Ez Switch Setup Guide
Ez Switch Setup Guide
Ez Switch Setup Guide
December 5, 2008
EZSwitchSetup
Administrators Guide
European Headquarters
Brocade Communications Switzerland Srl
Centre Swissair
Tour B - 4me tage
29, Route de l'Aroport
Case Postale 105
CH-1215 Genve 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
Email: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Singapore Pte. Ltd.
30 Cecil Street
#19-01 Prudential Tower
Singapore 049712
Singapore
Tel: +65-6538-4700
Fax: +65-6538-0302
Email: apac-info@brocade.com
Document History
The following table lists all versions of the EZSwitchSetup Administrators Guide.
Document Title
Publication Number
Summary of Changes
Publication Date
53-1000121-01
First release
January 2006
53-1000195-01
September 2006
53-1000195-02
February 2007
53-1000441-01
June 2007
53-1000607-01
October 2007
53-1000607-02
March 2008
53-1000607-03
July 2008
53-1001193-01
November 2008
53-1001193-02
December 2008
Contents
Chapter 1
Introducing EZSwitchSetup
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overview of EZSwitchSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
EZSwitchSetup software and hardware requirements . . . . . . . . . . . . 2
Configuring Internet Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Supported switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Language support for EZSwitchSetup . . . . . . . . . . . . . . . . . . . . . . . . . 4
Chapter 2
Chapter 3
Appendix A
EZSwitchSetup Limitations
In this appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
General limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Index
vi
In this chapter
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Supported Hardware and Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Whats New in This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Additional Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Document Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Chapter 2, Setting Up Your Switch, describes how to set up your switch for the first time.
Chapter 3, Managing Your Switch, describes how to monitor and manage your switch using
the EZSwitchSetup Switch Manager.
vii
In those instances in which procedures or parts of procedures documented here apply to some
switches but not to others, this guide identifies exactly which switches are supported and which are
not.
Although many different software and hardware configurations are tested and supported by
Brocade Communications Systems, Inc. for Fabric OS 6.2.0, documenting all possible
configurations and scenarios is beyond the scope of this document; however, this document does
specify when procedures or parts of procedures apply only to specific switches.
This document does not support all Fabric OS versions. This document is specific to Fabric OS
6.2.0. To obtain information about an OS version other than 6.2.0, see the documentation specific
to that OS version.
viii
Document Conventions
This section describes text formatting conventions and important notices formats.
Text Formatting
The narrative-text formatting conventions that are used in this document are as follows:
bold text
italic text
Provides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code text
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is often all
lowercase. Otherwise, this manual specifically notes those cases in which a command is case
sensitive.
NOTE
A note provides a tip, emphasizes important information, or provides a reference to related
information.A note provides a tip, guidance or advice, emphasizes important information, or
provides a reference to related information.
ATTENTION
An Attention statement indicates potential damage to hardware or data.
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause
damage to hardware, firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
ix
Key terms
For definitions specific to Brocade and Fibre Channel, see the Brocade Glossary.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online
dictionary at http://www.snia.org/education/dictionary.
Additional Information
This section lists additional Brocade and industry-specific documentation that you might find
helpful.
Brocade resources
To get up-to-the-minute information, join Brocade Connect. Its free! Go to http://www.brocade.com
and click Brocade Connect to register at no cost for a user ID and password.
For practical discussions about SAN design, implementation, and maintenance, you can obtain
Building SANs with Brocade Fabric Switches through:
http://www.amazon.com
For additional Brocade documentation, visit the Brocade SAN Info Center and click the Resource
Library location:
http://www.brocade.com
Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric
OS firmware.
Best practice guides, white papers, data sheets, and other documentation is available through
the Brocade Partner Web site.
For additional resource information, visit the Technical Committee T11 Web site. This Web site
provides interface standards for high-performance and mass storage applications for Fibre
Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web
site:
http://www.fibrechannel.org
Switch model
Fabric OS version
Browser and Java Plug-in version
Error numbers and messages received
Java console window messages
Screen shots
supportSave command output
Detailed description of the problem, switch or fabric behavior immediately following
problem, and specific questions
*FT00X0054E9*
FT00X0054E9
The serial number label is located as follows:
Brocade 300 and 200E switches: On the nonport side of the chassis
Brocade 300, 4100, 4900, 5000, 5100, and 5300 switches: On the switch ID pull-out tab
located on the bottom of the port side of the switch.
3. World Wide Name (WWN)
Brocade 300 and 200E switches: On the nonport side of the chassis
Brocade 300, 4100, 4900, 5000, 5100, and 5300 switches: On the switch ID pull-out tab
located on the bottom of the port side of the switch.
Document Feedback
Because quality is our first concern at Brocade, we have made every effort to ensure the accuracy
and completeness of this document. However, if you find an error or an omission, or you think that
a topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your
comment, including the topic heading and page number and your suggestions for improvement.
xi
xii
Chapter
Introducing EZSwitchSetup
In this chapter
Overview of EZSwitchSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EZSwitchSetup software and hardware requirements . . . . . . . . . . . . . . . . . .
Supported switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Language support for EZSwitchSetup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
3
4
Overview of EZSwitchSetup
EZSwitchSetup is an easy-to-use graphical user interface application for setting up and managing
your switch. It has the following components:
FIGURE 1
EZSwitchSetup Components
Chapter 2, Setting Up Your Switch, describes how to use the EZSwitchSetup wizard and Switch
Configuration to set up and configure your switch for the first time. For additional information about
your switch, see the hardware reference manual included on the Brocade Documentation CD,
which ships with the switch.
Chapter 3, Managing Your Switch, describes how to use the Switch Manager to monitor and
manage your switch.
TABLE 1
Supported Platforms
Operating System
Browser
Java Plug-In
Firefox 2.0
1.6.0
1.6.0
1.6.0
1. Java Plug-in 1.5.0_06 is also supported, although Java Plug-in 1.6.0 is the only version that has been certified
and fully tested with this version of EZSwitchSetup.
Supported switches
FIGURE 2
Supported switches
You can use EZSwitchSetup with the following switches:
It must be connected to an Ethernet LAN that is accessible by the host. If it is not, the system
issues the message Page not Found.
It must be in a single-switch fabric. If your switch connects to another switch (if there is an
E_Port on the switch), you cannot manage the switch using EZSwitchSetup until you
disconnect the switch connection.
If there is an E_Port on the switch and if there is a zone conflict, then the fabric is segmented;
in this case, the switch is in a fabric by itself and EZSwitchSetup treats it as a single-switch
fabric.
English (default)
Brazilian Portuguese
French
German
Italian
Japanese
Korean
Simplified Chinese
Spanish
Traditional Chinese
When you launch EZSwitchSetup, the interface detects the operating system and language
environment and installs and displays the appropriate language. For example, if you set up the
switch using a German operating system, EZSwitchSetup installs the German language interface
and displays text, messages, and labels in that language.
If localization resources are not fully available in the user host environment, EZSwitchSetup uses
the default language, English.
Regardless of the local language, the following is displayed in English:
Chapter
In this chapter
Installing and running the EZSwitchSetup wizard . . . . . . . . . . . . . . . . . . . . . . 5
Configuring the switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Zoning selection options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Connecting devices and completing the setup . . . . . . . . . . . . . . . . . . . . . . . 19
FIGURE 3
EZSwitchSetup Installer
ATTENTION
The Linux installation requires root access.
FIGURE 4
1. You have the choice of using a serial connection or an Ethernet connection to your LAN to set
the IP address for the switch. Choose the method you want to use for your installation. You may
want to use the serial connection if it is not possible or not convenient to connect the host on
the same subnet as the switch. Otherwise, the Ethernet connection is generally more
convenient and preferred.
2. Click Next.
The Connect Cables screen is displayed (Figure 5).
FIGURE 5
Figure 6 shows the cables connecting to the Brocade Fibre Channel switch, setup computer,
Ethernet hub or switch, and network.
NOTE
Not all switches have their serial and Ethernet connectors in the same place as in Figure 6.
Refer to the hardware documentation to determine the correct placement of the serial and
Ethernet connections.
1
2
IOIOI
0
4
1
5
2
6
3
7
8
12
9
13
10
14
11
15
3
4
5
C
6
7
1
2
3
Brocade switch
Power cable
Ethernet hub or switch
Serial cable
FIGURE 6
5
6
7
Setup computer
Ethernet cable from hub to Brocade switch
Ethernet cable from setup computer to
Ethernet hub or switch
Cable connections
3. Connect the power cord to the switch and plug in to a power source.
The switch power and status LEDs display amber and then change to green, which usually
takes from one to three minutes. See your switch hardware manual for the location of the
LEDs.
4. Connect an Ethernet cable from the Brocade switch to the LAN you want to use for your
management connection through an Ethernet hub or switch. If you chose to use your Ethernet
connection for Set up in step 1, this is the connection you will use. If you chose the serial cable
connection in step 1, you should still connect the Ethernet cable so the Ethernet connection
will be available when you start the EZSwitchSetup manager.
5. If you are using a serial connection for set up, connect your setup computer to the serial port
on the switch, using the serial cable shipped with the switch. If you cannot locate the serial
cable that came with the switch, you will need to find one that has the appropriate connectors.
Do not use a null-modem cable. The serial connection settings are as follows.
6. Click Next.
EZSwitchSetup attempts to discover the switch. If your switch discovery fails, see Table 2 on
page 15 for details on how to recover your switch.
If you are using the serial connection, the Set Switch IP Address screen is displayed, and you
can go to step 7. You can now remove the serial cable from the switch, but keep it available in
case you lose your network connection, and need to revise any of the information you entered.
If you are using an Ethernet LAN connection, a Discover Switch screen is displayed (Figure 7).
FIGURE 7
a.
Brocade 200E switches: Look on the back (non-port) side of the chassis.
b.
From the Screen WWN drop-down list (Figure 7), choose the switchs WWN prefix numbers
and then enter the last six alphanumeric digits of your switchs WWN. Each two
alphanumeric digits must be separated by a colon.
c.
Click Next.
Brocade 300, 4100, 4900, 5000, 5100, and 5300 switches: Look on the switch ID
pull-out tab located on the bottom of the port side of the switch.
When EZSwitchSetup discovers the switch, it displays the discovered IP addresses (IPv4
and IPv6) on the screen (Figure 8).
FIGURE 8
10
NOTE
If you see a caution message saying the IP address is not reachable, always select Yes (the default
setting) under Do you want to assign a static IP to the Switch? Selecting No causes EZSwitchSetup
to continuously try to establish a Telnet session with the switch, which does not, as yet, have a
reachable IP address. If you have previously enabled DHCP on the switch (refer to Installing and
running the EZSwitchSetup wizard), you may select No.
d.
Click Next.
EZSwitchSetup attempts to log in using default credentials. If you have already changed
your admin password, you will be prompted to enter your new password. After the login is
processed, the Set Switch IP Address screen is displayed (Figure 9).
FIGURE 9
7.
Beginning at this step, the steps are the same for both serial and Ethernet connections. If you
are setting up the switch for the first time, the addresses shown are not valid. If you click Next
with these addresses in place, EZSwitchSetup returns an error screen. To set up IPv4
addresses, edit the address information on the Set Switch IP Address screen to create static
addresses appropriate for your LAN connection. To set up IPv6 addresses, enter the IPv6
address and Prefix in the spaces provided.
8. Click Next.
9. Go on to Confirming IP addresses.
11
Confirming IP addresses
The Confirm IP Address screen (Figure 10) is displayed after you have assigned IP addresses, using
either a serial connection or an Ethernet connection.
1. Check the displayed addresses carefully to be sure they are correct.
FIGURE 10
12
Enable and start the EZSwitchSetup Manager by clicking Continue with EZManager. If you
intend to use EZSwitchSetup Manager as your primary management program, you must
click Continue with EZManager at this time to enable and use EZSwitchSetup Manager.
FIGURE 11
13
If you click Continue with EZManager, A warning dialog box displays warning you that
EZSwitchSetUp only supports single switch fabrics (Figure 12).
FIGURE 12
14
TABLE 2
Discovery recovery
Symptom
Correction
15
FIGURE 13
FIGURE 14
16
Typical Zoning creates a port based zoning scheme based on the connections made on the
Configure Ports and Connect Devices screen (Figure 17). This zoning scheme creates a two
member zone for every possible pairing of H and S ports connected on the Configure Ports and
Connect Devices screen. This ensures that any host device connected to an H port is able to
communicate with any storage device connected to an S port.
Custom Zoning allows you to customize which initiators access which targets, and creates a
device-based zoning scheme based on your choices. The HBAs and storage devices should
already be connected to the switch. Custom Zoning provides a device accessibility matrix for
you to modify; it then automatically creates zones based on that matrix. Custom Zoning
supports only single-switch fabrics. If you select this option, when you click Next, the wizard
closes and the EZSwitchSetup Switch Manager application opens.
Advanced Zoning allows you complete customization of your zoning and should be used if you
are familiar with zoning and zoning practices. If you select this option, when you click Next, the
wizard closes and the Advanced Management application (Web Tools) opens. For specific
information about using Web Tools for zoning, see the Web Tools Administrators Guide.
.
FIGURE 15
17
Typical Zoning is the default and the following procedure directs you to select Typical Zoning. When
you select Typical Zoning, the wizard automatically configures the zones for you and shows you
how to connect the devices to the switch. You can change the zoning configuration later, as
described in Zoning management on page 41.
Specifying devices
On the Specify Devices screen (Figure 16), do the following.
1. Enter the number of HBA connections that you want to attach to the switch. Be sure to include
existing HBA connections, and any additional HBA connections you plan to make in the current
setup session. You can change this setting later if you want to add or remove HBA connections.
2. Enter the number of storage connections you want to attach to the switch. Be sure to include
existing storage connections, and any additional storage connections you plan to make in the
current setup session.You can change this setting later if you want to add or remove storage
connections.
EZSwitchSetup uses these values to verify that all your current and planned devices are
properly connected for the zoning scheme that will be created. Note that Typical zoning
ensures that every connected host device will be able to communicate with every connected
storage device.
3. Click Next. The Connect Devices screen is displayed (Figure 17 on page 20).
18
FIGURE 16
19
additional currently unoccupied ports for future HBA or Storage connections. These additional
reservations are also reflected in the zoning scheme, and are shown on the Display Devices screen
in the EZManager application to remind you where these additional devices can be connected. The
default reservation type is HBA.
FIGURE 17
When you click Next on the Configure Ports and Connect Devices screen, if Typical Zoning is used,
the final set of connection reservations shown on the screen is translated internally into a zoning
scheme that ensures that every correctly connected host device can communicate separately with
every correctly connected storage device. If this is not what you want (for example, if you want to
partition your devices so that each HBA can communicate with some storage devices but not
others), then you should re-run the Setup wizard and select Custom Zoning or Advanced Zoning
instead of Typical Zoning.
Use the following procedure to make the physical connections.
1. Install the small form factor pluggable (SFP) transceivers in the Fibre Channel ports shown
onscreen. (See Figure 18 on page 21).
20
a.
b.
Position and insert each SFP transceiver as required (right side up in the top row of ports
and upside down in the bottom row of ports) until it is firmly seated.
c.
IO
IO
IO
IO
1
4
4-01
1
2
Brocade switch
Open the SFP bale
FIGURE 18
3
4
Installing SFPs
2. Connect Fibre Channel cables from the switch to your host and storage devices. Ensure that
the physical connections are exactly as indicated on the Configure Ports and Connect Devices
screen.
a.
Remove any plastic protectors from the Fibre Channel cable ends, and position the cable
connector so that it is oriented correctly.
b.
Insert the cable connector into the SFP until it is firmly seated and the latching mechanism
clicks.
21
The Configure Ports and Connect Devices screen provides visual feedback as you cable
the switch. A green line indicates that the connection is correct, a red line indicates an
invalid connection, and a blue line indicates a missing connection.
.
ck
N: for ra 4 in.
TIO gth 13/6
EN rew lenm or
5m
ATT um scbe
im g to
tin
Max
un
mo
1
2
FIGURE 19
Brocade switch
3. Verify that the connections displayed on the Configure Ports and Connect Devices screen are
all green.
4. Click Next.
The Finish screen is displayed.
22
FIGURE 20
23
24
Chapter
In this chapter
Switch manager overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Launching the EZSwitchSetup Switch Manager . . . . . . . . . . . . . . . . . . . . . .
Viewing switch information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changing switch information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enable inactive ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Managing devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Zoning management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessing Web Tools for advanced management . . . . . . . . . . . . . . . . . . . . .
25
28
30
36
36
37
41
45
Monitor the switch, including port and field replacable unit (FRU) status
Manage custom zoning
Perform basic switch configurations
Add Ports On Demand (POD)
The Switch Manager works for a single-switch fabric only. It displays only the switch and associated
tasks, without fabric information.
Figure 21 shows an example of the initial Switch Manager screen for the Brocade 200E. For other
switches the window appearance may vary. The following sections describe the components of the
screen.
25
1
2
3
Task panel
Content Page
Status bar
FIGURE 21
3A Progress indicator
3B User name, IP address, and user role
Task panel
The left pane of the Switch Manager is the task panel, which displays all tasks. The tasks are
categorized by Switch, Devices, Zoning, and Miscellaneous.
The Switch tasks enable you to view the port information or switch information, enter into switch
setup, or add PODs by enabling inactive ports.
The Devices tasks enable you to view the devices attached to the switch, display the device
connections, and modify a device alias.
The Zoning tasks enable you to view the zoning on the device, edit the zoning, validate the zoning,
or restore the default fixed zoning.
The Miscellaneous tasks include refreshing the onscreen data, advanced management of the
switch, and logging out.
The switchs Port Information page is shown by default when Switch Manager launches.
26
Switch View
The Switch View displays the switch and status buttons across the top. The status buttons enable
access to each element listed.
Click the refresh icon under the Miscellaneous Tasks to update the information on the screen with
the current switch information. The display refreshes automatically each time you click a different
task in the task panel.
Content page
When you click an item in the task panel, the content for that item displays in the right pane of the
window. A content page may contain tabs, display information, launch a wizard, or display a dialog.
Figure 22 shows the information displayed from the Port Information tab, and shows a right click
menu that provides copy and export functions. Beginning with Fabric OS version 6.2.0, the right
click menu replaces the Export, Copy, and Search buttons used in earlier releases.
FIGURE 22
NOTE
You must accept the Brocade Certificate at the beginning of the login to EZSwitch Manager to enable
the functionality of Export and Copy.
Click Export Row or Export Table to save the information to a tab-delimited text file.
Click Copy Yes, Copy Row or Copy Table to copy the contents of the table in tab-delimited text
format that can be pasted into a spreadsheet. Copy Yes copies only the contents of the cell
where the mouse is clicked, Copy Row copies the entire row, and Copy Table copies the entire
table.
27
Status bar
The status bar, at the bottom of the window, is divided into the following sections:
Progress indicator
This is on the left side of the status bar. When Switch Manager is sending data to or retrieving
data from the switch, this indicator is animated.
or
https://10.77.77.77
2. Press Enter.
A Java Web Start dialog box is displayed, showing the download progress.
If this is the first time the application has been started, a Warning - Security dialog box is also
displayed.
3. If the Warning - Security dialog box is displayed, select Always trust content from this publisher
and click Run.
28
The Login dialog box is displayed. If there are other applications open when EZSwitchSetup
manager launches, the login dialog may be hidden. To view the login dialog, press Alt+Tab.
Logging in
When you log in, the EZSwitchSetup Switch Manager interface is launched if the switch is set up
and configured with EZSwitchSetup. If not, Web Tools is launched.
Switch Manager supports only single-switch fabrics. If your switch is connected to another switch,
Switch Manager displays a message and exits. You must disconnect the switch from all other
switches and relaunch EZSwitchSetup Switch Manager.
1. Type your user name.
2. Type the password.
3. Click OK.
A Switch Manager session is established, and the Switch View is displayed (Figure 23).
Logging out
You can end your Switch Manager session either by selecting Log Out in the Miscellaneous area of
the task panel, or by closing the browser window. All windows belonging to the session are
invalidated (after a short delay they become greyed out and unusable, but you must close them
manually), and the session is terminated.
29
FIGURE 23
The Switch View is a real-time view of switch and port status. The display is updated approximately
once every 15 seconds. From the display you can determine the following:
Fan status
Temperature status
Power supply status
Status and type of each port
Rectangles in the Fan, Temp, and Power buttons indicate overall status as follows:
30
FIGURE 24
FIGURE 25
Fan status
31
Figure 26 shows the Temperature view. The temperature view displays the number of
temperature sensors, their status, and the temperature in both Celsius and Fahrenheit.
FIGURE 26
Temperature status
Figure 27 shows the Power Supply view. The power supply view displays the number of power
supplies in the switch and their status.
FIGURE 27
32
Port status
The Switch View displays port graphics with blinking LEDs, simulating the physical appearance of
the ports. Two LEDs are associated with each port: one of the LEDs indicates port status; the other
indicates port speed. For LED information, see the hardware documentation for the switch you are
viewing.
The background color of the port icon indicates the port status, as follows:
Green (healthy)
Yellow (marginal)
Red (critical)
Gray (unmonitored)
If the entire port icon is blue, the port is buffer-limited. (A port is operating in buffer-limited mode
when the number of buffers allocated to the port is less than the number of buffers needed by the
port to utilize the port at full bandwidth.)
If a group of port icons is gray (unavailable), those ports are not licensed.
Figure 28 shows port icons and associated LEDs from a Brocade 4100 switch. The layout is similar
for all switches, but varies according to switch type.
The background color of the
port icon indicates port status.
FIGURE 28
Port and LED Status Color-Coded Information in the Port Icon in Switch View
Hover the cursor over the port icon to view the port number, port type, and port status, as shown in
Figure 29.
FIGURE 29
33
Hover the cursor over the LEDs to view details about the port state and port speed, as shown in
Figure 30.
FIGURE 30
FIGURE 31
34
FIGURE 32
Port number.
Port name.
State of the port.
Port type.
Status (health) of the port.
Indication of whether the port is licensed.
35
This is the same wizard that was launched the first time you set up the switch.
1. Click Setup under Switch in the task panel.
The Switch Configuration launches.
2. Follow the instructions in the wizard.
You can optionally change the switch name, switch time, and admin password. When
prompted, you must select a zoning configuration.
FIGURE 33
36
Managing devices
Managing devices
The Devices page displays the following information:
Whether the device is an HBA, an HBA plus storage, or a storage only device.
Device alias name, if one exists.
Vendor name.
Device name.
WWN of the device port.
Switch and port to which the device is connected.
1. Click View under Devices in the task panel to display a table of information for all of the
connected devices (Figure 34).
The entries in the table are based on the device WWNs, so a single physical device can have
more than one entry in the table. The device information can be viewed, copied, or exported.
FIGURE 34
Devices view
The table can be sorted by device type, port number, or vendor. You can refine sorting by using
the Ctrl key while selecting column headers. For example, if hold down the Ctrl key and select
Device Type and Port# shows port numbers associated with device types (Figure 35).
FIGURE 35
37
Managing devices
2. Select a row in the table to display additional information about the device.
3. Click View Details located at the top of the page. Figure 36 shows a Device Details example.
FIGURE 36
Device connections
EZSwitchSetup Switch Manager displays a graphical representation of the switch and the devices
that are connected to each port.
Click Display Connections under Devices in the task panel.
A graphical representation of the switch and connections displays, as shown in Figure 37. This is a
real-time display; the connections are updated automatically as you connect and disconnect HBAs
and storage.
If Typical Zoning is set on the switch, Switch Manager validates the connections and displays
whether the connections are valid or invalid.
38
Managing devices
FIGURE 37
FIGURE 38
39
Managing devices
FIGURE 39
After you have defined the device aliases, the aliases are displayed under Device Alias when you
select View under Devices (as in Figure 34). The device aliases are also displayed in the Zone
Access Map for Devices when you select View under Zoning (Figure 40).
FIGURE 40
40
Zoning management
Zoning management
Zoning enables you to partition your fabric into logical groups of devices that can access each
other. For example, you can partition your fabric into two zones, winzone and unixzone, so that your
Windows servers and storage do not interact with your UNIX servers and storage.
Zones can be configured dynamically. They can vary in size, depending on the number of
fabric-connected devices, and devices can belong to more than one zone. Because zone members
can access only other members of the same zone, a device not included in a zone is not available
to members of that zone.
Zone members may be specified by fabric location (domain, port index) only, or by device name
(node name or port WWN). Zones whose members are specified by fabric location are port-based,
and zones whose members are directly specified by device WWN are device-based. In port-based
zoning, all devices that are connected to ports that are in the same zone can communicate with
each other, and a device can join a zone simply by being connected to a member port. In
device-based zoning, devices are explicitly specified as members of the same zone. These devices
can communicate with each other regardless of where they are located in the fabric.
EZSwitchSetup creates zones for you automatically, based on your configuration choices in Setup.
If you chose Typical Zoning, a port-based zoning scheme was created. This zoning scheme
creates a two member zone for every possible pairing of H and S ports connected on the
Configure Ports and Connect Devices screen. This ensures that any host device connected to
an H port is able to communicate with any storage device connected to an S port. This remains
true even if you move a device, assuming you connect the device to the correct type of port (H
or S).
If you chose Custom Zoning, you created a device accessibility matrix during setup. The device
accessibility matrix creates a device-based zoning scheme. By default, every connected host
device can communicate with every connected storage device, as in typical zoning. You can
use the device accessibility matrix to selectively disallow communications between certain
devices, creating a device partitioning scheme that is enforced by zoning. Because custom
zoning is device-based, you may freely move your devices to different ports without affecting
accessibility relationships. If you add or permanently remove devices, you should reconfigure
the accessibility matrix.
If you chose Advanced Zoning, you were given direct access to the zoning database through
Web Tools, and you created a zoning scheme of your own. EZManager can validate and display
accessibility relationships based on your scheme, and it can replace your scheme with Typical
Zoning or Custom Zoning. If you want to edit your scheme, you must return to Setup and chose
Advanced Management to start Web Tools. For specific information about using Web Tools for
zoning, see the Web Tools Administrators Guide.
41
Zoning management
FIGURE 41
42
Zoning management
If no devices are connected to the switch, or if only storage devices or only HBAs are
connected, then the Switch Manager displays a message and the Edit HBA/Storage
Accessibility Matrix does not launch.
FIGURE 42
5. Clear the check boxes selectively until you have defined the access groups and accessibility
relationships you want in your zoning scheme.
6. When you are done making changes, click Next and the zoning Summary and Confirmation
screen is displayed (Figure 43). Use the Print button if you would like a printed record of the
zoning scheme.
7.
Click Finish to create the zoning scheme. Click Cancel if you do not want to create this zoning
scheme, and prefer to leave a previous scheme in place.
If you click Finish, allow time for the new scheme to be created. The Zone Access Map is
updated with any new aliases, and a Zone commit succeeded confirmation dialog box is
displayed.
8. Dismiss the confirmation dialog box. The Zone Access Map is updated to show the new
accessibility relationships.
43
Zoning management
FIGURE 43
44
45
46
Appendix
EZSwitchSetup Limitations
In this appendix
General limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
General limitations
Table 3 lists general EZSwitchSetup limitations, which apply to all browsers and switch platforms.
TABLE 3
Problem Area
Details
HTTP timeout
Very often, you may see the following message when you try to get data from a switch
or to send a request to the switch:
Failed to get switch response. Please verify the status
of your last operation and try again if necessary.
This indicates that an HTTP request did not get a response. The request was sent to
the switch, but the connection was down, probably caused by a temporary loss of the
Web server on the switch. Due to the nature of an HTTP connection, Switch Manager
will report this error after a 90-second default timeout.
In this case, verify the status of your last request, using Telnet to check related status,
or click the Refresh button in the Switch Manager to retrieve related data. If your
request did not get through to the switch, resubmit it. Executing a refresh from Switch
Manager retrieves a copy of switch data at that moment; the data you entered can be
lost if it had not already been committed to the switch.
47
General limitations
TABLE 3
48
Problem Area
Details
Loss of Connection
Occasionally, you may see the following message when you try to retrieve data from the
switch or send a request to the switch:
Switch Status Checking
The switch is not currently accessible.
The dialog title may vary, because it indicates which module is having the problem.
This is caused by the loss of HTTP connection with the switch, due to a variety of
possible problems. Switch Manager automatically tries to regain the connection. While
Switch Manager is trying to regain the connection, check if your Ethernet connection is
still functioning. If the problem is not with the Ethernet connection, wait for Switch
Manager to recover the connection and display the following message:
You will have to resubmit your request after closing this message.
If the temporary switch connection loss is caused by switch hot code load, or other
similar operation, the Switch Explorer you are currently running can be downloaded
from a different firmware version than the new one. In this case the following message
displays:
Switch connection is restored. The firmware version you are running is not in sync with
the version currently on switch. Close your browser and re-launch Webtools.
You must close Switch Manager and relaunch it to reopen the connection.
If you change the switch name using EZSwitchSetup or SNMP and then open a Telnet
window to verify the name change, the CLI prompt (for example, switch:admin>)
displays the previous name. The Telnet prompt cannot pick up the new switch name
until the switch is rebooted.
Workaround: To display the correct switch name in the CLI prompt after a switch name
update using EZSwitchSetup or SNMP, fastboot the switch.
Index
enabling ports, 34
ending sessions, 29
EZSwitchSetup
about, 25
installing, 5
launching, 27
B
browsers
limitations, 43
refresh frequency, setting, 2
supported, 2
C
changing switch information, 34
CIDR block, 11
closing sessions, 29
COM port is busy. setup computer, 16
configuring Internet Explorer, 2
connecting Fibre Channel cables, 21
connections, displaying, 36
contacting technical support, xvii
D
defining device aliases, 37
device aliases, defining, 37
device connections, displaying, 36
device information, displaying, 35
displaying
device connections, 36
device information, 35
port information, 32, 33
switch information, 33
zoning configuration, 38
F
Fan Status, 30, 31, 34
Fan, Temperature, and Power Supply Legend,
31
Fibre Channel Association, xvi
Fibre Channel cables, connecting, 21
G
getting help, xvii
H
hard zones, 38
hardware, supported, 3
help, xvii
HTTPS protocol, 27
I
inactivity timeout, 29
installing
EZSwitchSetup, 5
SFPs, 20
IPv6 address, 10, 11
49
security banner, 28
session management, 29
sessions, ending, 29
setting refresh frequency, 2
SFPs, installing, 20
soft zones, 38
support, contacting technical, xvii
supported languages, 4
supported switches, 3
Switch discovery failure, 15
switch does not power up, 16
switch does not respond to commands, 16
switch information, displaying, 33
Switch Manager
about, 25
launching, 27
switch monitoring, 29
switch name, changing, 34
switch requirements, 3
switch setup wizard, launching, 34
switch status, 30
switch time, changing, 34
switchs serial adapter does not work., 16
switches supported, 3
L
languages supported, 4
launching EZSwitchSetup, 27
LEDs, 32
limitations, 43
localization support, 4
logging in, 28
logging out, 29
M
monitoring the switch, 29
O
operating systems, supported, 2
P
passwords, changing, 34
platforms, supported, 2
port information, displaying, 32, 33
ports
LEDs, 32
status, 32
Ports On Demand, adding ports, 34
Power Supply status, 32
power supply status, 30, 34
R
refresh frequency, setting, 2
removing offline devices, 41
renaming device aliases, 37
requirements for EZSwitchSetup, 2
restoring default fixed zoning, 41
role-based access control, 28
50
T
technical support, xvii
Temperature Status, 31
temperature status, 30, 34
time, changing, 34
timeout, session, 29
V
validating zone configuration, 41
viewing
device connections, 36
device information, 35
port information, 33
port status, 32
switch information, 29, 31
zoning, 38
Z
zoning
about, 38
advanced zoning, 18, 40
changing configuration, 34
configuration, displaying, 38
configure zones, 18
connect devices, 20
custom zoning, 17, 39
editing, 40
hard zones, 38
restoring default typical zoning, 41
soft zones, 38
specify devices, 18
typical zoning, 17, 39
validating zone configuration, 41
zone access map, displaying, 38
51
52