Laparascopic Uterine Elevator
Laparascopic Uterine Elevator
Laparascopic Uterine Elevator
Uterine Manipulation
in Laparoscopic
Hysterectomy
Gamal H. Eltabbakh, MD
ELTABBAKH
FUNCTION
A uterine manipulator performs the following functions:
Raises the uterus and brings it closer to the
laparoscopic surgical instruments, facilitating the procedure
Manipulates the uterus, thus stretching
the side being operated upon
Increases the distance between the
uterus and the bladder, the ureters, and
the rectum, thus reducing the chance of
injury
Could be used to pull the uterus vaginally
after its complete detachment
Facilitates identification of the uterovesical peritoneum, the cul-de-sac, and
the vaginal cuff just below the cervical
attachment
Maintains the pneumoperitoneum following colpotomy.
CHARACTERISTICS
Despite their obvious advantages, there are
no published reports on whether the use of
uterine manipulators reduce operative morbidity or decrease operative time. An ideal
uterine manipulator will have the following
characteristics:
Easy to assemble
Inexpensive
Does not fragment or break down into
pieces during the procedure
Has a wide range of movement and mobilizes the uterus in different directions
(anteversion, retroversion, and lateral
movement)
Is easily placed inside the uterus and will
stay in place all through the procedure
The point of articulation is at the external
os of the cervix and not at the perineum,
thus making movement of the uterus and
cervix easier and independent of the patients weight and resistance encountered
at the perineum.
Some uterine manipulators come in different lengths to adapt to uteri of different
sizes. Some have a cannula intended to perform such functions as chromotubation to
test tubal patency. Such a cannula is not a
necessary part of the uterine manipulators
used for hysterectomy. Some manipulators
are reusable (eg, the Hulka clip, the Cohen
cannula, and the Pelosi); some are disposable (eg, VCare, the Endopath, and ZUMI
Zinnanti); and some are partially disposFollow The Female Patient on
and
AVAILABILITY
There are many uterine manipulators available, and they vary from one country to
another and from one hospital to another.
The most commonly used manipulators include a sponge stick, the Hulka clamp, the
Cohen cannula (Aesculap), the Pelosi
(Apple Medical Corporation), the Zinnanti
(Hayden Medical Inc), the RUMI System
(CooperSurgical), the ZUMI (HNM Medical), UMI (U.A. Medical Products), the
VCare (ConMed Endosurgery), the Endopath (Ethicon Endo-Surgery), the ClearView (Clinical Innovations), Valtchev
(Conkin Surgical Instruments), and EZ
Glide (B & H Surgical). The RUMI manipulator is often used with the KOH colpotomizer ring if total laparoscopic hysterectomy is to be performed. Some physicians use
cervical dilators as uterine manipulators.
New uterine manipulators are being developed by several investigators worldwide.
Ramirez and colleagues developed a modified uterine manipulator that allows removal of an adequate (2-cm) margin of the
upper vagina while maintaining adequate
pneumoperitoneum among women undergoing laparoscopic radical hysterectomy.3
In the United States, the 2 most commonly used uterine manipulators for the
da Vinci robotic total laparoscopic hysterectomy have been the RUMI manipulator
with the KOH colpotomizer ring (Figure 1)
and the VCare manipulator (Figure 2).
Each of these manipulators comes in 3 different sizes. Changes in the forward cup
polymers allow the VCare to be used with
both electrosurgical and harmonic energy
sources.
FOCUSPOINT
There are
many uterine
manipulators
available, and
they vary from
one country to
another and
from one
hospital to
another.
PROCEDURE
The uterine manipulator is placed after anesthesia is administered. A prophylactic antibiotic is given, and the patient is prepped
and draped in the usual fashion. A Foley
catheter is then inserted and bimanual examination performed to assess the size and
position of the uterus. A Pederson or vaginal
speculum opened on the side or 1 or 2 Sims
vaginal retractors are placed, and the cervix
is visualized.
FOCUSPOINT
The uterine
manipulator is
placed after
anesthesia is
administered.
A prophylactic
antibiotic is
given, and
the patient is
prepped and
draped in the
usual fashion.
The cervix of a retroverted uterus, especially one fixed by dense adhesions to the
cul-de-sac, is often difficult to visualize. No
attempt at insertion of the uterine manipulator should be made unless the cervix is
clearly visualized and brought into the center of the vaginal speculum.
The anterior lip of the cervix is then
grasped with a single-tooth tenaculum and
the uterus sounded carefully to determine
the length and the direction of the uterine
cavity. Among women with cervical stenosis, lachrymal duct dilators or small Pratt
dilators might be needed before sounding.
If severe cervical stenosis is suspected preoperatively, an overnight insertion of a vaginal prostaglandin suppository might help
soften the cervix and facilitate insertion of
the uterine manipulator.
Depending on the type of the manipulator used, the manipulator might be
hooked to the tenaculum (eg, the Pelosi)
or the tenaculum removed before inser-
COMPLICATIONS
Complications attributable to the use of
uterine manipulators include cervical lacerations, uterine perforation, laceration of
uterine vessels, retroperitoneal or intraperitoneal bleeding, perforation of the bowel,
rectum or bladder, ascending infection,
interruption of unsuspected intrauterine
pregnancy, and retention of part of the manipulator as a foreign body.
Complications are more likely to happen
among postmenopausal women with a stenotic cervix and women with retroverted
or soft uteri. The use of uterine manipulators is contraindicated among women
who have pyometra or distorted or altered
anatomy (eg, vaginal septum) precluding
visualization of the cervix, if intrauterine
ELTABBAKH
CONCLUSION
Uterine manipulators facilitate laparoscopic hysterectomy. The type of manipulator used will depend on the type of hysterectomy, patients characteristics, available
instruments, and surgeons preference.
The author reports no actual or potential
conflict of interest in relation to this article.
REFERENCES
1. Wu JM, Wechter ME, Geller EJ, Nguyen TV, Visco AG.
Hysterectomy rates in the United States, 2003. Obstet
Gynecol. 2007;110(5):1091-1095.
2. Farquhar CM, Steiner CA. Hysterectomy rates in the
United States 1990-1997. Obstet Gynecol. 2002;99(2):
229-234.
3. Ramirez PT, Frumovitz M, Dos Reis R, et al. Modified
uterine manipulator and vaginal rings for total laparoscopic radical hysterectomy. Int J Gynecol Cancer.
2008;18(3):571-575.
4. Sonoda Y, Zerbe M, Smith A, Lin O, Barakat RR,
Hoskins WJ. High incidence of positive peritoneal
cytology in low-risk endometrial cancer treated by
laparoscopically assisted vaginal hysterectomy.
Gynecol Oncol. 2001;80(3):378-382.
5. Eltabbakh GH, Mount SL. Laparoscopic surgery does
not increase the positive peritoneal cytology among
women with endometrial carcinoma. Gynecol Oncol.
2006;100(2):361-364.
6. Walker JL, Piedmonte MR, Spirtos NM, et al. Laparoscopy compared with laparotomy for comprehensive surgical staging of uterine cancer: Gynecologic
Oncology Group Study LAP2. J Clin Oncol. 2009;
27(32):5331-5336.
FOCUSPOINT
Although the
uterine
manipulator is
an essential
tool for the
surgeon
performing
laparoscopic
hysterectomy,
there are a
number of
attributable
complications.
In this issue...
Contraception
Bleeding Profiles
and