Linear Scale
Linear Scale
CARMAR
PRECISION INSTRUMENT CO., LTD.
VER: 1.03
Content
Please carefully read the preface before operating
1.
2.
3.
Specification ........................................................................... 5
3.1. Device Model................................................................... 5
3.2.Table of Specification ....................................................... 6
3.3. Output Signal ................................................................... 7
4.
2.
3.
4.
5.
Be far away from the strong acid and alkali as well as the
chemicals.
Keep the signal cable of the linear scale far from the
power cords as possible.
Take the way of installation into consideration when
using the device in the situations of high voltage, strong
current or magnetic field. do well in isolating the
haphazard signals and avoid the disturbance of such.
Other Requirements
I.
II.
III. Make sure that the plugs of the signal cable are well and
stably plugged onto the corresponding interface.
IV. Design the application of the linear scale according to its
effective travel range, and avoid the occurrence of surpassing
the effective range and the damage of the device.
V. Do not let dust pile up on the linear scale and the read-head or
the track of the moveable body of the linear scale.
VI. Be sure to turn off the power before unplugging the connecter
of the signal cable.
Daily Maintenance
I. Check the device after uncovering the package. Please
immediately contact the dealer as soon as possible if the
components are not complete or the malfunction needs
settling. Do not disassemble or modify it at your wishes.
II. Do not clean the dust on or around the read-head and the
moveable body with forced strength or air, for it may result in
I. Warranty
In normal cases, the linear scale is guaranteed one years repair
since it was sold.
2. Instrument Consistency
1. Linear scale
1pcs
1pcs
1pcs
4. Packing list
5. Accessory pack
1pcs
1pcs
3. Specification
3.1. Device Model
3.2.Table of Specification
LSslim scale
Item
Resolutionm
1, 5
50~1000
LE(thick scale)
50~3000
Maximum
50L900 L+30
Movementmm
L950
Distance between
50L900 L+132
L+136
holes (mm)
L950
L+152
L+156
50L900 L+149
L+154
(mm)
L950
L+174
L+50
L+169
3.5;(L150,300L950) 3.5;(L950)
Length of the signal cable (M)
5;(L=200,250,1000)
5;(1000L1900)
10;(2000L3000)
Thicknessmm
21
29
60
60
50.25
Work waste
Reserving temperature()
0~50
Working temperature()
0~40
A /B /R I O u tp u t s ig n a l
A /B /R I O u tp u t s ig n a l
COUNTER
R1
R2
A/B/RI
+
C1
R3
C2
74HCT14
R1=68 C1=1000PF
R2=100 C2=100PF
R3=10K
TTL Interface
SCALE
COUNTER
10
26LS31
Vcc
A/B/RI
R2
26LS32
+
R1
R3
A/B/RI
ANTENNA
10
RS422 Interface
R1=120
R2=R3=5K
TTL socket(standard)
PIN
1
2
3
4
5
9
2) 15PD-TTL socket(opt)
PIN
1
2
3
4
5
9
1
2
3
4
5
6
7
PIN
1
2
3
4
5
6
PIN
Current
35mA
35mA
4mA
4mA
4mA
Current
35mA
NC
A
B
+5V
RI
FG
Brown
Yellow
Red
Orange
Output
Output
Input
Output
4mA
4mA
35mA
4mA
Weaving net
Current
35mA
4mA
4mA
4mA
35mA
Current
35mA
35mA
4mA
4mA
4mA
4mA
4mA
4mA
e
t
i
h
W
/
n
1
2
3
4
5
6
7
8
9
Current
35mA
35mA
4mA
4mA
4mA
the
cale
o e ent
54
ain
cale
3
L
44 5
3 5
o e ent
3 5
ecti e
the
2-M5-6H
A
2-M4-6H Hight 8
W B
erie
ecti e
o e ent
Max Range
L900
L+30
L+136
L+154
L900
L+50
L+156
L+174
above
10
39.2
20
61.5
60
90
2-M5-6H
11
21
1.3
25.5
20
Effective movement = L
20.5
10.25
5 8
2-M4-6H Height 7
10.25
60 0.1
Max range
L900
L+30
L+132
L+149
L900
L+50
L+152
L+169
above
11
Body
Left head
Read head
Signal cable
4. Installation
4.1 Notice for Installation
1. The effective movement of the linear scale should be larger than the
maximum travel of the worktable. If it is not long enough, change a long
-er one or install fixing blocks on the worktable. Not less than 10mm
space should be spared between the end of the Read Head and the body
of the scale.(Figure 4.1)
Figure 4
12
The groove of the linear scale must avoid the direct shock of met
-al powder, oil, water and dust (Figure4.2).
13
Incorrect in tallation
C o rre c t in s ta l la tio n
igure 4
igure 4 3
igure 4 4
7. You must consider all the relevant moving distance before fixing the
signal cable. The fixing position should be placed in the middle of the
track as possible as you can. And then well bundle the surplus cable.
8. Make sure that the ground wire is grounded, and measure from the cover
of the Read Head to the ground terminal of the signal processing device
with a volt-ohm meter (the ground connector of the DRO). confirm the
resistance is not more than 0.3 (Resistance0.3).
9. Based on the center of the linear scale, you must take the point of
symmetry of the two sides as the criteria point when adjusting the height
and level of the linear scale. As to any linear scale, whenever you
perform the horizontal adjustment or vertical adjustment, for the body of
the linear scale itself, the range of the adjustment cant individually
exceed 20mm from the end of the meter to the body of the scale
(Figure4.5). As for the Read Head, perform the adjustment within the
two square standard sides (Figure 4.6)
igure 4
igure 4 5
15
R>
60
60mm.
Figure 4.7
16
igure 5
2.
igure 5
17
igure 5 3
3.
Standard of Read-Head:
The interval between the read-head and
the body of the scale should range from
0.8mm to 1.6mm. Use a cushion to
adjust the interval when installing the
read-head after it is well installed, draw
out the cushion (Figure 4.11).
Theside of the read-head and the
side of the body disturb horizontally.
The value:LE:0.5 0.15mm
5 4
Notice:
In the figures, R indicates the crooked radius; F: the track of
the worktable; L: the effective movement of the linear scale;
K: the installation dimensions.
18