Zytel (R) 80g14ahsnc010
Zytel (R) 80g14ahsnc010
Zytel (R) 80g14ahsnc010
DuPont Zytel
nylon resin
PRELIMINARY DATA
Zytel 80G14AHS NC010 is a 14% glass fiber reinforced, toughened, high flow, heat stabilized polyamide 66
resin. It offers outstanding performance in injection molding applications.
Property
Test Method
Units
Value
DAM
Identification
Resin Identification
ISO 1043
PA66-IGF14
ISO 11469
>PA66-IGF14<
Mechanical
Stress at Break
ISO 527
MPa (kpsi)
110 (16.0)
Strain at Break
ISO 527
3.8
Tensile Modulus
ISO 527
MPa (kpsi)
5000 (725)
Flexural Modulus
ISO 178
MPa (kpsi)
4400 (640)
ISO 179/1eA
kJ/m2
13
ISO 75f
C (F)
ISO 11357-1/-3
C (F)
240 (464)
10C/min
263 (505)
Other
Density
ISO 1183
kg/m3 (g/cm3)
Molding Shrinkage
ISO 294-4
Normal, 2.0mm
Parallel, 2.0mm
1190 (1.19)
0.8
0.7
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23C unless otherwise stated.
The above data are preliminary and are subject to change as additional data are developed on subsequent lots.
The DuPont Oval Logo, DuPont, The miracles of science and Zytel are trademarks or registered trademarks of DuPont Company. Copyright 2005.
050713/050714
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.
plastics.dupont.com
1/2
Product Information
Units
Value
DAM
C (F)
285-305 (545-580)
C (F)
295 (565)
C (F)
50-100 (120-210)
C (F)
80 (175)
2-4
C (F)
%
80 (175)
<0.20
Property
Test Method
Processing
Contact DuPont for Material Safety Data Sheet, general guides and/or additional information about ventilation, handling, purging, drying, etc.
ISO Mechanical properties measured at 4.0mm, ISO Electrical properties measured at 2.0mm, and all ASTM properties measured at 3.2mm.
Test temperatures are 23C unless otherwise stated.
The above data are preliminary and are subject to change as additional data are developed on subsequent lots.
The DuPont Oval Logo, DuPont, The miracles of science and Zytel are trademarks or registered trademarks of DuPont Company. Copyright 2
050713/050714
The information provided in this data sheet corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new
knowledge and experience becomes available. The data provided fall within the normal range of product properties and relate only to the specific material designated;
these data may not be valid for such material used in combination with any other materials, additives or pigments or in any process, unless expressly indicated otherwise.
The data provided should not be used to establish specification limits or used alone as the basis of design; they are not intended to substitute for any testing you may need to
conduct to determine for yourself the suitability of a specific material for your particular purposes. Since DuPont cannot anticipate all variations in actual end-use
conditions DuPont makes no warranties and assumes no liability in connection with any use of this information. Nothing in this publication is to be considered as a
license to operate under or a recommendation to infringe any patent rights. DuPont advises you to seek independent counsel for a freedom to practice opinion on the intended
application or end-use of our products. Caution: Do not use this product in medical applications involving permanent implantation in the human body.
For other medical applications see "DuPont Medical Caution Statement", H-50102.