MS8C/MS8H
Lennox 8 Series
P R O D U C T S P E C I F I C AT I O N S
Wireless
Remote Control
(furnished)
SEER up to 22.00
0.75 to 2.5 Tons
Cooling Capacity - 9,000 to 28,000 Btuh
Heat Pump Heating Capacity - 9,500 to 28,400 Btuh
MS 8 - CO - 12 P 1 A
Minor Revision
Series Type
MS = Mini-Split
Number of Zones
1 = One Zone
Voltage
L = 115V-1phase-60hz
P = 208/230V-1phase-60hz
Major Revision
Unit Type
CO = Air Conditioner Outdoor Unit
HO = Heat Pump Outdoor Unit
INDOOR UNITS
MS 8 - CI - 12 P 1 A
Series Type
MS = Mini-Split
Major Revision
Unit Type
CI = Air Conditioner Indoor Unit
HI = Heat Pump Indoor Unit
Minor Revision
Number of Zones
1 = One Zone
Voltage
L = 115V-1phase-60hz
P = 208/230V-1phase-60hz
Nominal Cooling Capacity
09 = 0.75 tons
12 = 1 tons
18 = 1.5 tons
24 = 2 tons
30 = 2.5 tons
EQUIPMENT WARRANTY
Compressor - limited warranty for five years in
residential installations and one year in non-residential
installations.
All other covered components - five years in
residential installations and one year in non-residential
installations.
Refer to Lennox Equipment Limited Warranty certificate
included with unit for specific details.
APPLICATIONS
SEER up to 22.00.
HSPF (Heat Pumps) up to 10.20.
0.75 through 2.5 ton.
Single phase power supply (115V and 208/230V).
Outdoor unit sound levels as low as 63 dB.
Ductless mini-split systems provide a wide range of
capacities and applications and provide an alternative
when a ducted system is impractical or cost prohibitive.
See AHRI System Matches.
Units shipped completely factory assembled, internally
piped, and wired.
Installer must set outdoor unit, hang indoor unit, connect
refrigerant lines, and make electrical connections to
complete job.
APPROVALS
AHRI Certified to AHRI Standard 210/240-2008.
Tested in the Lennox Research Laboratory
environmental test room.
Rated according to U.S. Department of Energy (DOE)
test procedures.
Indoor and outdoor units and components within
bonded for grounding to meet safety standards for
servicing required by UL and CEC.
Units are ETL certified for the U.S. and Canada.
POWER
Turns system on and off. Also overrides SLEEP
function.
MODE
Select system operation modes (AUTO/COOL/
DEHUMIDIFICATION/FAN/HEAT). Default setting is
AUTO.
/- (Plus/Minus) BUTTONS
+
Increase or decrease temperature in one degree
increments.
NOTE - Temperature cannot be adjusted in AUTO
mode.
AN
F
Select fan speed (AUTO/LOW/MEDIUM/HIGH). Default
setting is AUTO. Fan speed is displayed at the top of
the control display.
NOTE - Not adjustable during Dehumidification mode.
I FEEL
Allows remote temperature sensing of the room at the
remote control location.
LOUVER SETTING
Sets the angle of the horizontal louvers. Four oscillating
settings and five fixed position settings. Full oscillating is
the default setting when button is first pushed.
OFF
Optional Accessories
TEMP
Set temperature and display current indoor ambient
temperature.
INDOOR UNITS
Condensate Mini-Split Drain Line
Constructed of flexible reinforced polypropylene,160 ft.
roll.
Condensate Pump
Quietly and efficiently removes condensate.
Designed to be installed above a false ceiling, behind
wall-mounted evaporators or in plastic conduit.
ETL listed.
SPEEDICHANNEL SYSTEM
Fuses
30 and 60 amp fuses available.
Indoor/Outdoor Wiring Cable
(09 through 24 models only)
14-gauge, 4-conductor wire. THHN (Thermoplastic High
Heat-resistant Nylon-coated) wire. Suitable for wet or
dry locations. Rated up to 600V.
Refrigerant Line Sets
Refrigerant lines are shipped refrigeration clean. Lines
are cleaned, dried, pressurized and sealed at factory.
Wall Brackets
Heavy duty 1/8 in. thick steel brackets for supporting
outdoor units. Mount at any height to allow for easy
maintenance under units. Pre-punched holes for easy
installation. Powder coated gray finish. Load rating 600
lbs. per pair.
Whips
Heavy duty electrical whips are available in 8 and 10
gauge sizes. 6 ft. lengths. Weatherproof metal conduit.
Universal Mini-Split Installation Kit
Wall
Penetration
Cover
SpeediChannel
90 Flat
Bend
SpeediChannel
Union
Coupling
SpeediChannel
Outdoor
Unit
Duct End
Duct End
Duct Ends are used
to terminate a run of
SpeediChannel to a small
opening just large enough for
the line set and condensate
drain line to pass through.
Flex Joint
A Flex Joint is an accordion-style piece of
SpeediChannel. The flex joint can be extremely
flexible when routing a SpeediChannel system
around an obstacle. Each joint is 20 in. long and can
be combined together for longer flex runs. The flex joint
does not require the use of a union coupling. The flex
joint slides tightly inside the SpeediChannel system.
90 Inside Elbow
90 Inside Elbows are used to route the
SpeediChannel around an inside corner. Each elbow
is individually packed and furnished with stainless steel
screws.
T-Joint
T-Joints are used for creating a tee
connection between three pieces
of SpeediChannel. Each tee is
individually packed and furnished with
stainless steel screws.
Union Coupling
Union Couplings are used for joining
two pieces of SpeediChannel. Each coupling is
individually packed and furnished with stainless steel
screws.
45
90
OUTDOOR UNIT
0.75
0.75
1
1
1.5
2
MS8-CO-09L MS8-CO-09P MS8-CO-12L MS8-CO-12P MS8-CO-18P MS8-CO-24P
9,600
3,500
3,500
3,100
3,100
5,970
21,400
9,000
9,000
12,000
12,000
18,000
25,000
9,600
9,600
13,000
13,000
22,350
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
3/8
1/2
5/8
41 - 115
0 - 109
41 - 115
0 - 109
5 - 109
5 - 109
2 lbs. 6 oz. 2 lbs. 14 oz. 2 lbs. 14 oz. 2 lbs. 14 oz. 3 lbs. 1 oz.
3 lbs. 9 oz.
3.95
4.08
4.08
4.49
5.96
7.66
1/4
1/4
3/8
3/8
1/4
1/4
2
2
2
2
2
2
18
20
18
20
20
20
15-5/8
15-3/4
15-5/8
15-3/4
20-1/2
21-3/4
3
3
3
3
3
3
1120
940
1120
940
1885
2355
650/900
680/900
680/900
680/900
800
800
91
91
97
97
110
132
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph
Maximum overcurrent protection (amps)
3
Minimum circuit ampacity
Compressor
Rated load amps
4
Compressor Power Input (W)
Outdoor
Rated load amps
Fan Motor
Output (W)
2
115V
208/230V
115V
208/230V
208/230V
208/230V
35
15
40
15
20
25
22
10
23
10
13
16
16
7.2
17.5
6.5
9.7
11
1050
1075
1450
860
1200
1420
0.17
0.13
0.17
0.13
0.28
1.1
40
40
40
30
60
90
MATCHING INDOOR UNIT
MS8-CI-09L MS8-CI-09P MS8-CI-12L MS8-CI-12P MS8-CI-18P MS8-CI-24P
1/4
1/4
1/4
1/4
1/4
1/4
3/8
3/8
3/8
3/8
1/2
5/8
330
305
300
335
500
590
295
275
275
275
460
470
255
255
255
255
385
410
220
220
215
220
325
355
1260
1260
1260
1330
1500
1500
1050
1100
1070
1100
1200
1200
920
950
900
950
1050
1050
730
750
730
750
900
900
1.85
1.65
1.85
1.65
2.33
3.23
1/4
1/4
1/4
1/4
1/4
1/4
2
2
2
2
2
2
18
20
18
20
20
18
3.6 x 25.4
3.6 x 25.4
3.6 x 25.4
3.6 x 25.4
3.9 x 28
3.9 x 30
Cross-flow
Cross-flow
Cross-flow
Cross-flow
Cross-flow
Cross-flow
31
31
31
29
38
47
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph
Rated Load Amps
Output (W)
115V
0.38
20
208/230V
0.20
20
115V
0.38
20
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. of lineset.
2
HACR type circuit breaker or fuse
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Rated Input
208/230V
0.20
20
208/230V
0.32
20
208/230V
0.24
60
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph
Max. overcurrent protection (amps)
3
Minimum circuit ampacity
Compressor
Rated load amps
4
Compressor Power Input (W)
Outdoor
Rated load amps
Fan Motor
Output (W)
208/230V
115V
208/230V
15
40
15
10
23
10
7.2
17.5
6.5
860
1200
860
0.13
0.17
0.13
30
40
30
MATCHING INDOOR UNIT
Indoor Unit Model No. MS8-HI-09L MS8-HI-09P MS8-HI-12L MS8-HI-12P
Connections Small line o.d. - flare
1/4
1/4
1/4
1/4
(in.)
Large line o.d. - flare
3/8
3/8
3/8
3/8
Indoor Blower
Turbo
330
306
300
335
Air Volume
High
295
277
275
277
(cfm)
Medium
255
253
255
253
Low
220
218
215
218
Indoor Blower
Turbo 1260/1320 1260/1320 1260/1280 1330/1350
RPM
High 1050/1200 1100/1200 1070/1050 1100/1170
(Cooling/Heating)
Medium 920/1100
950/1100
900/980
950/1050
Low
730/950
750/950
730/920
750/950
Indoor
Net face area - sq. ft.
1.85
1.65
1.85
1.65
Coil
Tube diameter - in.
1/4
1/4
1/4
1/4
Number of rows
2
2
2
2
Fins per inch
18
20
18
20
Indoor
Diameter x Length - in. 3.6 x 25.4
3.6 x 25.4
3.6 x 25.4
3.6 x 25.4
Blower
Type Cross-flow Cross-flow Cross-flow Cross-flow
Shipping Data - lbs.
Indoor Unit
37
37
37
37
2
115V
35
22
16
600
0.17
40
208/230V
20
13
9.7
1200
0.28
60
208/230V
25
16
11
1420
1.1
90
208/230V
30
20
13.5
2450
0.45
90
MS8-HI-18P
1/4
1/2
500
459
383
324
1500/1500
1200/1250
1050/1150
900/1050
2.33
1/4
2
20
3.9 x 28
Cross-flow
38
MS8-HI-24P
1/4
5/8
590
470
410
355
1500/1450
1200/1150
1050/1020
900/950
3.23
1/4
2
18
3.9 x 30
Cross-flow
47
MS8-HI-30P
1/4
5/8
--705
675
645
--1410/1410
1280/1280
1200/1200
14.8
1/4
2
18
4.25 x 20.5
Cross-flow
60
208/230V
0.32
20
208/230V
0.24
60
208/230V
0.40
40
ELECTRICAL DATA
Line voltage data - 60 hz - 1ph
Rated Load Amps
Output (W)
115V
0.38
20
208/230V
0.20
20
115V
0.38
20
208/230V
0.20
20
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. of lineset.
2
HACR type circuit breaker or fuse
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Rated Input
Catalog
No.
09
12
18
24
30
48X92
30 amp, fused, 1 ph
27P37
60 amp, non-fused, 1 ph
27P39
30A
83P75
60A
83P77
X0258
90X52
X0259
90X51
X0260
Y0576
30 inch
Y5020
36 inch
Y5021
29P54
27P44
Condensate Pump - ClearVue Mini - 7.9 US gallons per hour, 35 ft. lift - 120/240V
Y5170
Y3401
Y2067
Y5073
Y3247
Y3387
Y3388
Y3389
Y3390
Y3391
Y3392
Y3393
T-Joint - 4 in.
Y3394
Y3395
Y3396
Y3399
Y3397
Y3398
Description
OUTDOOR UNIT
Condenser Pad (18 x 36 x 2)
Disconnects
Fuses
Line Sets
INDOOR UNIT
INSTALLATION KIT
Universal Mini-Split Installation Kit
SPEEDICHANNEL SYSTEM
Capacity
SEER
EER
Indoor Model
AHRI
Reference
MS8-CO-09L
9000
22.00
14.20
MS8-CI-09L
5625426
MS8-CO-09P
9000
22.00
14.20
MS8-CI-09P
5625428
MS8-CO-12L
12,000
20.00
12.50
MS8-CI-12L
5625427
MS8-CO-12P
12,000
20.00
12.00
MS8-CI-12P
5625429
MS8-CO-18P
18,000
18.00
12.00
MS8-CI-18P
5625430
MS8-CO-24P
21,400
18.00
12.00
MS8-CI-24P
5625431
NOTE:
Ratings are AHRI certified to AHRI Standard 210/240; 95F outdoor air temperature, 80F db / 67F wb entering evaporator air.
HSPF
High
Low
Region IV
14.20
9500
5400
9.80
MS8-HI-09L
5625419
14.20
9800
5500
9.20
MS8-HI-09P
5625421
20.00
12.50
12,100 7500
9.60
MS8-HI-12L
5625420
12,000
20.00
12.00
13,000 7600
9.20
MS8-HI-12P
5625422
18,000
18.00
12.00
MS8-HI-18P
5625423
MS8-HO-24P
21,400
18.00
12.00
MS8-HI-24P
5625424
MS8-HO-30P
28,000
16.00
9.30
MS8-HI-30P
5625425
Outdoor Model
Capacity
SEER
EER
MS8-HO-09L
9000
22.00
MS8-HO-09P
9000
22.00
MS8-HO-12L
12,000
MS8-HO-12P
MS8-HO-18P
Indoor Model
AHRI
Reference
NOTES:
Ratings are AHRI certified to AHRI Standard 210/240;
Cooling Ratings - 95F outdoor air temperature and 80 F db/67 F wb entering indoor coil air.
High Temperature Heating Ratings - 47 F db/43 F wb outdoor air temperature and 70 F db entering indoor coil air.
Low Temperature Heating Ratings - 17 F db/15 F wb outdoor air temperature and 70 F db entering indoor coil air.
To convert HSPF from Region IV to Region V - Divide by 1.15.
12
18
24
30
Low Speed
18
19
25
23
N/A
Medium Speed
20
21
30
27
N/A
High Speed
23
25
32
30
N/A
Turbo Speed
N/A
N/A
35
37
N/A
Air
Conditioner
Heat Pump
Outdoor Unit
Model No.
MS8-CI-09L
MS8-CO-09P
MS8-CO-12L
MS8-CO-12P
MS8-CO-18P
MS8-CO-24P
MS8-HO-09L
MS8-HO-09P
MS8-HO-12L
MS8-HO-12P
MS8-HO-18P
MS8-HO-24P
MS8-HO-30P
Sound Rating
Number (dBA)
Pressure
Power
53
63
50
60
55
65
52
62
55
65
56
66
53
63
50
60
55
65
52
62
55
65
56
66
62
72
Indoor Unit
Model No.
Electrical
Connections
Cover
A
Refrigerant Line
Connections
Cover
Front View
Side View
Bottom View
Model No.
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
-09
21-1/4
540
30
762
12-5/8
320
10
254
11-1/4
286
21-1/4
540
33-3/8
848
-12
23-1/4
591
30
762
12-5/8
320
10
254
11-1/4
286
21-1/4
540
33-3/8
848
-18
27-5/8
702
35
890
15-5/8
397
13-3/8
340
14-1/2
368
22
560
37-1/2
955
-24, -30
31-1/8
790
36
914
16-7/8
427
14-5/8
371
15-3/4
399
24
610
38-5/8
981
Front View
Side View
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
-09
10-7/8
275
33-3/8
848
180
5-1/8
130
21-3/8
542
6-7/8
175
-12
10-7/8
275
33-3/8
848
180
5-1/8
130
21-3/8
542
6-7/8
175
-18
11-3/4
298
37
940
203
51
27
685
203
-24
12-3/8
315
39-3/4
1008
8-5/8
219
5-1/2
140
27
685
7-1/4
184
-30
12-7/8
326
53-1/8
1349
10
253
10
253
29-3/8
746
13-7/8
351
In.
mm
Left Side
12
305
Right Side
12
305
Front
48
1219
Rear
12
305
Top
24
510
INDOOR UNITS
In.
mm
Left Side
152
Right Side
152
Top
152
Bottom
72
1829
NOTES:
If outdoor unit is mounted on a flat rooftop allow a minimum of 4 in. (102 mm) above the roof surface.
Locate the unit above a load bearing wall or area of the roof that can adequately support the unit. Consult local
codes for rooftop applications.
REVISIONS
Sections
Description of Change
Optional Accessories
Visit us at www.lennox.com
For the latest technical information, www.lennoxdavenet.com
Contact us at 1-800-4-LENNOX
NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency.
2013 Lennox Industries, Inc.