Type C Boilers
G.C.N: 47-116-14
47-116-15
LEAVE THESE INSTRUCTIONS
WITH THE END-USER
Country of destination: GB
TABLE OF CONTENTS
1.
GENERAL INFORMATION
2.
INSTALLATION
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
REFERENCE STANDARDS
SITING THE APPLIANCE
OVERALL DIMENSIONS
CLEARANCES
MOUNTING THE APPLIANCE
ELECTRICAL CONNECTION
GAS CONNECTION
WATER CONNECTIONS
FLUE CONNECTION
ROOM THERMOSTAT CONNECTION
ELECTRICAL/SYSTEM DIAGRAMS
WATER CIRCUIT DIAGRAMS
3.
COMMISSIONING
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
3.9
INITIAL PREPARATION
CONTROL PANEL
REMOVING THE FRONT PANEL
INITIAL START UP
OPERATIONAL ADJUSTMENTS
COMBUSTION ANALYSIS
FUME DISCHARGE MONITORING
BOILER SAFETY SYSTEMS
DRAINING THE SYSTEM
4.
GAS ADJUSTMENTS
5.
MAINTENANCE
6.
MISCELLANEOUS
7.
TECHNICAL INFORMATION
1.
GENERAL
INFORMATION
This manual is an integral and essential part of the product. It should be kept
with the appliance so that it can be consulted by the user and our authorised
personnel.
Please carefully read the instructions
and notices about the unit contained in
this manual, as they provide important
infor mation regarding the safe
installation, use and maintenance of
the product.
For operating instructions please
consult the separate Users Manual.
CO034A
1.1
GENERAL INSTRUCTIONS
FIG. 1.0
1.2
OVERALL VIEW
LEGEND:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
IN013A
Flue connector
Air intake for twin pipe flue systems
Fan
Combustion chamber hood
Main heat exchanger
Safety thermostat
Combustion chamber
Combustion chamber insulation panel
Burner
Detection electrode
Ignition electrodes
Motorised diverter valve
Main circuit temperature probe
Main circuit flow switch
Domestic hot water temperature probe
Gas valve
Spark generator
Domestic hot water flow switch
Domestic cold water inlet filter
Secondary heat exchanger
Circulation pump with automatic air release valve
Safety valve (3 bar)
Expansion vessel
Air pressure switch
Combustion analysis intakes
2.
INSTALLATION
2.1
REFERENCE STANDARDS
BS 6891
1988
BS 6798
1987
BS 5449
1990
Flues
BS 5546
BS 5440-1
1990
1990
Air supply
BS 5440-2
1989
2.2
2.3
OVERALL DIMENSIONS
LEGEND:
A = Central Heating Flow (3/4)
B = Domestic Hot Water Outlet (1/2)
C = Gas Inlet (3/4)
D = Domestic Cold Water Inlet (1/2)
E = Central Heating Return (3/4)
2.4
CLEARANCES
FIG. 2.1
QT002A
2.5
2.7
ELECTRICAL CONNECTION
FIG. 2.2
DM004A
IMPORTANT!
FIG. 2.3
VR001A
marked L.
Note: The diagrams for the electrical system are indicated in section 2.11.
Warning, this appliance must be earthed.
External wiring to the appliance must be carried out by a qualified technician
and be in accordance with the current I.E.E. Regulations and applicable
local regulations. The Genus range of boilers are supplied for connection to
a 230 V~ 50 Hz supply.
The supply must be fused at 3 A.
The method of connection to the electricity supply must facilitate complete
electrical isolation of the appliance, by the use of a fused double pole
isolator having a contact separation of at least 3 mm in all poles or
alternatively, by means of a 3 A fused three pin plug and unswitched
shuttered socket outlet both complying with BS 1363.
The point of connection to the Electricity supply must be readily accessible
and adjacent to the appliance unless the appliance is installed in a bathroom
when this must be sited outside the bathroom.
2.8
GAS CONNECTION
2.9
WATER CONNECTIONS
The local gas region contractor connects the gas meter to the service pipe.
If the gas supply for the boiler serves other appliances ensure that an
adequate supply is available both to the boiler and the other appliances
when they are in use at the same time.
Pipe work must be of an adequate size. Pipes of a smaller size than the
boiler inlet connection should not be used.
FIG. 2.4
FIG. 2.5
KT002A
SC008A
LEGEND:
A
B
C
D
E
F
CENTRAL HEATING
Detailed recommendations are given in BS 6798:1987 and BS 5449-1:1990,
the following notes are given for general guidance.
7
PIPE WORK:
Copper tubing to BS EN 1057:1996 is recommended for water pipes.
Jointing should be either with capillary soldered or compression fittings.
Where possible pipes should have a gradient to ensure air is carried
naturally to air release points and water flows naturally to drain taps.
The appliance has a built-in automatic air release valve, however it should
be ensured as far as possible that the appliance heat exchanger is not a
natural collecting point for air.
Except where providing useful heat, pipes should be insulated to prevent
heat loss and avoid freezing.
Particular attention should be paid to pipes passing through ventilated
spaces in roofs and under floors.
BY-PASS:
The appliance includes an automatic by-pass valve, which protects the main
heat exchanger in case of reduced or interrupted water circulation through
the heating system, due to the closing of thermostatic valves or cock-type
valves within the system.
SYSTEM DESIGN:
This boiler is suitable only for sealed systems.
Drain Cocks:
These must be located in accessible positions to permit the draining of the
whole system. The taps must be at least 15mm nominal size and
manufactured in accordance with BS 2870:1980.
SAFETY VALVE DISCHARGE:
The discharge should terminate facing downward on the exterior of the
building in a position where discharging (possibly boiling water & steam) will
not create danger or nuisance, but in an easily visible position, and not
cause damage to electrical components and wiring.
The discharge must not be over an entrance or a window or any other type
of public access.
AIR RELEASE POINTS:
These must be fitted at all high points where air naturally collects and must
be sited to facilitate complete filling of the system.
The appliance has an integral sealed expansion vessel to accommodate the
increase of water value when the system is heated.
It can accept up to 6 l (1.3 gal) of expansion water. If the heating circuit has
an unusually high water content, calculate the total expansion and add an
additional sealed expansion vessel with adequate capacity.
MAINS WATER FEED - CENTRAL HEATING:
There must be no direct connection to the mains water supply even through
a non-return valve, without the approval of the Local Water Authority.
FILLING:
A temporary method for initially filling the system and replacing lost water
during servicing in accordance with Water Supply Byelaw 14 must be
provided.
DOMESTIC WATER
The domestic water must be in accordance with the relevant
recommendation of BS 5546:1990. Copper tubing to BS EN 1057:1996 is
recommended for water carrying pipe work and must be used for pipe work
carrying drinking water.
RESIDUAL HEAD OF THE BOILER
VR003A
2.9
FLUE SYSTEM
The provision for satisfactory flue termination must be made as described
in BS 5440-1.
The appliance must be installed so that the flue terminal is exposed to outdoor air.
The terminal must not discharge into another room or space such as an
outhouse or lean-to.
It is important that the position of the terminal allows a free passage of air
across it at all times.
The terminal should be located with due regard for the damage or
discolouration that might occur on buildings in the vicinity.
In cold or humid weather water vapour may condense on leaving the flue
terminal.
The effect of such steaming must be considered.
If the terminal is less than 2 metres above a balcony, above ground or above
a flat roof to which people have access, then a suitable terminal guard must
be fitted. When ordering a terminal guard, quote the appliance model
number.
A suitable terminal guard is available from:
TOWER FLUE COMPONENTS
Morley Road
Tonbridge
Kent TN9 1RA
The minimum acceptable spacing from the terminal to obstructions and
ventilation openings are specified in FIG. 2.6.
FLUE CONNECTIONS
BC
F
G
F D
HI
J
A
K
G
FIG. 2.6
TERMINAL POSTION
mm
300
75
200
200
75
300
300
600
1200
1200
1500
300
FU010A
60/100 mm
FU025A
FU002A
FIG. 2.7
9
FIG. 2.8
FU05A
80 mm
FIG. 2.9
FU004A
FU006A
IMPORTANT!
COAXIAL SYSTEMS
FIG. 2.10
FU001A
10
TABLE 2.1
23 MFFI
Exhaust
Type
Coaxial
Systems
60/100
Restrictor
43 mm
NO
Restrictor
Maximum
Extension
Exhaust/Air
L min = 0.5 m
L max = 2 m
L min = 2 m
L max = 4 m
L=4m
Restrictor
43 mm
NO
Restrictor
Maximum
Extension
Exhaust/Air
C12 (xx)
C32 (xx)
NONE
NONE
NONE
NONE
C42 (xx)
Exhaust
Type
43 m
C12 (xy)
C32 (xy)
Twin Pipe
Systems
80/80
L max = 11.5 m
C42 (xy)
C52 (xy)
L max = 11,4 m
L min = 11.5 m
43 m
L max = 43 m
43 m
L min = 11,4 m
40 m
4.3 m
6.9 m
4.3 m
6.9 m
NONE
5,7 m
NONE
21,7 m
L max = 40m
C82 (xy)
27 MFFI
Exhaust
Type
Coaxial
Systems
60/100
Restrictor
41 mm
NO Restrictor
L min = 0.5 m
L max = 1 m
L min = 1 m
L max = 4 m
Restrictor
41 mm
NO Restrictor
Maximum
Risk of Condensation Forming
Extension Piping not insulated
Piping insulated
Exhaust/Air 41 restrictor NO restrictor 41 restrictor NO restrictor
C12 (xx)
C32 (xx)
L=4m
NONE
NONE
NONE
NONE
C42 (xx)
Exhaust
Type
Maximum
Risk of Condensation Forming
Extension Piping not insulated
Piping insulated
Exhaust/Air 41 restrictor NO restrictor 41 restrictor NO restrictor
62 m
C12 (xy)
C32 (xy)
Twin Pipe
Systems
80/80
L max = 38 m
C42 (xy)
C52 (xy)
C82 (xy)
L max = 34 m
L min = 38 m
62 m
L max = 62 m
62 m
L min = 34 m
54 m
8m
11 m
19 m
31 m
8m
11 m
19 m
31 m
L max = 54 m
TWIN PIPE
SYSTEMS
FIG. 2.11
FU007A
A
Fo016A
12
Fo017A
ELECTRICAL DIAGRAM
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
LEGEND:
Colours:
Gry
=
Wh
=
Pnk
=
Brn
=
Bl
=
Blk
=
Rd/Blk =
Grey
White
Pink
Brown
Blue
Black
Red/Black
FIG. 2.12
Blk
Blk
Blk
Gry
Gry
Pnk
Pnk
Circulation Pump
Fan
Spark Generator/Gas Valve Supply
Motorised Diverter Valve
Flame Detection Circuit
Detection Electrode
Main Circuit Temperature Probe
Domestic Hot Water Temperature Probe
Domestic Hot Water Flow Switch
Main Circuit Flow Switch
Modulator
Air Pressure Switch
Safety Thermostat
External (Room) Thermostat
Rd/Blk
Brn
Brn
Brn
Wh
Wh
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Brn
Wh
Rd/Blk
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
V
U
Wh
Wh
Blk
Blk
=
=
Blk
Blk
Gry
Gry
Rd/Blk
Wh
Pnk
A
B
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Wh
2.12
SE017A
13
FIG. 2.13
L
M
SF014A
2.13
FIG. 2.14
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
Fan
Main Heat Exchanger
Overheat Thermostat
Burner
Ignition Electrodes
Detection Electrode
Motorised Valve
Main Circuit Temperature Probe
Main Circuit Flow Switch
Automatic By-pass
Domestic Hot Water Temperature Probe
Secondary Heat Exchanger
Gas Valve
Domestic Hot Water Flow Switch
Domestic Water Inlet Filter
Pressure Gauge
Safety Valve
Circulation Pump with Automatic
Air Release Valve
19. Expansion Vessel
20. Air Pressure Switch
SI017A
14
A.
B.
C.
D.
E.
3.
COMMISSIONING
3.1
INITIAL PREPARATION
3.2
CONTROL PANEL
LEGEND:
3.3
FR025A
A - On/Off knob
B - Domestic hot water temperature adjustment knob
C - Central heating selection (winter) and temperature
adjustment knob
D - On/Off L.E.D. (green)
E - Fume sensor L.E.D. (yellow)
F - Ignition failure (lockout) L.E.D. (red)
G - Economy/Comfort mode selection knob
H - Ignition failure (lockout) and/or overheat reset button
I - Overheat L.E.D. (red)
J - Low system water level L.E.D. (red)
K - Central heating temperature L.E.D (yellow)
L - Time clock
M - Heating system pressure gauge
FIG. 3.1
REMOVING THE
FRONT PANEL
A
4
FO006A
FO009A
FO012A
FO008A
FO013A
16
3.5
OPERATIONAL
ADJUSTMENTS
17
3.6
COMBUSTION ANALYSIS
3.7
FUME DISCHARGE
MONITORING
In the boiler, it is possible to monitor the correct operation of
the flue exhaust/air intake, checking for a loss of general
pressure in the system. Through the use of a differential
manometer connected to the test points of the combustion
chamber, it is possible to detect the P of operation of the air
pressure switch.
The value detected should not be less than 0,55 mbar for
23kW and 0.75 mbar for 27kW under conditions of maximum
thermal power in order for the boiler to function properly and
without interruption.
FU009A
3.8
The boiler is fitted with the following devices (see section 3.2 for references).
1 - IGNITION FAILURE:
This control signals an ignition failure on the burner 7 seconds after a
lighting failure. The L.E.D. F will illuminate to signal the shutdown
status.
The system can be reset by pressing and releasing the button H after
checking to make sure that the gas cock is open.
2 - CIRCULATION FAILURE:
This control signals that the safety pressure switch on the primary
circuit has not sensed a pressure of at least 1 bar within 40 seconds of
the activation of the circulation pump; the circulation pump comes to a
halt and the red L.E.D. J illuminates.
The system may be reset, after re-establishing the correct level of
pressure in the boiler, turning the A knob.
3 - OVERHEATING:
This control shuts off the boiler in the case where the primary circuit
reaches a temperature in excess of 105C.
The red L.E.D.s I and F will illuminate to signal this shutdown
status.
The system can be reset by waiting a few minutes for the primary
exchanger to cool down and then by pressing and releasing the H
button.
4. LIMESCALE BUILD-UP:
The boiler is equipped with a device that limits the formation of
Limescale in the secondary exchanger by controlling the temperature of
the domestic hot water (max 61C) and also controlling the temperature
of the water in the primary heating circuit.
18
5. ANTI-FROST DEVICE:
The boiler is equipped with a device that, in the event of the water
temperature going below 5C, the 3-way diverter valve switches to
domestic hot water and the burner ignites at the minimum power until
the boiler water reaches a temperature of about 50C.
This device operates only if the boiler is functioning perfectly and:
- the system pressure is sufficient;
- the boiler is powered electrically;
- the gas is distributed.
6 - EXHAUST DISCHARGE ANOMALY SHUTDOWN:
The boiler is fitted with safety devices, which in the event of defective
discharge of exhaust fumes, automatically interrupts the gas supply,
thereby shutting off the boiler.
The shutdown of the boiler is temporary and is indicated by the
illumination of the yellow L.E.D. E for a period of about 15 minutes.
Once this time period has passed and the discharge state of exhaust
fumes has returned to normal, the boiler automatically turns back on.
7 - SAFETY SHUTDOWN:
At the start of every lighting phase, the P.C.B. performs a series of
internal controls. If a malfunction occurs, the boiler will shutdown until
the problem has been resolved.
3.9
19
4.
GAS ADJUSTMENTS
Methane Gas
G20
MJ/m3h
mbar
mbar
45.67
20
17
80.58
29
20
80.58
37
25
mm
mc/h
Kg/h
1.30
2.72
----
0.77
---2.02
0.77
---2.02
mbar
11.0 - 2.0
(*) - 6.0
(*) - 6.0
mc/h
Kg/h
1.30
3.15
----
0.77
---2.34
0.77
---2.31
mbar
11.0 - 1.6
(*) - 4.6
(*) - 6.0
CATEGORY II2H3+
23 MFFI
Main Burner: n. 13 jets ()
Consumption (15C; 1013mbar)
Consumption (15C; 1013mbar)
Gas Cock Outlet Pressure
max - min
27 MFFI
Main Burner: n. 15 jets ()
Consumption (15C; 1013mbar)
Consumption (15C; 1013mbar)
Gas Cock Outlet Pressure:
max - min
The outlet pressure of the gas cock is obtained by completely loosening the
screw on the solenoid. The maximum pressure of the gas to the burner will
be equal to the nominal delivery pressure minus the head loss within the
gas valve.
4.1
The boiler can be converted to use either methane (natural) gas (G20)
or LPG (G30 - G31) by an Authorised Service Centre.
The operations that must be performed are the following:
1. Replace the jets on the main burner (see table in section 4);
2. Adjust the maximum and minimum thermal capacity values for the boiler
(see table in section 4);
3. Replace the gas rating plate;
4. Adjust the maximum thermal power setting;
5. Adjust the soft-light feature;
6. Adjust the ignition delay feature for the heating system (can be set from 0
to 2 mins.).
CHANGING THE
TYPE OF GAS
CATEGORY II2H3+
20
Methane
Gas
G20
Liquid
Butane
Gas
G30
Liquid
Propane
Gas
G31
8.0
16.0
16.0
5.
MAINTENANCE
21
240V
MAINS INPUT (3 AMP)
2
2
T6360B
ROOM
THERMOSTAT
ZONE 2
22
8
ZONE 2
Randall 3020 P
and 3060
HTG
ON
ZONE 1
PROGRAMMER
E
E
ZONE 1
10
10
Towerchron MP
Link 1-4/6-11
Towerchron FP
Link 1-5/4-7-9
4
3
HW
ON
Towerchron 2000
7
6
Sunvic ET 1451
Link 2-3-6
BOILER
PROGRAMMER
Switchmaster
Symphony, Sonata
ZONE 2
Randall 102/102 E
Link 3-6
Potterton Miniminder
Randall 4033
Link 1-6
3
3
10
3
3
9
6
E
GREEN/YELLOW
7
10
ORANGE
GREY
6
BLUE
BROWN
Drayton Tempus 7
2
microGENUS 23-27 MFFI
3
TYPICAL
JUNCTION BOX
4
3
Pegler Sunvic
SP 50/100 (Link L-3)
V4043H
VALVE
10
GREEN/YELLOW
9
10
ORANGE
T6360B
ROOM
THERMOSTAT
2
GREY
ZONE1
4
BLUE
V4043H
VALVE
1
BROWN
Sangamo M5
Link 1-6
7.1
MISCELLANEOUS
7.
SH010A
C/P
Cylinder
thermostat
Thermal
cut-out
1 C/P
Not
used
23
Randall 3020 P
and 3060
HTG
ON
3
L
PROGRAMMER
4
3
10
10
Towerchron MP
Link 1-4/6-11
Towerchron FP
Link 1-5/4-7-9
HW
ON
Sunvic ET 1451
Link 2-3-6
Towerchron 2000
Switchmaster
Symphony, Sonata
BOILER
10
PROGRAMMER
Sangamo M5
Link 1-6
Randall 4033
Link 1-6
Randall 102/102 E
Link 3-6
P
3
1
3
10
Potterton Miniminder
240V
MAINS INPUT (3 AMP)
E
L
7
V4043H
HOT WATER VALVE
GREEN/YELLOW
6
10
ORANGE
GREY
5
BLUE
Drayton Tempus 7
BROWN
E
V4043H
HEATING VALVE
10
ORANGE
GREEN/YELLOW
Pegler Sunvic
SP 50/100 (Link L-3)
GREY
2
1
TYPICAL
JUNCTION BOX
BLUE
T6360B
ROOM
THERMOSTAT
BROWN
7.2
WIRING DIAGRAM FOR
CONNECTION TO AN
ARISTON UNVENTED
CYLINDER
SH009A
TECHNICAL INFORMATION
max/min kW
max/min kW
%
%
%
%
%
Kg/h
mbar
m3/h
m3
Kg/h
C
%
O2 Content
CO Content
Minimum Ambient Temperature
Head Loss on Water Side (max) (T=20C)
Residual Head of System
Heating Temperature
Domestic Hot Water Temperature
D.H.W. Flow Rate T=35C
D.H.W. Flow Rate T=35C
D.H.W. Minimum Flow Rate
Pressure of Domestic Hot Water
Expansion Vessel Capacity
Expansion Vessel Pre-load Pressure
Maximum Water Content of System
Maximum Heating Pressure
Nominal Pressure
Natural Gas (G20)
LPG (G30-G31)
Electrical Supply
Power Consumption
Protection Grade of Electrical System
Internal Fuse Rating
Weight
ppm
C
mbar
bar
max/min C
max/min C
l/min
gal/min
l/min
max/min bar
l
bar
l
bar
mbar
mbar
V/Hz
W
IP
Kg
G.C. Number
*Calculated at 70% maximum output
Manufacturer:
27 MFFI
63AU4549
25.6/11.0
63AU4549
29.8/12.0
92.9
91.1
1.0
6.1
0.4
49.5
0.96
93.5
90.7
0.2
6.3
0.4
60
1.60
2.72
3.15
0.32/0.39
2.02/2.00
123
7.2
0.37
2.34/2.31
128.8
6.9
7.5
8.1
51.9
+5
200
0.25
82/42
56/36
9.7
2.2
2.6
8/0.2
6
1
130
3
20
30-37
230 / 50
140
X4D
FAST 2 AT
38
48
+5
200
0.25
82/42
56/36
11.4
2.6
2.6
8/0.2
6
1
130
3
20
30-37
230 / 50
155
X4D
FAST 2 AT
39
47-116-14
47-116-15
RECANATI
23 MFFI
CE Certification
Heat Input
Heat Output
Efficiency of Nominal Heat Input
Efficiency at 30% of Nominal Heat Input
Heat Loss to the Casing (T=50C)
Flue Heat Loss with Burner Operating
Flue Heat Loss with Burner Off
Maximum Discharge of Fumes (G20)
Residual Discharge Head
7.
Servicing
Instructions
Type C Boilers
G.C.N: 47-116-14
47-116-15
LEAVE THESE INSTRUCTIONS
WITH THE END-USER
Country of destination: GB
TABLE OF CONTENTS
1.
SERVICING INSTRUCTIONS
1.1
REPLACEMENT
1.2
1.3
1.4
1.5
1.6
2.
FAULT FINDING
2.1
3.
ELECTRICAL DIAGRAMS
4.
OF
PARTS
B063
1.
SERVICING INSTRUCTIONS
1.1
REPLACEMENT
OF
FIG. 1.4
PARTS
1.2
FIG. 1.1
19.eps
16.eps
FIG. 1.2
13.eps
B063
FIG. 1.5
14.eps
FIG. 1.3
3
FIG. 1.8
D
18.eps
FIG. 1.6
98.tif
FIG. 1.9
17 eps
FIG. 1.7
97.tif
B063
1.3
Fig. 1.12
78 eps
E
E
FIG. 1.13
FIG. 1.10
99.tif
49 eps
FIG. 1.11
12 eps
50 eps
B063
FIG. 1.14
FIG. 1.15
51 eps
Fig. 1.17
75 eps
11 eps
76 eps
52 eps
FIG. 1.16
FIG. 1.18
6 eps
FIG. 1.19
B063
FIG. 1.20
FIG. 1.23
K
N
N
L
90.tif
93.tif
FIG. 1.21
Q
P
M
FIG. 1.24
94.tif
91.tif
FIG. 1.25
95.tif
FIG. 1.22
FIG. 1.26
B063
96.tif
1.4
B
A
VG001Aa
D
C
VG001Ac
VG001Ab
8 mbar
16 mbar
16 mbar
VG001Ad
B063
model 23
model 27
CG007A
CG008A
40
38
36
34
model 23
model 27
CG009A
27 MFFI
23 MFFI
TABLE A
2.70
2.01 Kg/h
2.00 Kg/h
1.16
0.87 Kg/h
0.85 Kg/h
20
28 mbar
37 mbar
11.0
27.7 mbar
35.5 mbar
2.0
6.0 mbar
7.3 mbar
12 x 0.77
12 x 0.77
3.15
2.34 Kg/h
2.31 Kg/h
1.26
0.94 Kg/h
0.93 Kg/h
20
28 mbar
37 mbar
11.0
27.7 mbar
35.5 mbar
1.6
4.6 mbar
6.0 mbar
14 x 1.30
14 x 0.77
14 x 0.77
TB012A
B063
61.eps
T
Soft-light
Adjustment
Max Heating
Adjustment
VR015A.eps
FIG. 1.27
45.eps
10. Remove the pipe from the pressure gauge and connect
screw C to the pressure outlet in order to seal off the
gas.
11. Carefully check the pressure outlets for gas leaks (valve
inlet and outlet).
IMPORTANT!
Whenever you disassemble and reassemble the gas
connections, always check for leaks using a soap and water
solution.
10
43.eps
FIG. 1.28
44.eps
FIG. 1.29
B063
1.6
W
Y
FIG. 1.30
47.eps
FIG. 1.33
22.eps
48.eps
38.eps
B063
FIG. 1.31
21.eps
FIG. 1.34
68.eps
FIG. 1.35
FIG. 1.32
11
B1
FIG. 1.36
40.eps
FIG. 1.40
53.eps
C1
FIG. 1.37
37.eps
C1
FIG. 1.41
54.eps
A1
12
39.eps
Fig. 1.38
41.eps
Fig. 1.39
B063
G1
FIG. 1.44
42.eps
D1
H1
FIG. 1.41
31.eps
FIG. 1.45
32.eps
E1
I1
I1
FIG. 1.42
33.eps
35.eps
FIG. 1.46
25.eps
FIG. 1.47
F1
34.eps
B063
FIG. 1.43
13
1.
2.
3.
4.
K1
J1
K1
FIG. 1.50
77.eps
34.eps
FIG. 1.48
L1
FIG. 1.51
57.eps
27.eps
FIG. 1.49
M1
58.eps
59.eps
14
FIG. 1.52
FIG. 1.53
B063
Q1
N1
FIG. 1.57
60.eps
FIG. 1.54
80.eps
R1
S1
FIG. 1.55
83.eps
FIG. 1.58
74.eps
V1
P1
FIG. 1.56
B063
87.eps
30.eps
T1
FIG. 1.59
15
1.6
W1
72.eps
FIG. 1.60
FIG. 1.62
69.eps
W2
61.eps
FIG. 1.61
1189.jpg
1190.tif
16
FIG. 1.63
FIG. 1.64
B063
Y1
Y1
82.eps
FIG. 1.65
64.eps
X1
X1
B063
FIG. 1.68
X1
X1
X1
X1
1187.eps
FIG. 1.66
65.eps
FIG. 1.67
17
2.
FAULT FINDING
2.1
It is possible to detect and correct any defect by using the standard fault
finding diagrams described in this chapter.
PRELIMARY CHECKS
MAKE SURE THAT:
1 - There is sufficient water in
the system
2 - The gas is turned on
3 - The electrical supply is
turned on
TURN ON THE ON/OFF
SWITCH
IS
THE POWER
L.E.D.
ON?
NO
1 - Check the fuses
2 - Check the power supply
cable, plug and outlet
3 - Check/replace the power
supply to the P.C.B.
YES
POSTION
OF THE
SELECTOR
SUMMER
ESTAT E
WINTER
Comfort
ECONOMY/
COMFORT
SELECTOR
NO
Comfort
TEMP.
C.H. < 34C
Economy
YES
TEMP.
C.H. < 34C
NO
YES
D.H.W. IS
BEING DRAWN?
NO
Economy
NO
YES
ECONOMY/
COMFORT
SELECTOR
D.H.W. IS
BEING DRAWN?
YES
NO
1 - Check/reset system
pressure
2 - Check/restore gas
supply
3 - Check/replace shortcircuited heating probe
4 - Check/replace siezed
pump
NO
NO
FOR BOILERS
WITH ELECTRONIC
ANTI-FROST DEVICE:
PROTECTION IS ACTIVATED
IF HEATING TEMP
IS < 5C
YES
MUST
TIME CLOCK
AND/OR ROOM
THERMOSTAT
BE ACTIVATED?
NO
YES
YES
1 - Check/reset the
system pressure
2 - Check/restore
gas supply
3 - Check/replace shortcircuited heating probe
4 - Check/replace
siezed pump
FOR BOILERS
WITH ELECTRONIC
ANTI-FROST DEVICE:
PROTECTION IS ACTIVATED
IF HEATING TEMP
IS < 5C
NO
FC004Aa
18
B063
IS THE PUMP
RUNNING?
NO
YES
POWER TO
THE PUMP?
NO
YES
YES
1 - Check if there is air in the
system
2 - Check main circuit flow switch
operation
3 - Check pressure on the water
gauge and fill system to return
to 1 bar
DOES THE
"NO WATER" L.E.D.
ILLUMINATE
(WITHIN 40 SECS)?
NO
FC004Ab
B063
19
IS THE FAN
RUNNING?
YES
NO
BOILER
SHUTDOWN?
YES
YES
1 - Check/replace main
circuit flow switch
2 - Check/replace
connection cable
3 - Check/replace P.C.B.
NO
C
PUMP PROTECTION
ACTIVATED?
NO
INTERNAL
P.C.B. PROTECTION
ACTIVATED?
YES
1 - Check/replace air
pressure switch
2 - Check if reset button
is jammed
3 - Check/replace flame
detection electrodes
NO
POWER
TO FAN?
NO
1 - Check/replace
connection cable
2 - Check/replace P.C.B.
3 - Check/replace air
pressure switch
YES
1 - Replace fan
FC004Ac
20
B063
C
IS THE
AIR PRESSURE SWITCH
ACTIVATED?
NO
CHECK
YES
P ON TEST
PRESSURE
INTAKE
P 1.2 mbar
P 1.2 mbar
IS FLUE
DISCHARGE
NORMAL?
1 - Check/replace ignition
electrode
2 - Check ignition cable
3 - Check spark generator
4 - Check ignition electrode
cable
5 - Check/replace P.C.B.
NO
YES
IS THE BURNER
ALIGHT?
NO
YES
YES
HAS THE
BOILER SAFETY
SHUTDOWN BEEN
ACTIVATED?
NO
NO
HAS THE
BOILER SAFETY
SHUTDOWN BEEN
ACTIVATED?
YES
Shutdown L.E.D. off
fan restarts
FC004Ad
B063
21
D
IS
THERE STILL
A PROBLEM?
NO
FAULTS
YES
1 Drawing D.H.W:
When you turn on a tap
burner switches off
2 Drawing D.H.W:
radiators heat up in summer mode
3 Drawing D.H.W:
NORMAL
OPERATION
4 Drawing D.H.W:
noisy operation
5 Decrease/increase
heating circuit pressure
6 Repeated shutdowns
POSSIBILE CAUSES
- air in secondary heat exchanger
- faulty main circuit flow switch
- faulty D.H.W. flow switch
- faulty 3-way valve
- check C.H./D.H.W. temperature probes
- check gas pressures
- check water flow rate
- check secondary heat exchanger
- primary heat exchanger faulty or
lime-scale deposits
- low heating system water pressure
- check gas pressures
- check C.H./D.H.W. temperature probes
- check for leaks on the heating circuit
- faulty filling-loop
- faulty secondary heat exchanger
- expansion vessel faulty
- faulty detection electrodes
- check gas settings
- check flame detection electric circuit
FC004Ae
22
B063
3.
ELECTRICAL
LEGEND:
DIAGRAMS
A
B
=
=
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
V
U
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
A01
A02
A03
A04
A05
A06
A07
A08
A09
A10
A11
A12
A13
A14
=
=
=
=
=
=
=
=
=
=
=
=
=
=
Colours:
Gry
=
Wh
=
Pnk
=
Brn
=
Bl
=
Blk
=
Rd/Blk =
B063
Circulation Pump
Fan
Spark Generator/Gas Valve Supply
Motorised Diverter Valve
Flame Detection Circuit
Detection Electrode
Main Circuit Temperature Probe
Domestic Hot Water Temperature Probe
Domestic Hot Water Flow Switch
Main Circuit Flow Switch
Modulator
Air Pressure Switch
Safety Thermostat
External (Room) Thermostat
Grey
White
Pink
Brown
Blue
Black
Red/Black
23
24
N
Blk
Rd/Blk
Brn
Brn
Brn
Wh
Wh
Wh
Brn
Wh
Rd/Blk
Wh
Wh
Blk
Blk
Blk
Blk
Gry
Gry
Rd/Blk
Wh
Pnk
Blk
Blk
Gry
Gry
Pnk
Pnk
SE017A
SF014A
B063
4.
SHORT SPARE
PARTS LIST
microGENUS 23/27 MFFI
9
62 61 60
59 58 57 56 9 55
54
53
304
52
51
1
50
2
63
3
56
65
9
56
64
108
66
301
56
107
106
302
303
49
7
105
8
67
9
10
10
48
104
103
68
47
102
69
97
70
71
45
98
99
100
71
11
72
73
12
13
12
14
74
44
13
77
80
15
79
16
81
78
83
82
95
85
86
84
77
43
96
75
76
14
46
101
42
42
41
94
87
14
93
92
91
90
88
25
17
34
40
89
14 18 19 20 21 18 22
23 24
code 998613
25
26
27 28
29 30 31
32 33
34
35
36 37 38
39
codes 998836
999091
code 998940
352
331
334
351
311
353
333
332
354
code 998099
code 997089
371
372
373
374
375
B063
321
MODELS
CHARACTERISTICS
SERIAL NO:
VALIDITY
REF.
MICROGENUS 23 MFFI
MICROGENUS 23 MFFI
METHANE
LPG
2320005600001
2320005600001
A
B
MICROGENUS 27 MFFI
METHANE
2320005600001
MICROGENUS 27 MFFI
LPG
2320005600001
25
26
G.C. part
no.
379816
E61
468
164 282
E61 475
164 225
E25 427
E61 429
164 338
E61 478
E24 077
E61 479
E61 482
E61 483
E25 529
E61 848
E61 485
E61 490
E61 881
E61 519
E61 520
E61 530
E03 818
E61 967
E25 425
E61 546
E61 547
E61 549
E61 972
E61 974
E26 767
E26 657
E26 658
E26 378
E61 565
E61 567
E61 569
E25 582
E61 647
E61 648
E61 649
E61 650
E61 652
E61 654
E61 656
E61 660
E62 030
E24 077
E24 077
E24 076
E24 075
E61 663
E61 665
E61 667
ARISTON
Part No.
Description
Expansion vessel
Gasket 3/8"
O-ring
Gasket 3/4"
Motor (3- Way valve)
Fixing clip (motor)
Temperature probe (C.H.W.)
Flow group
Diaphragm (main flow switch)
Main circuit flow switch
Return group
O-ring
Gasket
Spark generator
Gas valve (SIT 845 SIGMA)
Pump
Pump
Time clock
P.C.B. (CMP1-FFI)
Pressure gauge
Air pressure switch
Air pressure switch
Fan
Fan
Thermostat (overheat)
Main exchanger
Main exchanger
Burner 12 ramp (natural gas)
Burner 12 ramp (LPG)
Burner 14 ramp (natural gas)
Burner 14 ramp (LPG)
Secondary exchanger (p-type 23kW)
Secondary exchanger (p-type 27kW)
O-ring (secondary exchanger)
Safety valve (1/2" 3 bar)
Electrode (Ignition R.H.)
Electrode (Ignition L.H.)
Detection electrode
D.H.W. actuator kit
Operator coils (SIT SIGMA)
Central heating by-pass kit
Heating spring kit
3-way spring kit
Actuator bush
Gasket (auto air vent)
Auto air vent
Gasket (pump head)
Pump head (Gold 15/5)
Pump head
Diaphragm (main flow switch)
Magnet (main flow switch)
Spring (main flow switch)
Main flow switch top cap
Main flow switch reed system
Burner jet 1.25 full kit (Natural gas)
Burner jet 0.72 full kit (LPG)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
998616
573521
998077
573520
997147
997077
569236
998613
571547
998099
998940
998424
574279
998645
997089
998836
999091
999599
998947
999245
573989
571651
999397
998894
997206
998620
998893
998618
998669
998887
998939
571646
573295
573825
573172
998623
998622
998624
998941
997029
998490
998718
998975
998974
998644
998643
998738
998961
999207
571547
571772
571771
571770
998172
998716
998717
B063
23 99 84 1470 312 -
Manufacturer:
MICROGENUS 23 MFFI
MICROGENUS 27 MFFI
Edition 1 of 1 December 1999
62 61 60
59 58 57 56 9 55
54
53
304
52
51
1
50
2
63
3
56
9
56
5
64
105
301
56
104
103
302
303
49
7
102
65
8
9
10
10
66
48
101
100
47
99
67
94
68
69
45
95
96
97
69
11
70
71
12
13
12
14
72
44
13
75
15
77
16
78
76
92
83
84
82
75
43
93
73
74
14
46
98
81
80
41
85
14
79
42
42
25
17
34
91
90
89
88
86
40
87
14 18 19 20 21 18 22
23 24
code 998613
25
26
27 28
29 30 31
32 33
34
35
36 37 38
39
code 998836
code 998940
352
331
334
351
311
353
333
332
354
code 998099
code 997089
371
MODELS
CHARACTERISTICS
SERIAL NO:
VALIDITY
REF.
MICROGENUS 23 MFFI
METHANE
9932200020
MICROGENUS 23 MFFI
LPG
9932300018
MICROGENUS 27 MFFI
METHANE
9932500011
MICROGENUS 27 MFFI
LPG
9932400027
372
373
374
375
321
-----998616
998776
998581
573521
998584
998580
-----570717
998569
998589
998077
998064
573520
998815
997147
997077
569236
998613
571547
998099
998632
999075
998940
998424
574279
998645
997089
998606
998568
997182
998452
998836
998570
998575
998603
998572
997207
998827
998824
998642
569711
998625
----------571548
998861
998859
998863
573327
571575
571651
573989
997203
573329
569662
998516
-----998565
998636
998602
998637
998595
998648
998566
Frame
Expansion vessel
Bush
3/8" lock nut
3/8" gasket
Pipe (expansion vessel)
Cable holder
Hydraulic group support
Spring (fastening)
Pivot
By-pass pipe
O-ring gasket
Spring (by-pass pipe)
Gasket 3/4"
Pipe (flow)
Motor (3-Way valve)
Fixing clip (motor)
Temperature probe (C.H.W.)
Flow group
Diaphragm (main flow switch)
Main circuit flow switch
Cable (temperature probes)
D.H.W. flow switch
Return group
O-ring
Gasket
Spark generator
Gas valve (SIT 845 SIGMA)
Pump bracket
Pump plug
Gasket
Lock washer
Pump
L.E.D.
Spindle (temperature knob)
Control knob
Spindle (on/off knob)
Time clock
Front cover
Control panel
Printed circuit board (CMP1-FFI)
Nylon bush (10mm)
Pressure gauge
Control panel
Cable holder cover
Clip (Main Flow Switch)
Cable (power supply)
High voltage wiring
Low voltage wiring
"Y" piece (air pressure)
Silicone pipe (positive signal)
Air pressure switch
Air pressure switch
Support plate (Air pressure switch)
Pressure intake cover
Silicone pipe
10x6 adhesive gasket
Sealed chamber
Cover (flue test point)
Gasket (flue test point)
Flue (exhaust manifold/header)
Flange gasket
Plug (air intake)
Sealed chamber wiring
Fixing clamp (fan)
REF.
NOTE
11
11
11
11
CD
AB
11
998601
998621
998894
998640
998896
998600
998639
997206
998583
998620
998893
998618
998669
998887
998939
571646
573295
573825
998629
998567
573176
573172
573576
573325
569443
572138
998714
998715
998729
998732
997153
998604
998571
998605
998579
998862
569720
998517
998623
998622
998624
998147
998599
998598
998924
998719
998925
998638
998895
998076
998075
998610
301
302
303
304
998477
998596
998476
998607
311
998941
321
997029
331
332
333
998490
998718
571447
REF.
AB
AB
CD
AB
CD
AB
CD
A
B
C
D
AB
CD
AC
BD
AB
CD
AB
CD
AB
CD
NOTE
998013
351
352
353
354
998644
998643
998738
998961
O-ring (A.A.V.)
Auto Air Vent
Gasket (pump head)
Pump head
371
372
373
374
375
571547
571772
571771
571770
998172
381
382
998716
998717
NOTE DESCRIPTION
11
12
REF.
NOTE
12
12
MICROGENUS 23 MFFI
MICROGENUS 27 MFFI
Edition 1 of 1 December 1999
62 61 60
59 58 57 56 9 55
54
53
304
52
51
1
50
2
63
3
56
9
56
5
64
105
301
56
104
103
302
303
49
7
102
65
8
9
10
10
66
48
101
100
47
99
67
94
68
69
45
95
96
97
69
11
70
71
12
13
12
14
72
44
13
75
15
77
16
78
76
92
83
84
82
75
43
93
73
74
14
46
98
81
80
41
85
14
79
42
42
25
17
34
91
90
89
88
86
40
87
14 18 19 20 21 18 22
23 24
code 998613
25
26
27 28
29 30 31
32 33
34
35
36 37 38
39
code 998836
code 998940
352
331
334
351
311
353
333
332
354
code 998099
code 997089
371
MODELS
CHARACTERISTICS
SERIAL NO:
VALIDITY
REF.
MICROGENUS 23 MFFI
METHANE
9932200020
MICROGENUS 23 MFFI
LPG
9932300018
MICROGENUS 27 MFFI
METHANE
9932500011
MICROGENUS 27 MFFI
LPG
9932400027
372
373
374
375
321
-----998616
998776
998581
573521
998584
998580
-----570717
998569
998589
998077
998064
573520
998815
997147
997077
569236
998613
571547
998099
998632
999075
998940
998424
574279
998645
997089
998606
998568
997182
998452
998836
998570
998575
998603
998572
997207
998827
998824
998642
569711
998625
----------571548
998861
998859
998863
573327
571575
571651
573989
997203
573329
569662
998516
-----998565
998636
998602
998637
998595
998648
998566
Frame
Expansion vessel
Bush
3/8" lock nut
3/8" gasket
Pipe (expansion vessel)
Cable holder
Hydraulic group support
Spring (fastening)
Pivot
By-pass pipe
O-ring gasket
Spring (by-pass pipe)
Gasket 3/4"
Pipe (flow)
Motor (3-Way valve)
Fixing clip (motor)
Temperature probe (C.H.W.)
Flow group
Diaphragm (main flow switch)
Main circuit flow switch
Cable (temperature probes)
D.H.W. flow switch
Return group
O-ring
Gasket
Spark generator
Gas valve (SIT 845 SIGMA)
Pump bracket
Pump plug
Gasket
Lock washer
Pump
L.E.D.
Spindle (temperature knob)
Control knob
Spindle (on/off knob)
Time clock
Front cover
Control panel
Printed circuit board (CMP1-FFI)
Nylon bush (10mm)
Pressure gauge
Control panel
Cable holder cover
Clip (Main Flow Switch)
Cable (power supply)
High voltage wiring
Low voltage wiring
"Y" piece (air pressure)
Silicone pipe (positive signal)
Air pressure switch
Air pressure switch
Support plate (Air pressure switch)
Pressure intake cover
Silicone pipe
10x6 adhesive gasket
Sealed chamber
Cover (flue test point)
Gasket (flue test point)
Flue (exhaust manifold/header)
Flange gasket
Plug (air intake)
Sealed chamber wiring
Fixing clamp (fan)
REF.
NOTE
11
11
11
11
CD
AB
11
998601
998621
998894
998640
998896
998600
998639
997206
998583
998620
998893
998618
998669
998887
998939
571646
573295
573825
998629
998567
573176
573172
573576
573325
569443
572138
998714
998715
998729
998732
997153
998604
998571
998605
998579
998862
569720
998517
998623
998622
998624
998147
998599
998598
998924
998719
998925
998638
998895
998076
998075
998610
301
302
303
304
998477
998596
998476
998607
311
998941
321
997029
331
332
333
998490
998718
571447
REF.
AB
AB
CD
AB
CD
AB
CD
A
B
C
D
AB
CD
AC
BD
AB
CD
AB
CD
AB
CD
NOTE
998013
351
352
353
354
998644
998643
998738
998961
O-ring (A.A.V.)
Auto Air Vent
Gasket (pump head)
Pump head
371
372
373
374
375
571547
571772
571771
571770
998172
381
382
998716
998717
NOTE DESCRIPTION
11
12
REF.
NOTE
12
12