Catalouge SN1
Catalouge SN1
Catalouge SN1
ISO 9001
ISO 14001
R410A
R410A
Energy
Energy Saving
Saving
Thanks to Hitachis unique energy-saving technology
such as the high-efficiency DC inverter compressor,
industry-leading COP has been achieved.
Easy
Easy Installation
Installation
All-in-one compact design for all models of outdoor
units. Simplifies the installation and increases the
flexibility of location.
Comfort
Comfort
Fine temperature setting and noise reduction
technology for comfortable air conditioning.
Reliability
Reliability
Hitachis long scroll compressor
experience ensures greater reliability.
Vector-control DC Inverter
Newly-developed,
Energy-saving Heat Exchanger
Supercooling Circuit
Indoor Units
Capacity Range [HP]
1.0
1.5
2.0
2.5
3.0
4.0
5.0
RCI1.0FSN2
RCI1.5FSN2
RCI2.0FSN2
RCI2.5FSN2
RCI3.0FSN2
RCI4.0FSN2
RCI5.0FSN2
RCD1.0FSN2
RCD1.5FSN2
RCD2.0FSN2
RCD2.5FSN2
RCD3.0FSN2
RCD4.0FSN2
RCD5.0FSN2
RPI1.0FSN2
RPI1.5FSN2
RPI2.0FSN2
RPI2.5FSN2
RPI3.0FSN2
RPI4.0FSN2
RPI5.0FSN2
RPC2.0FSN2
RPC2.5FSN2
RPC3.0FSN2
RPC4.0FSN2
RPC5.0FSN2
0.8
8.0
10.0
RPI8FSN
RPI10FSN
4-Way Cassette
RCI-FSN2
Outdoor Units
Capacity Range [HP]
10
12
14
16
18
20
22
2-Way Cassette
RCD-FSN2
RAS5FSN
RPI0.8FSN2
In-the-ceiling
RPI-FSN(2)
RAS8FSN1
RAS10FSN1
RAS12FSN1
4
Ceiling
RPC-FSN2
RAS14FSN1
RAS16FSN1
RPK-FSNSM2
RAS18FSN1
RAS20FSN1
RAS22FSN1
RPF1.0FSN2E
RPF1.5FSN2E
RPFI1.0FSN2E
RPFI1.5FSN2E
Floor
RPF-FSN2E
Capacity Range [HP]
24
RAS24FSN1
26
RAS26FSN1
28
RAS28FSN1
30
RAS30FSN1
32
34
36
38
40
42
Floor Concealed
RAS32FSN1
RPFI-FSN2E
System Equipment
Capacity Range [m3/h]
RAS34FSN
RAS36FSN
RAS38FSN
RAS40FSN
RAS42FSN
Total Heat Exchanger
KPI
250
500
KPI2521
KPI5021
800
KPI8021
1,000
KPI10021
Supercooling Circuit
Performance improved by highefficiency plate type heat exchanger.
Effect of Subcooler
Refrigerating ability
increased by
supercooling circuit
Cooling Operation
Heating Operation
(%)
(%)
158% 149%
144% 140%
157%
150
COP
COP
150
100
160%
140%
141%
100
Conceptual Diagram
Cooling Operation
Heating Operation
Cooling Operation:
Cooling ability is enhanced by the sub-cooler.
8HP
10HP
16HP
20HP
8HP
10HP
16HP
20HP
Subcooler
Subcooler
Oil Separator
R410A
New Scroll Tooth Form
Compressor
s
Accumulator
s
Subcooler
Heat Exchanger for Supercooling
DC inverter motor
High-efficiency operation for
low- to high-speed airconditioning loads.
Receiver
Expansion Valve
for Supercooling
Patented
HP
s
Optimizing expansion
valve control
16HP
Inverter
Compressor
18
Cooling Load
Min.
Inverter
Compressor
No.2 Compressor
Inverter
Compressor
-5C
70Steps
-20
Cooling Load
Inverter
Compressor
No.4
Compressor
No.3 Compressor
No.2 Compressor
Min.
Min.
Cooling Load
Inverter Controled
Non-inverter Controled
Preset Temperature
Precise
Time
20
30
40
50
Excessive power
consumption exceeding the
power setting is curtailed.
Maximum efficiency
secured in a range below
NEW Wave function
the power setting
Daytime
Night
10C
Power Setting
10
10
10
10
10
10
10
10 (Min.)
Power Setting
10
10
10
10
10
10
10
10 (Min.)
Room Temp.
Effects of
Demand Control
10
Operation Time
Power Setting
Morning
Power Consumption
-10
Self-demand Control
43C
Self-demand Control
No.5
Compressor
7
Max
Cooling
30Hz~100Hz
100
70Steps
12
Max
15C
22HP
(%)
30Hz~100Hz
Compressor Control
Capacity
Compressor Control
Capacity
70Steps
Heating
-20C
Power Consumption
(%)
100
30Hz~100Hz
Compressor Control
Capacity
100
Power Consumption
8HP
(%)
Set Temp.
20C
Room Temp.
15C
Set Temp.
20C
Floor near
the outdoor unit
5C (Small).
Optimal
Performance!
Optimal
Performance!
Room Temp.
10C
Optimal
Performance!
Set Temp.
20C
10C (Large).
Optimal
Performance!
Flexibility of Installation
Industry-unique all-in-one compact design for all models,
simplified installation and increased flexibility of location!
Compact Design
Outside dimensions of the series are reduced, 10% less Installation Space,
and weight reduced by 19% on average compared with conventional series.
Conventional Model (16HP)
RAS-16FSN1
Reduced by
37%
Reduced by
RAS-42FSN
31%
3
2
*1) For 100m or more, the pipe diameter will be one size larger.
case the outdoor unit is installed at a higher level than indoor units.
*2) IfInthe
outdoor unit is installed lower than indoor units, the maximum
RAS-16FSG
RAS-16FSG
In Case of RAS-16FSN1
RAS-16FSG
RAS-10FSG
In Case of RAS-42FSN
NOTES:
( ): Max. number of min. capacity
indoor units connectable.
HITACHI
SET-FREE FSN Series
2 outdoor Units
Installed
Power Source,
Grounding Wire
Transmission
Line
Power Source,
Grounding Wire,
Transmission Line,
Connecting Wire
Power Source,
Grounding Wire
Outdoor
Connecting Pipes
(Gas, Liquid)
Transmission
Line
Outdoor
Connecting Kits
(Gas, Liquid)
Gas Pipe
Liquid Pipe
Conventional Model
Outdoor Unit
Capacity
Min. Capacity of
Indoor Units Connectable
Max. Number of
Indoor Units Connectable
Outdoor Unit
Capacity
0.8 HP
0.8 HP
8 (8)
8 (8)
26 HP
0.8 HP
8 HP
0.8 HP
0.8 HP
13 (13)
13 (13)
28 HP
0.8 HP
10 HP
0.8 HP
0.8 HP
16 (16)
16 (16)
30 HP
Liquid Pipe
16 (16)
32 HP
0.8 HP
32 (12)
20 (20)
34 HP
0.8 HP
32 (12)
20 (20)
36 HP
0.8 HP
32 (12)
20 (20)
38 HP
0.8 HP
32 (12)
20 (20)
40 HP
0.8 HP
32 (12)
20 (20)
42 HP
0.8 HP
32 (12)
16 HP
1.0 HP
20 HP
24 HP
0.8 HP
16 (16)
0.8 HP
18 HP
1.0 HP
0.8 HP
16 (16)
0.8 HP
22 HP
1.0 HP
0.8 HP
27 (12)
27 (12)
Pipe Downsizing
5HP
8HP
10HP
12HP
14HP
16HP
18HP
Front
Downwards
20HP
22HP
Refrigerant-saving
24HP
26HP
Conventional Model
SET-FREE FSN
9.53
0.065 x 30 x 4=7.8kg
12.7
0,120 x 70=8.4kg
Pipe Size
Total
16.2kg(100%)
28HP
30HP
32HP
34HP
13.3kg (82%)
18%
32 (12)
0.8 HP
SET-FREE FSN
Liquid
Rear
31 (12)
32 (12)
0.8 HP
R407C Model
0.8 HP
29 (12)
14 HP
Supercooling
Circuit Effect
1.0 HP
Max. Number of
Indoor Units Connectable
12 HP
Gas Pipe
SET-FREE FSN
Min. Capacity of
Indoor Units Connectable
5 HP
36HP
38HP
40HP
42HP
9.53
9.53 -12.7
9.53 -12.7
12.7 -15.88
12.7 -15.88
12.7 -15.88
15.88 -19.05
15.88 -19.05
15.88 -19.05
15.88 -19.05
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
19.05 -22.2
(Pipe length
100m)
Gas
15.88
19.05 -22.2
22.2 -25.4
25.4 -28.6
25.4 -28.6
28.6 -31.75
28.6 -31.75
28.6 -31.75
28.6 -31.75
28.6 -31.75
31.75 -34.92
31.75 -34.92
31.75 -34.92
31.75 -34.92
31.75 -34.92
34.9 -41.3
34.9 -41.3
34.9 -41.3
34.9 -41.3
[%]
Difference in
Refrigerant
Properties
190%
100%
100
RAS-FSG
RAS-FSN
*Our Test Result
10
General Data
Outdoor Units
RAS-5FSN
Model
RAS-8FSN1
Power Supply
Nominal Cooling Capacity *1)
RAS-12FSN1
RAS-14FSN1
RAS-16FSN1
RAS-18FSN1
RAS-20FSN1
RAS-24FSN1
RAS-26FSN1
RAS-28FSN1
kW
14.5
23.3
29.1
34.9
40.7
46.5
52.3
58.1
64.0
69.8
75.6
81.4
12,500
20,000
25,000
30,000
35,000
40,000
45,000
50,000
55,000
60,000
65,000
70,000
Btu/h
49,700
79,400
99,300
119,100
138,900
158,800
178,600
198,500
218,300
238,100
258,000
277,800
kW
14.0
22.4
28.0
33.5
40.0
45.0
50.4
56.0
63.0
69.0
73.0
80.0
kcal/h
12,000
19,300
24,100
28,800
34,400
38,700
43,300
48,100
54,100
59,300
62,700
68,800
Btu/h
47,800
76,400
95,500
114,500
136,800
153,400
172,000
191,200
215,100
235,300
249,300
273,500
kW
16.0
25.0
31.5
37.5
45.0
50.0
56.0
63.0
71.0
77.5
82.5
90.0
kcal/h
13,800
21,500
27,100
32,200
38,700
43,000
48,100
54,100
61,000
66,600
70,900
77,400
Btu/h
54,600
85,300
107,500
128,000
153,900
170,400
191,200
215,100
242,500
264,200
281,800
307,700
Natural Gray
Natural Gray
Maximum
(Overall A Scale)
RAS-22FSN1
kcal/h
Cabinet Color
Maximum
(Night-Shift)
dB
52 (47)
56 (51)
58 (53)
60 (55)
61 (56)
62 (57)
62 (57)
62 (57)
63 (58)
63 (58)
63 (58)
64 (59)
Dimensions H x W x D
mm
kg
160
215
225
225
335
335
460
460
535
675
675
720
23.0
24.0
25.0
Net Weight
Refrigerant (Flow Control)
Refrigerant Charge
5.4
7.0
8.5
9.0
13.0
13.0
19.0
19.0
Hermetic (Scroll)
Compressor
Motor Output
kW
3.0 (4)
4.8 (4)
6.0 (4)
7.2 (4)
Propeller Fan
Condenser Fan
19.0
Hermetic (Scroll)
Heat Exchanger
Propeller Fan
87
138
172
185
210
210
344
344
344
382
382
382
(cfm)
(3,072)
(4,874)
(6,074)
(6,533)
(7,416)
(7,416)
(12,148)
(12,148)
(12,148)
(13,490)
(13,490)
(13,490)
kW
0.16 (8)
0.38 (8)
0.38 (8)
0.38 (8)
0.38 (8)
0.38 (8)
9.53
9.53-12.7
9.53-12.7
12.7-15.88
12.7-15.88
12.7-15.88
15.88-19.05
15.88-19.05
15.88-19.05
15.88-19.05
19.05-22.2
19.05-22.2
15.88
19.05-22.2
22.2-25.4
25.4-28.6
25.4-28.6
28.6-31.75
28.6-31.75
28.6-31.75
28.6-31.75
28.6-31.75
31.75-34.92
31.75-34.92
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
13
16
16
20
20
20
20
20
27
29
31
0.87
1.44
1.44
1.44
1.81
1.81
2.82
2.82
2.82
3.57
3.57
3.57
RAS-30FSN1
RAS-32FSN1
RAS-34FSN
RAS-36FSN
RAS-38FSN
RAS-40FSN
RAS-42FSN
Motor Output
11
RAS-10FSN1
Refrigerant Piping
Liquid
mm
Gas
m3
Model
Power Supply
87.2
97.2
93.0
102.3
108.4
114.5
119.5
kcal/h
75,000
80,000
83,700
88,000
93,300
98,500
102,800
Btu/h
297,700
317,500
332,000
349,400
370,200
390,000
408,100
kW
85.0
90.0
96.0
101.0
107.0
113.0
118.0
kcal/h
73,100
77,400
82,600
86,900
92,100
97,200
101,600
Btu/h
290,000
307,700
327,900
344,900
365,400
385,900
403,000
kW
95.0
100.0
108.0
113.0
119.5
127.0
132.0
113,600
kcal/h
81,700
86,000
92,900
97,200
102,800
109,300
Btu/h
324,200
341,900
368,800
385,900
408,100
433,700
Cabinet Color
Sound Pressure Level
450,800
Natural Gray
Natural Gray
Maximum
Maximum
(Night-Shift)
dB
64 (59)
64 (59)
64 (59)
64 (59)
65 (60)
65 (60)
65 (60)
Dimensions H x W x D
mm
kg
720
720
920
920
920
970
970
Refrigerant Charge
26.0
26.0
28.5
31.0
32.0
Motor Output
kW
Heat Exchanger
32.0
Hermetic (Scroll)
Hermetic (Scroll)
Compressor
Propeller Fan
Propeller Fan
Condenser Fan
382
554
554
554
554
554
(cfm)
(13,490)
(13,490)
(19,564)
(19,564)
(19,564)
(19,564)
(19,564)
kW
19.05-22.2
19.05-22.2
19.05-22.2
19.05-22.2
19.05-22.2
19.05-22.2
19.05-22.2
31.75-34.92
31.75-34.92
31.75-34.92
34.9-41.3
34.9-41.3
34.9-41.3
34.9-41.3
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
0.8 HP
32
32
32
32
32
32
32
3.57
3.57
4.99
4.99
4.99
4.99
4.99
Motor Output
Refrigerant Piping
Liquid
Gas
mm
m3
1. The above cooling and heating capacities show the capacities when the outdoor unit is operated with
the 100% rating of indoor units, and are based on the standard JIS B8616-1984.
Cooling Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
*1) 19.5C WB (67F WB)
*2) 19.0C WB (66.2F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Heating Operation Conditions
Indoor Air Inlet Temperature: 20C DB (68F DB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
6C WB (43F WB)
Piping Length: 7.5 Meters
(Overall A Scale)
Net Weight
NOTES :
12
Indoor Units
Indoor Units
IN Operation
OFF Operation
13
General Data
Model
Indoor Unit Power Supply
kW
Nominal Cooling
Capacity *1)
kcal/h
Btu/h
kW
Nominal Cooling
Capacity *2)
kcal/h
Btu/h
kW
Nominal Heating
Capacity
kcal/h
Btu/h
dB
Dimensions H x W x D
mm
Net Weight
Refrigerant
Motor
RCI-1.0FSN2
RCI-1.5FSN2
RCI-2.0FSN2
RCI-2.5FSN2
RCI-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
2.9
2,500
9,900
4.1
3,550
14,100
5.8
5,000
19,800
7.3
6,300
25,000
2.8
2,400
9,600
3.2
2,800
10,900
4.0
3,400
13,600
4.8
4,100
16,400
5.6
4,800
19,100
6.3
5,400
21,500
7.1
6,100
24,200
8.5
7,300
29,000
30-28-27
23
m3
Net Weight
Approximate
Packing Measurement
mm
kg
m3
8.3
7,100
28,200
11.6
10,000
39,700
14.5
12,500
49,600
8.0
6,900
27,300
9.0
7,700
30,700
11.2
9,600
38,200
12.5
10,700
42,600
14.0
12,000
47,800
16.0
13,800
54,600
13/12/11
(459/424/388)
38-35-33
39-37-35
24
26
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
15/13.5/12
(530/477/424)
16/14/12
(565/494/424)
20/17/15
(706/600/530)
21/18/15
(741/635/530)
29
32/28/24
(1,130/989/847)
124
6.35 / 12.7
0.22
Model
Indoor Unit Power Supply
kW
Nominal Cooling
Capacity *1)
kcal/h
Nominal Cooling
Capacity *2)
kcal/h
Nominal Heating
Capacity
kcal/h
Btu/h
kW
Btu/h
kW
14
RCD-1.0FSN2
RCD-1.5FSN2
2.9
2,500
9,900
4.1
3,550
14,100
2.8
2,400
9,600
4.0
3,400
13,600
5.6
4,800
19,100
7.1
6,100
24,200
4.8
4,100
16,400
6.3
5,400
21,500
8.5
7,300
29,000
Btu/h
3.2
2,800
10,900
dB
34-32-30
Dimensions H x W x D
mm
Net Weight
Refrigerant
34/29/25
(1,201/1,024/883)
56
Condensate Drain
Approximate
Packing Measurement
RCI-5.0FSN2
32-30-28
W
mm
RCI-4.0FSN2
Connections
Liquid / Gas
General Data
kg
m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
298mm
Ceiling
35-32-30
Liquid / Gas
Approximate
Packing Measurement
P-N23WA
Silky White
37 x 950 x 950
6
Dimensions H x W x D
0.09
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.
11.6
10,000
39,700
14.5
12,500
49,600
8.0
6,900
27,300
11.2
9,600
38,200
14.0
12,000
47,800
9.0
7,700
30,700
12.5
10,700
42,600
16.0
13,800
54,600
40-36-33
43-40-36
48
13/11/9
(459/388/318)
35
mm
6.35 / 12.7
15/13/11
(530/459/388)
19/16/14
(671/565/494)
55
Flare-Nut Connection (With Flare Nuts)
6.35 / 15.88
9.53 / 15.88
Condensate Drain
0.26
RCD-5.0FSN2
38-34-31
27
Connections
9.53 / 15.88*3)
RCD-4.0FSN2
kg
m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor
RCD-2.0FSN2
RCD-2.5FSN2
RCD-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
5.8
7.3
8.3
5,000
6,300
7,100
19,800
25,000
28,200
29/24/21
(1,024/847/742)
34/29/25
(1,201/1,024/883)
35 x 2
55 x 2
9.53 / 15.88*3)
VP25
m3
0.23
0.37
P-N23DWA
P-N46DWA
Silky White
mm
30 x 1,100 x 710
30 x 1,660 x 710
Net Weight
kg
Approximate
Packing Measurement
m3
0.10
0.15
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meters Beneath the Unit.
Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.
Indoor Units
Indoor Units
In-the-ceiling Type
Ceiling Type
Minimum 5mm
270mm
(0.8HP ~ 2.5HP)
Less
15
False Ceiling
Weight 46kg
Weight 37kg
RPI-1.0FSN2
RPI-1.5FSN2
Nominal Cooling
Capacity *2)
Nominal Heating
Capacity
kW
kcal/h
Btu/h
kW
kcal/h
Btu/h
2.3
2,000
7,900
2.2
1,900
7,500
2.5
2,100
8,500
2.9
2,500
9,900
2.8
2,400
9,600
3.2
2,800
10,900
dB
Dimensions H x W x D
mm
270 x (650+75)
x 720
kg
26
Net Weight
Refrigerant
3
Air Flow Rate Hi/Me/Lo m /min.
(cfm)
External Pressure
Motor
W
Gas
Condensate Drain
Approximate
Packing Measurement
RPI-2.5FSN2
4.1
3,550
14,100
4.0
3,400
13,600
4.8
4,100
16,400
5.8
5,000
19,800
5.6
4,800
19,100
6.3
5,400
21,500
35-33-31
8/7/6
(283/247/212)
60
RPI-3.0FSN2
RPI-4.0FSN2
Heat Exchanger
RPI-5.0FSN2
7.3
6,300
25,000
7.1
6,100
24,200
8.5
7,300
29,000
8.3
7,100
28,200
8.0
6,900
27,300
9.0
7,700
30,700
11.6
10,000
39,700
11.2
9,600
38,200
12.5
10,700
42,600
14.5
12,500
49,600
14.0
12,000
47,800
16.0
13,800
54,600
36-34-32
42-39-35
43-40-36
44-41-37
270 x (900+75)
x 720
RPI-8FSN
RPI-10FSN
35
46
37
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
45(42)*
Downward
Flow
Horizontal
Flow
470 x 1,250
x 1,120
mm
6.35
mm
12.7
15.88
m3
0.21
9.53
15.88
VP25
15.88*5)
Model
Indoor Unit Power Supply
kW
Nominal Cooling
Capacity *1)
19.05*7)
22.2*8)
Nominal Cooling
Capacity *2)
0.38
0.52
1.060.37
1.06
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1.5 Meter Beneath the Unit. With Discharge Duct (2.0m) and Return Duct (1.0m).
0.8~5.0FSN2: Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2dB.
8 and 10FSN: Voltage of the power source for the indoor fan motor is 380V. In case of the power source of 415V, the sound pressure level increases by about 2dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. The values with ( )* of sound pressure level, air flow rate, external pressure and motor output indicate the values incase of external pressure setting at 110Pa (130Pa for 410V).
4. The data for external pressure *3) indicates "Standard Pressure Setting ( High Pressure Setting - Low Pressure Setting )" values when a filter is not used.
The data for external pressure *4) indicates the values when a filter is not used.
5. *5) In case of using R407C or R22, use the accessory adaptor and 19.05 piping. *6) In case of using R407C or R22, use the accessory reducer and 12.7 piping.
*7) In case of using R407C or R22, use the accessory reducer and 25.4 piping. *8) In case of using R407C or R22, use the accessory reducer and 28.6 piping.
kW
kcal/h
Btu/h
kW
Nominal Heating
Capacity
Sound Pressure Level
(Overall A Scale)
kcal/h
Btu/h
RPC-2.0FSN2
RPC-2.5FSN2
RPC-4.0FSN2
RPC-5.0FSN2
7.3
6,300
25,000
RPC-3.0FSN2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
8.3
7,100
28.200
5.8
5,000
19,800
11.6
10,000
39,700
14.5
12,500
49,600
5.6
4,800
19,100
7.1
6,100
24,200
8.0
6,900
27,300
11.2
9,600
38,200
14.0
12,000
47,800
6.3
5,400
21,500
8.5
7,300
29,000
9.0
7,700
30,700
12.5
10,700
42,600
16.0
13,800
54,600
dB
44-41-38
40-37-34
Silky White
Cabinet Color
Dimensions H x W x D
Net Weight
Refrigerant
mm
kg
26
30
34
42
m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor
0.29
kcal/h
Btu/h
100
58
290
General Data
52(50)*
16/14/12
58 (58)*
72 (72)*
19/17/14
37/31/25
13/11/9
15/13/11
27/23/19
(459/388/318) (530/459/388) (565/494/424) (671/600/494) (954/812/671) (1,306/1,095/883) (2,048 (2,048)*) (2,542 (2,542)*)
220 (110)* / 260 (130)* *4)
120 (170-60)*3)
50 (80-30)*3)
0.230.27
While
Stopped
AC 3
75
150
Flare-Nut Connection (With Flare Nuts)
6.35
9.53
Connections
Liquid
RPI-2.0FSN2
kW
kcal/h
Btu/h
Heat Exchanger
RPI-0.8FSN2
Nominal Cooling
Capacity *1)
Fan
Fan
Slimmer
General Data
Model
New Model
Current Model
Auto-louver
250mm
Width 650mm
Width 900mm
14/12/10
(494/424/353)
35
Connections
Liquid / Gas
mm
6.35 / 15.88
18/15/12
(636/530/424)
50
Flare-Nut Connection (With Flare Nuts)
9.53 / 15.88
Condensate Drain
Approximate
Packing Measurement
Standard Accessories
25/21/18
(883/742/636)
33/28/23
(1,165/989/812)
95
135
9.53 / 15.88*3)
VP20
m3
0.30
0.43
0.36
0.50
Mounting Bracket
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions. 1 Meter Beneath the Unit and 1 Meter from Discharge Grille.
Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1dB.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) In case of using R407C or R22, use the accessory adaptor and 19.05 piping.
16
Indoor Units
Indoor Units
Wall Type
Floor Type
Industry-leading Compactness
Flat Panel at The Front
1,390mm
New Model
25%
decreased
1,150mm
User Friendly
17
General Data
Model
Indoor Unit Power Supply
11.6
10,000
39,700
2.8
2,400
9,600
4.0
3,400
13,600
5.6
4,800
19,100
7.1
6,100
24,200
8.0
6,900
27,300
11.2
9,600
38,200
Btu/h
3.2
2,800
10,900
4.8
4,100
16,400
6.3
5,400
21,500
8.5
7,300
29,000
9.0
7,700
30,700
12.5
10,700
42,600
dB
38-36-34
40-38-36
41-39-37
kcal/h
kcal/h
Cabinet Color
Net Weight
Refrigerant
kg
m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
Motor
10/8/7
(353/283/247)
11/10/9
(388/353/318)
Standard Accessories
20
mm
6.35 / 12.7
14/12/10
(494/424/353)
18
17/16/14
(600/565/494)
0.07
0.11
Floor Type
Model
22/20/17
(777/706/600)
kW
4.1
3,550
14,100
4.0
3,400
13,600
2.9
2,500
9,900
2.8
2,400
9,600
4.1
3,550
14,100
4.0
3,400
13,600
Btu/h
3.2
2,800
10,900
4.8
4,100
16,400
3.2
2,800
10,900
4.8
4,100
16,400
dB
35-32-29
38-35-31
35-32-29
38-35-31
kcal/h
Nominal Cooling
Capacity *2)
kcal/h
Btu/h
kW
Btu/h
kW
Nominal Heating
Capacity
Sound Pressure Level
(Overall A Scale)
Net Weight
Refrigerant
kcal/h
0.13
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on the following conditions measured. 1 Meter Beneath the Unit and 1 Meter from Inlet Grille.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. *3) The refrigerant piping size may be required to change depending on the outdoor unit to be connected.
If 12.7 pipe is used at the gas side, remove the flare adaptor at the indoor unit gas piping. Then attach the flare nut (accessory) for pipe connection.
Spring White
mm
kg
25
m3/min.
Air Flow Rate Hi/Me/Lo (cfm)
W
8.5/7/6
(300/247/212)
20
Connections
Liquid / Gas
mm
Condensate Drain
Approximate
Packing Measurement
RPFI-1.5FSN2E
2.9
2,500
9,900
2.8
2,400
9,600
Nominal Cooling
Capacity *1)
Motor
9.53 / 15.88
RPFI-1.0FSN2E
RPF-1.5FSN2E
AC 1 , 220-240V / 50Hz, 220V / 60Hz
Dimensions H x W x D
18
VP16
m3
Cabinet Color
30
Condensate Drain
Approximate
Packing Measurement
49-46-43
12
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
Connections
Liquid / Gas
43-40-37
White
mm
RPF-1.0FSN2E
8.3
7,100
28,200
kW
Dimensions H x W x D
RPK-4.0FSNSM2
7.3
6,300
25,000
Btu/h
RPK-3.0FSNSM2
5.8
5,000
19,800
kW
Nominal Heating
Capacity
RPK-2.0FSNSM2
RPK-2.5FSNSM2
AC 1 , 220-240V / 50Hz, 220V / 60Hz
4.1
3,550
14,100
Btu/h
Nominal Cooling
Capacity *2)
RPK-1.5FSNSM2
2.9
2,500
9,900
kcal/h
General Data
RPK-1.0FSNSM2
kW
Nominal Cooling
Capacity *1)
m3
0.26
28
19
R410A / R407C / R22 (Nitrogen-Charged for Corrosion-Resistance)
12/10/9
(424/353/318)
8.5/7/6
(300/247/212)
28
20
Flare-Nut Connection (With Flare Nuts)
6.35 / 12.7
18.5 OD
0.29
0.20
23
12/10/9
(424/353/318)
28
0.23
NOTES:
1. The nominal cooling capacity is the combined capacity of the HITACHI standard split system, and is based on the JIS standard B8616.
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature: 27C DB (80F DB)
Indoor Air Inlet Temperature: 20C DB (68F DB)
*1)
19.5C WB (67F WB)
Outdoor Air Inlet Temperature: 7C DB (45F DB)
*2)
19.0C WB (66.2F WB)
6C WB (43F WB)
Outdoor Air Inlet Temperature: 35C DB (95F DB)
Piping Length: 7.5 Meters
Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
Floor Type: 1.5 Meters from the Unit and 1.5 Meters from Floor Level. Floor Concealed Type: 1.5 Meters from the Unit and 1.5 Meters from the Floor Level.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
System Equipment
Remote Controllers
Individual Control
Controllable Using the Remote Control Switch
for The Air Conditioning Unit
3
H-LINK
Example
of
System
SET-FREE
PC-AR
Component of
System
5
H-LINK
CSNET
PC-AR
Outlook of
System
H-LINK
H-LINK
CSNET
PC-AR
General Data
Model
KPI-2521
KPI-5021
KPI-8021
KPI-10021
50Hz
m /h
250/250/165
500/500/350
800/800/670
1,000/1,000/870
High/Med/Low
60Hz
m3/h
250/250/150
500/500/300
800/800/660
1,000/1,000/720
50Hz
Pa
65/40/20
150/60/30
140/100/70
160/100/80
High/Med/Low
60Hz
Pa
100/50/20
200/60/20
230/120/80
200/110/60
50Hz
dB
26.5-27.5/25-26/21-22
32.5-33.5/30-31/23.5-24.5
33.5-34.5/32-33/30-31
36-37/34-35/31.5-32.5
60Hz
dB
28.5/25.5/21
32.5/28.5/23
35/31/29
36/34/30
mm
Net Weight
kg
21
33
61
72
Approximate Packing
Measurement
m3
0.26
0.46
0.70
0.84
NOTES:
*1. Use it under the following conditions. KPI-8021: 29Pa or more, KPI-10021: 49Pa or more
*2. The sound pressure level is based on following conditions.
1.5 Meter beneath the unit and this data was measured in an anechoic chamber so that reflected sound should be taken into
consideration in the field.
*3. The sound pressure level is based on the total heat exchange mode.
In case of the bypass ventilation mode, the sound pressure level is incrased by approximately 1dB(A).
CSNET
PC-AR
Component of
System
PC-ARH
Example
of
System
Large LCD
PSC-5S
PSC-A64S
PC-AR
T.H.E+PC-AR
Outlook of
System
PC-AR
UTOPIA
PC-AR
19
:Total Heat
Exchanger (T.H.E)
:Indoor Unit
PC-AR
Centralized Control
PSC-5S
PSC-A64S Central Station
By connecting to H-LINK, a group of up to
16(PSC-5S) and 64(PSC-A64S) remote controls
can be used and up to 128 indoor units can be
controlled.
Up to 8 units can be connected to H-LINK.
In addition to the basic functions, the operation
mode and temperature setting,
air quantity or auto louver can be set.
20
CS-NET
CS-NET Features
Control Function
Monitoring Function
On/Off Control
On/Off Control
Operation Mode
Temperature Setting
Set Temperature
Filter Sign
PCB
ID=7
Alarm Code
2
LONWORKS *
R
HARC 40
P/C
H-LINK
HARC70-P1 *3
PCB
PCB
PCB
PCB
fri
ge
ra
nt
Pi
pe
R
e
System Example
Interface
Outdoor Unit
LONWORKS
Transmission Line
H-LINK
Refrigerant Pipe
HARC-BX*4
Indoor Unit
CS-NET
Remote Controllers
Option
22
By using the HARC-BX or HARC70-P1 adapter for LONWORKS to connect air conditioners to
the total building control system, air conditioners can be centrally controlled.
H-LINK is a system to connect the control wires for outdoor and indoor units
across two or more refrigerant cycles. Regardless of the branching of
wirings, all the units can be controlled, thus total costs can be reduced.
INK
H-L
PCB
H-LINK System
21
HARC 40*3
ID=0 (Option)
Alarm
H-LINK*2
USB Hub
(Field supply)
CS-NET
Optional Parts
Interface (Option)
Indoor Units
HP
HARC 40
Air Panel
Specifications
Connection Method to
Upper System
Control Item at
Upper System
Monitiring Item at
Upper System
On / Off Control
Air Direction Setting Fan Speed Setting
Operation Mode Setting Remote Control Fully Filter Sign Resetting
Temperature Setting
Air Direction Setting
Allowed/Prohibited
[Cooling :19C ~ 30C
Remote Control Partially (Cannot be set by
Allowed/Prohibited
Heating : 17C ~ 30C]
wireless remote control)
On / Off
Operation Mode
Set Fan Speed
Set Air Direction
Set Temperature
Remote Control
Prohibition Setting
Filter Sign
Alarm
Alarm Code
Air Inlet Temperature
HARC70-P1
Connection Method to
Upper System
PI-23LS5
F-23L4-D
Deodorant Filter
F-46L4-D
Filter Box
B-23H4
F-23L4-KS
F-23L4-K
1
Fresh Air Intake Kit *
OACI-232
2
T-Pipe Connection Kit *
TKCI-232
Duct Adapter
*3
PD-75 ( 75)
1.0 ~ 3.0
HP
Air Panel
P-N46DWA
P-N23DWA
PC-ALH
23
3.0 ~ 5.0
P-N23WA
PC-ALHD
Control Item at
Upper System
On/Off Order
Operation Mode Setting
Temperature Setting
All On/Off Order
Monitiring Item at
Upper System
Temperature Setting
Individual Thermostat State
24
Deodorant Filter
F-23LD4-D
F-46LD4-D
B-23HD4
B-46HD4
F-23LD4-K
F-46LD4-K
1
Fresh Air Intake Kit *
OACID-231
Filter Box
OACID-461
HARC-BX
In-the-ceiling Type
Specifications
HARC-BX E (Standard)
Connection Method to
Upper System
TBCID-1
HP
0.8 ~ 1.5
3.0
4.0
5.0
Long-Life Filter
F-15LI3C
F-23LI3C
F-23LI3
F-34LI3
F-46LI3
Filter Box
B-15MI3C
B-23MI3C
B-23MI3
B-34MI3
B-46MI3
Standard
DUPI-132C
On/Off Order
Operation Mode Setting
Temperature Setting
All On/Off Order
Monitiring Item at
Upper System
Temperature Setting
Individual Thermostat State
DUPI-162
PC-ALHZ
HARC-BX E (Option A)
A HARC-BX can connect to multiple
H-LINK with H-LINK transmission
terminal to 8 PCB.
Points for control and monitor have
been increased to meet more points.
(Points for control and monitor is 8
times larger than HARC70P-1.)
You can select the number of
controls, monitor, and what to control
in the indoor unit from three choices
(Standard, Option A and Option B)
as needed.
Connection Method to
Upper System
Control Item at
Upper System
On/Off Order
Operation Mode Setting
Temperature Setting
Monitiring Item at
Upper System
HARC-BX E (Option B)
Connection Method to
Upper System
On/Off Order
Operation Mode Setting
Temperature Setting
On/Off State & Alarm
Operation Mode State
Fan Speed Setting
HP
RPF(I)
1.0 and 1.5
RPC
2.0 ~ 5.0
PC-ALHZ
PC-ALHP
NOTES:
*1: It is necessary to use the Fresh Air Intake Kit to connect the fresh air intake duct to the unit.
*2: Used when two air intakes( 100 x 2)of the Fresh Air Intake Kit is changed to one air intake ( 150 x 1).
*3: Used when fresh air intake duct are connected to the indoor unit directly.
*4: Used when both of the Fresh Air Intake Kit and Filter Box are used.
DU-M280PIS
Optional Parts
Multi-kits
Applicable Outdoor Unit
RAS-5FSN
RAS-8FSN1
RAS-10FSN1
RAS-12FSN1
RAS-14FSN1
RAS-16FSN1
RAS-18FSN1
RAS-20FSN1
RAS-22FSN1
RAS-24FSN1
RAS-26FSN1
RAS-28FSN1
RAS-30FSN1
RAS-32FSN1
First Branch
Line Branch
First Branch
or
Last Branch
RAS-34FSN
RAS-36FSN
RAS-38FSN
RAS-40FSN
RAS-42FSN
MW-302AN
(E-302SN)
MW-162AN
(E-162SN)
MW-102AN
(E-102SN)
Project Name:
Consultant:
Contractor:
Delivery Date:
System Layout:
MW-242AN
(E-242SN)
MH-84AN
(E-84HSN)
4 Distributions
for 5~8 HP
Header Branch
(First Branch, Last Branch)
MH-108AN
(E-108HSN)
8 Distributions
for 5~10 HP
26
25
Control System
RCIFSN2
Remote Control Switch
Wireless Remote
Control Switch
PC-LH3A
Half-size Remote
Control Switch
PC-ARH*2
7-Day Timer
PSC-A1T
Central Station
PSC-5S, PSC-A64S*3
Remote Control
Cable
PRC-5K,10K,15Kfor PC-AR
3P Connector Cable
PCC-1A
Remote Sensor
THM-R2A
P/C Network
System CS-NET
PSC-6WTX
: Applicable
: Not Applicable
RCDFSN2
RPIFSN(2)
RPCFSN2
NOTES:
*1: As the PC-AR does not include a remote control cable, prepare one in the field, or use PRC-5K, 10K, or 15K.
*2: Make sure that it is used with PC-AR or CS-NET.
*3: Supply 220V or 240V.
RPKFSNSM2
RPF(I)FSN2E
KPI