3g Ue Timers
3g Ue Timers
3g Ue Timers
Start
Stop
At expiry
T300
Retransmit RRC
CONNECTION
REQUEST if V300 =<
N300, else go to Idle
mode
T302
Transmission of
CELL
UPDATE/URA
UPDATE
Retransmit CELL
UPDATE/URA
UPDATE if V302 =<
N302, else, go to Idle
mode
T304
Transmission of Reception of UE
UE CAPABILITYCAPABILITY
INFORMATION INFORMATION
CONFIRM
Retransmit UE
CAPABILITY
INFORMATION if
V304 =< N304, else
initiate a cell update
procedure
T305
Entering
Entering another state.
CELL_FACH or
URA_PCH or
CELL_PCH state.
Reception of
CELL UDPATE
CONFIRM/URA
UPDATE
CONFIRM.
Transmit CELL
UPDATE if T307 is
not activated and the
UE detects in service
area. Otherwise, if
T307 is not active, start
T307.
T307
T308
Transmission of
2015-05-10
Reception of CELL
UPDATE
CONFIRM/URA
UPDATE CONFIRM
Not stopped
Transmit RRC
Page1, Total7
Timer
Start
RRC
CONNECTION
RELEASE
COMPLETE
Stop
At expiry
CONNECTION
RELEASE
COMPLETE if V308
<=N308, else go to
idle mode.
T309
T310
Transmission of
PUSCH
CAPACITY
REQUEST
Reception of
Transmit PUSCH
PHYSICAL SHARED CAPACITY
CHANNEL
REQUEST if V310 =<
ALLOCATION
N310, else procedure
stops.
T311
Reception of
PHYSICAL
SHARED
CHANNEL
ALLOCATION
message with the
CHOICE
PUSCH
allocation set to
PUSCH
allocation
pending.
Reception of
UE may initiate a
PHYSICAL SHARED PUSCH capacity
CHANNEL
request procedure.
ALLOCATION
message with
CHOICE PUSCH
allocation set to
PUSCH allocation
assignment.
T312
When the UE
When the UE detects The criteria for
starts to establish N312 in sync
physical channel
dedicated CH
indication from L1.
establishment failure is
fulfilled
T313
When the UE
When the UE detects The criteria for Radio
detects
consecutive N315 in Link failure is fulfilled
consecutive N313 sync indication from
out of sync
L1.
indication from
L1.
T314
When the criteria When the Cell Update See subclause 8.3.1.13
for radio link
procedure has been
failure are
completed.
fulfilled.
2015-05-10
Page2, Total7
Timer
Start
Stop
At expiry
T315
When the criteria When the Cell Update See subclause 8.3.1.14
for radio link
procedure has been
failure are
completed.
fulfilled.
The timer is started
only if radio
bearer(s) that are
associated with
T315 exist.
T316
When the UE
When the UE detects
detects out of
in service area.
service area in
URA_PCH or
CELL_PCH state
T317
Counters for UE
2015-05-10
Page3, Total7
Counter Reset
Incremented
V300
V302
V304
When sending the Upon expiry of T304 When V304 > N304
first UE
the UE initiates the
CAPABILITY
Cell update procedure
INFORMATION
message.
V308
V310
Usage
N300
2015-05-10
Page4, Total7
Constant
Usage
N302
N304
N308
N310
N312
N313
N315
2015-05-10
Page5, Total7
T300 can be set to one of the following values: 400, 600, 800, 1000, 1200, 1400,
1600, 1800, 2000, 3000, 4000, 6000, 8000 ms.
2015-05-10
Page6, Total7
N315 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200,
400, 600, 800, 1000.
2015-05-10
Page7, Total7