Professional Documents
Culture Documents
Aqua Flow
Aqua Flow
AquaFlow
Equipments
AquaFlow 2-Port
Heat Exchanger
AquaFlow 3-Port
AquaFlow 4-Port
AlfaNova
AlfaNova is the worlds first and only heat exchanger made of 100% stainless steel
High heat transfer
Corrosion resistance
Maximum cleanliness
100% copper free, suitable for all DHW pipeworks
Insulation
Copper Brazed
Thermal efficiency for optimum comfort and reliability
Increased turbulence to increase heat transfer and reduce fouling
Temperature stability
Compact design (large heat transfer surface within a small footprint)
Insulation
Plates&Gaskets
Cost effective tap water production
Compact design
AISI316 plates & EPDM Clip-On Gaskets
Insulation
Control Valve
2-Port Electronic
24V 0-10V with safety
230V 3 Pts with safety
2-Port Self-Actuating with safety
3-Port Electronic
24V 0-10V
230V 3 Points
with or without safety
4-Port Electronic
24V 0-10V
230V 3 Points
Controller
Primary Pump
Charging Pump
Valves
Plates&Gaskets
Copper Brazed
or AlfaNova
AquaFlow 3-Port
AquaFlow 4-Port
Capacity
Primary
Flow Rate
Secondary
Flow Rate
Capacity
Primary
Flow Rate
Secondary
Flow Rate
Capacity
Primary
Flow Rate
Secondary
Flow Rate
kW
m3/h
L/min
kW
m3/h
L/min
kW
m3/h
L/min
90C 10/55C
1100
17.5
352
1220
20.4
390
1370
24
437
80/60C 5/70C
340
15
75
400
17.7
77
500
22.2
110
82C 10/60C
750
15
216
945
20.5
272
1140
25.5
327
320
14.1
92
65/45C 10/60C
370
17
107
350
15.4
100
M90C 10/55C
1000
13
320
950
12.1
304
80/60C 5/70C
205
45
270
12
58
82/25C 10/60C
800
12.4
231
800
12.1
230
75/25C 10/60C
500
8.8
144
On Request
Plates&Gaskets
Copper Brazed
AlfaNova
AquaFlow 3-Port
AquaFlow 4-Port
Primary
Secondary
Primary
Secondary
Primary
Secondary
10 Bar
10 Bar
10 Bar
10 Bar
6 Bar
10 Bar
110C
90C
110C
90C
110C
90C
25 Bar*
10 Bar
10 Bar
10 Bar
130C
90C
110C
90C
25 Bar*
10 Bar
10 Bar
10 Bar
130C
90C
110C
90C
On Request
Hydraulic chart
Primary inlet
Entree primaire
Primary inlet
Entree primaire
Primary outlet
Sortie primaire
Primary outlet
Sortie primaire
CW
CW
Gate valve
Vanne isolement
Gate valve
Vanne isolement
Version de base
Basic version
Setting valve
Setting valve
VR Vanne reglage
VR Vanne reglage
VA
PP
Primary pump
Pompe primaire
Th
Safety thermostat
Thermostat de securite
DC
Drain cock
Vanne de vidange
DHW/ECS
HE
V'
V
PRV
PR
V'
VA
PP
Primary pump
Pompe primaire
Th
Safety thermostat
Thermostat de securite
DC
Drain cock
Vanne de vidange
VR
CW
DHW / ECS
V'
PRV
S3
PR
V
V'
VR
S2
CW
B
V
Kit primaire 3P
Primary kit 3P
A
HE
Th
HE
VA
HE
Th
DHW/ECS
VA
PP
HE
VA
A
DHW/ECS
A
V
V'
PRV
PR
V
V'
PRV
VR
S3
CW
V
V'
PR
V'
VR
S2
CW
B
V
AquaFlow is built in compliance with PED CE 97/23 Art 3.3 or PED 1 and CE 73/23 electrical regulation.
AquaFlow is assembled, wired and tested prior to shipment.
ECF00186EN 0907