
FV-100
FV-200
FV-300
FV-400
FV-500
FV-600
PUBLISHED
FLOW RANGE
(ml/min)
30-300
100-1000
200-2000
300-3000
500-5000
700-7000
30-200
50-900
100-1800
300-3000
500-5000
700-7000
FVS
ALARM
Page 27
Flex-Pro
4.6
STOP
4.6.1
TFD
ALARM
TFD Adjustment
Flex-Pro Tube Failure Detection (TFD) sensitivity can be adjusted through the
menu. Default setting (75% sensitivity) will trigger an alarm with most water
treatment chemicals with no false triggering.
- Menu
+ Configuration
+ Input Setup
+ Output Setup
<- Esc
CAUTION
- Input Setup
+ Input Setup
+ Contact Input
+ Set FVS
+ Set TFD
+ Set FVS
TFD Sensitivity
% Sensitivity:
075.0
Enter TFD Sensor
Sensitivity %
Page 28
4.7
Flex-Pro
Remote/Local Control
The Flex-Pro can be configured for Remote control only, Local control only, or
either (disabled).
When set for Remote control only, all touch pad buttons except the menu button are
disabled. To completely lock out the menu, configure a password (see page 12,
section 8). If REMOTE ONLY is selected, the user is prompted to select an input
operating mode which must then be used when operating the pump.
When set for local control only, all input signals including the remote start/stop are
disabled. Note that the contact closure input menu setting (section 4.4) is
switched to disabled while LOCAL ONLY is selected. This menu setting will return
to the previous setting when REMOTE ONLY or DISABLED is selected.
- Input Setup
+ Input Modes
+ Contact Input
+ Set FVS
+ Set TFD
+ Remote/Local
+ Set Rev Alarm
<- Esc
en
dd
Hi
- Remote/Local
Remote Only
Local Only
Disable
Done
(select one)
Tip!
MAINTENANCE MODE
Pump Cover Removed!
MAINTENANCE MODE
- Cover was removed!
- Motor Speed = 6 RPM
4.8
en
dd
Hi
+
PUMP TUBE TIMER
Current tube timer:
186
Hrs.
Page 29
Flex-Pro
- 4-20 mA Output
Signal @ min % Motor:
- Freq. Output
Signal @ Min % Motor:
04.00
0 000
Input mA Signal
@ Min % Motor speed
- 4-20 mA Output
Maximum % Motor:
- Freq. Output
Maximum % Motor:
100.00
Input Maximum % Motor
for mA Signal output
- 4-20 mA Output
Signal @ Max % Motor:
20.00
Input mA signal
@ Max % Motor Speed
1 00.0
000.0
Max Delay = 999.9 (s)
Press ENTER to set
H
id
de
n
- Output Setup
+ Signal Output Modes
+ Relay Output
+ Contact #1
+ Contact #2
+ Contact #3
<- Esc
- Contact Closure #1
Pump Run/Stop
Monitor Input
Monitor Output
Monitor Run/Fail
Both, TFD/FVS
TFD
FVS
Manual Mode
4-20mA Mode
0-10 VDC Mode
Frequency Mode
Pulse Mode
Cycle Timer Mode
Dispensing Mode
Manual Dosing Acive
Prop. Dosing Active
Remote Active
Reverse Alarm
General Error
Disable
Done
H
id
de
n
0 00.0
- Freq. Output
Minimum % Motor:
- Relay Output
Both, TFD/FVS
TFD
FVS
Pump Run/Stop
Monitor Input
Monitor Output
Monitor Run/Fail
Manual Mode
4-20mA Mode
0-10 VDC Mode
Frequency Mode
Pulse Mode
Cycle Timer Mode
Dispensing Mode
Manual Dosing
Prop. Dosing
Remote Active
Reverse Alarm
General Error
Disable
Done
de
000.0
- Signal Output
4-20 mA Output
Freq. Output
Disable
Done
(select one)
id
H
id
de
n
- Signal Output
4-20 mA Output
Freq. Output
Disable
Done
(select one)
- 4-20 mA Output
Minimum % Motor:
de
Output - Signal
- Output Setup
+ Signal Output
+ Relay Output
+ Contact #1
+ Contact #2
+ Contact #3
<- Esc
Note:
Contact #1 shown only. Contact #2, and
Contact #3 use the same menu items.
id
- Menu
+ Configuration
+ Input Setup
+ Output Setup
+ Power Fail option
<- Esc
5.0
Contact 1 Delay
Input Relay Delay:
000.0
Max Delay = 999.9 (s)
Press ENTER to set
1 000
Input Frequency (Hz)
@ Max % Motor Speed
Page 30
5.1
Flex-Pro
Signal Output
Sends a configurable 4 - 20 mA or frequency (Hz) signal to another pump or external device. This feature can be
used to control other pumps (in sync / proportionally), data logging systems, and other external devices for plant
automation.
Default settings:
Disable
Navigate to Signal Output menu by pressing MENU button, then selecting Output Setup, and then Signal
Output.
Select your desired Signal output using UP or DOWN arrows.
Press ENTER to configure output signal.
Press UP or DOWN arrow to scroll through 0 - 9 on selected digit.
Press RIGHT arrow to scroll over to next digit to right. If you pass your desired digit, you can easily scroll back by
continuously pressing RIGHT button.
Press ENTER to save changes.
Continue this process until all four screens have been configured.
To navigate back out of menu structure you must select <-Esc at bottom of every screen menu until you see Run
Mode screen displayed.
- Signal Output
4-20 mA Output
Frequency Output
Disable
Done
75
- Signal Output
4-20 mA Output
Frequency Output
Disable
Done
100
50
- 4-20 mA Output
Minimum % Motor:
25
000.0
Example 2
0% Pump Output = 4 mA
50% Pump Output = 16 mA
100
75
50
25
0
4 6 8 10 12 14 16 18 20
Milliamp Output (mA)
Signal
4 6 8 10 12 14 16 18 20
Milliamp Output (mA)
Signal
0% Pump Output = 0 Hz
100 % Pump Output = 1000 Hz
- Freq. Output
Minimum % Motor:
0 00.0
- 4-20 mA Output
Signal @ min % Motor:
- Freq. Output
Signal @ Min % Motor:
04.00
Input mA Signal
@ Min % Motor speed
- 4-20 mA Output
Maximum % Motor:
100.00
0 000
Input Frequency (Hz)
@ Min % Motor Speed
- Freq. Output
Maximum % Motor:
1 00.0
- 4-20 mA Output
Signal @ Max % Motor:
- Freq. Output
Signal @ Max % Motor:
20.00
Input mA signal
@ Max % Motor Speed
1 000
Input Frequency (Hz)
@ Max % Motor Speed
75
50
25
0
0
100
Example 1
- Frequency Output -
- 4 - 20 mA Output -
0% Pump Output = 4 mA
100 % Pump Output = 20 mA
Example 2
0% Pump Output = 1000 Hz
100% Pump Output = 0 Hz
100
Example 1
75
50
25
0
0
Page 31
Flex-Pro
6.0 Pump Maintenance
CAUTION
!
6.1
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
6.2
6.3
tation Direction
Ro
Outlet
FRONT
Inlet
FRONT
Swap Inlet
and Outlet
Page 32
6.4
Flex-Pro
Tube Replacement
Prior to service, pump clean water through the pump and suction / discharge line to remove
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
chemical.
Always wear protective clothing, face shield, safety glasses and gloves when working on
or near your metering pump. Additional precautions should be taken depending on
solution being pumped. Refer to MSDS precautions from your solution supplier.
Use provided Tube Installation Tool to leverage tubing into pump head, NOT YOUR
FINGERS.
Use extreme caution when replacing pump tube. Be careful of your fingers and DO NOT
place fingers near rollers.
Pump Head
Spacer, Rear
Rotor
Spacer, Front
Tubing Assembly
Pump Head Cover
Thumb
Screws
Remove Pump Head Cover by unscrewing four Thumb Screws. Pull out Pump
Head Cover.
MAINTENANCE MODE
Pump Cover Removed!
Pump will detect Pump Head Cover is removed and enter MAINTENANCE MODE.
Rotor will rotate at a maximum of 6 RPM for your safety.
Pull out suction side of Tubing Assembly.
MAINTENANCE MODE
Press START button. While rotor is rotating, pull out old Tube Assembly.
TIP! Let pump do the work for you. Just guide tubing out between two rollers
located on Rotor.
Press STOP button at any time to stop the pump.
Pull out suction line adapter from Pump Head. Pull out Tubing Assembly as the
Rotor rotates around.
Stop pump by pressing STOP button.
Thoroughly clean Pump Head and Rotor. Rotor can be removed by pulling straight
out. After cleaning process, push Rotor back on shaft. See drawing above for
proper assembly. IMPORTANT! Rotor direction; the word FRONT on Rotor must
face front of pump.
Locate your new tubing and Tube Installation Tool. Please see next page on how to
install new Tube Assembly into Pump Head.
Page 33
Flex-Pro
3
PULL
MAINTENANCE MODE
Pump Cover Detected!
MAINTENANCE MODE
Was Tube Replaced?
NO
YES
Up/Down to select
Press ENTER to set
Page 34
Norprene Chemical
Tygothane
Norprene
Norprene
6.5
Flex-Pro
Item
Description
Part Number
QTY
Pump Head
A3-SXX-H
76001-503
A3-SND-R
A3-SND-T
A3-MND-T
A3-SNF-T
A3-MNF-T
Roller Assembly Complete (Rotor), For NH, NJ, NK, NKL Tubes
A3-SNH-R
A3-SNH-T
A3-MNH-T
A3-SNJ-T
A3-MNJ-T
A3-SNK-T
A3-MNK-T
Tube Assy, 3/8 tube cont, Norprene NKL (.375 ID) Low Pressure (30 psi max)
A3-SNKL-T
Tube Assy, 1/2 Male NPT, Norprene NKL (.375 ID) Low Pressure (30 psi max)
A3-MNKL-T
A3-SGE-R
A3-SGE-T
A3-MGE-T
A3-SGG-T
A3-MGG-T
A3-SGH-T
A3-MGH-T
A3-SGK-T
A3-MGK-T
A3-STH-R
A3-STH-T
A3-MTH-T
A3-STK-T
A3-MTK-T
Spacer, Front
90011-014
A3-SXX-C
Thumb Screw
90011-183
Not
Shown
Not
Shown
Not
Shown
C-330-6
72000-379
72000-380
Rubber feet
90003-561
4
6
7
2
3
Page 35
Flex-Pro
6.6
QTY
76001-503
A4-MNH-R
A4-BNH-T
A4-MNH-T
A4-BNJ-T
A4-MNJ-T
A4-BNK-T
A4-MNK-T
A4-MNL-R
A4-BNL-T
A4-MNL-T
A4-BNP-T
A4-MNP-T
Item
Norprene
Norprene
Norprene Chemical
Norprene and
Tygothane
Description
Roller Assy Complete (A4 Rotor), For NKL, NHH, NKLL, TH, TK, THH, TKK Tubes
A4-MTH-R
A4-MNKL-T
A4-BNKL-T
Tube Assy, 1/2 hose barb, Dual Norprene NH & NH (.25 + .25 ID)
A4-BNHH-T
Tube Assy, 1/2 Male NPT, Dual Norprene NH & NH (.25 + .25 ID)
A4-MNHH-T
Tube Assy, 1/2 hose barb, Dual Norprene NKL & NKL (.38 +.38 ID)
A4-BNKKL-T
Tube Assy, 1/2 Male NPT, Dual Norprene NKL & NKL (.38 + .38 ID)
A4-MNKKL-T
A4-BTH-T
A4-MTH-T
A4-BTK-T
A4-MTK-T
Tube Assy, 1/2 hose barb, Dual Norprene Chemical TH & TH (.25 +.25 ID)
A4-BTHH-T
Tube Assy, 1/2 Male NPT, Dual Norprene Chemical TH & TH (.25 + .25 ID)
A4-MTHH-T
Tube Assy, 1/2 hose barb, Dual Norprene Chemical TK & TK (.38 +.38 ID)
A4-BTKK-T
Tube Assy, 1/2 Male NPT, Dual Norprene Chemical TK & TK (.38 + .38 ID)
A4-MTKK-T
Roller Assy Complete (A4 Rotor), For GH, GK, GHH, GKK Tubes
A4-MGH-R
A4-BGH-T
A4-MGH-T
A4-BGK-T
A4-MGK-T
Tube Assy, 1/2 hose barb, Dual Tygothane GH & GH (.25 + .25 ID)
A4-BGHH-T
Tube Assy, 1/2 Male NPT, Dual Tygothane GH & GH (.25 + .25 ID)
A4-MGHH-T
Tube Assy, 1/2 hose barb, Dual Tygothane GK & GK (.38 + .38 ID)
A4-BGKK-T
Tube Assy, 1/2 Male NPT, Dual Tygothane GK & GK (.38 + .38 ID)
A4-MGKK-T
72000-379
72000-380
Rubber feet
90003-561
Not
Shown
Not
Shown
Not
Shown
2
2
3
76001-439, Shaft extension
Page 36
Flex-Pro
A3
A3
A3
A3
Page 37
Flex-Pro
A4
A4
A4
A4
LIMITED WARRANTY
Your new Flex-Pro pump is a quality product and is warranted for 24 months from date of purchase (proof of purchase is required). The
pump will be repaired or replaced at our discretion. Pump Head and roller assembly is warrantied against damage from chemical
attack when proper TFD (Tube Failure Detection) system instructions and maintenance procedures are followed.
Blue-White Industries does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out of
the use of its products. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the
product other than in normal operation as defined in the pump manual.
Warranty status is determined by the pump's serial label and the sales invoice or receipt. The serial label must be on the pump and
legible. The warranty status of the pump will be verified by Blue-White or a factory authorized service center.
OTHER IMPORTANT WARRANTY INFORMATION
Please be advised; injection and metering devices are not intended as a means of treating water to render it suitable for human
consumption. When used as hypochlorinators, they are meant to destroy bacteria and algae contamination, before its removal by
filtration. Acid and soda injectors are used for PH control (balance). Blue-White injectors are factory tested with water only for pressure
and performance. Installers and operators of these devices must be well informed and aware of the precautions to be taken when
injecting various chemicals -especially those considered hazardous or dangerous, eye protection must be worn when working around
this product or any other metering type of pump.
Should it become necessary to return the pump for repair or service, you must attach information regarding the chemical used as some
residue may be present within the unit which could be a hazard to service personnel.
Blue-White Industries will not be liable for any damage that may result by the use of chemicals with their injectors and its components.
Thank you.
PROCEDURE FOR IN WARRANTY REPAIR
Contact the factory to obtain a RMA (Return Material Authorization) number. Carefully pack the pump to be repaired. It is recommended
to include foot strainer and injection/check valve fitting since these devices may be clogged and part of the problem. Please enclose a
brief description of the problem as well as the original invoice or sales receipt, or copy showing the date of purchase. Prepay all
shipping costs. COD shipments will not be accepted. Warranty service must be performed by the factory or an authorized ProSeries
service center. Damage caused by improper packaging is the responsibility of the sender. When In-Warranty repair or replacement is
completed, the factory pays for return shipping to the dealer or customer.
Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not
dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return,
recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the
presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway.
Appliances are labeled in accordance with European Directive 2002/96/EC.
Contact your local waste recovery agency for a Designated Collection Facility in your area.
ProSeries
TMR
by Blue-White Ind.
Rev. 06182012